Sol_140F0621R0013_Amd_0002.pdf
PDF 164 KB Posted
- Attached to
- THERMAL ENVELOPE & HVAC UPGRADE Federal contract opportunity
- Solicitation number
- 140F0621R0013
About this file
This document is an amendment to a solicitation for the thermal envelope and HVAC upgrade at the National Eagle and Wildlife Property Repository. The scope of work includes renovating and upgrading the thermal envelope and HVAC systems, adding a 184 square foot Sally Port, constructing a new conditioned Beetle Colony Room and vestibule/locker area in the Warehouse. The amendment provides responses to contractor questions, lists additional interested vendors, and extends the response due date to 19 May 2021 at 1900 hours local time. Contractors must acknowledge receipt of this amendment. The questions and answers clarify details around potential hazardous materials, water intrusion points, new insulation specifications, page count requirements, and the list of interested subcontractors.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140F0621R0013_Amd_0003.pdf | ||
| Sol_140F0621R0013_Amd_0001.pdf | ||
| Amend 0001 Atch 2 Eagle Repository - Bid Schedule_rev_0001.pdf | ||
| Amend 0001 Atch 1 Eagle Repository - Electrical Info_0001.pdf | ||
| Atch 5 Eagle Repository Past Perf Quest.doc | DOC document | |
| Atch 1 Eagle Repository Specs.pdf | ||
| Atch 4 Eagle Repository DOL Wage Det.pdf | ||
| Atch 2 Eagle Repository Drawings.pdf | ||
| Sol_140F0621R0013.pdf | ||
| Atch 3 Eagle Repository Submittals.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(x)
140F0621R0013 x x
1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE
RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR
OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
x
F06
Lakewood CO 80228-1807
134 UNION BOULEVARD
LAKE PLAZA NORTH
FWS, DIVISION OF CONTRACTING AND GE
21-03205/14/20210002
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
FACILITY CODE CODE
10B. DATED (SEE ITEM 13)
10A. MODIFICATION OF CONTRACT/ORDER NO.
9B. DATED (SEE ITEM 11)
9A. AMENDMENT OF SOLICITATION NO.
CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)
7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY
PAGE OF PAGES
4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)
1. CONTRACT ID CODE
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
04/07/2021
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority) appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
E. IMPORTANT: Contractor is not is required to sign this document and return __________________ copies to the issuing office.
ORDER NO. IN ITEM 10A.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
see page 2
Legacy Doc #: FWS
Period of Performance: 06/01/2021 to 05/31/2022
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED
(Signature of person authorized to sign) (Signature of Contracting Officer)
Timothy Officer
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
Previous edition unusable
Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .
Solicitation Amendment
Document 140F0621R0013-0002
Document Title Rehab Eagle Repository Thermal Envelop and HVAC Page 2 of 3
A. The purpose of this amendment is to respond to contractor questions, provide Government responses and provide an updated interested vendors list.
B. The following contractor questions and Government response are provided for consideration:
Contractor Question 1: The documents indicate there maybe or are hazardous materials in the structure. They also indicate that tests have been conducted, reports generated, and the resolution is part of another project. Can I obtain the report of the Hazards materials and if any remain or have all been abated?
Government Response: We are not aware of any testing. The Government will investigate this matter.
Contractor Question 2: During the site visit we noted there are a few penetrations or gutter issues causing water to enter the structure. Do you have additional info and or specific points of entry?
Government Response: The roof gutter located on the exterior of the eagle observation hall overflows during large rain/snowmelt events due to improperly sized and angled downspouts and gutters. These gutters need to be properly sized and angled. Also, the building currently has extremely poor drainage from the roof which causes water and snowmelt to spill over on the loading dock, stairs, and sidewalk utilized to access the crematory.
Contractor Question 3: E1 note #17 references removal and reinstallation of high bay lighting for insulation as necessary but can only find new insulation call outs for the exterior walls of the property storage area per sheets A4 & A9 - can you confirm if there is new insulation for the ceiling also or only walls in this area of the building?
Government Response: There is no, new insulation called out for the ceiling of the Property Storage Area, just the walls.
Contractor Question 4: Do cover pages, table of contents, cover letter, and page dividers count towards the page count on the technical proposal?
Government Response: No.
Contractor Question 5: Will the list of subcontracts pages count towards page count? The resumes took quite a bit of pages as well.
Government Response: Our intent was to list only the major, key subcontractors as cited elsewhere. We've not requested resumes, the information we've asked for should be readily available and tailored for this project.
Solicitation Amendment
Document 140F0621R0013-0002
Document Title Rehab Eagle Repository Thermal Envelop and HVAC Page 3 of 3
C. The following vendors have shown interest in the project:
Firm POC Phone
Ward Construction Co. Stan Ward 303-789-9970 Sky Blue Builders Jeff Anker 303.220.0339 Spectrum GC Graham Johnson 303-329-8003 RJS Construction Chad Bakken (509)452-0857 HD INC. Michael Murphey (303) 485-9461 Greenstone Construction Inc. Justin Lindteigen 701-293-1200 E-Corp Kris Kremin 970-217-7734 JCI Molly Telles RK Mechanical Eric Anthony RK Mechanical Michael Harrison Elite Electric Todd Johnson Elite Electric Jeff Croner St. Andrews Vicki Wren St. Andrews Ryan Burham SMH Shane Henry SGLC Consulting Grant Cunningham 720-412-3433 TopGard LLC Clay Spurgeon 317-506-7643
D. The response due date and time is extended to Wednesday, 19 May 2021, 1900 hours local time.
Please provide acknowledgement of this amendment.