140G0122Q0064_Attachment_03_Bldg_810_Blueprint_0002.pdf
PDF 23 MB Posted
- Solicitation number
- 140G0122Q0064
About this file
This document provides details for a federal contract opportunity to provide audio visual equipment for the Denver Learning Center. Solicitation number 140G0122Q0064 seeks to procure audio visual equipment for the Department of the Interior US Geological Survey Office of Acquisitions and Grants. Specifically, the opportunity involves providing audio visual equipment for the Denver Learning Center, with no information provided on pricing terms, response dates, or other contract details. An attachment to the solicitation includes blueprints for building 810, but offers no other salient information on the products or services required to fulfill this federal contract opportunity.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140G0122Q0064_Amd_0003.pdf | ||
| Solicitation_No_140G0122Q0064_Q_A__0003.xlsx | XLSX spreadsheet | |
| Solicitation_No_140G0122Q0064_Q_A__0002.xlsx | XLSX spreadsheet | |
| Sol_140G0122Q0064_Amd_0002.pdf | ||
| Sol_140G0122Q0064_Amd_0001.pdf | ||
| Solicitation_No__140G0122Q0064.pdf | ||
| Sol_140G0122Q0064.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
UP
N29b
UP
UP
UP
UP
U P
U P
TE
N A N T
TR
A
IL
E R
U S E D
A S
O F F
IC
E
USGS/DOI TRAINING CENTER - BUILDING 810
DRAWING SYMBOLS GENERAL NOTES CODE STATEMENT PARTICIPANTS
GRAPHIC SYMBOLS ABBREVIATIONS VICINITY MAP
DRAWING INDEX
NOT TO SCALE
CONTINUOUS LINE INDICATES
EXISTING WALL PARTITION
OVERHEAD LINES (ROOF, ETC.)
NEW METAL STUD PARTITION
ONE HOUR RATED WALL CONSTRUCTION
TWO HOUR RATED WALL CONSTRUCTION
EARTH
CONCRETE
GRAVEL
METAL STUD
WOOD FRAMING
WOOD BLOCKING
BATT
INSULATION
RIGID
INSULATION
SYNTHETIC
STONE
STEEL
CMU
GYPSUM
BOARD
1. ALL DIMENSIONS ARE FROM THE ROUGH FRAME SURFACE OF NEW STUD WALLS AND FACE OF
EXISTING, CMU OR CONCRETE WALLS UNLESS OTHERWISE NOTED.
2. CONTRACTOR SHALL PROVIDE ADEQUATE BLOCKING IN WALLS TO RECEIVE ALL ATTACHED
EQUIPMENT, PLUMBING FIXTURES, MILLWORK, CASEWORK, ETC.
3. PRIOR TO ACCEPTANCE OF THIS WORK, THE CONTRACTOR SHALL VISIT THE SITE AND BE FAMILIAR WITH THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. THE CONTRACTOR SHALL
REVIEW, APPROVE AND SUBMIT TO THE ARCHITECT SAMPLES, PRODUCT DATA, AND SHOP
DRAWINGS PRIOR TO INSTALLATION. BY DOING SO, THE CONTRACTOR REPRESENTS THAT HE HAS
VERIFIED FIELD CONDITIONS AND MEASUREMENTS.
4. CONTRACTOR TO NOTIFY ARCHITECT OF ANY CONFLICTS OR OMISSIONS IMMEDIATELY PRIOR TO
THE PERFORMANCE OF THE WORK IN QUESTION.
5. WHEN CONTRACTOR ACCEPTS DELIVERY OF ALL ITEMS NOTED ON PLANS, WHETHER IN CONTRACT OR NOT IN CONTRACT, HE SHALL BE RESPONSIBLE FOR LOSS AND/OR DAMAGE OF THESE ITEMS.
6. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN ALL PARTITION LOCATIONS. ALL DOOR AND OPENING LOCATIONS SHALL BE INDICATED ON PLAN. IN CASE OF CONFLICT, NOTIFY THE
ARCHITECT. ALL DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW FOR
THICKNESS OF ALL FINISHES INCLUDING CARPET, PAD, TILE, SHEET VINYL, WAINSCOT, ETC.
7. CONTRACTOR SHALL MARK LOCATIONS OF PARTITIONS AND DOORS FOR REVIEW BY THE OWNER
PRIOR TO INSTALLATION. REVIEW WILL BE FOR DESIGN INTENT. SYBCONTRACTOR SHALL
COORDINATE AND VERIFY ALL CONDITIONS TO ENSURE PROPER FIT.
8. COLUMN CENTER LINES ARE SHOWN FOR DIMENSIONING. VERIFY EXACT LOCATIONS IN FIELD.
9. ITEMS INDICATED IN THIS SET OF DOCUMENTS BY TENANT/OWNER ARE NOT A PART OF THIS CONTRACT, AND ARE TO BE FURNISHED AND INSTALLED BY TENANT UNLESS NOTED OTHERWISE.
10. ITEMS INDICATED IN THIS SET OF DOCUMENTS ARE NOT TO BE ALTERED WITHOUT WRITTEN
CONSENT FROM THE ARCHITECT OR ENGINEER. IF ALTERATIONS ARE MADE BY THE OWNER OR
CONTRACTOR, THE ARCHITECT AND/OR ENGINEER ASSUME NO RESPONSIBILITY FOR SUCH
CHANGES.
11. GSA REGIONAL FIRE PROTECTION ENGINEER IS THE DESIGNATED AUTHORITY HAVING
JURISDICTION (AHJ) PER P-100.
12. ALL DOORS AND HARDWARE SHALL MEET THE REQUIREMENTS OF NFPA 101 LIFE SAFETY CODE, CURRENT EDITION, AND THE GSA PBS BUILDING FACILITY STANDARDS. THE SPACE DESIGN SHALL
ADDITIONALLY MEET ALL NFPA 101 EGRESS AND EXIT ILLUMINATION REQUIREMENTS.
KEY PLAN
NOT TO SCALE
GOVERNING CODES
2018 INTERNATIONAL BUILDING CODE (IBC)
2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC)
2018 INTERNATIONAL MECHANICAL CODE (IMC)
2020 NATIONAL ELECTRICAL CODE (NEC)
2018 INTERNATIONAL PLUMBING CODE (IPC)
2018 INTERNATIONAL FUEL GAS CODE (IFGC)
2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2021 LIFE SAFETY CODE (NFPA 101)
2018 PBS-P-100
2019 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS (NFPA 13)
2019 NATIONAL FIRE ALARM AND SIGNALING CODE (NFPA 72)
ARCHITECTURAL BARRIERS AND ACCESSIBILITY STANDARD (ABAAS)
PROJECT DESCRIPTION
PROJECT IS THE REMODEL OF EXISTING TENANT SPACE WITHIN THE BUILDING. PROJECT INCLUDES THE
CONSTRUCTION OF TWO NEW LARGE AREA TRAINING ROOMS AND ASSEMBLY SPACE.
CODE DATA
OCCUPANCY CLASSIFICATION: B (BUSINESS), A-3 (LECTURE HALLS)
CONSTRUCTION TYPE: TYPE II-B, SPRINKLERED
GROSS BUILDING SQUARE FOOTAGE: 682,481 GROSS SQUARE FEET
SQUARE FOOTAGE AT AREAS OF WORK:
AREA 1: 4,785 GROSS SQUARE FEET
AREA 2: 7,264 GROSS SQUARE FEET
TRAINING ROOM 1A: 1,419 NET SQUARE FEET
TRAINING ROOM 1B: 1,315 NET SQUARE FEET
TRAINING ROOM 2: 1,289 NET SQUARE FEET
BREAKOUT ROOM 1: 221 NET SQUARE FEET
BREAKOUT ROOM 2: 263 NET SQUARE FEET
BREAKOUT ROOM 3: 277 NET SQUARE FEET
AREA 3: 6,852 GROSS SQUARE FEET
AREA 4: 557 NET SQUARE FEET
OCCUPANCY SEPARATION (TABLE 508.4): 1 HOUR BETWEEN B & A OCCUPANCIES
OCCUPANT LOAD
OCCUPANT LOAD FACTOR (TABLE 7.3.1.2)
BUSINESS AREAS 150 GSF PER PERSON
ASSEMBLY, TABLES & CHAIRS 15 NSF PER PERSON
TYPE II-B CONSTRUCTION, SPRINKLERED
LOCATION CALCULATION OCCUPANT LOAD
AREA 1:
BUSINESS AREAS: 4,600 GSF / 150 = 31 PERSONS
ASSEMBLY AREAS: 173 NSF / 15 = 12 PERSONS
AREA 1 TOTAL OCCUPANT LOAD: 43 PERSONS
AREA 2:
TRAINING ROOM 1A: 1,419 NSF / 15 = 95 PERSONS
TRAINING ROOM 1B: 1,315 NSF / 15 = 88 PERSONS
TRAINING ROOM 2: 1,289 NSF / 15 = 86 PERSONS
IT OFFICE: 466 GSF / 150 = 4 PERSONS
BREAKOUT ROOM 1: 221 NSF / 15 = 15 PERSONS
BREAKOUT ROOM 2: 263 NSF / 15 = 18 PERSONS
BREAKOUT ROOM 3: 277 NSF / 15 = 18 PERSONS
AREA 2 TOTAL OCCUPANT LOAD: 324 PERSONS
AREA 3:
BUSINESS AREAS: 6,852 GSF / 150 = 46 PERSONS
AREA 4:
ASSEMBLY AREAS: 557 / 15 = 38 PERSONS
TOTAL OCCUPANT LOAD AT AREAS OF WORK: 451 PERSONS
EXISTING OCCUPANT LOAD BASED ON 100 OCCUPANTS / SQUARE FOOT 2012 IBC LOAD FACTOR.
AREA 1:
BUSINESS AREAS 4,210 GSF / 100 = 43 PERSONS
AREA 2:
BUSINESS AREAS: 6,648 GSF / 100 = 67 PERSONS
ASSEMBLY AREAS: 616 NSF / 15 = 42 PERSONS
AREA 3:
BUSINESS AREAS: 6,852 GSF / 100 = 69 PERSONS
AREA 4:
BUSINESS AREAS: 614 GSF / 100 = 7 PERSONS
EXISTING OCCUPANT LOAD IN AREA OF WORK: 228 PERSONS
**INCREASE IN OCCUPANT LOAD AS A RESULT OF THIS PROJECT: 223 PERSONS**
EXITING REQUIREMENTS
NUMBER OF EXITS
LOCATION REQUIRED PROVIDED
AREA 1: 1 1
AREA 2: 2 3
TRAINING ROOM 1A: 2 3
TRAINING ROOM 1B: 2 2
TRAINING ROOM 2: 2 2
BREAKOUT ROOM 1: 1 1
BREAKOUT ROOM 2: 1 1
BREAKOUT ROOM 3: 1 1
IT OFFICE: 1 1
AREA 3: 1 2
AREA 4: 1 2
EGRESS SIZING (TABLE 7.3.3.1)
STAIR WIDTH (INCHES) = OCCUPANT LOAD x 0.3 OTHER EGRESS WIDTH (INCHES) = OCCUPANT LOAD x 0.2
LOCATION CALCULATION REQUIRED PROVIDED
AREA 1: 43 x 0.2 = 8.6" 72"
43 x 0.3 = 12.9" 44"
AREA 2: 324 x 0.2 = 64.8" 120" TRAINING ROOM 1A: 95 x 0.2 = 19" 108" TRAINING ROOM 1B: 88 x 0.2 = 17.6" 108" TRAINING ROOM 2: 86 x 0.2 = 17.2" 72"
AREA 3: 46 x 0.2 = 9.2" 72"
AREA 4: 38 x 0.2 = 7.6" 72"
TOILET ROOM REQUIREMENTS
NOTE: REFER TO SHEET T3 FOR DETAILED BREAKDOWN OF SPACES, USES AND SQUARE FOOTAGES THROUGHOUT BUILDING.
FIXTURE LOAD FACTORS, BY USE (TABLE 2902.1) WATER CLOSETS LAVATORIES DRINKING FOUNTAINS
NO. CLASSIFICATION DESCRIPTION MALE FEMALE MALE FEMALE
1 ASSEMBLY AUDITORIUMS WITHOUT PERMANENT SEATING, LECTURE HALLS 1 / 125 1 / 65 1 / 200 1 / 200 1 / 500 2 BUSINESS SPACES FOR THE TRANSACTION OF BUSINESS 1 / 50 + 1 1 / 50 + 1 1 / 80 + 1 1 / 80 + 1 1 / 100
8 STORAGE WAREHOUSES 1 / 100 1 / 100 1 / 100 1 / 100 1 / 1000
TOILET FIXTURE CALCULATION BY USE
NO. OCCUPANT LOAD OCCUPANT LOAD / SEX (50%)
1 818 OCCUPANTS 409 MALE / 409 FEMALE
2 530 OCCUPANTS 265 MALE / 265 FEMALE
8 196 OCCUPANTS 98 MALE / 98 FEMALE
NO. FIXTURE OCCUPANTS CALCULATION FIXTURES REQUIRED EXISTING FIXTURES PROVIDED
1 MALE WATER CLOSET 409 409 / 125 = 3.27
2 MALE WATER CLOSET 265 265 / 50 + 1 = 6.30
8 MALE WATER CLOSET 98 98 / 100 = 0.98
TOTAL MALE WATER CLOSET: 10.55 => 11 FIXTURES 30 (13 URINALS + 17 WATER CLOSETS)
NO. FIXTURE OCCUPANTS CALCULATION FIXTURES REQUIRED EXISTING FIXTURES PROVIDED
1 FEMALE WATER CLOSET 409 409 / 65 = 6.29
2 FEMALE WATER CLOSET 265 265 / 50 + 1 = 5.30
8 FEMALE WATER CLOSET 98 98 / 100 = 0.98
TOTAL FEMALE WATER CLOSET: 12.57 => 13 FIXTURES 26
NO. FIXTURE OCCUPANTS CALCULATION FIXTURES REQUIRED EXISTING FIXTURES PROVIDED
1 MALE LAVATORY 409 409 / 200 = 2.05
2 MALE LAVATORY 265 265 / 80 + 1 = 4.31
8 MALE LAVATORY 98 98 / 100 = 0.98
TOTAL MALE LAVATORY: 7.34 => 8 FIXTURES 13
NO. FIXTURE OCCUPANTS CALCULATION FIXTURES REQUIRED EXISTING FIXTURES PROVIDED
1 FEMALE LAVATORY 409 409 / 200 = 2.05
2 FEMALE LAVATORY 265 265 / 80 + 1 = 4.31
8 FEMALE LAVATORY 98 98 / 100 = 0.98
TOTAL FEMALE LAVATORY: 7.34 => 8 FIXTURES 18
NO. FIXTURE OCCUPANTS CALCULATION FIXTURES REQUIRED EXISTING FIXTURES PROVIDED
1 DRINKING FOUNTAIN 818 818 / 500 = 1.64
2 DRINKING FOUNTAIN 530 530 / 100 = 5.30
8 DRINKING FOUNTAIN 196 196 / 1000 = 0.20
TOTAL DRINKING FOUNTAIN: 7.14 => 8 FIXTURES 6 COMBINATION BOTTLE FILLER / DRINKING FOUNTAINS
ACCESSIBILITY REQUIREMENTS
ALL AISLES MUST BE A MINIMUM OF 36" IN WIDTH (CLEAR) FOR COMPLIANCE WITH ARCHITECTURAL BARRIERS ACT ACCESSSIBILITY STANDARDS (ABAAS). ALL NEW SINKS (BREAK ROOM AND TOILET
ROOM) SHALL HAVE A MAXIMUM RIM HEIGHT OF 34" ABOVE FINISH FLOOR.
OWNER
General Service Administration Building 41, Denver Federal Center Lakewood, Colorado CONTACT: Austin Sholly
303-513-8683
FIRE PROTECTION ENGINEER
Terp Consulting 14241 E 4th Avenue, Suite 5-230 Aurora, Colorado CONTACT: Wayne Griswold
303-985-3300
MECHANICAL ENGINEER
Plant Engineering Consultants 320 W Fillmore Colorado Springs, Colorado CONTACT: Mitchell Plant
719-473-7077
ARCHITECT
Design Edge, P.C.
482 S Broadway Denver, Colorado CONTACT: Mike Rageth
303-260-7277
PLUMBING ENGINEER
Plant Engineering Consultants 320 W Fillmore Colorado Springs, Colorado CONTACT: Mitchell Plant
719-473-7077
ELECTRICAL ENGINEER
Plant Engineering Consultants 320 W Fillmore Colorado Springs, Colorado CONTACT: Mitchell Plant
719-473-7077
STRUCTURAL ENGINEER
Stan Neujahr, Consulting Structural Engineer 600 S Cherry Street, Suite 220 Denver, Colorado CONTACT: Stan Neujahr
303-349-9844
A101
MASTER
BATHROOM
A101
Name Elevation
N
ROOM NAME AND NUMBER
OPENING NUMBER
CONSTRUCTION NOTE
DETAIL REFERENCE NUMBER
SHEET NUMBER
SECTION/ELEVATION NUMBER
SHEET NUMBER
REVISION NOTE
LEVEL NAME
LEVEL ELEVATION
SPOT ELEVATION T.O. -------
100'-0"
STRUCTURAL GRID
FIRE EXTINGUISHER CABINET
FEC
22FRAME ELEVATION NUMBER
RE: A8 SERIES
NORTH
PROJECT LOCATION
BUILDING 810
DENVER FEDERAL CENTER
US HIGHWAY 6
DENVER FEDERAL
CENTER VISITOR ENTRANCE
KI
PL
IN
G
PA
RK
W
AY
DENVER FEDERAL CENTER
SOUTH ENTRANCE
SI
MM
S
ST
RE
ET
ALAMEDA PARKWAY
AREA 2
AREA 1
AREA 3
NORTH
AREA 4
SHEET TITLE
SHEET
REVISED:
CHECKED
DRAWN BY
DATE
PROJECT NO.
c COPYRIGHT 2021, DESIGN EDGE, P.C. ALL
RIGHTS RESERVED. ANY COPYING OR OTHER
REPRODUCTION OF THESE DRAWINGS WITHOUT
THE PRIOR WRITTEN AUTHORIZATION OF DESIGN
EDGE, P.C. CONSTITUTES A VIOLATION OF
COPYRIGHT LAW AND WILL BE SUBJECT TO
LEGAL ACTION.
482 S Broadway - Suite 100 Denver, Colorado 80209 Telephone: 303-260-7277 Fax: 303-260-7282
711 N Cascade Avenue Colorado Springs, Colorado 80903 Telephone: 719-667-1972
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice. Properly destroy or return documents when no longer needed.
U.S. General Services Administration
T1
COVER SHEET AND PROJECT
INFORMATION
20165
MDR
ACO
U
SG
S/ D
O I T
R
AI
N
IN
G C
EN
TE
R
BU
IL
D
IN
G
D
EN
VE
R F
ED
ER
AL
C
EN
TE
R D
EN
VE
R , C
O
LO
R
AD
O
2/26/2021
REV. SHEET NAME
PROJECT INFORMATION
T1 COVER SHEET AND PROJECT INFORMATION
T2 LIFE SAFETY PLAN
T3 OCCUPANCY PLAN
ARCHITECTURAL
D1.1 DEMOLITION PLANS AND NOTES
D2.1 DEMOLITION CEILING PLAN
A1.1 FLOOR PLAN - DIMENSIONAL
A1.2 FLOOR PLAN - ROOM NAMES AND NUMBERS
A2.1 REFLECTED CEILING PLAN
A4.1 INTERIOR ELEVATIONS
A5.1 WALL SECTIONS
A6.1 DETAILS
A8.1 SCHEDULES
MECHANICAL
M001 MECHANICAL SYMBOL LEGEND
MD111 MECHANICAL HVAC DEMOLITION PLAN OVERALL
MD401 MECHANICAL DEMO ENLARGED PLAN - SOUTH
MD402 MECHANICAL DEMO ENLARGED PLAN - CENTRAL
MD403 MECHANICAL DEMO ENLARGED PLAN - NORTH
M111 MECHANICAL HVAC PLAN OVERALL
M401 MECHANICAL ENLARGED PLAN - SOUTH
M402 MECHANICAL ENLARGED PLAN - CENTRAL
M403 MECHANICAL ENLARGED PLAN - NORTH
M411 MECHANICAL ENLARGED FLOOR PLAN - SOUTH
M500 MECHANICAL DETAILS AND SCHEDULES
M601 MECHANICAL HVAC SCHEMATICS
M602 MECHANICAL HVAC SCHEMATICS
PLUMBING
P001 PLUMBING SYMBOL LEGEND
PD111 PLUMBING DEMO PLAN
P111 PLUMBING PLAN OVERALL
P401 PLUMBING ENLARGED WATER PLAN- SOUTH
P402 PLUMBING ENLARGED SANITARY PLAN- SOUTH
P403 PLUMBING ENLARGED PLAN- NORTH
P500 PLUMBING DETAILS AND SCHEDULES
FIRE SPRINKLER
FP-101 NEW FIRE SPRINKLER LOCATIONS
FP-102 EXISTING FIRE SPINKLER LOCATIONS
FIRE ALARM
FA-101 NEW FIRE ALARM PLANS
FA-102 FIRE ALARM DEMO FLOOR PLAN
ELECTRICAL
E001 ELECTRICAL SYMBOL LEGEND
ED111 ELECTRICAL LIGHTING DEMOLITION PLAN OVERALL
ED121 ELECTRICAL POWER AND SIGNAL DEMOLITION PLAN OVERALL
E111 ELECTRICAL LIGHTING PLAN OVERALL
E121 ELECTRICAL POWER AND SIGNALPLAN OVERALL
E600 ELECTRICAL ONE LINE DIAGRAM
E610 ELECTRICAL SCHEDULES
E611 ELECTRICAL SCHEDULES
LAM LAMINATE
MAX MAXIMUM
MIN MINIMUM
MO MASONRY OPENING
NIC NOT IN CONTRACT
NO NUMBER
NTS NOT TO SCALE
OC ON CENTER
OD OVERFLOW DRAIN
+/- PLUS OR MINUS
P.J PRECAST PANEL JOINT
RAD RADIUS
RB RUBBER BASE
RD ROOF DRAIN
RE: REFER TO
R.O. ROUGH OPENING
SIM SIMILAR
SPEC SPECIFICATIONS
T.O. TOP OF
TS TUBE STEEL
TYP. TYPICAL
VB VINYL BASE
VCT VINYL COMPOSITION TILE
WD WOOD
ACT ACOUSTICAL CEILING TILE
AFF ABOVE FINISH FLOOR
ALUM ALUMINUM
ANOD ANODIZED
< ANGLE
B.O. BOTTOM OF
CJ CONTROL JOINT
CMU CONCRETE MASONRY UNIT
CT CERAMIC TILE
- CENTER LINE
DIA DIAMETER
DS DOWNSPOUT
(E) EXISTING
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EJ EXPANSION JOINT
ELEV ELEVATION
EQ EQUAL
EWC ELECTRIC WATER COOLER
FD FLOOR DRAIN
FE FIRE EXTINGUISHER CABINET
FRT FIRE RETARDANT TREATED
FV FIELD VERIFY
GA GAUGE
GC GENERAL CONTRACTOR
HM HOLLOW METAL
CL
35% Review 11/04/2020 65% Review 1/15/2021 95% Review 2/26/2021 Construction Docs 4/2/2021
REF
65"
65"
86"
86"
70" 70"
86"
86"
86"
86"
60" 60"
AREA 1:
BUSINESS OCCUPANCY - 1:150 GSF
4,600 GROSS SQUARE FEET
150 GROSS SF / OCCUPANT
4,600 / 150 = 31 OCCUPANTS
ASSEMBLY OCCUPANCY - 1:15 NSF
173 NET SQUARE FEET
15 NET SF / OCCUPANT
173 / 15 = 12 OCCUPANTS
TOTAL LOAD: 43 OCCUPANTS
160 OCCUPANTS
22 OCC
AREA 3:
BUSINESS OCCUPANCY
7,438 GROSS SQUARE FEET
150 GROSS SF / OCCUPANT
7,438 / 150 = 50 OCCUPANTS
160 OCCUPANTS
O
CC
O
CC
0'
PA
TH
O
F
TR
AV
EL
TRAINING ROOM 2
1289 NET SQUARE FEET
15 NET SF / OCCUPANT
1,289 / 15 = 86 OCCUPANTS
CONFERENCE ROOM
263 NET SQUARE FEET
15 NET SF / OCCUPANT
263 / 15 = 18 OCCUPANTS
TRAINING ROOM 1A
1,419 NET SQUARE FEET
15 NET SF / OCCUPANT
1,419 / 15 = 95 OCCUPANTS
TRAINING ROOM 1B
1,315 NET SQUARE FEET
15 NET SF / OCCUPANT
1,315 / 15 = 88 OCCUPANTS
TRAINING ROOM 1
2,829 NET SQUARE FEET
15 NET SF / OCCUPANT
2,829 / 15 = 189 OCCUPANTS
CONFERENCE ROOM
277 NET SQUARE FEET
15 NET SF / OCCUPANT
277 / 15 = 18 OCCUPANTS 19
'-1 1'
DE
AD
E
ND
4 O
CC
OFFICE
466 GROSS SQUARE FEET
150 GROSS SF / OCCUPANT
466 / 150 = 4 OCCUPANTS
76.5' PATH OF TRAVEL
CONFERENCE ROOM
221 NET SQUARE FEET
15 NET SF / OCCUPANT
221 / 15 = 15 OCCUPANTS
21 OCC
AREA 4:
ASSEMBLY OCCUPANCY
557 NET SQUARE FEET
15 NET SF / OCCUPANT
557 / 15 = 38 OCCUPANTS
GENERAL NOTES
1. MEANS OF EGRESS SHALL COMPLY WITH THE REQUIREMENTS OF
GSA P-100 2018 EDITION AND NFPA 101 2021 EDITION, CHAPTER 7.
2. PER NFPA 101 TABLE A.7.6, MAXIMUM COMMON PATH OF TRAVEL
DISTANCE IS 75' FOR ASSEMBLY AND 100' FOR BUSINESS
OCCUPANCIES. THERE ARE NO COMMON PATHS SERVING
GREATER THAN 50 PERSONS.
3. PER NFPA 101 TABLE A.7.6 MAXIMUM EXIT ACCESS TRAVEL
DISTANCE IS 250' FOR ASSEMBLY AND 300' FOR BUSINESS
OCCUPANCIES.
4. PER NFPA 101 TABLE A.7.6, MAXIMUM DEAD END LENGTH IS 20' FOR
ASSEMBLY AND 50' FOR BUSINESS OCCUPANCIES.
5. INDICATES TENANT AREAS NOT IN SCOPE OF WORK.
SHEET TITLE
SHEET
REVISED:
CHECKED
DRAWN BY
DATE
PROJECT NO.
c COPYRIGHT 2021, DESIGN EDGE, P.C. ALL
RIGHTS RESERVED. ANY COPYING OR OTHER
REPRODUCTION OF THESE DRAWINGS WITHOUT
THE PRIOR WRITTEN AUTHORIZATION OF DESIGN
EDGE, P.C. CONSTITUTES A VIOLATION OF
COPYRIGHT LAW AND WILL BE SUBJECT TO
LEGAL ACTION.
TRUE NORTH
482 S Broadway - Suite 100 Denver, Colorado 80209 Telephone: 303-260-7277 Fax: 303-260-7282
711 N Cascade Avenue Colorado Springs, Colorado 80903 Telephone: 719-667-1972
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice. Properly destroy or return documents when no longer needed.
U.S. General Services Administration
T2
LIFE SAFETY PLAN
20165
MDR
ACO
U
SG
S/ D
O I T
R
AI
N
IN
G C
EN
TE
R
BU
IL
D
IN
G
D
EN
VE
R F
ED
ER
AL
C
EN
TE
R D
EN
VE
R , C
O
LO
R
AD
O
2/26/2021
FIRE PROTECTION
ENGINEER APPROVAL
LEGEND
COMMON PATH OF EGRESS TRAVEL AND DIRECTION
EXIT SIGN (SHADED INDICATES ILLUMINATION SIDE
ARROW INDICATES DIRECTION REFERENCE
3/32" = 1'-0"
LIFE SAFETY PLAN
AT AREA OF WORK
35% Review 11/04/2020 65% Review 1/15/2021
UP
UP
UP
UP
UP
U P
U P
WAREHOUSE AREAS
MECHANICAL, ELECTRICAL AND DATA AREAS
OFFICE AREAS
ASSEMBLY AREAS
KITCHEN AREAS
TOILET ROOMS
AREA OF WORK
STORAGE AREAS
19,774 GROSS SQUARE FEET
24,824 GROSS SQUARE FEET
66,993 GROSS SQUARE FEET
6,725 NET SQUARE FEET
481 GROSS SQUARE FEET
REFER TO COVER SHEET FOR OCCUPANCY CALCULATIONS
22,088 GROSS SQUARE FEET
1 OCCUPANT / 500 GROSS SQUARE FEET
1 OCCUPANT / 300 GROSS SQUARE FEET
1 OCCUPANT / 150 GROSS SQUARE FEET
1 OCCUPANT / 15 NET SQUARE FEET
1 OCCUPANT / 200 GROSS SQUARE FEET
1 OCCUPANT / 300 GROSS SQUARE FEET
39.5 OCCUPANTS
82.7 OCCUPANTS
446.6 OCCUPANTS
448.3 OCCUPANTS
2.4 OCCUPANTS
73.6 OCCUPANTS
TYPE OF AREA SQUARE FOOTAGE TALLY OCCUPANT LOAD NUMBER OF OCCUPANTS
1,544 OCCUPANTS
451 OCCUPANTS
OCCUPANT LOAD CALCULATIONS
DOE SCIF SUITE ALL REQUIRED TOILET FIXTURES SERVING THIS AREA ARE WITHIN SCIF SUITE
810 WAREHOUSE SPACES
810 WAREHOUSE OFFICE SPACE
NOT COUNTED TOWARDS OCCUPANT LOAD
442,618 GROSS SQUARE FEET 1 OCCUPANT / 500 GROSS SQUARE FEET 886 OCCUPANTS
12,572 GROSS SQUARE FEET 84 OCCUPANTS1 OCCUPANT / 150 GROSS SQUARE FEET
TOILET ROOM REQUIREMENTS
NOTE: REFER TO SHEET T3 FOR DETAILED BREAKDOWN OF SPACES, USES AND SQUARE FOOTAGES THROUGHOUT BUILDING.
FIXTURE LOAD FACTORS, BY USE (TABLE 2902.1) WATER CLOSETS LAVATORIES DRINKING FOUNTAINS
NO. CLASSIFICATION DESCRIPTION MALE FEMALE MALE FEMALE
1 ASSEMBLY AUDITORIUMS WITHOUT PERMANENT SEATING, LECTURE HALLS 1 / 125 1 / 65 1 / 200 1 / 200 1 / 500 2 BUSINESS SPACES FOR THE TRANSACTION OF BUSINESS 1 / 50 + 1 1 / 50 + 1 1 / 80 + 1 1 / 80 + 1 1 / 100
8 STORAGE WAREHOUSES 1 / 100 1 / 100 1 / 100 1 / 100 1 / 1000
TOILET FIXTURE CALCULATION BY USE
NO. OCCUPANT LOAD OCCUPANT LOAD / SEX (50%)
1 818 OCCUPANTS 409 MALE / 409 FEMALE
2 530 OCCUPANTS 265 MALE / 265 FEMALE
8 196 OCCUPANTS 98 MALE / 98 FEMALE
NO. FIXTURE OCCUPANTS CALCULATION FIXTURES REQUIRED EXISTING FIXTURES PROVIDED
1 MALE WATER CLOSET 409 409 / 125 = 3.27
2 MALE WATER CLOSET 265 265 / 50 + 1 = 6.30
8 MALE WATER CLOSET 98 98 / 100 = 0.98
TOTAL MALE WATER CLOSET: 10.55 => 11 FIXTURES 30 (13 URINALS + 17 WATER CLOSETS)
NO. FIXTURE OCCUPANTS CALCULATION FIXTURES REQUIRED EXISTING FIXTURES PROVIDED
1 FEMALE WATER CLOSET 409 409 / 65 = 6.29
2 FEMALE WATER CLOSET 265 265 / 50 + 1 = 5.30
8 FEMALE WATER CLOSET 98 98 / 100 = 0.98
TOTAL FEMALE WATER CLOSET: 12.57 => 13 FIXTURES 26
NO. FIXTURE OCCUPANTS CALCULATION FIXTURES REQUIRED EXISTING FIXTURES PROVIDED
1 MALE LAVATORY 409 409 / 200 = 2.05
2 MALE LAVATORY 265 265 / 80 + 1 = 4.31
8 MALE LAVATORY 98 98 / 100 = 0.98
TOTAL MALE LAVATORY: 7.34 => 8 FIXTURES 13
NO. FIXTURE OCCUPANTS CALCULATION FIXTURES REQUIRED EXISTING FIXTURES PROVIDED
1 FEMALE LAVATORY 409 409 / 200 = 2.05
2 FEMALE LAVATORY 265 265 / 80 + 1 = 4.31
8 FEMALE LAVATORY 98 98 / 100 = 0.98
TOTAL FEMALE LAVATORY: 7.34 => 8 FIXTURES 18
NO. FIXTURE OCCUPANTS CALCULATION FIXTURES REQUIRED EXISTING FIXTURES PROVIDED
1 DRINKING FOUNTAIN 818 818 / 500 = 1.64
2 DRINKING FOUNTAIN 530 530 / 100 = 5.30
8 DRINKING FOUNTAIN 196 196 / 1000 = 0.20
TOTAL DRINKING FOUNTAIN: 7.14 => 8 FIXTURES 6 COMBINATION BOTTLE FILLER / DRINKING FOUNTAINS
TOILET ROOM REQUIREMENTS AT 810 WAREHOUSE SPACES
FIXTURE LOAD FACTORS, BY USE (TABLE 2902.1) WATER CLOSETS LAVATORIES DRINKING FOUNTAINS
NO. CLASSIFICATION DESCRIPTION MALE FEMALE MALE FEMALE
8 STORAGE WAREHOUSES 1 / 100 1 / 100 1 / 100 1 / 100 1 / 1000
TOILET FIXTURE CALCULATION BY USE
NO. OCCUPANT LOAD OCCUPANT LOAD / SEX (50%)
8 886 OCCUPANTS 443 MALE / 443 FEMALE
NO. FIXTURE OCCUPANTS CALCULATION FIXTURES REQUIRED EXISTING FIXTURES PROVIDED
8 MALE WATER CLOSET 443 443 / 100 = 4.43 9 (4 URINALS + 5 WATER CLOSETS)
8 FEMALE WATER CLOSET 443 443 / 100 = 4.43 6
8 MALE LAVATORY 443 443 / 100 = 4.43 6
8 FEMALE LAVATORY 443 443 / 100 = 4.43 5
8 DRINKING FOUNTAIN 443 443 / 1000 = 0.44 5
TOILET ROOM REQUIREMENTS AT 810 WAREHOUSE OFFICE SPACE
FIXTURE LOAD FACTORS, BY USE (TABLE 2902.1) WATER CLOSETS LAVATORIES DRINKING FOUNTAINS
NO. CLASSIFICATION DESCRIPTION MALE FEMALE MALE FEMALE
2 BUSINESS SPACES FOR THE TRANSACTION OF BUSINESS 1 / 25 1 / 25 1 / 40 1 / 40 1 / 100
TOILET FIXTURE CALCULATION BY USE
NO. OCCUPANT LOAD OCCUPANT LOAD / SEX (50%)
2 84 OCCUPANTS 42 MALE / 42 FEMALE
NO. FIXTURE OCCUPANTS CALCULATION FIXTURES REQUIRED EXISTING FIXTURES PROVIDED
2 MALE WATER CLOSET 42 42 / 25 = 1.68 (2) 4 (2 URINALS + 2 WATER CLOSETS)
2 FEMALE WATER CLOSET 42 42 / 25 = 1.68 (2) 4
2 MALE LAVATORY 42 42 / 40 = 1.05 (2) 2
2 FEMALE LAVATORY 42 42 / 40 = 1.05 (2) 2
2 DRINKING FOUNTAIN 42 42 / 100 = 0.42 (1) 0
NOTES:
1. A VISUAL ASSESSMENT OF SPACES WAS PERFORMED TO DETERMINE FUNCTION OF INDIVIDUAL SPACES THROUGHOUT BUILDING 810.
2. OCCUPANCY CALCULATIONS AND TOILET FIXTURE CALCULATIONS BASED OFF 2018 INTERNATIONAL BUILDING CODE.
3. OCCUPANT LOAD BY SEX IS DETERMINED TO BE DIVIDED BY 2 PER 2902.1.1
4. TOILET ROOMS AND CORRIDORS ARE CONSIDERED TO BE NON-CONTRIBUTING TO THE TOILET FIXTURE CALCULATIONS.
5. MULTIPLE TOILET ROOMS ARE EXISTING AND ARE IN COMPLIANCE WITH A 500 FOOT MAXIMUM TRAVEL DISTANCE (2902.3.3).
6. DRINKING FOUNTAINS ARE LOCATED NEAR EACH TOILET ROOM GROUPING AND ARE IN COMPLIANCE WITH A 500 FOOT MAXIMUM TRAVEL DISTANCE (2902.5)
SHEET TITLE
SHEET
REVISED:
CHECKED
DRAWN BY
DATE
PROJECT NO.
c COPYRIGHT 2021, DESIGN EDGE, P.C. ALL
RIGHTS RESERVED. ANY COPYING OR OTHER
REPRODUCTION OF THESE DRAWINGS WITHOUT
THE PRIOR WRITTEN AUTHORIZATION OF DESIGN
EDGE, P.C. CONSTITUTES A VIOLATION OF
COPYRIGHT LAW AND WILL BE SUBJECT TO
LEGAL ACTION.
TRUE NORTHPROJECT NORTH
482 S Broadway - Suite 100 Denver, Colorado 80209 Telephone: 303-260-7277 Fax: 303-260-7282
711 N Cascade Avenue Colorado Springs, Colorado 80903 Telephone: 719-667-1972
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice. Properly destroy or return documents when no longer needed.
U.S. General Services Administration
T3
OCCUPANCY PLAN
20165
MDR
ACO
U
SG
S/ D
O I T
R
AI
N
IN
G C
EN
TE
R
BU
IL
D
IN
G
D
EN
VE
R F
ED
ER
AL
C
EN
TE
R D
EN
VE
R , C
O
LO
R
AD
O
2/26/2021
GENERAL DEMOLITION PLAN NOTES
1. CONTRACTOR SHALL COMPLETE ALL INTERIOR DEMOLITION BASED ON THE DOCUMENTS ADJACENT FLOOR PLAN AND
SPECIFICATIONS.
2. CONTRACTOR SHALL THOROUGHLY REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM THE BUILDING. COORDINATE
DUMPSTER LOCATIONS WITH BUILDING OWNER.
3. REFER TO MECHANICAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL DRAWINGS FOR FULL EXTENT OF M, P, F, AND E
DEMOLITION.
4. DASHED LINES INDICATE EXTENT OF WALLS, DOORS, EQUIPEMENT, CEILINGS, LIGHT FIXTURES, AND PLUMBING FIXTURES
TO BE REMOVED.
5. CONTRACTOR SHALL THOROUGHLY CLEAN, MAKE ANY REPAIRS, AND MAKE FULLY FUNCTIONAL THE HVAC SYSTEM AND
ELECTRICAL SYSTEM AFFECTED BY THE WORK.
6. CONTRACTOR SHALL PROTECT ALL EXISTING CONDITIONS TO REMAIN DURING DEMOLITION AND CONSTRUCTION.
7. PROVIDE PROTECTIVE BARRIER TO PREVENT THE SPREAD OF DUST AND DEBRIS DURING DEMOLITION AND
CONSTRUCTION.
8. PREPARE EXISTING WALLS AND SUBFLOOR TO REMAIN FOR INSTALLATION OF NEW FINISHES.
9. CONTRACTOR SHALL STOP WORK AND NOTIFY OWNER IMMEDIATELY IF HAZARDOUS MATERIALS NOT IDENTIFIED IN THE
ASBESTOS REPORT ARE DISCOVERED ON SITE.
10. G.C. SHALL MAINTAIN THE INTEGRITY OF EXISTING FIRE SEPARATIONS AT WALLS AND FLOOR/CEILING ASSEMBLIES. G.C.
SHALL PROTECT EXISTING FIREPROOFING TO MAINTAIN REQUIRED FIRE RATING.
11. REMOVE EXISTING WALL COMPLETELY MEANS TO REMOVE ALL WALL FINISHES, SUBSTRATES, BLOCKING, FRAMING, ETC.
FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE.
NIC
NIC
NICNICNIC NIC
NIC
NIC
NIC
NIC
NIC
NIC NIC NIC
NICNIC
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NIC
NIC
1 1
2 2
1 1
4 4
6 6
8 8
1'-3 7/8"
5'-
2 2
NIC
1'-1" 3'-0" 1'-5 1/2" 3'-0" 5'-8"
SHEET TITLE
SHEET
REVISED:
CHECKED
DRAWN BY
DATE
PROJECT NO.
c COPYRIGHT 2021, DESIGN EDGE, P.C. ALL
RIGHTS RESERVED. ANY COPYING OR OTHER
REPRODUCTION OF THESE DRAWINGS WITHOUT
THE PRIOR WRITTEN AUTHORIZATION OF DESIGN
EDGE, P.C. CONSTITUTES A VIOLATION OF
COPYRIGHT LAW AND WILL BE SUBJECT TO
LEGAL ACTION.
TRUE NORTHPROJECT NORTH
482 S Broadway - Suite 100 Denver, Colorado 80209 Telephone: 303-260-7277 Fax: 303-260-7282
711 N Cascade Avenue Colorado Springs, Colorado 80903 Telephone: 719-667-1972
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice. Properly destroy or return documents when no longer needed.
U.S. General Services Administration
D1.1
DEMOLITION PLANS AND
NOTES
20165
MDR
ACO
U
SG
S/ D
O I T
R
AI
N
IN
G C
EN
TE
R
BU
IL
D
IN
G
D
EN
VE
R F
ED
ER
AL
C
EN
TE
R D
EN
VE
R , C
O
LO
R
AD
O
2/26/2021
KEYED NOTES
1 COMPLETELY DEMOLISH EXISTING WALL TO EXTENT INDICATED. PREPARE ADJACENT SURFACES FOR INSTALLATION OF
NEW FINISHES.
2 EXISTING WALL TO REMAIN. PATCH AND REPAIR TENANT SIDE AS REQUIRED TO INSTALL NEW FINISHES.
3 DEMOLISH EXISTING DOOR, FRAME AND HARDWARE COMPLETELY AND DISPOSE.
4 EXISTING DOOR, GLAZING, FRAME AND HARDWARE TO REMAIN. PROTECT DURING CONSTRUCTION.
5 EXISTING RAISED FLOORING THIS AREA TO REMAIN. REMOVE CARPET FINISH COMPLETELY AND PREPARE FOR
INSTALLATION OF NEW FINISHES.
6 EXISTING STRUCTURAL COLUMN AND WRAP TO REMAIN. PATCH AND REPAIR AS REQUIRED TO ALLOW FOR INSTALLATION OF
NEW FINISHES.
7 COMPLETELY REMOVE EXISTING SHELVING AND SUPPORTS. PREPARE ADJACENT SURFACES AS REQUIRED TO ALLOW FOR
INSTALLATION OF NEW FINISHES.
8 DEMOLISH WALL AS REQUIRED TO INSTALL NEW DOOR AND FRAME.
9 HATCH INDICATES REMOVE EXISTING FLOOR FINISH THIS ROOM COMPLETELY. REPAIR SUBFLOOR AS REQUIRED TO ALLOW
FOR SMOOTH, LEVEL FLOOR THROUGHOUT SPACE.
10 REMOVE EXISTING DOOR, GLAZING, FRAME AND HARDWARE COMPLETELY. SALVAGE FOR REUSE.
11 EXISTING ELECTRICAL EQUIPMENT THIS AREA TO REMAIN. REFER TO ELECTRICAL DRAWINGS FOR EXTENT OF WORK.
12 REMOVE EXISTING COLUMN WRAP AS INDICATED. PROTECT EXISTING STRUCTURAL COLUMN AND FIREPROOFING TO
REMAIN.
13 EXISTING MEZZANINE ACCESS AND MEZZANINE ABOVE TO REMAIN.
14 REPAIR EXISTING SUBFLOOR THIS AREA AS REQUIRED TO INSTALL NEW RAISED FLOOR SYSTEM.
15 REMOVE EXISTING MILLWORK THIS AREA COMPLETELY AND DISPOSE. REFER TO PLUMBING DRAWINGS FOR EXTENT OF
PLUMBING DEMOLITION AT SINK.
16 EXISTING MILLWORK TO REMAIN. PROTECT DURING CONSTRUCTION.
17 EXISTING PLUMBING CHASE ACCESS DOOR TO REMAIN. PROTECT DURING CONSTRUCTION.
18 EXISTING STOREFRONT OR WINDOW FRAME AND GLAZING TO REMAIN. PROTECT DURING CONSTRUCTION.
19 REMOVE EXISTING DOOR, FRAME AND HARDWARE COMPLETELY. SALVAGE EXISTING CARDREADER FOR REUSE.
1/8" = 1'-0"
DEMOLITION PLAN
AT AREA OF WORK
35% Review 11/04/2020 65% Review 1/15/2021
2 2
22 2
3 3
NIC
NIC
NIC
NIC NIC NIC
NIC
NIC
NIC
NIC
NIC
NIC NIC NIC
NIC NIC NIC
NIC NIC NIC
NIC
NIC
NIC
NIC
NIC
GENERAL DEMOLITION PLAN NOTES
1. CONTRACTOR SHALL COMPLETE ALL INTERIOR DEMOLITION BASED ON THE DOCUMENTS ADJACENT FLOOR PLAN AND
SPECIFICATIONS.
2. CONTRACTOR SHALL THOROUGHLY REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM THE BUILDING. COORDINATE
DUMPSTER LOCATIONS WITH BUILDING OWNER.
3. REFER TO MECHANICAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL DRAWINGS FOR FULL EXTENT OF M, P, F, AND E
DEMOLITION.
4. DASHED LINES INDICATE EXTENT OF WALLS, DOORS, EQUIPEMENT, CEILINGS, LIGHT FIXTURES, AND PLUMBING FIXTURES
TO BE REMOVED.
5. CONTRACTOR SHALL THOROUGHLY CLEAN, MAKE ANY REPAIRS, AND MAKE FULLY FUNCTIONAL THE HVAC SYSTEM AND
ELECTRICAL SYSTEM AFFECTED BY THE WORK.
6. CONTRACTOR SHALL PROTECT ALL EXISTING CONDITIONS TO REMAIN DURING DEMOLITION AND CONSTRUCTION.
7. PROVIDE PROTECTIVE BARRIER TO PREVENT THE SPREAD OF DUST AND DEBRIS DURING DEMOLITION AND
CONSTRUCTION.
8. PREPARE EXISTING WALLS AND SUBFLOOR TO REMAIN FOR INSTALLATION OF NEW FINISHES.
9. CONTRACTOR SHALL STOP WORK AND NOTIFY OWNER IMMEDIATELY IF HAZARDOUS MATERIALS NOT IDENTIFIED IN THE
ASBESTOS REPORT ARE DISCOVERED ON SITE.
10. G.C. SHALL MAINTAIN THE INTEGRITY OF EXISTING FIRE SEPARATIONS AT WALLS AND FLOOR/CEILING ASSEMBLIES. G.C.
SHALL PROTECT EXISTING FIREPROOFING TO MAINTAIN REQUIRED FIRE RATING.
11. REMOVE EXISTING WALL COMPLETELY MEANS TO REMOVE ALL WALL FINISHES, SUBSTRATES, BLOCKING, FRAMING, ETC.
FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE.
SHEET TITLE
SHEET
REVISED:
CHECKED
DRAWN BY
DATE
PROJECT NO.
c COPYRIGHT 2021, DESIGN EDGE, P.C. ALL
RIGHTS RESERVED. ANY COPYING OR OTHER
REPRODUCTION OF THESE DRAWINGS WITHOUT
THE PRIOR WRITTEN AUTHORIZATION OF DESIGN
EDGE, P.C. CONSTITUTES A VIOLATION OF
COPYRIGHT LAW AND WILL BE SUBJECT TO
LEGAL ACTION.
TRUE NORTHPROJECT NORTH
482 S Broadway - Suite 100 Denver, Colorado 80209 Telephone: 303-260-7277 Fax: 303-260-7282
711 N Cascade Avenue Colorado Springs, Colorado 80903 Telephone: 719-667-1972
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice. Properly destroy or return documents when no longer needed.
U.S. General Services Administration
D2.1
DEMOLITION CEILING PLAN
20165
MDR
ACO
U
SG
S/ D
O I T
R
AI
N
IN
G C
EN
TE
R
BU
IL
D
IN
G
D
EN
VE
R F
ED
ER
AL
C
EN
TE
R D
EN
VE
R , C
O
LO
R
AD
O
2/26/2021
1/8" = 1'-0"
DEMOLITION PLAN
AT CEILING
KEYED NOTES
1 EXISTING CEILING CONSTRUCTION TO REMAIN.
2 REMOVE EXISTING CEILING TILES, GRID AND SUSPENSION SYSTEM COMPLETELY.
3 REMOVE EXISTING GYPSUM BOARD CEILING THIS AREA. REMOVE SOFFIT DROP WALLS COMPLETELY FROM TOP OF CEILING
TO UNDERSIDE STRUCTURE ABOVE.
4 EXISTING CLERESTORY WINDOWS TO REMAIN. PROTECT DURING CONSTRUCTION.
5 REMOVE EXISTING CLERESTORY WINDOW COMPLETELY. SALVAGE FOR REUSE.
DN
8' x 10'
8' x 10' 8' x 10'
8' x 10'8' x 10'
8' x 10' 8' x 10'
8' x 10'
8' x 10'
8' x 10'
8' x 10'
8' x 10'
8' x 10'
8' x 10'
CopierCopier Copier
48'-8 1/2"
'-0
'-1 1/
2"
'-1
1"
'-5
7'- 5 1
/2"
'-3 1/
2"
'-0
'-6
'-4 1/
2" 5'-
0"
40'-8 1/2" 10'-0 1/2" 5'-6" 9'-2 1/2" 4'-0 1/2"
16'-11 1/2" 12'-1" 11'-8" 2'-0" 8'-0 1/2"
'-5
1/ 2"
'-6
1/ 2"
'-4
6'-
5 1 /2"
'-5
1/ 2"
4'- 5"
'-9
4'- 4"
'-3
3'-
9"
7'-3 1/2" 6'-0" 5'-0"2'-6" 19'-1 1/2" 10'-10" 7'-5" 7'-3 1/2"
8' x 10'
Sh re d Bi n
DN
1"
/ 1 2"
8'-9" 15'-1 1/2"
18'-10" 5'-0 1/2"
5'-6" 44'-8 1/2" 5'-0 1/2"
21'-9" 5'-5" 17'-10" 5'-2 1/2" 5'-6" 2'-6" 36'-0 1/2"
'-4
'-9 1/
2"
'-1 1"
'-1
0 1 /2"
4'- 5"
'-9
3'-
9"
16'-6" 6'-11" 16'-9" 5'-7" 4'-2" 12'-5"
'-1
1 1 /2"
9'- 3 1
/2"
'-0
4'- 5"
'-1
0 1 /2"
CO
PI
ER
PL
OT
27'-9" 7'-0" 15'-5 1/2" 5'-0 1/2"
Sh re d Bi n
Sh re d Bi n
10'-6" 4'-9" 16'-9" 4'-4 1/2" 12'-4"
5'- 0"
'-4
1/ 2"
'-6
'-5
5'- 1 1
/2"
'-0
7'- 2 1
/2"
'-5
3'- 9"
'-0
7'-
7" 7'-
0" 6'-
5 1 /2"
'-5
1/ 2"
6'- 9 1
/2" 2'-
0"
14'-11 1/2" 8'-6" 7'-0" 6'-11"
3 5
5'-6" 40'-0" 2'-2 1/2"
2'-6" 5'-0 1/2"
4'-0" 2'-10" 8'-5" 38'-6 1/2" 8'-4 1/2" 10'-8" 10'-8" 10'-3 1/2"
4'- 5"
2'-
5'-
6"
'-1 1 1
/2" 7'-
2 1 /2"
1'- 8 1
/2" 5'-
6"
'-1 1/
4" 5'-
3" 2'-
4 1 /2"
5'- 3"
'-1
5'-
5 1 /2"
9'- 0 1
/4"
'-1 0"
'-9
1/ 2"
'-1
'-1
1/ 2"
5'- 2 1
/2"
'-1 0 1
/2" 5'-
7 1 /2"
'-9
1/ 4"
'-0
1/ 2"
6'- 3 1
/2"
A4.1
A4.1
A4.1
A4.1
55 6
X1
X1
4 4
3 14
24 2
1 1
X1
11'-11 1/2" 5'-1"
5'- 5"
4'- 2"
2 2
HATCH INDICATES EXTENT OF
MECHANICAL MEZZANINE ABOVE
REF
RE
F.
15'-6 1/2" 13'-3"
4X2 X2
X2
X2
8' x 8'
8' x 8'
8' x 8'
8' x 8'
8' x 8' 8' x 8'
8' x 8'8' x 8'
8' x 8' 8' x 8'
8' x 8' 8' x 8'
8' x 8' 8' x 8'
8' x 8'8' x 8'
16 15
14 14
8'- 6"
4'- 4 1
/2" 8'-
6" 4'-
4 1 /2"
8'- 6"
GENERAL FLOOR PLAN NOTES
1. GYPSUM BOARD WALLS AND CEILINGS SHALL HAVE A "LEVEL 4 SMOOTH" FINISH.
2. PROTECT ALL EXISTING FINISHED AREAS OF COMMON AREA SPACES. G.C. SHALL REPAIR ANY DAMAGED
AREAS AS A RESULT OF THE CONSTRUCTION OF THIS PROJECT.
3. G.C. SHALL MAINTAIN THE INTEGRITY OF EXISTING FIRE SEPARATIONS AT WALLS AND FLOOR / CEILING ASSEMBLIES. G.C. SHALL PROTECT EXISTING FIREPROOFING TO MAINTAIN REQUIRED FIRE RATING.
4. FLOAT NEW CONCRETE AT SUBFLOOR TO ALLOW FOR A FLUSH, SMOOTH, LEVEL FINISH. REMOVE AND
CHIP EXISTING CONCRETE FLOOR SLAB AS REQUIRED TO PROVIDE LEVEL SUBFLOOR.
5. PROVIDE FIRE RETARDANT TREATED, PRESSURE TREATED BLOCKING AT ALL WALL MOUNTED
EQUIPMENT AND MILLWORK.
6. FURNITURE SHOWN FOR COORDINATION AND DESIGN INTENT. ALL FURNITURE TO BE PROVIDED BY
TENANT, INSTALLED BY TENANT.
7. INDICATES WALL TYPE. REFER TO WALL SECTIONS.
1/8" = 1'-0"
FLOOR PLAN
AT AREA OF WORK
SHEET TITLE
SHEET
REVISED:
CHECKED
DRAWN BY
DATE
PROJECT NO.
c COPYRIGHT 2021, DESIGN EDGE, P.C. ALL
RIGHTS RESERVED. ANY COPYING OR OTHER
REPRODUCTION OF THESE DRAWINGS WITHOUT
THE PRIOR WRITTEN AUTHORIZATION OF DESIGN
EDGE, P.C. CONSTITUTES A VIOLATION OF
COPYRIGHT LAW AND WILL BE SUBJECT TO
LEGAL ACTION.
TRUE NORTHPROJECT NORTH
482 S Broadway - Suite 100 Denver, Colorado 80209 Telephone: 303-260-7277 Fax: 303-260-7282
711 N Cascade Avenue Colorado Springs, Colorado 80903 Telephone: 719-667-1972
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice. Properly destroy or return documents when no longer needed.
U.S. General Services Administration
A1.1
FLOOR PLAN - DIMENSIONAL
20165
MDR
ACO
U
SG
S/ D
O I T
R
AI
N
IN
G C
EN
TE
R
BU
IL
D
IN
G
D
EN
VE
R F
ED
ER
AL
C
EN
TE
R D
EN
VE
R , C
O
LO
R
AD
O
2/26/2021
KEYED NOTES
1 INSTALL SALVAGED DOOR, FRAME, GLAZING AND HARDWARE.
HATCH INDICATES MODIFY EXISTING RAISED FLOORING AND PROVIDE NEW AS REQUIRED THIS AREA. RAISED FLOORING HEIGHT SHALL MATCH EXISTING ADJACENT TO THE SOUTH. TIE INTO EXISTING TO REMAIN PER MANUFACTURER'S
SPECIFICATIONS.
3 PATCH AND REPAIR EXISTING WALL TO REMAIN AT DEMOLISHED PARTITION. PREPARE AS REQUIRED FOR INSTALLATION OF
NEW FINISHES.
4 NEW MILLWORK THIS ROOM. REFER TO INTERIOR ELEVATIONS.
5 INFILL EXISTING WALL AT DEMOLISHED OPENING, TO MATCH ADJACENT WALL THICKNESS AND CONSTRUCTION.
ANTICIPATED CONSTRUCTION IS 5/8" TYPE 'X' GYPSUM WALL BOARD EACH SIDE 3 5/8" METAL STUDS AT 16" O.C.
6 SYSTEMS FURNITURE SHOWN FOR COORDINATION. FINAL DESK LAYOUT, OPENING LAYOUT AND PANEL LAYOUT BY OTHERS.
7 NEW STAIR. REFER TO DETAILS.
8 EXISTING ELECTRICAL EQUIPMENT THIS ROOM TO REMAIN INTACT DURING CONSTRUCTION.
9 REPAIR WINDOW SILL, FRAME AND HEAD AS REQUIRED AT DEMOLISHED PARTITION. PATCH AND REPAIR FACE OF WALL
ABOVE AND BELOW OPENING AS REQUIRED TO INSTALL NEW FINISHES.
10 NEW OPERABLE WALL PARTITION PER SPECIFICATIONS.
11 EXISTING MEZZANINE ACCESS TO REMAIN.
12 EXISTING CEILING TRANSITION TO REMAIN.
13 PATCH AND REPAIR SUBFLOOR AS REQUIRED TO INSTALL NEW FINISHES AT ELECTRICAL FLOOR EQUIPMENT.
14 NEW WALL MOUNTED MONITOR THIS WALL. CUT NEW 72" WIDE x 48" HIGH FRT BLOCKING INTO WALL. TOP SHALL BE AT 84" A.F.F.
15 NEW WALL MOUNTED MONITOR ON SWING ARM. PROVIDE 14 GA. STUDS THIS SECTION OF WALL IN LIEU OF 20 GA. STUDS.
16 DASHED LINE INDICATES EXTENT OF NEW CHAIR RAIL THIS WALL. RE: 11 / A4.1.
35% Review 11/04/2020 65% Review 1/15/2021
REF
DN
65"
65"
86"
86"
70" 70"
86"
86"
86"
86"
60" 60"
NIC
NIC
NIC
NIC
NIC
NIC
CopierCopier Copier
Sh re d Bi n
VESTIBULE
RAMP
OPEN
OFFICE
OFFICE
OFFICE
OFFICE
EM. EXIT
ELECTRICAL
ROOM
STORAGE
OPEN
OFFICE
STORAGE
OFFICE
OFFICE
TELECOMM
MECHANICAL
IT REPAIR
MECH.
ACCESS
8216A
IT
STORAGE
ELECTRICAL
STORAGE
STORAGE
MEN'S
TOILET
WOMEN'S
TOILET
MAINTENANCE
8202A
LOBBY
STORAGE
BREAK-OUT
ROOM
HALL
8200A
HALL
HALL
TRAINING
ROOM
8230B
TRAINING
ROOM
ELECTRICAL
HALL
HALL
STORAGE
BREAK-OUT
ROOM
BREAK-OUT
ROOM
HALL
TRAINING
ROOM
ENTRY
OPEN
OFFICE
KITCHENETTE
OFFICE
OFFICE
OFFICE
STORAGE
LOBBY
8000 OFFICE
HALL
8002OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
HALL
STORAGE
CONFERENCE
HALL
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONFERENCE
OPEN
OFFICE
DN
1"
/ 1 2"
OFFICE
2613CO
PI
ER
PL
OT
LACTATION
8200D
Sh re d Bi n
Sh re d Bi n
SMALL
MEETING
ROOM
MAIL ROOM/
KITCHENETTE
16 36
20 36
36"
36"
D
36"
72"
12 36
24 72
8240B 36"
8240A 36"
8230C 36"
8230B 36"
8230A 36"
D
72"
36"
17 36
X 48 "X 36
C
15 36
14 36
13 36
12 36
01 36
X 36
X 36"
C
2600B 36"
A
08 36
09 36
36"
12 36
14 36
36"
36"
36"
07 36
X 36
TRAINING
ROOM
8230A
OFFICE
2600D
OFFICE
2600C
D
NOTE:
PROVIDE SIGN AT EACH DOOR BEGININNING WITH:
26-- 81-- 82--
REFER TO A4.1 FOR SIGN DETAIL.
SHEET TITLE
SHEET
REVISED:
CHECKED
DRAWN BY
DATE
PROJECT NO.
c COPYRIGHT 2021, DESIGN EDGE, P.C. ALL
RIGHTS RESERVED. ANY COPYING OR OTHER
REPRODUCTION OF THESE DRAWINGS WITHOUT
THE PRIOR WRITTEN AUTHORIZATION OF DESIGN
EDGE, P.C. CONSTITUTES A VIOLATION OF
COPYRIGHT LAW AND WILL BE SUBJECT TO
LEGAL ACTION.
TRUE NORTHPROJECT NORTH
482 S Broadway - Suite 100 Denver, Colorado 80209 Telephone: 303-260-7277 Fax: 303-260-7282
711 N Cascade Avenue Colorado Springs, Colorado 80903 Telephone: 719-667-1972
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice. Properly destroy or return documents when no longer needed.
U.S. General Services Administration
A1.2
FLOOR PLAN - ROOM NAMES
AND NUMBERS
20165
Author Checker
U
SG
S/ D
O I T
R
AI
N
IN
G C
EN
TE
R
BU
IL
D
IN
G
D
EN
VE
R F
ED
ER
AL
C
EN
TE
R D
EN
VE
R , C
O
LO
R
AD
O
2/26/2021
1/8" = 1'-0"
FLOOR PLAN
AT AREA OF WORK
8'-0"
8'-0"
8'-0"8'-0"
8'-0"
8'-0"
13'-4"
8'-0"
8'-0"
8'-0"
7'-6"
7'-6"
9'-0"
9'-0"
9'-0"
9'-0" 9'-0" 9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0" 9'-0"
9'-0"
9'-0" 9'-0"
9'-0"
9'-0"
8'-0"
7'-6"
9'-0"9'-0" 9'-0"
8'-0"
8'-0"
8'-0"
9'-0"
9'-0"
8'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
OPEN
A4.1
9'-0" 9'-0"
FA
FA FA
FA
FA
FA FA
FA
FA
FA
FA
FAFA
FA
FA
FA
FA
FAFA
FA FA FA
FA FA
FA FA
FA
FAFA
FA
FA
FA
FAFA
FA
FA
FA
FA
FA
FA FA FA
FAFA
FA
FA
FA FA
GENERAL CEILING PLAN NOTES
1. REFER TO FLOOR PLAN FOR WALL CONSTRUCTION
2. REFER TO ELECTRICAL PLAN FOR SWITCHING AND CIRCUITING OF LIGHTS.
3. LIGHTS AND DIFFUSERS SHOWN FOR COORDINATION ONLY. RE: MECHANICAL AND ELECTRICAL
DRAWINGS FOR QUANTITY AND TYPE.
4. COORDINATE LIGHT FIXTURE LOCATION WITH DUCTWORK. NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR
TO INSTALLATION.
5. CENTER LIGHT FIXTURE IN ROOM UNLESS OTHERWISE NOTED OR DIMENSIONED.
6. INFILL AREAS OF GYPSUM BOARD CEILING SHALL HAVE A FINISH TO MATCH EXISTING ADJACENT TO
REMAIN.
7. REFER TO FIRE PROTECTION DRAWINGS FOR DETAILED SPRINKLER AND FIRE ALARM INFORMATION.
8. SEAL ALL WALL PENETRATIONS WITH UL FIRE RATED PAST PER IBC SECTION 714.
9. INDICATES CEILING HEIGHT.XX'-XX"
CEILING PLAN LEGEND
2' x 4' LIGHT FIXTURE
RE: ELECTRICAL DRAWINGS
2' x 2' LIGHT FIXTURE
RE: ELECTRICAL DRAWINGS
SUPPLY AIR DIFFUSER
RE: MECHANICAL DRAWINGS
RETURN AIR GRILLE
RE: MECHANICAL DRAWINGS
FIRE SPRINKLER
RE: FIRE PROTECTION DRAWINGS
EXIT SIGN
RE: ELECTRICAL DRAWINGS
FIRE ALARM DEVICE
RE: FIRE PROTECTION DRAWINGSFA
EXHAUST GRILLE
RE: MECHANICAL DRAWINGS
LINEAR LIGHT FIXTURE
RE: ELECTRICAL DRAWINGS
SHEET TITLE
SHEET
REVISED:
CHECKED
DRAWN BY
DATE
PROJECT NO.
c COPYRIGHT 2021, DESIGN EDGE, P.C. ALL
RIGHTS RESERVED. ANY COPYING OR OTHER
REPRODUCTION OF THESE DRAWINGS WITHOUT
THE PRIOR WRITTEN AUTHORIZATION OF DESIGN
EDGE, P.C. CONSTITUTES A VIOLATION OF
COPYRIGHT LAW AND WILL BE SUBJECT TO
LEGAL ACTION.
TRUE NORTHPROJECT NORTH
482 S Broadway - Suite 100 Denver, Colorado 80209 Telephone: 303-260-7277 Fax: 303-260-7282
711 N Cascade Avenue Colorado Springs, Colorado 80903 Telephone: 719-667-1972
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice. Properly destroy or return documents when no longer needed.
U.S. General Services Administration
A2.1
REFLECTED CEILING PLAN
20165
MDR
ACO
U
SG
S/ D
O I T
R
AI
N
IN
G C
EN
TE
R
BU
IL
D
IN
G
D
EN
VE
R F
ED
ER
AL
C
EN
TE
R D
EN
VE
R , C
O
LO
R
AD
O
2/26/2021
1/8" = 1'-0"
REFLECTED CEILING PLAN
AT AREA OF WORK
KEYED NOTES
1 EXISTING GYPSUM WALL BOARD CEILING TO REMAIN. PATCH AND REPAIR AS REQUIRED TO INSTALL NEW FINISHES.
2 INSTALL NEW GYPSUM WALL BOARD CEILING TO MATCH EXISTING ADJACENT.
3 NEW GYPSUM BOARD SOFFIT AT OPERABLE WALL. REFER TO DETAILS.
4 PATCH AND REPAIR EXISTING GYPSUM BOARD SOFFIT AND CEILINGS AS REQUIRED AT DEMOLISHED PARTITIONS. PREPARE
FOR INSTALLATION OF NEW FINISHES.
INSTALL NEW GYPSUM WALL BOARD HEADER. CONSTRUCTION SHALL BE 5/8" TYPE 'X' GYPSUM WALL BOARD EACH SIDE AND BOTTOM OF 3 5/8" 20 GA. METAL STUDS AT 16" O.C. FROM 8'-6" A.F.F TO STRUCTURE ABOVE. GYPSUM BOARD SHALL EXTEND
6" MIN. ABOVE ADJACENT ACT CEILING.
6 EXISTING BULKHEAD THIS LOCATION TO REMAIN.
7 EXISTING CEILING THIS ROOM TO REMAIN.
35% Review 11/04/2020 65% Review 1/15/2021
13'-1"
1"2'-6"2'-6"3'-0"2'-6"2'-6"
2'-6" 2'-6" 3'-0" 2'-6" 2'-6" 1"
SI
NK
R
IM
2'-
+/-1'-
8" 3'-
0"
SOLID SURFACE (SS-1) COUNTERTOP WITH
INTEGRAL 4" HIGH BACK & SIDESPLASH
NEW REFRIGERATOR
RE: PLUMBING DRAWINGS
PROVIDE ALL REQUIRED HARDWARE AT
DRAWERS AND DOORS
24" DEEP PLASTIC LAMINATE (PL-1) BASE
CABINETS WITH WHITE MELAMINE INTERIORS
AND ADJUSTABLE SHELF
SINK AND FAUCET PER PLUMBING DRAWINGS.
SINK RIM HEIGHT SHALL NOT EXCEED 34" A.F.F.
12" DEEP PLASTIC LAMINATE (PL-1) WALL
CABINETS WITH WHITE MELAMINE INTERIORS
AND ADJUSTABLE SHELVES
A4.1
A4.1
2" 2'-6" 3'-0" 3'-0" 2"
3'- 0"
+/-1'- 8"
SI
NK
R
IM
2'-
" SOLID SURFACE (SS-1) COUNTERTOP WITH
INTEGRAL 4" HIGH BACK & SIDESPLASH
NEW REFRIGERATOR
RE: PLUMBING DRAWINGS
PROVIDE ALL REQUIRED HARDWARE AT
DRAWERS AND DOORS
24" DEEP PLASTIC LAMINATE (PL-1) BASE
CABINETS WITH WHITE MELAMINE INTERIORS
AND ADJUSTABLE SHELF
SINK AND FAUCET PER PLUMBING DRAWINGS.
SINK RIM HEIGHT SHALL NOT EXCEED 34" A.F.F.
12" DEEP PLASTIC LAMINATE (PL-1) WALL
CABINET WITH INTEGRAL MICROWAVE SHELF
12" DEEP PLASTIC LAMINATE (PL-1) WALL
CABINETS WITH WHITE MELAMINE INTERIORS
AND ADJUSTABLE SHELVES
A4.1
A4.1
8'-10" 2"
2'-6" 3'-0" 3'-0" 2"
3'-4" F.V.
7'- 0"
PROVIDE FRT BLOCKING IN
WALL AS REQUIRED TO
MOUNT MONITOR
MONITOR, SUPPLIED BY G.C.
INSTALLED BY G.C.
G.C. SHALL PROVIDE WALK PRIOR TO
INSTALLING BLOCKING IN WALL TO DETERMINE
EXACT LOCATION OF EACH MONITOR
1'-9" 3'-0" 2'-6" 1"
SOLID SURFACE (SS-1) COUNTERTOP WITH
INTEGRAL 4" HIGH BACK & SIDESPLASH
NEW REFRIGERATOR
RE: PLUMBING DRAWINGS
PROVIDE ALL REQUIRED HARDWARE AT
DRAWERS AND DOORS
24" DEEP PLASTIC LAMINATE (PL-1) BASE
CABINETS WITH WHITE MELAMINE INTERIORS
AND ADJUSTABLE SHELF3'-4" F.V. 7'-4"
3'- 0"
+/-1'- 8"
SI
NK
R
IM
2'-
SINK AND FAUCET PER PLUMBING DRAWINGS.
SINK RIM HEIGHT SHALL NOT EXCEED 34" A.F.F.
3'-4" F.V. 1'-9" 3'-0" 2'-6" 1"
12" DEEP PLASTIC LAMINATE (PL-1) WALL
CABINET WITH INTEGRAL MICROWAVE SHELF
12" DEEP PLASTIC LAMINATE (PL-1) WALL
CABINETS WITH WHITE MELAMINE INTERIORS
AND ADJUSTABLE SHELVES
A4.1
A4.1
A4.1
24" DEEP PLASTIC LAMINATE (PL-1) BASE
CABINETS WITH WHITE MELAMINE INTERIORS
AND ADJUSTABLE SHELF
3'-0" 3'-0"
6'-0"
2'-
1'-
8" 3'-
0"
3'-0" 3'-0"
6'-0"
PROVIDE ALL REQUIRED HARDWARE AT
DRAWERS AND DOORS
SOLID SURFACE (SS-1) COUNTERTOP WITH
INTEGRAL 4" HIGH BACKSPLASH
12" DEEP PLASTIC LAMINATE (PL-1) WALL
CABINETS WITH WHITE MELAMINE INTERIORS
AND ADJUSTABLE SHELVES
1. DROP-IN SINK RIM HEIGHT SHALL NOT EXCEED 34" ABOVE FINISH FLOOR.
2. COUNTERTOPS WITHOUT SINKS SHALL NOT EXCEED 34" ABOVE FINISH FLOOR.
3. PROVIDE FRT BLOCKING IN NEW WALLS AND CUT FRT BLOCKING INTO EXISTING
WALLS AS REQUIRED AT ALL WALL MOUNTED MILLWORK AND EQUIPMENT.
4. PROVIDE FINISHED END PANEL AT ALL EXPOSED CABINET FACES.
5. ALL KITCHEN EQUIPMENT INCLUDING: REFRIGERATORS, MICROWAVES, ETC. IS
SUPPLIED BY TENANT, INSTALLED BY G.C. GENERAL CONTRACTOR SHALL
COORDINATE WITH OWNER AND ARCHITECT THE APPROPRIATE TIME FOR DELIVERY
OF OWNER FURNISHED EQUIPMENT.
6. REFER TO PLUMBING DRAWINGS FOR ALL PIPING REQUIREMENTS, ROUTING,
PUMPING, WALL BOXES, ETC.
7. PROVIDE CABINET FILLERS AT ALL GAPS. CABINET FILLER SHALL NOT EXCEED 2" IN
WIDTH.
GENERAL MILLWORK NOTES
CENTER OPERABLE WALL ON
EXISTING GIRDER ABOVE
REPAIR FIREPROOFING AS
REQUIRED
350T-150-43 CONTINUOUS TOP
TRACK. ANCHOR TO CROSS
BRACE WITH (3) #10 SCREWS
3 5/8" 20 GA. METAL STUDS AT 16"
O.C. MAX. FROM 8' A.F.F TO 12"
MINIMUM ABOVE CEILING LINE.
PROVIDE SOUND BATT
INSULATION IN STUD CAVITY
5/8" TYPE 'X' GYPSUM WALL
BOARD EXTENDS 12" MINIMUM
ABOVE CEILING LINE.
CEILING GRID EDGE ANGLE
ACOUSTIC TILE CEILING
OPERABLE WALL TRACK WITH
INTEGRAL GYPSUM LEDGE
SOUND SWEEPS
EXTEND SOUND BATT INSULATION
OVER GYPSUM BOARD SOFFIT
5/8" TYPE 'X' GYPSUM BOARD SOFFIT
350S162-43 CROSS BRACE AT 48" O.C. MAX.
OPERABLE WALL PANELS
1'- 0"
CONTINUOUS C12x25 CHANNEL
COORDINATE ANCHOR BOLT
SPACING WITH OPERABLE WALL
MANUFACTURER
OPERABLE WALL ANCHOR BOLTS BY
OPERABLE WALL MANUFACTURER
L6x4x1/4 x 0'-6" CLIP (L.L.V.)
3/16"
3/16"
L4x4x1/4 HANGER AT 5'-0" O.C. MAX.
350S162-43 BRACE AT 48" O.C. MAX.
TO UNDERSIDE EXISTING DECK,
EACH SIDE
3/16"
3/16" L6x4x1/4 x 0'-6" CLIP (L.L.V.)
REMOVE FIREPROOFING AS
REQUIRED TO WELD CLIP TO
BOTTOM OF BEAM
CONTINUOUS L6x4x1/4 ANGLE
L4x4x1/4 BRACE AT EACH HANGER
3/16" 4"
3/16" 3/16"
1 1 /2"
6" 6"
6"
3 1
/2"
3'- 0"
1'- 4"
4" 2'-
2'-1"
1'-0"
2'-0"1"
PROVIDE FRT BLOCKING AS REQUIRED
TO INSTALL WALL MOUNTED CABINETS.
12" WALL CABINET WITH WHITE
MELAMINE INTERIORS
PROVIDE PLASTIC LAMINATE FINISH AT
ALL EXPOSED CABINET FACES
ADJUSTABLE WHITE MELAMINE
SHELVES. PROVIDE ALL MOUNTING
BRACKETS.
4" ALUMINUM PULLS
INTEGRAL 4" HIGH BACKSPLASH
SOLID SURFACE COUNTERTOP
PROVIDE ALL REQUIRED HARDWARE
AT DRAWERS
4" ALUMINUM PULLS
24" DEEP BASE CABINET WITH WHITE
MELAMINE INTERIORS
PROVIDE PLASTIC LAMINATE FINISH
AT ALL EXPOSED CABINET FACES
TOE KICK TO MATCH ROOM BASE
1 1 /2"
2'- 5"
3 1 /2"
2'- 0"
2'- 4"
4" 2'-
" T
OP
O
F
SI
NK
R
IM
2'-1"
1'-0"
2'-0"1"
PROVIDE FRT BLOCKING AS REQUIRED
TO INSTALL WALL MOUNTED CABINETS.
12" WALL CABINET WITH WHITE
MELAMINE INTERIORS
PROVIDE PLASTIC LAMINATE FINISH AT
ALL EXPOSED CABINET FACES
ADJUSTABLE WHITE MELAMINE SHELF.
PROVIDE ALL MOUNTING BRACKETS.
4" ALUMINUM PULLS
INTEGRAL 4" HIGH BACKSPLASH
SOLID SURFACE COUNTERTOP
SINK AND FAUCET
RE: PLUMBING DRAWINGS
4" ALUMINUM PULLS
24" DEEP BASE CABINET WITH WHITE
MELAMINE INTERIORS
PROVIDE PLASTIC LAMINATE FINISH
AT ALL EXPOSED CABINET FACES
TOE KICK TO MATCH ROOM BASE
1 1 /2"
6" 1'-
3 1 /2"
3'- 0"
1'- 4"
4" 2'-
2'-1"
2'-0"1"
PROVIDE FRT BLOCKING AS REQUIRED
TO INSTALL WALL MOUNTED CABINETS.
12" WALL CABINET WITH WHITE
MELAMINE INTERIORS
PROVIDE PLASTIC LAMINATE FINISH AT
ALL EXPOSED CABINET FACES
PLASTIC LAMINATE MICROWAVE SHELF,
SIDE WALLS, AND BACK WALL
4" ALUMINUM PULLS
INTEGRAL 4" HIGH BACKSPLASH
SOLID SURFACE COUNTERTOP
ADJUSTABLE WHITE MELAMINE SHELF.
PROVIDE ALL MOUNTING BRACKETS.
4" ALUMINUM PULLS
24" DEEP BASE CABINET WITH WHITE
MELAMINE INTERIORS
PROVIDE PLASTIC LAMINATE FINISH
AT ALL EXPOSED CABINET FACES
TOE KICK TO MATCH ROOM BASE
PROVIDE ALL REQUIRED HARDWARE
AT DRAWERS
INTEGRAL 4" HIGH BACKSPLASH
SOLID SURFACE COUNTERTOP
ADJUSTABLE WHITE MELAMINE SHELF.
PROVIDE ALL MOUNTING BRACKETS.
4" ALUMINUM PULLS
24" DEEP BASE CABINET WITH WHITE
MELAMINE INTERIORS
PROVIDE PLASTIC LAMINATE FINISH
AT ALL EXPOSED CABINET FACES
TOE KICK TO MATCH ROOM BASE
PROVIDE ALL REQUIRED HARDWARE
AT DRAWERS
PROVIDE FRT BLOCKING AS REQUIRED
TO INSTALL WALL MOUNTED CABINETS.
12" WALL CABINET WITH WHITE
MELAMINE INTERIORS
PROVIDE PLASTIC LAMINATE FINISH AT
ALL EXPOSED CABINET FACES
ADJUSTABLE WHITE MELAMINE
SHELVES. PROVIDE ALL MOUNTING
BRACKETS.
4" ALUMINUM PULLS
3'- 0"
1'- 4"
4" 2'-
2'-1"
1" 2'-0"
1 1 /2"
6" 1'-
3 1 /2"
2'-
STAIN GRADE 1x6 CHAIR RAIL WITH EASED EDGES.
SPECIES, GRAIN AND STAIN TO MATCH DOORS.
FROSTED 1/4" THICK LEXAN SIGN
1" 3/4
1 1
/2" 3/4
1/4
3/4
1"
6"
1" 7" 1"
9"
ROOM NAME
CONTINUED
1/2
5" 1/2
1/2" 8" 1/2"
STAINLESS STEEL OR CLEAR ANODIZED ALUMINUM
STANDOFF. 1/2" DIAMETER x 1/2" DEPTH.
RAISED TEXT LINES 1/32" DEPTH. FINAL TEXT FONT
AND ROOM NAME TO BE APPROVED BY TENANT.
BRAILLE ZONE TO COMPLY WITH ALL ABAAS
SECTION 704 REQUIREMENTS.
SHEET TITLE
SHEET
REVISED:
CHECKED
DRAWN BY
DATE
PROJECT NO.
c COPYRIGHT 2021, DESIGN EDGE, P.C. ALL
RIGHTS RESERVED. ANY COPYING OR OTHER
REPRODUCTION OF THESE DRAWINGS WITHOUT
THE PRIOR WRITTEN AUTHORIZATION OF DESIGN
EDGE, P.C. CONSTITUTES A VIOLATION OF
COPYRIGHT LAW AND WILL BE SUBJECT TO
LEGAL ACTION.
482 S Broadway - Suite 100 Denver, Colorado 80209 Telephone: 303-260-7277 Fax: 303-260-7282
711 N Cascade Avenue Colorado Springs, Colorado 80903 Telephone: 719-667-1972
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
Do not remove this notice. Properly destroy or return documents when no longer needed.
U.S. General Services Administration
A4.1
INTERIOR ELEVATIONS
20165
MDR
ACO
U
SG
S/ D
O I T
R
AI
N
IN
G C
EN
TE
R
BU
IL
D
IN
G
D
EN
VE
R F
ED
ER
AL
C
EN
TE
R D
EN
VE
R , C
O
LO
R
AD
O
2/26/2021
3/8" = 1'-0"
ELEVATION
AT LOBBY 3/8" = 1'-0"
ELEVATION
AT BREAK ROOM 3/8" = 1'-0"
ELEVATION
TYPICAL MONITOR MOUNTING3/8" = 1'-0"
ELEVATION
AT KITCHENETTE 3/8" = 1'-0"
ELEVATION
AT MAILROOM
1" = 1'-0"
DETAIL
AT OPERABLE WALL1" = 1'-0"
SECTION
AT MILLWORK 1" = 1'-0"
SECTION
AT MILLWORK 1" = 1'-0"
SECTION
AT MILLWORK 1" = 1'-0"
SECTION
AT MILLWORK
1 1/2" = 1'-0"
DETAIL
3" = 1'-0"
DETAIL
65% Review 1/15/2021
EXISTING STRUCTURE ABOVE TO REMAIN
PROVIDE KICKERS OR KING STUDS TO
STRUCTURE ABOVE AT 48" O.C. MAX.
PROVIDE KICKERS OR KING STUDS TO
STRUCTURE ABOVE AT 48" O.C. MAX.
EXTEND GYPSUM WALL BOARD 6" MIN.
ABOVE ADJACENT CEILING LINE.
GRID EDGE ANGLE, EACH SIDE OF WALL
CONTINUOUS BOTTOM TRACK
3 5/8" 20 GA. METAL STUDS AT 16" O.C. MAX.
SOUND BATT INSULATION IN STUD CAVITY
5/8" TYPE 'X' GYPSUM WALL BOARD EACH SIDE
EXISTING STRUCTURE ABOVE TO REMAIN
PROVIDE DEFLECTION CUFF "SLIP-TRACK" AT TOP
OF WALL TO ALLOW FOR 2" MIN. DEFLECTION
1/4" MAX. SEALANT JOINT, EACH SIDE
EXTEND GYPSUM WALL BOARD 6" MIN.
ABOVE ADJACENT CEILING LINE.
GRID EDGE ANGLE, EACH SIDE OF WALL
CONTINUOUS BOTTOM TRACK
3 5/8" 20 GA. METAL STUDS AT 16" O.C. MAX.
SOUND BATT INSULATION IN STUD CAVITY
5/8" TYPE 'X' GYPSUM WALL BOARD EACH SIDE
1/2" RESILIENT CHANNEL AT 24" O.C. MAX. FROM
FLOOR TO UNDERSIDE STRUCTURE ABOVE.
1/4" MAX. ACOUSTIC SELANT AND BACKER ROD
TRAINING ROOM SIDE
EXISTING STRUCTURE ABOVE TO REMAIN
PROVIDE KICKERS OR KING STUDS TO
STRUCTURE ABOVE AT 48" O.C. MAX.
PROVIDE KICKERS OR KING STUDS TO
STRUCTURE ABOVE AT 48" O.C. MAX.
EXTEND GYPSUM WALL BOARD 6" MIN.
ABOVE ADJACENT CEILING LINE.
GRID EDGE ANGLE
CONTINUOUS BOTTOM TRACK
3 5/8" 20 GA. METAL STUDS AT 16" O.C. MAX.
SOUND BATT INSULATION IN STUD CAVITY
5/8" TYPE 'X' GYPSUM WALL BOARD
EXISTING STRUCTURE ABOVE TO REMAIN
PROVIDE KICKERS OR KING STUDS TO
STRUCTURE ABOVE AT 48" O.C. MAX.
PROVIDE KICKERS OR KING STUDS TO
STRUCTURE ABOVE AT 48" O.C. MAX.
EXTEND GYPSUM WALL BOARD 6" MIN.
ABOVE ADJACENT CEILING LINE.
GRID EDGE ANGLE, EACH SIDE OF WALL
EXISTING CONTINUOUS BOTTOM TRACK
(ASSUMED)
EXISTING 3 5/8" 20 GA. METAL STUDS AT 16"
O.C. MAX. (ASSUMED)
INSTALL NEW SOUND BATT INSULATION IN
EXISTING STUD CAVITY
EXISTING 5/8" TYPE 'X' GYPSUM WALL BOARD
REMOVE GYPSUM WALL BOARD ON ONE SIDE, AS
REQUIRED, TO INSTALL NEW BATT INSULATION
8'- 0"
E
XI
ST
IN
G W
AL
L H
EI
GH
T
NEW METAL STUDS SISTERED ONTO
EXISTING TO REMAIN.
NEW 5/8" TYPE 'X' GYPSUM WALL BOARD
EACH SIDE
REMOVE EXISTING LIGHTING COVE,
FRAMING, FINISHES, ETC. COMPLETELY.
EXISTING SOFFIT AROUND
DUCTWORK TO REMAIN
EXISTING STRUCTURE ABOVE TO REMAIN
PROVIDE KICKERS OR KING STUDS TO
STRUCTURE ABOVE AT 48" O.C. MAX.
PROVIDE KICKERS OR KING STUDS TO
STRUCTURE ABOVE AT 48" O.C. MAX.
EXTEND GYPSUM WALL BOARD ABOVE
CEILIGN TO STRUCTURE.
GRID EDGE ANGLE, EACH SIDE OF WALL
CONTINUOUS BOTTOM TRACK
3 5/8" 20 GA. METAL STUDS AT 16" O.C. MAX.
SOUND BATT INSULATION IN STUD CAVITY
5/8" TYPE 'X' GYPSUM WALL BOARD EACH SIDE
1 HOUR RATED WALL CONSTRUCTION
UL NO: U419
EXISTING STRUCTURE ABOVE TO REMAIN
PROVIDE KICKERS OR KING STUDS TO
STRUCTURE ABOVE AT 48" O.C. MAX.
PROVIDE KICKERS OR KING STUDS TO
STRUCTURE ABOVE AT 48" O.C. MAX.
EXTEND GYPSUM WALL BOARD 6" MIN.
ABOVE ADJACENT CEILING LINE.
GRID EDGE ANGLE, EACH SIDE OF WALL
CONTINUOUS BOTTOM TRACK
3 5/8" 20 GA. METAL STUDS AT 16" O.C. MAX.
SOUND BATT INSULATION IN STUD CAVITY
5/8" TYPE 'X' GYPSUM WALL BOARD EACH SIDE
PROVIDE RAISED FLOOR PEDESTAL AT AS
RECOMMENDED BY RAISED FLOOR
MANUFACTURER UNDER WALL CENTERLINE.
EXISTING STRUCTURE ABOVE TO REMAIN
PROVIDE KICKERS OR KING STUDS TO
STRUCTURE ABOVE AT 48" O.C. MAX.
PROVIDE KICKERS OR KING STUDS TO
STRUCTURE ABOVE AT 48" O.C. MAX.
EXTEND GYPSUM WALL BOARD 6" MIN.
ABOVE ADJACENT CEILING LINE.
GRID EDGE ANGLE, EACH SIDE OF WALL
CONTINUOUS BOTTOM
TRACK ON SLAB
3 5/8" 20 GA. METAL STUDS AT 16" O.C. MAX.
SOUND BATT INSULATION IN STUD CAVITY
5/8" TYPE 'X' GYPSUM WALL BOARD EACH SIDE
PROVIDE RAISED FLOOR PEDESTAL AT
PERIME…