13-Design Plan HENDRICKSON HS TURF POND DESIGN - CIVIL PRICING SET.pdf

PDF 44 MB Posted

Attached to
Hendrickson High School and Weiss High School Baseball and Softball Turf Conversion
Solicitation number
CSP 26-024JO
Issued by
Travis County, Texas

About this file

This is a design plan document prepared by Civilitude LLC for the Pflugerville Independent School District detailing the turf field and pond design project at Hendrickson High School located at 19201 Colorado Sand Drive, Pflugerville, Texas. The project proposes to replace existing baseball and softball fields with artificial turf fields, install a drainage system for the proposed fields, and modify the existing detention pond. The site encompasses 9.04 acres within the Walberger Creek Watershed and is zoned as Agriculture/Development Reserve. The design plan was submitted on April 6, 2026, and includes 12 sheets covering existing conditions, demolition plans, site plans, erosion and sedimentation controls, drainage maps and calculations, detention pond details, construction details, and turf specifications. The project requires compliance with the Americans with Disabilities Act and has been submitted to the Texas Department of Licensing and Regulation (reference #2062612060) for review of compliance with the Architectural Barriers Act.

The design was prepared by Civil Engineer Jordan Miller, PE, of Civilitude LLC and has been recommended for approval by the City of Pflugerville Planning and Development Services. The site is not located within a flood hazard area according to the FEMA Flood Insurance Rate Map Panel #48453C0280J for Travis County (effective August 18, 2014). All contractors are required to field-verify utilities prior to construction commencement and to dispose of sediment control measures once permanent erosion control measures are established. The responsibility for adequacy of the plans remains with the engineer who prepared them, and the City of Pflugerville relies on the adequacy of the design engineer's work during plan review.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LOCATION MAP

SITE

HENDRICKSON HIGH SCHOOL

19201 COLORADO SAND DR, PFLUGERVILLE, TX 78660

SUBMITTAL DATE: 04/06/2026

TURF FIELD & POND DESIGN

FIRM REG# F-12469 503 KENNISTON DR., AUSTIN, TX 78752

PHONE: (512) 761-6161 FAX: (512) 761-6167 INFO@CIVILITUDE.COM

PFLUGERVILLE INDEPENDENT SCHOOL DISTRICT

1401 W PECAN ST.

PFLUGERVILLE, TX 78660

(512) 594-0000

CIVIL ENGINEER

JORDAN MILLER, PE

CIVILITUDE LLC

503 KENNISTON DR.

AUSTIN, TX 78752

(512) 761-6161

DATE

SUBMITTED BY

TOTAL SITE IMPERV.

COVER (SF AND %)

NET CHANGE IN

IMPERV. COVER (SF)

TOTAL # SHEETS

IN PLAN SET

REVISE (R) REPLACEMENT (RP)

ADD (A) VOID (V) SHEET #'S

CITY OF PFLUGERVILLE

SIGNATURE

CITY OF

PFLUGERVILLE

APPROVAL DATE

DESCRIPTION

CORRECTION/

REVISION

NUMBER

DESIGN TEAM

OWNER

CITY OF PFLUGERVILLE REVISIONS/CORRECTIONS TABLE

1. WATERSHED STATUS: THIS PROJECT IS LOCATED IN THE WALBERGER CREEK WATERSHED

(SUBURBAN).

2. SITE IS ZONED AS A - AGRICULTURE/DEVELOPEMENT RESERVE.

3. ALL RESPONSIBILITY FOR THE ADEQUACY OF THESE PLANS REMAINS WITH THE

ENGINEER WHO PREPARED THEM. IN REVIEWING THESE PLANS, THE CITY OF

PflUGERVILLE MUST RELY ON THE ADEQUACY OF THE WORK OF THE DESIGN ENGINEER.”

GENERAL PLAN NOTES

1. THESE PLANS ARE IN ACCORDANCE WITH THE FOLLOWING STUDIES/REPORTS:

2. THIS SITE PLAN HAS BEEN SUBMITTED TO THE TEXAS DEPARTMENT OF LICENSING AND

REGULATION FOR REVIEW OF COMPLIANCE WITH THE ARCHITECTURAL BARRIERS ACT. THE

REFERENCE #2062612060 IS PROOF OF SUBMITTAL TO TDLR.

3. THE CITY OF PFLUGERVILLE HAS NOT REVIEWED THESE PLANS FOR COMPLIANCE WITH THE

AMERICAN DISABILITIES ACT. ALL SIDEWALKS SHALL COMPLY WITH THE AMERICANS WITH

DISABILITIES ACT. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE COMPLIANCE WITH ALL

LEGISLATION RELATED TO ACCESSIBILITY WITHIN THE LIMITS OF CONSTRUCTION SHOWN IN

THERE PLANS.

4. ALL RESPONSIBILITY FOR THE ADEQUACY OF THESE PLANS REMAINS WITH THE ENGINEER WHO

PREPARED THEM. IN REVIEWING THESE PLANS, THE CITY OF PFLUGERVILLE MUST REPLY ON THE

ADEQUACY OF THE WORK OF THE DESIGN ENGINEER.

5. EXISTING SITE BUILDINGS ARE OUTSIDE THE SCOPE OF THE CURRENT PROJECT. EXISTING TYPE IS

E, PER IBC 2021. EXISING USE IS GOVERNMENT FACILITIES PER CITY OF PFLUGERVILLE UNIFIED

DEVELOPMENT CODE SUBCHAPTER 4.3.2.

SITE PLAN RELEASE NOTES

ABS 231 SUR 13 DAVIS J ACR 64.731

TBM#1: TEMPORARY BENCHMARK SET

MAG NAIL WITH SHINER IN ASPHALT

ELEVATION: 721.46'

TBM #2: TEMPORARY BENCHMARK SET

MAG NAIL WITH WASHER

STAMPED "SURVEY WORKS"

ELEVATION: 717.14'

BENCH MARK:

NO PORTION OF THIS TRACT IS WITHIN A

FLOOD HAZARD AREA AS DELINEATEED ON

THE FEMA FLOOD INSURANCE RATE MAP

PANEL# 48453C0280J FOR TRAVIS COUNTY,

EFFECTIVE DATE 08/18/2014

LEGAL DESCRIPTION

FLOOD STATEMENT

A

ZONING

PLANNING DIRECTOR

DEVELOPMENT ENGINEER DIRECTOR

RECOMMENDED FOR APPROVAL

CITY OF PFLUGERVILLE

PUBLIC WORKS DEPARTMENT

15500 SUN LIGHT NEAR WAY

PFLUGERVILLE, TX 78660

(512) 990-6400

CITY AND UTILITY CONTACT

CITY OF PFLUGERVILLE

PLANNING AND DEVELOPMENT SERVICES

100 W MAIN ST

PFLUGERVILLE, TX 78660

(512) 990-6300

WATER

CITY OF PFLUGERVILLE

15500 SUN LIGHT NEAR WAY, #B

PFLUGERVILLE, TX 78660

(512) 990-6400

ELECTRIC

ONCOR

350 TEXAS AVE

ROUND ROCK, TX 78664

(512) 244-5692

GAS

ATMOS MIDTX

3110 N I-35

ROUND ROCK, TX 78681

(817) 307-6069

WASTEWATER

CITY OF PFLUGERVILLE

15500 SUN LIGHT NEAR WAY

PFLUGERVILLE, TX 78660

(512) 990-6400

THIS PROJECT PROPOSES TO REPLACE THE EXISTING BASEBALL AND SOFTBALL FIELDS WITH

ARTIFICIAL TURF FIELDS. A DRAINAGE SYSTEM FOR THESE PROPOSED FIELDS AND MODIFICATION

OF THE EXISTING DETENTION POND ARE ALSO PROPOSED.

PROJECT NARRATIVE

SHEET INDEX

SHEET

NUMBER SHEET TITLE

01 COVER SHEET

02 GENERAL NOTES

03 EXISTING CONDITIONS & DEMOLITION

PLAN

04 SITE PLAN

05 EROSION, SEDIMENTATION, AND TREE

PROTECTION PLAN

06 EXISTING DRAINAGE MAP

07 PROPOSED DRAINAGE MAP

08 DRAINAGE AREA CALCULATIONS

09 GRADING & DRAINAGE PLAN

10 DETENTION POND DETAILS PLAN

11 CONSTRUCTION DETAILS

12 TURF DETAILS

04-06-2026

N 62°24'53" W

1,265.06'

S 27°37'07" W 122.98'

S 27°37'07" W 599.33'

N

NOTES:

1. CONTRACTOR TO FIELD VERIFY ALL UTILITIES PRIOR TO THE

COMMENCEMENT OF CONSTRUCTION.

LEGEND

BOUNDARY / RIGHT OF WAY

EASEMENT / SETBACK

CURB / EDGE OF PAVEMENT

PROPOSED BUILDING PAD AREA

STORM DRAIN LINE

WATER LINE

WASTEWATER LINE

WW

D

AC

WASTEWATER MANHOLE

WATER METER

WATER VALVE

FIRE HYDRANT

CO WASTEWATER CLEANOUT

BFP BACKFLOW PREVENTER

STORM DRAIN MANHOLE

STORM DRAIN CURB INLET

STORM DRAIN AREA INLET

T TRANSFORMER

AIR CONDITIONER UNIT

UTILITY POLE

GUY WIRE

OVERHEAD ELECTRIC

GAS LINE

G GAS METER

EM ELECTRIC MANHOLE

E ELECTRIC BOX

EXISTING CONTOUR LINE512

PROPOSED CONTOUR LINE512

DEMOLITION AREA

HENDRICKSON

HIGH SCHOOL

MAIN BLDG

N 62°24'53" W

1,265.06'

N 62°24'53" W

261.51'

S 27°37'07" W 122.98'

S 27°37'07" W 599.33'

HENDRICKSON

HIGH SCHOOL

MAIN BLDG

N 62°24'53" W

1,265.06'

N 62°24'53" W

261.51'

S 27°37'07" W 122.98'

S 27°37'07" W 599.33'

N

NOTES:

1. CONTRACTOR TO FIELD VERIFY ALL UTILITIES PRIOR TO THE

COMMENCEMENT OF CONSTRUCTION.

LEGEND

BOUNDARY / RIGHT OF WAY

EASEMENT / SETBACK

CURB / EDGE OF PAVEMENT

ACCESSIBLE ROUTE (ADA)

FIRE LANE STRIPING

RETAINING / SCREENING WALL

BUILDING PAD AREA

PAVEMENT / ASPHALT

PAVEMENT / CONCRETE

STORM DRAIN LINE

WATER LINE

WASTEWATER LINE

WW

D

AC

WASTEWATER MANHOLE

WATER METER

WATER VALVE

FIRE HYDRANT

CO WASTEWATER CLEANOUT

BFP BACKFLOW PREVENTER

STORM DRAIN MANHOLE

STORM DRAIN CURB INLET

STORM DRAIN AREA INLET

T

D

TRANSFORMER

AIR CONDITIONER UNIT

GUY WIRE

DUMPSTER

SIGN

BICYCLE RACK

PARKING BUMPER

ACCESSIBLE PARKING (ADA)

CROSSWALK

UTILITY POLE

TX-130 SERVICE RD

CO

PPER M

IN

E DR

COLORADO SAND DR

HENDRICKSON

HIGH SCHOOL

MAIN BLDG

N 62°24'53" W

1,265.06'

N 62°24'53" W

261.51'

S 27°37'07" W 122.98'

S 27°37'07" W 599.33'

TX-130 SERVICE RD

CO

PPER M

IN

E DR

COLORADO SAND DR

HENDRICKSON

HIGH SCHOOL

MAIN BLDG

N 62°24'53" W

1,265.06'

N 62°24'53" W

261.51'

S 27°37'07" W 122.98'

S 27°37'07" W 599.33'

N

NOTES:

1. CONTRACTOR TO FIELD VERIFY ALL UTILITIES PRIOR TO THE

COMMENCEMENT OF CONSTRUCTION.

LEGEND

BOUNDARY / RIGHT OF WAY

EASEMENT / SETBACK

CURB / EDGE OF PAVEMENT

EXISTING BUILDING

STORM DRAIN LINE

WATER LINE

WASTEWATER LINE

WW

D

AC

WASTEWATER MANHOLE

WATER METER

WATER VALVE

FIRE HYDRANT

CO WASTEWATER CLEANOUT

BFP BACKFLOW PREVENTER

STORM DRAIN MANHOLE

STORM DRAIN CURB INLET

STORM DRAIN AREA INLET

T TRANSFORMER

AIR CONDITIONER UNIT

UTILITY POLE

GUY WIRE

SIGN

TREE W/ TAG

TAG#

TREE - REMOVE

TAG#

OVERHEAD ELECTRIC

GAS LINE

G GAS METER

EM ELECTRIC MANHOLE

E ELECTRIC BOX

SURVEY ROD/NAIL

BENCHMARK

EXISTING CONTOUR LINE512

STABILIZED

CONSTRUCTION

ENTRANCE

STAGING & SPOILS AREA

SEDIMENT REMOVAL MAT FOR

CONSTRUCTION ENTRANCE

NOTES:

1. LIMITS OF CONSTRUCTION: 9.04 ACRES

2. SEE TREE PRESERVATION PLAN SHEET FOR TREE SURVEY.

3. CONTRACTOR MUST PICK UP AND DISPOSE OF ALL SEDIMENT

CONTROLS, INCLUDING SILT FENCE, ONCE PERMANENT EROSION

CONTROLS MEASURES ARE ESTABLISHED.

PPER M

IN

E DR

COLORADO SAND DR

HENDRICKSON

HIGH SCHOOL

MAIN BLDG

N 62°24'53" W

1,265.06'

N 62°24'53" W

261.51'

S 27°37'07" W 122.98'

S 27°37'07" W 599.33'

LEGEND

PPER M

IN

E DR

COLORADO SAND DR

HENDRICKSON

HIGH SCHOOL

MAIN BLDG

N 62°24'53" W

1,265.06'

N 62°24'53" W

261.51'

S 27°37'07" W 122.98'

S 27°37'07" W 599.33'

TX-130 SERVICE RD

CO

PPER M

IN

E DR

COLORADO SAND DR

HENDRICKSON

HIGH SCHOOL

MAIN BLDG

N 62°24'53" W

1,265.06'

N 62°24'53" W

261.51'

S 27°37'07" W 122.98'

S 27°37'07" W 599.33'

LEGEND

62°24'53" W

1,265.06'

S 27°37'07" W 122.98'

S 27°37'07" W 599.33'

N 62°24'53" W

1,265.06'

S 27°37'07" W 122.98'

S 27°37'07" W 599.33'

N

NOTES:

1. CONTRACTOR TO FIELD VERIFY ALL UTILITIES PRIOR TO THE

COMMENCEMENT OF CONSTRUCTION.

LEGEND

BOUNDARY / RIGHT OF WAY

EASEMENT / SETBACK

CURB / EDGE OF PAVEMENT

RETAINING / SCREENING WALL

PROPOSED BUILDING PAD AREA

STORM DRAIN LINE

WATER LINE

WASTEWATER LINE

WW

AC

WASTEWATER MANHOLE

WATER METER

WATER VALVE

FIRE HYDRANT

CO WASTEWATER CLEANOUT

BFP BACKFLOW PREVENTER

T TRANSFORMER

AIR CONDITIONER UNIT

GUY WIRE

OVERHEAD ELECTRIC

GAS LINE

EXISTING CONTOUR LINE

PROPOSED CONTOUR LINE

EXISTING GRADE

DRAINAGE SWALE FLOW LINE

EG=XXX.00

TOP OF CURB ELEVATIONTC

GUTTER ELEVATIONG

FLOW LINE ELEVATIONFL

HIGH POINT ELEVATIONHP

LOW POINT ELEVATIONLP

MATCH EXISTING ELEVATIONME

PAD ELEVATIONPE

FINISHED FLOOR ELEVATIONFFE

TOP OF WALL ELEVATIONTW

FINISHED GRADE AT WALLGW

PROPOSED FINISHED GRADEXXX.00

D STORM DRAIN MANHOLE

STORM DRAIN CURB INLET

STORM DRAIN GRATE INLET

TOP OF GRATE INLETRIM

UTILITY POLE

ZERO CURBZC

SAW TOOTH CURBST

File details come from the government source that posted it. Updated .