Attachment_B_Specifications_and_Photos.pdf

PDF 1 MB Posted

Attached to
MORA-REPLACE GARAGE DOORS N101 N201
Solicitation number
140P8325Q0052
Issued by

About this file

This document is an Attachment to a Statement of Work (SOW) for the Replacement of Overhead Garage Doors at Mount Rainier National Park for buildings N101 and N201, located in the Nisqually Entrance Historic District. The project involves replacing garage doors while maintaining the historic integrity of two contributing structures: N101 (a 1915 superintendent's residence) and N201 (a 1934 six-bay utility and equipment garage). The work must comply with multiple preservation standards, including Section 106 of the National Historic Preservation Act, ensuring that the new doors match the original National Park Service Rustic architectural style with wood-clad, windowless panels in natural-tone finishes.

The project includes comprehensive documentation and strict guidelines for implementation, covering historic preservation, environmental conditions, contractor safety, and security upgrades. Key requirements include no structural modifications to the buildings, using removable fasteners, coordinating staging in environmentally sensitive areas, and following OSHA safety protocols. The performance period is from August 1, 2025, to December 31, 2025, with specific attention to preserving the buildings' architectural characteristics while improving functionality and security of the garage doors. The project is part of the Mount Rainier National Park's Facilities Maintenance Division efforts to maintain mission-critical infrastructure while respecting historical significance.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Mount Rainier National Park Facilities Maintenance Division

Attachment to Statement of Work (SOW) Replacement of Overhead Garage Doors – N101 & N201

PMIS Project No. 323461 Performance Period: August 1, 2025 – December 31, 2025

Prepared by: Frances Holmgren, Facilities Operations Specialist Date: July 10, 2025

This attachment package supports the Statement of Work by providing comprehensive documentation required for compliance, historic preservation, and project justification. It includes essential records verifying the eligibility of buildings N101 and N201 as contributing resources. Photographic, architectural, and operational evidence demonstrates the need for replacement and security upgrades. Each attachment is aligned with Section 106 compliance and NPS management policies. This set ensures that work meets preservation standards while supporting the mission-critical use of park infrastructure.

Table of Contents

• Attachment A – Historic Snapshot: N101 & N201

• Attachment B – Photo Documentation Log

• Attachment C – NRHP Form (Nisqually Entrance District)

• Attachment D – NRO Inventory Forms

• Attachment E – Lock Evaluation & Security Notes

• Attachment F – Site Map: Nisqually Housing Area

• Attachment G – Preservation Compliance & Code Summary

• Attachment H – Environmental Conditions & Staging

• Attachment I – Contractor Safety Plan Summary

Attachment A – Historic Snapshot: N101 & N201

Buildings N101 and N201 are contributing resources in the Nisqually Entrance Historic District, listed on the National Register of Historic Places in 1991 (NRHP Ref. No.

91000172).

• N101, constructed in 1915, served as the Superintendent’s residence and reflects early administrative planning in the park.

• N201, built in 1934 by the Civilian Works Administration, remains in its original use as a six-bay utility and equipment garage.

Both structures retain defining characteristics of the National Park Service Rustic architectural style including wood siding, gabled cedar-shingle roofs, and minimal ornamentation. They exemplify the park’s 20th-century development and operational continuity.

These buildings not only remain structurally intact, but their continued use in support of park operations further demonstrates the relevance of their original design. This attachment validates the need for preservation-sensitive door replacements that ensure operational continuity while respecting architectural legacy. The historical integrity and location within the historic district underscore the necessity for a carefully scoped project compliant with federal preservation guidelines.

Attachment B – Photo Documentation Log

A comprehensive set of photos documents:

• Exterior and interior views of all garage bays

• Condition of existing door panels, tracks, locking hardware

• Environmental impacts such as water intrusion, moss, and wear patterns

• Surrounding structural context including vegetation, access roads, and siding

The photographs reinforce the project’s necessity. Visual records show wear from decades of use, deferred maintenance, and environmental exposure common in high-elevation, high-moisture locations. Damage to lock systems and weathered panel materials highlight vulnerability to theft, wildlife intrusion, and material degradation—all of which compromise secure storage for park vehicles and tools essential to ranger and maintenance duties.

Attachment C – NRHP Form (Nisqually Entrance District)

The NRHP nomination form outlines the historic context, construction history, and architectural integrity of both N101 and N201.

It substantiates their inclusion as contributing structures and confirms their preservation significance under:

• Criterion A – early park administration and federal development

• Criterion C – Rustic style architecture employing local materials

The nomination documentation describes how park structures were intended to harmonize with the surrounding environment and provide minimal visual disruption. This foundation mandates that any intervention—such as garage door replacement—uphold those design principles. Reference to this form substantiates the design approach selected for this SOW and confirms compliance with preservation responsibilities.

Justification: This form serves as the federal basis for Section 106 review and treatment scope.

While it does not contain prescriptive work details, it provides the official framework for evaluating the appropriateness of all proposed modifications.

Attachment D – NRO Inventory Forms

The NPS Cultural Resources Division inventory forms offer detailed architectural descriptions, historic background, materials analysis, and modifications to both structures.

• N101: This 1½-story residence, built in 1915, features a steeply pitched gabled roof with cedar shingles, overhanging eaves, and a large front veranda originally supported by whole log columns. Though modest in size, its log-framed structure and thoughtful craftsmanship reflect the early philosophy of harmonizing architecture with the natural setting. With cedar siding stained in deep brown and a floor plan that once housed the superintendent and his family, the building still communicates its original role as a year-round operational hub.

• N201: Constructed in 1934 by the Civilian Works Administration, this elongated, low-profile garage served as a utilitarian core of ranger and maintenance operations.

Its six wood-clad overhead doors open into individual bays, framed by rough-sawn siding and a saltbox-style gable roof. While simple in form, the structure is visually unified with the park’s rustic design palette and has remained nearly unchanged in plan and appearance since its inception.

Code Reference: NPS Cultural Resource Management Guidelines (DO-28), FMSS documentation standards, and SOI Standards for evaluating alterations.

Justification: Inventory records establish physical parameters for what constitutes contributing features, guiding the limits of scope work such as door replacement.

These detailed architectural profiles support decisions on materials, finish, and installation approaches that preserve historic integrity.

Attachment E – Lock Evaluation & Security Notes

Current locks are weathered, misaligned, or no longer functional. Several garage bays have no lockable features, presenting vulnerabilities to unauthorized entry, wildlife access, and equipment loss.

Recommendations:

• Install new commercial-grade matching keyed entry locks rated for exterior security

• Locks to comply with NPS Facility Security Guidelines and FMSS records

• Ensure locks align with ADA and egress codes per NFPA 101 Life Safety Code

Code Reference: NFPA 101, NPS Risk Management Program Manual, DOI Access Control Standards

Justification: Modernized locks increase security without harming historic material. All installations shall be surface-mounted and reversible.

Attachment F – Site Map: Nisqually Housing Area

This site plan shows:

• Proximity of N101 and N201 to roadways, residential areas, and support facilities

• Staging constraints due to one-lane roads and vegetation buffers

• Limits on vehicle turnaround and delivery truck access

Code Reference: NPS Transportation Planning Manual, OSHA 1926.21 site safety and access control

Justification: A clearly defined site map ensures contractor access routes are environmentally sensitive and safety-compliant. It supports pre-mobilization planning and avoids disruption to nearby housing operations.

Attachment G – Preservation Compliance & Code Summary Policy/Standard Description Application to N101 & N201

Section 106, NHPA (54 U.S.C. § 306108)

Requires federal agencies to evaluate the effects of undertakings on historic properties.

Guides consultation, documentation, and ensures adverse effects are avoided or mitigated.

36 CFR Part 800 Establishes procedures for historic property evaluation and treatment.

Applies to garage door replacement—requires compliance with effect findings.

SOI Standards – Standard #2

“Historic character shall be retained and preserved.”

Doors must match original location, form, and design intent; no structural changes.

NPS Management Policies 2006, 5.3.5.4

Replacement must match existing in composition, color, and texture.

Requires wood-clad doors with natural-tone finish; windowless for security and compatibility.

Director’s Order 28

(DO-28)

Defines how cultural resources are managed during projects.

Provides project planning guidance to avoid impact on contributing structures.

Preservation Brief 14 Addresses new exterior features and compatibility.

Ensures replacement doors maintain architectural rhythm and do not overpower facade.

Preservation Brief 47 Provides maintenance guidance for small historic buildings.

Recommends reversible repair techniques and preservation of weather-exposed elements.

EPA VOC Standards Regulates allowable chemical content in construction coatings.

Ensures all paints/sealants used on new doors are environmentally compliant.

NEC 2023

Governs electrical safety including tools/lift equipment.

Any temporary electrical use must meet NEC grounding and circuit protection requirements.

Mitigation & Preservation Measures Purpose

No framing or structural modification allowed to bay openings Preserves historic openings and avoids irreversible damage

Retain and clean existing overhead tracks—do not replace Maintains original operational components with minimal disturbance

Use removable fasteners and non-destructive mounting hardware Ensures work is fully reversible and protects historic material integrity

New doors will be solid-panel wood or composite, without windows, finished in Rustic-compatible tones

Matches historic appearance and meets NPS Rustic aesthetic standards

Justification: This replacement project balances life-safety upgrades and functional use with architectural preservation. By adhering to NPS policy and preservation briefs, the park avoids adverse effects, meets federal compliance obligations, and maintains the historic integrity of two valuable assets within the Nisqually Entrance Historic District.

Attachment H – Environmental Conditions & Staging

• Work occurs in a sensitive forested zone near historic structures

• No soil excavation or vegetation removal permitted

• Debris must be removed daily to prevent wildlife attraction

Staging Area:

• Contractor must coordinate staging near N201’s southern side away from pedestrian areas

• No overnight material storage outside sealed containers

Code Reference: NEPA (42 U.S.C. § 4321), NPS Director’s Order 12, and MORA Environmental Management Policy

Justification: Compliance with environmental standards preserves natural resources, limits impact on wildlife, and aligns with MORA’s sustainability goals.

Attachment I – Contractor Safety Plan Summary

• All contractors shall comply with OSHA 1926 Subpart E and F for personal protective equipment and signage

• Work zones must be cordoned off with high-visibility tape and signage

• Fall protection required if ladders or work exceed 6 feet

• First-aid kit and fire extinguisher must be on-site at all times

Code Reference: OSHA 1926, NPS Safety Handbook, DOI Operational Risk Management Guidelines

Justification: Ensures life-safety compliance for contractors and staff working near garage bays during installation. Required for liability and contract approval.

Document Certification

This attachment document has been prepared in accordance with all applicable laws, policies, and guidelines governing National Park Service projects involving historic properties. It supports compliance with Section 106 of the NHPA, environmental and safety policies, and procurement planning standards under the FAR and DOI guidelines.

All information contained herein is accurate, complete, and reviewed for alignment with:

• 2800 DM (Departmental Manual – Acquisitions)

• DOI PRISM Submission Requirements

• NPS Cultural Resource and Facility Management Protocols

File details come from the government source that posted it. Updated .