Attach_4_-_IDC_FLOOR_PLAN_0001.pdf
PDF 983 KB Posted
- Attached to
- 7J--HAFC IDS MOTION SENSORS Federal contract opportunity
- Solicitation number
- 140P2125Q0124
About this file
These are architectural floor plans for the Harpers Ferry National Historic Site's Interpretive Design Center (IDC), showing detailed layouts for three levels of a building. The ground level floor plan (01A101) covers approximately 16,300 square feet and includes various spaces such as offices, meeting rooms, restrooms, storage rooms, electrical closets, IT server rooms, and corridors. The second level floor plan (01A102) spans roughly 6,840 square feet and features offices, a studio, kitchen, break rooms, conference rooms, and an outdoor deck. The third level floor plan (01A103) encompasses approximately 10,500 square feet with multiple meeting rooms (Vignelli, Everhart, Carson, River View), offices, cubicle areas, electrical rooms, and restrooms. The plans are marked as "FOUO- LAW ENFORCEMENT SENSITIVE" and were created on 04/18/2023 using laser scanning data collected in January 2023 by Langan Engineering.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P2125Q0124_Amd_0002.pdf | ||
| Q_A_p2_0002.pdf | ||
| Attach_6_-_BIRD_BRADY_FLOOR_PLAN_0001.pdf | ||
| Q_A_0001.pdf | ||
| Sol_140P2125Q0124_Amd_0001.pdf | ||
| Attach_5_-_LEWIS_ANTHONY_FLOOR_PLAN_0001.pdf | ||
| Attach_3_-_Vendor_cost_sheet.pdf | ||
| Sol_140P2125Q0124.pdf | ||
| Attach_2_-_Site_Visit_info_HFC_Motion_Sensors.pdf | ||
| Attach_1_-_current_Equipment.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
01A2003
WOMEN RESTROOM
UTILITY CLOSET
MEN RESTROOM
AV THEATER
OFFICES
STORAGE ROOM
REPAIR WORKSHOP
OFFICE
LOUDOUN HEIGHTS
MEETING RM
SHENANDOAH MEETING
ROOM
CORRIDOR
STORAGE RM.
ADMIN. OFFICE
STORAGE
PROJECTION RM.
SOUTH CLIFF
CONFERENCE ROOM
VESTIBULE
A-3
STORAGE ROOM
STORAGE ROOM
STORAGE RM
STORAGE RM.
ELEVATOR
OFFICES
A-6
RECORDING
EQUIPMENT OFFICE
PHOTOCOPY ROOM
STORAGE
OFFICE
ELEC. RM
OFFICE
STORAGE RM
STORAGE RM
IT SERVERS
TEL. CLOSET
A-13
CLOSET
STORAGE
ELECT. CLOSET
MEETING ROOM
STAIR
A-7
LOADING
A-8
STAIRS
01A200
01A200
01A200 5
DN
UP
U P
CUBICLES
ELEC. CLST
01A300
01A300
01A300
01A300
01A300
01A300
01A300
01A300
01A301
01A301
01A301
01A301
01A301
01A301
223' - 5 1/4"
C104C102
C103
C113
C107
C108
C109
C110
C111
C112
C125
C114
C115
C116
C118
C120
C123
C117 C126
C119 C128
C121 C130
C122
C124
C127 C135
C133
C137
C139C131
C129
C134
C132
C136
C138
C141
C140
C143
C145
C142
C144
C146
C147
RETAINING
WALL
+/- 16,300 SF.
WATER FOUNTAIN
LINCOLN
MEETING
ROOM
ELECTRICAL
CLOSET
A B C D E F G H I J K L M N O
117 116 115 114 113 112
01A301
HVAC UNIT
HVAC UNIT
HVAC
UNIT
111112
113114
147 148 149
141110
SCALE IN FEET
4°
B L D
G
FOUO- LAW ENFORCEMENT SENSITIVE
FOUO- LAW ENFORCEMENT SENSITIVE
04/18/2023 OF
HARPERS FERRY
NATIONAL HISTORIC SITE
000000
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
XX
C:\EYP_Temp\Revit_2022\2023-0504_170756601-V-HARPERSFERRY-V22-DETACHED-230802-HP_harinipatel.rvt
IDC GROUND LEVEL
FLOOR PLAN
01A101
1/8" = 1'-0"01A101
1 IDC GROUND LEVEL FLOOR PLAN
NOTE:
1. BUILDING EXTRACTION IS BASED UPON EXISTING
PHYSICAL CONDITION FOUND AT THE SUBJECT SITE.
2. ANY ELEVATIONS SHOWN ARE REFERENCED TO
THE NATIONAL GEODETIC VERTICAL DATUM OF 1988
(NGVD88).
3. INFORMATION SHOWN HEREON HAS BEEN
OBTAINED FROM LASER SCANNING DATA BY LANGAN
ENGINEERING DURING JANUARY OF 2023.
01A200
01A200
01A200 5
U P
UP
D N
DN
STUDIO
KITCHEN
E L
E C
T R
IC
A
L R
M
DIRECTORS CONF
ROOM
ELEVATOR SHAFT
WOMEN RESTROOM
MEN RESTROOM
STORAGE
BREAK ROOM
STAIRS
ENTRANCE
PIN OAK MEETING
ROOM
OFFICE
OFFICE
OFFICE
BREAK ROOM
S U
P P
L
IE
S C
L
OFFICE
OFFICE
OFFICE
U P
OUTDOOR DECK
LINE OF ROOF ABOVE
COVERED DECK
COVERED DECK
01A300
01A300
01A300
01A300
01A300
01A300
01A300
01A300
01A301
01A301
01A301
01A301
01A301
01A301
12' - 4"49' - 10 1/4"138' - 5 1/2"
/4
C200
2006 2007 2008
+/-6,840 SF
WATER FOUNTAINS
PAVERS
PAVERS
5 5
A B C D E F G H I J K L M N O
206205204203
208209
211212
01A301
212213214
225 226
210 211
4°
B L D
G
SCALE IN FEET
FOUO- LAW ENFORCEMENT SENSITIVE
FOUO- LAW ENFORCEMENT SENSITIVE
04/18/2023 OF
HARPERS FERRY
NATIONAL HISTORIC SITE
000000
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
XX
C:\EYP_Temp\Revit_2022\2023-0504_170756601-V-HARPERSFERRY-V22-DETACHED-230802-HP_harinipatel.rvt
IDC SECOND LEVEL
FLOOR PLAN
01A102
1/8" = 1'-0"01A102
1 IDC SECOND LEVEL FLOOR PLAN
01A200
01A200
01A200 5
D N
DN
WOMEN RESTROOM
VIGNELLI MEETING
ROOM
STORAGE
PLOTTER AND
DRAWING STORAGE
ROOM
EVERHART MEETING
ROOM
OFFICES
ELECT. RM
COLOR ROOM
ELECTRICAL - IT RM
CARSON MEETING
ROOM
MEN RESTROOM
RIVER VIEW CONF.
ROOM
KITCHEN
ELEVATOR
STAIR WELL
CUBICLES(TYP.)
01A300
01A300
01A300
01A300
01A300
01A300
01A300
01A300
01A301
01A301
01A301
01A301
200' - 7 3/4"
3009C333C334C335C336C337
C322
C323
C324
C325
C326
C327
C331
C332
C330
C329
C328
C300
C301
C302
C312
C313
C314
C311 C310 C309 C320 C321
C308
C307
C306
C305C303 C304 C315 C316 C317 C318 C319
+/-10,500 SF
WATER
FOUNTAIN
B C D E F G H I J K L M N O
302 303 304 305 306 307 308 309 310 311
313 314 315 316
332 331 330 329 328333334335336337338
01A301
303301
4°
B L D
G
SCALE IN FEET
FOUO- LAW ENFORCEMENT SENSITIVE
FOUO- LAW ENFORCEMENT SENSITIVE
04/18/2023 OF
HARPERS FERRY
NATIONAL HISTORIC SITE
000000
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
XX
C:\EYP_Temp\Revit_2022\2023-0504_170756601-V-HARPERSFERRY-V22-DETACHED-230802-HP_harinipatel.rvt
IDC THIRD LEVEL
FLOOR PLAN
01A103
1/8" = 1'-0"01A103
1 IDC THIRD LEVEL FLOOR PLAN
| Sheets |
| 01A101 - IDC GROUND LEVEL FLOOR PLAN |
| 01A102 - IDC SECOND LEVEL FLOOR PLAN |
| 01A103 - IDC THIRD LEVEL FLOOR PLAN |
| 01A200 - IDC EXTERIOR ELEVATIONS |
| 04A400 - DOOR & WINDOW SCHEDULES |
| 01A102 - IDC SECOND LEVEL FLOOR PLAN.pdf |
| Sheets |
| 01A101 - IDC GROUND LEVEL FLOOR PLAN |
| 01A102 - IDC SECOND LEVEL FLOOR PLAN |
| 01A103 - IDC THIRD LEVEL FLOOR PLAN |
| 01A200 - IDC EXTERIOR ELEVATIONS |
| 04A400 - DOOR & WINDOW SCHEDULES |
| 01A103 - IDC THIRD LEVEL FLOOR PLAN.pdf |
| Sheets |
| 01A101 - IDC GROUND LEVEL FLOOR PLAN |
| 01A102 - IDC SECOND LEVEL FLOOR PLAN |
| 01A103 - IDC THIRD LEVEL FLOOR PLAN |
| 01A200 - IDC EXTERIOR ELEVATIONS |
| 04A400 - DOOR & WINDOW SCHEDULES |
File details come from the government source that posted it. Updated .