Attachment_13_Bldg_135_Revision__2_0003.pdf
PDF 6 MB Posted
- Attached to
- MAIN ENTRANCE REDESIGN SIPI
- Solicitation number
- 140A2326R0041
About this file
This document is a comprehensive asbestos survey report for Building 135 (Child Care Center) at Southwestern Indian Polytechnic Institute in Albuquerque, New Mexico, conducted by ARS Aleut Construction, LLC.
The survey was performed on November 9, 2020, covering 7,000 square feet across a single-story educational facility. Nine homogeneous areas (HAs) of suspect asbestos-containing materials were identified during visual inspection, including vinyl floor tiles, pipe jackets, drywall with textured finishes, ceiling tiles, cove base mastic, sink vapor barriers, and exterior stucco. A total of 45 bulk samples were collected and analyzed using Polarized Light Microscopy (PLM) by AmeriSci Richmond, Inc. All analytical results were below the regulatory threshold of 1% asbestos content, with no asbestos detected (NAD) in any samples tested. Quality control samples were split and analyzed by a different PLM analyst to verify results. The survey concluded that building components can be treated as non-asbestos-containing materials. The report recommends that construction and demolition debris be treated as C&D waste disposed at an appropriate landfill, and that untested elbows in mechanical systems built in 1971 throughout the college be sampled or treated as asbestos-containing if removed or disturbed during renovation or demolition activities. Qualified surveyors included Jose J. Sosa (PE, CIH) and Robert Provost (IHT/RSO), with survey conducted under Contract No. 140A1618D0006/140A1620F0161.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Survey for Building 135
Southwestern Indian Polytechnic Institute 9169 Coors Blvd NW, Albuquerque, NM 87120
Prepared by:
ARS Aleut Construction 4100 Lafayette Center Dr., Suite 115, Chantilly, VA 20151
(614) 937-6664
February 2021
Revised 04/15/2021
Comprehensive Asbestos Survey Southwestern Indian Polytechnic Institute (SIPI)
Albuquerque, NM i ARS Aleut Construction, LLC
Asbestos Survey, For Building 135
9169 Coors Blvd NW, Albuquerque, NM 87120
Contract No. 140A1618D0006/140A1620F0161 Prepared for:
Southwestern Indian Polytechnic Institute 9169 Coors Blvd NW, Albuquerque, NM 87120
Prepared by:
ARS Aleut Construction, LLC.
4100 Lafayette Center Dr., Suite 115, Chantilly, VA 20151
(614) 937-6664
X Jose J. Sosa, P.E., CIH CIH No. 5429
X Robert Provost, IHT/RSO
February 2021 ii
TABLE OF CONTENTS
1.0 EXECUTIVE SUMMARY
1.1 Asbestos-Containing Material Summary
2.0 BUILDING INFORMATION
3.0 LIMITATIONS OF THE SURVEY
4.0 ASBESTOS SURVEY
4.1 ACM Survey Findings: Building 135
4.2 Asbestos Survey Protocol
4.3 Regulatory Review
5.0 CONCLUSIONS
6.0 RECOMMENDATIONS
7.0 TABLES AND RESULTS
APPENDICES
Appendix A: Chain of Custody Form & Laboratory Analytical Report Appendix B: Positive Sample Photos Appendix C: Floor Plans Appendix D: Certifications iii
LIST OF ACRONYMS
AAC ARS ALEUT CONSTRUCTION
A/C AIR CONDITIONER
ACBM(s) ASBESTOS-CONTAINING BUILDING MATERIAL (S) ACM(s) ASBESTOS-CONTAINING MATERIAL (S)
AMO AMOSITE
BLDG BUILDING
BUR BUILT-UP ROOF
CBS CONCRETE BLOCK SYSTEM
COMP COMPOUND
CRY CHRYSOTILE
CT CEILING TILE (S)
DECO DECORATIVE
DIR DIRECTIONAL
D/I DROP-IN
D/W DRYWALL
EXT EXTERIOR
F/P FISSURES/PINHOLES
HA HOMOGENEOUS AREA
HVAC HEATING, VENTILATING AND AIR CONDITIONING
INT INTERIOR
JT JOINT
LF LINEAR FEET
LT LIGHT
L/F LONG FISSURES
L/W LENGTHWISE
N/A NOT APPLICABLE
NAD NO ASBESTOS DETECTED
NA NOT ANALYZED
NO NUMBER
NA/PS NOT ANALYZED / POSITIVE STOP
O&M OPERATION AND MAINTENANCE
PLM POLARIZED LIGHT MICROSCOPY
QA/QC QUALITY ASSURANCE/QUALITY CONTROL
RACM(s) REGULATED ASBESTOS-CONTAINING MATERIAL (S)
RVF ROLLED VINYL FLOORING
SF SQUARE FEET
S/F STOREFRONT
TSI THERMAL SYSTEM INSULATION
VBB VINYL BASEBOARD
VFT VINYL FLOOR TILE
VTR VENT-THROUGH-ROOF
1.0 EXECUTIVE SUMMARY
ARS Aleut Construction, LLC (AAC) was retained by the Southwestern Indian Polytechnic Institute (SIPI) to perform a comprehensive Asbestos Containing Materials (ACM) Survey, of structures located within the boundaries of the Institute. The Institute is located at 9169 Coors Blvd NW, Albuquerque, NM 87120. This report contains the findings and results of the inspection of Building 135
1.1 Asbestos-Containing Material Summary
The scope of the survey included to visually inspect and identify all visible building components and finishes considered as suspect asbestos containing materials. The survey was performed according to current Environmental Protection Agency’s (EPA) and the State of New Mexico’s regulations. Federal and state regulations outline the procedures for the identification and sampling guidelines of suspect asbestos containing materials.
Eight (8) homogeneous areas (HA’s) of suspect ACM were identified during the visual inspection of Building 135. Homogeneous Area 6 was later redacted because the HA was incorrectly identified and was not present in the building. Analytical results from the samples collected in Building 135 were below the regulatory threshold of 1%.
Table 1 in Section 7 of this report contains the inventory and the number of samples collected during the inspection and Table 2 is the PLM results of the QC’s taken throughout the building. Appendix A contains the chain of custody, sample inventory forms and the analytical report from the laboratory. Appendix B contains the pictures of building materials determined to contain asbestos above the regulatory threshold.
Appendix C contains floor plans showing the location of the samples collected. Appendix D is the surveyor’s certifications.
2.0 BUILDING INFORMATION
Building Name Child Care Center
Year Built 1007
Building Number 135
Area of Survey 7,000 SF
Building Type Educational
# of Floors 1
Purpose of ACM Survey Renovation
Building Survey Date
11/10/2020
3.0 LIMITATIONS OF THE SURVEY
ARS Aleut Construction (AAC) performed a comprehensive Asbestos Containing Material (ACM) Survey. The following limitations apply to the scope of our services:
• Survey performed was non-destructive, the inspectors made every attempt to identify accessible suspect materials, suspect materials concealed behind chases or other parts of the building requiring removal were not sampled.
• The quantities provided are visual estimations and should not be utilized as scope quantities for abatement.
• Roofs under warranty were not sampled to avoid nullifying or affecting the warranty.
• The inspectors made up to three attempts to access locked spaces. Rooms or areas with a building are noted if access was not obtained.
4.0 ASBESTOS SURVEY
The ACM inspection was performed in accordance with the following regulations for asbestos.
National Emission Standards for Hazardous Air Pollutants (NESHAP), U.S.
Environmental Protection Agency’s (USEPA) requirements for implementation of the Asbestos Hazard Emergency Response Act (AHERA) and the Asbestos School Hazard Abatement Reauthorization Act (ASHARA).
Mr. Robert Provost, Kimberley Marshall, Robert A. Sanders, and Andrew Strong carried out the asbestos survey on the 9th of November 2020. The work was performed under the supervision of Jose J. Sosa, PE, CIH, LAC. Appropriate certification documents are contained in Appendix D of this report.
4.1 ACM Survey Findings: Building 135
The AAC asbestos inspectors performed a visual inspection of all accessible spaces in the building including the exterior to identify those building materials which the EPA has classified as suspect materials that may contain asbestos fibers in their composition matrix. Each material is given a homogenous area designation, a homogeneous area is defined as an area of surfacing, thermal system insulation (TSI), or a miscellaneous building material that is uniform in color or texture and applied on the same date. Nine (9) homogeneous areas (HA’s) of suspect ACM were identified during the visual inspection of Building 109. None of the building materials tested contained asbestos in excess of the regulatory threshold of 1%.
4.2 Asbestos Survey Protocol
Samples were given a unique numeric identification (i.e. 135-1a, 135-1B, etc.). The first three digits corresponding to the building number followed by a number starting with “1” increasing sequentially with the last number representing the total number of homogenous areas identified within the structure. The alphabetical listing indicates the samples collected within a homogeneous sampling area, starting with letter “A” and continuing in alphabetical order. Each sample location was identified on the sample location drawings attached within this document.
Samples of building materials such as vinyl floor tile and associated mastic are considered a multi-layer sample. When analyzed results are reported for each individual layer, thus a sample ID can appear twice showing the multi-layered sample. The laboratory uses L1 and L2 to report and differentiate each layer.
The technique used for sampling the suspect materials was designed to minimize possible fiber release and in turn possible contamination of surround areas. All representative “suspect” materials sampled, were collected in accordance with the EPA’s AHERA and “Guidance for controlling Asbestos Containing Material in Buildings” (EPA 560 / 6-85-024, June 1985).
The sampling procedures of surfacing suspect materials according to AHERA, are known as the 3-5-7 Rule. It is based on square footage of the suspect material present. AHERA recommends up to 1,000 square feet area of a suspect material that a minimum of three samples be collected, quantities between 1,001-5,000 square feet a minimum of five samples is recommended to be collected, and for material greater than 5,000 square feet, a minimum of seven samples are required to be collected. For miscellaneous suspected materials, the AHERA requirements state to collect samples but does not include a specified amount. For miscellaneous suspect materials, the minimum required number of samples is two. The inspector randomly selects rooms in which samples are to be collected, therefore collecting samples from each room is not recommended nor required by federal guidelines.
Suspect materials were wet with an amended soapy water mixture. AAC personnel utilized PPE as deemed appropriate for each sampling event. AAC personnel utilized wet methods while collecting bulk samples.
A representative sample of the material was collected and placed in a labeled airtight bag.
A chain of custody form was completed for all bulk samples collected and shipped to AmeriSci Richmond, Inc. for analysis using Polarized Light Microscopy (PLM). AmeriSci Richmond, Inc. Utilizes dispersion staining techniques according to US EPA method 600 / M4-82-020 incorporating visual estimates of identified material percentages. Once one sample comes back as positive then the entire HA is considered positive, and analysis of additional samples is not required.
During the sampling activities, each suspect ACM was touched by the inspector to determine its friability and observed to determine the physical condition of the material. A friable material is defined as a material that can be crumbled or reduced to powder by hand pressure. Friability of a material directly relates to a potential of the ACM to release airborne fibers. The more friable the ACM the more likely asbestos fibers will be released.
The inspector assessed the suspect ACM according to their physical conditions.
Joint compound associated with gypsum wallboard system will be evaluated to determine whether the material should be classified as “joint compound” or “Skim coat” per EPA’s NESHAP clarification letter published in the Federal Register on January 5th, 1994.
The AAC inspectors split the bulk samples every 20th sample collected. The QA/QC samples were sent to the laboratory under a separate chain of custody from the original building materials sampled. The samples were analyzed by a different PLM analyst in order to compare the original sample results to the QC results. Table 3 contains the QC samples for the specified building. The PLM results for all QC samples analyzed can be found in the attached Quality Control (QC) Sample Results report.
4.3 Regulatory Review
NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. NESHAP requires the identification and classification of existing ACM according to friability prior to demolition or renovation activity.
Under NESHAP, asbestos-containing building materials are classified as:
1. Friable ACM, or
2. Category I Non-Friable ACM, or
3. Category II Non-Friable ACM.
Friable materials are those that, when dry, may be crumbled, pulverized, or reduced to powder by hand pressure.
Category I Non-Friable ACM includes packings, gaskets, resilient floor coverings, mastic or asphalt roofing products containing more than 1% asbestos.
Category II Non-Friable ACM are any materials other than Category I Non-Friable ACM that contain more than 1% Asbestos.
Under NESHAP, Regulated Asbestos-Containing Materials (RACM) are classified as:
1. Friable ACM,
2. Category I Non-Friable ACM that is in poor condition and/or has become friable,
3. Category I Non-Friable ACM that will or has been subjected to sanding, grinding, cutting, or abrading
4. Category II Non-Friable ACM that has a high probability of becoming or has become crumbled, pulverized or reduced to powder by the forces expected to act upon the material in the course of renovation or demolition operations.
According to NESHAP, RACM must be removed prior to renovation or demolition activities that will disturb the materials. Removal of the ACM or RACM must be conducted by a State of New Mexico licenses asbestos abatement contractor, in compliance with New Mexico regulations. In addition, third party air monitoring should be performed during and following the abatement.
The Occupational Safety and Health Administration (OSHA) Asbestos Standard for Construction (29 CFR 1926.1101) regulates employee workplace exposure to asbestos.
The OSHA standard has two Permissible Exposure Limits (PEL) that require employee expose to airborne asbestos fibers be maintained below 0.1 asbestos fibers per cubic centimeter of air (0.1 f/cc) for an 8-hour Time-Weighted Average (8-Hr. TWA) and 1.0 f/cc for a 30-minute TWA (Excursion Limit).
The OSHA standard classifies construction and maintenance activities that could disturb ACM and specifies work practices and precautions that employers must follow when engaged in each class of regulated work. The OSHA classes are described below.
• Class I Asbestos Work means activities involving the removal of TSI and Surfacing ACM and PACM.
• Class II Asbestos Work means activities involving the removal of ACM which is not thermal system insulation or surfacing material. This includes, but is not limited to, the removal of asbestos-containing wallboard, floor tile and sheeting, roofing and siding shingles, and construction mastics.
• Class III Asbestos Work means repair and maintenance operations, where “ACM”, including TSI and surfacing ACM and PACM, is likely to be disturbed.
• Class IV Asbestos Work means maintenance and custodial activities during which employees contact but do not disturb ACM and PACM and activities to clean up dust, waste and debris resulting from Class I, II, and III activities
The Air Quality Bureau (ABQ) is the agency in New Mexico with the oversight responsibility of the asbestos program. The AQB follows the National Emission Standards for Hazardous Air Pollutants (NESHAP). The New Mexico State Legislature adopted the NESHAP regulations (20 NMAC 2.78) for asbestos control in New Mexico statewide.
Albuquerque- Bernalillo County has additional regulation 20.11.20.22 NMAC.
20.11.20.22 Demolition and Renovation Activities; Fugitive Dust Control Construction Permit and Asbestos Notification Requirements. The Demolition and Renovation must also comply with federal standards incorporated in 20.11.64 NMAC, Emission Standards for Hazardous Air Pollutants for Stationary Sources.
5.0 CONCLUSIONS
Based on the analytical results of the samples collected from Building 135, asbestos fibers in the building materials were reported to be below the regulatory threshold of 1%.
Building components and/or finishes in building 135 can be treated as Non-Asbestos Containing Materials.
6.0 RECOMMENDATIONS
Construction and demolition (C&D) debris generated during renovations or demolition of building 135 should be treated as C&D waste. Disposal of the C&D waste should be at a C&D landfill.
Elbows not tested throughout the college in buildings built in 1971 should be sampled and analyzed for asbestos or treated as asbestos containing if the elbows are to be removed or disturbed during renovations or demolition of the mechanical system.
7.0 TABLES AND RESULTS
Table 1 in this section contains the sampling inventory of all identified suspect materials within the building.
Table 2 is the PLM results of the QC’s taken throughout the building.
PLM Lab Results SIPI Super Project
Project Number: P20010-E1503
Sample ID Analyst Description of Material Sample Material / Room
Number
HA
Asbestos Present?
(Y%/N)
135- 1A-L1 White/Blue, Heterogeneous, Non-
Fibrous, Floor Tile 12"x12" FT White & Mastic;
1 NAD
135- 1A-L2 Yellow, Heterogeneous, Non-
Fibrous, Mastic 12"x12" FT White & Mastic;
1 NAD
135- 1B-L1 White/Blue, Heterogeneous, Non-
Fibrous, Floor Tile 12"x12" FT White & Mastic;
1 NAD
135- 1B-L2 Yellow, Heterogeneous, Non-
Fibrous, Mastic 12"x12" FT White & Mastic;
1 NAD
135- 1C-L1 White/Blue, Heterogeneous, Non-
Fibrous, Floor Tile 12"x12" FT White & Mastic;
1 NAD
135- 1C-L2 Yellow, Heterogeneous, Non-
Fibrous, Mastic 12"x12" FT White & Mastic;
1 NAD
135- 1D White/Blue, Heterogeneous, Non-
Fibrous, Floor Tile 12"x12" FT White & Mastic;
1 NAD
135- 1E-L1 White/Blue, Heterogeneous, Non-
Fibrous, Floor Tile 12"x12" FT White & Mastic;
1 NAD
135- 1E-L2 Yellow, Heterogeneous, Non-
Fibrous, Mastic 12"x12" FT White & Mastic;
1 NAD
135- 2A White, Heterogeneous, Non-
Fibrous, Wrap Pipe Jacket; 120 2 NAD
135- 2B White, Heterogeneous, Non-
Fibrous, Wrap Pipe Jacket; 120 2 NAD
135- 2C White, Heterogeneous, Non-
Fibrous, Wrap Pipe Jacket; 124 2 NAD
135- 3A-L1 White, Heterogeneous, Non-
Fibrous, Drywall Drywall; 125 3 NAD
135- 3A-L2 White, Heterogeneous, Non- Fibrous, Textured Material
Drywall; 125 3 NAD
135- 3B-L1 White, Heterogeneous, Non-
Fibrous, Drywall Drywall; 120 3 NAD
135- 3B-L2 White, Heterogeneous, Non- Fibrous, Textured Material
Drywall; 120 3 NAD
135- 3C-L1 White, Heterogeneous, Non-
Fibrous, Drywall Drywall; 121 3 NAD
135- 3C-L2 White, Heterogeneous, Non- Fibrous, Textured Material
Drywall; 121 3 NAD
135- 3D-L1 White, Heterogeneous, Non-
Fibrous, Drywall Drywall; 112 3 NAD
135- 3D-L2 White, Heterogeneous, Non- Fibrous, Textured Material
Drywall; 112 3 NAD
135- 3E-L1 White, Heterogeneous, Non-
Fibrous, Drywall Drywall; 107 3 NAD
Table 1 - Sampling Inventory of Suspect Materials in Building 135
Project Number: P20010-E1503
Sample ID Analyst Description of Material Sample Material / Room
Number
HA
Asbestos Present?
(Y%/N)
Table 1 - Sampling Inventory of Suspect Materials in Building 135
135- 3E-L2 White, Heterogeneous, Non- Fibrous, Textured Material
Drywall; 107 3 NAD
135- 3F White, Heterogeneous, Non- Fibrous, Textured Material
Drywall; 110 3 NAD
135- 3G-L1 White, Heterogeneous, Non-
Fibrous, Drywall Drywall; 125 3 NAD
135- 3G-L2 White, Heterogeneous, Non- Fibrous, Textured Material
Drywall; 125 3 NAD
135- 4A White/Gray, Heterogeneous, Non-
Fibrous, Ceiling Tile CT 2 x 4 Speckled; 110 4 NAD
135- 4B White/Gray, Heterogeneous, Non-
Fibrous, Ceiling Tile CT 2 x 4 Speckled; 125 4 NAD
135- 4C White/Gray, Heterogeneous, Non-
Fibrous, Ceiling Tile CT 2 x 4 Speckled; 105 4 NAD
135- 4D White/Gray, Heterogeneous, Non-
Fibrous, Ceiling Tile CT 2 x 4 Speckled; 124 4 NAD
135- 4E White/Gray, Heterogeneous, Non-
Fibrous, Ceiling Tile CT 2 x 4 Speckled; 114 4 NAD
135- 5A White/Gray, Heterogeneous, Non-
Fibrous, Ceiling Tile CT 2 x 4 Speckled; 120 5 NAD
135- 5B White/Gray, Heterogeneous, Non-
Fibrous, Ceiling Tile CT 2 x 4 Speckled; 120 5 NAD
Project Number: P20010-E1503
Sample ID Analyst Description of Material Sample Material / Room
Number
HA
Asbestos Present?
(Y%/N)
Table 1 - Sampling Inventory of Suspect Materials in Building 135
135- 5C White/Gray, Heterogeneous, Non-
Fibrous, Ceiling Tile CT 2 x 4 Speckled; 120 5 NAD
135- 7A Cream, Heterogeneous, Non-
Fibrous, Mastic Cove Base Mastic; 124 7 NAD
135- 7B Cream, Heterogeneous, Non-
Fibrous, Mastic Cove Base Mastic; 104 7 NAD
135- 7C Cream, Heterogeneous, Non-
Fibrous, Mastic Cove Base Mastic; 112 7 NAD
135- 8A Gray, Heterogeneous, Non-Fibrous, Vapor Barrier Sink Vapor Barrier; 110 8 NAD
135- 8B Gray, Heterogeneous, Non-Fibrous, Vapor Barrier Sink Vapor Barrier; 113 8 NAD
135- 9A Pink, Heterogeneous, Non-Fibrous, Stucco Exterior Stucco; Outside 108 9 NAD
135- 9B Pink, Heterogeneous, Non-Fibrous, Stucco Exterior Stucco; Outside 110 9 NAD
135- 9C Pink, Heterogeneous, Non-Fibrous, Stucco Exterior Stucco; Outside 113 9 NAD
135- 9D Pink, Heterogeneous, Non-Fibrous, Stucco Exterior Stucco; Outside 129 9 NAD
135- 9E Pink, Heterogeneous, Non-Fibrous, Stucco Exterior Stucco; Outside 118 9 NAD
NAD = No Asbestos Detected NA/PS = Not Analyzed/Positive Stop NA = Not Analyzed
L1 Denotes Layer 1 of Suspect Material L2 Denotes Layer 2 of Suspect Material
* Additional Samples Taken on January 19th-21st, 2021
Project Number: P20010-E1503
Sample ID Analyst Description of
Material Sample Material / Room
Number
HA
PLM Results (Total % Asbestos Type)
135-4dd Tan, Heterogeneous, Non-fibrous, Bulk Material CT 2x4 QC NAD
NAD = No Asbestos Detected NA/PS = Not Analyzed/Positive Stop NA = Not Analyzed
L1 Denotes Layer 1 of Suspect Material
* Additional Samples Taken on January 19th-21st, L2 Denotes Layer 2 of Suspect Material
Table 2 - QUALITY CONTROL Analytical Results of Bulk Samples Collected from BUILDING 135
Albuquerque, NM
Appendix A Chain of Custody Form & Laboratory Analytical Report
November 21, 2020
Dear Jose Sosa:
ARS Aleut Construction, LLC Attn: Jose Sosa 9800 4th Street N, Suite 200 Saint Petersburg, FL 33702
RE: ARS Aleut Construction, LLC Job Number 120111677 P.O. #P20010-E1503 P20010-E1503; SIPI Super Project; 9169 Coors Blvd NW, Albuquerque, NM 87120 Building 135
AmeriSci Richmond
13635 GENITO ROAD
MIDLOTHIAN, VIRGINIA 23112
TEL: 8047631200 FAX: 8047631800
Enclosed are the results for PLM asbestos analysis of the following ARS Aleut Construction, LLC samples received at AmeriSci on Monday, November 16, 2020, for a 5 day turnaround:
135-1A, 135-1B, 135-1C, 135-1D, 135-1E, 135-2A, 135-2B, 135-2C, 135-3A, 135-3B, 135-3C, 135-3D, 135-3E, 135-3F, 135-3G, 135-4A, 135-4B, 135-4C, 135-4D, 135-4E, 135-5A, 135-5B, 135-5C, 135-7A, 135-7B, 135-7C, 135-8A, 135-8B, 135-9A, 135-9B, 135-9C, 135-9D, 135-9E
The 33 samples contained in zip lock bag were shipped to AmeriSci via Fed Ex 8149 1844 0801 B. These samples were prepared and analyzed according to EPA PLM Method (EPA 600/R-93/116 Section 2.2). The required analytical information, analysis results, analyst signature and laboratory identification are contained in the PLM Bulk Asbestos Report. If TEM analysis was requested for selected samples the gravimetric reduction data (by Sec 2.3) and TEM Asbestos % (by Sec 2.5) are included in Table 1 along with a summary of Asbestos % by PLM for all samples analyzed.
This report relates ONLY to the sample analysis expressed as % asbestos. AmeriSci assumes no responsibility for customer supplied data such as “sample type”, "location", or “area sampled”. This report must not be used to claim product endorsement by AmeriSci, NVLAP or any agency of the U. S. Government. The National Institute of Standards and Technology accreditation requirements mandate that this report must not be reproduced, except in full, without the written approval of the laboratory. This report may contain specific data not covered by NVLAP or ELAP accreditations, if so identified in relevant footnotes.
Beverly A. Schrage
Sincerely, Senior Analyst | Authorized Signatory
AmeriSci appreciates this opportunity to serve your organization. Please contact us for any further assistance or with any questions.
Boston - Los Angeles - New York - Richmond
AmeriSci Richmond
13635 GENITO ROAD
MIDLOTHIAN, VIRGINIA 23112
TEL: (804) 763-1200 • FAX: (804) 763-1800
11/16/20 AmeriSci Job # 120111677 11/21/20
1 8 P20010-E1503; SIPI Super Project; 9169 Coors Blvd NW, Albuquerque, NM 87120 Building 135
PLM Bulk Asbestos Report Date Received Date Examined
RE:
ofPage
P.O. # ARS Aleut Construction, LLC
9800 4th Street N, Suite 200
Saint Petersburg, FL 33702
Attn: Jose Sosa
Asbestos Present Total % AsbestosClient No. / HGA Lab No.
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-1A 120111677-01L1 NAD 12" FT White & Mastic; 1121
White/Blue, Heterogeneous, Non-Fibrous, Floor Tile
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-1A 120111677-01L2 NAD 12" FT White & Mastic; 1121
Yellow, Heterogeneous, Non-Fibrous, Mastic
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-1B 120111677-02L1 NAD 12" FT White & Mastic; 1251
White/Blue, Heterogeneous, Non-Fibrous, Floor Tile
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-1B 120111677-02L2 NAD 12" FT White & Mastic; 1251
Yellow, Heterogeneous, Non-Fibrous, Mastic
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-1C 120111677-03L1 NAD 12" FT White & Mastic; 1251
White/Blue, Heterogeneous, Non-Fibrous, Floor Tile
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
See Reporting notes on last page
AmeriSci Job #: 120111677 Page 2 of 8
P20010-E1503; SIPI Super Project; 9169 Coors Blvd NW, Albuquerque, NM 87120 Building 135
PLM Bulk Asbestos Report Client Name: ARS Aleut Construction, LLC
Asbestos Present Total % AsbestosClient No. / HGA Lab No.
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-1C 120111677-03L2 NAD 12" FT White & Mastic; 1251
Yellow, Heterogeneous, Non-Fibrous, Mastic
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-1D 120111677-04 NAD 12" FT White & Mastic; 1251
White/Blue, Heterogeneous, Non-Fibrous, Floor Tile
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Comment: insufficient mastic present for analysis
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-1E 120111677-05L1 NAD 12" FT White & Mastic; 1021
White/Blue, Heterogeneous, Non-Fibrous, Floor Tile
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-1E 120111677-05L2 NAD 12" FT White & Mastic; 1021
Yellow, Heterogeneous, Non-Fibrous, Mastic
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-2A 120111677-06 NAD Pipe Jacket; 1202
White, Heterogeneous, Non-Fibrous, Wrap
Cellulose 65 %, Fibrous glass 25 %, Non-fibrous 10 %
(by CVES) by J. Samuel Baird
AmeriSci Job #: 120111677 Page 3 of 8
Albuquerque, NM 87120 Building 135
PLM Bulk Asbestos Report Client Name: ARS Aleut Construction, LLC
Asbestos Present Total % AsbestosClient No. / HGA Lab No.
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-2B 120111677-07 NAD Pipe Jacket; 1202
White, Heterogeneous, Non-Fibrous, Wrap
Cellulose 65 %, Fibrous glass 25 %, Non-fibrous 10 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-2C 120111677-08 NAD Pipe Jacket; 1242
White, Heterogeneous, Non-Fibrous, Wrap
Cellulose 65 %, Fibrous glass 25 %, Non-fibrous 10 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-3A 120111677-09.1 NAD Drywall; 1253
White, Heterogeneous, Non-Fibrous, Drywall
Cellulose 5 %, Fibrous glass 2 %, Non-fibrous 93 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-3A 120111677-09.2 NAD Drywall; 1253
White, Heterogeneous, Non-Fibrous, Textured Material
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-3B 120111677-10.1 NAD Drywall; 1203
White, Heterogeneous, Non-Fibrous, Drywall
Cellulose 5 %, Fibrous glass 2 %, Non-fibrous 93 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-3B 120111677-10.2 NAD Drywall; 1203
White, Heterogeneous, Non-Fibrous, Textured Material
Non-fibrous 100 %
(by CVES) by J. Samuel Baird
AmeriSci Job #: 120111677 Page 4 of 8
Albuquerque, NM 87120 Building 135
PLM Bulk Asbestos Report Client Name: ARS Aleut Construction, LLC
Asbestos Present Total % AsbestosClient No. / HGA Lab No.
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-3C 120111677-11.1 NAD Drywall; 1213
White, Heterogeneous, Non-Fibrous, Drywall
Cellulose 5 %, Fibrous glass 2 %, Non-fibrous 93 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-3C 120111677-11.2 NAD Drywall; 1213
White, Heterogeneous, Non-Fibrous, Textured Material
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-3D 120111677-12.1 NAD Drywall; 1123
White, Heterogeneous, Non-Fibrous, Drywall
Cellulose 5 %, Fibrous glass 2 %, Non-fibrous 93 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-3D 120111677-12.2 NAD Drywall; 1123
White, Heterogeneous, Non-Fibrous, Textured Material
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-3E 120111677-13.1 NAD Drywall; 1073
White, Heterogeneous, Non-Fibrous, Drywall
Cellulose 5 %, Fibrous glass 2 %, Non-fibrous 93 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-3E 120111677-13.2 NAD Drywall; 1073
White, Heterogeneous, Non-Fibrous, Textured Material
Non-fibrous 100 %
(by CVES) by J. Samuel Baird
AmeriSci Job #: 120111677 Page 5 of 8
Albuquerque, NM 87120 Building 135
PLM Bulk Asbestos Report Client Name: ARS Aleut Construction, LLC
Asbestos Present Total % AsbestosClient No. / HGA Lab No.
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-3F 120111677-14 NAD Drywall; 1103
White, Heterogeneous, Non-Fibrous, Textured Material
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Comment: insufficient drywall present for analysis
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-3G 120111677-15.1 NAD Drywall; 1253
White, Heterogeneous, Non-Fibrous, Drywall
Cellulose 5 %, Fibrous glass 2 %, Non-fibrous 93 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-3G 120111677-15.2 NAD Drywall; 1253
White, Heterogeneous, Non-Fibrous, Textured Material
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-4A 120111677-16 NAD CT 2 x 4 Speckled; 1104
White/Gray, Heterogeneous, Non-Fibrous, Ceiling Tile
Cellulose 45 %, Fibrous glass 25 %, Non-fibrous 15 %, Perlite 15 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-4B 120111677-17 NAD CT 2 x 4 Speckled; 1254
White/Gray, Heterogeneous, Non-Fibrous, Ceiling Tile
Cellulose 45 %, Fibrous glass 25 %, Non-fibrous 15 %, Perlite 15 %
(by CVES) by J. Samuel Baird
AmeriSci Job #: 120111677 Page 6 of 8
Albuquerque, NM 87120 Building 135
PLM Bulk Asbestos Report Client Name: ARS Aleut Construction, LLC
Asbestos Present Total % AsbestosClient No. / HGA Lab No.
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-4C 120111677-18 NAD CT 2 x 4 Speckled; 1054
White/Gray, Heterogeneous, Non-Fibrous, Ceiling Tile
Cellulose 45 %, Fibrous glass 25 %, Non-fibrous 15 %, Perlite 15 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-4D 120111677-19 NAD CT 2 x 4 Speckled; 1244
White/Gray, Heterogeneous, Non-Fibrous, Ceiling Tile
Cellulose 45 %, Fibrous glass 25 %, Non-fibrous 15 %, Perlite 15 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-4E 120111677-20 NAD CT 2 x 4 Speckled; 1144
White/Gray, Heterogeneous, Non-Fibrous, Ceiling Tile
Cellulose 45 %, Fibrous glass 25 %, Non-fibrous 15 %, Perlite 15 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-5A 120111677-21 NAD CT 2 x 4 Drywall Tile; 1205
White, Heterogeneous, Non-Fibrous, Ceiling Tile
Cellulose 10 %, Fibrous glass 5 %, Mica 2 %, Non-fibrous 83 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-5B 120111677-22 NAD CT 2 x 4 Drywall Tile; 1205
White, Heterogeneous, Non-Fibrous, Ceiling Tile
Cellulose 10 %, Fibrous glass 5 %, Mica 2 %, Non-fibrous 83 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-5C 120111677-23 NAD CT 2 x 4 Drywall Tile; 1205
White, Heterogeneous, Non-Fibrous, Ceiling Tile
Cellulose 5 %, Fibrous glass 10 %, Mica 2 %, Non-fibrous 83 %
(by CVES) by J. Samuel Baird
AmeriSci Job #: 120111677 Page 7 of 8
Albuquerque, NM 87120 Building 135
PLM Bulk Asbestos Report Client Name: ARS Aleut Construction, LLC
Asbestos Present Total % AsbestosClient No. / HGA Lab No.
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-7A 120111677-24 NAD Cove Base Mastic; 1246
Cream, Heterogeneous, Non-Fibrous, Mastic
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-7B 120111677-25 NAD Cove Base Mastic; 1046
Cream, Heterogeneous, Non-Fibrous, Mastic
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-7C 120111677-26 NAD Cove Base Mastic; 1126
Cream, Heterogeneous, Non-Fibrous, Mastic
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-8A 120111677-27 NAD Sink Vapor Barrier; 1107
Gray, Heterogeneous, Non-Fibrous, Vapor Barrier
Cellulose 50 %, Non-fibrous 50 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-8B 120111677-28 NAD Sink Vapor Barrier; 1137
Gray, Heterogeneous, Non-Fibrous, Vapor Barrier
Cellulose 50 %, Non-fibrous 50 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-9A 120111677-29 NAD Exterior Stucco; Outside 1088
Pink, Heterogeneous, Non-Fibrous, Stucco
Non-fibrous 100 %
(by CVES) by J. Samuel Baird
AmeriSci Job #: 120111677 Page 8 of 8
Albuquerque, NM 87120 Building 135
PLM Bulk Asbestos Report Client Name: ARS Aleut Construction, LLC
Asbestos Present Total % AsbestosClient No. / HGA Lab No.
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-9B 120111677-30 NAD Exterior Stucco; Outside 1108
Pink, Heterogeneous, Non-Fibrous, Stucco
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-9C 120111677-31 NAD Exterior Stucco; Outside 1138
Pink, Heterogeneous, Non-Fibrous, Stucco
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-9D 120111677-32 NAD Exterior Stucco; Outside 1298
Pink, Heterogeneous, Non-Fibrous, Stucco
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Location:
Analyst Description:
Asbestos Types:
Other Material:
No135-9E 120111677-33 NAD Exterior Stucco; Outside 1188
Pink, Heterogeneous, Non-Fibrous, Stucco
Non-fibrous 100 %
(by CVES) by J. Samuel Baird on 11/21/20
Reporting Notes:
*NAD = no asbestos detected, Detection Limit <1%, Reporting Limits: CVES = 1%, 400 Pt Ct = 0.25%, 1000 Pt Ct = 0.1%; "Present" or NVA = "No Visible Asbestos" are observations made during a qualitative analysis; NA = not analyzed; NA/PS = not analyzed / positive stop; PLM Bulk Asbestos Analysis using Meiji, Model MT 6120 microscope, Serial #1900011, by EPA 600/R-93/116 per 40 CFR 763 (NVLAP Lab Code 101904-0) and ELAP PLM Analysis Protocol 198.1 for New York friable samples which includes quantitation of any vermiculite observed (198.6 for NOB samples) or EPA 400 pt ct by EPA 600/M4-82-020 (NYSDOH ELAP Lab # 10984); CA ELAP Lab # 2508; Note: PLM is not consistently reliable in detecting asbestos in floor coverings and similar NOB materials. NAD or Trace results by PLM are inconclusive, TEM is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing in New York State (also see EPA Advisory for floor tile, FR 59, 146, 38970, 8/1/94). NIST Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. This PLM report relates ONLY to the items tested.
Analyzed by: J. Samuel Baird Date: 11/21/2020
Reviewed by: J. Samuel Baird
Albuquerque, NM
Appendix B Positive Sample Photos
Albuquerque, NM
No positive Regulated ACM found in building
Albuquerque, NM
Appendix C Floor Plans
ASBESTOS SURVEY SAMPLE LOCATIONS
BUILDING #135, CHILDCARE CENTER
SOUTHWESTERN INDIAN POLYTECHNIC INSTITUTION
ALBUQUERQUE, NEW MEXICO
0 2.5 5 10
SCALE: 1" = 10'
ASBESTOS CONTAINING MATERIAL
SAMPLE LOCATIONS LEGEND
NON-ASBESTOS CONTAINING MATERIAL
POSITIVE SAMPLE
NEGATIVE SAMPLE
ASBESTOS CONTAINING MATERIAL
NON-ASBESTOS CONTAINING MATERIAL
POSITIVE MULTI-LAYERED SAMPLE
NEGATIVE MULTI-LAYERED SAMPLE
NOTES:
1. BUILDING COMPONENTS CONTAINING
OVER 1% ASBESTOS IN THE MATERIAL
MATRIX ARE CONSIDERED
ASBESTOS-CONTAINING MATERIALS.
2. SAMPLE RESULTS OF BUILDING
MATERIALS EXCEEDING 1% ARE TO BE
CONSIDERED AS ASBESTOS-CONTAINING
MATERIALS.
3. L1/L2 REFERS TO MULTI-LAYERED
SYSTEMS WITHIN THE COMPOSITION
MATRIX OF THE SUSPECT MATERIAL.
Albuquerque, NM
Appendix D Certifications american board of industrial hygiene® organized to improve the practice of industrial hygiene proclaims that
Jose J. Sosa having met all requirements of education, experi~nce and examination, and ongoing maintenance, is hereby certified in the
COMPREHENSIVE PRACTICE
of
INDUSTRIAL HYGIENE
and has the right to use the designations
CERTIFIED INDUSTRIAL HYGIENIST
CIH
Certificate Number 5429CP
Awarded: December 9, 1991
Expiration Date: June 1, 2023
Chief Executive Officei,:A llI
Certificate of Achievement This certificate is awarded to:
Jose J. Sosa In recognition of satisfactory completion of the EPA-approved annual asbestos refresher training provided in accordance with the Model Accreditation Plan (MAP) (40 CFR Part 763, Subpart E, Appendix C) and AHERA of the Toxic Substances Control Act (TSCA) entitled:
Survey & Mechanical (Inspector) Course completion:
Examination Date:
Expiration Date:
Course Hours:
October 30, 2020 October 30, 2020
October 30, 2021
Instructor(s)
Danaya N. BenedettoDanaya N. Benedetto CEO & Training Program Manager
Credential License ID:
24895221
CHC Training Certificate No.
R20-1339-AI-O-FL
CHC Training Environmental Compliance Certification Experts www.chctraining.com 303.412.6360
855.60.CERTIFY
1775 W. 55th Avenue Denver, CO 80221
United States of America
FL Provider No. 0007238 FL Course No. 0006385
Aaron HixAaron Hix
4.0
Verify this Certificate Renew this Certificate
Halsey Beshears, SecretaryRon DeSantis, Governor
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
ASBESTOS LICENSING UNIT
THE ASBESTOS CONSULTANT - ENGINEER HEREIN IS LICENSED UNDER THE
PROVISIONS OF CHAPTER 469, FLORIDA STATUTES
SOSA, JOSE J
Do not alter this document in any form.
10905 BRIDLE PL
LICENSE NUMBER: EA0000055
EXPIRATION DATE: NOVEMBER 30, 2022
This is your license. It is unlawful for anyone other than the licensee to use this document.
TAMPA FL 33626
Always verify licenses online at MyFloridaLicense.com https://www.myfloridalicense.com/LicenseDetail.asp?SID=&id=e8f692c4568dab619e9adcef50c4e0a7
| Bldg 135 Asbestos Survey |
| Asbestos Survey for Building 135 |
| TABLE OF CONTENTS |
| APPENDICES |
| LIST OF ACRONYMS |
| 1.0 EXECUTIVE SUMMARY |
| 1.1 Asbestos-Containing Material Summary |
| 2.0 BUILDING INFORMATION |
| 3.0 LIMITATIONS OF THE SURVEY |
| 4.0 ASBESTOS SURVEY |
| 4.1 ACM Survey Findings: Building 135 |
| 4.2 Asbestos Survey Protocol |
| 4.3 Regulatory Review |
| 5.0 CONCLUSIONS |
| 6.0 RECOMMENDATIONS |
| 7.0 TABLES AND RESULTS |
| Table 1 All Samples |
| Table 2 QC's |
| Appendices |
| Appendix A: COC's & Analytical Report |
| Bldg 135 PLM |
| Appendices |
| Appendix B: Postive Sample Photos |
| Appendix C: Floor Plans |
| SIPI SET 2_2-23-21-BLDG 135 |
| Appendices |
| Appendix D: Certifications |
| Certifications |
| CIH+Lic.+2023 |
| Jose Asbestos Inspector |
| LAC 2022 |
| Provost Robert BIR 09182003AM |
| KMarshall_Asbestos Inspector |
File details come from the government source that posted it. Updated .