B08_Solicitation_-_Att_11_-_Narrative_of_Changes_0003.pdf
PDF 172 KB Posted
- Attached to
- Pullman NHP - Renovation and Build-out
- Solicitation number
- 140P6226B0002
About this file
This is Addendum No. 1 to bidding documents for the Administration Clock Tower Building 2nd & 3rd Floor Remodel project (TSA Project No. 09064.001), issued by The Schemmer Associates on August 7, 2026. Bidders must acknowledge receipt of this addendum on the Bid Form or risk disqualification. The addendum comprises five pages of written items, zero pages of revised specifications, and four pages of revised full-size drawings. Prior manufacturer approvals are valid only for bidding purposes; final approval requires submittal of product data, shop drawings, and completed Substitution Request forms to the Architect for official review.
The addendum contains specification revisions and clarifications across multiple disciplines. Architectural changes include revised countertop material specifications for Wilsonart Bluestone with detailed performance requirements, glazing stop specifications for flush wood doors with mitered corners, removal of section 142100-1.02.C, and revised door hardware specifications for three hardware groups (Nos. 05, 08, and 13) detailing hinges, locks, cylinders, closers, and electric strikes for specific doors. Mechanical revisions remove cross-references to non-applicable sections in hydronic systems, natural gas piping, and HVAC controls. Fire protection removes a paragraph from the general duty valves section. Electrical modifications delete a sentence referencing Section 27 15 00. Drawing revisions include roofing general notes on G-100, revised door hardware on Sheet A-301, updated structural codes reflecting IBC 2024 on Sheet S 00, and a new slab detail on Sheet S 102. Civil and plumbing sections contain no changes.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
August 7, 2026 Addendum No. 1 - 1 TSA Job #09258.009
DATE: August 7th, 2026
FROM: The Schemmer Associates
Architects - Engineers 1840 NW 118th St. Suite 110 Clive, Iowa 50325 Phone: (515) 419-2221
TO: Prospective Bidders and Plan Holders
RE: Addendum No. 1 to the Bidding Documents for:
Administration Clock Tower Building 2nd & 3rd Floor Remodel TSA Project No. 09064.001
This addendum is issued by the Architect to the Contractor. This Addendum shall be made a part of the Contract Documents. Acknowledge receipt of this Addendum shall be provided on the Bid Form. Failure to do so may subject Bidder to disqualification.
Prior approval of manufacturers is general approval only for bidding purposes. Final approval of the products is contingent upon the submittal of product data and/or shop drawings which will have to meet the specific design requirements and the specifications, along with a completed Substitution Request form provided in the Specifications returned to the Architect for official approval.
This addendum consists of five (5) pages of written addendum items, zero (0) pages of revised specifications, and four (4) pages of revised full-size drawings.
Sincerely, THE SCHEMMER ASSOCIATES INC.
August 7, 2026 Addendum No. 1 - 2 TSA Job #09258.009
PROJECT MANUAL
GENERAL
Item No. SG-1
RESPONSE to Question #7: Sections 05 50 00, 06 20 00, 08 11 00, 08 14 00, 08 31 00, 09 90 00, 09 91 13, 21 12 00, 22 05 13, 23 05 13, 23 05 16, 23 09 34, 23 25 00, 23 33 19, 26 05 19.13, 26 05 36, 26 05 73, 27 15 00, and 33 01 10.58 are not applicable to this project. Section 03 30 00 is located on the structural drawing sheets.
CIVIL - None
ARCHITECTURAL
Item No. SA-1
RESPONSE to Question #8:
REVISE Specification Section 06 41 00 Architectural Woodwork, Paragraph 2.04_D: Countertops:
Wilsonart Bluestone 9074EA or approved equal Composition: Acrylic resins, fire-retardant mineral fillers, and proprietary coloring agents. Through-the-body color for full thickness of sheet material.
Tensile Strength: [6800 psi]; ASTM D 638 Flexural Strength: [10,000 psi]; ASTM D 790 Thermal Expansion Coefficient: 1.37 x 105 in./in.oF; ASTM D 696.
Impact Resistance: [144 in.] drop with no fracture; NEMA LD-3, Method 3.8 Stain Resistance: Pass; ANSI Z 124.3, modified. 12. Wear and Cleanability: Pass; ANSI Z 124.3.
Moisture Absorption: Less than 0.25 percent; ASTM D 570, long term
Accessory materials Joint Adhesive: Methacrylate-based adhesive for chemically bonding solid surfacing seams. Color complementary to solid surfacing sheet material. UL 2818 GREENGUARD Gold certified and complies with SCAQMD Rule 1168.
Siliconized Acrylic Sealant: Siliconized acrylic latex sealant. For general applications to fill gaps between countertops and at terminating substrates. Complies with ASTM C 834, Type OP, Grade NF, and SCAQMD Rule 1168. 1.
Item No. SA-2
RESPONSE to Question #10:
REVISE Specification Section 08 14 16 Flush Wood Doors, Paragraph 2.07_D: Glazing Stops: Wood, of same species and finish as door facing. Provide flush square/kerfed profile with mitered corners.
Item No. SA-3
RESPONSE to Question #7:
Remove paragraph 142100-1.02.C
August 7, 2026 Addendum No. 1 - 3 TSA Job #09258.009
Item No. SA-4
RESPONSE to Question #9:
REVISE Specification Section 08 71 00 Door Hardware.
Hardware Group No. 05
For use on Door #(s):
Provide each SGL door(s) with the following:
QTY DESCRIPTION CATALOG NUMBER FINISH MFR
3 EA HINGE 5BB1 4.5 X 4.5 652 IVE
1 EA MORTISE STOREROOM
LOCK
PBCN 8805FL LC 626 YAL
1 EA MORTISE CYLINDER 2153 x BLDG STD KEYWAY 626 YAL
1 EA OH STOP & HOLDER 100F 630 GLY
1 EA SOUND SEAL 188SBK PSA BLK ZER
1 EA ELECTRIC STRIKE 1006 630 HES
Hardware Group No. 08
For use on Door #(s): Remove Door 211 from Group. No. 7
211, 217
Provide each SGL door(s) with the following:
QTY DESCRIPTION CATALOG NUMBER FINISH MFR
3 EA HINGE 5BB1 4.5 X 4.5 652 IVE
1 EA MORTISE STOREROOM
LOCK
PBCN 8805FL LC 626 YAL
1 EA MORTISE CYLINDER 2153 x BLDG STD KEYWAY 626 YAL
1 EA SURFACE CLOSER 4040XP REG OR PA AS REQ 689 LCN
1 EA WALL STOP WS401/402CVX 626 IVE
3 EA SILENCER SR64 GRY IVE
1 EA ELECTRIC STRIKE 1006 630 HES
Hardware Group No. 13
For use on Door #(s): Existing doors at egress stairs floors 1, 2 & 3. Existing door, frame, and hardware to remain.
S2, S3, N1, N2, N3
1 EA ELECTRIC STRIKE 9500 OR 1006 (VERIFY EXISTING) 630 HES
1 EA DOOR POSITION SWITCH DPS-W BLK SEC
STRUCTURAL - None
August 7, 2026 Addendum No. 1 - 4 TSA Job #09258.009
FIRE
Item No. SF-1, Section 210523 – General Duty Valves for Water-Based Fire-Suppression Piping
ANSWER: Remove paragraph 3.02.A.1
PLUMBING – None
MECHANICAL
Item No. SM-1, Section 232123 – Hydronic Pumps
ANSWER: Remove reference to 230513 from section 2.04.E.1 ANSWER: Remove reference to 230934 from section 2.02.B.2
Item No. SM-2, Section 231123 – Facility Natural-Gas Piping RESPONSE to Question #7:
ANSWER: Remove reference to 230516 from section 3.03.E
Item No. SM-3, Section 232113 – Hydronic Piping RESPONSE to Question #7:
ANSWER: Remove reference to 232500 from section 3.01.F
Item No. SM-4, Section 233100 – HVAC Ducts and Casings RESPONSE to Question #7:
ANSWER: Remove reference to 233319 from section 2.01.C
Item No. SM-5, Section 232114 – Hydronic Specialities RESPONSE to Question #11:
ANSWER: Remove sections 2.05.2.a and 2.025.2.b and replace with the following:
2.05.2.a – Maximum intermittent offset from centerline is ¾”. Maximum permanent offset from centerline is 1”.
Item No. SM-6, Section 230913 – Instrumentation and Control Devices for HVAC RESPONSE to Question #30:
ANSWER: Remove section 1.04
ELECTRICAL
Item No. SE-1, Section 281300 Para. 2.12(A)(1a.) - Delete last sentence with reference to Section 27 15 00.
August 7, 2026 Addendum No. 1 - 5 TSA Job #09258.009
DRAWINGS
GENERAL
RESPONSE to Question #61:
Item No. DG-1, Sheet G-100 ANSWER: Roofing General Notes have been provided in the General Notes section providing guidance on new roof penetrations and flashings.
CIVIL- None
ARCHITECTURAL
RESPONSE to Question #9:
Item No. DA-1, Sheet A-301 Revised door hardware
STRUCTURAL
RESPONSE to Question #19:
Item No. DS-1, Sheet S 00 Codes adjusted to reflect use of IBC 2024.
RESPONSE to Question #21:
Item No. DS-2, Sheet S 102 Added new slab at existing slab detail 8/S102.
PLUMBING - None
MECHANICAL - None
ELECTRICAL - None
END OF ADDENDUM NO. 1
File details come from the government source that posted it. Updated .