140P2018R0026_AMD_1.pdf
PDF 598 KB Posted
- Attached to
- VAFO 211497 - Rehab Visitors Center
- Solicitation number
- 140P2018R0026
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 140P2018R0026_AMD_4.pdf | ||
| 140P2018R0026_AMD_3_Drawings.pdf | ||
| 140P2018R0026_AMD_3.pdf | ||
| 140P2018R0026_AMD_2.pdf | ||
| AMD_1_SPECS.pdf | ||
| AMD_1_PRE_PROP_AGND.pdf | ||
| AMD_1_SIGN_IN_SHEET.pdf | ||
| AMD_1_DWGS.pdf | ||
| Attach_3_Sub_Plan.docx | DOCX document | |
| Attach_1_Exp_Form.docx | DOCX document | |
| Attach_6_Dwgs.pdf | ||
| 140P2018R0026_Solicitation.pdf | ||
| Attach_2_PPQ_Form.docx | DOCX document | |
| Attach_5_Spec_Vol_2.pdf | ||
| Attach_4_Spec_Vol_1.pdf | ||
| B01_PRESOL.docx | DOCX document |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE
2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NUMBER IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
Previous edition unusable
140P2018R0026 AMENDMENT 00001 VALLEY FORGE NHP VISITOR CENTER REHABILITATION VAFO 211497
Specification Revisions
1. REPLACE Specification Section 000110 TABLE OF CONTENTS in its entirety with the attached Specification Section 000110 TABLE OF CONTENTS, Rev. 1.
2. REPLACE Specification 042200 CONCRETE UNIT MASONRY, in its entirety with the attached Specification Section 042200 CONCRETE UNIT MASONRY, Rev. 1.
3. REPLACE Specification 055000 METAL FABRICATIONS, in its entirety with the attached Specification Section 055000 METAL FABRICATIONS, Rev. 1.
4. REPLACE Specification 064113 WOOD AND PLASTIC-FACED ARCHITECTURAL
CABINETS, in its entirety with the attached Specification Section Specification 064113 WOOD AND PLASTIC-FACED ARCHITECTURAL CABINETS, Rev. 1.
5. REPLACE Specification 084229.33 SWINGING AUTOMATIC ENTRANCES, in its entirety with the attached Specification Section Specification 084229.33 SWINGING AUTOMATIC ENTRANCES, Rev. 1.
6. REPLACE Specification 087100 DOOR HARDWARE, in its entirety with the attached
Specification Section Specification 087100 DOOR HARDWARE, Rev. 1.
7. REPLACE Specification 101423 PANEL SIGNAGE, in its entirety with the attached Specification Section Specification 101423 PANEL SIGNAGE, Rev. 1.
8. ADD attached Specification 102113.17 PHENOLIC CORE TOILET COMPARTMENTS, in its entirety.
9. REPLACE Specification 102800 TOILET, BATH AND LAUNDRY ACCESSORIES, in its entirety with the attached Specification Section Specification 102800 TOILET, BATH AND LAUNDRY ACCESSORIES, Rev. 1.
10. ADD attached Specification 270530 INNERDUCT FOR COMMUNICATIONS SYSTEMS, in its entirety.
11. ADD attached Specification 270533 CONDUITS, PULLBOXES AND BACKBOXES FOR COMMUNICATIONS SYSTEMS, in its entirety.
12. ADD attached Specification 270553 IDENTIFICATION FOR COMMUNICATION SYSTEMS, in its entirety.
13. ADD attached Specification 270637 FIRESTOPPING FOR COMMUNICATIONS
SYSTEMS, in its entirety.
14. ADD attached Specification 270800 TESTING OF COMMUNICATIONS SYSTEMS, in its entirety.
15. ADD attached Specification 271000 STRUCTURED CABLING, in its entirety.
16. ADD attached Specification 271116 COMMUNICATIONS CABINETS, RACKS, FRAMES AND ENCLOSURES, in its entirety.
17. ADD attached Specification 271119 COMMUNICATIONS TERMINATION BLOCKS
AND PATCH PANELS, in its entirety.
18. ADD attached Specification 271123 COMMUNICATIONS CABLE MANAGEMENT AND RUNWAY, in its entirety.
19. ADD attached Specification 271513 COPPER HORIZONTAL CABLING, in its entirety.
20. ADD attached Specification 271543 COMMUNICATIONS FACEPLATES AND
CONNECTORS, in its entirety.
21. ADD attached Specification 271619 COMMUNICATIONS PATCH CORDS AND STATION CORDS, in its entirety.
22. REPLACE Specification 280000 SECURITY GENERAL SYSTEM REQUIREMENTS, in its entirety with the attached Specification Section Specification 280000 SECURITY GENERAL SYSTEM REQUIREMENTS, Rev. 1.
23. REPLACE Specification 282300 VIDEO SURVEILLANCE MANAGEMENT SYSTEM, in its entirety with the attached Specification Section Specification 282300 VIDEO SURVEILLANCE MANAGEMENT SYSTEM, Rev. 1.
24. REPLACE Specification 321313 CONCRETE PAVING, in its entirety with the attached
Specification Section Specification 321313 CONCRETE PAVING, Rev. 1.
Construction Drawings Revisions
Drawing Number 464/141261 – RehabilitateVisitor Center For Energy Efficiency, Safety and ADA Access
5. Sheets 1, 2, 3, 4, 8, 12, 13, 14, 15, 17, 22, 25, 28, 34, 37, 38, 39, 40, 41, 44, 46, 47, 48, 50, 51, 52, 54, 55, 56, 57, 58, 63, 72, 73, 79, 83, 86, 87, 88, 89, 92, 102, 104, 112, 113, 114, 115, 117, 119, 122, 124, 131, 132, 139, 140, 151, 152, 153, 155, 156, 157, 160, 161, 168.
DELETE in entirety, and SUBSTITUTE the attached revised sheets: 1A, 2A, 3A, 4A, 8A, 12A, 13A, 14A, 15A, 17A, 22A, 25A, 28A, 34A, 37A, 38A, 39A, 40A, 41A, 44A, 46A, 47A, 48A, 50A, 51A, 52A, 54A, 55A, 56A, 57A, 58A, 63A, 72A, 73A, 79A, 83A, 86A, 87A, 88A, 89A, 92A, 102A, 104A, 112A, 113A, 114A, 115A, 117A, 119A, 122A, 124A, 131A, 132A, 139A, 140A, 151A, 152A, 153A, 155A, 156A, 157A, 160A, 161A, 168A.
Note that sheet 63/63a (Drawing GL.5) is Not in Contract.
Clarifications
Q1. Is there an existing green roof or is a new one to be installed?
A1. A portion of the building is sub-terrain and is covered with soil and grass, however it is not a “green roof” in the modern day sense. There is no green roof to be installed.
Q2. Security General System Requirements Section 280000. 1.9.C
4. Contractor shall have permanent offices and factory trained personnel to install and service the security system within twenty-five (25) miles of the jobsite. Does this statement disqualify any security integrator contractor that has permanent offices greater than 25 miles for the jobsite?
A2. Contractor shall have permanent offices and factory trained personnel to install and service the security system within one-hundred (100) miles of the jobsite. Specification section has been revised.
| 140P2018R0026_AMD_1 |
| Amendment 1 Text |
| Q2. Security General System Requirements Section 280000. 1.9.C 4. Contractor shall have permanent offices and factory trained personnel to install and service the security system within twenty-five (25) miles of the jobsite. Does this statement disqua... |
| A2. Contractor shall have permanent offices and factory trained personnel to install and service the security system within one-hundred (100) miles of the jobsite. Specification section has been revised. |
| topmostSubform[0]: |
| Page1[0]: |
| AmendmentNo[0]: AMENDMENT 00001 |
| Code[0]: PDS |
| Code[1]: |
| AccountingData[0]: |
| A13[0]: |
| C13[0]: |
| D13[0]: |
| NameandTitleSigner[0]: |
| NameandTitleOfficer[0]: |
| Description[0]: The subject amendment 00001 for solicitation 140P2018R0026 for the construction solicitation to rehabilitate the Valley Forge National Historic Park Visitor Center, King of Prussia, PA is summarized on pages 2, 3 and 4 of this document. Page 4 answers the questions received to date. The attachments include the revised specification sections and drawings and the sign-in sheet and the agenda for the on-site pre-proposal meeting held on site on August 1, 2018. The questions, answers and notes from the meeting will be posted in a forthcoming amendment. |
| FacilityCode[0]: |
| Code[2]: |
| IssuedBy[0]: NPS, DSC CONTRACTING SERVICES DIV |
12795 W. ALAMEDA PKWY
P.O. BOX 25287
DENVER, CO 80225-0287
| NameandAddress[0]: |
| AdministeredBy[0]: |
| ContractIDCode[0]: 140P2018R0026 |
| ReqNumber[0]: |
| AmendmentNo[1]: 140P2018R0026 |
| ModificationNo[0]: |
| ProjectNo[0]: VAFO 211497 |
| Page[0]: 1 |
| Pages[0]: 4 |
| EffectiveDate[0]: 08/02/2018 |
| Dated9B[0]: |
| Dated10B[0]: |
| CheckBox9[0]: 1 |
| CheckBox10[0]: Off |
| CheckBox11[0]: 1 |
| CheckBox13A[0]: Off |
| CheckBox13B[0]: Off |
| CheckBox13C[0]: Off |
| CheckBox13D[0]: Off |
| IsNot[0]: Off |
| Is[0]: Off |
| Extended[0]: Off |
| NotExtended[0]: 1 |
| DateSigned[0]: |
| DateSigned[1]: |
| Copies[0]: 1 |
| CopiesReturned[0]: |
File details come from the government source that posted it.