This document contains a hazardous materials assessment report for the Sandy Hook Lifesaving Station building located at Gateway National Recreation Area in New Jersey. The report identifies asbestos containing materials, lead based paint, and other hazardous materials and wastes present in the building including fluorescent light ballasts and bulbs, electrical equipment, and chemicals. Approximately 60 square feet of asbestos floor tile and 25 square feet of asbestos mastic were identified. Lead based paint was found on wooden walls, ceilings, doors, windows, and plaster throughout the building. Removal and disposal of all hazardous materials will be required prior to planned renovation work. Real-time moisture readings indicated building materials were sufficiently dry with no visible mold observed.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HAZMAT ASSESMENT REPORT
for
Sandy Hook Lifesaving Station
Gateway National Recreational Area
Highlands, Monmouth County, NJ
Prepared For:
Mills + Schnoering Architects, LLC
200 Forrestal Road, Suite 3A
Princeton, NJ 08540
Prepared By:
Langan Engineering and Environmental Services, Inc.
River Drive Center 1, 619 River Drive
Elmwood Park, New Jersey 07407-1338 NJ Certificate of Authorization No: 24GA27996400
Vijay Patel
Senior Associate
April 20, 2015 270039401
Hazmat Assessment Report April 20, 2015
Gateway National Recreational Area
Highlands, Monmouth County, NJ
Langan Project No. 270039401
TABLE OF CONTENTS
Page No.
ACRONYMS ............................................................................................................................... i
EXECUTIVE SUMMARY ........................................................................................................... ii
1.0 INTRODUCTION
2.0 SITE DESCRIPTION
3.0 ASSESSMENT METHODOLOGY
4.0 ASBESTOS CONTAINING MATERIALS
4.1 Terminology
4.2 Observations and Findings
5.0 LEAD-BASED PAINT
6.0 MISCELLANEOUS AND UNIVERSAL WASTE
7.0 MOLD AND MOISTURE ASSESSMENT
8.0 CONCLUSIONS AND RECOMMENDATION
8.1 Asbestos Containing Materials
8.2 Lead Based Paint
8.3 Miscellaneous and Universal Wastes
8.4 Mold and Moisture Assessment
9.0 LIMITATIONS, EXCEPTIONS AND ASSUMPTIONS
TABLES
Table 1 Summary of Asbestos Survey Findings
Table 2 XRF Screening Results
Table 3 Universal/Hazmat Waste Article Inventory
Table 4 Asbestos Abatement Estimates
DRAWINGS
ASL-1 Asbestos Sampling Locations – Basement & 1st Floor
ASL-2 Asbestos Sampling Locations – 2nd Floor
ASL-3 Asbestos Sampling Locations – 3rd Floor
APPENDICES
Appendix A Laboratory Test Results and Chain of Custody Documentations
(Asbestos)
Appendix B Langan’s Certifications and Laboratory Accreditations
Sandy Hook Lifesaving Station Page i
Gateway National Recreational Area
Langan Project No. 270039401
ACRONYMS
USEPA United States Environmental Protection Agency
AHERA Asbestos Hazard Emergency Response Act
OSHA Occupational Safety and Health Administration
CAA Clean Air Act
CFR Code of Federal Regulation
EPA United States Environmental Protection Agency
HEPA High Efficiency Particulate Air
HUD Housing and Urban Development
NESHAPS National Standards for Hazardous Air Pollutants
NJAC New Jersey Administrative Code
NJDEP New Jersey Department of Environmental Protection
NJDOL New Jersey Department of Labor and Industry
NJDHSS New Jersey Department of Health and Senior Services
RCRA Resource Conservation and Recovery Act
PLM Polarized Light Microscopy
TEM Transmission Electron Microscopy
ACM Asbestos-Containing Materials
LBP Lead-Based Paint
PCB Polychlorinated Biphenyls (PCB)
SF Square Feet
LF Linear Feet mg/cm2 Milligrams per square centimeter
XRF X-ray Fluorescence
AAS Atomic Absorption Spectrometry
TCLP Toxicity Characteristic Leaching Procedure
Sandy Hook Lifesaving Station Page ii
Gateway National Recreational Area
Highlands, Monmouth County, NJ
Langan Project No. 270039401
EXECUTIVE SUMMARY
Langan Engineering and Environmental Services, Inc. has prepared this hazardous materials
(Hazmat) assessment report to identify the presence/absence of Asbestos Containing Materials
(ACM), Lead-Based Paint (LBP); Polychlorinated Biphenyls (PCB)/Mercury containing articles and other miscellaneous/universal hazmat materials; and mold/moisture assessment at the
Sandy Hook Lifesaving Station building located at Gateway National Rec Area, Highlands, Monmouth County, New Jersey.
PROJECT INFORMATION:
Client Name:
Mills + Schnoering
Architects, LLC Survey Dates: February 18, 2015
Langan project #: 270039401 Construction Dates: Unknown
Professional’s Project
Manager:
Demian Wincele
Vijay Patel
No. Building: 1
No. of Stories: Three
Email:
dwincele@Langan.com vpatel@langan.com Building Footprint: Unknown
Property Address:
Gateway National Rec.
Area Basement: Partial
Property Town, County, State:
Highlands, Monmouth, New Jersey Property Use: Vacant
The following summarizes Hazmat findings for the building spaces inspected:
Asbestos-Containing Materials (ACM)
CONFIRMED AND ASSUMED ACM
ESTIMATED QUANTITIES
12-inch square thin olive green floor tile/ No glue 10 SF
9-inch square spackled gray floor tile 25 SF
Mastic around chimney (Assumed ACM) 25 SF
Lead Based Paint (LBP)
Based on the XRF screening results and a comparison of the readings to the HUD guidelines, the following building components were identified painted with LBP:
Sandy Hook Lifesaving Station Page iii
Gateway National Recreational Area
Wooden Wall/Ceiling, Window and Door Components – Throughout
Plaster Walls – Throughout
Metal Radiator – Select Locations
Overall, the paint on building components was in fair to good condition. Refer to Table 2 for the
LBP screening data.
Miscellaneous Wastes
The following is an inventory of universal and hazardous waste articles identified in the building.
Article/Device Approx. Quantity
UNIVERSAL WASTE GROUP
Fluorescent lamps 22 Units
MCE Thermostats 1 Units
WASTE CONTAINING RADIOACTIVE MATERIALS GROUP
Smoke detectors 2 Units
PCBs CONTAINING WASTE GROUP
Fluorescent Light Ballasts 16 Units
Electronic equipment containing circuit boards with capacitors such as
Computers and Peripherals, Telephones, TVs, etc.
12 Units
Electrical motors containing capacitors (associated with pumps, fans, shutter door openers, etc.)
3 Units
WASTE CONTAINING CFCs and/or HCFCs GROUP
Exterior mounted A/C, HVAC, Air handling, cooling units 2 Units
Refrigerator/Ice Machine/Water Cooler/Water Fountain/Vending Machine 2 Units
MIXED HAZARDOUS WASTE GROUP
Fire extinguishers 3 Units
Chemicals (Bottles/Cans) 2 Units
BIO HAZARD
Needle Waste Container 1 Unit
* - Due to live electricity and building's operations, electrical devices are assumed to contain
PCBs; EXIT signs and smoke detectors are assumed to contain radioactive materials; and heat transformer systems are assumed to contain CFCs and/or HCFCs.
MCE - Mercury-Containing Equipment; HID - High Intensity Discharge; MVC - Mercury Vapor
Containing; HPS - High Pressure Sodium; MH - Metal Halide; CFCs - Chlorodifluoromethanes (R-
12); HCFCs - Hydrofluorocarbons (R-22)
Sandy Hook Lifesaving Station Page iv
Gateway National Recreational Area
Highlands, Monmouth County, NJ
Langan Project No. 270039401
The aforementioned universal and hazardous materials which will require removal shall be properly recycled, and/or disposed of at a disposal facility permitted to accept such waste. The removal, handling, recycling, and disposal must be performed in accordance with applicable
Federal, State, and local regulations.
Summary of Moisture and Mold Assessment
The building was inspected and evaluated for historical and existing sources of water intrusion, presence/absence of visually apparent microbial growth and sources of characteristic microbial odors. No visible signs of apparent microbial growth or microbial odors were noted during our site visit. On the 1st floor, from the floor up to 4 feet of dry walls were observed removed as part of prior remediation activities.
Sandy Hook Lifesaving Station Page 1
Gateway National Recreational Area
Highlands, Monmouth County, NJ
Langan Project No. 270039401
1.0 INTRODUCTION
Langan Engineering and Environmental Services, Inc. has prepared this hazardous materials (Hazmat) assessment report to identify the presence/absence of Asbestos
Containing Materials (ACM), Lead-Based Paint (LBP); Polychlorinated Biphenyls
(PCB)/Mercury containing articles and other miscellaneous/universal hazmat materials;
and mold/moisture assessment at the Sandy Hook Lifesaving Station building located at
Gateway National Rec Area, Highlands, Monmouth County, New Jersey. We understand that the building was previously impacted by Hurricane Sandy and will be renovated as part of site restoration activities.
The purpose of the survey was to prepare an inventory of the hazmat materials so they could be appropriately segregated, removed and disposed prior to renovations. The remainder of this Report presents our observations, findings, laboratory test results of samples collected, and itemized inventory of hazmat identified in the building.
2.0 SITE DESCRIPTION
The property is situated on a beachfront in Highlands, Monmouth County, New Jersey.
The site is improved with an approximate 2,400 square feet three-story with a partial basement masonry/wood structure built in 1894. The building is listed on the National
Register of Historic Places. It is also part of the Sandy Hook Proving Ground Historic
District.
3.0 ASSESSMENT METHODOLOGY
Asbestos-Containing Materials
The asbestos survey was conducted in accordance with EPA protocol outlined in the
EPA publication “Asbestos in Buildings”. Suspect ACM was visually identified during a room-by-room, floor-by-floor survey of the buildings. Suspect ACM was categorized into various homogeneous materials and types, and sampled and analyzed for asbestos content. Sampling and analysis was conducted in accordance with EPA protocol
600/M4-82-020 per 40 CFR 763. Samples collected were properly packaged in individual containers, sealed; catalogued and chain-of-custody documentation was
Sandy Hook Lifesaving Station Page 2
Gateway National Recreational Area
Highlands, Monmouth County, NJ
Langan Project No. 270039401 completed. Quantities of suspect materials were recorded and observations such as physical condition and friability of the materials were also noted.
Lead-Based Paint Screening Survey
A Niton XL300 X-Ray Fluorescence (XRF) Spectrum Analyzer was used to survey the subject building for the presence of lead-based paint (LBP). The Niton analyzer uses a cadmium 109 radioactive source and an advanced solid-state radiation detector to generate an x-ray fluorescence spectrum of a painted surface. During the analysis, the intensity of the x-rays is converted by the instrument’s internal software into an estimate of the concentration of lead in the substance being analyzed. The results are interpreted as concentrations of lead in milligrams per square centimeter. This device is a field-screening tool, used to collect multiple readings in a short period of time. The method of measurement is based on spectrometric analysis of lead x-ray fluorescence within a controlled depth of interrogation. The reading is an estimate of lead content in all layers of paint. The results are displayed in milligrams per square centimeter
(mg/cm2).
The definition of lead based paint as per the Housing and Urban Development (HUD) guidelines was used to compare and evaluate painted surfaces. According to HUD, an
XRF reading below 1.0 mg/cm2 would designate paint as non-LBP, while a reading of
1.0 mg/cm2 or greater would designate paint as LBP.
Mold and Moisture Assessment
The building was inspected and evaluated for historical and existing sources of water intrusion, presence/absence of visually apparent microbial growth and sources of characteristic microbial odors.
Moisture measurements were collected during the site assessment from various building components. A Delmhorst BD-2100 moisture meter was used to collect moisture readings from drywall, wood wall panel, and wooden joist. Measurements were compared against the manufacturer’s guidelines for assessing moisture content in building materials.
Sandy Hook Lifesaving Station Page 3
Gateway National Recreational Area
Highlands, Monmouth County, NJ
Langan Project No. 270039401
4.0 ASBESTOS CONTAINING MATERIALS
4.1 Terminology
Suspect Asbestos-Containing Materials
Asbestos was used in certain types of construction and building materials. Until a material is examined using light microscopy or a similar technique, the building material is considered as a suspect asbestos-containing material. A few examples of these materials include floor tiles, ceiling panels, thermal system insulation, fireproofing insulation, roofing materials, etc. Any suspect ACM of unknown asbestos content (that is not tested) should be handled as if it were an asbestos containing material.
Asbestos–Containing Material
A material with an asbestos concentration greater than one percent by weight is considered to be asbestos-containing by the United States Environmental
Protection Agency (USEPA). Thus, a material which contains asbestos in concentrations greater than 1% by weight is considered as “positive” while materials that do not contain asbestos or asbestos is detected in concentrations less than one percent by weight are considered as “negative”.
Friable Asbestos–Containing Material
A friable material is one that can be easily crumbled, pulverized, or reduced to powder by hand or mechanical pressure. This characteristic of a building material is directly linked to the potential of the material to release asbestos fibers into the air.
Non-friable Asbestos–Containing Material
Materials that are organically bound normally fall into this category as long as they are in good condition. Some of the materials, which would be defined as non-friable material, include floor tiles, roofing materials, mastic, etc.
4.2 Observations and Findings
The field survey of the subject building was conducted on February 18, 2015 by
Langan’s Sanjay Patel and Fernando Velasquez, USEPA accredited asbestos
Sandy Hook Lifesaving Station Page 4
Gateway National Recreational Area
Highlands, Monmouth County, NJ
Langan Project No. 270039401 inspectors. During the survey, suspect materials observed in the building were documented, assessed, quantified, and sampled as necessary. Suspect materials visually observed in the building included the following:
SUSPECT ACM
RESULTS:
ACM OR NON-ACM
12-inch square thin olive green floor tile/ No glue ACM
9-inch square spackled gray floor tile ACM
Mastic around chimney Assumed ACM
Glue associated with 9-inch square spackled gray floor tiles Non-ACM
Wall plaster (2 - Layers) Non-ACM
Chimney wall plaster Non-ACM
Wall plaster in the basement Non-ACM
Brick mortar Non-ACM
Gypsum board Non-ACM
Ceramic tile grout Non-ACM
Flue patch cement Non-ACM
Stall insulation Non-ACM
Boiler rib gasket Non-ACM
Dark black brown baseboard Non-ACM
Glue associated with baseboard Non-ACM
Stair steps covering/ No glue Non-ACM
Felt paper under wooden siding Non-ACM
Ceramic tile glue Non-ACM
Window glazing Non-ACM
Black coating on wall under 1st layer of gypsum board Non-ACM
Old electrical wire wrap insulation Non-ACM
Forty six (46) samples of the above referenced suspect materials were collected and analyzed using polarized light microscopy (PLM) analytical methodology in accordance with 40 CFR 763 and NESHAP regulations. Non-friable organically bound materials which tested negative using PLM were re-analyzed using transmission electron microscopy (TEM). Samples were analyzed by AmeriSci
New York (AmeriSci), New York, NY.
Sandy Hook Lifesaving Station Page 5
Gateway National Recreational Area
Highlands, Monmouth County, NJ
Langan Project No. 270039401
Asbestos content greater than one percent by weight was detected in two of these forty six samples analyzed. Refer to Table 1 for the summary of asbestos survey findings. Sampling locations are depicted on Drawings ASL-1 thru ASL-3.
The copy of laboratory test results and chain of custody documentation are provided in Appendix A.
5.0 LEAD-BASED PAINT
The LBP survey was also conducted on February 18, 2015 by Sanjay Patel, a USEPA-accredited and State of New Jersey certified Lead Inspector/Risk Assessor. The building areas that were screened primarily consisted of painted walls, floors, stair components, beams, columns, and windows and door components.
A total of fifty-five (55) painted locations were screened for lead. Based on the XRF screening results and a comparison of the data to the HUD guidelines, the paint on majority of the plaster walls and wooden wall, ceiling, beam, column, stair, door and window components in the building was identified as LBP. Overall, the paint on the building components was in good to fair condition. A summary of XRF screening data is provided in Table 2.
6.0 MISCELLANEOUS AND UNIVERSAL WASTE
As mandated by Subtitle C of the Resource Conservation and Recovery Act (RCRA), EPA promulgated hazardous waste regulations in 1980 to ensure that wastes which pose a threat to human health and the environment would be managed safely. In order to be regulated as a hazardous waste under RCRA, a material must first be classified as a solid waste.
Hazardous waste is a waste with properties that make it dangerous or potentially harmful to human health or the environment. Hazardous waste are divided into listed wastes, characteristic wastes, universal wastes, and mixed wastes.
During the survey, a physical inventory of articles which could potentially become hazardous waste was performed which included building’s electrical/electronic system components and heat transformer equipment (i.e. light fixtures, EXIT signs, smoke detectors, A/C and HVAC units, etc.). For the purpose of this report, the ballasts associated with the light fixtures are assumed to contain PCBs; smoke detectors are http://www.epa.gov/osw/hazard/wastetypes/listed.htm http://www.epa.gov/osw/hazard/wastetypes/characteristic.htm http://www.epa.gov/osw/hazard/wastetypes/universal/index.htm
Sandy Hook Lifesaving Station Page 6
Gateway National Recreational Area
Highlands, Monmouth County, NJ
Langan Project No. 270039401 assumed to contain radioactive materials; heat transformer systems are assumed to contain Chlorodifluoromethanes (CFCs) or Hydrofluorocarbons (HCFCs); glass tubes are assumed to contain mercury vapors. An inventory summary of hazardous wastes and other miscellaneous materials/articles that may become hazardous waste is provided in
Table 3.
7.0 MOLD AND MOISTURE ASSESSMENT
The perimeter walls were covered with wooden shingle. The inner face of the perimeter walls were covered with gypsum boards. The interior partitions consisted of plaster walls partially covered with wooden wall panels, and wood frame covered with gypsum boards. The building was observed to have single layer of hardwood flooring.
Previously water impacted gypsum board/plaster (approximately 1 to 4 feet above ground) on the 1st floor was observed removed. A coating of white disinfection or encapsulant was observed on the floor and lower walls.
No visible signs of apparent microbial growth or microbial odors were noted during our site visit. Moisture measurements were collected from drywall and wooden components. Measurements were compared against the manufacturer’s guidelines for assessing moisture content in building materials.
The following is a summary of the measurements collected during the assessment:
Location Moisture Content Reading (%) Determination
Lower wooden walls Readings ranged between >0% to 10.8% Sufficiently dry
Plaster walls Readings ranged between >0% to 1.8% Sufficiently dry
Dry walls Readings ranged between >0.0% to 1.6% Sufficiently dry
Wooden window and door components Readings ranged between >7.2% to 10.4% Sufficiently dry
Wooden floor Readings ranged between >8% to 11.3% Sufficiently dry
Wooden stair components Readings ranged from >7.2% to 10.3% Sufficiently dry
Wooden beams/ columns Readings ranged from >0% to 13.2% Sufficiently dry
Sandy Hook Lifesaving Station Page 7
Gateway National Recreational Area
Highlands, Monmouth County, NJ
Langan Project No. 270039401
8.0 CONCLUSIONS AND RECOMMENDATION
8.1 Asbestos Containing Materials
Regulatory Guidelines and Requirements
Federal
In accordance with the Clean Air Act (CAA), the U.S. Environmental Protection
Agency (EPA) established National Emission Standards for hazardous Air
Pollutants (NESHAP) to protect the public from exposure to airborne pollutants.
Asbestos was one of the air pollutants, which was addressed under the
NESHAP 40 CFR Part 61. The purpose of asbestos NESHAP regulations is to protect the public health by minimizing the release of asbestos when facilities, which contain ACM, are being renovated or demolished. EPA is responsible for enforcing regulations related to asbestos during renovations and demolition, however, the CAA allows the EPA to delegate this authority to State and Local
Agencies. Even after EPA delegates responsibility to a state or Local agency, EPA retains the authority to oversee agency performance and to enforce
NESHAP regulations as appropriate.
State
Asbestos in New Jersey is regulated by Chapter 60 and 120, “Asbestos
Licenses and Permits”, published jointly by the New Jersey Department of
Health and Senior Services (NJDHSS) and New Jersey Department of Labor
(NJDOL) as N.J.A.C. 8:60 and 12:120; and the Department of Community Affairs
(DCA) N.J.A.C. 5:23 Subchapter 8 (educational facilities, public buildings, daycare center or nursery). These regulations pertain to licensing of asbestos abatement workers, supervisors and contractors and impose requirements relating to hazards to the public safety and health, during the removal, encapsulation, or disturbance of friable asbestos, or any handling of ACM that may result in the release of asbestos fibers.
All identified ACM which would be impacted by the planned renovation activities must be properly removed prior to performing such activities. The removal and disposal of ACM must be performed by a licensed asbestos handling contractor.
Sandy Hook Lifesaving Station Page 8
Gateway National Recreational Area
Highlands, Monmouth County, NJ
Langan Project No. 270039401
Proper notifications must be filed with the USEPA, State of New Jersey and other regulatory agencies prior to performing such activities.
Non-friable asbestos-containing floor tiles and exterior mastic around chimney were identified in the subject building. Refer to Table 1 for the details of asbestos survey findings.
This being a public building, abatement work inside the building is required to be performed in accordance with N.J.A.C. 5:23, Subchapter 8 regulations. The contractor has also an option to uses non-friable removal procedures. If non-friable removal option is used, the work shall be performed using the NJDHSS approved Resilient Floor Covering Institute’s (RFCI’s) removal procedures. The removal of non-friable ACM floor tiles and exterior mastic shall be performed using procedures which will not cause the building environment to become contaminated with airborne asbestos fibers.
Estimated costs for the abatement of all identified ACM are provided in Table 4.
8.2 Lead Based Paint
Based on the XRF screening results and a comparison of the data to the HUD guidelines, the following building components were identified painted with LBP:
Wooden Wall/Ceiling, Window and Door Components – Throughout
Plaster Walls – Throughout
Metal Radiator – Selected Locations
Refer to Table 3 for the XRF screening data.
Handling of any building components planned for demolition/renovations will require dust suppression and control relative to OSHA compliance and good industry practice to prevent fugitive dust exposure to personnel.
Please note that although the HUD defines lead based paint as paint having lead concentrations equal or greater than 1.0 mg/cm2, however, the Occupational
Safety and Health Administration (OSHA) considers any concentration of lead in
Sandy Hook Lifesaving Station Page 9
Gateway National Recreational Area
Highlands, Monmouth County, NJ
Langan Project No. 270039401 paint to be lead containing paint. Regardless of the lead concentrations in paint, the contractor shall comply with 29 CFR 1926.62, OSHA regulations, and take precautionary measures for dust control and limit employee exposure to lead dust during the renovations.
Regardless of the lead concentrations, painted surfaces that would be impacted by planned activities which include drilling, cutting, etc. and create dust should be properly addressed by following safe work practices and good housekeeping procedures. Grinding and sanding of paint without High Efficiency Particulate Air
(HEPA) filter exhaust, open flame gas fired torch, unconfined abrasive blasting, and chemical strippers containing methylene chloride or other human carcinogenic chemicals are not recommended.
The Federal Resource Conservation and Recovery Act (RCRA) regulation governs the handling, transportation, and disposal of hazardous materials. Every demolition/renovation debris generator has the responsibility to determine whether the debris exhibits one or more of the characteristic wastes listed in subpart C of 40 CFR Part 261. In the case of demolition debris, lead in LBP is a characteristic waste, and therefore, it is the responsibility of the renovation/demolition debris generator to characterize the waste prior to its disposal and, if found to be hazardous waste as defined by Federal Statutes, to be properly handled and disposed.
Metal objects painted with LBP are exempt from disposal regulations applicable to lead, provided they are properly recycled. Therefore, metal objects that are painted with LBP should be sent to a certified recycling facility.
8.3 Miscellaneous and Universal Wastes
Miscellaneous and universal wastes consisting of fluorescent light ballasts, fluorescent light bulbs, electrical/electronic devices, unknown chemicals, etc.
were identified in the building. Refer to Table 3 for an inventory of miscellaneous and universal waste articles identified in the building.
Miscellaneous and universal waste, which would require replacement/removal, will need to be properly recycled and/or disposed of at a landfill permitted to
Sandy Hook Lifesaving Station Page 10
Gateway National Recreational Area
Highlands, Monmouth County, NJ
Langan Project No. 270039401 accept such waste. The removal, handling, recycling, and disposal should be performed in accordance with applicable Federal, State, and local regulations.
8.4 Mold and Moisture Assessment
Based on our visual survey and the real time moisture measurements, the building components (i.e. drywall, wooden panels, plaster walls, and wooden floor elements) were observed fairly dry. No visible signs of apparent microbial growth or microbial odors were noted during our site visit. All surfaces in the building should be maintained in dry condition.
9.0 LIMITATIONS, EXCEPTIONS AND ASSUMPTIONS
Opinions and recommendations presented in this report apply to site conditions and features as they existed at the time of Langan’s site visit, and those reasonably foreseeable. They cannot necessarily apply to conditions and features of which Langan is unaware and has not had the opportunity to evaluate.
The conclusions presented in this report are professional opinions based solely upon
Langan’s visual observations of accessible areas, laboratory test data, and current regulatory requirements. These conclusions are intended exclusively for the purpose stated herein, at the site indicated, and for the project indicated.
This report has been prepared solely to discuss the findings of the data gathered during our survey which was conducted to address areas which were impacted by the storm surge.
It is important to recognize that even the most comprehensive scope of services may fail to detect all hazmat that may be associated with the property. Therefore, Langan cannot act as insurers and cannot “certify” that all hazmat associated with the property have been identified, and no expressed or implied representation or warranty is included or intended in our report, except that our services were performed, within the limits prescribed by our client, with the customary thoroughness and competence of our profession.
\\langan.com\data\AR\data4\270039401\Office Data\Reports\Environmental\Hazmat\2015_04_14 Final Hazmat Report.doc
Gateway National Recreational Area
Highlands, Monmouth County, NJ
TABLES
M a te ri a l
S a m p le
ID
L o c a ti o n F ri a b le
Y e s /N o N o te s /C o m m e n ts
-i n c h s q u a re t h in o liv e g re e n f lo o r ti le
N o g lu e
F T
-1 n d f lo o r
B a th ro o m b y s ta ir c a s e
A C
M C
H R
Y N o
S
F
-i n c h s q u a re s p a c k le d g ra y f lo o r ti le
A C
M C
H R
Y N o
G lu e a s s o c ia te d w it h f lo o r ti le s N o n
-A C
M N
D N o
M a s ti c a ro u n d c h im n e y
R o o f A s s u m d
A C
M
N o
S F
W a ll p la s te r (W h it e c o a t)
N o n -A
C M
N D
Y e s
W a ll p la s te r (B ro w n c o a t)
N o n -A
C M
N D
Y e s
C h im n e y w a ll p la s te r C
W P n d f lo o r N o n
-A C
M N
D Y e s
W a ll p la s te r B
W P
-1 B a s e m e n t
N o n -A
C M
N D
Y e s
B ri c k m o rt a r
B M
-1 B a s e m e n t a n d s t fl o o r
N o n -A
C M
N D
N o
G y p s u m b o a rd
S H
T -1
S c a tt e re d L o c a ti o n s t h ro u g h o u t
B u ild in g N o n
-A C
M N
D Y e s
C e ra m ic t ile g ro u t C
T G
-1 s t fl o o r
N o n -A
C M
N D
N o
F lu e p a tc h c e m e n t F
P C
-1 B a s e m e n t
N o n -A
C M
N D
N o
S ta ll in s u la ti o n S
I-s t fl o o r
N o n -A
C M
N D
N o
B o ile r ri b g a s k e t B
R G
-1 B a s e m e n t
N o n -A
C M
N D
N o
D a rk b la c k b ro w n b a s e b o a rd
N o n -A
C M
N D
N o
G lu e a s s o c ia te d w it h b a s e b o a rd
N o n -A
C M
N D
N o
S ta ir s te p s c o v e ri n g
N o g lu e S
S C
-1 S ta ir c a s e s t o n d a n d rd f lo o rs N o n
-A C
M N
D N o
F e lt p a p e r u n d e r w o o d e n s id in g F
E L
T -1
E x te ri o r
P e ri m e te r W a lls
/R o o fs
N o n -A
C M
N D
N o
C e ra m ic t ile g lu e
C T
G L
-1 s t fl o o r
N o n -A
C M
N D
N o
W in d o w g la zi n g
W G
-1 P e ri m e te r w a lls
N o n -A
C M
N D
N o
B la c k c o a ti n g o n w a ll u n d e r s t la y e r o f g y p s u m b o a rd
W M
A -1 s t fl o o r
N o n -A
C M
N D
N o
O ld e le c tr ic a l w ir e w ra p i n s u la ti o n W
I-
S c a tt e re d L o c a ti o n s t h ro u g h o u t
B u ild in g N o n
-A C
M N
D N o
A m a te ri a l w it h a s b e s to s c o n te n t g re a te r th a n o n e p e rc e n t
.0 is c o n s id e re d a s a n a s b e s to s -c o n ta in in g m a te ri a l (A
C M
C o n c e n tr a ti o n s i n w e ig h t p e rc e n t.
N
D
N o n e D e te c te d
A s b e s to s n o t d e te c te d i n s a m p le d m a te ri a l.
C
H R
Y
C h ry s o ti le
A s b e s to s
T A
B L
E
S
U M
M A
R Y
O F
A S
B E
S T
O S
S U
R V
E Y
F
IN
D
IN
G S
S a n d y H o o k L if e s a v in g S ta ti o n
/V is it o r C e n te r
S a n d y H o o k
N J
E s ti m a te d Q u a n ti ty o f
A C
M
A s s u m
S u rv e y R e s u lt s
B B
-1 n d f lo o r
B a th ro o m b y r o o m
F T
-2 n d f lo o r
B a th ro o m b y S to ra g e
R o o m
W P s t, n d a n d rd f lo o rs
S c a tt e re lo c a ti o n s
S F
Project Name: Action Level: 1.0 mg/cm
Survey Dates: 2/18/2015 -- Total Assays Reported: 55
Survey Component Substrate Color Test Location Total Lead Results Comments
ID# mg/cm
N/A N/A
N/A 1.1
N/A 0.9
1 Wall Plaster Silver Basement 0.15 Negative ---
2 Wall Plaster Silver Basement < LOD Negative ---
3 Wall Plaster Silver Basement 0.3 Negative ---
4 Beam Wood White Basement < LOD Negative ---
5 Beam Wood White Basement < LOD Negative ---
6 Stair Wood White Basement 0.05 Negative ---
7 Wall Wood White 1st Floor 8.6 Positive ---
8 Door Wood White 1st Floor 0.3 Negative ---
9 Door Frame Wood White 1st Floor 17.9 Positive ---
10 Wall Sheetrock Beige 1st Floor < LOD Negative ---
11 Wall Wood Beige 1st Floor 2.4 Positive ---
12 Wall Wood Beige 1st Floor < LOD Negative ---
13 Radiator Metal Silver 1st Floor 6.6 Positive ---
14 Wall Sheetrock Beige 1st Floor < LOD Negative ---
15 Door Wood Gray 1st Floor 3.3 Positive ---
16 Door Frame Wood Gray 1st Floor 15.1 Positive ---
17 Wall Wood White 1st Floor < LOD Negative ---
18 Beam Wood White 1st Floor 20.4 Positive ---
19 Ceiling Wood White 1st Floor 19.1 Positive ---
20 Wall Sheetrock Beige 1st Floor < LOD Negative ---
21 Wall Plaster White 1st Floor 43.7 Positive ---
22 Wall Plaster White 1st Floor 41.9 Positive ---
23 Wall Wood White 1st Floor 10.9 Positive ---
24 Wall Wood Gray 1st Floor 11.6 Positive ---
25 Column Wood White 1st Floor 0.4 Negative ---
26 Column Wood Gray 1st Floor 4.3 Positive ---
27 Window Frame Wood Gray 1st Floor 4.8 Positive ---
28 Window Sash Wood Gray 1st Floor 7.2 Positive ---
29 Floor Wood White 1st Floor < LOD Negative ---
30 Floor Wood White 1st Floor 0.4 Negative ---
31 Floor Wood White 1st Floor 0.3 Negative ---
32 Ceiling Wood White 1st Floor 10.4 Positive ---
33 Radiator Metal Gray 1st Floor < LOD Negative ---
34 Wall Wood Gray 1st Floor 8.6 Positive ---
35 Stair Wood Gray 1st Floor < LOD Negative ---
36 Stair-Post Wood Gray 1st Floor < LOD Negative ---
37 Window Frame Wood Gray 1st Floor 2.1 Positive ---
38 Window Sash Wood Gray 1st Floor < LOD Negative ---
39 Wall Sheetrock White 2nd Floor < LOD Negative ---
40 Wall Sheetrock White 2nd Floor < LOD Negative ---
41 Wall Plaster White 2nd Floor 21.8 Positive ---
42 Wall Plaster White 2nd Floor 19 Positive ---
43 Wall Plaster Blue 2nd Floor 18.2 Positive ---
TABLE 2 - XRF SCREENING RESULTS
Sandy Hook Lifesaving Station/Visitor Center
Sandy Hook, NJ
Site
Address:
Sandy Hook, NJ
Sandy Hook Lifesaving Station/Visitor Center
Shutter Calibration
Calibration
Project Name: Action Level: 1.0 mg/cm
Survey Dates: 2/18/2015 -- Total Assays Reported: 55
Survey Component Substrate Color Test Location Total Lead Results Comments
ID# mg/cm
TABLE 2 - XRF SCREENING RESULTS
Sandy Hook Lifesaving Station/Visitor Center
Sandy Hook, NJ
Site
Address:
Sandy Hook, NJ
Sandy Hook Lifesaving Station/Visitor Center
44 Beam Wood White 2nd Floor 10 Positive ---
45 Ceiling Wood White 2nd Floor 10 Positive ---
46 Wall Plaster White 2nd Floor 31.4 Positive ---
47 Wall Plaster White 2nd Floor 32.6 Positive ---
48 Wall Sheetrock White 3rd Floor 0.6 Negative ---
49 Wall Plaster White 3rd Floor 31.7 Positive ---
50 Window Frame Wood White 3rd Floor 10.2 Positive ---
51 Window Sash Wood White 3rd Floor 9.7 Positive ---
52 Stair Wood White 3rd Floor 2 Positive ---
53 Stair-Post Wood White 3rd Floor 0.04 Negative ---
54 Door Wood White 3rd Floor 9.4 Positive ---
55 Door Frame Wood White 3rd Floor 11 Positive ---
N/A 1.1
N/A 1.1
NEGATIVE = Negative Lead Result <LOD = Less than level of detection
POSITIVE = Positive Lead Result
DAILY CALIBRATIONS
Date: 2/18/2015
Calibration Check
Good
A rt ic le
/D e v ic e
U N
IV
E
R S
A L
W A
S T
E G
R O
U P
F lu o re s c e n t la m p s
U n it s t
M C
E T h e rm o s ta ts
U n it s
W A
S T
E C
O N
T A
IN
IN
G R
A D
IO
A
C T
IV
E
M A
T E
R
IA
L S
G
R O
U P
S m o k e d e te c to rs
U n it s
P C
B s C
O N
T A
IN
G
W A
S T
E
G R
O U
P
F lu o re s c e n t
L ig h t
B a lla s ts
U n it s t
E le c tr o n ic e q u ip m e n t c o n ta in in g c ir c u it b o a rd s w it h c a p a c it o rs s u c h a s C o m p u te rs a n
P ri p h e ra ls T e le p h o n e s T
V s e tc
U n it s
E le c tr ic a l m o to rs c o n ta in in g c a p a c it o rs a s s o c ia te d w it h p u m p s fa n s s h u tt e r d o o r o p e n e rs e tc
U n it s
W A
S T
E C
O N
T A
IN
IN
G C
F C s a n d
/o r
H C
F C s
G R
O U
P
E x te ri o r m o u n te d
A /C
H
V A
C A ir h a n d lin g c o o lin g u n it s
U n it s
R e fr ig e ra to r/
Ic e
M a c h in e
/W a te r C o o le r/
W a te r F o u n ta in /V e n d in g M a c h in e
U n it s
M
IX
E D
H A
Z A
R D
O U
S W
A S
T E
G R
O U
P
F ir e e x ti n g u is h e rs
U n it s
C h e m ic a ls
B o tt le s /C a n s
U n it s
B
IO
H A
Z A
R D
U n it
N e e d le W a s te
C o n ta in e r
U n it
A p p ro x Q u a n ti ty
D u e t o l iv e e le c tr ic it y a n d b u ild in g 's o p e ra ti o n s t h e b a lla s ts a s s o c ia te d w it h t h e l ig h t fi x tu re s a n d o th e r e le c tr ic a l d e v ic e s a re a s s u m e d t o c o n ta in P
C B s
E X
IT
s ig n s a n m o k e d e te c to rs a re a s s u m e d t o c o n ta in r a d io a c ti v e m a te ri a ls a n d h e a t tr a n s fo rm e r s y s te m s a re a s s u m e d t o c o n ta in C
F C s a n d /o r H
C F
C s
M C
E
M e rc u ry -C o n ta in in g E q u ip m e n t;
H
ID
H ig h I n te n s it y D is c h a rg e
M V
C
M e rc u ry V a p o r C o n ta in in g
H P
S
H ig h P re s s u re S o d iu m
M
H
M e ta l H a lid e
C F
C
C h lo ro d if lu o ro m e th a n e s
R -1
H C
F C s
H y d ro fl u o ro c a rb o n s
R -2
T A
B L
E
U
N
IV
E R
S A
L /H
A Z
A R
D O
U S
W A
S T
E I
N V
E N
T O
R Y
S a n d y H o o k L if e s a v in g S ta ti o n
/V is it o r C e n te r
S a n d y H o o k N
J
Material Location Survey
Results
Unit
Price $
Budgetary
Estimate
12-inch square thin olive green floor tile/ No glue 2nd floor - Bathroom by staircase ACM 10 SF $ 100 $ 1,000
9-inch square spackled gray floor tile ACM
Glue associated with floor tiles Non-ACM
Mastic around chimney Roof Assumed
ACM
25 SF $ 40 $ 1,000
$ 100 $ 2,500
ESTIMATED TOTAL FOR PROJECT MONITORING, AIR SAMPLE ANALYSIS, CLOSURE REPORT, AND SUBMITTAL REVIEW $ 2,500
TOTAL ASBESTOS ABATEMENT ESTIMATES FOR ALL OBSERVED AND CONCEALED ACM AND
ASSUMED ACM
$ 7,000
ASBESTOS ABATEMENT ESTIMATES FOR ALL OBSERVED AND CONCEALED ACM AND ASSUMED ACM $ 4,500
TABLE 4 - ASBESTOS ABATEMENT ESTIMATES
Sandy Hook Lifesaving Station/Visitor Center
Sandy Hook, NJ
Estimated Quantity of ACM/ Assumed
ACM
2nd floor - Bathroom by Storage Room 25 SF
Gateway National Recreational Area
Highlands, Monmouth County, NJ
DRAWINGS
Gateway National Recreational Area
Highlands, Monmouth County, NJ
A P P E N D I X A
Laboratory Test Results and Chain of Custody Documentations (Asbestos)
Gateway National Recreational Area
Highlands, Monmouth County, NJ
A P P E N D I X B
Langan’s Certifications and Laboratory Accreditations
Ny(AP- ^."u"W""\..ffi;National Voluntary Laboratory Accreditation Program
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
AmeriSci New York DBA: AmeriSci New York
117 E. 30th Street NewYork,NY 10016
Mr. Paul Mucha Phone: 212-679-8600 Fax: 212-679-27 11
E-Mail : pmucha@amerisci.com URL: http://rwr,v.amerisci.com
BULK ASBESTOS FIBER ANALYSIS (PLM) NVLAPLABCODE 200546-0
Designation / Description
EPA 600/M4-82-020: Interim Method for the Determination of Asbestos in Bulk Insulation Samples
EPA 600,R-93/116: Method for the Determination of Asbestos in Bulk Building Materials
NVI.IIP Code
18/A01
18/A03
Effective dates
Page 1of 1
201 4-07 -01 through 20 I 5-06-30 tu fl ,tl,t-LQ For the National lnstitute of Standards and Technology
NVLAP-o1S (REV. 2005.05-19)
UI
v.
(J o-l z o.)
o e e o
(D a q
a) ltt
(g oa q)
,P
?s
SI
FE
N b fl FE' Y F a
^t o sa' u E { 8 , E A O N
E { S tI ; . E e r g E E G : O E 6 i E > 6 e * 5 - ) E ; ' d o ^ Q H { E t s s # i : e F s SE 5 E * J E F sR F > - E * X i E s. : i > z E H f , . s x . .
e a r u S t = b t s 5 z E S € I - R I g : ' 5 F E $ k [ t + 3 ? i ! { F i s a ; i z F e 3 : B E I E S i E H E * = 2 -i e E V T i E' ) i I . \< c )
- h -c e * t i* -i . F x 8x x ;
E i r 8 E Q" i F e
- * E
- . p l'-sd^- ""'z iFffi} z t'- 6 tn* r uono ut g) o a q) h
F-
N
ItO o oql 1() o N F
O
IIJ
o I o c o t -
{r,(E .E !t o l-o o lts o o
{d(u o t -tF.E L oo
@ - l t=l!
E:J I z t o)o ,cl 6 o - c t r o E P 9 o\., c tF Cto o t s E o c t t r E
F So-u, O u -o o o o o = g E A o
- c o -t ( s c c : . 9 z
File details come from the government source that posted it. Updated .