Atch_2_to_Amd_1_Report_0001.pdf
PDF 1 MB Posted
- Attached to
- Replace Shake Roof-TIMU Federal contract opportunity
- Solicitation number
- 140P5424R0004
About this file
This file is an attachment related to an amendment for a federal solicitation to replace shake roofing at Timuquana National Park. The solicitation number is 140P5424R0004 and is being issued by the Department of the Interior National Park Service Southeast Region. Offerors are requested to propose replacing the existing shake roof at Timuquana National Park. The solicitation amendment provides additional details on the scope of work, which involves removing all existing wood shake roofing, underlayment, drip edge and accessories. Offerors should price the project to install new 30-year architectural shingles including underlayment, drip edge and other accessories in accordance with the specifications. Proposals are due by April 15th and the contract is expected to be awarded by May 1st.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P5424R0004_Amd_0003.pdf | ||
| Sol_140P5424R0004_Amd_0002.pdf | ||
| Sol_140P5424R0004_Amd_0001.pdf | ||
| Atch_1_to_Amd_1_QandAs_0001.pdf | ||
| Sol_140P5424R0004.pdf | ||
| Atch_4_Site_Visit_Info.pdf | ||
| Atch_1_SOW.pdf | ||
| Atch_5_Past_Perf_Questionnaire.pdf | ||
| Atch_2_DOL_DBA_WD.pdf | ||
| Atch_3_Drawings_and_Photos.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
November 30, 2018
Dear Order No:
RE:
Analytical Environmental Services, Inc. received samples on for the analyses presented in following report.
No problems were encountered during the analyses. Additionally, all results for the associated
Quality Control samples were within EPA and/or AES established limits. Any discrepancies associated with the analyses contained herein will be noted and submitted in the form of a project Case Narrative.
AES’s accreditations are as follows:
-NELAP/State of Florida Laboratory ID E87582 for analysis of Non-Potable Water, Solid & Chemical
Materials, Air & Emissions Volatile Organics, and Drinking Water Microbiology & Metals, effective
07/01/18-06/30/19.
State of Georgia, Department of Natural Resources ID #800 for analysis of Drinking Water Metals, effective
07/01/18-06/30/19 and Total Coliforms/ E. coli, effective 04/25/17-04/24/20.
-AIHA-LAP, LLC Laboratory ID: 100671 for Industrial Hygiene samples (Organics, Metals, PCM Asbestos, Gravimetric), Environmental Lead (Paint, Soil, Dust Wipes, Air), and Environmental Microbiology (Fungal)
Direct Examination, effective until 11/01/19.
These results relate only to the items tested. This report may only be reproduced in full.
If you have any questions regarding these test results, please feel free to call.
Sincerely, Project Manager
1811M21
Morgan Baird National Park/Timucuan Preserve
11676 Palmetto Ave Jacksonville FL 32226
Main House Painting
Chris Pafford
11/26/2018 4:25:00 PM
Morgan Baird:
Analytical Environmental Services, Inc Date: 30-Nov-18
National Park/Timucuan Preserve TOTAL LEAD IN PAINT (NIOSH 7082)
Matrix:
Lab Order: 1811M21
Paint
Date Received:
Project: Main House Painting
11/26/2018 4:25:00 PM
Client:
Reporting
Limit AnalystUnitsResultClient Sample IDLaboratory ID
Date
Analyzed
Date
Collected DF Qual
1811M21-001A MH#1 NW Corner 2.33 wt% 0.274 29.74 11/19/2018 11/28/2018 AS
1811M21-002A MH#2 South Face East Side 0.0179 wt% 0.00962 1 11/19/2018 11/28/2018 AS
1811M21-003A MH#3 East Window 0.0386 wt% 0.00917 1 11/19/2018 11/28/2018 AS
1811M21-004A KH#1 South Face 1.34 wt% 0.206 21.17 11/19/2018 11/28/2018 AS
1811M21-005A KH#2 West Doorway Overhang 0.588 wt% 0.108 11.12 11/19/2018 11/28/2018 AS
1811M21-006A KH#3 West Window Frame 0.373 wt% 0.00981 1 11/19/2018 11/28/2018 AS
Qualifiers: BRL - Not Detected at the Reporting Limit DF - Dilution Factor
B - Analyte detected in the associated Method Blank
SAMPLE/COOLER RECEIPT CHECKLIST
1. Client Name: AES Work Order Number:
2. Carrier: FedEx UPS USPS Client Courier Other
Yes No N/A Details Comments
3. Shipping container/cooler received in good condition? damaged leaking other
4. Custody seals present on shipping container?
5. Custody seals intact on shipping container?
6. Temperature blanks present?
7.
Cooler temperature(s) within limits of 0 6 C? [See item 13 and 14 for temperature recordings.]
Cooling initiated for recently collected samples / ice present
8. Chain of Custody (COC) present?
9. Chain of Custody signed, dated, and timed when relinquished and received?
10. Sampler name and/or signature on COC?
11. Were all samples received within holding time?
12. TAT marked on the COC? If no TAT indicated, proceeded with standard TAT per Terms & Conditions.
13. Cooler 1 Temperature C Cooler 2 Temperature C Cooler 3 Temperature C Cooler 4 Temperature C
Cooler 5 Temperature C Cooler 6 Temperature C Cooler 7 Temperature C Cooler 8 Temperature C
15. Comments:
I certify that I have completed sections 1 1 (dated initials).
Yes No N/A Details Comments
16. Were sample containers intact upon receipt?
17. Custody seals present on sample containers?
18. Custody seals intact on sample containers?
19. Do sample container labels match the COC?
incomplete info illegible no label other
20. Are analyses requested indicated on the COC?
21. Were all of the samples listed on the COC received?
samples received but not listed on COC samples listed on COC not received
22. Was the sample collection date/time noted?
23. Did we receive sufficient sample volume for indicated analyses?
24. Were samples received in appropriate containers?
25. Were VOA samples received without headspace (< 1/4" bubble)?
26. Were trip blanks submitted? listed on COC not listed on COC
27. Comments:
I certify that I have completed sections 1 27 (dated initials).
Yes No N/A Details Comments
28. Have containers needing chemical preservation been checked? *
29. Containers meet preservation guidelines?
30. Was pH adjusted at Sample Receipt?
I certify that I have completed sections 28 30 (dated initials).
Clear Save as
National Park Service Timucuan Preserve 1811M21
AMBIENT
14.
AB 11/26/18
This section only applies to samples where pH can be checked at Sample Receipt.
AB 11/26/18
* Note: Certain analyses require chemical preservation but must be checked in the laboratory and not upon Sample Receipt such as Coliforms, VOCs and Oil & Grease/TPH.
AB 11/26/18
Checklist 6.9.17 Rev 2 Locked
30-Nov-18Date:Analytical Environmental Services, Inc
Client:
BatchID:Workorder:
Project Name:
ANALYTICAL QC SUMMARY REPORT
Main House Painting
1811M21
National Park/Timucuan Preserve
270645
RPT Limit QualAnalyte Result SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit
SampleType: BatchID: Analysis Date: Seq No:TestCode: 270645MBLK 11/28/2018TOTAL LEAD IN PAINT by NIOSH 7082
Units: Prep Date:Sample ID: Client ID: Run No:wt% 11/28/2018 385562MB-270645
8612480
Lead 0.0100BRL
RPT Limit QualAnalyte Result SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit
SampleType: BatchID: Analysis Date: Seq No:TestCode: 270645LCS 11/28/2018TOTAL LEAD IN PAINT by NIOSH 7082
Units: Prep Date:Sample ID: Client ID: Run No:wt% 11/28/2018 385562LCS-270645
8612509
Lead 0.02000.6574 0.6010 109 80 120
RPT Limit QualAnalyte Result SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit
SampleType: BatchID: Analysis Date: Seq No:TestCode: 270645MS 11/28/2018TOTAL LEAD IN PAINT by NIOSH 7082
Units: Prep Date:Sample ID: Client ID: Run No:wt% 11/28/2018 3855621811K89-001AMS
8612483
Lead 0.009380.04906 0.0469 105 75 125
RPT Limit QualAnalyte Result SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit
SampleType: BatchID: Analysis Date: Seq No:TestCode: 270645MSD 11/28/2018TOTAL LEAD IN PAINT by NIOSH 7082
Units: Prep Date:Sample ID: Client ID: Run No:wt% 11/28/2018 3855621811K89-001AMSD
8612484
Lead 0.009690.05028 250.0484 104 75 125 0.04906 2.45
Qualifiers:
J Estimated value detected below Reporting Limit
BRL Below reporting limit H Holding times for preparation or analysis exceeded
N Analyte not NELAC certified
B Analyte detected in the associated method blank
E Estimated (value above quantitation range)
S Spike Recovery outside limits due to matrix
< Less than Result value> Greater than Result value
R RPD outside limits due to matrix
Rpt Lim Reporting Limit
End of Report