NIFC_300_JWH_Standby_-_E101_E600_E601_Rev1_0001.pdf
PDF 2 MB Posted
- Attached to
- NIFC 300 JWH STANDBY AND EMERGENCY POWER
- Solicitation number
- 140L3725R0002
About this file
This document contains electrical engineering design drawings for a Bureau of Land Management project at the NIFC (National Interagency Fire Center) Campus in Boise, Idaho, specifically focused on standby and emergency power systems. The drawings (E-101, E-600, and E-601) detail a comprehensive electrical infrastructure upgrade involving demolition and new work for power distribution, including a 600KW/750KVA standby generator, emergency distribution switchboard, and multiple electrical panels with specific power requirements.
Key technical specifications include replacing existing electrical infrastructure with new equipment configurations, integrating power metering devices from Schneider Electric, and implementing precise power distribution across various panels and systems. The project involves complex electrical work with specific requirements such as service interruptions limited to 8 hours outside regular office hours, compliance with NEC standards, and a one-year power metering service contract. The project is associated with Solicitation Number 140L3725R0002 and is being executed by the Department of the Interior's Bureau of Land Management Idaho Region.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5 6 7 8 9 10 11 1312
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
2A
GDBMTS
1. EXISTING 600 KW GENERATOR, FIELD COORDINATE
PATHW AYS FOR NEW CONNECTIONS AS SHOWN ON THE
ONE-LINE DIAGRAM.
2. PROPOSED LOCATION OF MTS AND GDB, COORDINATE
LOCATION WITH EXISTING CONDITIONS PRIOR TO ROUGH-IN.
3. APPROXIMATE ROUTE FROM OUTDOOR GEAR TO AUTOMATIC
TRANSFER SWITCHES LOCATED IN BASEMENT ELECTRICAL
ROOM. REFER TO SHEET E-601 FOR CONDUIT AND
CONDUCTOR SIZING. CONTRACTOR TO UTILIZE EXISTING
UNISTRUT RACKING AND FOLLOW PATHWAY OF EXISTING
CONDUIT. PROVIDE ADDITIONAL UNISTRUT RACKING AS
REQUIRED FOR CONNECTIONS SHOW N.
4. FIELD COORDINATE PENETRATION LOCATION OF BASEMENT
EXTERIOR WALL FOR ACCESS TO BASEMENT ELECTRICAL
ROOM. COORDINATE WITH OTHER TRADES AS REQUIRED
FOR PATCH AND REPAIR.
# KEYNOTES
GENERAL NOTES
A. COMPLY WITH LATEST ADOPTED NEC AND APPLICABLE
CODES/STANDARDS.
B. SHARED NEUTRALS ARE NOT ALLOWED FOR SINGLE PHASE
BRANCH CIRCUITS.
C. FIRE CAULK ALL NEW PENETRATIONS MADE TO FIRE RATED
WALLS TO MAINTAIN FIRE RATING.
D. SERVICE INTERRUPTIONS OF BUILDING ELECTRICAL
SYSTEMS SHALL ONLY OCCUR OUTSIDE OF REGULAR OFFICE
HOURS AND BE LIMITED TO 8 HOURS OUR LESS. ELECTRICAL
SERVICE SHUTDOWN SCHEDULE SHALL BE APPROVED BY
THE GOVERNMENT.
E. ELECTRICAL CONTRACTOR SHALL ADJUST PROGRAMMING
OF SCHNEIDER ELECTRIC PME POWER METERING DEVICES
AND SOFTWARE FOR ALL CHANGES TO THE POWER
METERING, USING MANUFACTURER AUTHORIZED SUPPORT,
AND PROVIDE A ONE YEAR SCHNEIDER ELECTRIC PME
POW ER METERING SERVICE CONTRACT FOR THE LOCAL
CAMPUS SERVER HOSTED PLATFORM UPON COMPLETION OF
THE PROJECT.
1 2 3 4 5
D
C
B
A
S h e e t T it le
D e s ig n e d b y
D ra w n b y
C h e c k e d b y
A p p ro v e d b y
R e v is io n s
U n it e d S ta te s D e p a rt m e n t o f th e
I n te ri o r
B u re a u o f L a n d M a n a g e m e n t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
/1
/2
:1
:1
P
M C
U s e rs
\t y le rv ic to ri n o \D o c u m e n ts
R e v it L o c a lT e m p \L
B Y
D B
L M
T
O e le c ty le rv ic to ri n o .r v t
F
IR
S T
F L
O O
R P
O W
E R
P L
A N
V
IC
T O
R
IN
O
H E
S T
A N
D
V
IC
T O
R
IN
O
H E
S T
A N
D
N
IF
C
-J W
H S
T A
N D
B Y
A N
D E
M E
R G
E N
C Y
P O
W E
R
N
IF
C C
A M
P U
S
S
D E
V E
L O
P M
E N
T A
V E
B O
IS
E
ID
140L0619D0008
LBYDBLM24_TO21
11.15.2024
E-101
6 9
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
A1
FIRST FLOOR POW ER PLAN
N
0 8' 16' 32'
D es cr ip tio n D at e
R ev is io n
3/
/2
14056
HADIFOET
AT
OSTY LER B. V ICTO
RI
RE
EN
IG
NELANOISSEFORP
DESNECIL
NO
M
PANEL
HE
PANEL
LE
PANEL
LF
(2 SECT.)
PANEL
LC
(2 SECT.)
PANEL
LD
(2 SECT.)
PANEL
LB
PANEL
LA-2
PANEL
LA-3
PANEL
LA-1
PANEL
HC
PANEL
HB
PANEL
HD
PANEL
HF
PANEL
HA
M
G
SPD
MOTOR
CONTROL
CENTER
"MCC"
ELEVATOR
CNTRLR
M M
IB1
(N.C.)
IB2
(N.C.)
UPS 1
BATTERY UPS 1
UPS 2
BATTERY UPS 2
M
PANEL
LED
PANEL
LEC
PDU
1A
PDU
PDU
3A
PDU
PDU
PDU
200A
LPS-RK
200/3
200A
LPS-RK
200/3
150A
LPS-RK
200/3
250A
FRS-R
400/3
250A
FRS-R
400/3
150A
LPS-RK
200/3
200A
LPS-RK
200/3 200/3
100A
LPS-RK
100/3
750A
KRP-C
800/3
45/3
30KVA
480/3 TO
208Y/120
400/3 400/3
AHU-1
480/3
AHU-2
480/3
60/3
45KVA
480/3 TO
208Y/120
60/3
45KVA
480/3 TO
208Y/120
60/3
45KVA
480/3 TO
208Y/120
60/3
45KVA
480/3 TO
208Y/120
75KVA
480/3 TO
208Y/120
600KW/750KVA;
480Y/277 3ϕ, 4W
STANDBY
GENERATOR
(E) 800A 4P
ATS
100/3
150/3
LA-42
HA-10
HA-9,11,13,
15,17,19
EXT. LGT.
BLDG. SEC.
LGT.
20A 2P LTG
CONTACTOR
20A 2P LTG
CONTACTOR
20A 4P LTG
CONTACTOR
(6)4" C'S. EACH W /
4-500MCM (CU)
2000/3
SOLID STATE
W/ADJUST. TRIP
& GRND. FAULT
4 #3/0(CU)
& 1 #6(G)-2"
4 #1/0(CU)
& 1 #6(G)-2"
3 #250MCM
(CU) & 1
#4(G)-2"
4 #1/0(CU)
& 1 #6(G)-2"
4 #3/0(CU)
& 1 #6(G)-2"
3 #250MCM
(CU) & 1
#4(G)-2"
3 #3 & 1 #8(G)-1"
3 #1/0(CU); 1
#3/0(CU)(N) &
1 #6(G)-2"
3 #2/0, #4/0 & 1 #6(G)-2"
3 #2/0, #4/0 & 1 #6(G)-2"
(6) #12-3/4"C
(2) SETS OF
(4) 600MCM(CU)
& (1) 2/0 GND
4-3(CU) &
1-8(G)-1 1/4"
3-8 & 1-10-3/4"
4-3(CU) &
1-8(G)-1 1/4"
3 #6 & 1 #10(G)-3/4"
3 #1/0(CU);
1 #1/0(CU)(N)
& 1 #6(G)-2"
4 #3/0(CU)
& 1 #6(G)-2"
3 1/2"C'S.
4-500MCM(CU)
& 1-1/0(G)
(2)3 1/2"C'S.
4-500MCM(CU)
& 1-1/0(G)
NEUTRAL
1#3/0(CU)-3/4"
WATER
SERVICE
20' of 3/0 B.C.
IN BOTTOM OF
FOOTING
SS
SS
A
V
300-JWH
ENERGY CONSUMPTION
METER 7350
150/3
G N
CB-1
150/3
150/3
150/3
TO E.F.'S 1,2,3,4
ON ROOF
20A 4P
CONTACTOR
T C
'3R' '3R'
150/3 150/3
100/3
SPARE
1 1111 11
MSB: 480Y/277V, 3ϕ, 4W.
2000A, 75,000 AIC
TO IDAHO POWER
UTILITY TRANSFORMER
300-JWH
EMERGENCY
DIST PANEL
METER PMD-850
100A100A
100/3
60A60A60A60A100A100A60A60A100A100A400A450A
100/3100/3100/3100/3100/3100/3100/3100/3100/3100/3100/3600/3600/3
1000/4
DRY COOLERS 480/3 EACH
30/3
20A.FRS
'3R'
PUMP-3
480/3
PUMP-4
480/3
300KVA
480/3 TO
208Y/120
UPSDSB
EMERGENCY
DISTRIBUTION
SWITCHBOARD
100/3100/3
100 A 100 A
S S S S
EMERG.
OFF
EMERG.
SHUT
OFF
60/3
CAC-3
EMERG.
SHUT
OFF
100/3
VAV BOX
EMERG.
SHUT
OFF
60/3
CAC-2
EMERG.
SHUT
OFF
60/3
CAC-1
EMERG.
SHUT
OFF
60/3
CAC-5
3-4 & 1-8(G)-1"
3-4 & 1-8(G)-1"
3-8 & 1-10(G)-3/4"
3-8 & 1-10(G)-1"
SIZE '2'
W/HOA
3-6(CU) &
1-8(G)-1"
3-3(CU) &
1-8(G)-1 1/4"
3-12 & 1-12(G)-3/4"
3"C'S EA. W/
4-400MCM(CU) & 1-3/0(G)
3-2(CU); 1-1/0(CU)
(N) & 1-6(G)-1 1/2"
4-3/0(CU); &
1-6(G)-2"
EMERG.
OFF
EMERG.
OFF
EMERG.
OFF
3-4 & 1-8(G)-1"
3-4 & 1-8(G)-1"
PUE METER
DISCONNECT
3-4 & 1-8(G)-1"
600A800/3
W.P.
ELEVATOR
30HP; 480/3
150/3
SHUNT
TRIP IN
NEMA1
TO F.A.
SYSTEM
HEAT
DETECTORS
S
FA
300-JWH
MCC ENERGY
CONSUMPTION
METER PMD-5110
300-JWH
ELEVATOR ENERGY
CONSUMPTION
METER PMD-5110
(2)2"C'S EA. W/ 3-4/0(CU)
& 1-2(G)
(2)2"C'S EA. W/ 3-3/0(CU)
& 1-3(G)
225A 225A
4-3/0(CU) & 1-3(G) 4-3/0(CU) & 1-3(G)
MB1
(N.C.)
200A
MB2
(N.C.)
200A
MBP
(N.O.)
400A
MIS
(N.C.)
400A
3-3/0(CU) & 1-6(G)
2" C.
3-4/0(CU) & 1-4(G), 2" C.
SHIELDED CABLE
(2) 2" C. EACH WITH
3-3/0(CU) & 1-3(G)
300-JWH
IT EQUIP ENERGY
METER PMD-5560
100 A 100 A
1. REMOVE EXISTING FUSIBLE SWITCH AND ASSOCIATED
CONNECTION. MAINTAIN CONDUIT AND CONDUCTORS TO
DOWNSTREAM EQUIPMENT TO THE FURTHEST EXTEND
POSSIBLE FOR RECONNECTION, REFER TO NEW WORK ONE-
LINE DIAGRAM. FIELD COORDINATE SPLICING OF NEW WORK
WITHIN EXISTING SWITCHGEAR SECTION.
2. REMOVE FUSE WITHIN SWITCHBOARD, DOWNSTREAM
CONDUIT CONDUCTORS TO REMAIN, REFER TO SHEET E-601
FOR NEW FUSE RATING.
3. EXISTING CONNECTION TO BE REMOVED. EXISTING CONDUIT
TO REMAIN FOR REUSE AS PER SHEET E-601. REMOVE ANY
UNUSED RACEWAYS.
4. REMOVE EXISTING CONNECTION FROM ATS TO EXISTING PULL
BOX LOCATED ADJACENT TO EMERGENCY DISTRIBUTION
SWITCHBOARD. PULL BOX TO REMAIN FOR REUSE.
# KEYNOTES
GENERAL NOTES
A. COMPLY WITH LATEST ADOPTED NEC AND APPLICABLE
CODES/STANDARDS.
B. SHARED NEUTRALS ARE NOT ALLOWED FOR SINGLE PHASE
BRANCH CIRCUITS.
C. FIRE CAULK ALL NEW PENETRATIONS MADE TO FIRE RATED
WALLS TO MAINTAIN FIRE RATING.
D. SERVICE INTERRUPTIONS OF BUILDING ELECTRICAL
SYSTEMS SHALL ONLY OCCUR OUTSIDE OF REGULAR OFFICE
HOURS AND BE LIMITED TO 8 HOURS OUR LESS. ELECTRICAL
SERVICE SHUTDOWN SCHEDULE SHALL BE APPROVED BY
THE GOVERNMENT.
E. ELECTRICAL CONTRACTOR SHALL ADJUST PROGRAMMING
OF SCHNEIDER ELECTRIC PME POWER METERING DEVICES
AND SOFTWARE FOR ALL CHANGES TO THE POWER
METERING, USING MANUFACTURER AUTHORIZED SUPPORT,
AND PROVIDE A ONE YEAR SCHNEIDER ELECTRIC PME
POW ER METERING SERVICE CONTRACT FOR THE LOCAL
CAMPUS SERVER HOSTED PLATFORM UPON COMPLETION OF
THE PROJECT.
LINE TYPE LEGEND
EXISTING
NEW
DEMO
1 2 3 4 5
D
C
B
A
S h e e t T it le
D e s ig n e d b y
D ra w n b y
C h e c k e d b y
A p p ro v e d b y
R e v is io n s
U n it e d S ta te s D e p a rt m e n t o f th e
I n te ri o r
B u re a u o f L a n d M a n a g e m e n t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
/1
/2
:1
:1
P
M C
U s e rs
\t y le rv ic to ri n o \D o c u m e n ts
R e v it L o c a lT e m p \L
B Y
D B
L M
T
O e le c ty le rv ic to ri n o .r v t
D E
M O
L
IT
IO
N
O N
E -L
IN
E
D
IA
G R
A M
V
IC
T O
R
IN
O
H E
S T
A N
D
V
IC
T O
R
IN
O
H E
S T
A N
D
N
IF
C
-J W
H S
T A
N D
B Y
A N
D E
M E
R G
E N
C Y
P O
W E
R
N
IF
C C
A M
P U
S
S
D E
V E
L O
P M
E N
T A
V E
B O
IS
E
ID
140L0619D0008
LBYDBLM24_TO21
11.15.2024
E-600
7 9
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
A1
DEMOLITION ONE-LINE DIAGRAM
D es cr ip tio n D at e
R ev is io n
3/
/2
14056
HADIFOET
AT
OSTY LER B. V ICTO
RI
RE
EN
IG
NELANOISSEFORP
M
MOTOR
CONTROL
CENTER
"MCC"
ELEVATOR
CNTRLR
PANEL
HE
PANEL
LE
PANEL
LF
(2 SECT.)
PANEL
LC
(2 SECT.)
PANEL
LD
(2 SECT.)
PANEL
LB
PANEL
LA-2
PANEL
LA-3
PANEL
LA-1
M M
M
PANEL
HC
PANEL
HB
PANEL
HD
PANEL
HF
PANEL
HA
M
G
SPD
SPD
600A 3P
200A 3P
150A 3P
250A 3P
250A 3P
150A 3P
200A 3P
200A 3P
200A 3P
SPARE
200A 3P
SPARE
J
IB1
(N.C.)
IB2
(N.C.)
UPS 1
BATTERY UPS 1
UPS 2
BATTERY UPS 2
PANEL
LED
PANEL
LEC
PDU
1A
PDU
PDU
3A
PDU
PDU
PDU
100A100A
100/3
60A60A60A60A100A100A60A60A100A100A400A450A
100/3100/3100/3100/3100/3100/3100/3100/3100/3100/3100/3600/3600/3
DRY COOLERS 480/3 EACH
30/3
20A.FRS
'3R'
PUMP-3
480/3
PUMP-4
480/3
45/3
30KVA
480/3 TO
208Y/120
400/3 400/3
AHU-2
480/3
AHU-1
480/3
60/3
45KVA
480/3 TO
208Y/120
60/3
45KVA
480/3 TO
208Y/120
60/3
45KVA
480/3 TO
208Y/120
60/3
45KVA
480/3 TO
208Y/120
75KVA
480/3 TO
208Y/120
EMERGENCY
DISTRIBUTION
SWITCHBOARD
MSB: 480Y/277V, 3ϕ, 4W.
2000A, 75,000 AIC
600KW, 750KVA;
480Y/277 3ϕ, 4W
STANDBY
GENERATOR
(E) 800A 4P
ATS
100/3
150/3
EMERG.
SHUT
OFF
60/3
CAC-3
EMERG.
SHUT
OFF
100/3
VAV BOX
EMERG.
SHUT
OFF
60/3
CAC-2
EMERG.
SHUT
OFF
60/3
CAC-1
EMERG.
SHUT
OFF
60/3
CAC-5
LA-42
HA-10
HA-9,11,13,
15,17,19
EXT. LGT.
BLDG. SEC.
LGT.
20A 2P LTG
CONTACTOR
20A 2P LTG
CONTACTOR
20A 4P LTG
CONTACTOR
(6)4" C'S. EACH W /
4-500MCM (CU)
2000/3
SOLID STATE
W/ADJUST. TRIP
& GRND. FAULT
4#3/0, 1#6
GND IN 2" C.
4#1/0, 1#6
GND IN 2" C.
3#250, 1#4
GND IN 2" C.
4#1/0, 1#6
GND IN 2" C.
4#3/0, 1#6
GND IN 2" C.
3#250, 1#4
GND IN 2" C.
3 #3 & 1 #8(G)-1"
3 #1/0(CU); 1
#3/0(CU)(N) &
1 #6(G)-2"
3 #2/0, #4/0 & 1 #6(G)-2"
3 #2/0, #4/0 & 1 #6(G)-2"
(6) #12-3/4"C
CONTROL CONDUCTORS
(2) SETS OF 4" C. EACH
WITH 4#600, 1#2/0 GND
3-4 & 1-8(G)-1"
3-4 & 1-8(G)-1"
3-8 & 1-10(G)-3/4"
3-8 & 1-10(G)-1"
4#3, 1#8 GND
IN 1-1/4" C.
3-8 & 1-10-3/4"
4-3(CU) &
1-8(G)-1 1/4"
SIZE '2'
W/HOA
3-6(CU) &
1-8(G)-1"
3-3(CU) &
1-8(G)-1 1/4"
3-12 & 1-12(G)-3/4"
3 #6 & 1 #10(G)-3/4"
3 #1/0(CU);
1 #1/0(CU)(N)
& 1 #6(G)-2"
3-4 & 1-8(G)-1"
3-4 & 1-8(G)-1"
4#3/0, 1#6
GND IN 2" C.
PUE METER
DISCONNECT
3-4 & 1-8(G)-1"
(2) SETS OF 3" C. EACH
WITH 4#350, 1#1 AWG GND
(2)3 1/2"C'S.
4-500MCM(CU)
& 1-1/0(G)
800/3 100/3
600A800/3
GENERATOR
CONNECTOR
800A 3P
NEUTRAL
1#3/0(CU)-3/4"
WATER
SERVICE
20' of 3/0 B.C. IN BOTTOM
OF FOOTING
SS
SS
A
V
300-JWH ENERGY
CONSUMPTION METER 7350
150/3
G N
CB-1
150/3
150/3
150/3
TO E.F.'S 1,2,3,4
ON ROOF
20A 4P
CONTACTOR T
C
'3R' '3R'
150/3 150/3
100/3
W.P.
ELEVATOR
30HP; 480/3
150/3
SHUNT
TRIP IN
NEMA1
TO F.A.
SYSTEM
HEAT
DETECTORS
S
FA
200/3
100A
LPS-RK
100/3
800A
KRP-C
800/3
100A
LPS-RK
TO IDAHO POWER
UTILITY TRANSFORMER
SECONDARY
DISTRIBUTION BOARD
'SDB': 480Y/277V, 3ϕ, 4W.
800A, 65,000 AIC
GENERATOR
DISTRIBUTION BOARD
'GDB': 480Y/277V, 3ϕ, 4W.
1000A, 65,000 AIC
NEMA 3R
MTS: 480Y/277V, 4P
100A, 65,000 AIC
NEMA 3R
ATS2: 480Y/277V, 4P
100A, 65,000 AIC
(2) SETS OF 3-1/2" C. EACH
WITH 4#500MCM, 1#1/0 GND
4#3, 1#8 GND
IN 1-1/4" C.
4#3, 1#8 GND
IN 1-1/4" C.
(2) SETS OF 3-1/2" C. EACH
WITH 4#500MCM, 1#1/0 GND
1 1 1 1 1 1 1
300-JWH
EMERGENCY
DIST PANEL
METER PMD-850
300-JWH
MCC ENERGY
CONSUMPTION
METER PMD-5110
300-JWH
ELEVATOR ENERGY
CONSUMPTION
METER PMD-5110
300-JWH
IT EQUIP ENERGY
METER PMD-5560
(2)2"C'S EA. W/ 3-4/0(CU)
& 1-2(G)
(2)2"C'S EA. W/ 3-3/0(CU)
& 1-3(G)
225A 225A
4-3/0(CU) & 1-3(G) 4-3/0(CU) & 1-3(G)
MB1
(N.C.)
200A
MB2
(N.C.)
200A
MBP
(N.O.)
400A
MIS
(N.C.)
400A
3-3/0(CU) & 1-6(G)
2" C.
3-4/0(CU) & 1-4(G), 2" C.
SHIELDED CABLE
(2) 2" C. EACH WITH
3-3/0(CU) & 1-3(G)
1000/4
300KVA
480/3 TO
208Y/120
UPSDSB
100/3100/3
100 A 100 A
S S S S
EMERG.
OFF
3"C'S EA. W/
4-400MCM(CU) & 1-3/0(G)
3-2(CU); 1-1/0(CU)
(N) & 1-6(G)-1 1/2"
4-3/0(CU); &
1-6(G)-2"
EMERG.
OFF
EMERG.
OFF
EMERG.
OFF
100 A 100 A
1. INTERCEPT EXISTING CONDUCTORS AND EXTEND AS
REQUIRED TO RECONNECT EQUIPMENT SHOWN. MAKE
SPLICE IN EXISTING MAIN SWITCHBOARD SECTION MADE
VACANT BE DEMOLITION.
2. INSTALL 100A/3-PHASE PIN & SLEEVE STYLE CONNECTOR
ADJACENT TO MANUAL TRANSFER SWITCH FOR
CONNECTION TO GENERATOR. COORDINATE CONNECTOR
TYPE WITH OWNER TO VERIFY GENERATOR COMPATIBILITY.
3. PROVIDE NEW FUSE COMPATIBLE WITH EXISTING
SWITCHBOARD.
4. PROVIDE SEPARATE SECTIONS FOR STANDARD AND
EMERGENCY BREAKERS WITHIN GDB.
5. EXISTING SWITCHGEAR SECTION MADE VACANT BY
DEMOLTION. MAKE SPLICES INDICATED WITH KEYNOTE 1 AT
THIS LOCATION. PROVIDE BLANK COVER COMPATIBLE WITH
EXISTING EQUIPMENT AS REQUIRED.
6. RELOCATE CONNECTION TO ADJACENT SW ITCHBOARD
SECTION AS REQUIRED TO VACATE ONE SWITCHBOARD
SECTION.
7. CONTRACTOR MAY UTILIZE EXISTING CONDUIT AND
CONDUCTORS FOR ROUTING FROM GENERATOR
ENCLOSURE TO GDB.
8. UTILIZE EXISTING PULL BOX LOCATED ADJACENT TO
EMERGENCY DISTRIBUTION PANEL FOR CONDUCTOR
SPLICES.
# KEYNOTES
GENERAL NOTES
A. COMPLY WITH LATEST ADOPTED NEC AND APPLICABLE
CODES/STANDARDS.
B. SHARED NEUTRALS ARE NOT ALLOWED FOR SINGLE PHASE
BRANCH CIRCUITS.
C. FIRE CAULK ALL NEW PENETRATIONS MADE TO FIRE RATED
WALLS TO MAINTAIN FIRE RATING.
D. SERVICE INTERRUPTIONS OF BUILDING ELECTRICAL
SYSTEMS SHALL ONLY OCCUR OUTSIDE OF REGULAR OFFICE
HOURS AND BE LIMITED TO 8 HOURS OUR LESS. ELECTRICAL
SERVICE SHUTDOWN SCHEDULE SHALL BE APPROVED BY
THE GOVERNMENT.
E. ELECTRICAL CONTRACTOR SHALL ADJUST PROGRAMMING
OF SCHNEIDER ELECTRIC PME POWER METERING DEVICES
AND SOFTWARE FOR ALL CHANGES TO THE POWER
METERING, USING MANUFACTURER AUTHORIZED SUPPORT,
AND PROVIDE A ONE YEAR SCHNEIDER ELECTRIC PME
POW ER METERING SERVICE CONTRACT FOR THE LOCAL
CAMPUS SERVER HOSTED PLATFORM UPON COMPLETION OF
THE PROJECT.
LINE TYPE LEGEND
EXISTING
NEW
DEMO
1 2 3 4 5
D
C
B
A
S h e e t T it le
D e s ig n e d b y
D ra w n b y
C h e c k e d b y
A p p ro v e d b y
R e v is io n s
U n it e d S ta te s D e p a rt m e n t o f th e
I n te ri o r
B u re a u o f L a n d M a n a g e m e n t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
/1
/2
:1
:1
P
M C
U s e rs
\t y le rv ic to ri n o \D o c u m e n ts
R e v it L o c a lT e m p \L
B Y
D B
L M
T
O e le c ty le rv ic to ri n o .r v t
N E
W W
O R
K O
N E
-L
IN
E D
IA
G
R A
M
V
IC
T O
R
IN
O
H E
S T
A N
D
V
IC
T O
R
IN
O
H E
S T
A N
D
N
IF
C
-J W
H S
T A
N D
B Y
A N
D E
M E
R G
E N
C Y
P O
W E
R
N
IF
C C
A M
P U
S
S
D E
V E
L O
P M
E N
T A
V E
B O
IS
E
ID
140L0619D0008
LBYDBLM24_TO21
11.15.2024
E-601
8 9
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
A1
NEW W ORK ONE-LINE DIAGRAM
D es cr ip tio n D at e
R ev is io n
3/
/2
14056
HADIFOET
AT
OSTY LER B. V ICTO
RI
RE
EN
IG
NELANOISSEFORP
| Sheets |
| E-101 - FIRST FLOOR POWER PLAN |
| E-600 - DEMOLITION ONE-LINE DIAGRAM |
| E-601 - NEW WORK ONE-LINE DIAGRAM |
File details come from the government source that posted it. Updated .