13-IFB 26-1-23301 Vol.5B Plans Drawings.pdf
PDF 24 MB Posted
- Solicitation number
- 26-1-23301
- Issued by
- Lasalle County, Illinois
About this file
This document is a set of architectural floor plans and door schedules for multiple Madison County Transit (MCT) facilities in Illinois, specifically covering sites in Wood River (WRTC), Granite City (GCTC), Collinsville (CTC), and Edwardsville (ETC). The project, identified as MCT #26-1-23301, involves upgrades to security and door hardware systems, with an issuance date of 10-10-2025, and is not intended for construction but rather for invitation for bid (IFB) purposes. The plans detail existing floor layouts, door configurations, and proposed modifications including new door hardware, electrified hardware, power assist operators, and associated components.
The project is federally funded by the Federal Transit Administration (USDOT) and requires compliance with Buy America regulations, Equal Employment Opportunity laws, Davis-Bacon Act prevailing wage rates, and Disadvantaged Business Enterprise (DBE) participation goals. The project has established a DBE participation goal of 0.17% of the awarded contract sum. The scope includes security improvements across multiple transit properties, with comprehensive upgrades to access control and video surveillance systems. Contractors will be required to coordinate electrical work, replace existing hardware, and ensure compatibility with current infrastructure while meeting federal funding requirements.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
100B
WAITING
MECH.
JAN.
VESTIBULE
VESTIBULE
X 100B
104B
X 104B
JAN.
I.T.
X 100A
100A
104A
X 104A
MAINT./ EQUIP.
WOMEN
MENX202
X200
X2
2"
SEE SCHED.
2"
2"
2"
SEE SCHED.
2"
4"
A B
S E
E S
C H
E D
S E
E S
C H
E D
SEE SCHED.
C
S E
E S
C H
E D
8' -8
8'-0"
HOLLOW METAL
DOOR
STOREFRONT
DOOR
SEE SCHED.
S E
E S
C H
E D
SEE SCHED.
S E
E S
C H
E D
MCT #26-1-23301
10-10-2025
U P
G R
A D
E S t o
S E
C U
R
IT
Y a n d
D O
O R
H A
R D
W A
R E
S Y
S T
E M
S M
A D
IS
O
N C
O U
N T
Y T
R A
N S
IT
M U
L T
IP
L E
S
IT
E S
M A
D
IS
O N
C O
U N
T Y
L
L
IN
O
IS
NOT FOR
CONSTRUCTION
PROJECT:
ISSUANCE:
ISSUED FOR IFB 100% PLANS
# DATE DESCRIPTION
B
A
D
C
E
B
A
D
C
E
21 3 4 5 6
REVISIONS:
DATE:
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET NO:
SHEET TITLE:
R
T M e n gi ne er in g c o ns u lta n ts
21 3 4 5 6
GR
WRTC-A1
NC/MS
EXISTING FLOOR
PLAN - WRTC
1/4" = 1'-0"
EXISTING GROUND FLOOR PLAN - WRTC
1/4" = 1'-0"
EXISTING GROUND FLOOR PLAN - WRTC-DETACH
TRUE NORTHPLAN NORTH
EXISTING DOOR SCHEDULE - WOOD RIVER (WRTC)
NUMBER EXISTING/NEW
SIZE DOOR FRAME
HDW. CLIENT CommentsWIDTH HEIGHT THICKNESS MATERIAL FINISH EL. MATERIAL FINISH EL.
100A EXISTING 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. A 1.2
100B EXISTING 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. A 1.2
101 EXISTING 3' - 0" 7' - 0" 0' - 2" HM PT 1 HM PT A 2
102 EXISTING 3' - 0" 7' - 0" 0' - 2" HM PT 1 HM PT A 2
104A EXISTING 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. A 1.3 REPLACE POWER ASSIST OPERATOR AND COMPONENTS
104B EXISTING 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. A 1.3 REPLACE POWER ASSIST OPERATOR AND COMPONENTS
105 EXISTING 3' - 0" 7' - 0" 0' - 2" HM PT 1 HM PT A 2
106 EXISTING 3' - 0" 7' - 0" 0' - 2" HM PT 1 HM PT A 2
200 NEW 3' - 0" 7' - 0" 0' - 2" HM PT 1 HM PT B 2
201 NEW 3' - 0" 7' - 0" 0' - 2" HM PT 1 HM PT B 3
202 NEW 3' - 0" 7' - 0" 0' - 2" HM PT 1 HM PT B 3
X100A EXISTING 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. C 1
X100B EXISTING 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. C 1
X104A EXISTING 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. C 1.1 REPLACE POWER ASSIST OPERATOR AND COMPONENTS
X104B EXISTING 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. C 1.1 REPLACE POWER ASSIST OPERATOR AND COMPONENTS
1/4" = 1'-0"
EXISTING DOOR FRAMES (WRTC)
1/4" = 1'-0"
EXISTING DOOR ELEVATIONS (WRTC)
GENERAL NOTES
SHEET KEY NOTES
1 EXISTING DOOR TO RECEIVE NEW DOOR
HARDWARE (HINGES, LOCKSET, EXIT
DEVICE, THRESHOLD, CLOSURE, ETC. - SEE
DOOR HARDWARE SPECIFICATIONS).
2 EXISTING DOOR TO RECEIVE NEW
ELECTRIFIED DOOR HARDWARE. SEE
ELECTRICAL PLANS AND DOOR HARDWARE
SPECIFICATIONS.
3 REMOVE AND REPLACE DOOR AND FRAME.
4 EXISTING DOOR TO RECEIVE NEW POWER
ASSIST OPERATOR COMPONENTS (PUSH
PADS, OPENER, WIRING, ETC)
1. CONTRACTOR TO COORDINATE WITH
ELECTRICAL DRAWINGS FOR SCOPE OF
ELECTRIFIED HARDWARE.
LOBBY
MEN'S
WOMEN'S
X104
X103
0A
X10 0A
VESTIBULE
OFFICE
ALCOVE
CLOSET
ROOM
CONDENSING
UNITS
JAN.
MECH.
108A
108A
I.T.
X
X10 0B
0B
C
C
C
HOLLOW METAL
DOOR
STOREFRONT
DOOR
STOREFRONT
DOOR
SOLID CORE
WOOD DOOR
SEE SCHED.
S E
E S
C H
E D
SEE SCHED.
S E
E S
C H
E D
SEE SCHED.
S E
E S
C H
E D
SEE SCHED.
S E
E S
C H
E D
2"
SEE SCHED.
2"
2"
A
S E
E S
C H
E D
5' -4
1'
-8
5' -4
1'
-8
DC
SEE SCHED.
B
SEE SCHED. SEE SCHED.
S
E E
S C
H E
D
8' -8
8' -8
7'-0"
S E
E S
C H
E D
14'-7"
8' -8
S E
E S
C H
E D
MCT #26-1-23301
10-10-2025
U P
G R
A D
E S t o
S E
C U
R
IT
Y a n d
D O
O R
H A
R D
W A
R E
S Y
S T
E M
S M
A D
IS
O
N C
O U
N T
Y T
R A
N S
IT
M U
L T
IP
L E
S
IT
E S
M A
D
IS
O N
C O
U N
T Y
L
L
IN
O
IS
NOT FOR
CONSTRUCTION
PROJECT:
ISSUANCE:
ISSUED FOR IFB 100% PLANS
# DATE DESCRIPTION
B
A
D
C
E
B
A
D
C
E
21 3 4 5 6
REVISIONS:
DATE:
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET NO:
SHEET TITLE:
R
T M e n gi ne er in g c o ns u lta n ts
21 3 4 5 6
GR
GCTC-A1
NC/MS
EXISTING FLOOR
PLAN - GCTC
1/4" = 1'-0"
EXISTING GROUND FLOOR PLAN - GCTC
TRUE NORTHPLAN NORTH
EXISTING DOOR SCHEDULE - GRANITE CITY (GCTC)
NUMBER EXISTING/NEW
SIZE DOOR FRAME
HDW. CLIENT COMMENTSWIDTH HEIGHT Thickness MATERIAL FINISH EL. MATERIAL FINISH EL.
100A EXISTING 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. B 1.2 RETURN EXISTING CARD READER TO OWNER
100B EXISTING 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. B 1.2 RETURN EXISTING CARD READER TO OWNER
101 EXISTING 3' - 0" 7' - 0" 0' - 2" WOOD S&V 5 HM PT A 3.1
102 EXISTING 3' - 0" 7' - 0" 0' - 2" WOOD S&V 5 HM PT A 3.1
104 EXISTING 3' - 0" 7' - 0" 0' - 2" WOOD S&V 5 HM PT A 2 RETURN EXISTING CARD READER TO OWNER
105 EXISTING 3' - 0" 7' - 0" 0' - 2" WOOD S&V 5 HM PT A 2 RETURN EXISTING CARD READER TO OWNER
106 EXISTING 3' - 0" 7' - 0" 0' - 2" WOOD S&V 5 HM PT A 2.1
107 EXISTING 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. A 4 RETURN EXISTING CARD READER TO OWNER
108 EXISTING 3' - 0" 7' - 0" 0' - 2" WOOD S&V 5 HM PT A 4 RETURN EXISTING CARD READER TO OWNER
108A EXISTING 3' - 10" 7' - 0" 0' - 1 3/4" WOOD S&V 5 HM PT A NO WORK
X100A EXISTING 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. D 1 RETURN EXISTING CARD READER TO OWNER
X100B EXISTING 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. D 1 RETURN EXISTING CARD READER TO OWNER
X103 EXISTING
3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. C 1.1 RETURN EXISTING CARD READER TO OWNER; REPLACE POWER ASSIST
COMPONENTS
X104 NEW 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 1 ALUM. ANOD. B 5 RETURN EXISTING CARD READER TO OWNER
X107 NEW 3' - 0" 7' - 0" 0' - 1 3/4" ALUM. ANOD. 1 ALUM. ANOD. A 1 RETURN EXISTING CARD READER TO OWNER1/4" = 1'-0"
EXISTING DOOR ELEVATIONS (GCTC)
1/4" = 1'-0"
EXISTING DOOR FRAMES (GCTC)
GENERAL NOTES
SHEET KEY NOTES
1. CONTRACTOR TO COORDINATE WITH
ELECTRICAL DRAWINGS FOR SCOPE OF
ELECTRIFIED HARDWARE.
1 EXISTING DOOR TO RECEIVE NEW DOOR
HARDWARE (HINGES, LOCKSET, EXIT
DEVICE, THRESHOLD, CLOSURE, ETC. - SEE
DOOR HARDWARE SPECIFICATIONS).
2 EXISTING DOOR TO RECEIVE NEW
ELECTRIFIED DOOR HARDWARE. SEE
ELECTRICAL PLANS AND DOOR HARDWARE
SPECIFICATIONS.
3 REMOVE AND REPLACE DOOR AND FRAME.
4 EXISTING DOOR TO RECEIVE NEW POWER
ASSIST OPERATOR COMPONENTS (PUSH
PADS, OPENER, WIRING, ETC)
WAITING AREA
MECH./ELEC.
M.
W.
103104
X
1A
X
1B
X
1D
X
1C
1 4
2 2
HOLLOW METAL
DOOR
STOREFRONT
DOOR
S E
E S
H C
E D
SEE SCHED. SEE SCHED.
S E
E S
C H
E D
2"
SEE SCHED.
2"
2"
2"
SEE SCHED.
2"
A B
S E
E S
C H
E D
12'-8"
3' -0
4'
-8 "13
'-0
S E
E S
C H
E D
MCT #26-1-23301
10-10-2025
U P
G R
A D
E S t o
S E
C U
R
IT
Y a n d
D O
O R
H A
R D
W A
R E
S Y
S T
E M
S M
A D
IS
O
N C
O U
N T
Y T
R A
N S
IT
M U
L T
IP
L E
S
IT
E S
M A
D
IS
O N
C O
U N
T Y
L
L
IN
O
IS
NOT FOR
CONSTRUCTION
PROJECT:
ISSUANCE:
ISSUED FOR IFB 100% PLANS
# DATE DESCRIPTION
B
A
D
C
E
B
A
D
C
E
21 3 4 5 6
REVISIONS:
DATE:
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET NO:
SHEET TITLE:
R
T M e n gi ne er in g c o ns u lta n ts
21 3 4 5 6
GR
CTC-A1
NC/MS
EXISTING FLOOR
PLAN - CTC1/4" = 1'-0"
EXISTING GROUND FLOOR PLAN - CTC
TRUE NORTHPLAN NORTH
EXISTING DOOR SCHEDULE - COLLINSVILLE (CTC)
NUMBER EXISTING/ NEW
SIZE DOOR FRAME
HDW.
CLIENT COMMENTS
WIDTH HEIGHT THICKNESS MATERIAL FINISH EL. MATERIAL FINISH EL.
102 EXISTING 3' - 0" 6' - 10" 0' - 1 3/4" HM PT 1 HM PT A 3
103 EXISTING 3' - 0" 6' - 10" 0' - 1 3/4" HM PT 1 HM PT A 3
104 EXISTING 3' - 0" 6' - 10" 0' - 1 3/4" HM PT 1 HM PT A 2
X101A EXISTING 3' - 0" 7' - 8" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. B 1.1 REPLACE POWER ASSIST OPERATOR AND COMPONENTS
X101B EXISTING 3' - 0" 7' - 8" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. B 1.1 REPLACE POWER ASSIST OPERATOR AND COMPONENTS
X101C EXISTING 3' - 0" 7' - 8" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. B 1.1 REPLACE POWER ASSIST OPERATOR AND COMPONENTS
X101D EXISTING 3' - 0" 7' - 8" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. B 1.1 REPLACE POWER ASSIST OPERATOR AND COMPONENTS
1/4" = 1'-0"
EXISTING DOOR ELEVATIONS (CTC)
1/4" = 1'-0"
EXISTING DOOR FRAMES (CTC)
GENERAL NOTES
SHEET KEY NOTES
1 EXISTING DOOR TO RECEIVE NEW DOOR
HARDWARE (HINGES, LOCKSET, EXIT
DEVICE, THRESHOLD, CLOSURE, ETC. - SEE
DOOR HARDWARE SPECIFICATIONS).
2 EXISTING DOOR TO RECEIVE NEW
ELECTRIFIED DOOR HARDWARE. SEE
ELECTRICAL PLANS AND DOOR HARDWARE
SPECIFICATIONS.
3 REMOVE AND REPLACE DOOR AND FRAME.
4 EXISTING DOOR TO RECEIVE NEW POWER
ASSIST OPERATOR COMPONENTS (PUSH
PADS, OPENER, WIRING, ETC)
1. CONTRACTOR TO COORDINATE WITH
ELECTRICAL DRAWINGS FOR SCOPE OF
ELECTRIFIED HARDWARE.
MECH.
JANITOR
WOMEN'S
MEN'S
CORRIDOR
103D
CLO.
103B
CLO.
103C
CLO.
103A
CLO.
MEN'S
WOMEN'S
VESTIBULE
VESTIBULE
WAITING AREA
109 110
X
103 103A
103D
103C
1B
X
1B
X
1A
X
1A
1 1
HOLLOW METAL
DOOR
STOREFRONT
DOOR
HOLLOW METAL
DOOR
SOLID CORE
WOOD DOOR
SEE SCHED. SEE SCHED. SEE SCHED. SEE SCHED.
S E
E S
C H
E D
S E
E S
C H
E D
S E
E S
C H
E D
S E
E S
C H
E D
2"
SEE SCHED.
2"
2"
2"
SEE SCHED.
2"
4"
A B
S E
E S
C H
E D
S E
E S
C H
E D
C D E
SEE SCHED.
9'-8"
SEE SCHED.
10'-4"
9' -0
SEE SCHED.
11'-8"
9' -4
/4
SEE SCHED.
'-4
7'-0"
F
S E
E S
C H
E D
S E
E S
C H
E D
8' -8
S E
E S
C H
E D
S E
E S
C H
E D
MCT #26-1-23301
10-10-2025
U P
G R
A D
E S t o
S E
C U
R
IT
Y a n d
D O
O R
H A
R D
W A
R E
S Y
S T
E M
S M
A D
IS
O
N C
O U
N T
Y T
R A
N S
IT
M U
L T
IP
L E
S
IT
E S
M A
D
IS
O N
C O
U N
T Y
L
L
IN
O
IS
NOT FOR
CONSTRUCTION
PROJECT:
ISSUANCE:
ISSUED FOR IFB 100% PLANS
# DATE DESCRIPTION
B
A
D
C
E
B
A
D
C
E
21 3 4 5 6
REVISIONS:
DATE:
PROJECT NUMBER:
DRAWN BY: CHECKED BY:
SHEET NO:
SHEET TITLE:
R
T M e n gi ne er in g c o ns u lta n ts
21 3 4 5 6
GR
ETC-A1
NC/MS
EXISTING FLOOR
PLAN - ETC
1/4" = 1'-0"
EXISTING GROUND FLOOR PLAN - ETC
TRUE NORTHPLAN NORTH
DOOR SCHEDULE - EDWARDSVILLE (ETC)
NUMBER EXISTING/NEW
SIZE DOOR FRAME
HDW.
CLIENT COMMENTS
WIDTH HEIGHT THICKNESS MATERIAL FINISH EL. MATERIAL FINISH EL.
101 EXISTING 3' - 0" 7' - 2" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. F 1.3 REPLACE POWER ASSIST OPERATOR AND COMPONENTS
103 EXISTING 3' - 0" 7' - 0" 0' - 2" HM PT 1 HM PT A 4
103A EXISTING 3' - 0" 7' - 0" 0' - 1 3/4" WOOD S&V 4 HM PT A NO WORK
103C EXISTING 5' - 0" 7' - 0" 0' - 1 3/4" WOOD S&V 4 HM PT A NO WORK
103D EXISTING 4' - 0" 7' - 0" 0' - 1 3/4" WOOD S&V 4 HM PT A NO WORK
104 EXISTING 3' - 0" 7' - 0" 0' - 2" HM PT 1 HM PT A 4
105 EXISTING 3' - 0" 7' - 0" 0' - 2" HM PT 2 HM PT A 3.1
106 EXISTING 3' - 0" 7' - 0" 0' - 2" HM PT 2 HM PT A 3.1
107 EXISTING 3' - 0" 7' - 0" 0' - 2" HM PT 1 HM PT A 2
108 EXISTING 3' - 0" 7' - 0" 0' - 2" HM PT 1 HM PT A 2
109 EXISTING 3' - 0" 7' - 0" 0' - 2" HM PT 2 HM PT A 3.1
110 EXISTING 3' - 0" 7' - 0" 0' - 2" HM PT 2 HM PT A 3.1
111A EXISTING 3' - 0" 7' - 2" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. D 1.2
111B EXISTING 3' - 0" 7' - 2" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. D 1.2
X101 EXISTING 3' - 0" 7' - 2" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. C 1.1 REPLACE POWER ASSIST OPERATOR AND COMPONENTS
X104 EXISTING 3' - 0" 7' - 0" 0' - 2" HM PT 1 HM PT B 1
X111A EXISTING 3' - 0" 7' - 2" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. E 1
X111B EXISTING 3' - 0" 7' - 2" 0' - 1 3/4" ALUM. ANOD. 3 ALUM. ANOD. E 1
1/4" = 1'-0"
EXISTING DOOR ELEVATIONS (ETC)
1/4" = 1'-0"
EXISTING DOOR FRAMES (ETC)
GENERAL NOTES
SHEET KEY NOTES
1. CONTRACTOR TO COORDINATE WITH
ELECTRICAL DRAWINGS FOR SCOPE OF
ELECTRIFIED HARDWARE.
1 EXISTING DOOR TO RECEIVE NEW DOOR
HARDWARE (HINGES, LOCKSET, EXIT
DEVICE, THRESHOLD, CLOSURE, ETC. - SEE
DOOR HARDWARE SPECIFICATIONS).
2 EXISTING DOOR TO RECEIVE NEW
ELECTRIFIED DOOR HARDWARE. SEE
ELECTRICAL PLANS AND DOOR HARDWARE
SPECIFICATIONS.
3 REMOVE AND REPLACE DOOR AND FRAME.
4 EXISTING DOOR TO RECEIVE NEW POWER
ASSIST OPERATOR COMPONENTS (PUSH
PADS, OPENER, WIRING, ETC)
| 1- G-0 |
| 2- E-0 |
| 3- WRTC-DE1 |
| 4- WRTC-E1 |
| 5- WRTC-A1 |
| 6- EGPR-DE1 |
| 7- EGPR-E1 |
| 8- GCTC-DE1 |
| 9- GCTC-E1 |
| 10- GCTC-A1 |
| 11- CTC-DE1 |
| 12- CTC-E1 |
| 13- CTC-A1 |
| 14- ETC-DE1 |
| 15- ETC-E1 |
| 16- ETC-A1 |
| 17- EPR-DE1 |
| 18- EPR-E1 |
| 19- L-E1 |
| 20- TPR-DE1 |
| 21- TPR-E1 |
| 22- R3PR-DE1 |
| 23- R3PR-E1 |
| 24- GLPR-DE1 |
| 25- GLPR-E1 |
| 26- HPR-E1 |
File details come from the government source that posted it. Updated .