14-B 04 260505 Clyde C Miller CB Bid Permit Set.pdf
PDF 22 MB Posted
- Solicitation number
- RFP 108-2026
- Issued by
- St. Louis County, Missouri
About this file
This is a Bid/Permit Set for architectural and construction renovation work at Clyde C. Miller Academy, a St. Louis Public Schools facility located at 1000 North Grand Boulevard in Saint Louis, Missouri 63106. The project involves comprehensive renovations to the first floor of the existing building to create new cosmetology and barber instructional spaces, including practical labs, theory labs, and associated support areas. The scope encompasses general construction, mechanical, electrical, and plumbing systems across approximately 12,787 gross square feet. The project serves a mixed-occupancy building classified as Type II-B fully-sprinklered, with 108 occupants in the renovated rooms distributed among barber practical labs, cosmetology practical labs, and three theory labs. The construction documents include detailed floor plans, reflected ceiling plans, demolition plans, furniture and fixture layouts, and comprehensive mechanical, electrical, and plumbing drawings prepared by Cordogan Clark & Associates, Inc. as architect, with ECS - Consulting Engineers providing mechanical, electrical, and plumbing design and Navigate Building Solutions serving as owner's representative.
The project documentation establishes extensive requirements for selective demolition, new partition construction using metal framing systems, and complete finish specifications including porcelain tile flooring, sealed concrete finishes, specialty mineral core flooring, and casework with solid surface countertops. Contractors are required to perform site visits prior to bid submission to verify existing conditions and coordinate work among multiple trades. All work must comply with the 2018 International Building Code, maintain fire-rated assemblies, and accommodate existing building systems while making necessary modifications for new equipment installations including styling stations, barber chairs, manicure and pedicure stations, and associated plumbing and ventilation requirements. The project documents specify that fire sprinkler system installation will be performed by others and establish detailed general conditions, demolition protocols, and coordination requirements between general trades, mechanical, electrical, and plumbing contractors to ensure proper sequencing and integration of all work.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION
G R
AN
D
B
LV
D
BELL AVE
LINDELL BLVD
PAGE BLVD
MLK DR
VICINITY MAPLOCATION MAP
PROJECT NO:
DATE:
C O
P Y
R
IG
H T
A
LL
R
IG
H
TS
R
E S
E R
V E
D
ARCHITECT:
OWNER: CONSULTANTS:
EXISTING CONDITIONS DRAWINGS
5/ 7/
:1
9:
P M
254017 05/04/2026
BID/ PERMIT SET
CLYDE C. MILLER ACADEMY COSMETOLOGY/BARBER SCHOOL RENOVATIONS
SAINT LOUIS PUBLIC SCHOOLS
SAINT LOUIS PUBLIC
SCHOOLS
CORDOGAN CLARK &
ASSOCIATES, INC
3001 LOCUST STREET
SECOND FLOOR
SAINT LOUIS, MISSOURI 63103
(314) 421-3542
MECHANICAL, ELECTRICAL & PLUMBING OWNER'S REPRESENTATIVE:
ECS - CONSULTING
ENGINEERS
14500 SOUTH OUTER FORTY ROAD,
SUITE 108
TOWN & COUNTRY, MISSOURI 63017
(314) 370-0478
801 NORTH 11th STREET
SAINT LOUIS, MISSOURI 63101
(314) 231-3720
NAVIGATE BUILDING
SOLUTIONS
1000 NORTH GRAND BOULEVARD
SAINT LOUIS, MISSOURI 63106
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2019017440
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2018042187
8419 MANCHESTER ROAD
BRENTWOOD, MISSOURI 63144
(314) 713-6205
PROJECT LOCATION
G R
AN
D
B
LV
D
BELL AVE
JO
S
E P
H
IN
E B
AK
E
R B
LV
D
SHEET LIST
1.0 - GENERAL
G0.00 COVER SHEET
G1.01 GENERAL NOTES, ABBREVIATIONS & SYMBOLS LEGEND
G1.02 OVERALL FIRST FLOOR PLAN - SCOPE OF WORK
G1.03 CODE COMPLIANCE
G1.04 FIRST FLOOR LIFE SAFETY PLAN - PRACTICAL LABS
G1.05 FIRST FLOOR LIFE SAFETY PLAN - THEORY LABS
1.1 - DEMOLITION
AD1.01 ENLARGED FIRST FLOOR DEMOLITION PLAN - FUTURE PRACTICAL LABS
AD1.02 ENLARGED FIRST FLOOR DEMOLITION PLAN - FUTURE THEORY LABS
AD3.01 ENLARGED FIRST FLOOR RCP DEMOLITION PLAN - FUTURE PRACTICAL LABS
AD3.02 ENLARGED FIRST FLOOR RCP DEMOLITION PLAN - FUTURE THEORY LABS
2 - ARCHITECTURAL
A1.01 FIRST FLOOR RENOVATED FLOOR PLAN - PRACTICAL LABS
A1.02 FIRST FLOOR RENOVATED FLOOR PLAN - THEORY LABS
A3.01 FIRST FLOOR REFLECTED CEILING PLAN - PRACTICAL LABS
A3.02 FIRST FLOOR REFLECTED CEILING PLAN - THEORY LABS
A5.01 ELEVATIONS, DETAILS & SCHEDULES
A10.01 FINISH SPECIFICATIONS, SCHEDULES, NOTES & DETAILS
A11.01 FIRST FLOOR FURNITURE & FIXTURES PLAN - PRACTICAL LABS
A11.02 FIRST FLOOR FURNITURE & FIXTURES PLAN - THEORY LABS
05 - MECHANICAL
M2.01 FIRST FLOOR RENOVATED PLAN - PRACTICAL LABS - MECHANICAL
M2.02 FIRST FLOOR RENOVATED PLAN - THEORY LABS - MECHANICAL
06A - ELECTRICAL DEMO
ED1.01 FIRST FLOOR DEMO RCP - FUTURE PRACTICAL LABS - ELECTRICAL
ED1.02 FIRST FLOOR DEMO RCP - FUTURE THEORY LABS - ELECTRICAL
06B - ELECTRICAL
E2.01 FIRST FLOOR RENOVATED PLAN - PRACTICAL LABS - ELECTRICAL
E2.02 FIRST FLOOR RENOVATED PLAN - THEORY LABS - ELECTRICAL
E2.03 FIRST FLOOR RENOVATED RCP - PRACTICAL LABS - ELECTRICAL
E2.04 FIRST FLOOR RENOVATED RCP - THEORY LABS - ELECTRICAL
07A - PLUMBING & FP DEMO
PFD1.01 FIRST FLOOR DEMO PLAN - FUTURE PRACTICAL LABS - PLUMBING & FIRE PRTECTION
PFD1.02 FIRST FLOOR DEMO PLAN - FUTURE THEORY LABS - PLUMBING & FIRE PROTECTION
07B - PLUMBING & FP
PF2.01 UNDER FIRST FLOOR RENO PLAN - PRACTICAL LABS - PLUMBING & FIRE PROTECTION
PF2.02 UNDER FIRST FLOOR RENO PLAN - THEORY LABS - PLUMBING & FIRE PROTECTION
PF2.03 FIRST FLOOR RENOVATED PLAN - PRACTICAL LABS - PLUMBING & FIRE PROTECTION
PF2.04 FIRST FLOOR RENOVATED PLAN - THEORY LABS - PLUMBING & FIRE PROTECTION
PF3.01 SCHEDULES & DETAILS - PLUMBING & FIRE PROTECTION
cpauley Image cpauley Image
SHEET NUMBER
ROOM NAME (TOP)
ROOM NUMBER (BOTTOM)
Room name
A210
A101
SIM
A101
SIM
A2
A101
SIM
INTERIOR ELEVATION
ELEVATION No. (OUTSIDE), SHEET No. (CENTER)
DETAIL REFERENCE
DETAIL No. (TOP), SHEET No. (BOTTOM)
A102
0 BUILDING COLUMN GRID LINE
C1 PLAN KEYNOTES (SEE PLAN SHEET)
DOOR TAG
1 WINDOW TAG
PARTITION TYPE
SPOT ELEVATION - Target Filled (Relativel)
REVISION CLOUD AND TAG
NORTH ARROW
SECTION REFERENCE
SECTION No. (TOP), SHEET No. (BOTTOM)
WALL SECTION REFERENCE
SECTION No. (TOP), SHEET No. (BOTTOM)
A2.01
DISCIPLINE
SERIES
DRAWING OR FLOOR
PLAN / ELEVATION / DETAIL /
SECTION TITLE
DIMENSION STRING
A1011 1
CURTAIN WALL TAGSF03
SPOT ELEVATION - Crosshair (Project)
SYMBOLS LEGEND:
X' - X''
ACP ALUMINUM COMPOSITE PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES
ACT
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING
JURISDICTION
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECT
BD BOARD
BOT BOTTOM
BRG BEARING
BS BOTH SIDES
BSMT BASEMENT
BUR BUILT-UP ROOFING
CAB CABINET
CFCI CONTRACTOR-
FURNISHED/CONTRACTOR-
INSTALLED
CFOI CONTRACTOR-
FURNISHED/OWNER-
INSTALLED
CG CORNER GUARD
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CORR CORRIDOR
CPT CARPET
CT CERAMIC TILE
CTR CENTER
dB DECIBEL
DBL DOUBLE
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DISP DISPENSER
DR DOOR
DS DOWNSPOUT
E EAST
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC
ELEV ELEVATOR
EP EPOXY PAINT
EPDM ETHYLENE PROPYLENE DIENE
MONOMER (EPDM)
ROOFING
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
ABBREVIATIONS:
OPP OPPOSITE
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PERF PERFORATED
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PN PANEL
PR PAIR
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT
PVC POLYVINYL CHLORIDE (PVC)
ROOFING
QT QUARRY TILE
QTY QUANTITY
RB RUBBER BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFERENCE
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNIT
S SOUTH
SBS STYRENE BUTADIENE STYRENE
(SBS) MODIFIED BITUMINOUS
PROTECTED MEMBRANE ROOFING
SECT SECTION
SF SQUARE FOOT (FEET)
SGL SINGLE
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
STA STATION
STD STANDARD
STOR STORAGE
SYS SYSTEM
T TREAD
T&G TONGUE AND GROOVE
TEMP TEMPORARY
TPO THERMOPLASTIC POLYOLEFIN
(TPO) ROOFING
TV TELEVISION
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDW WINDOW
WF WIDE FLANGE
WM WIRE MESH
EXH EXHAUST
EXP EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FP FIREPROOF
FT FEET
FTG FOOTING
FUT FUTURE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GL GLASS
GYP GYPSUM
HB HOSE BIBB
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
JAN JANITOR
LAB LABORATORY
LAV LAVATORY
LH LEFT HAND
LT LIGHT
LVT LUXURY VINYL TILE
MAX MAXIMUM
MECH MECHANICAL
MFG MANUFACTURING
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTL METAL
N NORTH
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER-FURNISHED / CONTRACTOR
INSTALLED
OFOI OWNER-FURNISHED/OWNER-
INSTALLED
NOTES:
GENERAL CONDITIONS:
1. ALL CONTRACTORS SHALL BE RESPONSIBLE TO INSTALL ALL ITEMS SPECIFIED USING CONSTRUCTION THAT WILL PROTECT AT ALL TIMES, PROPERTY AND PREVENT BODILY INJURY AND/ OR DEATH. SPECIAL ATTENTION AND PRECAUTION SHALL BE PAID BY THE CONTRACTORS IN SELECTING THE SAFEST METHODS OR MEANS FOR THE INSTALLATION.
2. THE ARCHITECT/ ENGINEER HAS NO CONTRACTUAL DUTY TO CONTROL THE SAFEST METHODS OR MEANS OF THE WORK, JOB SITE RESPONSIBILITIES, SUPERVISION OR TO SUPERVISE SAFETY AND SHALL NOT VOLUNTARILY ASSUME ANY SUCH DUTY OR
RESPONSIBILITY.
3. ALL WORK SHALL BE EXECUTED IN A WORKMAN LIKE MANNER AND IN STRICT ACCORDANCE WITH FEDERAL, STATE AND LOCAL CODES AND ORDINANCES AND ALL AUTHORITIES HAVING JURISDICTION AND ACCEPTED BY THE ARCHITECT AND LEFT IN
PERFECT OPERATING CONDITION.
4. ALL CONTRACTORS SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS PRIOR TO SUBMITTING THE
FINAL BID. IF THERE ARE ANY DISCREPANCIES, NOTIFY THE ARCHITECT AT ONCE.
5. ALL CONTRACTORS SHALL CAREFULLY REVIEW THE DRAWINGS AND OTHER CONTRACT DOCUMENTS PRIOR TO SUBMITTING THE FINAL BID. IF THERE ARE ANY DISCREPANCIES, EACH CONTRACTOR SHALL NOTIFY THE ARCHITECT AT ONCE.
6. ALL WORK SHALL BE PERFORMED IN A WORKMAN LIKE MANNER. EACH CONTRACTOR SHALL INCLUDE LABOR, MATERIALS, TOOLS, EQUIPMENT, ETC., FOR THE COMPLETE CONSTRUCTION OF WORK INDICATED AND SPECIFIED BY THE DRAWINGS AND SPECIFICATION. MATERIALS AS SPECIFIED ON DRAWINGS SHALL BE USED. SUBSTITUTIONS OF MATERIALS WILL NOT BE ALLOWED WITHOUT THE WRITTEN CONSENT OF THE OWNER. CONTRACTOR SHALL AMEND AND MAKE GOOD AT THEIR OWN COST, ANY DEFECTS OR OTHER FAULTS IN THEIR WORKMANSHIP AND/ OR MATERIAL. CONTRACTOR IS TO CLEAN UP DEBRIS
INSIDE AND OUTSIDE THE BUILDING SITE WHICH HAS BEEN CAUSED BY THEIR WORK.
7. NON-BEARING PARTITIONS ARE TO BE LAID OUT SO THAT STOCK COMPONENTS WILL FIT PROPORTIONATE WITHIN INDICATED DIMENSIONS. THE GENERAL TRADES CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE PROCEEDING WITH WORK AND NOTIFY ARCHITECT AT ONCE OF ANY DISCREPANCIES PRIOR TO COMMENCING WORK.
8. PLUMBING SCHEMATIC DRAWINGS, HVAC DRAWINGS, SEWER MAINS, ELECTRICAL OUTLETS, SWITCHES, LIGHT LOCATIONS FOR ROUTING ALL PLUMBING, MECHANICAL AND ELECTRICAL WORK IS TO BE COORDINATED BETWEEN THE TRADES AFFECTED BY THE WORK AS PART OF THEIR INSTALLATION LAYOUT. NO PLUMBING, MECHANICAL OR ELECTRICAL INFORMATION IS TO BE SCALED FROM THE DRAWINGS. ON-SITE VERIFICATION OF ALL DIMENSIONS AND CONDITIONS SHALL BE THE RESPONSIBILITY
OF EACH CONTRACTOR.
9. DO NOT SCALE DRAWINGS.
GENERAL CONSTRUCTION NOTES:
1. PROJECT COORDINATOR SHALL PROVIDE A LOGISTICS PLAN TO THE ARCHITECT AND OWNER FOR REVIEW AND APPROVAL PRIOR TO COMMENCING WORK. THE LOGISTICS PLAN IS TO INCLUDE ALL ROUTING OF VEHICLES, EQUIPMENT, DELIVERY LOCATIONS, FENCING, SECURITY MEASURES, ETC. ANY EXISTING CONDITIONS TO REMAIN THAT ARE DAMAGED DUE TO CONSTRUCTION ARE TO BE RESTORED TO THEIR ORIGINAL CONDITION. THIS INCLUDES, BUT IS NOT LIMITED TO, SIDEWALKS, LANDSCAPING, IRRIGATION, ROADS, PARKING LOTS, BUILDING CONSTRUCTION, ETC.
2. EACH CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS AT THE BUILDING SITE AND REPORT ANY DISCREPANCIES TO THE ARCHITECT IN WRITING PRIOR TO PROCEEDING WITH THE WORK. WRITTEN DIMENSIONS
ON DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
3. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR UNLOADING, STORING, INSPECTION FOR DAMAGE WHEN RECEIVED AND LOSS FROM SITE AND/ OR DAMAGE AFTER RECEIPT FOR ALL MATERIALS FURNISHED BY OWNER.
4. NO PRODUCT SUBSTITUTION WILL BE ALLOWED WITHOUT THE WRITTEN APPROVAL OF THE OWNER OR OWNER'S
REPRESENTATIVE.
5. ALL WORK TO BE NEW EXCEPT WHERE INDICATED AS EXISTING.
6. EACH CONTRACTOR SHALL INSURE THAT ALL BUILDING WORK WILL COMPLY WITH APPLICABLE NATIONAL, STATE AND LOCAL
CODES GOVERNING AUTHORITIES AND UNDERWRITER REGULATIONS.
7. ALL OPENINGS AND OTHER PROVISIONS NECESSARY FOR INSTALLATION OF ARCHITECTURAL, PLUMBING, MECHANICAL, FIRE PROTECTION, ELECTRICAL OR OWNER'S APPARATUS AND EQUIPMENT, MUST BE VERIFIED WITH THE SPECIFIC TRADES INVOLVED AND WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION AND MUST BE OF SIZE, LOCATION, CONFIGURATION, ETC., REQUIRED.
8. ALL CONTRACTORS MUST EXERCISE EXTREME CARE SO AS NOT TO DAMAGE EXISTING CONSTRUCTION ITEMS AND SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION
WITH THE WORK.
9. ALL NEW PARTITIONS WHICH ARE TO EXTEND TIGHT UP TO THE FLOOR OR ROOF CONSTRUCTION ABOVE, ARE TO BE CUT TO FIT AROUND BEAMS, JOISTS, DUCTS, CONDUITS, PIPES, HANGERS, ETC. ALL SUCH CUTS SHALL BE ACCURATE AND STRAIGHT
AND BE SEALED WITH MORTAR OR TAPE AND COMPOUND AND MADE AIRTIGHT.
10. AT ALL LOCATIONS WHERE FLOOR SLAB IS TO BE CUT TO PROVIDE FOR NEW FLOOR POWER OR PLUMBING, SLAB IS TO BE
REPAIRED FLUSH WITH AND TO MATCH EXISTING ADJACENT FLOOR SLAB CONSTRUCTION.
GENERAL DEMOLITION NOTES:
1. INTERFERENCE OF DEMOLITION
A. ALL CONTRACTORS: IF THE DEMOLITION CANNOT PROCEED BECAUSE OF UNFORESEEN EXISTING STRUCTURAL OR
MECHANICAL, ETC. CONDITIONS, THE CONTRACTOR SHALL IMMEDIATELY REPORT THE CONDITION TO THE ARCHITECT.
2. FIRE PROTECTION DURING DEMOLITION AND NEW CONSTRUCTION
A. ALL CONTRACTORS: THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ALL FIRE PROTECTION MEASURES AND
EQUIPMENT DURING DEMOLITION AND NEW CONSTRUCTION AT THE DIRECTION OF THE FIRE PREVENTION OFFICER AT
THE FIRE PROTECTION DISTRICT OFFICE.
3. COORDINATION OF DEMOLITION
A. ALL CONTRACTORS SHALL PROCEED WITH THE DEMOLITION IN A LOGICAL ORDER AND SHALL COORDINATE THE DEMOLITION WITH OTHER TRADES. EACH PHASE OF THE DEMOLITION SHALL BE PRECEDED BY INVESTIGATION OF THE AREA FOR REMOVAL, RELOCATION, DISCONNECTION OR REROUTING OF EXISTING ELEMENTS. PRIORITY OF DEMOLITION
SHOULD BE:
a. GENERAL TRADES CONTRACTOR: ARCHITECTURAL
b. HEATING, A/C AND VENTILATION CONTRACTORS: MECHANICAL WORK
c. FIRE PROTECTION CONTRACTOR: FIRE PROTECTION WORK
d. ELECTRICAL CONTRACTOR: ELECTRICAL WORK
e. PLUMBING CONTRACTOR: PLUMBING WORK
GENERAL DEMOLITION NOTES (CONTINUED):
4. SALVAGED ITEMS
A. WHERE INDICATED ON THE DRAWINGS, "SALVAGE", ITEMS MUST BE CAREFULLY REMOVED, CLEANED AND STORED IN SUCH A WAY AS TO PREVENT DAMAGE. TRANSPORT AND STORE ITEMS OFF SITE OR WITHIN THE AREA OF WORK IN A LEGAL MANNER, UNLESS DIRECTED BY OWNER TO TRANSPORT SAID MATERIALS TO OWNER'S STORAGE AREA.
5. REMOVAL OF EXISTING DOORS AND FRAMES
A. GENERAL TRADES CONTRACTOR: DOORS AND FRAMES THAT ARE TO BE REMOVED ARE INDICATED BY DASHED LINES ON
THE DRAWINGS.
B. GENERAL TRADES CONTRACTOR: ANY EXISTING DOORS & FRAMES TO BE REMOVED, TO ALLOW THE OPENING TO BE FILLED AS PER THE NEW CONSTRUCTION DRAWINGS, SHALL BE REMOVED WITH THE ENTIRE FRAME, ANCHORS AND SILLS.
6. EXISTING WALL OR PARTITION DEMOLITION
A. GENERAL TRADES CONTRACTOR: WHEN REMOVING PORTIONS OR COMPLETE INTERIOR WALLS, INVESTIGATION MUST BE MADE TO DETERMINE IF THE WALL IS BEARING STRUCTURAL LOADS. IF IT IS DETERMINED THAT THE WALL IS BEARING, NOTIFY THE ARCHITECT BEFORE PROCEEDING WITH DEMOLITION. IF THE WALL IS NON-BEARING, PROCEED WITH DEMOLITION TAKING CARE THAT INTERACTING WALLS OR REMAINING WALLS ARE CUT CLEAN TO MINIMIZE FILLING AND
PATCHING OF THE REMAINING PARTITION.
B. GENERAL TRADES CONTRACTOR: IF THE REMOVAL OF AN INTERIOR PARTITION DISTURBS THE EXISTING CEILING THAT IS TO REMAIN, CARE MUST BE TAKEN TO REMOVE AS LITTLE OF THE CEILING AS POSSIBLE AND PROTECT THE ADJACENT
CEILING FROM DAMAGE. (UNLESS NOTED OTHERWISE)
C. GENERAL TRADES CONTRACTOR: IF THE PARTITION DEMOLITION INVOLVES DEMOLITION OF THE FLOORING IN THE AREA, CARE IS TO BE TAKEN TO MINIMIZE DAMAGE TO THE EXISTING FLOORING.
D. ELECTRICAL CONTRACTOR: INVESTIGATE ALL EXISTING WIRING IN THE AREAS OF DEMOLITION TO DETERMINE WHICH CIRCUITS CAN BE ABANDONED, AND IF ANY CIRCUITS MUST BE MAINTAINED TO SUPPLY OTHER AREAS. REMOVE ALL WIRING AND CONDUITS TO BE ABANDONED. RELOCATE ALL CIRCUITS TO BE MAINTAINED OR CLEAR NEW CONSTRUCTION.
E. ALL CONTRACTORS: ALL FINISHES SHALL BE PATCHED TO MATCH FROM IMPLEMENTATION OF WORK.
7. PARTIAL REMOVAL OF EXISTING WALLS OR PARTITIONS
A. GENERAL TRADES CONTRACTOR: WHEN REMOVING PART OF A MASONRY WALL OR PARTITION TO ALLOW FOR THE INSTALLATION OF A NEW DOOR, CUTTING OF THE NEW MASONRY OPENING SHOULD BE ACCOMPLISHED IN A MANNER
THAT RESULTS IN AS SMOOTH AN OPENING AS POSSIBLE.
B. GENERAL TRADES CONTRACTOR: PROVIDE TEMPORARY SHORING, BRACING AND OTHER SUPPORT NECESSARY TO PREVENT MOVEMENT, SETTLEMENT, COLLAPSE OR OTHER DAMAGE TO THE STRUCTURE OR ADJACENT WALLS.
8. DEMOLITION OF MECHANICAL/ PLUMBING/ ELECTRICAL SYSTEMS
A. IT WILL BE THE ASSOCIATED CONTRACTOR'S RESPONSIBILITY TO MAINTAIN THE CONDITION OF ALL REMAINING PIPING, CONDUIT, EQUIPMENT, ETC. WITHIN THEIR SCOPE OF WORK DURING DEMOLITION.
B. ALL CONTRACTORS: NOTIFY OWNER PRIOR TO ANY DEMOLITION OF UTILITIES OR SERVICES WHICH MAY AFFECT
REMAINING OCCUPIED AREAS.
C. ALL CONTRACTORS: MAKE NECESSARY MODIFICATIONS AND ADJUSTMENTS TO ALL MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS AND EQUIPMENT, BOTH NEW AND EXISTING, AS MAY BE REQUIRED BY THESE ALTERATIONS AND
ADDITIONS.
D. PLUMBING CONTRACTOR: CAP ALL PLUMBING ABANDONED DURING DEMOLITION EITHER BELOW FINISH FLOOR LEVEL, ABOVE CEILING OR BEHIND FINISH WALL SURFACE. REROUTE PLUMBING THAT IS TO REMAIN IN SERVICE, AS REQUIRED, TO CLEAR NEW CONSTRUCTION.
E. HEATING & A/C, VENTILATION, ELECTRICAL, PLUMBING, AND FIRE PROTECTION CONTRACTORS: DISCONNECT AT SOURCE AND REMOVE EXISTING ELECTRICAL MATERIALS AND EQUIPMENT AND ALL OTHER MECHANICAL/PLUMBING ITEMS WHICH ARE RENDERED OBSOLETE BY THESE ALTERATIONS AND ADDITIONS. THESE ARE THE PROPERTY OF THE OWNER AND SHALL EITHER BE REMOVED FROM THE SITE OR RETURNED TO THE OWNER'S STOCK AT THE DISCRETION OF THE OWNER.
F. HEATING & A/C AND VENTILATION CONTRACTORS: DISCONNECT, REMOVE AND RELOCATE EXISTING MECHANICAL MATERIALS AND EQUIPMENT, AND ALL OTHER MECHANICAL ITEMS WHICH INTERFERE OR ARE INTERFERED WITH, OBSTRUCT OR ARE OBSTRUCTED BY THESE LOCATIONS AS DIRECTED. RECONNECT SUCH ITEMS IN PROPER OPERATING
CONDITION AT NEW LOCATIONS.
G. ALL CONTRACTORS: ALL CUTTING AND PATCHING AS REQUIRED FOR WORK IS TO BE INCLUDED IN ASSOCIATED SCOPE OF WORK. FINISH WORK SHALL BE BY FINISHING CONTRACTOR BUT UNDER THE GENERAL CONTRACTORS CONTRACT.
9. GENERAL ALL CONTRACTORS
A. ALL CONTRACTORS ARE RESPONSIBLE TO VISIT THE SITE TO DETERMINE THE EXTENT OF DEMOLITION AND PATCHING AS
REQUIRED TO INSTALL THEIR PORTION OF WORK.
B. REFER TO ALL DRAWINGS FOR FULL EXTENT OF DEMOLITION WORK. GENERAL TRADES CONTRACTOR TO INSURE ALL WALL OR FLOOR MOUNTED OBJECTS TO BE REMOVED AND EXISTING TO BE PREPARED FOR NEW FINISHES.
C. ALL CONTRACTORS SHALL VISIT AND INSPECT THE EXISTING BUILDING AND SHALL THOROUGHLY FAMILIARIZE THEMSELVES WITH ACTUAL JOB CONDITIONS BEFORE SIGNING CONTRACTS. NO EXTRAS WILL BE ALLOWED FOR WORK
WHICH MIGHT HAVE BEEN REASONABLY FORESEEN BY AN INSPECTION OF THESE PREMISES.
D. WHILE THE SIZE AND LOCATION OF NEW WORK AND EQUIPMENT IN THE EXISTING BUILDING HAS BEEN INDICATED ON THE DRAWINGS AS ACCURATELY AS POSSIBLE, ALL PRIME CONTRACTORS SHALL ADJUST THEIR WORK AS REQUIRED TO AVOID EXISTING DUCTS, PIPES, CONDUITS AND BEAMS NOT SHOWN ON PLANS. ALL CONTRACTORS SHALL ADAPT THEIR WORK
TO MEET ALL ACTUAL CONDITIONS ON THE EXISTING PREMISES.
E. ALL CONTRACTORS SHALL INSPECT THE PREMISES AND MAKE A DETAILED EXAMINATION OF ALL LOCATIONS WHERE NEW WORK IS TO BE INSTALLED AND SHALL EXAMINE EXISTING PIPING, CONDUITS, STRUCTURAL SUPPORTING BEAMS, ETC.
F. ALL CONTRACTORS AFTER INSPECTING THE PREMISES AND THE DRAWINGS SHALL CALL TO THE ATTENTION OF THE ARCHITECT ANY LACK OF ANY NECESSARY SPACE OR CLEARANCE REQUIRED BY THE VARIOUS EQUIPMENT BEFORE CONTRACT IS SIGNED. ALL CONTRACTORS SHALL BE RESPONSIBLE FOR ALL CHANGES NECESSARY IF THEY NEGLECT TO
DO SO.
G. ALL CONTRACTORS ARE TO PROVIDE TEMPORARY MEANS TO KEEP EXISTING BUILDING WEATHER TIGHT DURING
DEMOLITION AND CONSTRUCTION.
H. IF ASBESTOS OR HAZARDOUS MATERIALS ARE FOUND AT THE SITE, CONTACT THE OWNER AND ARCHITECT IMMEDIATELY.
LINE OF ADJACENT WALL
OR PARTITION PER PLAN
(TYP.)
NOTE:
- PROVIDE TRAP INSULATION WHERE TRAP IS EXPOSED.
- SEE INTERIOR ELEVATIONS FOR MIRROR SIZES.
SEE PLAN
5' - 0"CLEAR MIN.
SEE PLAN
5' - 0"CLEAR MIN.
MAX.
1' - 0"
3' - 6"
FROM WALL
39"-41" MAX.
D
IS
P.
H
EI
G
H T
1'
7"MAX.
7"-9"
T/ S
EA
T
"-1
9"
3'
0"
NOTE:
1. FLUSH VALVE TO BE LOCATED ON THE WIDE SIDE OF STALL OR ROOM
2. DIMENSION SHOWN FOR TOILET PAPER DISPENSER IS DISPENSING HEIGHT OF PAPER
1' - 6"
6" 3' - 0"
" T
O
6"
1' - 5"
8" MIN.
6" MAX.
9" M
IN
" M
IN
TO
A
PR
O
N
" M
IN
2'
"M
AX
LINE OF ADJACENT WALL
OR PARTITION PER PLAN
(TYP.)
2'
SEE PLAN
2' - 6" CLR.
1' - 3"MIN.
HAND DRYER
TO
O
PE
R
AT
E
4'
0" M
AX
M E
C H
A N
IS
M
SOAP DISPENSER
BO
TT
O M
O F
3'
4" A
LI
G
N W
MIRROR
3'
4" M
AX
PAPER TOWEL
DISPENSER
D
IS
PE
N
SE
R
4'
0" M
AX
. T
O
FIRE EXTINGUISHER
CABINET
O
PE
R
AT
IN
G
4'
0" M
AX
. T
O
M E
C H
A N
IS
M
SURFACE-MOUNTED FIRE
EXTINGUISHER
O
PE
R
AT
IN
G
4'
0" M
AX
. T
O
M E
C H
A N
IS
M
M
IN
" C
LR
CABINET SHALL NOT PROJECT
MORE THAN 4" FROM WALL.
WHERE EXTINGUISHER
PROJECTS MORE THAN 4" FROM
WALL, PROVIDE WALL OR FLOOR
BAFFLE FOR CANE DETECTION.
AED CABINET
O
PE
R
AT
IN
G
4'
0" M
AX
. T
O
M E
C H
A N
IS
M
CL O
R
A
LL
O P
E R
A B
LE
P
A R
TS
M
IN
1'
6" 3'
5"
M
IR
R O
R
CC JOB NUMBER
DATE
DRAWING TITLE:
COPYRIGHT ©: CORDOGAN CLARK & ASSOCIATES, INC.
CONSULTANTS:
ARCHITECT:
REVISIONS:
5/ 7/
:1
9:
P M
G1.01
254017
05/04/2026
GENERAL NOTES,
ABBREVIATIONS &
SYMBOLS LEGEND
C L
Y D
E C
. M
IL
L E
R A
C A
D E
M Y
C O
S M
E T
O L
O G
Y /B
A R
B E
R S
C H
O O
L R
E N
O V
A T
IO
N
S
N
O R
TH
G
R A
N D
B O
U
LE
V A
R D
S A
IN
T
LO
U
IS
, M
IS
S
O U
R I 6
S A
IN
T
L O
U
IS
P U
B L
IC
S
C H
O O
L S
B
ID
/ P E
R M
IT
S
E T
CORDOGAN CLARK & ASSOCIATES, INC
3001 LOCUST STREET
SECOND FLOOR
SAINT LOUIS, MISSOURI 63103
(314) 421-3542
MECHANICAL, ELECTRICAL & PLUMBING
OWNER'S REPRESENTATIVE:
ECS - CONSULTING ENGINEERS
14500 SOUTH OUTER FORTY ROAD, SUITE 108
TOWN & COUNTRY, MISSOURI 63017
(314) 370-0478
NAVIGATE BUILDING SOLUTIONS
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2019017440
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2018042187
8419 MANCHESTER ROAD
BRENTWOOD, MISSOURI 63144
(314) 713-6205
1/4" = 1'-0"
ACCESSORY MOUNTING HEIGHT LEGEND
# Description Date
E
D
C
B
F
1 2 3 4 4.1 54.91.1
A
A.1
COSMETOLOGY
PRACTICAL LAB
GYM EQUIPMENT
STORAGE
145B
GYM OFFICE
CORRIDOR
146A
SECONDARY
DISPENSERY
STORAGE
CUSTODIAL CLOSET
STORAGE
ELECTRICAL
160A
DATA ROOM
CORRIDOR
146B
UNISEX RESTROOM
161A
DISPENSERY
161B
BARBER PRACTICAL
LAB
CLASSROOM 167
CLASSROOM 167
STORAGE
167A
THEORY LAB 1
CLASSROOM
CUSTODIAL CLOSET
MENS TOILET ROOM
WMNS TOILET ROOM
CLASSROOM
STORAGE
153B
STORAGE
153A
CLASSROOM
STORAGE
152A
CLASSROOM
STORAGE
147A
161B
CORRIDOR
146B
THEORY LAB 2
THEORY LAB 3
DATA CLOSET
165A
NORTH STAIR
ST1
CLOSET
164A
AD1.01
AD1.02
CC JOB NUMBER
DATE
DRAWING TITLE:
COPYRIGHT ©: CORDOGAN CLARK & ASSOCIATES, INC.
CONSULTANTS:
ARCHITECT:
REVISIONS:
5/ 7/
:1
9:
P M
G1.02
254017
05/04/2026
OVERALL FIRST
FLOOR PLAN -
SCOPE OF WORK
C L
Y D
E C
. M
IL
L E
R A
C A
D E
M Y
C O
S M
E T
O L
O G
Y /B
A R
B E
R S
C H
O O
L R
E N
O V
A T
IO
N
S
N
O R
TH
G
R A
N D
B O
U
LE
V A
R D
S A
IN
T
LO
U
IS
, M
IS
S
O U
R I 6
S A
IN
T
L O
U
IS
P U
B L
IC
S
C H
O O
L S
B
ID
/ P E
R M
IT
S
E T
CORDOGAN CLARK & ASSOCIATES, INC
3001 LOCUST STREET
SECOND FLOOR
SAINT LOUIS, MISSOURI 63103
(314) 421-3542
MECHANICAL, ELECTRICAL & PLUMBING
OWNER'S REPRESENTATIVE:
ECS - CONSULTING ENGINEERS
14500 SOUTH OUTER FORTY ROAD, SUITE 108
TOWN & COUNTRY, MISSOURI 63017
(314) 370-0478
NAVIGATE BUILDING SOLUTIONS
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2019017440
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2018042187
8419 MANCHESTER ROAD
BRENTWOOD, MISSOURI 63144
(314) 713-6205
3/16" = 1'-0"
1 OVERALL FIRST FLOOR PLAN SCOPE OF WORK
N
AD3.02
A1.02
A3.02
A11.02
THEORY LABS
AD3.01
A1.01
A3.01
A11.01
PRACTICAL LABS
# Description Date
SCOPE OF WORK
BUILDING A: 2 STORY BUILDING
TOTAL PERIMETER: 700'-2"
PERIMETER OPEN PUBLIC WAY: 657'-9"
2 HOUR FIRE RATED
BUILDING SEPARATION
LEGEND
BUILDING B: PARTIAL 2 STORY BUILDING
TOTAL PERIMETER: 849'-5"
PERIMETER OPEN PUBLIC WAY: 899'-11"
BUILDING C: 1 STORY BUILDING
TOTAL PERIMETER: 469'-10"
PERIMETER OPEN PUBLIC WAY: 433'-6"
BUILDING D: 2 STORY BUILDING
TOTAL PERIMETER: 583'-7"
PERIMETER OPEN PUBLIC WAY: 606'-8"
EXISTING BUILDING - INTERIOR REMODEL
LEVEL 01
MIXED-OCCUPANCY - (A-3) ASSEMBLY, (E) EDUCATIONAL,
(B) BUSINESS, (S-1) STORAGE
TYPE II-B
FULLY-SPRINKLERED
STORIES / HEIGHT = EXISTING UNCHANGED
OCCUPANTS = ±875
NUMBER OF EXITS: 4 (LOWER LEVEL), 12 (FIRST FLOOR) = 16
REQUIRED EXITS = 3
EGRESS WIDTH = 6'-0"
REQUIRED EGRESS WIDTH (.2) = 14'-7"
AREA (FIRST FLOOR) = 12,787 GSF
ALLOWABLE AREA = EXISTING UNCHANGED
EXIT REMOTENESS = EXISTING UNCHANGED
CC JOB NUMBER
DATE
DRAWING TITLE:
COPYRIGHT ©: CORDOGAN CLARK & ASSOCIATES, INC.
CONSULTANTS:
ARCHITECT:
REVISIONS:
5/ 7/
:1
9:
P M
G1.03
254017
05/04/2026
CODE COMPLIANCE
C L
Y D
E C
. M
IL
L E
R A
C A
D E
M Y
C O
S M
E T
O L
O G
Y /B
A R
B E
R S
C H
O O
L R
E N
O V
A T
IO
N
S
N
O R
TH
G
R A
N D
B O
U
LE
V A
R D
S A
IN
T
LO
U
IS
, M
IS
S
O U
R I 6
S A
IN
T
L O
U
IS
P U
B L
IC
S
C H
O O
L S
B
ID
/ P E
R M
IT
S
E T
CORDOGAN CLARK & ASSOCIATES, INC
3001 LOCUST STREET
SECOND FLOOR
SAINT LOUIS, MISSOURI 63103
(314) 421-3542
MECHANICAL, ELECTRICAL & PLUMBING
OWNER'S REPRESENTATIVE:
ECS - CONSULTING ENGINEERS
14500 SOUTH OUTER FORTY ROAD, SUITE 108
TOWN & COUNTRY, MISSOURI 63017
(314) 370-0478
NAVIGATE BUILDING SOLUTIONS
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2019017440
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2018042187
8419 MANCHESTER ROAD
BRENTWOOD, MISSOURI 63144
(314) 713-6205
1" = 40'-0"
1 FIRE FRONTAGE FIRST FLOOR PLAN
# Description Date
GENERAL CODE NOTES
1. NON-OCCUPIABLE CRAWL SPACE NOT SHOWN ON CODE PLANS.
2. FIRE SPRINKLER SYSTEM TO BE INSTALLED BY OTHERS.
3. FIRE EXTINGUISHER CABINETS LOCATED SUCH THAT THE MAX TRAVEL DISTANCE FROM ANY POINT IN THE BUILDING
DOES NOT EXCEED 75-0".
SYMBOL LEGEND
EXISTING PARTITION (NON RATED)
NON RATED PARTITION
NON-OCCUPIABLE
X'-X" MAX EGRESS TRAVEL DISTANCES
ROOM NAME
ROOM NUMBER
OCCUPANCY
XXX SF
X
#OCC
ROOM NAME
ROOM NUMBER
TOTAL NUMBER OF OCCUPANTS
OCCUPANCY CLASSIFICATION
AREA IN SQUARE FEET
USE OF OCCUPANCY
ACCESSORY STORAGE AREA
(300 GROSS/OCC)
EDUCATIONAL, VOCATIONAL ROOM
(50 NET/OCC)
AREA NOT IN SCOPE
FEC FIRE EXTINGUISHER CABINET
EXISTING SMOKE PARTITION
EXISTING TWO HOUR BLDG SEPARATION
EXISTING ONE-HOUR FIRE PARTITION
EXIT DISCHARGE
ACTUAL NUMBER OF OCCUPANTS
EXITING
MAXIMUM CAPACITY TO EXIT
E
D
F
1 2 3 4 4.1 54.91.1
955 SF
BARBER
PRACTICAL LAB
EDUCATION E
131' - 4" P
ATH OF EGRESS TO MAIN CORRIDOR
133' - 6" P
ATH OF EGRESS TO NORTH STAIR EXIT
137' - 9" PATH O
F EG
RESS TO
M
AIN CO
RRIDO
R
140' - 0" PATH O
F EG
RESS TO
NO
RTH STAIR EXIT
1111 SF
COSMETOLOGY
PRACTICAL LAB
EDUCATION E
317 SF
DISPENSARY
161B
STORAGE S-1
C O
M M
O N
P A
TH
O
F E
G R
E S
S
CUSTODIAL CLOSET STORAGE
ELECTRICALDATA ROOM
UNISEX RESTROOM
CLASSROOM
CUSTODIAL CLOSET
MENS TOILET ROOMWMNS TOILET ROOM
CLASSROOM
STORAGE
GYM OFFICE
CORRIDOR
CORRIDOR
FEC
NO CHANGE TO
OCCUPANCY
GYM EQUIPMENT
STORAGE
COMMON PATH OF EGRESS
OCCUPANCY CALCULATIONS PER 2018 IBC
RENOVATED ROOMS
FIRST FLOOR
(GROUP E)
DISPENSARY:
(FORMER PART OF STAFF RESTROOM 161B, WOMENS AND TEACHER RESOURCE ROOM 161)
80 SF / 300 GROSS = 1 OCCUPANT 2 OCC
Accessory Storage area
SECONDARY DISPENSARY:
(FORMER DISPENSARY)
80 SF / 300 GROSS = 1 OCCUPANT 1 OCC
Accessory Storage area
UNISEX RESTROOM:
(FORMER STAFF RESTROOM 161A, MENS)
69 SF = 0 OCCUPANTS 0 OCC
Non Occupiable Space
BARBER PRACTICAL LAB:
(FORMER CLASSROOM 162)
955 SF / 50 NET = 20 OCCUPANTS 20 OCC
Educational, Vocational Room Areas
COSMETOLOGY PRACTICAL LAB:
(FORMER TEACHER RESOURCE ROOM 161)
1111 SF / 50 NET = 23 OCCUPANTS 23 OCC
Educational, Vocational Room Areas
THEORY LAB 1:
(FORMER CLASSROOM 163)
955 SF / 50 NET = 20 OCCUPANTS 21 OCC
Educational, Vocational Room Areas
THEORY LAB 2:
(FORMER CLASSROOM 164)
1006 SF / 50 NET = 21 OCCUPANTS 21 OCC
Educational, Vocational Room Areas
THEORY LAB 3:
(FORMER CLASSROOM 165)
1006 SF / 50 NET = 21 OCCUPANTS 20 OCC
Educational, Vocational Room Areas
RENOVATED ROOM TOTALS 108 OCC
CC JOB NUMBER
DATE
DRAWING TITLE:
COPYRIGHT ©: CORDOGAN CLARK & ASSOCIATES, INC.
CONSULTANTS:
ARCHITECT:
REVISIONS:
5/ 7/
:1
9:
P M
G1.04
254017
05/04/2026
FIRST FLOOR LIFE
SAFETY PLAN -
PRACTICAL LABS
C L
Y D
E C
. M
IL
L E
R A
C A
D E
M Y
C O
S M
E T
O L
O G
Y /B
A R
B E
R S
C H
O O
L R
E N
O V
A T
IO
N
S
N
O R
TH
G
R A
N D
B O
U
LE
V A
R D
S A
IN
T
LO
U
IS
, M
IS
S
O U
R I 6
S A
IN
T
L O
U
IS
P U
B L
IC
S
C H
O O
L S
B
ID
/ P E
R M
IT
S
E T
CORDOGAN CLARK & ASSOCIATES, INC
3001 LOCUST STREET
SECOND FLOOR
SAINT LOUIS, MISSOURI 63103
(314) 421-3542
MECHANICAL, ELECTRICAL & PLUMBING
OWNER'S REPRESENTATIVE:
ECS - CONSULTING ENGINEERS
14500 SOUTH OUTER FORTY ROAD, SUITE 108
TOWN & COUNTRY, MISSOURI 63017
(314) 370-0478
NAVIGATE BUILDING SOLUTIONS
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2019017440
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2018042187
8419 MANCHESTER ROAD
BRENTWOOD, MISSOURI 63144
(314) 713-6205
1/4" = 1'-0"
1 FIRST FLOOR LIFE SAFETY PLAN - PRACTICAL LABS
N
# Description Date
GENERAL CODE NOTES
1. NON-OCCUPIABLE CRAWL SPACE NOT SHOWN ON CODE PLANS.
2. FIRE SPRINKLER SYSTEM TO BE INSTALLED BY OTHERS.
3. FIRE EXTINGUISHER CABINETS LOCATED SUCH THAT THE MAX TRAVEL DISTANCE FROM ANY POINT IN THE BUILDING
DOES NOT EXCEED 75-0".
SYMBOL LEGEND
EXISTING PARTITION (NON RATED)
NON RATED PARTITION
NON-OCCUPIABLE
X'-X" MAX EGRESS TRAVEL DISTANCES
ROOM NAME
ROOM NUMBER
OCCUPANCY
XXX SF
X
#OCC
ROOM NAME
ROOM NUMBER
TOTAL NUMBER OF OCCUPANTS
OCCUPANCY CLASSIFICATION
AREA IN SQUARE FEET
USE OF OCCUPANCY
ACCESSORY STORAGE AREA
(300 GROSS/OCC)
EDUCATIONAL, VOCATIONAL ROOM
(50 NET/OCC)
AREA NOT IN SCOPE
FEC FIRE EXTINGUISHER CABINET
EXISTING SMOKE PARTITION
EXISTING TWO HOUR BLDG SEPARATION
EXISTING ONE-HOUR FIRE PARTITION
EXIT DISCHARGE
ACTUAL NUMBER OF OCCUPANTS
EXITING
MAXIMUM CAPACITY TO EXIT
OCCUPANCY CALCULATIONS PER 2018 IBC
RENOVATED ROOMS
FIRST FLOOR
(GROUP E)
DISPENSARY:
(FORMER PART OF STAFF RESTROOM 161B, WOMENS AND TEACHER RESOURCE ROOM 161)
80 SF / 300 GROSS = 1 OCCUPANT 2 OCC
Accessory Storage area
SECONDARY DISPENSARY:
(FORMER DISPENSARY)
80 SF / 300 GROSS = 1 OCCUPANT 1 OCC
Accessory Storage area
UNISEX RESTROOM:
(FORMER STAFF RESTROOM 161A, MENS)
69 SF = 0 OCCUPANTS 0 OCC
Non Occupiable Space
BARBER PRACTICAL LAB:
(FORMER CLASSROOM 162)
955 SF / 50 NET = 20 OCCUPANTS 20 OCC
Educational, Vocational Room Areas
COSMETOLOGY PRACTICAL LAB:
(FORMER TEACHER RESOURCE ROOM 161)
1111 SF / 50 NET = 23 OCCUPANTS 23 OCC
Educational, Vocational Room Areas
THEORY LAB 1:
(FORMER CLASSROOM 163)
955 SF / 50 NET = 20 OCCUPANTS 21 OCC
Educational, Vocational Room Areas
THEORY LAB 2:
(FORMER CLASSROOM 164)
1006 SF / 50 NET = 21 OCCUPANTS 21 OCC
Educational, Vocational Room Areas
THEORY LAB 3:
(FORMER CLASSROOM 165)
1006 SF / 50 NET = 21 OCCUPANTS 20 OCC
Educational, Vocational Room Areas
RENOVATED ROOM TOTALS 108 OCC
D
C
B
1 2 3 4 4.1 54.91.1
A
A.1
7' -
6" P
ATH O
F EGRESS TO NORTH STAIR EXIT
111' - 6" P
ATH O
F EGRESS TO M
AIN
CORRIDOR
1006 SF
THEORY LAB 2
EDUCATION E
95' - 9" PATH OF EGRESS TO NORTH STAIR EXIT
119' - 0" PATH OF EGRESS TO MAIN CORRIDOR
80 SF
SECONDARY
DISPENSARY
STORAGE S-1
STORAGE
CUSTODIAL CLOSET STORAGE
ELECTRICALDATA ROOM
MENS TOILET ROOMWMNS TOILET ROOM
CLASSROOM 167
CLASSROOM
STORAGE
STORAGE
CLASSROOM
STORAGE
152A
CLASSROOM 167
STORAGE
CORRIDOR
CORRIDOR
FEC
1006 SF
THEORY LAB 1
EDUCATION E
72' - 10" PATH OF EGRESS TO NORTH STAIR EXIT
144' - 5" PATH OF EGRESS TO MAIN CORRIDOR
964 SF
THEORY LAB 3
EDUCATION E
CLOSET
DATA CLOSET
NORTH STAIR
CC JOB NUMBER
DATE
DRAWING TITLE:
COPYRIGHT ©: CORDOGAN CLARK & ASSOCIATES, INC.
CONSULTANTS:
ARCHITECT:
REVISIONS:
5/ 7/
:1
9:
P M
G1.05
254017
05/04/2026
FIRST FLOOR LIFE
SAFETY PLAN -
THEORY LABS
C L
Y D
E C
. M
IL
L E
R A
C A
D E
M Y
C O
S M
E T
O L
O G
Y /B
A R
B E
R S
C H
O O
L R
E N
O V
A T
IO
N
S
N
O R
TH
G
R A
N D
B O
U
LE
V A
R D
S A
IN
T
LO
U
IS
, M
IS
S
O U
R I 6
S A
IN
T
L O
U
IS
P U
B L
IC
S
C H
O O
L S
B
ID
/ P E
R M
IT
S
E T
CORDOGAN CLARK & ASSOCIATES, INC
3001 LOCUST STREET
SECOND FLOOR
SAINT LOUIS, MISSOURI 63103
(314) 421-3542
MECHANICAL, ELECTRICAL & PLUMBING
OWNER'S REPRESENTATIVE:
ECS - CONSULTING ENGINEERS
14500 SOUTH OUTER FORTY ROAD, SUITE 108
TOWN & COUNTRY, MISSOURI 63017
(314) 370-0478
NAVIGATE BUILDING SOLUTIONS
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2019017440
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2018042187
8419 MANCHESTER ROAD
BRENTWOOD, MISSOURI 63144
(314) 713-6205
1/4" = 1'-0"
1 FIRST FLOOR LIFE SAFETY PLAN - THEORY LABS
N
# Description Date
GENERAL DEMOLITION NOTES
1. REFER TO DRAWING G1.01 FOR FULL GENERAL DEMOLITION NOTES WHICH APPLY TO ALL DEMOLITION SHEETS.
2. DEMOLITION SHEET NOTES APPLY TO ALL DEMOLITION SHEETS.
3. EXISTING CONSTRUCTION TO REMAIN IS SHOWN HALF-TONED AND SHADED AS INDICATED IN LEGEND. CONSTRUCTION SCHEDULED FOR DEMOLITION IS SHOWN IN FULL-TONED DASHED LINES AND MAY INCLUDE RED SHADING. THE INTENT OF DEMOLITION IS SHOWN GRAPHICALLY AND NOT ALL ITEMS INDICATED TO BE DEMOLISHED WILL NECESSARILY BE INDIVIDUALLY TAGGED FOR DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION INTENT WHETHER ITEM IS TAGGED
OR NOT.
4. PRIOR TO DEMOLITION, CONTRACTOR SHALL REVIEW ALL NEW WORK AND COORDINATE DEMOLITION REQUIREMENTS TO ACCOMMODATE NEW WORK. THE FULL EXTENT OF DEMOLITION REQUIRED FOR THE NEW WORK MAY NOT BE FULLY DESCRIBED
ON THE DEMOLITION DRAWINGS.
5. THESE DRAWINGS HAVE BEEN DEVELOPED FROM EXISTING INFORMATION, WHICH MAY NOT REFLECT ACTUAL FIELD CONDITIONS. CONTRACTOR SHALL FIELD VERIFY THESE DRAWINGS WITH ALL EXISTING FIELD CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF INCONSISTENCIES WITH ACTUAL CONDITIONS PRIOR TO PROCEEDING WITH CONSTRUCTION.
6. PRIOR TO ANY DEMOLITION, THE CONTRACTOR SHALL VERIFY EXISTING SYSTEMS AND BUILDING SERVICES SERVING OTHER PORTIONS OF THE BUILDING AND COORDINATE ANY REQUIRED RELOCATION WORK WITH THE OWNER. ANY DISRUPTION TO EXISTING BUILDING SERVICES SHALL BE STRICTLY COORDINATED WITH DESIGNATED SCHOOL REPRESENTATIVE PRIOR TO
DISRUPTING ANY EXISTING SERVICE. OBTAIN WRITTEN APPROVAL PRIOR TO PROCEEDING.
7. ALL EXISTING CONSTRUCTION SCHEDULED TO REMAIN SHALL BE PROTECTED DURING DEMOLITION. ANY EXISTING CONSTRUCTION DAMAGED DURING THE WORK SHALL BE REPAIRED OR REPLACED TO MATCH THE ORIGINAL CONDITION AND/OR ADJACENT CONSTRUCTION. ANY REMEDIAL REQUIRED SHALL BE AT NO ADDITIONAL COST TO THE OWNER.
8. ACTIVE PIPES, CONDUITS, AND OTHER UTILITIES OF ALL TYPES, WHETHER SHOWN IN THE CONSTRUCTION DOCUMENTS OR NOT, MUST BE PROTECTED AT ALL TIMES DURING THE CONSTRUCTION OF THE WORK. EXTREME CARE SHALL BE EXERCISED AT ALL TIMES NOT TO DAMAGE ANY SUCH PIPES AND CONDUITS. WHERE DAMAGE OCCURS, CONTRACTOR CAUSING THE DAMAGE SHALL REPAIR SUCH DAMAGE IN A MANNER APPROVED BY THE ARCHITECT AND OWNER, AND AT NO CHANGE IN THE CONTRACT
PRICES OF CONTRACTOR.
9. WHEN REMOVING WALL PARTITIONS REMOVE ALL ELEMENTS ATTACHED TO THE WALL, INCLUDING CONDUIT, WIRING, OUTLETS, SWITCHES, THERMOSTATS, CLOCKS, INTERCOM, PROJECTION SCREENS, TACK BOARDS, MARKER BOARDS, TACK PANELS, TACK STRIPS, FIRE ALARM DEVICES, PLUMBING FIXTURES, PIPES, ETC., UNLESS NOTED OTHERWISE. SEE MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
10. THE CONTRACTOR SHALL CAREFULLY SALVAGE AND STORE EXISTING ITEMS CALLED OUT TO BE RELOCATED/ REINSTALLED.
REPAIR ANY DAMAGE TO ALL EXISTING SURFACES AND ITEMS BEING SALVAGED FOR REUSE/REINSTALL.
11. PATCH & REPAIR ALL HOLES, DAMAGE, ETC. IN EXISTING CONSTRUCTION REMAINING AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE. PATCH & REPAIR WORK SHALL MATCH EXISTING ADJACENT SURFACES & MATERIALS, UNLESS
NOTED OTHERWISE. SEE NEW WORK FOR ADDITIONAL INFORMATION.
12. THE CONTRACTOR SHALL PATCH AND REPAIR MATERIALS AND FINISHES TO MATCH EXISTING ADJACENT AT AREAS OF MEP
DEMOLITION AND INSTALLATION. COORDINATE WITH MEP SHEETS.
DEMOLITION PLAN LEGEND
EXISTING PARTITION
EXISTING SMOKE PARTITION
EXISTING TWO HOUR BUILDING SEPARATION
EXISTING PARTITION TO BE REMOVED
EXISTING WINDOW & FRAME
EXISTING WINDOW TO BE
REMOVED
EXISTING DOOR & FRAME
EXISTING DOOR & FRAME TO BE REMOVED
EXISTING AREA TO BE DEMOLISHED.
VERIFY IN FIELD PRIOR TO DEMOLITION
AREA NOT IN SCOPE
EXISTING ONE-HOUR FIRE PARTITION
EXISTING 2'x4' ACT TILE CEILING & GRID
TO BE REMOVED.
EXISTING 2'x4' TROFFER LIGHTING TO BE
REMOVED (TYP)
REMOVE CABINETRY, COUNTERTOP & SINK.
PREP FOR NEW CABINETS, COUNTERTOP &
SINK.
EXISTING CARPETING TO BE REMOVED.
EXISTING VCT FLOORING TO BE REMOVED.
EXISTING FLOOR TRANSITION STRIP TO BE
REMOVED.
EXISTING VCT FLOORING TO BE REMOVED.
DASHED LINE DENOTES PATCH & REPAIR WALL
AT WALL BASE AND REMOVE EXISTING WALL
BASE. PREPARE FOR NEW WORK.
NOTE: IN WOMENS STAFF RESTROOM, REMOVE
FLOORING AND CAP DRAINS AT FLOOR. SEE
DEMO PLANS.
EXISTING GRAB BARS AND OTHER TOILET
ACCESSORIES TO REMAIN.
E
D
F
1 2 3 4 4.1 54.91.1
CLASSROOM 162
TEACHER RESOURCE
ROOM
MENS STAFF
RESTROOM
WMNS STAFF
RESTROOM
CLASSROOM 162
STORAGE
CORRIDOR
CORRIDOR
GYM
OFFICE
GYM
EQUIPMENT
STORAGE
DATA
ROOM
ELECTRICAL
CUSTODIAL
CLOSET
STORAGE
CLASSROOM 147
WOMENS TOILET
ROOM
CLASSROOM 147
STORAGE
CUSTODIAL
CLOSET
MENS TOILET
ROOM
6 / A D
1.01
/ A
D 1.
7 / AD1.01
/ A
D 1.
DF13
DF4
DF14
DF1
DF8
DF6
DF3
DF2
DF2
DF5
DF9
DF2
DF6
DF2
DF12
DF6
DF13
DF6
DF10
DF15
DF8
DF16
DF17
DF17
EXISTING 2'x4' ACT
TILE CEILING & GRID
TO REMAIN.
EXISTING 2'x4'
TROFFER LIGHTING TO
REMAIN (TYP)
EXISTING VCT FLOORING
TO BR REMOVED
EXISTING WALL &
ELECTRICAL BOX IN
CLOSET TO BE
REMOVED, REFER
TO ELECTRICAL
DRAWINGS.
REMOVE CABINETRY,
COUNTERTOP & SINK. PREP
FOR NEW CABINETS,
COUNTERTOP & SINK.
DOOR TO BE REMOVED IN
ITS ENTIRETY. KEEP
EXISTING DOOR AND FRAME
FOR REUSE. PREPARE FOR
NEW DOOR HARDWARE.
REMOVE RESTROOM
PLACARD AND SAVE FOR
FUTURE USE.
EXISTING VCT FLOORING
TO BE REMOVED.
CC JOB NUMBER
DATE
DRAWING TITLE:
COPYRIGHT ©: CORDOGAN CLARK & ASSOCIATES, INC.
CONSULTANTS:
ARCHITECT:
REVISIONS:
5/ 7/
:1
9:
P M
AD1.01
254017
05/04/2026
ENLARGED FIRST
FLOOR
DEMOLITION PLAN -
FUTURE
PRACTICAL LABS
C L
Y D
E C
. M
IL
L E
R A
C A
D E
M Y
C O
S M
E T
O L
O G
Y /B
A R
B E
R S
C H
O O
L R
E N
O V
A T
IO
N
S
N
O R
TH
G
R A
N D
B O
U
LE
V A
R D
S A
IN
T
LO
U
IS
, M
IS
S
O U
R I 6
S A
IN
T
L O
U
IS
P U
B L
IC
S
C H
O O
L S
B
ID
/ P E
R M
IT
S
E T
CORDOGAN CLARK & ASSOCIATES, INC
3001 LOCUST STREET
SECOND FLOOR
SAINT LOUIS, MISSOURI 63103
(314) 421-3542
MECHANICAL, ELECTRICAL & PLUMBING
OWNER'S REPRESENTATIVE:
ECS - CONSULTING ENGINEERS
14500 SOUTH OUTER FORTY ROAD, SUITE 108
TOWN & COUNTRY, MISSOURI 63017
(314) 370-0478
NAVIGATE BUILDING SOLUTIONS
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2019017440
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2018042187
8419 MANCHESTER ROAD
BRENTWOOD, MISSOURI 63144
(314) 713-6205
DEMOLITION FLOOR PLAN KEYNOTES
DF1 EXISTING CARPETING TO BE REMOVED.
DF2 EXISTING VCT FLOORING TO BE REMOVED.
DF3 EXISTING FLOOR TRANSITION STRIP TO BE REMOVED.
DF4 REMOVE CABINETRY, COUNTERTOP & SINK. PREP FOR NEW CABINETS, COUNTERTOP & SINK.
DF5 EXISTING PLUMBING FIXTURES AND ASSOCIATED TOILET ACCESSORIES WITHIN ROOM TO BE REMOVED.
DF6 EXISTING PARTITION TO BE REMOVED IN ITS ENTIRETY.
DF8 EXISTING SHELVING TO BE REMOVED.
DF9 DASHED LINE DENOTES PATCH & REPAIR WALL AT WALL BASE AND REMOVE EXISTING WALL BASE. PREPARE FOR NEW WORK.
DF10 FLOOR DRAIN, SEE PLUMBING.
DF12 REMOVE OPERABLE PARTITION WALL AND HARDWARE IN ITS ENTIRETY.
DF13 TRENCHING REQUIRED FOR NEW PLUMBING FIXTURE. REFER TO NEW WORK DRAWING AND PLUMBING DRAWINGS TO
DETERMINE EXTENTS.
DF14 REMOVE RESTROOM PLACARD AND SAVE FOR FUTURE USE.
DF15 EXISTING ELECTRICAL BOX TO BE REMOVED, REFER TO ELECTRICAL DRAWINGS.
DF16 EXISTING DOOR AND FRAME TO BE SALVAGED FOR REUSE. HARDWARE TO BE REMOVED.
DF17 EXISTING WHITE BOARDS AND WALL ACCESSORIES TO BE SALVAGED OR RELOCATED, CONSULT WITH DISTRICT/OWNER.
12" = 1'-0"
7 EXISTING CONDITIONS - TEACHER RESOURCE ROOM
12" = 1'-0"
9 EXISTING CONDITIONS - CLASSROOM 162
12" = 1'-0"
6 EXISTING CONDITIONS - MENS STAFF RESTROOM
12" = 1'-0"
8 EXISTING CASEWORK @ TEACHERS RESOURCE ROOM
1/4" = 1'-0"
1 OVERALL FIRST FLOOR PLAN DEMOLITION - FUTURE PRACTICAL LABS
N
# Description Date
2. DEMOLITION SHEET NOTES APPLY TO ALL DEMOLITION SHEETS.
3. EXISTING CONSTRUCTION TO REMAIN IS SHOWN HALF-TONED AND SHADED AS INDICATED IN LEGEND. CONSTRUCTION SCHEDULED FOR DEMOLITION IS SHOWN IN FULL-TONED DASHED LINES AND MAY INCLUDE RED SHADING. THE INTENT OF DEMOLITION IS SHOWN GRAPHICALLY AND NOT ALL ITEMS INDICATED TO BE DEMOLISHED WILL NECESSARILY BE INDIVIDUALLY TAGGED FOR DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION INTENT WHETHER ITEM IS TAGGED
OR NOT.
4. PRIOR TO DEMOLITION, CONTRACTOR SHALL REVIEW ALL NEW WORK AND COORDINATE DEMOLITION REQUIREMENTS TO ACCOMMODATE NEW WORK. THE FULL EXTENT OF DEMOLITION REQUIRED FOR THE NEW WORK MAY NOT BE FULLY DESCRIBED
ON THE DEMOLITION DRAWINGS.
5. THESE DRAWINGS HAVE BEEN DEVELOPED FROM EXISTING INFORMATION, WHICH MAY NOT REFLECT ACTUAL FIELD CONDITIONS. CONTRACTOR SHALL FIELD VERIFY THESE DRAWINGS WITH ALL EXISTING FIELD CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF INCONSISTENCIES WITH ACTUAL CONDITIONS PRIOR TO PROCEEDING WITH CONSTRUCTION.
6. PRIOR TO ANY DEMOLITION, THE CONTRACTOR SHALL VERIFY EXISTING SYSTEMS AND BUILDING SERVICES SERVING OTHER PORTIONS OF THE BUILDING AND COORDINATE ANY REQUIRED RELOCATION WORK WITH THE OWNER. ANY DISRUPTION TO EXISTING BUILDING SERVICES SHALL BE STRICTLY COORDINATED WITH DESIGNATED SCHOOL REPRESENTATIVE PRIOR TO
DISRUPTING ANY EXISTING SERVICE. OBTAIN WRITTEN APPROVAL PRIOR TO PROCEEDING.
7. ALL EXISTING CONSTRUCTION SCHEDULED TO REMAIN SHALL BE PROTECTED DURING DEMOLITION. ANY EXISTING CONSTRUCTION DAMAGED DURING THE WORK SHALL BE REPAIRED OR REPLACED TO MATCH THE ORIGINAL CONDITION AND/OR ADJACENT CONSTRUCTION. ANY REMEDIAL REQUIRED SHALL BE AT NO ADDITIONAL COST TO THE OWNER.
8. ACTIVE PIPES, CONDUITS, AND OTHER UTILITIES OF ALL TYPES, WHETHER SHOWN IN THE CONSTRUCTION DOCUMENTS OR NOT, MUST BE PROTECTED AT ALL TIMES DURING THE CONSTRUCTION OF THE WORK. EXTREME CARE SHALL BE EXERCISED AT ALL TIMES NOT TO DAMAGE ANY SUCH PIPES AND CONDUITS. WHERE DAMAGE OCCURS, CONTRACTOR CAUSING THE DAMAGE SHALL REPAIR SUCH DAMAGE IN A MANNER APPROVED BY THE ARCHITECT AND OWNER, AND AT NO CHANGE IN THE CONTRACT
PRICES OF CONTRACTOR.
9. WHEN REMOVING WALL PARTITIONS REMOVE ALL ELEMENTS ATTACHED TO THE WALL, INCLUDING CONDUIT, WIRING, OUTLETS, SWITCHES, THERMOSTATS, CLOCKS, INTERCOM, PROJECTION SCREENS, TACK BOARDS, MARKER BOARDS, TACK PANELS, TACK STRIPS, FIRE ALARM DEVICES, PLUMBING FIXTURES, PIPES, ETC., UNLESS NOTED OTHERWISE. SEE MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
10. THE CONTRACTOR SHALL CAREFULLY SALVAGE AND STORE EXISTING ITEMS CALLED OUT TO BE RELOCATED/ REINSTALLED.
REPAIR ANY DAMAGE TO ALL EXISTING SURFACES AND ITEMS BEING SALVAGED FOR REUSE/REINSTALL.
11. PATCH & REPAIR ALL HOLES, DAMAGE, ETC. IN EXISTING CONSTRUCTION REMAINING AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE. PATCH & REPAIR WORK SHALL MATCH EXISTING ADJACENT SURFACES & MATERIALS, UNLESS
NOTED OTHERWISE. SEE NEW WORK FOR ADDITIONAL INFORMATION.
12. THE CONTRACTOR SHALL PATCH AND REPAIR MATERIALS AND FINISHES TO MATCH EXISTING ADJACENT AT AREAS OF MEP
DEMOLITION AND INSTALLATION. COORDINATE WITH MEP SHEETS.
DEMOLITION PLAN LEGEND
EXISTING PARTITION
EXISTING SMOKE PARTITION
EXISTING TWO HOUR BUILDING SEPARATION
EXISTING PARTITION TO BE REMOVED
EXISTING WINDOW & FRAME
EXISTING WINDOW TO BE
REMOVED
EXISTING DOOR & FRAME
EXISTING DOOR & FRAME TO BE REMOVED
EXISTING AREA TO BE DEMOLISHED.
VERIFY IN FIELD PRIOR TO DEMOLITION
AREA NOT IN SCOPE
EXISTING ONE-HOUR FIRE PARTITION
D
C
B
1 2 3 4 4.1 54.91.1
A
A.1
CLASSROOM 163
DISPENSERY
CLASSROOM 163
STORAGE
CLASSROOM 164
CORRIDOR
CORRIDOR
STORAGE
CLASSROOM 167
CLASSROOM 167
STORAGE
CLASSROOM 152
CLASSROOM 152
STORAGE
STORAGE
STORAGE
CLASSROOM 153
CLASSROOM 165
DATA CLOSET
NORTH STAIR
DF2
DF2
DF2
DF13
DF13
DF12
DF6
DF7
DF6
DF13
DF12
WMNS TOILET ROOM MENS TOILET ROOM
ELECTRICALDATA ROOM
CUSTODIAL CLOSET STORAGE
CLOSET
DF17
DF17
DF17
CC JOB NUMBER
DATE
DRAWING TITLE:
COPYRIGHT ©: CORDOGAN CLARK & ASSOCIATES, INC.
CONSULTANTS:
ARCHITECT:
REVISIONS:
5/ 7/
:1
9:
P M
AD1.02
254017
05/04/2026
ENLARGED FIRST
FLOOR
DEMOLITION PLAN -
FUTURE THEORY
LABS
C L
Y D
E C
. M
IL
L E
R A
C A
D E
M Y
C O
S M
E T
O L
O G
Y /B
A R
B E
R S
C H
O O
L R
E N
O V
A T
IO
N
S
N
O R
TH
G
R A
N D
B O
U
LE
V A
R D
S A
IN
T
LO
U
IS
, M
IS
S
O U
R I 6
S A
IN
T
L O
U
IS
P U
B L
IC
S
C H
O O
L S
B
ID
/ P E
R M
IT
S
E T
CORDOGAN CLARK & ASSOCIATES, INC
3001 LOCUST STREET
SECOND FLOOR
SAINT LOUIS, MISSOURI 63103
(314) 421-3542
MECHANICAL, ELECTRICAL & PLUMBING
OWNER'S REPRESENTATIVE:
ECS - CONSULTING ENGINEERS
14500 SOUTH OUTER FORTY ROAD, SUITE 108
TOWN & COUNTRY, MISSOURI 63017
(314) 370-0478
NAVIGATE BUILDING SOLUTIONS
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2019017440
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2018042187
8419 MANCHESTER ROAD
BRENTWOOD, MISSOURI 63144
(314) 713-6205
DEMOLITION FLOOR PLAN KEYNOTES
DF2 EXISTING VCT FLOORING TO BE REMOVED.
DF6 EXISTING PARTITION TO BE REMOVED IN ITS ENTIRETY.
DF7 EXISTING DOOR, FRAME & HARDWARE TO BE REMOVED IN ITS ENTIRETY.
DF12 REMOVE OPERABLE PARTITION WALL AND HARDWARE IN ITS ENTIRETY.
DF13 TRENCHING REQUIRED FOR NEW PLUMBING FIXTURE. REFER TO NEW WORK DRAWING AND PLUMBING DRAWINGS TO
DETERMINE EXTENTS.
DF17 EXISTING WHITE BOARDS AND WALL ACCESSORIES TO BE SALVAGED OR RELOCATED, CONSULT WITH DISTRICT/OWNER.
1/4" = 1'-0"
1 OVERALL FIRST FLOOR PLAN DEMOLITION - FUTURE THEORY LABS
N
# Description Date
2. DEMOLITION SHEET NOTES APPLY TO ALL DEMOLITION SHEETS.
3. EXISTING CONSTRUCTION TO REMAIN IS SHOWN HALF-TONED AND SHADED AS INDICATED IN LEGEND. CONSTRUCTION SCHEDULED FOR DEMOLITION IS SHOWN IN FULL-TONED DASHED LINES AND MAY INCLUDE RED SHADING. THE INTENT OF DEMOLITION IS SHOWN GRAPHICALLY AND NOT ALL ITEMS INDICATED TO BE DEMOLISHED WILL NECESSARILY BE INDIVIDUALLY TAGGED FOR DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION INTENT WHETHER ITEM IS TAGGED
OR NOT.
4. PRIOR TO DEMOLITION, CONTRACTOR SHALL REVIEW ALL NEW WORK AND COORDINATE DEMOLITION REQUIREMENTS TO ACCOMMODATE NEW WORK. THE FULL EXTENT OF DEMOLITION REQUIRED FOR THE NEW WORK MAY NOT BE FULLY DESCRIBED
ON THE DEMOLITION DRAWINGS.
5. THESE DRAWINGS HAVE BEEN DEVELOPED FROM EXISTING INFORMATION, WHICH MAY NOT REFLECT ACTUAL FIELD CONDITIONS. CONTRACTOR SHALL FIELD VERIFY THESE DRAWINGS WITH ALL EXISTING FIELD CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF INCONSISTENCIES WITH ACTUAL CONDITIONS PRIOR TO PROCEEDING WITH CONSTRUCTION.
6. PRIOR TO ANY DEMOLITION, THE CONTRACTOR SHALL VERIFY EXISTING SYSTEMS AND BUILDING SERVICES SERVING OTHER PORTIONS OF THE BUILDING AND COORDINATE ANY REQUIRED RELOCATION WORK WITH THE OWNER. ANY DISRUPTION TO EXISTING BUILDING SERVICES SHALL BE STRICTLY COORDINATED WITH DESIGNATED SCHOOL REPRESENTATIVE PRIOR TO
DISRUPTING ANY EXISTING SERVICE. OBTAIN WRITTEN APPROVAL PRIOR TO PROCEEDING.
7. ALL EXISTING CONSTRUCTION SCHEDULED TO REMAIN SHALL BE PROTECTED DURING DEMOLITION. ANY EXISTING CONSTRUCTION DAMAGED DURING THE WORK SHALL BE REPAIRED OR REPLACED TO MATCH THE ORIGINAL CONDITION AND/OR ADJACENT CONSTRUCTION. ANY REMEDIAL REQUIRED SHALL BE AT NO ADDITIONAL COST TO THE OWNER.
8. ACTIVE PIPES, CONDUITS, AND OTHER UTILITIES OF ALL TYPES, WHETHER SHOWN IN THE CONSTRUCTION DOCUMENTS OR NOT, MUST BE PROTECTED AT ALL TIMES DURING THE CONSTRUCTION OF THE WORK. EXTREME CARE SHALL BE EXERCISED AT ALL TIMES NOT TO DAMAGE ANY SUCH PIPES AND CONDUITS. WHERE DAMAGE OCCURS, CONTRACTOR CAUSING THE DAMAGE SHALL REPAIR SUCH DAMAGE IN A MANNER APPROVED BY THE ARCHITECT AND OWNER, AND AT NO CHANGE IN THE CONTRACT
PRICES OF CONTRACTOR.
9. WHEN REMOVING WALL PARTITIONS REMOVE ALL ELEMENTS ATTACHED TO THE WALL, INCLUDING CONDUIT, WIRING, OUTLETS, SWITCHES, THERMOSTATS, CLOCKS, INTERCOM, PROJECTION SCREENS, TACK BOARDS, MARKER BOARDS, TACK PANELS, TACK STRIPS, FIRE ALARM DEVICES, PLUMBING FIXTURES, PIPES, ETC., UNLESS NOTED OTHERWISE. SEE MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
10. THE CONTRACTOR SHALL CAREFULLY SALVAGE AND STORE EXISTING ITEMS CALLED OUT TO BE RELOCATED/ REINSTALLED.
REPAIR ANY DAMAGE TO ALL EXISTING SURFACES AND ITEMS BEING SALVAGED FOR REUSE/REINSTALL.
11. PATCH & REPAIR ALL HOLES, DAMAGE, ETC. IN EXISTING CONSTRUCTION REMAINING AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE. PATCH & REPAIR WORK SHALL MATCH EXISTING ADJACENT SURFACES & MATERIALS, UNLESS
NOTED OTHERWISE. SEE NEW WORK FOR ADDITIONAL INFORMATION.
12. THE CONTRACTOR SHALL PATCH AND REPAIR MATERIALS AND FINISHES TO MATCH EXISTING ADJACENT AT AREAS OF MEP
DEMOLITION AND INSTALLATION. COORDINATE WITH MEP SHEETS.
DEMOLITION CEILING LEGEND
CEILING TO BE DEMOLISHED
AREA NOT IN SCOPE
OPEN TO STRUCTUREOTS
ACOUSTICAL CEILING TILE
TO BE DEMOLISHED
2'x4' LIGHT FIXTURE TO BE
DEMOLISHED
2'x2' LIGHT FIXTURE TO BE
DEMOLISHED
SURFACE-MOUNTED LINEAR LIGHT
FIXTURE TO BE DEMOLISHED
E
D
F
1 2 3 4 4.1 54.91.1
TEACHER RESOURCE
ROOM
MENS STAFF
RESTROOM
WMNS STAFF
RESTROOM
OFFICE
GYM
EQUIPMENT
STORAGE
DATA ROOM ELECTRICAL
CUSTODIAL CLOSET STORAGE
DC4
TYP
DC7
DC1
7 / AD1.01
DC4
/ A
D 1.
CORRIDOR
CLASSROOM 162
STORAGE
CLASSROOM 162
DC2
DC1
CORRIDOR
CLASSROOM 147
WOMENS TOILET
ROOM
CLASSROOM 147
STORAGE
CUSTODIAL
CLOSET
MENS TOILET
ROOM
DC7 DC8
OTS OTS
DC4
DC7
DC1
ALIGN
CC JOB NUMBER
DATE
DRAWING TITLE:
COPYRIGHT ©: CORDOGAN CLARK & ASSOCIATES, INC.
CONSULTANTS:
ARCHITECT:
REVISIONS:
5/ 7/
:1
9:
P M
AD3.01
254017
05/04/2026
ENLARGED FIRST
FLOOR RCP
DEMOLITION PLAN -
FUTURE
PRACTICAL LABS
C L
Y D
E C
. M
IL
L E
R A
C A
D E
M Y
C O
S M
E T
O L
O G
Y /B
A R
B E
R S
C H
O O
L R
E N
O V
A T
IO
N
S
N
O R
TH
G
R A
N D
B O
U
LE
V A
R D
S A
IN
T
LO
U
IS
, M
IS
S
O U
R I 6
S A
IN
T
L O
U
IS
P U
B L
IC
S
C H
O O
L S
B
ID
/ P E
R M
IT
S
E T
CORDOGAN CLARK & ASSOCIATES, INC
3001 LOCUST STREET
SECOND FLOOR
SAINT LOUIS, MISSOURI 63103
(314) 421-3542
MECHANICAL, ELECTRICAL & PLUMBING
OWNER'S REPRESENTATIVE:
ECS - CONSULTING ENGINEERS
14500 SOUTH OUTER FORTY ROAD, SUITE 108
TOWN & COUNTRY, MISSOURI 63017
(314) 370-0478
NAVIGATE BUILDING SOLUTIONS
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2019017440
MISSOURI CERTIFICATE OF AUTHORITY
NO. 2018042187
8419 MANCHESTER ROAD
BRENTWOOD, MISSOURI 63144
(314) 713-6205
DEMOLITION REFLECTED CEILING KEYNOTES
DC1 EXISTING ACT TILE CEILING & GRID TO REMAIN.
DC2 SECTION OF EXISTING ACT TILE CEILING & GRID TO BE REMOVED.
DC4 EXISTING LIGHTING FIXTURE(S) TO BE REMOVED.
DC7 EXISTING GYPSUM CEILING TO BE REMOVED.
DC8 EXISTING TRACK & HARDWARE TO OPERABLE PARTITION WALL TO BE REMOVED IN ITS ENTIRETY.
1/4" = 1'-0"
1 ENLARGED FIRST FLOOR RCP DEMO PLAN - FUTURE PRACTICAL PLANS
N
# Description Date
2. DEMOLITION SHEET NOTES APPLY TO ALL DEMOLITION SHEETS.
3. EXISTING CONSTRUCTION TO REMAIN IS SHOWN HALF-TONED AND SHADED AS INDICATED IN LEGEND. CONSTRUCTION SCHEDULED FOR DEMOLITION IS SHOWN IN FULL-TONED DASHED LINES AND MAY INCLUDE RED SHADING. THE INTENT OF DEMOLITION IS SHOWN GRAPHICALLY AND NOT ALL ITEMS INDICATED TO BE DEMOLISHED WILL NECESSARILY BE INDIVIDUALLY TAGGED FOR DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION INTENT WHETHER ITEM IS TAGGED
OR NOT.
4. PRIOR TO DEMOLITION, CONTRACTOR SHALL REVIEW ALL NEW WORK AND COORDINATE DEMOLITION REQUIREMENTS TO ACCOMMODATE NEW WORK. THE FULL EXTENT OF DEMOLITION REQUIRED FOR THE NEW WORK MAY NOT BE FULLY DESCRIBED
ON THE DEMOLITION DRAWINGS.
5. THESE DRAWINGS HAVE BEEN DEVELOPED FROM EXISTING INFORMATION, WHICH MAY NOT REFLECT ACTUAL FIELD CONDITIONS. CONTRACTOR SHALL FIELD VERIFY THESE DRAWINGS WITH ALL EXISTING FIELD CONDITIONS AND NOTIFY THE ARCHITECT IMMEDIATELY OF INCONSISTENCIES WITH ACTUAL CONDITIONS PRIOR TO PROCEEDING WITH CONSTRUCTION.
6. PRIOR TO ANY DEMOLITION, THE CONTRACTOR SHALL VERIFY EXISTING SYSTEMS AND BUILDING SERVICES SERVING OTHER PORTIONS OF THE BUILDING AND COORDINATE ANY REQUIRED RELOCATION WORK WITH THE OWNER. ANY DISRUPTION TO EXISTING BUILDING SERVICES SHALL BE STRICTLY COORDINATED WITH DESIGNATED SCHOOL REPRESENTATIVE PRIOR TO
DISRUPTING ANY EXISTING SERVICE. OBTAIN WRITTEN APPROVAL PRIOR TO PROCEEDING.
7. ALL EXISTING CONSTRUCTION SCHEDULED TO REMAIN SHALL BE PROTECTED DURING DEMOLITION. ANY EXISTING CONSTRUCTION DAMAGED DURING THE WORK SHALL BE REPAIRED OR REPLACED TO MATCH THE ORIGINAL CONDITION AND/OR ADJACENT CONSTRUCTION. ANY REMEDIAL REQUIRED SHALL BE AT NO ADDITIONAL COST TO THE OWNER.
8. ACTIVE PIPES, CONDUITS, AND OTHER UTILITIES OF ALL TYPES, WHETHER SHOWN IN THE CONSTRUCTION DOCUMENTS OR NOT, MUST BE PROTECTED AT ALL TIMES DURING THE CONSTRUCTION OF THE WORK. EXTREME CARE SHALL BE EXERCISED AT ALL TIMES NOT TO DAMAGE ANY SUCH PIPES AND CONDUITS. WHERE DAMAGE OCCURS, CONTRACTOR CAUSING THE DAMAGE SHALL REPAIR SUCH DAMAGE IN A MANNER APPROVED BY THE ARCHITECT AND OWNER, AND AT NO CHANGE IN THE CONTRACT
PRICES OF CONTRACTOR.
9. WHEN REMOVING WALL PARTITIONS REMOVE ALL ELEMENTS ATTACHED TO THE WALL, INCLUDING CONDUIT, WIRING, OUTLETS, SWITCHES, THERMOSTATS, CLOCKS, INTERCOM, PROJECTION SCREENS, TACK BOARDS, MARKER BOARDS, TACK PANELS, TACK STRIPS, FIRE ALARM DEVICES, PLUMBING FIXTURES, PIPES, ETC., UNLESS NOTED OTHERWISE. SEE MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
10. THE CONTRACTOR SHALL CAREFULLY SALVAGE AND STORE EXISTING ITEMS…