Atch_2_to_Amd_1_Report_0001.pdf

PDF 1 MB Posted

Attached to
Replace Shake Roof-TIMU Federal contract opportunity
Solicitation number
140P5424R0004
Issued by
Department of the Interior National Park Service Southeast Region

About this file

This file is an attachment related to an amendment for a federal solicitation to replace shake roofing at Timuquana National Park. The solicitation number is 140P5424R0004 and is being issued by the Department of the Interior National Park Service Southeast Region. Offerors are requested to propose replacing the existing shake roof at Timuquana National Park. The solicitation amendment provides additional details on the scope of work, which involves removing all existing wood shake roofing, underlayment, drip edge and accessories. Offerors should price the project to install new 30-year architectural shingles including underlayment, drip edge and other accessories in accordance with the specifications. Proposals are due by April 15th and the contract is expected to be awarded by May 1st.

View the file

Other files for this federal contract opportunity

Other files attached to Replace Shake Roof-TIMU, newest first.
File Type Posted
Sol_140P5424R0004_Amd_0003.pdf PDF
Sol_140P5424R0004_Amd_0002.pdf PDF
Sol_140P5424R0004_Amd_0001.pdf PDF
Atch_1_to_Amd_1_QandAs_0001.pdf PDF
Sol_140P5424R0004.pdf PDF
Atch_4_Site_Visit_Info.pdf PDF
Atch_1_SOW.pdf PDF
Atch_5_Past_Perf_Questionnaire.pdf PDF
Atch_2_DOL_DBA_WD.pdf PDF
Atch_3_Drawings_and_Photos.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

November 30, 2018

Dear Order No:

RE:

Analytical Environmental Services, Inc. received samples on for the analyses presented in following report.

No problems were encountered during the analyses. Additionally, all results for the associated

Quality Control samples were within EPA and/or AES established limits. Any discrepancies associated with the analyses contained herein will be noted and submitted in the form of a project Case Narrative.

AES’s accreditations are as follows:

-NELAP/State of Florida Laboratory ID E87582 for analysis of Non-Potable Water, Solid & Chemical

Materials, Air & Emissions Volatile Organics, and Drinking Water Microbiology & Metals, effective

07/01/18-06/30/19.

State of Georgia, Department of Natural Resources ID #800 for analysis of Drinking Water Metals, effective

07/01/18-06/30/19 and Total Coliforms/ E. coli, effective 04/25/17-04/24/20.

-AIHA-LAP, LLC Laboratory ID: 100671 for Industrial Hygiene samples (Organics, Metals, PCM Asbestos, Gravimetric), Environmental Lead (Paint, Soil, Dust Wipes, Air), and Environmental Microbiology (Fungal)

Direct Examination, effective until 11/01/19.

These results relate only to the items tested. This report may only be reproduced in full.

If you have any questions regarding these test results, please feel free to call.

Sincerely, Project Manager

1811M21

Morgan Baird National Park/Timucuan Preserve

11676 Palmetto Ave Jacksonville FL 32226

Main House Painting

Chris Pafford

11/26/2018 4:25:00 PM

Morgan Baird:

Analytical Environmental Services, Inc Date: 30-Nov-18

National Park/Timucuan Preserve TOTAL LEAD IN PAINT (NIOSH 7082)

Matrix:

Lab Order: 1811M21

Paint

Date Received:

Project: Main House Painting

11/26/2018 4:25:00 PM

Client:

Reporting

Limit AnalystUnitsResultClient Sample IDLaboratory ID

Date

Analyzed

Date

Collected DF Qual

1811M21-001A MH#1 NW Corner 2.33 wt% 0.274 29.74 11/19/2018 11/28/2018 AS

1811M21-002A MH#2 South Face East Side 0.0179 wt% 0.00962 1 11/19/2018 11/28/2018 AS

1811M21-003A MH#3 East Window 0.0386 wt% 0.00917 1 11/19/2018 11/28/2018 AS

1811M21-004A KH#1 South Face 1.34 wt% 0.206 21.17 11/19/2018 11/28/2018 AS

1811M21-005A KH#2 West Doorway Overhang 0.588 wt% 0.108 11.12 11/19/2018 11/28/2018 AS

1811M21-006A KH#3 West Window Frame 0.373 wt% 0.00981 1 11/19/2018 11/28/2018 AS

Qualifiers: BRL - Not Detected at the Reporting Limit DF - Dilution Factor

B - Analyte detected in the associated Method Blank

SAMPLE/COOLER RECEIPT CHECKLIST

1. Client Name: AES Work Order Number:

2. Carrier: FedEx UPS USPS Client Courier Other

Yes No N/A Details Comments

3. Shipping container/cooler received in good condition? damaged leaking other

4. Custody seals present on shipping container?

5. Custody seals intact on shipping container?

6. Temperature blanks present?

7.

Cooler temperature(s) within limits of 0 6 C? [See item 13 and 14 for temperature recordings.]

Cooling initiated for recently collected samples / ice present

8. Chain of Custody (COC) present?

9. Chain of Custody signed, dated, and timed when relinquished and received?

10. Sampler name and/or signature on COC?

11. Were all samples received within holding time?

12. TAT marked on the COC? If no TAT indicated, proceeded with standard TAT per Terms & Conditions.

13. Cooler 1 Temperature C Cooler 2 Temperature C Cooler 3 Temperature C Cooler 4 Temperature C

Cooler 5 Temperature C Cooler 6 Temperature C Cooler 7 Temperature C Cooler 8 Temperature C

15. Comments:

I certify that I have completed sections 1 1 (dated initials).

Yes No N/A Details Comments

16. Were sample containers intact upon receipt?

17. Custody seals present on sample containers?

18. Custody seals intact on sample containers?

19. Do sample container labels match the COC?

incomplete info illegible no label other

20. Are analyses requested indicated on the COC?

21. Were all of the samples listed on the COC received?

samples received but not listed on COC samples listed on COC not received

22. Was the sample collection date/time noted?

23. Did we receive sufficient sample volume for indicated analyses?

24. Were samples received in appropriate containers?

25. Were VOA samples received without headspace (< 1/4" bubble)?

26. Were trip blanks submitted? listed on COC not listed on COC

27. Comments:

I certify that I have completed sections 1 27 (dated initials).

Yes No N/A Details Comments

28. Have containers needing chemical preservation been checked? *

29. Containers meet preservation guidelines?

30. Was pH adjusted at Sample Receipt?

I certify that I have completed sections 28 30 (dated initials).

Clear Save as

National Park Service Timucuan Preserve 1811M21

AMBIENT

14.

AB 11/26/18

This section only applies to samples where pH can be checked at Sample Receipt.

AB 11/26/18

* Note: Certain analyses require chemical preservation but must be checked in the laboratory and not upon Sample Receipt such as Coliforms, VOCs and Oil & Grease/TPH.

AB 11/26/18

Checklist 6.9.17 Rev 2 Locked

30-Nov-18Date:Analytical Environmental Services, Inc

Client:

BatchID:Workorder:

Project Name:

ANALYTICAL QC SUMMARY REPORT

Main House Painting

1811M21

National Park/Timucuan Preserve

270645

RPT Limit QualAnalyte Result SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit

SampleType: BatchID: Analysis Date: Seq No:TestCode: 270645MBLK 11/28/2018TOTAL LEAD IN PAINT by NIOSH 7082

Units: Prep Date:Sample ID: Client ID: Run No:wt% 11/28/2018 385562MB-270645

8612480

Lead 0.0100BRL

RPT Limit QualAnalyte Result SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit

SampleType: BatchID: Analysis Date: Seq No:TestCode: 270645LCS 11/28/2018TOTAL LEAD IN PAINT by NIOSH 7082

Units: Prep Date:Sample ID: Client ID: Run No:wt% 11/28/2018 385562LCS-270645

8612509

Lead 0.02000.6574 0.6010 109 80 120

RPT Limit QualAnalyte Result SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit

SampleType: BatchID: Analysis Date: Seq No:TestCode: 270645MS 11/28/2018TOTAL LEAD IN PAINT by NIOSH 7082

Units: Prep Date:Sample ID: Client ID: Run No:wt% 11/28/2018 3855621811K89-001AMS

8612483

Lead 0.009380.04906 0.0469 105 75 125

RPT Limit QualAnalyte Result SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit

SampleType: BatchID: Analysis Date: Seq No:TestCode: 270645MSD 11/28/2018TOTAL LEAD IN PAINT by NIOSH 7082

Units: Prep Date:Sample ID: Client ID: Run No:wt% 11/28/2018 3855621811K89-001AMSD

8612484

Lead 0.009690.05028 250.0484 104 75 125 0.04906 2.45

Qualifiers:

J Estimated value detected below Reporting Limit

BRL Below reporting limit H Holding times for preparation or analysis exceeded

N Analyte not NELAC certified

B Analyte detected in the associated method blank

E Estimated (value above quantitation range)

S Spike Recovery outside limits due to matrix

< Less than Result value> Greater than Result value

R RPD outside limits due to matrix

Rpt Lim Reporting Limit

End of Report