2a. Appendix A - Site Plan A101.pdf
PDF 696 KB Posted
- Attached to
- Video Wall Replacement System and Support Federal contract opportunity
- Solicitation number
- 1305M220QNCNR0222
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment A - SOW for Video Display dtd Jul 28 2020.pdf | ||
| 1305M220QNCNR0222 - Amendment 0002.pdf | ||
| 1305M220QNCNR0222 - Amendment 0001.pdf | ||
| 2c. Appendix B - Site Photos.jpg | JPG image | |
| 2. Attachment A - SOW for Video Display.pdf | ||
| 2b. Appendix A - Site Plan E101.pdf | ||
| 3. Attachment B - Schedule of Supplies Services.docx | DOCX document | |
| 1. 1305M2-20-Q-NCNR0222.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. CONTRACTOR TO FIELD VERIFY ALL MEASUREMENTS
AND CONDITIONS NEW AND EXISTING. NOTIFY THE
ARCHITECT/OWNER'S REPRESENTATIVE OF ANY
DISCREPANCIES.
2. ENLARGED PLANS MAY BE ROTATED OR MIRRORED
COORDINATE WITH MAIN FLOOR PLAN.
3. ALL DIMENSIONS ARE TO THE FACE OF WALL OR
COLUMN CENTERLINES, UNLESS OTHERWISE NOTED.
4. CONTRACTOR TO PROVIDE 3/4" THICK PLYWOOD
BACKER BOARD, 4'-0" HIGH, IN ALL MECHANICAL AND
ELECTRICAL ROOMS MOUNTED 3'-6" A.F.F. FOR PERIMETER
OF ROOM.
5. PROVIDE MOLD RESISTANT GYPSUM BOARD AT ALL
EXTERIOR WALLS.
6. PROVIDE METAL TRIM OR CASING AT ALL EDGES OF
PLASTER AND DRYWALL SURFACES WHERE IT TERMINATES
OR MEETS ANY OTHER MATERIAL, UNLESS NOTED
OTHERWISE
7. PROVIDE METAL CORNER BEADS AT ALL OUTSIDE
CORNERS OF DRYWALL SURFACES, UNLESS NOTED
OTHERWISE.
8. CONTRACTOR TO PROVIDE WOOD BLOCKING BEHIND
ALL TOILET ROOM ACCESSORIES, GRAB BARS, WOOD TRIM,
AND WALL MOUNTED FIXTURES.
GENERAL NOTES:
REF.
REF.
C R
CR
C R
C R
CR
C R
CR
FD
FD
FD
FD
FD
FD
CR
C R
A201A3
A201
A201
A201
E3
H3
M3
C
E
F
G
H
J
K
L
92 3 4 5 6 7 8
Office
Office
Office
Office
Office
Office
Office
Office
Reception / Security
100A
Mech.
Copy
Storage
Office
Office
Office
Training / Conference
Women's
Men's
Office
Office
Mud Room
Shower
141A
Shower
141B
Cubby Room
Pump Room
Copy / Storage
Beverage Cntr
Breakout
Breakout
Breakout
Breakout
Incident Command
Center
Communication Center
Storage
Mech. Rm Electrical / Fire
Command
Server Room
Command / Control
Room
Recieving
Lobby
Open Office
Corridor
127B
Office
Office
Office
Break Room
Toilet
Toilet
Janitor
Corridor
127A
South Corridor
122A
North Corridor
122B
A1
A331
A14
A331
1' - 3 5/8" 6 3/8" 17' - 1" 9' - 7" 12' - 3" 9' - 9" 9' - 1" 17' - 1" 15' - 6" 10' - 8" 6 3/8" 1' - 3 5/8"
104' - 8"
26' - 8" 16' - 8" 5' - 4" 4' - 8" 4' - 0" 1' - 4" 4' - 0" 9' - 4" 4' - 0" 1' - 4" 4' - 0" 9' - 4" 4' - 0" 1' - 4" 4' - 0" 4' - 8" 5' - 4" 15' - 4"
125' - 4"
28' - 6" 12' - 3" 9' - 9" 9' - 1" 17' - 1" 15' - 6" 10' - 8" 22' - 6"
5' - 9" 8' - 11 1/8" 9' - 4" 9' - 4" 9' - 4" 9' - 4" 9' - 4" 5' - 9" 13' - 5 7/8"
21' - 7 1/2" 51' - 5" 10' - 10 3/4"
7' - 9 1/4" 9' - 10"
5' - 9" 14' - 4" 14' - 5" 14' - 6" 12' - 4 1/8" 5' - 9"
7' - 11 7/8" 34' - 9 7/8" 8' - 0" 7 1/4" 11' - 5 5/8"
2 3/4" 4' - 5 1/4"
3' - 4"
A402
A1
A401
A1
H1
A301
A1
A301
A1
A301
A9
A331
135/1
135/2
128/2 128/1
103/1
102/1
101/1
127A/1
121/1
123/1
117/1
111/1
112/1
113/1
141/1
141/2
141B/1
140/1139/1
144/1
145/1
145/2
127B/1
126/2
126/1
129/1
131/1
133/1
122B/1
138/1
138/2
114/1
110/1 107/1 106/1
118/1 119/1 120/1
105/1
104/1
109/1 108/1
116/1
141A/1
122A/1
115/1
142/1
130/1
132/1
134/1
124A/1
136/2
136/1
137/1
128/3
Restroom Vestibule
124A
39' - 11 3/4" 7' - 8 1/2" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 7' - 8 1/2" 11' - 8 3/4"
5' - 9" 2' - 6" 5' - 10" 5' - 1 7/8"
A241J1
A1
A1
A332
A5
A332
A242
D5
A242
H3
A241
A9
F1
J11 M11
A5
A332
SIM
A453
A1
A452
A1
A451
L1
I.1
I.1
I.1
I.1
A451
L5
D
H.8
K6
A332
124A/2
M
51' - 4"
9' - 0" 16' - 0" 16' - 0" 7' - 7 3/4"
A243
F1
100/1
122B/2
122A/2
3/4" PLYWOOD (06100)
3' AFF. FULL
PERIMETER OF ROOM
P
N
B
A
M.1
N.1
A242
A1
A5 A242 A5
SI
M
A351
G9
Electrical Room
145A
145A/1
A242D1
K1
FE-1
FE-1
FE-1
SOFFIT ABOVE
K7
A5
A331
SIM
10"
4" HIGH CONCRETE
PAD FOR
COLLECTION TANK
A021
F6
V-WHEEL ROLLING GATE
(02086)
SWING GATE "SINGLE" (02086)
6" 4' - 0"
2' - 4 3/4"
L201
M1
A243
A1
L201J1
5' - 11 3/4"
METAL FABRICATIONS (05500)
HEATING, VENTILATING, AND
AIR CONDITIONING
EQUIPMENT (RE: MEP)
WALK OFF MAT (09681)
A12
A351
PNT-3
PNT-3
P N
T
PNT-4
P N
T
P N
T
CONCRETE SLAB (03300)
100/2
FE-2
FE-2
I.1
Fax: (816) 358-2367 www.gdsengr.com
Gibbens Drake Scott, Inc.
Phone: (816) 358-1790
Raytown, Missouri 64133
9201 E. 63rd Street, Suite 100
Project No
Date:
Sheet:
U.S. Department of Commerce, NOAA
Prime Consultant - MEP FP Engineer:
GDS Engineering
9201 E. 63rd Street, Suite 100
Raytown, MO 64133
Tel. 816-358-1790
Fax. 816-358-2367
Architect of Record:
Gould Evans Associates, LC
4041 Mill Street
Kansas City, Missouri 64111
P: 816-931-6655
F: 816 931 9640
Civil/Structural Engineer:
TranSystems
2400 Pershing Road, Suite 400
Kansas City, MO 64108
P: 816.329.8600
F: 816.329.8602
2 13456789101112131415161718
A
B
C
D
E
F
G
H
J
K
L
M
N
P
A
B
C
D
E
F
G
H
J
K
L
M
N
P
2 13456789101112131415161718
A101
Number Revision Description Date
1/8" = 1'-0" A9 / A021
A3
AS BUILT 01-26-2015
File details come from the government source that posted it. Updated .