B08_Attachment_6_Revised_Drawing_A03_0001.pdf

PDF 2 MB Posted

Attached to
PORE BENEVENGA RESIDENCE 157 RENOVATION
Solicitation number
140P8425R0005
Issued by

About this file

This document is a construction drawing for the Benevagna 157 Renovation project, prepared for the National Park Service, Charles Valley Ranches Historic District. The drawings provide detailed architectural profiles and roof plans for a building with multiple asphalt shingle roof sections totaling 678 square feet (540 ft2 + 138 ft2). The profiles include South, North, West, and East elevations, showing a blue-colored building with orange-toned windows and a light-colored roof. The drawing includes critical notes emphasizing that all dimensions are approximate, should be verified by the contractor, and that the visual representations may not exactly match final specifications for colors and materials.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TPO Roof (133 ft2)

TPO Roof (328 ft2)

Asphalt Shingle Roof

(540 ft2)

Asphalt Shingle Roof

(540 ft2)

Asphalt Shingle Roof

(138 ft2)

Asphalt Shingle Roof

(100 ft2)

Asphalt Shingle Roof

(194 ft2)

Owner

National Park Service Benevenga 157 Renovation

Dwg.No.Revisions Project Sheet Title Date Scale

6/20/25

DrawnChecked

JPN

Job No.

JPN

Olema Valley Ranches Historic District 8165 Shoreline Highway (Highway 1) Bolinas, CA 94924

National Park Service Point Reyes National Seashore 1 Bear Valley Road Point Reyes Station, CA 94956

Notes

Do not scale the drawings. Contractor shall verify all dimensions and quantities. All dimensions and quantities provided or indicated are approximate. Original Sheet

Size Ansi D (22"x34")

196824

PMIS #Construction Drawings Profiles & Roof Plan

A03 284751

North

1.

2.

3.

4.

Profile and Roof Notes:

All dimensions and measurements provided herein are approximate and provided for reference. All dimensions and measurements should be verified by the contractor. Drawings are representative.

Drawings are for reference and supplement the specifications. Not all proposed final condition work described in the specifications is explicitly indicated in the drawings.

Profiles shown approximate the final condition.

Colors and finishes shown do not represent acutal colors and finishes. See specifications for actual materials and colors.

1 R01 - Roof Detail

2 P01 - South Profile

3 P02 - West Profile

4 P03 - North Profile

5 P04 - East Profile

Date Description Revision Number

A01 - Floorplan - Exisiting & Demo
A02 - Floorplan - Proposed
A03 - Profiles & Roof Plan
A04 - Lighting Plan

File details come from the government source that posted it. Updated .