14 X 24 STORAGE BUILDING SPECS.docx
DOCX document 20 KB Posted
- Solicitation number
- 00100-0000088871
- Issued by
- Marion County, Indiana
About this file
This is a specifications document for a state and local contract opportunity involving the construction of a utility/storage building for the City of Bloomington, Indiana. The project requires the construction of a 14' x 24' portable utility/storage building with specific structural and material requirements. The building must feature 2x4 wall studs at 16" on center, metal siding and roofing in a color to be determined later, gable vents on the front and rear, an 8' x 7' insulated manual roll-up garage door on the front, and a 36" standard insulated walk-through metal side-access door. The structure must include 2" x 6" treated floor joists at 12" on center with Advantech flooring boards, insulation in the roof, sides, and floor with a minimum R-value between R-1.9 to R-3.3, and an 8-foot sidewall height. All construction must be completed by the primary bidder, with subcontracting of any portion of the construction process resulting in automatic disqualification.
The vendor is responsible for obtaining or paying for all permits associated with transporting, delivering, and placing the building in Bloomington, Indiana, as well as for blocking, leveling, and anchoring the structure. The site will be prepped and rough-leveled by the contracting agency. No windows, entry doors, ramps, or electrical components are required, and the building does not need to meet specific Indiana Building Code requirements, wind-load certifications, or snow-load specifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SOURCING EVENT PAGES 88871.pdf | ||
| EVENT PAGES 88871.pdf | ||
| Notice of Addenum.pdf | ||
| BID INSTRUCTIONS FOR SOURCING EVENT 0000088871.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPECS FOR
14 X 24 UTILITY/STORAGE BUILDING
· Shall be 14’X 24’ utility/portable building
· Construction of the building must be completed by the primary bidder. Subcontracting any portion of the construction process of the building will result in disqualification.
· Shall have 2x4 wall studs (16” On Center)
· Shall have metal siding and roof (color to be detrained later)
· Shall have a gable vent in the front and rear of building
· Shall have a 8’x7’ Insulated Manual Roll-up Garage Door on the front of building
· Shall have an alternate/side access 36” standard insulated walk-through medal door (exact location to be detrained later)
· Shall have 2”x6” treated floor joist (12” On Center)
· Shall have Advantech ¾” flooring boards
· Shall have ½” insulation in the roof, sides and floor
· Minimum required R-value is R-1.9 to 3.3
· Sidewall height and roof style or pitch required: 8 ft sidewall height. No pitch specs.
· No windows, entry doors, ramps or electrical components required.
· Building does not need to meet any particular Indiana Building Code, wind-load or snow-load cortication.
· Vendor needs to include blocking, leveling and anchoring the new structure. Site will be prepped and rough-leveled for the new building
· Vendor is responsible for obtaining or paying for any permits associated with transporting, delivering or placing the building in Bloomington, Indiana.