This document provides specifications for a federal contract opportunity to provide wayside exhibit services for the Lockkeepers House, including planning, design, fabrication and installation of fifteen wayside exhibits. The solicitation is being conducted by the Department of the Interior National Park Service National Office under number 140P3023Q0056. The contractor will be required to fabricate fifteen new wayside exhibits to interpret the historic Lockkeepers House. Specifications include materials for aluminum, steel, and galvanized components as well as fabrication details. The contractor must follow provided design guidelines and standards for visual identity signs.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

National Park Service | U.S. Department of the Interior

NPS UniGuide Sign Standards

Visitor Information Sign System VIS and Wayside Hardware Specification Manual

Office of NPS Identity | NPS UniGuide Sign Program

Center for Media Services | Harpers Ferry, WV 25425 www.hfc.nps.gov/uniguide | 304-535-4069

Revision 3 October 5, 2017 gklaus Text Box Annotated Version

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 2Revision 3 October 5, 2017

Disclosure Statement NPS UniGuide Standards

This publication is an administrative document developed for the guidance of employees of the National Park Service, its contractors, cooperating partners, and federal and state government agencies.

The National Park Service assumes no responsibility for the interpretation or application of the standards and information contained in this manual by other than its own employees. The use of trade names, product specifications, identification of firms and corporations in no way constitutes an official endorsement or approval by the United States

Government of any product, process, or service to the exclusion of others that may be suitable.

This sign standards manual includes data that shall not be disclosed outside the government without permission and shall not be duplicated, used, or disclosed wholly, or in part, for any purpose other than as required by the planning, design, or fabrication of signs for the National Park Service.

This information is the sole property of the Government with unlimited rights in the usage thereof and cannot be copyrighted by private parties.

Disclosure Statement NPS UniGuide Standards

Overview

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 3Revision 3 October 5, 2017

Table of Contents

VIS System Overview 4

Section I - TrailSide Series (TS) 17

Section II - Wall Mount Series (WM) 20

Section III - Low Profile / Wayside Series (LP) 26

Section V - Upright Series (UP) 31

Section V - VIS Hardware Accessories 48

Section VI - VIS Fabrication Drawings 55

Section VII - Specifications 178

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 4Revision 3 October 5, 2017

VIS System Overview Introduction 5

VIS System Overview 6

VIS Hardware Assembly Series 7

VIS Hardware Base Material Options 8

VIS Hardware Mounting Options 9

VIS Panels 10

VIS Panel Sizes 11

VIS Hardware Assembly Codes 15

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 5Revision 3 October 5, 2017

Introduction

Overview

It is estimated that approximately 75% of all park signs fall into the Visitor Information (VIS) category. VIS Signs are designed to present information in a consistent, attractive, convenient, and flexible format. Such information may involve pedestrian or bicycle and (low–speed) motorist guidance, regulations, resource protection, instructions and general information, fee information, safety warnings, maps, and interpretation. VIS Signs may also be used to identify parks (or park areas, features, or facilities) when more monumental identification signs are not required.

The flexible system of post and frame hardware components may be configured in a variety of ways to hold modular sign panels and other accessories. VIS hardware is available in a range of durable materials to suit local conditions, all selected for vandal resistance, low maintenance, and long life–cycle performance.

Sign frames are designed to hold graphic panels made from a variety of materials including porcelain enamel, fiberglass embedment, polycarbonate embedment, high pressure laminate, digitally printed adhesive vinyl on aluminum substrates with protective overlaminates, or computer cut retro–reflective sheeting.

Besides supporting sign panels, VIS hardware is designed to accommodate a number of accessories including bulletin cases, brochure holders, and posting displays.

This manual provides details and information on the specification and fabrication of VIS hardware.

Signs are the most frequently used means of communicating with park visitors. The National Park Service UniGuide Sign Standards provide design and fabrication guidelines for a full range of park signs including Park Identity, Motorist Guidance and Visitor Information (VIS).

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 6Revision 3 October 5, 2017

Removable Capture Rail

Graphic Panel

Welded Frame System with Internal Structural Core Panel

Low Profile wayside Base (LP)

Upright Sign Base (UP)

Wall Mount (WM)

VIS System Overview

Overview

The VIS system consists of a welded frame and core panel that can be attached to posts to create

Low Profile wayside bases, Upright Sign Bases, or for Wall Mount displays. The system consists of an aluminum extrusion or a break–formed steel frame with an internal structural core panel. Sign frames are designed to capture the graphic panel on four sides and includes a secure, but removable, capture rail for ease in changing panels.

Accessories that can be attached to upright bases include bulletin cases, brochure holders, and miscellaneous post displays.

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 7Revision 3 October 5, 2017

VIS Hardware Assembly Series

Trail Sign, Low Profile, Upright, Inline and Kiosks

Scale: 1/2" = 1'-0"

Trail Sign, Low Profile, Upright, Inline and Kiosks

Scale: 1/2" = 1'-0"

Trail Sign, Low Profile, Upright, Inline and Kiosks

Scale: 1/2" = 1'-0"

Trail Sign, Low Profile, Upright, Inline and Kiosks

Scale: 1/2" = 1'-0"

Trail Sign, Low Profile, Upright, Inline and Kiosks

Scale: 1/2" = 1'-0"

Trail Sign, Low Profile, Upright, Inline and Kiosks

Scale: 1/2" = 1'-0" Trail Sign, Low Profile, Upright, Inline and Kiosks

Scale: 1/2" = 1'-0"

Trail Sign, Low Profile, Upright, Inline and Kiosks

Scale: 1/2" = 1'-0"

Overview

The chart to the right provides an overview of the base hardware available in the VIS system.

All VIS bases are available in a variety of material options including weathering steel, galvanized steel, and painted aluminum. Painted aluminum bases are available in three paint color finishes.

The material and finish appropriate for a specific base depends primarily on the sign’s purpose and its location. Weathering steel is an excellent choice for low maintenance in many forested and desert sites; galvanized steel is very durable in coastal and other salt–water and corosive environments; and painted aluminum may be a good choice for an urban environment.

Low to the ground, Trailsides are an excellent choice for plant ID markers, site markers, trail guides, and anywhere a small discreet sign is required.

Designed to stand vertically so they attract attention, Upright bases typically provide practical information to visitors rather than site–specific interpretation.

Like the Low Profile base, Upright bases are available in a variety of material finishes and sizes. Bases can be fabricated as a single unit, double or triple inline unit, and tri-sided and four–sided units. The single unit and inline bases can be configured for one or two-sided display. All of the uprights, (in certain preset sizes) are available with or without a roof structure.

Each base is designed to hold panels or other accessories including bulletin cases.

The Low Profile base is the preferred style for NPS interpretive outdoor exhibits. Available in a variety of material finishes and sizes the base’s simple, unadorned form makes it appropriate for any park landscape.

Wall Mount frames are designed to display information on vertical surfaces. Frames are available in a variety of materials and sizes.

TS Series - Trailsides UP Series - Uprights

Upright Base

Upright Tri (Tri-Side)

Upright Inline 2

Upright Quad (Four-Side)

Upright Inline 3

LP Series - Low Profile

WM Series - Wall Mount

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 8Revision 3 October 5, 2017

VIS Hardware Base Material Options

Overview

Weathering steel is an excellent material option for many NPS sites. Over time, with exposure to the elements, the bases turn a golden brown.

The bases are virtually mainternance free and do not require painting once installed.

Weathering steel bases can last well over 15 years.

Bases shipped are not pre weathered. When they arrive the bases are black and begin the weathering process when exposed to the elements.

Aluminum bases are a good all around choice for many NPS sites. Aluminum bases are primed and painted.

The bases are not maintenance free and do require occasional field cleaning and touch up to keep them looking good.

Aluminum bases are available in three standard paint colors.

All bases are painted with a coarse spatter coat finish for added durability.

Galvanized steel is an excellent choice for saltwater and other marine sites. Prior to final fabrication the base legs and frame are hot dipped galvanized which imparts a protective finish to the steel.

The bases are virtually mainternance free, show little if any sign of rust inhibition, and do not require painting once installed.

Galvanized steel bases can last well over 15 years.

When they arrive the bases have a shiny silver finish. Over time the bases patina to a dull grey.

Weathering Steel

Aluminum Standard Aluminum Paint Finish Colors

NPS Dark Brown

Matthews Paint

MP63856 with

Spatter Finish

NPS Medium Grey

Matthews Paint

MP63850 with

Spatter Finish

NPS Brown

Matthews Paint

MP63848 with

Spatter Finish

Galvanized Steel

VIS base hardware is available in three standard material options: weathering steel, galvanized steel, and painted aluminum. For painted aluminum bases there are three standard color choices.

Note: Colors shown are for representation only.

Actual color chips should be matched to the specification for accuracy.

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 9Revision 3 October 5, 2017

VIS Hardware Mounting Options

Overview

The chart to the right provides a basic overview of the hardware installation options available in the VIS system.

Refer to the fabrication details for more information.

Direct embedment is the typical mounting method for all VIS hardware. Post depth is typically 30" to 36" and posts are secured with concrete.

Stabilizer fins are another mounting accessory for direct embedment. Plates are attached to each base leg. The fins allow installation of the base without the use of concrete.

Socket mounting allows the VIS base to be removed. Oversized sleeves are secured in the ground and the base can slide in and out. This is an excellent choice for park areas with huge snowfall or flood conditions.

Wall mounted bases use a modified baseplate that facilitates installation on low walls.

Baseplate mounting allows installation where a deep footer is not practical. The base features a welded baseplate that attaches to imbeded j-bolts or all-thread rods.

Stabilizer bars are a mounting accessory for direct embedment. The bars are welded to each base leg and prevent racking due to loose and shifting soil. This is a good choice for seashore conditions.

The sled base allows the frame and post to be free standing. For security the base can be mounted with threaded rods.

Deck mount hardware uses a baseplate and anchors to install the base on wooden decks and walkways. Deck mounts are typically custom and site specific.

Direct Embedment (DE) Direct Embedment Stabalizer Fins ( SF)

Direct Embedment Socket Mount (SM)Cap Mount (CM) Baseplate Mount (BP)

Direct Embedment Stabalizer Bars (SB)Sled Base (SB) Deck Mount (DM)

Footer Overview

Scale: 1/2" = 1' 0"

Footer Overview

Scale: 1/2" = 1' 0"

Footer Overview

Scale: 1/2" = 1' 0"

Footer Overview

Scale: 1/2" = 1' 0"

Footer Overview

Scale: 1/2" = 1' 0"

Footer Overview

Scale: 1/2" = 1' 0"

3-IO - 10

GL

1-IO - 10 Low Profile Wall Cap Mount Elevationz

Scale: 1/2" = 1'-0"

3-IO - 10 Mounting Detail

Scale: 1/2 Actual Size

2-IO - 10 Baseplate Plan View

Scale: 1/2 Actual Size 3-

1/ 2"

1- 3/

4" 1-

3/ 4"

3/ 8"

7-1/4"

2" 2-1/2" 1-3/4"1"

1/2" Radius

3/8" -16 x 14" Stainless Steel

J-Bolt with Matching Nuts and Washers

Thru Hole Note: Minimum of Two Holes Per Leg

1/4"1/4"

3" eqeq eq

2"

45°

Align

B as ed o n S ig n

S iz e

2-IO -10 Mounting Hole Detail

Scale: 1/2 Actual Size

1-IO - 11 Low Profile Sled Base Side Elevation

Scale: 1/2" = 1' 0"

3-IO - 11 Top Section

Scale: 1/2" = 1' 0"

2-IO - 11

3-IO - 11

GL

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 10Revision 3 October 5, 2017

VIS graphic panels are designed to provide an attractive and consistent way to present a broad range of messages.

This includes park and facility identity, park regulations, safety warnings, information, interpretation, pedestrian guidance, low speed motorist guidance, and other wayfinding information including maps. The modular grids and design standards of VIS signs allows presentation of content in discrete, easily comprehended “eyefuls” which aids in visitor comprehension and retention of information.

Please refer to the Visitor Information System, Panel

Specification Manual for more information.

VIS Panels

Panels may be produced in porcelain enamel, high pressure laminate, fused polycarbonate, fiberglass embedment, digitally printed adhesive vinyl, or computer cut retro–reflective sheeting.

Selection of material is based on life-cycle cost, budget, exposure to wear, and need for retro–reflective legends if viewed from an auto-mobile. Production methods include digital printing, screen printing, and adhesive–backed computer–cut vinyl.

Overview

Hermit Road

Hermit Road

Lookout Studio

Kolb Studio

Maswik Lodge

Backcountry Information Center

Kennels

Hermits Rest Transfer

Village Route Transfer

Bright Angel Trailhead

Center Road

Bright Angel Lodge

Thunderbird Lodge

Bright Angel Lodge

Kachina Lodge

Parking

Trailview Overlook

Maricopa Point

Hopi Point

Mohave Point

The Abyss

Pima Point

Monument Creek Vista Hermits Rest

Hermit Trailhead

Hermits Rest Route

0.5mi / 0.8km

0.3mi / 0.5km

1.1mi. / 1 .8km

E

C

D

Parking

E

0.8mi / 1.3km

1.1mi / 1.8km

R im

T ra il

Rim Trail

Rim Trail 0.

7m i /

.1 km

Powell Point

Orphan Mine

Parking

N

S

EW

Shuttle Routes

Hermits Rest Route

Village Route

Trails

Restricted Access

Hermits Rest Route National Park Service U.S. Department of the InteriorGrand Canyon National Park

Paved Multi-Use Greenway Trail

Paved Pedestiran Greenway Trail

Unpaved Rim Trail

Hermit Trail

Paved Rim Trail

Greenway Tra il

1.7mi / 2.7 km

0.9mi. / 1.4km

0.7mi / 1.1k m

Shuttle Stop

Park Identity and Entrance Signs Park Fee Signs

Informational Signs Warning and Danger Signs

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 11Revision 3 October 5, 2017

6" and 12" Series Panel Sizes

12x6

12x24

12x36

12x48

6x6

6x12

6x18

Overview

A modular system of panels is available to fit all the

VIS hardware bases. Panel dimensions are specified by width(w) x height(h). Panels are specified in nominal dimensions. Fabricated panels are undercut by 1/16" on each side. For example, a 6" x 6" panel is 5 7/8" x 5 7/8". Post size is determined by panel or base size. Refer to the VIS

Post Hardware charts in the fabrication details.

6" Series Panels

VIS Hardware Assembly Series: TS and UP

12" Series Panels

Barstock Post

2x2 Post

VIS Hardware Assembly Series: LP and UP VIS Hardware Assembly: UP

2x3 Post

12x12

12x18

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 12Revision 3 October 5, 2017

24x12

18x24

18x36

18x48

24x18

24x24

24x36

24x48

18" and 24" Series Panel Sizes

Overview

18" Series Panels

24" Series Panels

VIS Hardware Assembly Series: LP and UP

VIS Hardware Assembly Series: LP and UP

VIS Hardware Assembly Series: UP

VIS Hardware Assembly Series: UP

Barstock Post

2x2 Post

2x3 Post

18x18

18x12

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 13Revision 3 October 5, 2017

36x12

36x24

36x18

36" Series Panel Sizes

Overview

36" Series Panels

VIS Hardware Assembly Series: LP and UP

VIS Hardware Assembly Series: UP

36x36

36x48

Barstock Post

2x2 Post

2x3 Post

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 14Revision 3 October 5, 2017

48" Series Panel Sizes

Overview

48" Series Panels

VIS Hardware Assembly Series: LP and UP

48x18

48x24

Barstock Post

2x2 Post

2x3 Post

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 15Revision 3 October 5, 2017

VIS Hardware Assembly Codes

Overview

Although the VIS is a system of simple components, material choices, panel sizes, and mounting options offer a multitude of fabrication options. In order to adequately describe a base and its attributes a code system has been created to aid in specification of base hardware.

The code system provides the information necessary to describe the base, its size, mounting, and other options for fabrication. A sample specification code might look like this:

UP_24x36_WS_DE_PF_BC The code breaks down as follows:

UP

This is the frame type. UP is the specification code for an upright base.

24x36 This is nominal frame size or bulletin case size. In this case a 24 x 36 bulletin case mounts to the base.

WS

This is the material type. This frame will be made from weathering steel.

DE

This is the mounting type. This frame will be a direct embed.

PF

This is the mounting accessory. This frame posts will have post fins for inground stabilization.

BC

This is the base accessory. In this case the base will have a bulletin case instead of a panel.

How to Specify a VIS Base

With the code system it is easy to specify the base type.

For this exercise it is assumed all the decisions about the base have been made including the size, panel content, material mounting, and location.

Use the Code Charts on the page 16 to specify your base.

Step 1. Choose Base Type

From the VIS Hardware Assembly Chart choose the correct assembly code. If necessary refer to the VIS Hardware

Assembly Descriptions on page 7.

Step 2. Choose Nominal Panel Size

If necessary refer to Panel Size Charts, beginning page 11.

Step 3. Choose Base Material

Weathering steel, galvanized steel, or painted aluminum.

Step 4. Choose Mounting Method

Step 5. Choose Mounting Accessory (If Required)

Step 6. Choose Base Accessory

This could be a bulletin case, brochure dispenser, or roof structure for a tri or quad upright.

Step 7. Additional Notes

Here you would indicate additional information for the fabricator including custom requests or modifications and colors.

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 16Revision 3 October 5, 2017

VIS Hardware Assembly Codes Charts

Overview

Trailside Base

Wall Mount

Low Profile Wayside Base

Upright Base

Upright Inline 2 (Double)

Upright Inline 3 (Triple)

Upright Tri-Sided (Kiosk)

Upright Quad-Sided (Kiosk)

Code Descriptions

VIS Hardware Assembly Type

TS

WM

LP

UP

UPN2

UPN3

UPTR

UPQU

Weathering Steel

Galvanized Steel

Painted Aluminum

Code Descriptions

VIS Material Options Chart

WS

GS

AL

Bulletin Case

Brochure Holder

Miscellanous posting

Roof Structure (Upright Only)

Strap Kit

Code Descriptions

VIS Hardware Accessory

BC

BH

MP

RS

SK

Direct Embedment

Base Plate

Socket Mount

Sled Base (Free Standing)

Deck Mount

Wall Mount

Code Descriptions

VIS Hardware Mounting Type

DE

BP

SM

SB

DM

WM

Post Fins (Embed w/o Concrete)

Stabilizer Bars (For Shifting Soils)

Code Descriptions

VIS Hardware Mounting Accessory

PF

SB

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 17Revision 3 October 5, 2017

Section I Trailside Series (TS)

Trailside Series Overview (TS) 18

Trailside Base Sizes 19

6" Series

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 18Revision 3 October 5, 2017

Trailside Series Overview (TS)

Section I: Trail Side Series

Small and simply formed, NPS “trailside” exhibits bases offer an unobtrusive way to provide brief interpretive message or important safety information with minimal impact on the landscape. Trailsides are available in weathering steel, galvanized steel, or painted aluminum and can accommodate several types of graphic panels, attached with stainless steel barrel nuts as shown on page 58. The final assembly is mounted by direct embedment into the ground. The angled tab at the bottom of the base prevents uplift and removal once the base is installed.

Trail Sign, Low Profile, Upright, Inline and Kiosks

Scale: 1/2" = 1'-0"

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 19Revision 3 October 5, 2017

6" Series

Scale: 1/2" = 1'

TS-6x6

TS-6x12 TS-6x18

Section I: Trail Side Series

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 26Revision 3 October 5, 2017

Section III Low Profile Series / Wayside Series (LP)

Low Profile Overview (LP) 27

Low Profile Base Sizes 28

6" Series

12" Series

18" Series

24" Series

36" Series

48" Series

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 27Revision 3 October 5, 2017

Low Profile Series Overview (LP)

Section III: Low Profile Series December 1, 2008

NPS “low–profile” wayside exhibit bases are designed to diminish their presence on the landscape by using the least material required to securely hold an exhibit panel. Panels are positioned at a 45–degree angle to permit visitors a clear view of the feature that the exhibit interprets. Bases are available in three materials, appropriate to a variety of landscapes: weathering steel for forested or desert environments; galvanized steel for coastal zones; and painted aluminum (in three standard colors) for urban areas. The first two materials require little maintenance.

The legs of most wayside bases are directly embedded into the ground, although other mounting methods are available to accommodate site conditions. As illustrated on the following pages, NPS waysides bases come in a wide range of panel sizes which are held within a full-frame assembly.

The top frame member is secured by a replaceable set screw which can be easily removed to allow panel replacement.

Trail Sign, Low Profile, Upright, Inline and Kiosks

Scale: 1/2" = 1'-0"

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 28Revision 3 October 5, 2017Section III: Low Profile Series

GL

12" Series

Scale: 1/2" = 1'

6" Series

Scale: 1/2" = 1'

LP-6x12 Barstock Post

LP-12x6 Barstock Post

LP-12x12 Barstock Post 2x2 Post

LP-12x18 2x2 Post

LP-12x24 2x3 Post

LP-6x12 Barstock Post

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 29Revision 3 October 5, 2017Section III: Low Profile Series

GL

18" Series

Scale: 1/2" = 1'

24" Series

Scale: 1/2" = 1'

LP-18x12 2x2 Post

LP-24x12 2x2 Post 2x3 Post

LP-24x18 2x3 Post

LP-24x24 2x3 Post

LP-18x18 2x2 Post 2x3 Post

LP-18x24 2x3 Post

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 30Revision 3 October 5, 2017Section III: Low Profile Series

GL

36" Series

Scale: 1/2" = 1'

48" Series

Scale: 1/2" = 1'

LP-36x12 2x3 Post

LP-48x18 2x3 Post

LP-48x24 2x3 Post

LP-36x18 2x3 Post

LP-36x24 2x3 Post

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 55Revision 3 October 5, 2017

Section VI VIS Fabrication Detail Drawings

Trailside (TS) 56

Wall Mount (WM) 60

Low Profile (LP) 65

Upright Series (UP) 78

Upright Inline 2 Series (UPN2) 107

Upright Inline 3 Series (UPN3) 114

Upright Tri Sided Series (UPTR) 123

Upright Quad Series (UPQU) 135

Bulletin Case with Posts (BC) 148

Bulletin Case Wall Mount (BC) 151

Brochure Holder (BH) 154

Miscellaneous Posting (MP) 156

Accessory Add-On Panel 158

Installation Options 161

Reference Charts 175 gklaus Cross-Out gklaus Cross-Out gklaus Cross-Out gklaus Cross-Out gklaus Cross-Out gklaus Cross-Out gklaus Cross-Out

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 56Revision 3 October 5, 2017

Trailside (TS)

Section VI: Details

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 57Revision 3 October 5, 2017Section VI: Details

TS - 01

1-TS - 01 Trail Side Front and Side Elevation

Scale: 1/2" = 1' - 0"

6"

5-7/8"

3/ 4"

5/8"5/8" eq eq

Pa n el H ei g h t:

2" o r

3/ 4"

Radius 1/8"

Radius Panel Edge

Optional 1/4" Holes for 4-Corner Panel Attachment

Breakform Bend

1/4" Hole to Accept 3/8" x 1/4" Barrel Diameter 18-8

Stainless Steel Torx Pin In Head Barrel with 1/4", 10-24, 18-8 Stainless Steel, Torx Pin

In Head Machine Screw

Line of Panel

Trailside Base

2-TS - 01 Panel Attachment Detail

Scale: 1/2 Actual Size

45°

2-TS - 01

1-TS - 02

1-TS - 03

GL

Steel and Aluminum Fabrication

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 58Revision 3 October 5, 2017Section VI: Details

TS - 02

1-TS - 02 Trail Side Side Elevation

Scale: Actual Size

3/8" x 1/4" Barrel Diameter 18-8 Stainless Steel Torx Pin In Head Barrel with 1/4", 10-24, 18-8 Stainless Steel, Torx Pin

In Head Machine Screw

.250 Breakformed Steel Base

.125 Graphic Panel

6"

Panel Height: 6", 12" or 18"

1/16"

1/16"

3/4"

3/4"

2-TS - 02 Connection Detail

Scale: 1-1/2" = 1' - 0"

45°

Steel Fabrication

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 59Revision 3 October 5, 2017Section VI: Details

TS - 03

1-TS - 03 Trail Side Side Elevation

Scale: Actual Size

2-TS - 03 Connection Detail

Scale: 1-1/2" = 1"-0"

3/8" x 1/4" Barrel Diameter 18-8 Stainless Steel Torx Pin In Head Barrel with 1/4", 10-24, 18-8 Stainless Steel, Torx Pin

In Head Machine Screw

.250 Breakformed Aluminum Base

.125 Graphic Panel

6"

Panel Height: 6", 12" or 18"

1/16"

1/16"

3/4"

3/4"

45°

Aluminum Fabrication

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 65Revision 3 October 5, 2017

Low Profile (LP)

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 74Revision 3 October 5, 2017Section VI: Details

LP - 09

5/1 6"

3/4"

1-LP - 09 Low Profile Elevation

Scale: 1/2" = 1' -0"

3-LP - 09 Side Section Cut

Scale: 1/2 Actual Size

See Installation Options

1/4" Diameter, 18-8 Stainless Steel High Strength, Wide Grip, Dome Style Blind Rivet Note: Refer to Rivet Chart for Quantity per Frame

1/4"-20 x 3/8" Long, 18-8 Stainless Steel, Countersunk Flat Head, Phillips Machine Screw

Note: Top of Frame is Connected by Screws and is Removable

Post Cap Welded to Top of Post

1/4"-20, 18-8 Stainless Steel Machine Screw

Nut Welded to Steel Angle

3"

Note: Grind Flush

67.5°

67.5°

45°

2-LP - 09 Post Detail

Scale: 3" = 1' -0"

3"2"

1- 3/4

3-LP - 09

2-LP - 09

1-

LP

3/4" .125" Steel Core Panel Welded to Angle

.090 to .125 Graphic Panel

1" x 1" x 1/8" Breakformed Steel Angle

1-3/4" x 3/4" x 1/8" Breakformed Steel Angle

1/8" Drilled Weep Hole Note: See Weep Hole Chart

2" x 3" x 1/8" Tubular Steel Post

3/4"

1" x 1" x 1/8" Breakformed Steel Angle

1-3/4" x 3/4"x 1/8" Breakformed Steel Angle

45°

GL

General Note:

All breakformed steel and aluminum frame edges shall be eased to prevent sharp edges and allow paint adherence.

Steel Fabrication

Low Profile (LP): 2" x 3" Post

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 75Revision 3 October 5, 2017Section VI: Details

LP - 10

1/8" Undercut Panel

1/ 8"

U n d er cu t

Pa n el

5/

3/ 4"

1/

3/4"

1/16"

1- 3/

4"

1-LP - 10 Frame Front Elevation

Scale: 1/2 Actual Size

2-LP - 10 Frame Top Section

Scale: 1/2 Actual Size

2-LP - 10

1/8" Steel Core Panel Welded to Steel Angle

.090 to .125 Graphic Panel

1/16" Gap For Panel Expansion

1" x 1" x 1/8" Breakformed Steel Angle

2" x 3/4" x 1/8" Breakformed Steel Angle

2" x 3" x 1/8"Tubular Steel Posts

See Weld Chart

1" x 1" x 1/8" Breakformed Steel Angle

1/4" Diameter, 18-8 Stainless Steel High Strength, Wide Grip, Dome Style Blind Rivet Note: Refer to Rivet Chart for Quantity per Frame

1/16" Gap for Panel Expansion

2" x 3/4" x 1/8" Breakformed Steel Angle

Line Of 1/8" Steel Frame

Post Cap

Line Of 1/8" Undercut Graphic Panel

2" x 3" x 1/8" Tubular Steel Posts

N o m in al D im en si o n

/2

Steel Fabrication (Continued)

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 76Revision 3 October 5, 2017Section VI: Details

LP - 11

3/8" Diameter, Aluminum Drive Rivets

Note: Refer to Rivet Chart for Quantity per Frame

3/8

1- 3/4

"1/4"-20 x 1/2" Long, 18-8 Stainless Steel, Countersunk Flat Head, Phillips Machine Screw

Note: Top of Frame is Connected by Screws and is Removable

Post Cap Welded to Top of Post

3"

Note: Grind Flush

67.5°

67.5°

45°

See Installation Options

3"2"

1-LP - 11 Low Profile Elevation

Scale: 1/2" = 1' -0"

3-LP - 11 Side Section Cut

Scale: 1/2 Actual Size

2-LP - 11 Post Detail

Scale: 3" = 1' -0"

3-LP - 11

2-LP - 11

1-

LP

3/16" Aluminum Core Panel Welded to “F” Extrusion

.090 to .125 Graphic Panel

NPS Standard 3/16" Aluminum “F” Extrusion

1/8" Drilled Weep Hole Note: See Weep Hole Chart

45°

2" x 3" x 1/8" Tubular Aluminum Post

1" x 1" x 3/16" Breakformed Aluminum Angle

1-3/4" x 3/4" x 3/16" Breakformed Aluminum Angle

3/4"

3/4"

GL

1/4"-20, 6061-T6 Machine Screw Nut

Welded to Aluminum Angle

General Note:

All breakformed steel and aluminum frame edges shall be eased to prevent sharp edges and allow paint adherence.

Aluminum Fabrication

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 77Revision 3 October 5, 2017Section VI: Details

LP - 12

See Weld Chart

1-LP - 12 Frame Front Elevation

Scale: 1/2 Actual Size

2-LP - 12 Frame Top Section

Scale: 1/2 Actual Size

1/8" Undercut Panel

1/ 8"

U n d er cu t

Pa n el

3/ 8"

3/ 4"

1/

3/4"

1/16"

1- 3/

4"

2-LP - 12

Standard NPS 3/16" Aluminum “F” Extrusion

3/8" Diameter, Aluminum Drive Rivets Note: Refer to Rivet Chart for Quantity per Frame

1/16" Gap for Panel Expansion

Line Of 3/16" Aluminum Frame

Post Cap

Line Of 1/8" Undercut Graphic Panel

2" x 3" x 1/8" Tubular Aluminum Posts

3/16" Aluminum Core Panel Welded to Aluminum Angle

.090 to .125 Graphic Panel

1/16" Gap For Panel Expansion

Standard NPS 3/16" Aluminum “F” Extrusion

2" x 3" x 1/8" Tubular Aluminum Posts

N o m in al D im en si o n

/2

Aluminum Fabrication (Continued)

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 161Revision 3 October 5, 2017

Installation Options

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 162Revision 3 October 5, 2017

GL GL

Based on Sign Size

Concrete Footer

Backfill

Gravel Layer (For Drainage)

2x2 or 2x3 Post

3"

12"

M in im u m , 3

6" M ax im u m

6"

1-IO - 01 Direct Embedment

Scale: 1-1/2" = 1'-0"

2-IO - 01 Direct Embedment with Mow Ring

Scale: 1-1/2" = 1'-0"

Direct Embedment (DE)

IO - 01

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 163Revision 3 October 5, 2017

2-IO - 01 Socket Cap Detail

Scale: 3" = 1'-0"

2-IO - 01 Socket Cap Front and Side Elevations

Scale: 3" = 1'-0"

Gravel Layer (For Drainage)

3"

1/4" Stainless Steel Thru Bolt with Washer and Nut

Socket IOunt Sleeve

Backfill

Base Post

12"

M in im u m , 3

6" M ax im u m

6"

Width Based on Sign Size

3" 3"

2- 1/

4"

1- 1/

2" 3/

4" 2- 1/

4"

1- 1/

2" 3/

4"

1/ 4"

1/4"

Sleeve Cap Welded to Post

Bolt Hole

1/4" Stainless Steel Thru Bolt with

Washer and Nut

1-IO - 02 Direct Embedment with Socket Mount

Scale: 1-1/2" = 1'-0"

GL

Direct Embedment with Socket Mount (SM)

IO - 02

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 164Revision 3 October 5, 2017

3/8" Baseplate Welded to Sign Post Note: See Following Pages for Baseplate Dimensions

3/8" -16 x 14" Stainless Steel J-Bolt with Matching Nuts and Washers Note: Four per footing

Concrete Footer

Gravel Base (For Drainage)

Backfill

12" Minimum

Based on Sign Size

1-IO - 03 Baseplate Mount: Landscape, Elevation

Scale: 1-1/2" = 1'-0"

M in im u m , 3

6" M ax im u m

6"

Upright Series Baseplate Mount (BP): Landscape

IO - 03

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 165Revision 3 October 5, 2017

Upright Series Baseplate Mount (BP): Hard Surface

Section VI: Details

IO - 04

GL

3/8" Baseplate Welded to Sign Post Note: See Following Pages for Baseplate Dimensions

Hard Surface

Grout

Compact Base Aggregate

3/8" -16 x 14" Stainless Steel J-Bolt with Matching Nuts and Washers Note: Four per footing

Concrete Footer

Gravel Base (For Drainage)

12" Minimum

Based on Sign Size

1-IO - 04 Baseplate Mount: Hard Surface, Elevation

Scale: 1-1/2" = 1'-0"

M in im u m , 3

6" M ax im u m

6"

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 166Revision 3 October 5, 2017

Baseplates

Section VI: Details

IO - 05

10"

1"

5"

10"

1"

5"

5"

3/4"

2 1/2"

3/ 4"

5"

2- 1/

2"

5"

3/4"

2 1/2"

5"

3/ 4"

2- 1/

2"

Hole to Accept 3/8" -16 x 14"

Stainless Steel J-Bolt

Hole to Accept 3/8" -16 x 14"

Stainless Steel J-Bolt

Hole to Accept 3/8" -16 x 14"

Stainless Steel J-Bolt

1-IO - 05 Baseplate Plan View, 2" x 2" Post Scale: 3" = 1'-0"

2-IO - 05 Baseplate Plan View, 2" x 3" Post Scale: 3" = 1'-0"

3-IO - 05 Baseplate Plan View, 6" x 6" Post Scale: 3" = 1'-0"

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 167Revision 3 October 5, 2017

Baseplates

Section VI: Details

IO - 06

1-IO - 06 Baseplate Plan View, 3" x 5" Post Scale: 3" = 1'-0"

8"

1"

4"

8"

1"

4"

2-IO - 06 Baseplate Plan View, 4" x 4" Scale: 3" = 1'-0"

8"

1"

4"

8"

1"

4"

3-IO - 06 Baseplate Plan View, UP Tri Post Scale: 3" = 1'-0"

8"

1"

4"

8"

1"

4"

Hole to Accept 3/8" -16 x 14" Stainless Steel J-Bolt

Hole to Accept 3/8" -16 x 14" Stainless Steel J-Bolt

Hole to Accept 3/8" -16 x 14" Stainless Steel J-Bolt

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 172Revision 3 October 5, 2017

Thru Hole Note: Minimum of Two Holes Per Leg

1/4"1/4"

3" eqeq eq

2"

45°

Align

B as ed o n S ig n

S iz e

2-IO -10 Mounting Hole Detail

Scale: 1/2 Actual Size

1-IO - 11 Low Profile Sled Base Side Elevation

Scale: 1/2" = 1' 0"

3-IO - 11 Top Section

Scale: 1/2" = 1' 0"

2-IO - 11

3-IO - 11

GL

GL

Low Profile Series Sled Base (SB)

IO - 11

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 175Revision 3 October 5, 2017

Reference Charts

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 176Revision 3 October 5, 2017

VIS Post Size Charts

12 18 24 366 48

NA

NA

2 x 2 2 x 2

BS BS

2 x 3 2 x 3

BS BS BSBS

2 x 3

NA 2 x 2

NA

2 x 2 2 x 3 2 x 3 2 x 3

2 x 3 2 x 3 2 x 3 2 x 3

24 2 x 3

2 x 2 2 x 2 2 x 3 2 x 36 2 x 3

12 18 24 36 48

2 x 2 2 x 2 2 x 2

BS BS

BS

2 x 3 2 x 3 2 x 3

NA

2 x 22 x 2 2 x 2 2 x 3 2 x 3 2 x 3

2 x 3 2 x 3 2 x 3 2 x 3

24 2 x 3

NA 2 x 3 2 x 3 2 x 3 2 x 336 NA

NA 2 x 3 2 x 3 2 x 3 2 x 348 NA

NA 2 x 2 2 x 2 2 x 3 2 x 36 NA

BS BS BS

Low Profile Hardware Post Chart Panel Width

Upright Hardware Post Chart Panel Width

Pa n el H ei g h t

Pa n el H ei g h t

24 x 36 36 x 48 2 x 3 3 x 5

4 x 4

3 x 52 x 3

6 x 6 n2 n3

Quad

Inline and Quad Hardware Post Chart Panel Size

K io sk T yp e

BS

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 177Revision 3 October 5, 2017

VIS Weld and Rivets Charts

Weld Joints Per Frame Chart Panel Width

Pa n el H ei g h t

Rivets Per Frame Chart Panel Width

Pa n el H ei g h t

0 2 2 2 4 4 2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2 2 2 2 2 2 2 2 2

2 2 2 2 2 2 2 2 2 2

3 3 3 3 3 3 3 3

3 3 3 3 3 3 3 3

N/A

N/A

N/A

N/A

N/A

12 18 24 36 48

2 2 2 2 3 3 2 2 2 2 2 2

3 3 3 3 3 3 3 3 3 3 3 3

3 3 3 3 3 3 3 3 3 3

3 3 3 3 3 3 3 3

3 3 3 3 3 3 3 3

N/A

N/A

N/A

N/A

N/A

12 18 24 36 48

Side Side

Top

Bottom

Top Rail Screw Location for Top Rails Chart Rail Length

Weep Hole Location Chart Panel Width

2 2 3 3 3 3 3 3

6 12 18 24 36 48

3 eq eq 3 3 eq eq 3

Numbers are in inches.

L Si d e

C en te r

L

C en te r

R

R S id e

Holes on Rail

2 2 3 3 3 3 3 3

6 12 18 24 36 48

3 eq eq 3 3 eq eq 3

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 178Revision 3 October 5, 2017

Section VII Specifications

General Requirements 179

Materials Overview 182

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 179Revision 3 October 5, 2017

General Requirements

Section VII: Specifications

Frames

The VIS System includes a fabricated panel capture frame with a removable top rail cap and a structural core panel.

The frame is designed to contain and capture the graphic panel on four sides. Frames can be configured for one or two-sided display.

Frames fabricated in aluminum utilize an NPS standard

“F” extrusion welded to a solid sheet aluminum core panel for structural rigidity. The frame features a removable top extrusion secured with tamper proof hardware to allow installation and removal of graphic panels.

Two-sided frames utilize a break-formed channel system with floating internal core panels for structural rigidity.

The top channel is removable and secured with tamper proof hardware.

Frames fabricated from steel (including one and two–sided structures in weathering and galvanized material) utilize a break–formed channel system with floating internal core panels for structural rigidity.

Posts

The VIS system features aluminum and steel tubular posts.

Posts material for upright and low profile bases includes tubular aluminum and carbon steel in 2" x 2", 2" x 3" sizes, and 1/2" x 2" bar stock. Carbon steel can be galvanized for marine environments.

Panels

Sign panels are inserted into the frame in front of the core panel. The sign frames accommodate a variety of graphic panel types including porcelain enamel, fiberglass embedment, polycarbonate embedment, high pressure laminate, digitally printed adhesive vinyl on aluminum with protective overlaminates, or computer cut retro–reflective sheeting on aluminum. The frame system can accommodate panel thicknesses from .090 up to .125.

Signs and sign assemblies shall be manufactured using materials and fabrication processes as described in these specifications and in the companion technical drawings.

The Visitor Information System (VIS) consists of a standard group of post–and–frame components and accessories that are fabricated from aluminum or steel and mechanically assembled. Refer to the VIS Sign Fabrication Drawings for specific details and fabrication guidelines.

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 180Revision 3 October 5, 2017Section VII: Specifications

Dimensions

Inch dimensions are used for legend size and all related dimensions including layout grids, panel sizes, post lengths, mounting height, and post drilling for connection of panel to post. All hardware, machine parts (cast caps, mechanical fasteners, connection details), and materials (tube, dimensional lumber) are specified in inches. Dimension for assemblia and panels are listed by length x width.

Note: Panel dimensions described in this manual are nominal. Nominal sizes are used for ease of specification.

Fabricated panels shall be undercut by 1/16" on each side. For example a specified, nominal 24" x 36" panel, shall be fabricated to a finished size of 23–7/8" x 35–7/8".

Frames shall be fabricated to allow an expansion tolerance of

1/16" on all sides. The outer dimensions of the frame and core panel assembles shall be 1/2" larger than the specified nominal size. For example a nominal 36" x 24" assembly shall be frabricated to an outer dimension of 36 1/2" x 24 1/2".

This leaves 1/8" of expansion on all four sides.

Hardware

The contractor shall provide all hardware, including screws, rivets, wej-it studs, threaded roads and j-bolts as required to fully assemble and install each base or assembly structure.

Material Options and Substitutions

All materials shall be new and of first quality. Materials shall meet or exceed the standards and specifications herein or by reference. All materials and fabrication methodology shall comply with this specification or be an “approved equal”.

A limited number of materials have been specified by manufacturer’s trade name. These products are specified as examples and not to limit use of alternative products and suppliers that are of equal or superior quality.

Function

These specifications are provided as a guideline for the fabrication, assembly, and installation of VIS signs for the

UniGuide Program of the National Park Service. Material and fabrication specifications are provided for each structure.

All signs shall be fabricated to the specifications described in this chapter. Additional instructions and requirements including modifications to structures and details shall be provided within individual contracts that describe the performance of specific sign fabricators and suppliers.

Sign Identification Codes

Signs within the VIS system are identified by a series of reference code numbers that indicate the type of sign, sign panel/frame size, material mounting type, mounting accessory, and accessory. Refer to the Overview section of this manual for a description of the VIS Code System.

Reference Standards

American Society for Testing and Materials standard specification for Aluminum and Aluminum Alloy Sheet and

Plate (ASTM- 6061-T5 extruded shapes with Type 2: Black anodized finish, and 3003-H16, 3003-H14, 2024-T3, 6061-T6, and 5052-H34 aluminum plate).

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 181Revision 3 October 5, 2017Section VII: Specifications

American Society for Testing and Materials standard specification for Stainless Steel tube and structural shapes (ASTM- 316L and 18-8).

American Society for Testing and Materials standards for

Weathering Steel ASTM-588 (A-847 as a tube product).

American Society for Testing and Materials, and American

Institute for Hollow Structural Sections standards (HSS) for ASTM-500; Standard Specification for Cold-Formed

Welded and Seamless Carbon Steel Structural Tubing in

Rounds and Shapes.

American Society for Testing and Materials standard specification D-523 for paint gloss and D-4587 for accelerated weathering cycles for paint.

American Society for Testing and Materials: Standards for threaded steel rod and “J” bolts

Structural Engineering

All structures have been engineered to meet typical conditions for all national parks. Special conditions that are outside these parameters shall be engineered on a site specific basis.

Quality of Materials

All materials shall be new and of first quality. Materials shall meet or exceed the standards and specifications herein or by reference. Factory seconds shall not be accepted. All materials shall comply with this specification or approved equal.

Engineering

The following criteria have been used as the standards governing material specifications, assemblies and footings for all NPS VIS signs unless otherwise specified or engineered.

Wind Pressure : 20 PSF ***

Soil: 1-TSF (2 KSF)-Minimum * **

Frost Depth : 36" Maximum unless otherwise noted

Concrete: 3000 PSI. / 28 days

* For all direct embedment footings, backfill in 6" lifts tamped to 95% compaction.

** Subgrade materials are assumed to be organic free sand/ gravel/silt, or mixture of same, with bearing capacity of

1-TSF (2 KSF) min, subject to inspection.

*** Exceptions include sign placements along the Gulf of

Mexico and in the region of Cape Hattaras, with installa tions engineered site specific to the location.

If these criteria are not adequate for a specific sign location, modifications shall be made to conform to the specified site conditions in order to maintain structural integrity.

Modifications may include, but are not limited to, thicker panels, larger dimension sign posts, additional structural bracing or components, or larger footing configuration and additional steel rebar.

The design of the structural requirements of special one–of–a–kind signs shall conform to the basic assembly specifications for similar sign types. The modified assembly shall fulfill the requirements of local criteria for wind pressure, soil, and frost depth.

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 182Revision 3 October 5, 2017Section VII: Specifications

This section covers material specifications for all components used in the UniGuide Visitor Information System.

Aluminum Aluminum Frame Extrusions

Extruded aluminum (6061-T6 or 6063-T6/T651), NPS standard “F” channel extrusion. Refer to Chapter VI for drawings and additional information.

Extruded aluminum (6061-T6 or 6063-T6/T651), NPS standard angle top frame extrusion. Refer to Chapter VI for drawings and additional information.

Extruded aluminum (6061-T6 or 6063-T6/T651), NPS standard angle bracket extrusion. Refer to Chapter VI for drawings and additional information.

Aluminum Posts

2" x 2" x 1/8" wall tubular aluminum (6063-T6) posts with 1/8”- 3/16” corner radius for upright and lowprofile assemblies.

3" x 2" x 1/8" wall tubular aluminum (6063-T6) posts with

1/8”- 3/16” corner radius for upright and lowprofile bases, and 24" x 36" double and triple inline assemblies.

1/2" x 2" aluminum barstock (6063-T) for upright and low profile assemblies.

4" x 4" x 1/8" wall tubular aluminum (6063-T6) posts for

24" x 36" and 36" x 48" upright quad post assemblies.

3" x 5" x 1/8" wall tubular aluminum (6063-T6) posts with

1/8”- 3/16” corner radius for 36" x 48" double and triple inline assemblies.

6" x 6" x 1/8" wall tubular aluminum (6063-T6) posts with

1/8”- 3/16” corner radius for 36" x 48" upright quad assemblies with roof structure.

1/4" flat sheet aluminum (5052-H32 or 6061-T6/T651) for trailside assemblies.

Aluminum Core Panels

3/16" flat sheet aluminum (5052-H32 or 6061-T6/T651) core panel for upright and low profile bases.

Aluminum Break-formed C-Channel

.125" sheet aluminum (5052-H32 or 6061-T6/T651) for breakforming C–channels and angles for two-sided frame applications and channels for wall mounts.

Aluminum Baseplates

3/8" plate aluminum (5052-H32 or 6061-T6/T651) for machined drilling of baseplates for base mounting with j–bolts.

See drawings in Section VI for base plate details.

Aluminum Hardware

3/8" drive rivets to attach aluminum frame to post legs.

Stabilizer Plates and Fins

6" x 6" x 1/4" sheet aluminum (5052-H32 or 6061-T6/T651) stabilizer plates welded to bottom of posts to mitigate settling of tubular aluminum upright and low profile posts (as specified).

Materials Overview

National Park Service | U.S. Department of the Interior | NPS UniGuide Program Visitor Information Sign System | VIS and Wayside Hardware Specification Manual 183Revision 3 October 5, 2017Section VII: Specifications

1/8" x 10" x 26" 1/4" sheet aluminum (5052-H32 or 6061-T6/

T651) stabilizer fins welded or bolted to posts to stabilize embedment of tubular aluminum uprights and low profile posts (as specified).

Weathering Steel Weathering Steel Posts

2" x 2" x 1/8" wall tubular weathering steel (A-847) for upright and low profile bases.

2" x 3" x 1/8" wall tubular weathering steel (A-847) for upright and low profile bases, and 24” x 36” double and triple inline assemblies.

1/2" x 2" barstock (A-847) for upright and low profile bases.

4" x 4" x 1/8" wall tubular weathering steel (A-847) for

24" x 36" and 36" x 48" upright quad post assemblies.

3" x 5" x 1/8" wall tubular weathering steel (A-847) for

36" x 48" double and triple inline assemblies.

6" x 6" x 1/8" wall tubular weathering steel (A-847) for

36" x 48" upright quad assemblies with roof structure.

1/8" weathering steel…