B09_32_Standard_Detail_2213-140_0005.pdf
PDF 105 KB Posted
- Attached to
- YOSE 215363 - Replace Tuolumne Meadows WWTP
- Solicitation number
- 140P2026R0001
About this file
This technical drawing is a detailed schematic for a Floor Cleanout design for the United States Department of Interior's Tuolumne Meadows Wastewater Treatment Plant (WWTP) located in Yosemite National Park, California. The drawing provides a cross-sectional view of a piping system component with specific technical details including a membrane, 4-band coupling, sanitary wye, 1/8" bend, and floor cleanout. The note indicates that for cleanout located at the end of a run, the wye and 1/8" bend should be replaced with a short sweep elbow. The drawing is not to scale (NTS) and is prepared by Jacobs engineering firm, with a document number of 2213-140.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .