B09_Attachment_12_24_0820__USGS_A3_PHASE_II_100CD_DWGS_A101_Bid_Question_0003.pdf
PDF 915 KB Posted
- Attached to
- CERC Phase 2 A3 Bldg Stabilization
- Solicitation number
- 140G0124R0022
About this file
This document appears to be an attachment to a federal contract opportunity for the stabilization of the A3 main building at the U.S. Geological Survey's Columbia Environmental Research Center (CERC).
The key details are as follows: The scope of work includes adding helical piles to shore up the foundation, repairing and replacing portions of the concrete slab, walls, walks, and landscaping affected by the foundation work. The magnitude of construction is estimated to be between $250,000 and $500,000. The solicitation number is 140G0124R0022, and it will be issued around 7/22/2024 with proposals due around 8/21/2024. This is a total small business set-aside with the NAICS code 238190. A site visit is strongly encouraged. Bonds are required, and all responsible sources may submit a proposal.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HGFEDC J KD1C5B8B3BA
E1 E9
4.5
4.7
B2 B9 H1 H7D2 D9
6.5
AA2
5.6
0"
DN
6' - 7" 19' - 7" 7' - 0" 6" 10' - 2"
2' - 2" 5"
7' - 6" 8' - 4"
1' - 10" 1' - 7"
11' - 6" 11"
1' - 8"
12' - 6" 1' - 8" 15' - 10" 15' - 10" 5" 12' - 10" 6' - 6" 20' - 1"
5'
4'
9'
3'
6'
/4
9'
9'
4" DIA. PIPE COLUMN
4" DIA. PIPE COLUMN
DN
MECH.
ELEV.
RECEPTION
MAIN
ENTRANCE
TWO SIDED ELEVATOR OPENS TO OUTSIDE
WET LABORATORY
MAIN LOBBY PUBLIC STAIR TO
BASEMENT. SEE STRUCT
DWGS AND BASEMENT PLAN
FOR WORK IN BASEMENT.
UNDERPINNING SEE
STRUCTURAL DWGS. REPAINT
EXPOSED FOUNDATION WALLS
THROUGHOUT.
DEDUCTIVE BID
OPTION 1
SITE
LANDSCAPING
RESTORATION
165' - 5"
VERIFY IN FIELD
AREA OF
MICROPILES
SITE
LANDSCAPING
RESTORATION
SITE
LANDSCAPING
RESTORATION
VERIFY IN FIELD AREA OF
MICROPILES
VERIFY IN FIELD AREA OF
MICROPILES
V
IF
V
IF
RM 11
SEE PHOTO IN PLAN LEGEND: COLUMN ROOM 11
FOR EXISTING CMU CRACKING AND
DISPLACEMENT ABOVE DOOR AT COLUMN.
PARTIALLY DISASSEMBLE EXISTING CMU WALL AT
DAMAGED AREA. PATCH TO MATCH EXISTING.
REPLACE WITH NEW CMU GROUTED INTO
EXISTING WALL AND TO MATCH EXISTING. TOOL
ALL MORTAR JOINTS TO MATCH EXISTING. PREP
AND PROVIDE BLOCK FILLER PRIMER AND PAINT
WITH TWO COATS OF LATEX PAINT COLOR TO
MATCH EXISTING.
REMOVAL AND REPLACEMENT OF EXISTING
SLAB TO CONTROL JOINT AT MAIN ENTRANCE
FOR HELICAL PIER INSTALLATION. COORDINATE
W/ ARCH FOR AREA. REBUILD TO ASSURE THAT
ACCESSIBILITY IS MAINTAINED SO THAT NO
VERTICAL RISE OR DROP OF WALK AT ENTRY
DOOR. SEE CIVIL AND STRUCT. DWGS.
31.01
31.01
31.01
UNDERPINNING SEE
STRUCTURAL DWGS.
REPAINT EXPOSED
FOUNDATION WALLS
THROUGHOUT.
UNDERPINNING SEE STRUCTURAL
DWGS. REPAINT EXPOSED
FOUNDATION WALLS THROUGHOUT.
REMOVE AND REPLACE CONCRETE
PATIO SOUTH OF PERGOLA AS
NEEDED. DO NOT DAMAGE OR DEMO
EXISTING WOOD PERGOLA. DO NOT
DAMAGE OR DEMO CONCRETE BASE
AT PERGOLA POST, VIF.
EXISTING PERGOLA AND
CONCRETE PATIO BASE AT
ENTRANCE AND UNDER
PERGOLA TO REMAIN.
REMOVAL AND REPLACEMENT OF
SIDEWALK TO CONTROL JOINT AT
WEST ENTRANCE FOR HELICAL
PIER INSTALLATION. COORDINATE
W/ ARCH FOR AREA. REBUILD TO
ASSURE THAT ACCESSIBILITY IS
MAINTAINED SO THAT NO VERTICAL
RISE OR DROP OF WALK AT ENTRY
DOOR. SEE STRUCT. DWGS. FOR
DETAIL.
CONFIRM TREES IN AREA CAN BE
PROPERLY PROTECTED DURING
CONSTRUCTION.
NEW SIDEWALK WORK, SEE
CIVIL DWGS.
NEW SIDEWALK WORK, SEE
CIVIL DWGS.
NEW SIDEWALK WORK, SEE
CIVIL DWGS.
A101
SCAN FOR UTILITIES
PRIOR TO WORK AND
HAND DIG THROUGHOUT
THIS AREA.
01.00
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME TO REMAIN
AREA NOT IN SCOPE OF WORK
AREA OF WORK
CONCRETE: SIDEWALK / PATIO /
ENTRY, VIF WIDTH AND LENGTH.
NEW HELICAL PIERS UNDER
FOUNDATION WALL FOOTING, SEE
STRUCT. DWGS.
1. PROTECT THE EXISTING EXTERIOR WALL FROM DAMAGE THROUGHOUT THE WORK. PROVIDE
TEMPORARY PROTECTIONS TO EXISTING MASONRY WALLS, WIDOWS. GLASS UNITS, PROJECTING
ELEMENTS, ETC. AS REQUIRED.
2. GRASS IN CONSTRUCTION AREA TO BE RESEEDED WITH KENTUCKY #31 TALL FESCUE OR
SIMILAR MIX.
A. SOW SEED AT A RATE OF 3 TO 4 LB/1000 SQ. FT. RAKE SEED LIGHTLY AND
COVER WITH A THIN LAYER OF PLANTING SOIL TO SHIELD SEEDS FROM DETECTION BY
PESTS. ROLL LIGHTLY AND WATER WITH FINE SPRAY. WITHIN 24 HOURS, SOAK
SEEDED AREAS THEN PROTECT FROM HOT, DRY WEATHER OR DRYING WINDS BY
APPLYING 1/4” THICK LAYER OF MECHANICALLY-SECURED STRAW OR COMPOST
MULCH THROUGHOUT.
3. ALL TESTING AND INSPECTION SERVICES SHALL BE PROVIDED BY THE CONTRACTOR AT NO
COST TO THE GOVERNMENT. ALL COSTS ASSOCIATED WITH RETESTING AND RE INSPECTIONS
SHALL BE AT THE SOLE COST OF THE CONTRACTOR. REFERENCE SPECIFICATIONS SECTIONS 01
01 00 – GENERAL REQUIREMENTS AND 01 40 00 - QUALITY REQUIREMENTS.
GROUND FLOOR
0"
ROOF
10' - 0"
1 2 3
6' - 0"
5/ 8"
10"4'
V
IF
PROTECT CANOPY AND BRICK
FACADE THROUGHOUT
CONSTRUCTION
4'
/4
8" 8' - 10" VIF
4" 4'
8"
2"1' - 0"
EXISTING FOUNDATION WALL AND
FOOTING TO BE REINFORCED W/
STRUCTURE HELICAL PIERS, SEE
STRUCT. DWGS.
REMOVE AND SALVAGE
EXISTING STORE FRONT DOOR
FOR REINSTALLATION
REMOVE AND REPLACE EXISTING
CONCRETE ENTRY SLAB UP TO
INTERIOR, SEE CIVIL & STRUCT.
DWGS FOR ALL SLOPES AND
ADDITIONAL INFORMATION.
11' - 4" VIF
A101
GROUND FLOOR
0"
EXISTING FOUNDATION WALL
AND FOOTING TO REMAIN.
REMOVE AND SALVAGE EXISTING
STORE FRONT DOOR FOR
REINSTALLATION IN THE SAME
LOCATION PROVIDE NEW SS ANCHORS
AS REQ'D AND NEW CONTINUOUS
SILCONE SEALANT AND BACKER ROD
PERIMETER OF FRAME.
EXISTING SLAB AND VAPOR
BARRIER AT INTERIOR TO REMAIN.
NEW REINFORCED CONCRETE SLAB
AT ENTRANCE, SEE CIVIL & STRUCT.
DWGS.
EXISTING GRAVEL BASE TO REMIAN
ADD NEW COMPACT GRAVEL AND
SOIL AS NEEDED, SEE CIVIL &
STRUCT. DWGS.
NEW CONSTRUCTION JOINT
FILLER AND CONTINUOUS BACKER
ROD AND HORIZONTAL SEALANT.
EXISTING 1/2" PERIMETER
INSULATION TO REMAIN.10"
RESET EXISTING THRESHOLD W/
NEW SS ANCHORS IN NEW BED OF
SEALANT
PROTECT EXISTING WALLS AND
FINISHES
SLOPE
BE Project No.
Drawn By:
Drawing No.
Drawing Title t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
©2018 Bailey Edward Design Design Firm License No. 184-001962
Structural Engineer IMEG Corp.
15 Sunnen Dr. Suite 104 St. Louis, MO 63143 314-645-1132
SHEET
GROUND FLOOR
PLAN
A101
USGS OAG A3 MAIN
BUILDING STABILIZATION
PHASE II
18018
KH
Columbia Environmental Research Center (CERC) 4200 E New Haven Rd.
Columbia, MO 65201
1/8" = 1'-0"
GROUND FLOOR PLAN
0 4' 8' 16'
COLUMN ROOM 11
NEW WORK PLAN LEGEND
NEW WORK - GENERAL NOTES
KEYNOTES - NEW WORK
01.00 PRIOR TO COMMENSING WORK ONSITE, GROUND PENETRATING RADAR SURVEY SHALL BE
PERFORMED BY THE CONTRACTOR AT THE PERIMETER OF THE BUILDING IN ALL WORK AREAS
PRIOR TO THE START OF FOUNDATION REINFORCING. CONTACT THE OWNER IF ANY UTILITIES ARE
FOUND THAT MIGHT BE IMPACTED BY MICROPILE STABILIZATION. MARK UTILITY LOCATIONS
ONSITE AND COORDINATE WITH STRUCTURAL MICROPILE LOCATIONS. REFERENCE
SPECIFICATIONS SECTION 01 10 00 SUMMARY.
31.01 MICROPILES UNDER FOOTING, SEE STRUCT. DWGS.
1/4" = 1'-0"
SECTION
1 1/2" = 1'-0"
SECTION DETAIL
REVISION
MARK DESCRIPTION DATE
1 100% CD 05/17/2024
mpetti Callout 01.00 mpetti Cloud mpetti Callout 01.00 mpetti Cloud mpetti Text Box 2 BId Question Response 8/20/24 mpetti Text Box mpetti Text Box