13283_Cullinary_Arts_Drawings_9-26-25.pdf

PDF 4 MB Posted

Attached to
Culinary Arts Modernization Project
Solicitation number
WSH2511A
Issued by
Los Angeles County, San Francisco City, California

About this file

These are architectural and engineering drawings for the Culinary Arts Classroom Modernization Project, a multi-site construction initiative managed by the William S. Hart Union High School District in California. The project encompasses culinary arts classroom upgrades across six high schools located in Santa Clarita and surrounding areas: Bowman, Canyon, Golden Valley, Valencia, West Ranch, and William S. Hart High Schools. The scope of work includes removal and replacement of countertops, sinks, and electrical infrastructure at all six sites. At four schools (Bowman, Golden Valley, Valencia, and West Ranch), work involves removing plastic laminate countertops and replacing them with stainless steel countertops featuring integral sinks, along with new overhead power drops. At the remaining two schools (Canyon and William S. Hart), the project requires removal and replacement of damaged quartz countertops with new quartz surfaces and replacement of sinks and trim at all locations, plus new overhead power drops. The project is divided into two phases: Phase 1 is scheduled during Winter Break from December 22, 2025, to January 9, 2026, and Phase 2 from March 25, 2026, to June 30, 2026. A mandatory job walk is scheduled for October 15, 2025, at 10:00 am at Golden Valley High School, with electronic bid submissions required by November 3, 2025, at 2:00 pm via the District's eProcurement Portal.

The drawings provide detailed floor plans, reflected ceiling plans, plumbing fixture schedules, and electrical layouts for each school site. The plumbing work specifies stainless steel fixtures including single and double bowl kitchen sinks with Chicago Faucet models featuring 8-inch swing spouts and 1.5 GPM aerators, along with provisions for reinstalling existing garbage disposals. Electrical requirements include installation of industrial cord reels with GFCI protection, new receptacles, and conduit runs to support the modernization efforts. The project requires compliance with 2022 California Building Code standards, California Fire Code, California Electrical Code, and other applicable state regulations. Contractors must possess an active Class B (General Contractor) license and comply with prevailing wage laws, Department of Industrial Relations requirements, Workers' Compensation Experience Modification Rate limits of 1.25 or less, and maintain zero Serious and Willful violations in the past five years. The project will be executed under the Statewide Educational Wrap Up Program (SEWUP) Joint Powers Authority providing an Owner Controlled Insurance Program with approximately $800 million in total liability coverage. The district includes a $50,000 owner-controlled allowance in the project budget.

View the file

Other files

File Type Posted
Culinary_Arts_Modernization_Project.pdf PDF
Culinary_Arts_Modernization_Project.pdf PDF
(10)_PWC100_DIR_INFO_(1).pdf PDF
2-Certification_of_Safety_Program_(1).pdf PDF
(6)_Safety_Program_A_(1).pdf PDF
1-Substitution_Request_(1).pdf PDF
2-Certification_of_Safety_Program_(1).pdf PDF
1-Substitution_Request_(1).pdf PDF
13283_Culinary_Arts_Specifications_9-26-25.pdf PDF
(2)_Perfomance_Bond_(1).pdf PDF
(3)_Payment_Bond_Blank_(1).pdf PDF
(4)_Drug_and_Tobacco_(1).pdf PDF
(5)_Company_Guarantee_to_Owner_(1).pdf PDF
(6)_Safety_Program_A_(1).pdf PDF
1-Substitution_Request_(1).pdf PDF
13283_Culinary_Arts_Specifications_9-26-25.pdf PDF
(2)_Perfomance_Bond_(1).pdf PDF
(5)_Company_Guarantee_to_Owner_(1).pdf PDF
13283_Culinary_Arts_Specifications_9-26-25.pdf PDF
13283_Cullinary_Arts_Drawings_9-26-25.pdf PDF
DOJ_Rev._5.08.25_Certification_of_Employee_Background_Check.pdf PDF
(11)_Workers_Compensation_Exemption_Declaration_Construction_(1).pdf PDF
(5)_Company_Guarantee_to_Owner_(1).pdf PDF
2-Certification_of_Safety_Program_(1).pdf PDF
(11)_Workers_Compensation_Exemption_Declaration_Construction_(1).pdf PDF
13283_Cullinary_Arts_Drawings_9-26-25.pdf PDF
DOJ_Rev._5.08.25_Certification_of_Employee_Background_Check.pdf PDF
5-Conditional_Waiver_and_Release_(Upon_Final_Payment).pdf PDF
Agree__Hart__Front_End_GC__General_Provisions_Rev_6.26.23JF_(Rev_6.21.24_Added_Blue_Beam_Illustration_Method_&_Insurance).pdf PDF
CM-MP_Construction_Services_Agreement_2019_informal_and_formal_bids_CUPCCAA.pdf PDF
(1)_Asbestos-Free_Materials.pdf PDF
4-Unconditional_Waiver_and_Release_(Upon_Progress_Payment).pdf PDF
5-Conditional_Waiver_and_Release_(Upon_Final_Payment).pdf PDF
(1)_Asbestos-Free_Materials.pdf PDF
Agree__Hart__Front_End_GC__General_Provisions_OCIP_Rev_6.26.23JF_(Rev_6.21.24_Added_Blue_Beam_Illustration_Method).pdf PDF
CM-MP_Construction_Services_Agreement_2019_informal_and_formal_bids_CUPCCAA.pdf PDF
(7)_Lead_Containing_176349_(1).pdf PDF
3-Conditional_Waiver_and_Release_(upon_Progress_Payment).pdf PDF
4-Unconditional_Waiver_and_Release_(Upon_Progress_Payment).pdf PDF
6-Unconditional_Waiver_and_Release_(Upon_Final_Payment).pdf PDF
Agree__Hart__Front_End_CM-MP__General_Provisions_OCIP_Rev_6.26.23JF_(Rev_6.21.24_Added_Blue_Beam_Illustration_Method).pdf PDF
Agree__Hart__Front_End_GC__General_Provisions_OCIP_Rev_6.26.23JF_(Rev_6.21.24_Added_Blue_Beam_Illustration_Method).pdf PDF
Blank_IRS_W-9_(2024).pdf PDF
GC_Construction_Services_Agreement_2019.pdf PDF
3-Conditional_Waiver_and_Release_(upon_Progress_Payment).pdf PDF
5-Conditional_Waiver_and_Release_(Upon_Final_Payment).pdf PDF
6-Unconditional_Waiver_and_Release_(Upon_Final_Payment).pdf PDF
GC_Construction_Services_Agreement_2019.pdf PDF
(1)_Asbestos-Free_Materials.pdf PDF
GC_Construction_Services_Agreement_2019.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OWNER

WILLIAM S. HART UNION HIGH

SCHOOL DISTRICT

21380 CENTRE POINTE POINTE PARKWAY

SANTA CLARITA, CA. 91350

(661) 259-0033

CONTACT: JACK KAPP

E-MAIL: jkapp@hartdistrict.org

PROJECT ARCHITECT

TETER, INC.

10000 STOCKDALE HWY, SUITE 350

BAKERSFIELD, CA. 93311

(661) 843-8400

CONTACT: JAMIE N. MILLER

E-MAIL: jamie.miller@teterae.com

ELECTRICAL ENGINEER

TETER, INC.

10000 STOCKDALE HWY, SUITE 350

BAKERSFIELD, CA. 93311

(661) 843-8400

CONTACT: JASON MARCH

E-MAIL: jason.march@teterae.com

MECHANICAL/ PLUMBING ENGINEER

TETER, INC.

7535 N. PALM AVE., SUITE 201

FRESNO, CA. 93711

(559) 437-0887

CONTACT: FERNAN SIOCON

E-MAIL: fernan.siocon@teterae.com

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. G000

COVER PAGE

CULINARY ARTS CLASSROOM MODERNIZATION

AT VARIOUS SITES

FOR WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

GENERAL

G000 COVER PAGE

G001 GENERAL NOTES AND GOVERNING CODES

ARCHITECTURAL

A000 ABBREVIATIONS

A100 SITE PLANS

A210 BOWMAN HIGH SCHOOL - FLOOR PLAN

A220 CANYON HIGH SCHOOL - FLOOR PLAN

A225 CANYON HIGH SCHOOL - REFLECTED CEILING PLAN

A230 GOLDEN VALLEY HIGH SCHOOL - FLOOR PLAN

A235 GOLDEN VALLEY HIGH SCHOOL - REFLECTED CEILING PLAN

A240 VALENCIA HIGH SCHOOL - FLOOR PLAN

A245 VALENCIA HIGH SCHOOL - REFLECTED CEILING PLAN

A250 WEST RANCH HIGH SCHOOL - FLOOR PLAN

A255 WEST RANCH HIGH SCHOOL - REFLECTED CEILING PLAN

A260 WILLIAM S. HART HIGH SCHOOL - FLOOR PLAN

A265 WILLIAM S. HART HIGH SCHOOL - REFLECTED CEILING PLAN

A800 DETAILS

A801 DETAILS

A802 DETAILS

A803 DETAILS

PLUMBING

P100 PLUMBING FIXTURE SCHEDULE

ELECTRICAL

E001 ELECTRICAL SCHEDULES, LEGENDS, AND NOTES

E210 BOWMAN HIGH SCHOOL - ELECTRICAL FLOOR PLAN

E220 CANYON HIGH SCHOOL - ELECTRICAL FLOOR PLAN

E230 GOLDEN VALLEY HIGH SCHOOL - ELECTRICAL FLOOR PLAN

E240 VALENCIA HIGH SCHOOL - ELECTRICAL FLOOR PLAN

E250 WEST RANCH HIGH SCHOOL - ELECTRICAL FLOOR PLAN

E260 WILLIAM S. HART HIGH SCHOOL - ELECTRICAL FLOOR PLAN

E600 ELECTRICAL DETAILS

PROJECT DESCRIPTION

THE PROJECT CONSISTS OF THE FOLLOWING ITEMS BUT NOT NECESSARILY LIMITED TO:

AT BOWMAN, GOLDEN VALLEY, VALENCIA, AND WEST RANCH HIGH SCHOOL SITES WITH

PLASTIC LAMINATE COUNTERTOPS (4 SITES):

• REMOVAL OF SINKS AND TRIM AS INDICATED ON DRAWINGS.

• REMOVAL OF PLASTIC LAMINATE COUNTERTOPS AND REPLACEMENT WITH STAINLESS

STEEL COUNTERTOPS, STAINLESS STEEL WITH INTEGRAL SINKS AND TRIM.

• NEW OVERHEAD POWER DROPS (WITH THE EXCEPTION OF BOWMAN HIGH SCHOOL).

• RELOCATION OF POWER RECEPTACLE AT BOWMAN HIGH SCHOOL.

AT CANYON AND WILLIAM S. HART HIGH SCHOOL WITH QUARTZ COUNTERTOPS:

• REMOVAL AND REPLACEMENT OF DAMAGED QUARTZ COUNTER TOPS AS INDICATED ON

DRAWINGS.

• REMOVAL AND REPLACEMENT OF SINKS AND TRIM AT ALL COUNTER TOPS AS INDICATED

ON DRAWINGS.

• NEW OVERHEAD POWER DROPS.

SHEET INDEXPROJECT DIRECTORY

PROJECT ADDRESSES

• BOWMAN HIGH SCHOOL: 21508 CENTRE POINTE PARKWAY

SANTA CLARITA, CA. 91350

• CANYON HIGH SCHOOL: 19300 W. NADAL STREET

CANYON COUNTRY, CA. 91351

• GOLDEN VALLEY HIGH SCHOOL: 27051 ROBERT C. LEE PARKWAY

SANTA CLARITA, CA. 91350

• VALENCIA HIGH SCHOOL: 27801 NORTH DICKASON DRIVE

VALENCIA, CA. 91355

• WEST RANCH HIGH SCHOOL: 26255 WEST VALENCIA BLVD.

STEVENSON RANCH, CA. 91381

• WILLIAM S. HART HIGH SCHOOL: 24825 NORTH NEWHALL AVE.

SANTA CLARITA, CA. 91321

AT CANYON AND WILLIAM S. HART HIGH SCHOOL WITH QUARTZ COUNTERTOPS:

• REMOVAL AND REPLACEMENT OF DAMAGED QUARTZ COUNTER TOPS AS INDICATED ON

DRAWINGS.

• REMOVAL AND REPLACEMENT OF SINKS AND TRIM AT ALL COUNTER TOPS AS INDICATED

ON DRAWINGS.

• NEW OVERHEAD POWER DROPS.

A. FOR ACCESSIBLE SINK KNEE/TOE SPACE, SEE

B. CONTRACTOR SHALL PATCH, REPAIR OR REPLACE ANY ADJACENT WORK

(WALL, CEILING, FLOOR SURFACES, ETC.) THAT IS DAMAGED, REMOVED

AND/OR DEMOLISHED DURING THE COURSE OF CONSTRUCTION. SEE

SPECIFICATION REQUIREMENTS FOR CUTTING & PATCHING.

C. ALL WORK WITHIN OR ON EXISTING WALLS SHALL BE PATCHED TO MATCH

THE ADJACENT EXISTING CONDITIONS, INCLUDING BUT NOT LIMITED TO ALL

DEMOLITION REQUIRED TO PROPERLY INSTALL PROPOSED IMPROVEMENTS

(STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, ETC.).

a. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION REGARDING

CUTTING & PATCHING REQUIREMENTS.

b. COORDINATE WITH RESPECTIVE TRADES FOR THE EXTENT OF

DEMOLITION AND PATCHBACK REQUIRED TO PROPERLY INSTALL

PROPOSED IMPROVEMENTS.

2 / A801

GENERAL NOTES

A. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. DIMENSIONS PROVIDED

ARE FOR ESTIMATING PURPOSES AND SHALL NOT BE USED FOR

CONSTRUCTION OF NEW COUNTERTOPS.

B. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR REVIEW AND

APPROVAL BY OWNER AND ARCHITECT PRIOR TO FABRICATION OF

COUNTERTOPS AND INTEGRAL SINKS.

SHOP DRAWINGS

2022 CALIFORNIA ADMINISTRATIVE CODE (CAC), C.C.R. TITLE 24, PART 1

2022 CALIFORNIA BUILDING CODE (CBC), C.C.R. TITLE 24, PART 2

2022 CALIFORNIA ELECTRICAL CODE (CEC), C.C.R. TITLE 24, PART 3

2022 CALIFORNIA MECHANICAL CODE (CMC), C.C.R. TITLE 24, PART 4

2022 CALIFORNIA PLUMBING CODE (CPC), C.C.R. TITLE 24, PART 5

2022 CALIFORNIA FIRE CODE (CFC), C.C.R. TITLE 24, PART 9

2022 CALIFORNIA REFERENCED STANDARDS CODE, C.C.R. TITLE 24, PART 12

2022 CALIFORNIA ENERGY CODE (CAC), C.C.R. TITLE 24, PART 6

2022 CALIFORNIA EXISTING BUILDING CODE (CEBC), C.C.R. TITLE 24, PART 10

2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN),

C.C.R. TITLE 24, PART 11

C.C.R. TITLE 19, PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS

NFPA 14 STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS

(CA AMENDED 2019 EDITION)

NFPA 17 STANDARD FOR DRY CHEMICAL EXTINGUISHING SYSTEMS, 2021 EDITION

NFPA 17A STANDARD FOR WET CHEMICAL EXTINGUISHING SYSTEMS, 2021 EDITION

NFPA 20 STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE

PROTECTION, 2019 EDITION

NFPA 22 STANDARD WATER TANKS FOR PRIVATE FIRE PROTECTION, 2018 EDITION

NFPA 24 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS

AND THEIR APPURTENANCES (CA AMENDED), 2019 EDITION

NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE (AS AMENDED), 2022 EDITION

NFPA 80 STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES,

2019 EDITION

NFPA 2001 STANDARD ON CLEAN AGENT FIRE EXTINGUISHING SYSTEM (CA AMENDED),

2018 EDITION

UL 300 STANDARD FOR FIRE TESTING OF FIRE EXTINGUISHING SYSTEM FOR

PROTECTION OF COMMERCIAL COOKING EQUIPMENT 2005 (R2014)

UL 464 AUDIBLE SIGNALING DEVICES FOR FIRE ALARM AND SIGNALING SYSTEMS,

INCLUDING ACCESSORIES, 2003 EDITION

UL 521 STANDARD FOR HEAT DETECTORS FOR FIRE PROTECTIVE SIGNALING

SYSTEMS, 1999 EDITION (R2005)

UL 1971 STANDARD FOR SIGNALING DEVICES FOR THE HEARING IMPAIRED 2002 (R2012)

FOR A COMPLETE LIST OF APPLICABLE NFPA STANDARDS, INCLUDING CALIFORNIA AMENDMENTS TO

THE NFPA STANDARDS, REFER TO 2022 CALIFORNIA BUILDING CODE (CBC) CHAPTER 35 AND

CALIFORNIA FIRE CODE (CFC) CHAPTER 80

GOVERNING CODES

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. G001

GENERAL NOTES AND GOVERNING CODES

ABBREVIATIONS: WHEN USED IN THESE DOCUMENTS SHALL CONFORM TO THE FOLLOWING LIST UNLESS OTHERWISE NOTED. DRAWINGS OF OTHER DISCIPLINES (SUCH AS CIVIL, STRUCTURAL, PLUMBING, MECHANICAL, AND ELECTRICAL) MAY CONTAIN SPECIFIC ABBREVIATIONS, REFERENCES, AND LEGENDS

WITH INTERPRETATION INTENDED ONLY FOR THOSE DISCIPLINES.

CL

ABBREVIATIONSABBREVIATIONS

& AND

L ANGLE

@ AT

CENTERLINE

Ø DIAMETER OR ROUND

PERPENDICULAR

# POUND OR NUMBER

(E) EXISTING

(N) NEW

ABV. ABOVE

A.B. ANCHOR BOLT

A/C AIR CONDITIONING

ACP ASPHAULT CONCRETE

PAVING

ACST. ACOUSTICAL

A.C.T. ACOUSTIC CEILING TILE

ADA AMERICANS WITH

DISABILITIES ACT

ADAAG ADA ACCESSIBLE

GUIDELINES

ADDL. ADDITIONAL

ADJ. ADJUSTABLE

ADJC. ADJACENT

A.F.F. ABOVE FINISH FLOOR

A.F.G. ABOVE FINISH GRADE

AGG. AGGREGATE

ALT. ALTERNATE

ALUM. ALUMINUM

ANOD. ANODIZED

A.P.C. ACOUSTIC PANEL CEILING

APPROX. APPROXIMATE

ARCH. ARCHITECT(URAL)

AV AUDIO VISUAL

BD. BOARD

BEL. BELOW

B.E.N BOUNDARY EDGE NAILING

BLDG. BUILDING

BLK. BLOCK

BLKG. BLOCKING

BM. BEAM

BOT. BOTTOM

BRG. BEARING

BTWN. BETWEEN

B.U.R. BUILT-UP ROOF(ING)

C&G CURB AND GUTTER

CAB. CABINET

C.B. CARRIAGE BOLT

CEM. CEMENT

CER. CERAMIC

C.F. CUBIC FOOT

C.I. CAST IRON

C.J. CONSTRUCTION JOINT

C.L. CENTERLINE

C.L.F. CHAIN LINK FENCE

CLG. CEILING

CLO. CLOSET

CLR. CLEAR

CL.RM. CLASS ROOM

CMU CONCRETE MASONRY

UNIT

CTR. COUNTER

COL. COLUMN

CONC. CONCRETE

CONN. CONNECTION

CONSTR. CONSTRUCTION

CONT. CONTINUOUS

CONTR. CONTRACTOR

CPT. CARPET

CRC COLD ROLLED CHANNEL

CTR. CENTER

CTSK COUNTERSUNK

C.Y. CUBIC YARD

D.A. DISABLED ACCESS

DBL. DOUBLE

DEMO DEMOLISH/DEMOLITION

D.F. DRINKING FOUNTAIN OR

DOUGLASS FIR

DET. DETAIL

DIAG. DIAGONAL

DIA. DIAMETER

DIM. DIMENSION

DISP. DISPENSER

DN. DOWN

DP. DEEP

DS DOWN SPOUT

DWG.(S) DRAWING(S)

DWR. DRAWER

E EAST

EA. EACH

E.F. EXHAUST FAN

EGR. ENGINEER

E.J. EXPANSION JOINT

EL. ELEVATION

ELEC. ELECTRIC(AL)

ELEV. ELEVATOR

EMB. EMBEDMENT

EMER. EMERGENCY

E.N. EDGE NAILING

ENCL. ENCLOSURE

EQ. EQUAL

EQUIP. EQUIPMENT

EV ELECTRIC VEHICLE

EVCS ELECTRIC VEHICLE

CHARGING STATION

EVSE ELECTRIC VEHICLE

SUPPLY EQUIPMENT

EVAP. EVAPORATIVE

E.W. EACH WAY

EXH. EXHAUST

EXST. EXISTING

EXP. EXPANSION

EXT. EXTERIOR

FA FIRE ALARM

F.B. FLAT BAR

F.B.O FURNISHED BY

OWNER/OTHERS

F.D. FLOOR DRAIN

F.D.C. FIRE DEPARTMENT

CONNECTION

FDN. FOUNDATION

F.E. FIRE EXTINGUISHER

F.E.C FIRE EXTINGUISHER

CABINET

F.F. FACTORY FINISH

F. FLR. FINISH FLOOR

F.G. FINISH GRADE

F.H. FIRE HYDRANT

FHMS FLAT HEAD

MACHINE SCREW

FHWS FLAT HEAD WOOD

SCREW

FIN. FINISH

FIXT. FIXTURE

FLR. FLOOR(ING)

FLASH. FLASHING

FLUOR. FLUORESCENT

F.O. FACE OF

F.O.C. FACE OF CONCRETE

F.O.F. FACE OF FINISH

F.O.M. FACE OF MASONRY

F.O.S FACE OF STUD

FRP FIBERGLASS REIN-

FORCED PANELING

F.S. FIRE SPRINKLER(S)

F.S.H. FIRE SPRINKLER

HEAD

FT. FOOT/FEET

FURR. FURRING

FUT. FUTURE

SYMBOLS

ANGLE

DIAMETER OR ROUND

PERPENDICULAR

& AND

@ AT

CENTER LINE

# POUND OR NUMBER

TYPICAL SYMBOLS

KEYNOTE SYMBOL

DETAIL

CEILING HEIGHT

LOCATION ON SHEET REFERENCED

SHEET NUMBER WHERE DETAIL IS LOCATED

KEYNOTE REFERENCE, REFER TO

KEYNOTE LIST ON SHEET

00.00

XX

XXXX

+10'-0"

S SOUTH

S.A. SUPPLY AIR

S.C. SOLID CORE

SCH. SCHEDULE

S.D. STORM DRAIN

SECT. SECTION

SF SQUARE FOOT/FEET

SHR. SHOWER

SHTG. SHEATHING

SIM SIMILAR

S.M. SHEET METAL

S.M.S SHEET METAL SCREW

S.O.G. SLAB-ON-GRADE

SPEC(S) SPECIFICATION(S)

SPKR. SPEAKER

SQ. SQUARE

S.S. STAINLESS STEEL

STA. STATION

STC SOUND TRANSMISSION

CLASS

STD. STANDARD

STL. STEEL

STOR. STORAGE

STRUCT. STRUCTURAL

SUSP. SUSPENDED

S.W. SIDE WALK

SYS. SYMMETRICAL

T.C. TOP OF CONCRETE

TEMP. TEMPORARY

TMPD. TEMPERED

T&G TONGUE & GROOVE

THD. THREADED

THK. THICK

T.I. TENANT IMPROVEMENT

TK.BD. TACK BOARD

T.O.S. TOP OF STEEL

T.O. TOP OF PAVEMENT

TS TUBE STEEL

TEL. TELEPHONE

TTB TELEPHONE TERMINAL

BACK BOARD

TV TELEVISION

TYP. TYPICAL

U.G. UNDERGROUND

U.N.O UNLESS NOTED

OTHERWISE

UR. URINAL

VCT VINYL COMPOSITION

TILE

VERT. VERTICAL

VTR VENT TO ROOG

VWC VINYL WALL COVERING

W WEST OF WIDTH/WIDE

W/ WITH

W.C. WATER CLOSET

W.CH. WHEEL CHAIR

WD. WOOD

WDW. WINDOW

WF WIDE FLANGE

W.H. WATER HEATER

W/O WITHOUT

W.P. WATERPROOF

W.S. WOOD SCREW

WT. WEIGHT

WWF WELDED WIRE FABRIC

XFMR TRANSFORMER

N. NORTH

N.I.C. NOT IN CONTRACT

NO. NUMBER

NOM. NOMINAL

N.R.C. NOISE REDUCTION

COEFFICIENT

N.T.S NOT TO SCALE

OCC OCCUPANT LOAD

O.C. ON CENTER

O.D. OUTSIDE DIAMETER/

DIMENSION

OFF. OFFICE

OFCI OWNER FURNISHED,

CONTR. INSTALLED

OFOI OWNER FURNISHED,

OWNER INSTALLED

O.F.R.D OVER FLOW ROOF

DRAIN

O.H. OPPOSITE HAND

O.H.C.D. OVER HEAD COILING

DOOR

O.H.M.S. OVAL HEAD MACH.

SCREW

O.H.W.S OVAL HEAD WOOD

SCREW

OPNG. OPENING

OPP. OPPOSITE

O/ OVER

ORIG. ORIGINAL

OVHD OVERHEAD

OWJ OPEN WEB JOIST

P.B.N. PLYWOOD BOUNDARY

NAILING

P.E.N. PLYWOOD EDGE

NAILING

P.E.S. PLYWOOD EDGE

SCREW

P.I.V. POST INDICATOR

VALVE

P.LAM PLASTIC LAMINATE

P.L. PROPERTY LINE

PL. PLATE

PLAS. PLASTER

PLYWD. PLYWOOD

PR. PAIR

PSF POUNDS PER

SQUARE FOOT

PSI POUNDS PER

SQUARE INCH

PT. POINT

P.T.D. PAPER TOWEL DISP.

P.T.D.F. PRESSURE TREATED

DOUGLAS FIR

PTN. PARTITION

PVC POLYVINYL CHLORIDE

R. RADIUS

R THERMAL RESISTANCE

R.A. RETURN AIR

R.D. ROOF DRAIN

REFL. REFLECTED

REFR. REFRIGERATOR

REINF. REINFORCED

REM. REMOVE

REQD. REQUIRED

RESIL. RESILIENT

R.H. RIGHT HAND

R.H.W.S. ROUND HEAD WOOD

SCREW

RM. ROOM

R.O. ROUGH OPENING

R.O.W RIGHT-OF-WAY

RWD. REDWOOD

RWL RAIN WATER LEADER

GA. GAUGE

GALV. GALVANIZED

G.B. GRAB BAR

G.C. GENERAL CONTR.

GEN. GENERAL

G.I. GALVANIZED IRON

GL. GLASS

GND. GROUND

GR. GRADE

GYP. GYPSUM

H.B. HOSE BIBB

HBD. HARDBOARD

H.C. HOLLOW CORE

HD. HEAD

H.D. HEAVY DUTY

HDR. HEADER

HDW. HARDWARE

HDWD. HARDWOOD

H.M. HOLLOW METAL

H.M.D. HOLLOW METAL DOOR

H.M.F. HOLLOW METAL FRAME

HORIZ. HORIZONTAL

HR. HOUR

HT. HEIGHT

HVAC HEATING/VENTILATING/

AIR CONDITIONING

HWY HIGH WAY

I.D. INSIDE DIAMETER/

DIMENSION

INFO INFORMATION

INT. INTERIOR

JAN. JANITOR

JT. JOINT

KIT. KITCHEN

K.O. KNOCK OUT

K.O.P. KNOCK OUT PANEL

LAB. LABORATORY

LAM. LAMINATE

LAV. LAVATORY

LB(S) POUND(S)

L.B. LAG BOLT

L.F. LINEAL FOOT

L.H. LEFT HAND

LIB. LIBRARY

LT. LIGHT

LT.WT. LIGHT WEIGHT

MACH. MACHINE

MAINT. MAINTENANCE

MAX. MAXIMUM

M.B. MACHINE BOLT

M.B.M. METAL BUILDING

MANUFACTURER

MECH. MECHANICAL

MED. MEDIUM

MEMB. MEMBRANE

MET. METAL

MFR. MANUFACTURER

MH. MANHOLE

MKR. MARKER

MIN. MINIMUM

MISC. MISCELLANEOUS

M.O. MASONRY OPENING

MTD. MOUNTED

MTG. MEETING

MULL. MULLION

CODE AND ORGANIZATIONS

CBC CALIFORNIA BUILDING CODE

CEC CALIFORNIA ELECTRICAL CODE

CFC CALIFORNIA FIRE CODE

CMC CALIFORNIA MECHANICAL CODE

CPC CALIFORNIA PLUMBING CODE

DSA DIVISION OF THE STATE ARCHITECT

ICBO INTERNATIONAL CONFERENCE OF BUILDING

OFFICIALS

NSF NATIONAL SANITATION FOUNDATION

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NEC NATIONAL ELECTRICAL CODE

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A000

ABBREVIATIONS

NORTH

(E) CULINARY

ARTS

CLASSROOM

NORTH

(E) CULINARY ARTS

CLASSROOM

NORTH

(E) CULINARY ARTS

CLASSROOM

(LOWER LEVEL)

NORTH

(E) CULINARY

ARTS

CLASSROOM

NORTH

(E) CULINARY

ARTS

CLASSROOM

NORTH

(E) CULINARY

ARTS

CLASSROOM

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A100

SITE PLANS

BOWMAN HIGH SCHOOL CANYON HIGH SCHOOL GOLDEN VALLEY HIGH SCHOOL

VALENCIA HIGH SCHOOL WEST RANCH HIGH SCHOOL WILLIAM S. HART HIGH SCHOOL

21508 CENTRE POINTE PARKWAY

SANTA CLARITA, CA. 91350

27801 NORTH DICKASON DRIVE

VALENCIA, CA. 91355

19300 W. NADAL STREET

CANYON COUNTRY, CA. 91351

26255 WEST VALENCIA BLVD.

STEVENSON RANCH, CA. 91381

24825 NORTH NEWHALL AVE.

SANTA CLARITA, CA. 91321

27051 ROBERT C. LEE PARKWAY

SANTA CLARITA, CA. 91350

8' - 4" 6' - 4"

5'

- 0

1' - 0"

2' - 6"

9'

- 0

6" 8'

- 0

2' - 0"

3' - 0"

2'

- 0

S-4

3' - 0"

5'

- 0

S-5S-5 (E)

REF.

(E)

DW

(E)

REF.

(E)

DW

7' - 6"

(E) CULINARY

ARTS

CLASSROOM

11.21

11.22

2.02

2.04

9' - 4"

2' - 0"2' - 0"

9' - 4" 7"

2.05 2.05

LEGEND

REMOVE EXISTING SINK AND TRIM. PROVIDE NEW

STAINLESS STEEL SINK INTEGRAL WITH THE STAINLESS

STEEL COUNTERTOP. PROVIDE NEW TRIM AT SINKS AND

CONNECT SUPPLY AND WASTE PIPING.

SEE PLUMBING FIXTURE SCHEDULE.

REMOVE EXISTING PLASTIC LAMINATE COUNTERTOP AND

BACK SPLASH (PROTECT EXISTING CABINETS. UPPER

CABINETS NOT SHOWN FOR CLARITY). PROVIDE 1" THICK

PLYWOOD SUBTOP AND INTEGRAL STAINLESS STEEL SINK

AND TRIM.

S-# SEE PLUMBING FIXTURE SCHEDULE, P100

EXISTING STUD WALL TO REMAIN

REMOVE EXISTING PLASTIC LAMINATE WALL CAP AT

PARTIAL HEIGHT WALL; PROVIDE NEW STAINLESS STEEL

WALL CAP. SEE ELECTRICAL FOR RELOCATION OF POWER.

MINIMUM 30" X 48" WHEEL CHAIR CLEAR SPACE

MAINTAIN ACCESSIBLE COUNTER TOP HEIGHT, DEPTH

AND KNEE CLEARANCE, SEE DETAIL 2 / A801

00.00 KEYNOTES

1 / A800

2 / A800

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A210

BOWMAN HIGH SCHOOL - FLOOR PLAN

FLOOR PLAN

SCALE: 1/8" = 1'-0"

NORTH

2.02 EXISTING TALL STORAGE TO REMAIN, TYP. (PROTECT DURING

CONSTRUCTION)

2.04 EXISTING PANTRY TO REMAIN (PROTECT DURING

CONSTRUCTION)

2.05 REMOVE AND SALVAGE EXISTING GARBAGE DISPOSAL. INSTALL

AT NEW SINK, TYP.

11.21 NEW STAINLESS STEEL COUNTERTOP, SEE DETAIL

11.22 NEW STAINLESS STEEL CAP ON PARTIAL HEIGHT WALL, SEE

DETAIL

0"TYP.

3' - 3"

6'

- 0

6' - 0"

2' - 0"

(E) CLASSROOM

S-1

(E) OFFICE (E) SUPPLY

(E) VESTIBULE

(E) CLASSROOM

S-2

8'

- 0

2'

- 0

S-2

S-2

S-2

S-2

S-2

(E)

REF.

(E) CULINARY

ARTS

CLASSROOM

(E)

REF.

(E)

REF.

0"

S-2

(E)

REF.

4' - 6"

2.03

4'

- 0

2.05

2.03

2.05

2.05

2.05

S-2

2.05

2.05

2.05

12.13

12.13

5' - 3"

LEGEND

REMOVE EXISTING SINK AND TRIM. PROVIDE NEW SELF

RIMMING STAINLESS STEEL SINKS AND TRIM. CONNECT

SUPPLY AND WASTE PIPING.

SEE PLUMBING FIXTURE SCHEDULE.

REMOVE EXISTING QUARTZ COUNTERTOP AND BACK

SPLASH (PROTECT EXISTING CABINETS. UPPER CABINETS

NOT SHOWN FOR CLARITY). PROVIDE NEW QUARTZ

COUNTERTOP AND STAINLESS STEEL SINK AND TRIM.

S-# SEE PLUMBING FIXTURE SCHEDULE, P100

EXISTING STUD WALL TO REMAIN

EXISTING QUARTZ COUNTERTOP TO REMAIN

MINIMUM 30" X 48" WHEEL CHAIR CLEAR SPACE

MAINTAIN ACCESSIBLE COUNTER TOP HEIGHT, DEPTH

AND KNEE CLEARANCE, SEE DETAIL 2 / A801

00.00 KEYNOTES

1 / A801

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A220

CANYON HIGH SCHOOL - FLOOR PLAN

FLOOR PLAN

SCALE: 1/8" = 1'-0"

NORTH

2.03 EXISTING COOKING RANGE, TYP. (PROTECT DURING

CONSTRUCTION)

2.05 REMOVE AND SALVAGE EXISTING GARBAGE DISPOSAL. INSTALL

AT NEW SINK, TYP.

12.13 NEW QUARTZ COUNTER TOP, SEE

8'-0"

8'-0" 8'-0"

8'-0"

10'-0"

(E) CLASSROOM

(E) SUPPLY

(E) VESTIBULE

(E) CLASSROOM

(E) OFFICE

(E) CULINARY

ARTS

CLASSROOM

9.41

LEGEND

EXISTING SUSPENDED ACOUSTIC PANEL CEILING SYSTEM

TO REMAIN

EXISTING CEILING TO REMAIN

1'-0" CEILING HEIGHT

EXISTING ELECTRICAL LIGHT FIXTURE TO REMAIN

EXISTING MECHANICAL GRILLES TO REMAIN

POWER CORD REEL, SEE ELECTRICAL DETAIL ON

SHEET E600. ATTACH TO STRUCTURE ABOVE,

SEE DETAILS ON SHEETS A802 AND A803.

00.00 KEYNOTES

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A225

CANYON HIGH SCHOOL - REFLECTED CEILING PLAN

REFLECTED CEILING PLAN

SCALE: 1/8" = 1'-0"

NORTH

9.41 TRIM EXISTING SUSPENDED ACOUSTIC PANEL CEILING AS

REQUIRED TO ACCOMMODATE NEW CORD REEL, TYP. PROVIDE

CROSS RUNNER TO SUPPORT TRIMMED PANEL. CROSS RUNNER

TO MATCH EXISTING, TYP.

2' - 0"

7' - 3"

5' - 3"

3'

3"

2' - 8"

(E) CULINARY

ARTS

CLASSROOM

S-5 S-5 S-5

S-5 S-5 S-5

S-6 (E)

LAUNDRY

(E)

STORAGE

(E)

OFFICE

9'

- 1

2' - 0" 3' - 7 1/2" 2' - 0"11"

S-5

2.03

11.21

11.22

2.05 2.05 2.05

2.052.052.05

2.05

LEGEND

REMOVE EXISTING SINK AND TRIM. PROVIDE NEW

STAINLESS STEEL SINK INTEGRAL WITH THE STAINLESS

STEEL COUNTERTOP. PROVIDE NEW TRIM AT SINKS AND

CONNECT SUPPLY AND WASTE PIPING.

SEE PLUMBING FIXTURE SCHEDULE.

REMOVE EXISTING PLASTIC LAMINATE COUNTERTOP AND

BACK SPLASH (PROTECT EXISTING CABINETS. UPPER

CABINETS NOT SHOWN FOR CLARITY). PROVIDE 1" THICK

PLYWOOD SUBTOP AND INTEGRAL STAINLESS STEEL SINK

AND TRIM.

S-# SEE PLUMBING FIXTURE SCHEDULE, P100

EXISTING STUD WALL TO REMAIN

REMOVE EXISTING PLASTIC LAMINATE WALL CAP AT

PARTIAL HEIGHT WALL; PROVIDE NEW STAINLESS STEEL

WALL CAP.

MINIMUM 30" X 48" WHEEL CHAIR CLEAR SPACE

MAINTAIN ACCESSIBLE COUNTER TOP HEIGHT, DEPTH

AND KNEE CLEARANCE, SEE DETAIL 2 / A801

00.00 KEYNOTES

1 / A800

2 / A800

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A230

GOLDEN VALLEY HIGH SCHOOL - FLOOR PLAN

FLOOR PLAN

SCALE: 1/8" = 1'-0"

NORTH

2.03 EXISTING COOKING RANGE, TYP. (PROTECT DURING

CONSTRUCTION)

2.05 REMOVE AND SALVAGE EXISTING GARBAGE DISPOSAL. INSTALL

AT NEW SINK, TYP.

11.21 NEW STAINLESS STEEL COUNTERTOP, SEE DETAIL

LEGEND

EXISTING SUSPENDED ACOUSTIC PANEL CEILING SYSTEM

TO REMAIN

EXISTING CEILING TO REMAIN

1'-0" CEILING HEIGHT

EXISTING ELECTRICAL LIGHT FIXTURE TO REMAIN

EXISTING MECHANICAL GRILLES TO REMAIN

POWER CORD REEL, SEE ELECTRICAL DETAIL ON

SHEET E600. ATTACH TO STRUCTURE ABOVE,

SEE DETAILS ON SHEETS A802 AND A803.

(E) CULINARY

ARTS

CLASSROOM

(E)

LAUNDRY

(E)

STORAGE

(E)

OFFICE

9.41

9'-0"

00.00 KEYNOTES

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A235

GOLDEN VALLEY HIGH SCHOOL - REFLECTED CEILING PLAN

REFLECTED CEILING PLAN

SCALE: 1/8" = 1'-0"

NORTH

9.41 TRIM EXISTING SUSPENDED ACOUSTIC PANEL CEILING AS

REQUIRED TO ACCOMMODATE NEW CORD REEL, TYP. PROVIDE

8' - 0"

3'

- 0

TY

P.

2'

- 0

11' - 4" 6' - 6"

8 ' -9" 1'

- 6

(E) CLASSROOM (E) CULINARY

ARTS

CLASSROOM

S-5

S-5 S-5 S-5

S-4

(E) STORAGE (E)

LAUNDRY

2.03

S-5

2' - 0" 5' - 5" 6"

3'

- 1

1" 2'

- 0

8'

- 2

11.22

2.05 2.05 2.05 2.05

11.21

00.00 KEYNOTES

1 / A800

2 / A800

LEGEND

REMOVE EXISTING SINK AND TRIM. PROVIDE NEW

STAINLESS STEEL SINK INTEGRAL WITH THE STAINLESS

STEEL COUNTERTOP. PROVIDE NEW TRIM AT SINKS AND

CONNECT SUPPLY AND WASTE PIPING.

SEE PLUMBING FIXTURE SCHEDULE.

REMOVE EXISTING PLASTIC LAMINATE COUNTERTOP AND

BACK SPLASH (PROTECT EXISTING CABINETS. UPPER

CABINETS NOT SHOWN FOR CLARITY). PROVIDE 1" THICK

PLYWOOD SUBTOP AND INTEGRAL STAINLESS STEEL SINK

AND TRIM.

S-# SEE PLUMBING FIXTURE SCHEDULE, P100

EXISTING STUD WALL TO REMAIN

REMOVE EXISTING PLASTIC LAMINATE WALL CAP AT

PARTIAL HEIGHT WALL; PROVIDE NEW STAINLESS STEEL

WALL CAP.

MINIMUM 30" X 48" WHEEL CHAIR CLEAR SPACE

MAINTAIN ACCESSIBLE COUNTER TOP HEIGHT, DEPTH

AND KNEE CLEARANCE, SEE DETAIL 2 / A801

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A240

VALENCIA HIGH SCHOOL - FLOOR PLAN

FLOOR PLAN

2.03 EXISTING COOKING RANGE, TYP. (PROTECT DURING

CONSTRUCTION)

2.05 REMOVE AND SALVAGE EXISTING GARBAGE DISPOSAL. INSTALL

AT NEW SINK, TYP.

11.21 NEW STAINLESS STEEL COUNTERTOP, SEE DETAIL

11.22 NEW STAINLESS STEEL CAP ON PARTIAL HEIGHT WALL, SEE

DETAIL

SCALE: 1/8" = 1'-0"

9'-0"

9'-0"

(E) STORAGE (E) LAUNDRY

(E) CLASSROOM (E) CULINARY

ARTS

CLASSROOM

9.41

LEGEND

EXISTING SUSPENDED ACOUSTIC PANEL CEILING SYSTEM

TO REMAIN

EXISTING CEILING TO REMAIN

1'-0" CEILING HEIGHT

EXISTING ELECTRICAL LIGHT FIXTURE TO REMAIN

EXISTING MECHANICAL GRILLES TO REMAIN

POWER CORD REEL, SEE ELECTRICAL DETAIL ON

SHEET E600. ATTACH TO STRUCTURE ABOVE,

SEE DETAILS ON SHEETS A802 AND A803.

00.00 KEYNOTES

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A245

VALENCIA HIGH SCHOOL - REFLECTED CEILING PLAN

REFLECTED CEILING PLAN

SCALE: 1/8" = 1'-0"

NORTH

9.41 TRIM EXISTING SUSPENDED ACOUSTIC PANEL CEILING AS

REQUIRED TO ACCOMMODATE NEW CORD REEL, TYP. PROVIDE

ARTS

CLASSROOM

(E) UTILITY

ROOM

(E)

STORAGE

(E)

OFFICE

S-5 S-5 S-5

S-5 S-5

S-6

7' - 3"

5' - 3"

3'

- 1

0"

2' - 8"

S-5

1' - 0" 2' - 0" 3' - 7 1/2" 2' - 0"

4'

- 3

6'

- 1

0"

8'

- 1

2.03

11.21

11.22

S-5 9'

- 1

2.05 2.05 2.05

2.05

2.05 2.05 2.05

LEGEND

REMOVE EXISTING SINK AND TRIM. PROVIDE NEW

STAINLESS STEEL SINK INTEGRAL WITH THE STAINLESS

STEEL COUNTERTOP. PROVIDE NEW TRIM AT SINKS AND

CONNECT SUPPLY AND WASTE PIPING.

SEE PLUMBING FIXTURE SCHEDULE.

REMOVE EXISTING PLASTIC LAMINATE COUNTERTOP AND

BACK SPLASH (PROTECT EXISTING CABINETS. UPPER

CABINETS NOT SHOWN FOR CLARITY). PROVIDE 1" THICK

PLYWOOD SUBTOP AND INTEGRAL STAINLESS STEEL SINK

AND TRIM.

S-# SEE PLUMBING FIXTURE SCHEDULE, P100

EXISTING STUD WALL TO REMAIN

REMOVE EXISTING PLASTIC LAMINATE WALL CAP AT

PARTIAL HEIGHT WALL; PROVIDE NEW STAINLESS STEEL

WALL CAP.

MINIMUM 30" X 48" WHEEL CHAIR CLEAR SPACE

MAINTAIN ACCESSIBLE COUNTER TOP HEIGHT, DEPTH

AND KNEE CLEARANCE, SEE DETAIL 2 / A801

00.00 KEYNOTES

1 / A800

2 / A800

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A250

WEST RANCH HIGH SCHOOL - FLOOR PLAN

FLOOR PLAN

SCALE: 1/8" = 1'-0"

NORTH

2.03 EXISTING COOKING RANGE, TYP. (PROTECT DURING

CONSTRUCTION)

2.05 REMOVE AND SALVAGE EXISTING GARBAGE DISPOSAL. INSTALL

AT NEW SINK, TYP.

11.21 NEW STAINLESS STEEL COUNTERTOP, SEE DETAIL

LEGEND

EXISTING SUSPENDED ACOUSTIC PANEL CEILING SYSTEM

TO REMAIN

EXISTING CEILING TO REMAIN

1'-0" CEILING HEIGHT

EXISTING ELECTRICAL LIGHT FIXTURE TO REMAIN

EXISTING MECHANICAL GRILLES TO REMAIN

POWER CORD REEL, SEE ELECTRICAL DETAIL ON

SHEET E600. ATTACH TO STRUCTURE ABOVE,

SEE DETAILS ON SHEETS A802 AND A803.

(E) CULINARY

ARTS

CLASSROOM

(E) UTILITY

ROOM

(E)

STORAGE

(E)

OFFICE

9.41

9'-0"

00.00 KEYNOTES

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A255

WEST RANCH HIGH SCHOOL - REFLECTED CEILING PLAN

FLOOR PLAN

SCALE: 1/8" = 1'-0"

NORTH

9.41 TRIM EXISTING SUSPENDED ACOUSTIC PANEL CEILING AS

REQUIRED TO ACCOMMODATE NEW CORD REEL, TYP.

PROVIDE CROSS RUNNER TO SUPPORT TRIMMED PANEL.

CROSS RUNNER TO MATCH EXISTING, TYP.

5' - 0" 2' - 0"

5'

- 0

(E) CULINARY

ARTS

CLASSROOM

(E) HEATER

(E)

LAUNDRY

(E)

TOILET

(E)

JAN

(E)

ENTRY

(E)

OFFICE

(E) SEWING

(E)

CLASSROOM

8"

2.02

S-3S-3S-3S-3

2.052.052.052.05

S-3S-3

2.052.05

S-32.05 12.13

2.03

LEGEND

REMOVE EXISTING SINK AND TRIM. PROVIDE NEW SELF

RIMMING STAINLESS STEEL SINKS AND TRIM. CONNECT

SUPPLY AND WASTE PIPING,

SEE PLUMBING FIXTURE SCHEDULE.

REMOVE EXISTING QUARTZ COUNTERTOP AND BACK SPLASH

(PROTECT EXISTING CABINETS. UPPER CABINETS NOT SHOWN

FOR CLARITY). PROVIDE NEW QUARTZ COUNTERTOP AND

STAINLESS STEEL SINK AND TRIM.

S-# SEE PLUMBING FIXTURE SCHEDULE, P100

EXISTING STUD WALL TO REMAIN

EXISTING QUARTZ COUNTERTOP TO REMAIN

MINIMUM 30" X 48" WHEEL CHAIR CLEAR SPACE

MAINTAIN ACCESSIBLE COUNTER TOP HEIGHT, DEPTH

AND KNEE CLEARANCE, SEE DETAIL 2 / A801

00.00 KEYNOTES

1 / A801

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A260

WILLIAM S. HART HIGH SCHOOL - FLOOR PLAN

FLOOR PLAN

SCALE: 1/8" = 1'-0"

NORTH

2.02 EXISTING TALL STORAGE TO REMAIN, TYP. (PROTECT DURING

CONSTRUCTION)

2.03 EXISTING COOKING RANGE, TYP. (PROTECT DURING

CONSTRUCTION)

2.05 REMOVE AND SALVAGE EXISTING GARBAGE DISPOSAL. INSTALL

AT NEW SINK, TYP.

12.13 NEW QUARTZ COUNTER TOP, SEE

ARTS

CLASSROOM

(E) HEATER

(E)

TOILET

(E)

JAN

(E)

ENTRY

(E)

OFFICE

(E) SEWING

(E)

CLASSROOM

(E)

LAUNDRY

9.41

LEGEND

EXISTING SUSPENDED ACOUSTIC PANEL CEILING SYSTEM

TO REMAIN

EXISTING CEILING TO REMAIN

1'-0" CEILING HEIGHT

EXISTING ELECTRICAL LIGHT FIXTURE TO REMAIN

EXISTING MECHANICAL GRILLES TO REMAIN

POWER CORD REEL, SEE ELECTRICAL DETAIL ON

SHEET E600. ATTACH TO STRUCTURE ABOVE,

SEE DETAILS ON SHEETS A802 AND A803.

00.00 KEYNOTES

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A265

WILLIAM S. HART HIGH SCHOOL - REFLECTED CEILING PLAN

REFLECTED CEILING PLAN

SCALE: 1/8" = 1'-0"

NORTH

9.41 TRIM EXISTING SUSPENDED ACOUSTIC PANEL CEILING AS

REQUIRED TO ACCOMMODATE NEW CORD REEL, TYP.

PROVIDE CROSS RUNNER TO SUPPORT TRIMMED PANEL.

CROSS RUNNER TO MATCH EXISTING, TYP.

DEMOLITION

REMOVE EXISTING PLASTIC

LAMINATE COUNTERTOP AND

PLYWD. SUBSTRATE WHERE

OCCURS. SEE FLOOR PLAN.

REMOVE EXISTING

SINK AND FAUCET

EXISTING RUBBER TOP

SET BASE TO REMAIN

(E ) 2

PROPOSED

MARINE EDGE

STAINLESS STEEL

COUNTERTOP, SEE

14 GA INTEGRAL STAINLESS

STEEL SINK, BACKSPLASH,

AND COUNTERTOP OVER 1"

THICK PLYWOOD SUBSTRATE

3 / A800

FAUCET, SEE PLUMBING

FIXTURE SCHEDULE

NOTE: FOR COUNTERTOP HEIGHT,

KNEE AND TOE CLEARANCE AT

ACCESSIBLE UNITS, SEE

EXISTING PLASTIC LAMINATE

BASE CABINET AND DOOR

PANELS TO REMAIN (PROTECT

(E) BASE CABINETS DURING

CONSTRUCTION, TYP.)

2 / A801

EXISTING WALL

EXTEND & CLOSE ENDS

14 GA. STAINLESS STEEL

COUNTER ADHERED TO

(1) LAYER OF 1" PLYWOOD

1 1/2"

SEE FLOOR PLAN

FOR CAP WIDTH

EXISTING HT.

AT WALL

/2

14 GA. MARINE EDGE

STAINLESS STEEL

COUNTERTOP

1" THICK PLYWOOD

SUBSTRATE

1"

25" MAX.

INTEGRAL SINK

WHERE OCCURS,

SEE FLOOR PLAN

EXISTING

BASE CABINET AND

DOOR PANELS

BACKSPLASH

EXISTING WALL

33 1/2"

34" MAX

AT ACCESSIBLE

STATIONS

/2

1/ 2"

L

IP

/2

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A800

DETAILS

1 1/2" = 1'-0" 2S.S. CAP AT PONY WALL

1 1/2" = 1'-0" 3MARINE EDGE S.S. COUNTERTOP STAINLESS STEEL COUNTERTOP 13/4" = 1' - 0"

QUARTZ COUNTERTOP W/

4" BACKSPLASH O/ 3/4"

PLYWOOD SUBSTRATE,

PLYWOOD THICKNESS TO

MATCH EXISTING. COLOR AS

SELECTED BY ARCHITECT

FROM MANUFACTURER'S

FULL RANGE OF COLORS

STAINLESS STEEL

SINK AND FAUCET,

SEE P100 FOR PLUMBING

FIXTURE SCHEDULE

REMOVE EXISTING QUARTZ

COUNTERTOP AND PLYWD.

SUBSTRATE WHERE OCCURS,

SEE FLOOR PLAN

EXISTING BASE & TOE KICK

TO REMAIN WH/OCCURS

EXISTING RUBBER TOP

SET BASE TO REMAIN

EXISTING PLASTIC LAMINATE

BASE CABINET AND DOOR

PANELS TO REMAIN (PROTECT

(E) BASE CABINETS DURING

CONSTRUCTION, TYP.)

(E ) 2

DEMOLITION

PROPOSED

NOTE: FOR COUNTERTOP HEIGHT,

KNEE AND TOE CLEARANCE AT

ACCESSIBLE UNITS, SEE 2 / A801

REMOVE EXISTING

SINK AND FAUCET

COUNTERTOP

SINK

M

IN

13" MIN.**

3" MAX. 10" MIN.**

M

IN

C O

U N

T E

R S

H A

L L N

O T

M

A X

T

O P

O F

S

IN

K A

N D

/O R

E X

C E

E D

M A

X

H E

IG

H

T

25" MAX.

NOTES:

1. ACCESSIBLE SINKS SHALL

COMPLY WITH CBC SECTION

11B-606 AND 11B-305. A MIN.

30"x48" CLEAR SPACE SHALL BE

PROVIDED IN FRONT OF THE

SINK TO ALLOW FOR A

FORWARD APPROACH. A MIN.

30" WIDE CLEAR SPACE SHALL

EXTEND A MIN. OF 19"

UNDERNEATH THE COUNTER.

2. WATER SUPPLY AND DRAIN

PIPES SHALL BE INSULATED OR

OTHERWISE CONFIGURED TO

PROTECT AGAINST CONTACT.

THERE SHALL BE NO SHARP OR

ABRASIVE SURFACES UNDER

SINKS.

3. FAUCETS AND CONTROLS

SHALL BE OPERABLE WITH ONE

HAND AND SHALL NOT REQUIRE

TIGHT GRASPING, PINCHING, OR

TWISTING OF THE WRIST. THE

FORCE REQUIRED TO OPERATE

CONTROLS SHALL NOT EXCEED

A 5 LB. FORCE. SELF CLOSING

VALVES SHALL REMAIN OPEN

FOR AT LEAST 10 SECONDS.

6" MAX. (TOE SPACE

BEYOND KNEE SPACE)

CLEAR SPACE, 19" MIN./

25" MAX., (NOT LESS

THAN REACH DEPTH)

**INCREASE BY 1" FOR

EACH 1" INCREASE IN

CLEAR SPACE DEPTH

BEYOND 19"

SRH_12_2019

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A801

DETAILS

3/4" = 1'-0" 2ACCESSIBLE SINK CLEARANCE QUARTZ COUNTERTOP 13/4" = 1' - 0"

HANGER BETWEEN JOISTS

EXISTING

"I" JOIST

PL. 1/4"x3" SQ.

WASHER

(4) 3/8" THREADED ROD

SUPPORT WITH STIFFENER

FOR HOSE REEL ENCLOSURE,

24" X 14" (+/-) BOLT PATTERN,

SEE E600

4x6 BLKG. w/ U46 HANGERSADDITIONAL NUT, HAND TIGHTEN

EXISTING ROOF

SHEATHING

(3) 16d END

NAILS AT

BLK'G, TYP.

50# MAX. WT.

1"x8" VERT. WEB STIFFENER EA. SIDE, TYP. FACE NAIL w/

(4) 8dx2-1/2" NAILS. (WEB

STIFFENER SHALL BE SHTG.

w/ FACE GRAIN VERTICAL)

PROVIDE 1/8"

MIN./2-3/4"

MAX. GAP EQ

. S

PA

CE

D

(8

8d

VALENCIA HIGH SCHOOL

3"x2"x1/8"x2"L ANGLE CLIP.

ATTACH TO BLOCKING W/ (2) 1/4"x2"

LAG SCREWS, TYP.

(4) 3/8" THREADED ROD SUPPORT WITH

STIFFENER FOR HOSE REEL ENCLOSURE,

24" X 14" (+/-) BOLT PATTERN, SEE E600

LOAD AND JAMB NUTS. (TYP. OF 4)

4x6 BLKG. w/ U46 HANGERS

EXISTING 2X ROOF FRAMING TO REMAIN

EXISTING ROOF SHEATHING

CANYON HIGH SCHOOL AND

WILLIAM S. HART HIGH SCHOOL

EXISTING GYP. BD.

TO REMAIN (AT

WILLIAM S. HART)

REMOVE EXISTING GYPSUM BOARD AS

REQUIRED TO INSTALL BLOCKING, ANGLE

CLIPS, THREADED RODS AND BRACING

WIRES. PATCH BACK GYPSUM BOARD TO

MATCH EXISTING (AT WILLIAM S. HART)

EXISTING WIDE FLANGE TO REMAIN

1/4"x3" BEAM CLAMPS WITH 3/8" U-BOLT

AND NUTS. TYP. OF 2 EACH BEAM, 4 PER

TRAPEZE. (UNISTRUT P2785 OR EQUIV.)

6'-0" < L < 12'-0" DBL 1-5/8"x1-5/8", 12 GA.

CHANNEL. (UNISTRUT

P1001 OR EQUIV)

(4) 3/8" THREADED ROD SUPPORT

WITH STIFFENER FOR HOSE REEL

ENCLOSURE, 24" X 14" (+/-) BOLT

PATTERN, SEE E600

L

CHANNEL NUT AND LOCK NUT

GOLDEN VALLEY AND WEST RANCH HIGH SCHOOL

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A802

DETAILS

ROD SUPPORT AT EXISTING 2X ROOF FRAMING 21 1/2" = 1' - 0"

ROD SUPPORT AT EXISTING WIDE FLANGE 31 1/2" = 1' - 0" ROD SUPPORT AT EXISTING "I"JOIST 11 1/2" = 1' - 0"

HANGER WIRE

BRACING WIRE JOIST OR RAFTER

FOR BRACING WIRES -

FULLY EMBED SCREW EYE

THREADS IN DIRECTION OF

WIRE

TO BOTTOM OF JOIST

WOOD JOIST/ RAFTER

1/4" DIA SCREW EYE

w/FULL THREAD

EMBEDMENT (1-1/2" MIN)

1/4" DIA SCREW EYE

W/FULL THREAD

EMBEDMENT (1-1/2" MIN)

NOTES:

A. 1/4 OF THE LENGTH OF THE END RUNNER WHICHEVER IS LESS

B. NAILS @ ENDS OF HORIZONTAL STRUTS ARE TO BE PLACED

WITH NAIL HEAD TOWARD CENTERLINE OF SPAN OF STRUT

HANGER WIRE

BRACING WIRE

TJI UPPER FLANGE

TJI LOWER FLANGE

1/8"

MIN.

1/4" DIA. SCREW EYE w/

1-1/2" MIN. PENETRATION

DO NOT INSERT SCREW EYES

PARALLEL TO LAMINATIONS

(DETAIL MAY ALSO BE USED AT

TOP

CHORD)

1/4" DIA SCREW EYE

w/FULL THREAD

EMBEDMENT (1-1/2" MIN)

DO NOT INSERT SCREW

INTO SIDE OF MICROLAM

1"

STRUCTURAL

BEAMS

ONLY

12 GA. x 1" WIDE x 4" LONG

CEILING CLIP

HANGER WIRE (TEST FOR

200 LBS.) - 3 TIGHT TURNS

IN 1-1/2" EACH END.

12 GA. x 1" WIDE x 4" LONG

CEILING CLIP

BRACING WIRE (TEST FOR

440 LBS.) - 4 TIGHT TURNS

IN 3" EACH END.

HILTI X-EDNI 16S12 POWER

PINS (0.145" X 5/8" w/ 1/2"

STEEL WASHER)

U.N.O.

1/2" MAX. U.N.O.

1/2" MAX.

TY

P.1/

2"

M

AX.3"

T Y

P

/2

M A

X

GOLDEN VALLEY AND WEST RANCH HIGH SCHOOL

VALENCIA HIGH SCHOOLCANYON HIGH SCHOOL

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. A803

DETAILS

CEILING SUPPORT WIRE 11 1/2" = 1' - 0"

PLUMBING FIXTURE SCHEDULE

MARK FIXTURE S OR W V CW HW DESCRIPTION

S-1

KITCHEN SINK

(SINGLE, ADA)

2" 1-1/2" 1/2" 1/2"

JUST MODEL SLADA17519A65-J, KITCHEN SINK, SINGLE BOWL, 18 GA 304 STAINLESS STEEL, LUSTROUS SATIN FINISH, 19"x18"x6-1/2", WITH 3- HOLES 8" O.C., CHICAGO FAUCET MODEL 1100-H8E35-317XKAB, WITH 8" SWING HIGH ARC SPOUT, VANDAL PROOF WRISTBLADE HANDLES, PRESSURE COMPENSATING AERATOR, 1.5 GPM, CERAMIC QUARTER TURN OPERATOR. PROVIDE (N) CHICAGO FAUCET BALL STOPS, QUARTER TURN WITH LEVER HANDLE AND THREADED INLET, AND STAINLESS STEEL BRAIDED FLEXIBLE SUPPLIES. PROVIDE (N) MCGUIRE HEAVY CHROME

PLATED CAST BRASS TRAPS AND TRAP ARMS. REINSTALL (E) GARBAGE DISPOSER, IF ANY.

S-2

KITCHEN SINK

(DOUBLE, ADA)

S-3

KITCHEN SINK

(DOUBLE, ADA)

S-4

TEACHERS INTEGRAL

SS KITCHEN SINK

(SINGLE, ADA)

JUST MODEL DLADA1933A65-J, KITCHEN SINK, DOUBLE BOWL, 18 GA, 304 STAINLESS STEEL, LUSTROUS SATIN FINISH, 33"x19-1/2"x6-1/2", WITH 3- HOLES 8" O.C., CHICAGO FAUCET MODEL 1100-H8E35-317XKAB, WITH 8" SWING HIGH ARC SPOUT, VANDAL PROOF WRISTBLADE HANDLES, PRESSURE COMPENSATING AERATOR, 1.5 GPM, CERAMIC QUARTER TURN OPERATOR. PROVIDE (N) CHICAGO FAUCET BALL STOPS, QUARTER TURN WITH LEVER HANDLE AND THREADED INLET, AND STAINLESS STEEL BRAIDED FLEXIBLE SUPPLIES. PROVIDE (N) MCGUIRE HEAVY CHROME

PLATED CAST BRASS TRAPS AND TRAP ARMS. REINSTALL (E) GARBAGE DISPOSER, IF ANY.

JUST MODEL DLADA2128A65-J, KITCHEN SINK, DOUBLE BOWL, 18 GA, 304 STAINLESS STEEL, LUSTROUS SATIN FINISH, 29"x22"x6-1/2", WITH 3- HOLES 8" O.C., CHICAGO FAUCET MODEL 1100-H8E35-317XKAB, WITH 8" SWING HIGH ARC SPOUT, VANDAL PROOF WRISTBLADE HANDLES, PRESSURE COMPENSATING AERATOR, 1.5 GPM, CERAMIC QUARTER TURN OPERATOR. PROVIDE (N) CHICAGO FAUCET BALL STOPS, QUARTER TURN WITH LEVER HANDLE AND THREADED INLET, AND STAINLESS STEEL BRAIDED FLEXIBLE SUPPLIES. PROVIDE (N) MCGUIRE HEAVY CHROME

PLATED CAST BRASS TRAPS AND TRAP ARMS. REINSTALL (E) GARBAGE DISPOSER, IF ANY.

CUSTOM KITCHEN SINK, SINGLE BOWL +/- 16"x13-/12"x6-1/2" DEEP BOWL, 14 GA, 304 STAINLESS STEEL, LUSTROUS SATIN FINISH, 3-HOLES 8" O.C., CHICAGO FAUCET MODEL 1100-H8E35-317XKAB, WITH 8" SWING HIGH ARC SPOUT, VANDAL PROOF WRISTBLADE HANDLES, PRESSURE COMPENSATING AERATOR, 1.5 GPM, CERAMIC QUARTER TURN OPERATOR. PROVIDE (N) CHICAGO FAUCET BALL STOPS, QUARTER TURN WITH LEVER HANDLE AND THREADED INLET, AND STAINLESS STEEL BRAIDED FLEXIBLE SUPPLIES. PROVIDE (N) MCGUIRE HEAVY CHROME PLATED

CAST BRASS TRAPS AND TRAP ARMS. REINSTALL (E) GARBAGE DISPOSER, IF ANY.

2" 1-1/2" 1/2" 1/2"

2" 1-1/2" 1/2" 1/2"

2" 1-1/2" 1/2" 1/2"

S-5

STUDENT INTEGRAL

SS KITCHEN SINK

(SINGLE ADA)

2" 1-1/2" 1/2" 1/2"

CUSTOM KITCHEN SINK, SINGLE BOWL +/- 25"x16"x6-1/2" DEEP BOWL, 14 GA, 304 STAINLESS STEEL, LUSTROUS SATIN FINISH, 3-HOLES 8" O.C., CHICAGO FAUCET MODEL 1100-H8E35-317XKAB, WITH 8" SWING HIGH ARC SPOUT, VANDAL PROOF WRISTBLADE HANDLES, PRESSURE COMPENSATING AERATOR, 1.5 GPM, CERAMIC QUARTER TURN OPERATOR. PROVIDE (N) CHICAGO FAUCET BALL STOPS, QUARTER TURN WITH LEVER HANDLE AND THREADED INLET, AND STAINLESS STEEL BRAIDED FLEXIBLE SUPPLIES. PROVIDE (N) MCGUIRE HEAVY CHROME PLATED

CAST BRASS TRAPS AND TRAP ARMS. REINSTALL (E) GARBAGE DISPOSER, IF ANY.

S-6

UTILITY INTEGRAL SS

SINK (SINGLE ADA)

CUSTOM KITCHEN SINK, SINGLE BOWL +/- 22"x16"x6-1/2" DEEP BOWL, 14 GA, 304 STAINLESS STEEL, LUSTROUS SATIN FINISH, 3-HOLES 8" O.C., CHICAGO FAUCET MODEL 1100-H8E35-317XKAB, WITH 8" SWING HIGH ARC SPOUT, VANDAL PROOF WRISTBLADE HANDLES, PRESSURE COMPENSATING AERATOR, 1.5 GPM, CERAMIC QUARTER TURN OPERATOR. PROVIDE (N) CHICAGO FAUCET BALL STOPS, QUARTER TURN WITH LEVER HANDLE AND THREADED INLET, AND STAINLESS STEEL BRAIDED FLEXIBLE SUPPLIES. PROVIDE (N) MCGUIRE HEAVY CHROME PLATED

CAST BRASS TRAPS AND TRAP ARMS. REINSTALL (E) GARBAGE DISPOSER, IF ANY.

2" 1-1/2" 1/2" 1/2"

GENERAL NOTES:

A. CONTRACTOR SHALL FIELD-VERIFY ALL DIMENSIONS PROVIDED FOR INTEGRAL SINK FABRICATION TO ENSURE COMPATIBILITY WITH BASE CABINETS AT EACH INSTALLATION SITE. VERIFIED DIMENSIONS SHALL BE INCORPORATED INTO THE SHOP DRAWINGS. ANY DISCREPANCIES OR CONFLICTS IDENTIFIED DURING VERIFICATION SHALL BE PROMPTLY REPORTED TO THE ARCHITECT AND OWNER FOR REVIEW AND DIRECTION.

B. WHERE SINKS AND TRIM ARE TO BE REPLACED AT QUARTZ COUNTERTOP LOCATIONS, CONTRACTOR SHALL FIELD-VERIFY THAT EXISTING COUNTERTOP OPENINGS CAN ACCOMMODATE THE NEW SINK AND TRIM COMPONENTS.

ANY INCOMPATIBILITIES SHALL BE REPORTED TO THE ARCHITECT AND OWNER FOR EVALUATION AND RESOLUTION.

C. CONTRACTOR SHALL VERIFY THAT EXISTING GARBAGE DISPOSALS DESIGNATED FOR REINSTALLATION ARE COMPATIBLE WITH THE NEWLY INSTALLED SINK UNITS. IN THE EVENT OF ANY INCOMPATIBILITY OR CONFLICT, CONTRACTOR SHALL PROMPTLY NOTIFY THE ARCHITECT AND OWNER FOR REVIEW AND DIRECTION.

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. P100

PLUMBING FIXTURE SCHEDULE

ELECTRICAL PANELBOARD PER PLANS, SURFACE MOUNTED ON WALL

TAMPER-RESISTANT DUPLEX GFI RECEPTACLE, IN WALL @ 18", U.O.N.

TAMPER-RESISTANT DUPLEX RECEPTACLE IN WALL @ +18", U.O.N.

JUNCTION BOX

JUNCTION BOX WITH FLEXIBLE CONDUIT CONNECTION TO EQUIPMENT

CONDUIT IN ATTIC/WALL: DENOTES 3/4"C-2#12 AWG CU THWN, 1#12 CU GND, U.O.N.

CONDUIT IN FLOOR/U.G.: DENOTES 3/4"C-2#12 AWG CU THWN, 1#12 CU GND, U.O.N.

ELECTRICAL KEYNOTES: DENOTES KEYNOTE #1 OF NOTES ON SAME SHEET

ELECTRICAL SYMBOL LEGEND

NOTE: SOME SYMBOLS SHOWN MAY NOT APPLY TO THIS PROJECT

DIMENSIONS INDICATED ARE MEASURED TO CENTERLINE OF

ENCLOSURE, UNLESS OTHERWISE NOTED

CONDUIT RUN: DENOTES 3/4"C - 4 #12 AWG CU THWN + 1 #12 CU GND, U.O.N.

CONDUIT RUN: DENOTES 3/4"C - 5 #12 AWG CU THWN + 1 #12 CU GND, U.O.N.

CONDUIT RUN: DENOTES 3/4"C - 3 #12 AWG CU THWN + 1 #12 CU GND, U.O.N.

CIRCUIT HOME RUN: DENOTES PANEL A, CKT. #3, - 3/4"C. MINIMUM, U.O.N.

ELECTRICAL PANELBOARD PER PLANS, FLUSH MOUNTED IN WALL

DENOTES EXISTING CONDUIT RUN TO REMAIN

DENOTES EXISTING TO REMAIN, NO WORK U.O.N.

DENOTES NEW

(E)

(N)

SYMBOL DESCRIPTION

(E) SURFACE MOUNTED RACEWAY

A-3

J

J

CONDUIT RUN: DENOTES 1"C - 6 #12 AWG CU THWN + 1 #12 CU GND, U.O.N.

INDUSTRIAL GFCI 20A CORD REEL, HUBBELL #HBLI25123GF20R

ALL WORK SHOWN HEREIN SHALL COMPLY WITH THE CURRENT REGULATIONS OF THE

CALIFORNIA STATE FIRE MARSHAL, CALIFORNIA BUILDING CODE, TITLES 8 AND 19

THROUGH 24, SERVING UTILITY RULES AND ALL OTHER APPLICABLE STATE ORDINANCES.

NOTHING IN THESE PLANS OR SPECIFICATIONS SHALL BE INTERPRETED AS TO PERMIT

ANY WORK NOT IN CONFORMANCE WITH THESE CODES, RULES AND REGULATIONS.

WHERE WORK OF A GREATER DEGREE IS INDICATED IN THESE PLANS OR

SPECIFICATIONS, THAT REQUIREMENT SHALL GOVERN SUCH WORK.

GENERAL NOTES (TYPICAL)

CODES, RULES & REGULATIONS

1. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR THE EXACT

LOCATION OF ALL CEILING MOUNTED ELECTRICAL EQUIPMENT.

2. COORDINATE ALL ELECTRICAL WORK WITH OTHER TRADES WHOSE WORK WILL

IMPACT PLACEMENT OR CONNECTION OF ELECTRICALLY POWERED EQUIPMENT

REGARDLESS OF RESPONSIBILITY FOR SUPPLYING EQUIPMENT.

ALL MECHANICAL, PLUMBING, AND ELECTRICAL COMPONENTS SHALL BE ANCHORED AND

INSTALLED PER THE DETAILS ON THE CONSTRUCTION DOCUMENTS. THE FOLLOWING

COMPONENTS SHALL BE ANCHORED OR BRACED TO MEET THE FORCE AND

DISPLACEMENT REQUIREMENTS PRESCRIBED IN THE 2022 CBC, SECTIONS 1617A.1.18

THROUGH 1617A.1.26 AND ASCE 7-16 CHAPTERS 13, 26 AND 30.

1. ALL PERMANENT EQUIPMENT AND COMPONENTS.

2. TEMPORARY, MOVEABLE OR MOBILE EQUIPMENT THAT IS PERMANENTLY

ATTACHED (E.G. HARD WIRED) TO THE BUILDING UTILITY SERVICES SUCH AS

ELECTRICITY, GAS OR WATER. "PERMANENTLY ATTACHED" SHALL INCLUDE ALL

ELECTRICAL CONNECTIONS EXCEPT PLUGS FOR 110/220 VOLT RECEPTACLES

HAVING FLEXIBLE CABLE.

3. TEMPORARY, MOVABLE OR MOBILE EQUIPMENT WHICH IS HEAVIER THAN 400

POUNDS OR HAS A CENTER OF MASS LOCATED 4 FEET OR MORE ABOVE THE

ADJACENT FLOOR OR ROOF LEVEL THAT DIRECTLY SUPPORT THE COMPONENT

IS REQUIRED TO BE RESTRAINED IN A MANNER APPROVED BY DSA.

THE FOLLOWING MECHANICAL AND ELECTRICAL COMPONENTS SHALL BE POSITIVELY

ATTACHED TO THE STRUCTURE BUT NEED NOT DEMONSTRATE DESIGN COMPLIANCE

WITH THE REFERENCES NOTED ABOVE. THESE COMPONENTS SHALL HAVE FLEXIBLE

CONNECTIONS PROVIDED BETWEEN THE COMPONENT AND ASSOCIATED DUCTWORK,

PIPING, AND CONDUIT. FLEXIBLE CONNECTIONS MUST ALLOW MOVEMENT IN BOTH

TRANSVERSE AND LONGITUDINAL DIRECTIONS:

A. COMPONENTS WEIGHING LESS THAN 400 POUNDS AND HAVE A CENTER OF MASS

LOCATED 4 FEET OR LESS ABOVE THE ADJACENT FLOOR OR ROOF LEVEL THAT

DIRECTLY SUPPORT THE COMPONENT.

B. COMPONENTS WEIGHING LESS THAN 20 POUNDS, OR IN THE CASE OF

DISTRIBUTED SYSTEMS, LESS THAN 5 POUNDS PER FOOT, WHICH ARE

SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM A WALL.

THE ANCHORAGE OF ALL MECHANICAL, ELECTRICAL AND PLUMBING COMPONENTS

SHALL BE SUBJECT TO THE APPROVAL OF THE DESIGN PROFESSIONAL IN GENERAL

RESPONSIBLE CHARGE OR STRUCTURAL ENGINEER DELEGATED RESPONSIBILITY AND

ACCEPTANCE BY DSA. THE PROJECT INSPECTOR WILL VERIFY THAT ALL COMPONENTS

AND EQUIPMENT HAVE BEEN ANCHORED IN ACCORDANCE WITH THE ABOVE

REQUIREMENTS.

PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEM BRACING NOTE:

PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO

COMPLY WITH THE FORCES AND DISPLACEMENTS PRESCRIBED IN ASCE 7-16 SECTION

13.3 AS DEFINED IN ASCE 7-16 SECTION 13.6.5, 13.6.6, 13.6.7, 13.6.8; AND 2022 CBC, SECTIONS 1617A.1.24, 1617A.1.25, AND 1617A.1.26.

THE METHOD OF SHOWING BRACING AND ATTACHMENTS TO THE STRUCTURE FOR THE

IDENTIFIED DISTRIBUTION SYSTEM ARE AS NOTED BELOW. WHEN BRACING AND

ATTACHMENTS ARE BASED ON A PREAPPROVED INSTALLATION GUIDE (E.G., OSHPD OPM

FOR 2013 CBC OR LATER), COPIES OF THE BRACING SYSTEM INSTALLATION GUIDE OR

MANUAL SHALL BE AVAILABLE ON THE JOBSITE PRIOR TO THE START OF AND DURING

THE HANGING AND BRACING OF THE DISTRIBUTION SYSTEMS. THE STRUCTURAL

ENGINEER OF RECORD SHALL VERIFY THE ADEQUACY OF THE STRUCTURE TO SUPPORT

THE HANGER AND BRACE LOADS.

ELECTRICAL DISTRIBUTION SYSTEMS:

SHALL COMPLY WITH THE APPLICABLE OSHPD PRE-APPROVAL (OPM#) #OPM-0052-13,

"SEISMIC BRACING AND SUPPORT SYSTEMS"

MEP COMPONENT ANCHORAGE NOTE

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. E001ELECTRICAL SCHEDULES, LEGENDS, AND NOTES

A. ELECTRICAL FACILITIES SHOWN DASHED ARE EXISTING:

1. THOSE SHOWN LIGHTWEIGHT (FADED) SHALL REMAIN

AND REQUIRE MODIFICATION AS NOTED.

2. THOSE SHOWN HEAVYWEIGHT (DARK) REQUIRE

REMOVAL OR RELOCATION AS NOTED.

B. EXISTING ELECTRICAL FACILITIES AND CIRCUITING SHOWN ARE

BASED ON LIMITED RECORD DRAWINGS AND LIMITED SITE

VISITS. THE DRAWINGS MAY NOT ACCURATELY REPRESENT

ACTUAL EXISTING CONDITIONS IN THE FIELD. THE CONTRACTOR

SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND RING OUT

EXISTING CIRCUITS TO DETERMINE EXACT ROUTING.

DEMOLITION NOTES

GENERAL NOTES

A. EXISTING CIRCUITING IS BASED ON AS BUILT RECORD

DRAWINGS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING

CONDITIONS.

B. CONDUIT AND CONDUCTORS FOR NEW OUTLETS SHALL BE

CONCEALED, U.O.N.

C. PENETRATIONS THROUGH WALLS, CEILINGS, FLOORS, AND/OR

ROOFS SHALL BE SEALED.

D. ELECTRICAL FACILITIES HAVE BEEN INVESTIGATED AND

DETERMINED TO HAVE SUFFICIENT CAPACITY FOR THE ADDED

LOAD.

E. ADDED RECEPTACLES SHALL BE CONNECTED TO EXISTING

SPARE BREAKERS UNLESS OTHERWISE NOTED.

F. SET CORD REEL RECEPTACLE AT 6' 8" ABOVE FINISHED FLOOR.

ARTS

CLASSROOM

J3

(E) CULINARY

ARTS

CLASSROOM

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MOD.

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. E210BOWMAN HIGH SCHOOL - ELECTRICAL FLOOR PLAN

DEMOLITION ELECTRICAL FLOOR PLAN

SCALE: 1/8" = 1'-0"

NORTH

KEYNOTES

DISCONNECT AND REMOVE (E) SURFACE MOUNTED RECEPTACLE,

SURFACE MOUNTED RACEWAY AND CONDUCTORS BACK TO SOURCE.

PROVIDE (N) GFCI RECEPTACLE AT SAME LOCATION OF REMOVED

RECEPTACLE. PROVIDE CONDUIT AND CONDUCTORS FROM (E)

COUNTERTOP RECEPTACLE CONCEALED IN WALL.

(E) COUNTERTOP RECEPTACLE TO REMAIN.

ELECTRICAL FLOOR PLAN

SCALE: 1/8" = 1'-0"

R R

R R

R R

(E) PANEL 'DC'

(E) PANEL 'DB'

(E) PANEL 'DHE'

(E) CLASSROOM

(E) OFFICE (E) SUPPLY

(E) VESTIBULE

(E) CLASSROOM

(E) CULINARY

ARTS

CLASSROOM

1 1

1 1

1 1

(E) PANEL 'DA'

DHE-10 DHE-34

DHE-37DHE-35

DB-29 DB-31

DB-33 DB-35

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. E220CANYON HIGH SCHOOL - ELECTRICAL FLOOR PLAN

KEYNOTES

1 PROVIDE INDUSTRIAL CORD REEL, HUBBELL #HBLI25123GF20 AND CORD

REEL ENCLOSURE, HUBBELL #HBLIPRBOX. MOUNT CORD REEL PER

DETAIL ON SHEET E600. PROVIDE DUPLEX RECEPTACLE AND COVER

PLATE MOUNTED IN CORD REEL ENCLOSURE PER DETAIL ON SHEET E600

AND MANUFACTURERS INSTALLATION INSTRUCTIONS.

PROVIDE A TYPEWRITTEN CIRCUIT DIRECTORY AT PANELBOARD IN

ACCORDANCE WITH CEC ARTICLE 408.4(A). THE CONTRACTOR SHALL

DEVELOP AND PREPARE THE CIRCUIT IDENTIFICATION DESCRIPTION

BASED ON THE AS-BUILT CONDITION AND TURN OFF ANY SPARE

(UNUSED) CIRCUIT BREAKERS IN THE PANELBOARD.

ELECTRICAL FLOOR PLAN

SCALE: 1/8" = 1'-0"

R

R R

R R

R

(E) PANEL 'ELH'

(E) PANEL 'ELK'

(E) CULINARY

ARTS

CLASSROOM

(E)

LAUNDRY

(E)

STORAGE

(E)

OFFICE

ELH-35

ELH-38

ELH-37 ELH-39 ELH-41

ELH-42ELH-40

2 111

1 1 1

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. E230GOLDEN VALLEY HIGH SCHOOL - ELECTRICAL FLOOR PLAN

ELECTRICAL FLOOR PLAN

SCALE: 1/8" = 1'-0"

NORTH

KEYNOTES

1 PROVIDE INDUSTRIAL CORD REEL, HUBBELL #HBLI25123GF20 AND CORD

REEL ENCLOSURE, HUBBELL #HBLIPRBOX. MOUNT CORD REEL PER

DETAIL ON SHEET E600. PROVIDE DUPLEX RECEPTACLE AND COVER

PLATE MOUNTED IN CORD REEL ENCLOSURE PER DETAIL ON SHEET E600

AND MANUFACTURERS INSTALLATION INSTRUCTIONS.

PROVIDE A TYPEWRITTEN CIRCUIT DIRECTORY AT PANELBOARD IN

ACCORDANCE WITH CEC ARTICLE 408.4(A). THE CONTRACTOR SHALL

DEVELOP AND PREPARE THE CIRCUIT IDENTIFICATION DESCRIPTION

BASED ON THE AS-BUILT CONDITION AND TURN OFF ANY SPARE

(UNUSED) CIRCUIT BREAKERS IN THE PANELBOARD.

R R R R

(E) CLASSROOM

(E) CULINARY

ARTS

CLASSROOM

(E) STORAGE

(E)

LAUNDRY

(E) PANEL 'LB2'(E) PANEL 'LB1'

1 1 1 1

2 3

LB2-16LB2-14LB2-15

LB2-13

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. E240VALENCIA HIGH SCHOOL - ELECTRICAL FLOOR PLAN

ELECTRICAL FLOOR PLAN

SCALE: 1/8" = 1'-0"

NORTH

KEYNOTES

1 PROVIDE INDUSTRIAL CORD REEL, HUBBELL #HBLI25123GF20 AND CORD

REEL ENCLOSURE, HUBBELL #HBLIPRBOX. MOUNT CORD REEL PER

DETAIL ON SHEET E600. PROVIDE DUPLEX RECEPTACLE AND COVER

PLATE MOUNTED IN CORD REEL ENCLOSURE PER DETAIL ON SHEET E600

AND MANUFACTURERS INSTALLATION INSTRUCTIONS.

PROVIDE A TYPEWRITTEN CIRCUIT DIRECTORY AT PANELBOARD IN

ACCORDANCE WITH CEC ARTICLE 408.4(A). THE CONTRACTOR SHALL

DEVELOP AND PREPARE THE CIRCUIT IDENTIFICATION DESCRIPTION

BASED ON THE AS-BUILT CONDITION AND TURN OFF ANY SPARE

(UNUSED) CIRCUIT BREAKERS IN THE PANELBOARD.

PROVIDE FOUR (4) NEW 20A, 1-POLE CIRCUIT BREAKERS IN PANEL 'LB2'

FOR PROTECTION OF NEW CORD REELS.

R

R R R

RR

R

(E) CULINARY

ARTS

CLASSROOM

(E) UTILITY

ROOM

(E)

STORAGE

(E)

OFFICE

(E) PANEL 'ELH'

(E) PANEL 'ELK'

1ELH-35

ELH-33ELH-31ELH-29

ELH-27

ELH-34ELH-32

1 1 1

ELH-30

ELH-36

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. E250WEST RANCH HIGH SCHOOL - ELECTRICAL FLOOR PLAN

ELECTRICAL FLOOR PLAN

SCALE: 1/8" = 1'-0"

NORTH

KEYNOTES

1 PROVIDE INDUSTRIAL CORD REEL, HUBBELL #HBLI25123GF20 AND CORD

REEL ENCLOSURE, HUBBELL #HBLIPRBOX. MOUNT CORD REEL PER

DETAIL ON SHEET E600. PROVIDE DUPLEX RECEPTACLE AND COVER

PLATE MOUNTED IN CORD REEL ENCLOSURE PER DETAIL ON SHEET E600

AND MANUFACTURERS INSTALLATION INSTRUCTIONS.

PROVIDE A TYPEWRITTEN CIRCUIT DIRECTORY AT PANELBOARD IN

ACCORDANCE WITH CEC ARTICLE 408.4(A). THE CONTRACTOR SHALL

DEVELOP AND PREPARE THE CIRCUIT IDENTIFICATION DESCRIPTION

BASED ON THE AS-BUILT CONDITION AND TURN OFF ANY SPARE

(UNUSED) CIRCUIT BREAKERS IN THE PANELBOARD.

R R R R

(E) CULINARY

ARTS

CLASSROOM

(E) HEATER

(E)

LAUNDRY

(E)

TOILET

(E)

JAN

(E)

ENTRY

(E)

OFFICE

(E) SEWING

(E)

CLASSROOM

(E) PANEL 'B'

(E) PANEL 'B1'

1 1 1 1

2 3

B1-32 B1-34 B1-36 B1-31

B1-33 B1-35

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. E260WILLIAM S. HART HIGH SCHOOL - ELECTRICAL FLOOR PLAN

ELECTRICAL FLOOR PLAN

SCALE: 1/8" = 1'-0"

NORTH

KEYNOTES

1 PROVIDE INDUSTRIAL CORD REEL, HUBBELL #HBLI25123GF20 AND CORD

REEL ENCLOSURE, HUBBELL #HBLIPRBOX. MOUNT CORD REEL PER

DETAIL ON SHEET E600. PROVIDE DUPLEX RECEPTACLE AND COVER

PLATE MOUNTED IN CORD REEL ENCLOSURE PER DETAIL ON SHEET E600

AND MANUFACTURERS INSTALLATION INSTRUCTIONS.

PROVIDE A TYPEWRITTEN CIRCUIT DIRECTORY AT PANELBOARD IN

ACCORDANCE WITH CEC ARTICLE 408.4(A). THE CONTRACTOR SHALL

DEVELOP AND PREPARE THE CIRCUIT IDENTIFICATION DESCRIPTION

BASED ON THE AS-BUILT CONDITION AND TURN OFF ANY SPARE

(UNUSED) CIRCUIT BREAKERS IN THE PANELBOARD.

REMOVE (E) 20A, 2-POLE CIRCUIT BREAKER ON CIRCUIT 33 & 35 AND 30A,

2-POLE CIRCUIT BREAKER ON CIRCUIT 34 & 36 AND RETURN TO DISTRICT.

PROVIDE FOUR (4) NEW 20A, 1-POLE CIRCUIT BREAKERS IN THE SAME

SPACES.

20A CORD REEL WITH

GFCI MODULE, HUBBELL

#HBLI25123GF20

CORD REEL ENCLOSURE,

HUBBELL #HBLIPRBOX

3/8" THREADED ROD. SECURE ENCLOSURE

TO THREADED ROD WITH TWO WASHERS

AND HEX NUTS, ONE WASHER AND NUT

ON EACH SIDE OF BRACKET. ATTACH

THREADED ROD AND LATERAL BRACING

TO STRUCTURE ABOVE (TYPICAL OF 4)

PER A803 AND A804.

ATTACH OUTLET BOX WITH #

8-32 NUTS TO ENCLOSURE

STUDS (TIGHTEN TO 16 IN/LB)

PROVIDE DUPLEX RECEPTACLE

AND FACEPLATE IN OUTLET

BOX. PROVIDE POWER

CONNECTION TO RECEPTACLE.

ATTACH CORD REEL TO

ENCLOSURE BRACKET

WITH PROVIDED NUTS

(TIGHTEN TO 20 IN/LB MIN)

(E) CEILING GRIDS AND PANELS

PROVIDE ROD STIFFENER,

(TYPICAL OF 4)

MAX STRUT

STIFFENER LENGTH

MAX UCC

SPACING

57"

48"

156" 28"

ROD

SIZE

3/4"

5/8"

3/8"

38"1/2" 156"

156"

156"

THREADED ROD

1-5/8"x1-5/8"x12

GA SINGLE STRUT

STIFFENER.

1/2"x1-1/2"x13 UNC

LOCKING BOLT

TORQUED TO 10

FT/LBS.

M A

X

T Y

P

M A

X

T Y

P

O

.C

M A

X

MASON IND. N.Y. UCC

SEISMIC ROD CLAMP.

PROJECT #:25-13283 DATE: 09/26/25

CULINARY ARTS CLASSROOM MODERNIZATION

WILLIAM S. HART UNION HIGH SCHOOL DISTRICT

VALENCIA, CA. E600ELECTRICAL DETAILS

CORD REEL DETAIL

SCALE: N.T.S.

ROD STIFFENER

SCALE: N.T.S.

GENERAL
G000 - COVER PAGE
G001 - GENERAL NOTES AND GOVERNING CODES
ARCHITECTURAL
A000 - ABBREVIATIONS
A100 - SITE PLANS
A210 - BOWMAN HIGH SCHOOL - FLOOR PLAN
A220 - CANYON HIGH SCHOOL - FLOOR PLAN
A225 - CANYON HIGH SCHOOL - REFLECTED CEILING PLAN
A230 - GOLDEN VALLEY HIGH SCHOOL - FLOOR PLAN
A235 - GOLDEN VALLEY HIGH SCHOOL - REFLECTED CEILING PLAN
A240 - VALENCIA HIGH SCHOOL - FLOOR PLAN
A245 - VALENCIA HIGH SCHOOL - REFLECTED CEILING PLAN
A250 - WEST RANCH HIGH SCHOOL - FLOOR PLAN
A255 - WEST RANCH HIGH SCHOOL - REFLECTED CEILING PLAN
A260 - WILLIAM S. HART HIGH SCHOOL - FLOOR PLAN
A265 - WILLIAM S. HART HIGH SCHOOL - REFLECTED CEILING PLAN
A800 - DETAILS

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .