13 578-15-008 Drawings.pdf
PDF 12 MB Posted
- Solicitation number
- 36C25224B0010
About this file
This document appears to be a set of drawings related to the federal contract opportunity for Project 578-15-008 (CON) Update Wayfinding-Parking Signage Hines at the Edward Hines Jr. VA Hospital in Hines, Illinois.
The contract opportunity is a solicitation issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12 with the solicitation number 36C25224B0010. The project involves updating the wayfinding and parking signage at the Edward Hines Jr. VA Hospital. The drawings provided likely detail the requirements for the new signage and wayfinding system. No additional details about response dates, pricing terms, set-asides, or incumbent contractors are provided in this file.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT OFFICER REPRESENTATIVE DATE
CHIEF OF ENGINEERING DATE
INTERIOR DESIGNER DATE
DEPARTMENT HEAD DATE
CONTRACT SPECIALIST DATE LEAD USER SIGNATURE DATE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
NOT F
OR
CONSTRUCTIO
N
B
IM
/1
.6
.0
U p d a te
W a y fi n d in g S ig n a g e
A E
.6
.0
A v
.r v t
/7
/2
:2
:3
P M
GI000
COVER SHEET
GUIDON DESIGN
1221 N. PENNSYLVANIA ST., STE. 200
INDIANAPOLIS, IN 46202
317.800.6388
UPDATE WAYFINDING - PARKING
SIGNAGE ON HINES CAMPUS
EDWARD HINES JR. VA HOSPITAL
19.6001.08
VARIES
03-08-24 TS LC
19.6001.08
UPDATE WAYFINDING - PARKING SIGNAGE ON HINES
CAMPUS
VA MEDICAL CENTER
EDWARD HINES JR. VA HOSPITAL
578-15-008
100% CONSTRUCTION
DOCUMENTS
SHEET INDEX
Sheet Organizati on Sheet #
Sheet Sub- Orga nizati on
SHEET
NUMBER SHEET NAME
GENERAL
GENERAL 1 1.0 GI000 COVER SHEET
GENERAL 1 GI001 ARCHITECTURAL SYMBOLS, NOTES, AND ABBREVIATIONS
GENERAL 1 GI002 PROJECT OVERVIEW AND SIGNAGE STANDARDS
GENERAL 1 GI008 SIGNAGE ELEVATIONS - EXTERIOR GUIDES & PARKING
DEMO
DEMO 2 AD001 DEMOLITION NOTES - EXTERIOR
ARCHITECTURAL
ARCHITECTURAL 3 AI0-6PARK EXTERIOR PARKING SIGNAGE DRAWING OVERALL
ARCHITECTURAL 3 AI0-7PARK EXTERIOR PARKING SIGNAGE DRAWING ENLARGED 1
ARCHITECTURAL 3 AI0-8PARK EXTERIOR PARKING SIGNAGE DRAWING ENLARGED 2
Contact: Contact:
VA HINES MEDICAL CENTER
Jake Kanuru
Project Planning COR
5000 S. Fifth Avenue Building 2 Hines, IL 60141 p: 708-202-8387 x 21149 e: Jake.Kanuru@va.gov
OWNER
GUIDON DESIGN INC.
Luke Leising
Project Manager
1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202 p: 317.800.6388 e: luke@guidondesign.com
ARCHITECT
AREA MAP
VICINITY MAP
CAMPUS MAP
PROJECT
LOCATION
PROJECT
LOCATION
PROJECT
LOCATION
Revisions: Date:
A/C AIR CONDITION
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABC AGGREGATE BASE COURSE
AC ASBESTOS CEMENT OR ASPHALTIC CONCRETE
ACS DR ACCESS DOOR
ACS FLR ACCESS FLOOR
ACS PNL ACCESS PANEL
ACST ACOUSTIC
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADC AUTOMATIC DOOR CLOSER
ADDL ADDITIONAL
ADDN ADDITION
ADH ADHESIVE
ADJ ADJACENT, ADJOINING, OR ADJUSTABLE
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHJ AUTHORITY HAVING JURISDICTION
AHR ANCHOR
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM
AMP AMPERE
AMT AMOUNT
ANOD ANODIZE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
ANT ANTENNA
APPD APPROVED
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASB ASBESTOS
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTION
ASKLR AUTOMATIC SPRINKLER
ASPH ASPHALT
ASSN ASSOCIATION
ATCH ATTACHMENT
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVG AVERAGE
AW ACID WASTE
AWI ARCHITECTURAL WOODWORKING INSTITUTE
AWS AMERICAN WELDING SOCIETY
AWT ACOUSTICAL WALL TREATMENT
B PL BASE PLATE
BALC BALCONY
BAT BATTEN
BB BULLETIN BOARD
BD BOARD
BEV BEVEL
BI FLD DR BIFOLDING DOORS
BITUM BITUMINOUS
BKG BACKING
BLD BUILD
BLDG BUILDING
BLKG BLOCKING
BLKT BLANKET
BM BEAM OR BENCHMARK
BOT BOTTOM
BRCG BRACING
BRDG BRIDGING
BRG BEARING
BRKT BRACKET
BRZ BRONZE
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C CELSIUS CHANNEL OR CHANNEL CELSIUS
C CONC CAST CONCRETE
C TO C CENTER TO CENTER
CAB CABINET
CB CORNER BEAD
CBB CEMENTITIOUS (BACKER) BOARD
CC CUBIC CENTIMETER
CCTV CLOSED CIRCUIT TELEVISION
CCW COUNTERCLOCKWISE
CEM CEMENT
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CGSFU CERAMIC GLAZED STRUCTURAL FACING UNITS
CH BD CHALKBOARD
CHEM CHEMICAL
CHFR CHAMFER
CI CAST IRON
CIP CAST-IN-PLACE
CIR CIRCLE
CIRC CIRCULAR
CJ CONSTRUCTION JOINT OR CONTROL JOINT
CL CENTER LINE
CLDG CLADDING
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNR CORNER
CNTR COUNTER
CO CARBON MONOXIDE, CLEANOUT
CO₂ CARBON DIOXIDE
COL COLUMN
COM COMMON
COMB COMBINATION, COMBINED
COMM COMMUNICATION
COMP COMPONENT
CONC CONCRETE
COND CONDENSER OR CONDITION
CONF CONFERENCE
CONN CONNECT
CONSTR CONSTRUCTION
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CORR CORRIDOR
CPM CRITICAL PATH METHOD
CPRS COMPRESSIBLE
CPT CARPET
CRS COLD ROLLED STEEL
CS CAST CONCRETE STONE
CSB CONCRETE SPLASH BLOCK
CSG CASING
CSK COUNTER SUNK
CSMT CASEMENT
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTG COATING
CTR CENTER
CTRL CONTROL
CTV CABLE TELEVISION
CU COPPER C
CU FT CUBIC FEET
CU IN CUBIC INCH
CU YD CUBIC YARD
CURT CURTAIN
CYL CYLINDER
CYL L CYLINDER LOCK
N NORTH
NA NOT APPLICABLE
NAT NATURAL
NATL NATIONAL
NC NOISE CRITERIA
NCOMBL NONCOMBUSTIBLE
NEG NEGATIVE
NEUT NEUTRAL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NR NOISE REDUCTION
NRC NOISE REDUCTION COEFFICIENT
NRP NONREMOVABLE
NS NARROW STILE
NUM NUMERAL
O/O OUT TO OUT
O OXYGEN
OA OUTSIDE AIR OR OVERALL
OC ON CENTER
OCC OCCUPY
OCT OCTAGON
OD OUTSIDE DIAMETER OR OUTSIDE DIMENSION
OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED
OFD OVERFLOW DRAIN
OFF OFFICE
OF/OI OWNER FURNISHED/OWNER INSTALLED
OH OVERHANG
OH DR OVERHEAD (COILING) DOOR
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
OPT OPTIONAL
OR OPERATING ROOM OR OUTSIDE RADIUS
ORD ORDNANCE OR OVERFLOW ROOF DRAIN
ORG ORGANIC
ORIG ORIGINAL
ORN ORNAMENTAL
OUT OUTLET
OZ OUNCE
PAR PARALLEL OR PARAPET
PART PARTIAL
PAT PATTERN
PB PUSHBUTTON
PBD PARTICLEBOARD
PC PIECE, POLYCARBONATE OR PORTLAND CEMENT
PCC PRECAST CONCRETE
PCCP CONCRETE PAVEMENT
PCD PAPER CUP DISPENSER
PCF POUNDS PER CUBIC FOOT
PCP PORTLAND CEMENT PLASTER
PED PEDESTAL
PEN PENETRATE
PEND PENDANT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PGBD PEGBOARD
PHS PHILLIPS HEAD SCREW
PKG PACKAGE
PL PLATE, PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTER OR PLASTIC
PLBG PLUMBING
PLYWD PLYWOOD
PMTL PAINTED METAL
PNEU PNEUMATIC
PNL PANEL
POLY POLYETHYLENE (PLASTIC)
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATE
PREFIN PREFINISH
PRELIM PRELIMINARY
PREP PREPARATION
PRESS PRESSURE
PREV PREVIOUS
PRKG PARKING
PRMLD PREMOLDED
PROJ PROJECT
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT, PNEUMATIC TUBE, OR PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE (PLASTIC)
PVG PAVING
PWR POWER
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QRY QUARRY
QT QUARRY TILE
QTB QUARRY TILE BASE
QTF QUARRY TILE FLOOR
QTR QUARTER
QTY QUANTITY
QUAD QUADRANT
QUAL QUALITY
R RADIUS OR RISER
RA RETURN AIR
RAD RADIATOR
RB RESILIENT BASE OR RUBBER BASE
RB HK ROBE HOOK
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RCP REFLECTED CEILING PLAN
RCVR RECEIVER
RD ROAD OR ROOF DRAIN
REC RECESSED
RECD RECEIVED
RECPT RECEPTACLE
RECT RECTANGLE
REF REFERENCE OR REFRIGERATOR
REFR REFRACTORY REFRIGERATION OR REFRIGERATION
REFRACTORY
REG REGISTER
REINF REINFORCE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
RET RETURN
REV REVISION
RF RADIO FREQUENCY
RFG ROOFING
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RH RIGHT HAND
RHMS ROUND HEAD MACHINE SCREW
RHR RIGHT HAND REVERSE
RHWS ROUND HEAD WOOD SCREW
RL ROOF LEADER
RLG RAILING
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RPM REVOLUTIONS PER MINUTE
RS ROUGH SAWN
RT RIGHT
RV ROOF VENT
RVS REVERSE
RWD REDWOOD
RWL RAIN WATER LEADER
W/ WITH
W/O WITHOUT
WARR WARRANTY
WBL WOOD BLOCKING
WC WALL COVERING OR WATER CLOSET
WC WL HNG WATER CLOSET, WALL HUNG
WCHR WATER CHILLER
WCL WL MTD WATER COOLER, WALL HUNG
WD WOOD
WDW WINDOW
WF WIDE FLANGE
WFAB WALL FABRIC
WFR WOOD FRAME
WFS WOOD FURRING STRIPS
WH WATER HEATER
WHSE WAREHOUSE
WLD WELDED
WM WIRE MESH
WP WATERPROOFING
WPD WATER PRESSURE DROP
WPM WATERPROOF MEMBRANE
WR WEATHER RESISTANT
WS WEATHERSTRIP
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
X BRACE CROSS BRACE
XPS EXTRUDED POLYSTYRENE BOARD (INSULATION)
YD YARD
YR YEAR
D DEPTH OR PENNY (NAIL)
D LABEL CLASS D DOOR
DAT DATUM
DB DECIBEL
DBL DOUBLE
DBL GLZ DOUBLE GLAZE
DC DIRECT CURRENT
DEG DEGREE
DEL DELETE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL DIAGRAM OR DIAGRAM DIAGONAL
DIFF DIFFERENCE OR DIFFUSER
DIM DIMENSION
DIR DIRECTION
DISP DISPENSER
DIST DISTANCE
DIV DIVIDE OR DIVISION
DL DEAD LOAD
DOC DOCUMENT
DOZ DOZEN
DN DOWN
DR DOOR, DRAIN, DRESSING ROOM, OR DRIVE
DS DOWNSPOUT
DSGN DESIGN
DW DISHWASHER
DWG DRAWING
DWTR DUMBWAITER
E EAST
EA EACH
EFF EFFICIENCY
EFS EXTERIOR FINISH SYSTEM
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRIC
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER
ENVIR ENVIRONMENT
EPA ENVIRONMENTAL PROTECTION AGENCY
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EPO EMERGENCY POWER OFF
EPS EXPANDED POLYSTYRENE BOARD (INSULATION)
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ERD EXISTING ROOF DRAIN
ESC ESCAPE OR ESCUTCHEON
ESCAL ESCALATOR
EST ESTIMATE
ETC AND SO FORTH OR ET CETERA
ETS EXPOSE TO STRUCTURE
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION OR EXPOSED
EXT EXTERIOR, EXTERNAL, OR EXTINGUISHER
F FAHRENHEIT OR FEMALE
FA FIRE ALARM
FAB FABRIC
FAC FACTOR
FACIL FACILITY
FAS FASCIA
FCO FLOOR CLEANOUT
FCTY FACTORY
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FH FLAT HEAD OR FLAT HEAD SCREWS
FHC FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHP FULL HEIGHT PARTITION
FHWS FLAT HEAD WOOD SCREW
FIG FIGURE
FIL FILLET
FIN FINISH
FIP FILLER PANEL
FIXT FIXTURE
FL FLOORLINE
FLASH FLASHING
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLR FLOOR
FLUOR FLUORESCENT
FM FACTORY MUTUAL
FM-G FACTORY MUTUAL GLOBAL
FO FINISHED OPENING
FOC FACE OF CONCRETE OR FACE OF CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF SLAB OR FACE OF STUD
FOUNT FOUNTAIN
FOW FACE OF WALL
FP FIRE PROTECTION OR FIREPROOF
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FIRE RATING, FIRE RESISTANT, OR FRAME
FR SNK FLUSHING RIM SINK
FREQ FREQUENCY
FRMG FRAMING
FRP FIBER REINFORCED POLYESTER OR FIBERGLASS
REINFORCED PLASTIC
FRZ FREEZER
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET OR FOOT
FTG FOOTING
FURG FURRING
FURN FURNISH OR FURNITURE
FUT FUTURE
FWC FABRIC WALLCOVERING
GA GAGE OR GYPSUM ASSOCIATION
GAL GALLON
GALV GALVANIC OR GALVANIZED
GALV STL GALVANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR
GD GUARD
GDR GUARD RAIL
GEN GENERAL OR GENERATOR
GFRC GLASS-FIBER-REINFORCED CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GFRP GLASS-FIBER-REINFORCED PLASTIC
GI GALVANIZED IRON
GL GLASS
GLU LAM GLUED LAMINATED WOOD
GR FL GROUND FLOOR
GRAN GRANITE
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GSM GALVANIZED SHEET METAL
GSU GLAZED STRUCTURAL UNIT
GT GROUT
GUAR GUARANTEE
GUT GUTTER
GYP GYPSUM
H HIGH
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HAZ MAT HAZARDOUS MATERIALS
HB HOSE BIBB
HC HOLLOW CORE
HCWD HOLLOW CORE WOOD DOOR
HDBD HARDBOARD
HDNR HARDENER
HDO HIGH DENSITY OVERLAY
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HEX HEXAGON
HF HIGH FREQUENCY
HGR HANGER
HM HECTOMETER OR HOLLOW METAL
HMD HOLLOW METAL DOOR
HMDF HOLLOW METAL DOOR AND FRAME
HMF HOLLOW METAL FRAME
HNDRL HANDRAIL
HO HOLD OPEN
HORIZ HORIZONTAL
HOSP HOSPITAL
HP HIGH PRESSURE OR HORSEPOWER
HS HEAT-STRENGTHENED (GLASS) OR HIGH STRENGTH
HSKPG HOUSEKEEPING
HST HOIST
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
HVY HEAVY
HW HOT WATER
HYD HYDRANT
HYDR HYDRAULIC
I INTERSTATE (HIGHWAY) OR MOMENT OF INERTIA
IAQ INDOOR AIR QUALITY
IBC INTERNATIONAL BUILDING CODE
ID IDENTIFICATION, INSIDE DIAMETER
ID NO IDENTIFICATION NUMBER
ILLUM ILLUMINATION
INCL INCLUDED
IND INDEPENDENT OR INDUSTRIAL
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INTERCOM INTERCOMMUNICATION
INTL INTERNATIONAL
IRMA INVERTED ROOF MEMBRANE ASSEMBLY
IWH INSTANTANEOUS WATER HEATER
JAN JANITOR
J-BOX JUNCTION BOX
JT JOINT
KD KILN DRIED OR KNOCKED DOWN
KIT KITCHEN
KO KNOCKOUT
KPL KICKPLATE
L ANGLE
LAB LABORATORY
LAD LADDER
LAM LAMINATE
LAM GL LAMINATED GLASS
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LBS POUND
LD BRG LOAD-BEARING
LDR LEADER
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LH LEFT HAND
LHR LEFT HAND REVERSE OR LEFT HAND REVERSE
LATENT HEAT RATIO
LIB LIBRARY
LIN LINEAR
LINO LINOLEUM
LIQ LIQUID
LKR LOCKER
LKR RM LOCKER ROOM
LKWASH LOCKWASHER
LL LEAD LINED
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMST LIMESTONE
LNDSCP LANDSCAPE
LR LIVING ROOM
LRG LARGE
LRV LOUVERED ROOF VENT
LS LUMP SUM
LT LIGHT
LT GA LIGHT GAGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
LVD LOUVERED
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LWIC LIGHTWEIGHT INSULATING CONCRETE
LYR LAYER
MACH MACHINE
MACH RM MACHINE ROOM
MAINT MAINTENANCE
MAN MANUAL
MATL MATERIAL
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MB MACHINE BOLT
MCB METAL CORNER BEAD
MD DECK
ME MECHANICAL ENGINEER
MEAS MEASURE
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MED MEDICAL MEDIUM OR MEDIUM MEDICAL
MEK METHYL ETHYL KETONE
MEL MELAMINE
MEMB MEMBRANE
MEMO MEMORANDUM
MEZZ MEZZANINE
MF MILL FINISH
MFD MANUFACTURED
MFG MANUFACTURING
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATION
MGT MANAGEMENT
MH MANHOLE
MIC MICROPHONE
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM MINUTE OR MINUTE MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MIT MITER
MKR MARKER
ML METAL LATH
MLDG MOLDING (MOULDING)
MLWK MILLWORK
mm MILLIMETER
MO MASONRY OPENING OR MOTOR OPERATED
MOD MODEL, MODIFY OR MODULE
MOD BIT MODIFIED BITUMEN
MON MONITOR
MOPR MOP RACK
MR MOISTURE RESISTANT
MS MACHINE SCREW OR MOP SINK
MTD MOUNTED
MTG MOUNTING
MTL METAL
MULL MULLION
MW MICROWAVE
MWP MEMBRANE WATERPROOFING
SA SUPPLY AIR
SALV SALVAGE
SAMP SAMPLE
SAN SANITARY
SAT SUSPENDED ACOUSTICAL TILE
SATC SUSPENDED ACOUSTICAL TILE CEILING
SB SPLASH BLOCK
SBS STYRENE BUTADIEN STYRENE
SBSTR SUBSTRATE
SC SHADING COEFFICIENT OR SOLID CORE
SCH SCHOOL
SCHED SCHEDULE
SCHEM SCHEMATIC
SCP SCUPPER
SCRN SCREEN
SCT STRUCTURAL CLAY TILE
SCWD SOLID CORE WOOD DOOR
SD SHOP DRAWINGS, SMOKE DETECTOR OR SOAP
DISPENSER
SDG SIDING
SECT SECTION
SEG SEGMENT
SEL SELECT
SEP SEPARATE
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGD SLIDING GLASS DOOR
SGL SINGLE
SHR SHOWER
SHR HD SHOWER HEAD
SHRD SHOWER DRAIN
SHT SHEET
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SK SKETCH
SKLT SKYLIGHT
SLD WDW HORIZONTAL SLIDING WINDOW
SLDG SLIDING
SLNT SEALANT
SM SHEET METAL
SMK SMOKE
SND SANITARY NAPKIN DISPENSER
SND INS SOUND INSULATION
S SOUTH
SNDU SANITARY NAPKIN DISPOSAL UNIT
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SPLY SUPPLY
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SANITARY SEWER OR SERVICE SINK
SST STAINLESS STEEL
ST STAIRS OR STREET
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIF STIFFENER
STL STEEL
STL LNTL STEEL LINTEL
STL RF DK STEEL ROOF DECK
STL TB STEEL TUBE
STNLS STAINLESS
STOR STORAGE
STR STRINGERS
STRUCT STRUCTURAL
SUB SUBSTITUTE
SURF SURFACE
SUSP SUSPEND
SV SHEET VINYL
SW SWITCH
SWDR SWING DOOR
SYM SYMBOL
SYNTH SYNTHETIC
SYS SYSTEM
T TREAD
TA TOILET ACCESSORY
T&G TONGUE AND GROOVE
T&M TIME AND MATERIALS
TB THROUGH BOLT OR TOWEL BAR
TCA TILE COUNCIL OF AMERICA
TCP TELEPHONE CONTROL PANEL OR TEMPERATURE
CONTROL PANEL OR TRAFFIC CONTROL PLAN
TD TOWEL DISPENSER
TECH TECHNICAL
TEL TELEPHONE
TEMP TEMPERATURE OR TEMPORARY
TER TERRAZZO
THD THREAD
THERM THERMAL
THK THICKNESS
THRES THRESHOLD
THRU THROUGH
THRUOUT THROUGHOUT
TK BD TACKBOARD
TMPD TEMPERED
TN TRUE NORTH
TO TOP OF ___
TO FDN TOP OF FOUNDATION
TOB TOP OF BEAM
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPH TOILET PAPER HOLDER
TR TOWEL RACK
TRANS TRANSOM
TRANS WD FIN TRANSPARENT WOOD FINISH
TRTD TREATED
TS TENSILE STRENGTH OR TUBE STEEL
TSTAT THERMOSTAT
TV TELEVISION
TYP TYPICAL
U HEAT TRANSFER COEFFICIENT
UC UNDERCUT
UCD UNDERCUT DOOR
UGND UNDERGROUND
UL UNDERWRITERS LABORATORIES
ULT ULTIMATE
UNFIN UNFINISH
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
UTIL UTILITY
UV ULTRAVIOLET
V VOLT
VAC VACUUM
VAR VARIES
VCT VINYL COMPOSITION TILE OR VITRIFIED CLAY TILE
VEH VEHICLE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VFAT VINYL FACED ACOUSTICAL TILE
VIC VICINITY
VID VIDEO
VIF VERIFY IN FIELD
VNR VENEER
VOC VOLATILE ORGANIC COMPOUND
VOL VOLUME
VOLT VOLTAGE
VP VENEER PLASTER
VR VAPOR RETARDER
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
ARCHITECTURAL ABBREVIATIONS
A. THE VA HINES MEDICAL CENTER CURRENTLY HAS INCONSISTENT SIGNAGE
TYPES FROM BUILDING TO BUILDING. SIGNAGE IS OUTDATED AND OFTEN NO
LONGER COMPLIANT. THE NEW BASIS OF DESIGN INCORPORATES A
COMPONENT SIGN SYTEM BROKEN DOWN BY BUILDING, PARKING, AND
EXTERIOR SITE SIGNAGE. THESE LOCATIONS ARE DENOTED ON THE COVER
SHEET AND DETAILED IN THE FOLLOWING DRAWING SET.
B. DEMOLITION SCOPE: PROJECT SCOPE INCLUDES THE REMOVAL AND
DISPOSAL OF ALL EXISTING PARKING LOT IDENTIFIER SIGNS ON THE VA
HINES MEDICAL CENTER CAMPUS UNLESS INDICATED TO REMAIN.
CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL AND DISPOSAL
OF RELATED ITEMS WHICH ARE REMOVED TO ACCOMMODATE THE SIGNAGE
REMOVAL, INCLUDING MOUNTING HARDWARE, CONCRETE PEDESTALS,
POSTS, ELECTRICAL CONDUIT, ETC.
THE FOLLOWING SIGNS/TYPES ARE TO BE LEFT AS EXISTING TO REMAIN:
a. TRAFFIC CONTROL
b. STREET SIGNS
c. ADA PARKING SIGNS d.
C. NEW SCOPE: PROJECT SCOPE INCLUDES THE REPLACEMENT OF THE
PARKING SIGNAGE TO ESTABLISH A CONSISTANT STANDARD ACROSS ALL
HINES CAMPUS. THE ADDITION OF NEW WAYFINDING SIGNAGE WILL ASSIST
PATIENTS, VISITORS, AND STAFF IN LOCATING THEIR DESTINATION. THE
FOLLOWING SIGN TYPES WILL BE REPLACED OR ADDED.
EXTERIOR PARKING
D. FINISHES: WHERE DEMOLITION AND NEW WORK SCOPE DAMAGES EXISTING
FINISHES OR REVEALS A DAMAGED, INCONSISTENT, OR OTHERWISE
UNACCEPTABLE LEVEL OF FINISH, CONTRACTOR IS REQUIRED TO PROVIDE
NEW FINISHES. EXISTING FINISHES SHALL BE MATCHED AS CLOSELY AS
POSSIBLE. ANY DEVIATIONS MUST BE APPROVED BY THE VA.
PROJECT SCOPE OVERVIEW
A. DUE TO THE NATURE OF THIS PROJECT, WHICH SPANS ACROSS A NUMBER
OF AREAS IN VARYING LOCATIONS, THE CONTRACTOR WILL NOT BE ABLE TO
COMPLETE THE ENTIRE PROJECT IN A SINGLE PHASE. COORDINATE ALL
PROJECT SCHEDULES WITH VA COR AND PROJECT PLANNING AT EACH
LOCATION.
B. ALL FACILITIES WILL HAVE ONGOING OPERATIONS THORUGHOUT THE
COMPLETION OF THIS PROJECT. ALL REMOVED SIGNAGE SHALL BE
REPLACED WITH THE NEW SIGNAGE WITHIN THE SAME WORK SHIFT. IF A
SIGN CANNOT BE REPLACED WITHIN A SINGLE SHIFT, TEMPORARY SIGNAGE
IS REQUIRED TO BE PROVIDED.
C. ALL WORK WITHIN THE MEDICAL FACILITIES SHALL TAKE PLACE BETWEEN
THE HOURS OF 5:00PM AND 5:00AM, ON WEEKENDS, OR AS SCHEDULED WITH
THE COR. WORK REQUIRING VIBRATION OR LOUD NOISE SHALL BE KEPT TO
A MINIMUM.
D. EXIT/ACCESS FOR OPERATIONAL AREAS SHALL BE MAINTAINED AT ALL
TIMES.
E. ALL DEMOLITION MATERIAL SHALL BE REMOVED FROM THE PROJECT
BOUNDARY THROUGH THE FACILITY TO DUMPSTER ALONG APPROVED
ROUTE IN ENCLOSED DUMPSTER CART, DESIGNED FOR SUCH PURPOSE,
WITH A LID.
F. ALL MATERIAL, DEBRIS, AND HAZARDOUS MATERIALS SHALL BE PROPERLY
STORED IN DESIGNATED AREAS AND APPROVED CONTAINERS. FLAMMABLE
MATERIALS SHALL NOT BE STORED IN THE FACILITY.
G. CONTRACTOR IS REQUIRED TO REPAIR EXISTING/NEW FINISHES WHICH ARE
DAMAGED BY TEMPORARY CONSTRUCTION, WHETHER SPECIFICALLY NOTED
OR NOT.
K. ALL EXISTING SIGNAGE IS TO BE REMOVED AND REPLACED UNLESS NOTED
OTHERWISE. ANY SIGNS TO BE INSTALLED IN A NEW LOCATION ARE
IDENTIFIED WITH A NOTE INDICATING NEW. ANY SIGNS TO BE REMOVED
WITHOUT REINSTALLATION ARE IDENTIFIED WITH A NOTE INDICATING DEMO.
CONSTRUCTION AND PHASING NOTES
A. CONTRACTOR SHALL BE REQUIRED TO PATCH ANY AND ALL DAMAGE TO
EXISTING CONSTRUCTION WHICH IS CAUSED BY THE REMOVAL OF EXISTING
SIGNAGE OR BY THE INSTALLATION OF NEW SIGNAGE, AND WHERE NEW
SIGNAGE DOES NOT HIDE THE DAMAGE COMPLETELY. MATCH EXISTING
FINISH.
B. CONTRACTOR SHALL VERIFY ANY DESCRIPENCIES ON EXISTING OR NEW
SIGNAGE LOCATIONS WITH VA PRIOR TO FABRICATION AND INSTALLATION.
C. AREAS IN THE MEDICAL FACILITIES MAY BE SECURED, RESTRICTED, OR
REQUIRE SPECIAL PRECAUTIONS TO PERFORM WORK. COORDINATE ALL
WORK WITH COR. NO SCHEDULE EXTENSIONS OR COST MODIFICATIONS
WILL BE CONSIDERED FOR WORK NOT SCHEDULED APPROPRIATELY.
D. THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING
REVIT® SOFTWARE IN A MICROSOFT WINDOWS ENVIRONMENT. A BUILDING
INFORMATION MODEL (BIM) HAS BEEN DEVELOPED FOR DESIGN
COMMUNICATION. THE MODEL DOES NOT CONTAIN COMPLETE INFORMATION
FOR USE IN COST ESTIMATING, SYSTEMS PERFORMANCE, COORDINATION,
SCHEDULING, FABRICATION, OR FACILITIES MANAGEMENT.
E. THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING THE
CONSTRUCTION SPECIFICATIONS INSTITUTE'S UNIFORM DRAWING SYSTEM
AND THE NATIONAL CAD STANDARD AS GUIDES.
F. DISCREPANCIES IN THE CONTRACT DOCUMENTS SHALL BE IMMEDIATELY
BROUGHT TO THE ATTENTION OF THE ARCHITECT AND OWNER’S
REPRESENTATIVE / CONTRACTING OFFICER REPRESENTIVE (COR).
CONTRACTOR SHALL PROVIDE THE HIGHER GRADE OF QUALITY AND/OR
GREATER QUANTITY OF WORK WHEN BIDDING IF A CLARIFICATION CAN NOT
BE OBTAINED BY THE BID DUE DATE.
G. CONTRACTOR IS RESPONSIBLE FOR COORDINATING SCOPE OF WORK WITH
OWNER’S REPRESENTATIVE/COR AND VARIOUS FACILITY PERSONNEL
INVOLVED WITH UTILITY SHUT DOWN, INFECTION CONTROLS,
OCCUPANT/EMPLOYEE SAFETY, ACCESS CONTROL, ETC. ALL OUTAGES
REQUIRE 15 CALENDAR DAYS ADVANCE NOTICE.
H. ANY INDICATION OF PROJECT LIMITS OR BOUNDARY OF DEMARCATION ARE
SHOWN FOR THE CONVENIENCE OF THE CONTRACTOR, THE FULL SCOPE OF
THE PROJECT LIMIT OF BOUNDARY REQUIRES COORDINATION WITH THE
DESIGN SCOPE OF WORK AND ACCESS TO EXISTING UTILITIES FOR TIE IN.
I. DRAWINGS HAVE BEEN PREPARED FROM FIELD VERIFICATION, EXISTING
FACILITY DRAWING BASE FILES, AND USING DIMENSIONS, CONFIGURATIONS
AND DETAILS OF SPECIFIC MANUFACTURERS AS A BASIS OF DESIGN.
CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ACTUAL DIMENSIONS,
THE COORDINATION OF THE DETAILS WITH THE PRODUCTS WHICH ARE
PROVIDED PER THE SCOPE OF THE SPECIFICATIONS AND THE
SURROUNDING CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS,
ROUGH-IN DIMENSIONS, CONNECTIONS, AND OVERALL INSTALLATION
REQUIREMENTS.
J. CONTRACTOR IS RESPONSIBLE FOR THE COMPLETION OF THE ENTIRE
SCOPE OF WORK OUTLINED IN THE CONTRACT DOCUMENTS. CONTRACTOR
IS RESPONSIBLE FOR THE COORDINATION OF ALL SUB-CONTRACTORS AND
THE SCOPE OF WORK THEY PROVIDE. SUB-CONTRACTORS ARE
RESPONSIBLE FOR THEIR FULL SCOPE OF WORK WITHIN THE CONTRACT
DOCUMENTS, TRADES ARE NOT SEGMENTED TO ONLY CERTAIN SHEETS AND
SPECIFICATIONS, CROSS COORDINATION IS REQUIRED.
K. CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR
UNDERSTANDING INFORMATION OUTLINED IN THE SPECIFICATIONS, KEY
NOTES, GENERAL NOTES, LEGEND, CODES, ETC., PROVIDED IN THE
CONTRACT DOCUMENTS.
L. CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR
PROVIDING AND MAINTAINING SMOKE/FIRE RATINGS OF NEW
CONSTRUCTION AND EXISTING CONSTRUCTION. THIS INCLUDES PATCHING
PENETRATIONS IN SHAFTS, WALLS, SLABS AND ROOF. ONLY U.L. APPROVED
METHODS, MATERIALS AND INSTALLATION ARE ACCEPTABLE.
M. CONTRACTOR IS RESPONSIBLE FOR VERIFYING DIMENSIONS IDENTIFIED
AND NOT IDENTIFIED IN THE CONTRACT DOCUMENTS WITH THE EXISTING
AND NEW CONSTRUCTION ELEMENTS. CONTRACTOR IS RESPONSIBLE FOR
VERIFICATION BETWEEN THE CONTRACT DOCUMENTS, INSTALLED AND
UNINSTALLED CONSTRUCTION BEFORE THE ORDERING OF MATERIALS AND
EQUIPMENT. NOTIFY ARCHITECT AND OWNER’S REPRESENTATIVE/COR OF
ANY DISCREPANCIES OR MISSING DIMENSIONS.
N. DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR
GENERAL ORIENTATION AND CONTEXT ONLY.
O. THE TERM "ALIGN" MEANS TO INSTALL DIFFERENT/SIMILAR COMPONENTS OF
CONSTRUCTION TO PROVIDE A FLUSH FINISH SURFACE.
P. ALL DIMENSIONS INDICATED ARE TO FACE OF EXISTING MEMBERS, FACE OF
NEW STRUCTURAL MEMBERS, FACE OF NEW MASONRY, FACE OF NEW
STUDS OR COLUMN GRID LINES UNLESS NOTED OTHERWISE.
Q. CONTRACTOR TO PROVIDE WORK WHERE DETAILS AND NOTES ARE
IDENTIFIED AS "TYPICAL” OR “SIMILAR” EACH INSTANCE THAT IS THE SAME IN
NATURE TO THE DETAIL, AREA, OR ITEM REFERENCED.
R. PROVIDED WORK SHALL BE FURNISHED AND INSTALLED BY THE
CONTRACTOR. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF
DELIVERY, MOUNTING, INSTALLATION, NECESSARY BLOCKING AND ROUGH-
IN.
S. INSTALLED WORK IS THE CONTRACTOR INSTALLING OWNER FURNISHED
MATERIALS AND EQUIPMENT. CONTRACTOR IS RESPONSIBLE FOR
COORDINATION OF MATERIAL DELIVERY, MOUNTING, INSTALLATION AND
ROUGH IN.
T. FURNISHED WORK IS THE CONTRACTOR FURNISHING THE MATERIALS AND
EQUIPMENT TO THE OWNER. CONTRACTOR IS RESPONSIBLE FOR
COORDINATION OF DELIVERY AND ROUGH-IN.
U. ALL PROVIDED WORK SHALL BE WITH NEW MATERIALS UNLESS
SPECIFICALLY CALLED OUT AS SALVAGED OR RELOCATED WITHIN THE
CONTRACT DOCUMENTS.
V. ALL PERSONS DIRECTLY OR INDIRECTLY ASSOCIATED WITH THE PROJECT
SHALL BE FAMILIAR WITH THE RULES AND REGULATIONS OF THE
OCCUPATIONAL SAFETY AND HEALTH ACT, AND IMPLEMENT THOSE RULES
AS THEY APPLY TO THIS PROJECT.
W. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ADJACENT
CONSTRUCTION, FINISHES, EQUIPMENT, AND TRAVEL ROUTE TO AND FROM
THE CONSTRUCTION SITE. ANY DAMAGE OR UNACCEPTABLE WEAR BY THE
CONSTRUCTION TEAM SHALL BE REPAIRED/REPLACED BY THE CONTRACTOR
AT NO COST TO THE OWNER.
X. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY SITE SURVEYS TO VERIFY
EXISTING UTILITIES FOR EXTERIOR SIGNAGE. COORDINATE FINAL INSTALL
LOCATION WITH COR AND SHOP DRAWINGS. IF A NEW INSTALLATION
LOCATION IS REQUIRED, DIRECTIONALS SHALL BE UPDATED ACCORDINGLY.
Y. CONTRACTOR SHALL BUDGET AN ADDITIONAL 5% OF EACH INTERIOR SIGN
TYPE TO CORRECT DISCREPENCIES NOT PREVIOUSLY IDENTIFIED. THESE
SIGNS SHALL BE IDENTIFIED AND LOCATED IN THE FIELD BY THE COR.
Z. CONTRACTOR MUST PRINT SET IN COLOR IN ORDER TO IDENTIFY ALL SIGN
TYPES.
AA. SIGNAGE CONTENT SHALL MATCH LEGENDS FOR EACH BUILDING. SIGN
COLOR, FONT, AND MATERIALS SHOULD MATCH ALL TYPICAL ELEVATIONS
ON GI SERIES AND ABA REQUIREMENTS. CONTRACTOR IS TO PROVIDE SHOP
DRAWINGS FOR ALL SIGNAGE.
SIGNAGE GENERAL NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
NOT F
OR
CONSTRUCTIO
N
B
IM
/1
.6
.0
U p d a te
W a y fi n d in g S ig n a g e
A E
.6
.0
A v
.r v t
/7
/2
:2
:3
P M
GI001
ARCHITECTURAL SYMBOLS,
NOTES, AND ABBREVIATIONSGUIDON DESIGN
1221 N. PENNSYLVANIA ST., STE. 200
INDIANAPOLIS, IN 46202
317.800.6388
UPDATE WAYFINDING - PARKING
SIGNAGE ON HINES CAMPUS
EDWARD HINES JR. VA HOSPITAL
19.6001.08
VARIES
03-08-24 TS LC
100% CONSTRUCTION
DOCUMENTS
STANDARDIZED NAME
STORAGE
CLEAN SUPPLY
HOUSEKEEPING
ELECTRICAL
MECHANICAL
TELECOMMUNICATION ROOM
OFFICE
DIRECTOR'S OFFICE
EXAM (# IN SEQUENCE BY
DEPARTMENT)
MEN'S RESTROOM
WOMEN'S RESTROOM
MEN'S LOCKER ROOM
WOMEN'S LOCKER ROOM
BREAK ROOM
LABORATORY
FOURTH FLOOR
SECTION
TYPICAL ROOM NAMES
EXAMPLES OF OTHER NAMES NO LONGER TO BE USED
EMD SUPPLY
SUPPLY
JAN., JANITOR
ELECT, ELECTRICAL EQUIPMENT
MECH
COMM, IT,
INDIVIDUAL NAMES
INDIVIDUAL NAMES
EXAM, EXAM ROOM 1
MEN, RESTROOM, MEN'S
WOMEN, RESTROOM, WOMEN'S
MEN, LOCKER
WOMEN, LOCKER
LOUNGE
LAB
4TH FLOOR, FLOOR 4, LEVEL 4
ZONES, AREA
NOTE: ROOMS COMMONLY FOUND THROUGHOUT FACILITIES SHALL HAVE A
CONSISTENT NAMING CONVENTION. SEE BELOW FOR STANDARDIZED ROOM NAMES.
ALL VERBIAGE INDICATED IN THE SIGNAGE SCHEDULES SHOULD FOLLOW THE NAMING
STANDARDS AND BE VERIFIED AND APPROVED BY THE PROJECT PLANNING TEAM
PRIOR TO INSTALLATION. WHITE
VA BLUE PANTONE 541
ALUMINUM
EMERGENCY RED
ACCENT COLOR SECTION A - POMEGRANATE AF-295
ACCENT COLOR SECTION B - AVALON TEAL CSP-645
ACCENT COLOR SECTION C - TUMERIC 2160-20
ACCENT COLOR SECTION D - ELDERBERRY WINE
CSP-470
ACCENT COLOR SECTION E - CUCUZZA VERDE
SW9038
ACCENT COLOR SECTION F - COPPER HARBOR
SW6634
ACCENT COLOR SECTION G - CAPE VERDE SW6482
PARKING ACCENT COLOR 1 - PATIENT ONLY
B35 ANOLE GREEN
PARKING ACCENT COLOR 2 - STAFF & PATIENT
B38 AQUA RIVA
PARKING ACCENT COLOR 3 - OTHER INCLUDING
CONTRACTOR, UNDER CONSTRUCTION, & LEASED
B30 PURPLE PRINT
SECTION ACCENT COLOR LEGEND
NOTE: ALL COLORS ARE SCHEMATIC AND SHALL BE REVIEWED WITH OWNER PRIOR
TO PRODUCTION.
STANDARDIZED SIGNAGE NUMBER
WITH BRAILLE (GRADE 2)
TYPICAL ROOM NUMBER
NOTE: ROOMS COMMONLY FOUND THROUGHOUT THE FACILITIES SHALL MATCH THE
EXISTING ROOM NUMBERS. SEE BELOW FOR STANDARDIZED ROOM NUMBERING TO BE
INDICATED ON ALL ROOM SIGNAGE WITHIN A SECTION OF A BUILDING. ALL NUMBERS
INDICATED IN THE SIGNAGE REPORT SHOULD FOLLOW THE NUMBERING STANDARD
AND BE VERIFIED AND APPROVED BY THE VA PRIOR TO INSTALLATION.
X # # # #
SECTION LETTER
MAY NOT APPLY TO ALL BUILDINGS
ROOM NUMBER
TO BE VERIFIED
TO MATCH
CURRENT
FLOOR LAYOUT
SIGNAGE DESIGN ELEMENTS
Helvetica Bold is the standard typeface for the VA Sign System. Signs identifying permanent rooms shall be ABA compliant. All non-ABA signs are to maintain an upper and lower case format regardless of format shown in the signage legends. Overhead signs shall be Helevtica Bold Condensed. Normal letter spacing is utilized when the readability ratio factor is 1:25 for a word using upper and lower case letters. Distance letter spacing shall be utilized when the copy content is intended for readability at greater viewing distances and the readability ratio factor is 1:40.
Line spacing shall be no less than 1/2 the height of the upper case letter form. Paragraph spacing shall be no less than the height of the upper case letter form.
Standard arrow illustrations are below. The arrow is always centered within a square field, and is always positioned so that it is centered in relationship to the capital letter that it precedes. The arrow size is 1 1/2 times the capital letter height.
DEMO NOTE INDICATES SIGNAGE TO BE REMOVED AND NOT REPLACED.
SUBSTRATE IS TO BE PATCHED AND REPAIRED AS NEEDED TO MATCH
EXISTING FINISH.
NEW NOTE INDICATES SIGNAGE TO BE INSTALLED IN A LOCATION WHERE
SIGNAGE DOES NOT CURRENTLY EXIST.
SIGNAGE TAGS WITHOUT A DEMO OR NEW NOTE ARE TO BE REMOVED AND
REPLACED AS NEW ACCORDING TO THE REFERENCED SIGNAGE LEGENDS.
SUBSTRATE IS TO BE PATCHED AND REPAIRED AS NEEDED TO MATCH
ADJACENT FINISHES.
SIGNAGE TAG LEGEND
DEMO
NEW
PARKING LOT
PARKING LOT LANE
NONE
CONTRACTOR SHALL PROVIDE AN ADDITIONAL 10% OF EACH SIGN TYPE TO CORRECT DISCREPANCIES NOT PREVIOUSLY IDENTIFIED. THESE SIGNS SHALL BE IDENTIFIED AND
LOCATED IN THE FIELD WITH THE COR. GOVERNING CODES AND REFERENCES
UFC 3-120-01
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD FOR DEPARTMENT OF DEFENSE FACILITIES (ABAAS)
INTERNATIONAL BUILDING CODE (IBC)
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101
UFGS 10 14 00
APPLICABILITY OF CODES TO THE PROJECT:
SIGNAGE TO BE INSTALLED ON THIS PROJECT SHALL COMPLY WITH ALL APPLICABLE CODES AND THE VA SIGNAGE GUIDE. THE REQUIREMENTS IN THIS CODE SUMMARY APPLY
ONLY TO NEW SIGNAGE.
• BUILDING DIRECTORIES, MENUS, OCCUPANT NAMES, BUILDING ADDRESSES, AND COMPANY NAMES AND LOGOS SHALL NOT BE REQUIRED TO COMPLY WITH ABAAS.
• IN PARKING LOT, SIGNS SHALL ONLY BE REQUIRED TO COMPLY WITH MEANS OF EGRESS AND PARKING SIGNAGE REQUIREMENTS.
• TEMPORARY, 7 DAYS OR LESS, SIGNS SHALL NOT BE REQUIRED TO COMPLY WITH ABA.
• INTERIOR AND EXTERIOR SIGNS IDENTIFYING PERMANENT ROOMS AND SPACES SHALL COMPLY WITH ALL ABAAS REQUIREMENTS. PICTOGRAMS THAT PROVIDE
INFORMATION ABOUT A ROOM OR SPACE, SUCH AS 'NO SMOKING', ARE NOT REQUIRED TO HAVE TEXT DESCRIPTORS.
• SIGNS THAT PROVIDE DIRECTION TO OR INFORMATION ABOUT INTERIOR SPACES AND FACILITIES OF THE SITE SHALL ONLY BE REQUIRED TO COMPLY WITH 'VISUAL
CHARACTERS' REQUIREMENTS.
1. THIS INCLUDES RULES OF CONDUCT, OCCUPANT LOAD, DIRECTION TO ROOMS OR SPACES, AND EGRESS ROUTE IDENTIFICATION.
A. SIGNS FOR MEANS OF EGRESS INCLUDE EXIT DOORS, AREAS OF REFUGE, AND DIRECTIONAL SIGNS.
2. DOORS AT EXIT PASSAGEWAYS, EXIT DISCHARGE, AND EXIT STAIRWAYS SHALL BE IDENTIFIED BY TACTILE SIGNS BUT DO NOT NEED TO HAVE BRAILLE AND
DO NOT NEED TO MEET HEIGHT AND LOCATION REQUIREMENTS FOR TACTILE SIGNS.
3. AREAS OF REFUGE SIGNS NEED ONLY TO COMPLY WITH 'VISUAL CHARACTERS' REQUIREMENTS.
4. SIGNS PROVIDING DIRECTIONS TO ACCESSIBLE MEANS OF EGRESS NEED ONLY TO COMPLY WITH 'VISUAL CHARACTERS' REQUIREMENTS.
• ALL ENTRANCES, ELEVATORS, TOILET AND BATHING ROOMS ARE ASSUMED TO COMPLY WITH ABAAS REQUIREMENTS.
PROJECT SCOPE
THE PROJECT SCOPE INCLUDES THE REMOVAL OF EXISTING SIGNAGE AND PROVISION OF NEW SIGNAGE. FOR SIGNAGE TYPES TO BE REMOVED AND TO BE PROVIDED, REFER
TO ARCHITECTURAL SIGNAGE STANDARDS 'AS' SHEETS.
CODE REVIEW
1. INTERIOR FINISH
• WALLS AND CEILINGS: INTERIOR FINISH FLAME SPREAD SHALL BE LIMITED PER CHAPTER 8 OF THE NFPA 101 TO CLASS A, B AND C MATERIALS. INTERIOR WALL AND
CEILING FINISH SHALL BE CLASS A OR CLASS B IN EXITS, CORRIDORS AND LOBBIES; AND CLASS A, CLASS B, OR CLASS C IN ALL OTHER AREAS. (LSC 38.3.3)
• · CLASS A: FLAME SPREAD 0-25; SMOKE DEVELOPED 0-450.
• · CLASS B: FLAME SPREAD 26-75; SMOKE DEVELOPED 0-450.
• · CLASS C: FLAME SPREAD 76-200; SMOKE DEVELOPED 0-450
• FLOORS: INTERIOR FLOOR FINISH SHALL BE CLASS I OR CLASS II IN CORRIDORS AND EXITS.
• FABRIC DRAPERIES, CURTAINS (EXCLUDING SHOWER CURTAINS, BUT INCLUDING CUBICLE CURTAINS), AND OTHER LOOSELY HANGING FABRICS AND FILMS SERVING AS
FURNISHINGS OR DECORATIONS IN HEALTH CARE OCCUPANCIES MUST MEET THE FLAME RESISTANCE REQUIREMENTS OF NFPA 701, STANDARD METHODS OF FIRE
TESTS FOR FLAME-RESISTANT TEXTILES AND FILMS.
• UPHOLSTERED FURNITURE AND MATTRESSES. UPHOLSTERED FURNITURE AND MATTRESSES MUST ALSO MEET SPECIFIED REQUIREMENTS, BASED ON NFPA 260, NFPA
261, NFPA 266, 16 CFR 1632, ASTME E1537, AND ASTME E1590
2.SIGNAGE
RAISED CHARACTERS
• RAISED CHARACTERS SHALL BE DUPLICATED IN BRAILLE.
• RAISED CHARACTERS SHALL BE 1/32" MIN ABOVE THEIR BACKGROUND.
• CHARACTERS SHALL BE UPPERCASE AND IN HORIZONTAL FORMAT. SEE TABLE 703.5.5 IN "ABA ACCESSIBILITY STANDARDS FOR FEDERAL FACILITIES".
• CHARACTERS SHALL BE SANS SERIF, HELVETICA FONT. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE, OR OF OTHER UNUSUAL FORMS.
• CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASELINE OF THE CHARACTER SHALL BE 5/8" MIN AND 2" MAX BASED ON THE HEIGHT OF THE UPPERCASE
LETTER 'I'.
• CHARACTER SPACING SHALL BE MEASURED BETWEEN THE 2 CLOSEST POINTS OF ADJACENT RAISED CHARACTERS WITHIN A MESSAGE, EXCLUDING WORD SPACES.
WHERE CHARACTERS HAVE RECTANGULAR CROSS SECTIONS, SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/8" MIN AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAX. WHERE CHARACTERS HAVE OTHER CROSS SECTIONS, SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/16" MIN AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAX AT TEH BASE OF THE CROSS SECTIONS, AND 1/8" MIN AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAX AT THE TOP OF THE CROSS SECTIONS. CHARACTERS SHALL BE SEPARATED FROM RAISED BORDERS AND DECORATIVE ELEMENTS 3/8" MIN.
• SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF RAISED CHARACTERS WITHIN A MESSAGE SHALL BE 135% MIN AND 170% MAX OF THE RAISED CHARACTER
HEIGHT.
• BRAILLE SHALL BE CONTRACTED (GRADE 2). COMPLY WITH ABAAS REQUIREMENTS.
VISUAL CHARACTERS (NOT RAISED OR BRAILLE)
• CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT
CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND.
• CHARACTERS MAY BE ANY COMBINATION OF LOWER OR UPPER CASE.
• CHARACTERS SHALL BE CONVENTIONAL.
• CHARACTER HEIGHT:
• CHARACTERS SHALL BE 40" MIN. FROM GROUND
PICTOGRAMS
• PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6" MIN. CHARACTERS AND BRAILLE SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD.
• PICTOGRAMS SHALL HAVE TEXT DESCRIPTORS LOCATED DIRECTLY BELOW THE PICTOGRAM FIELD.
SYMBOLS OF ACCESSIBILITY
• SYMBOLS OF ACCESSIBILITY AND THEIR BACKGROUND SHALL HAVE A NON GLARE FINISH. SYMBOLS OF ACCESSIBILITY SHALL CONTRAST WITH THEIR BACKGROUND
WITH EITHER A LIGHT SYMBOL ON A DARK BACKGROUND OR A DARK SYMBOL ON A LIGHT BACKGROUND.
LOCATION OF SIGNS WITH RAISED LETTERS AND/OR BRAILLE
• TACTILE LETTERING ON SIGNS SHALL BE LOCTED 48" MIN ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST TACTILE
CHARACTER AND 60" MAX ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST TACTILE CHARACTER.
• WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT
DOUBLE DOORS WITH 1 ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH 2 ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT SIDE OF DOUBLE DOORS, SIGNS SHALL BE LOCATED SO THAT CLEAR FLOOR SPACE OF 18" MIN BY 18" MIN, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION.
CODE ANALYSISGENERAL MOUNTING AND INSTALLATION NOTES
• THE CONTRACTOR & SIGNAGE VENDOR ARE RESPONSIBLE FOR
DETERMINING THE BEST METHOD OF INSTALLATION BASED ON THE FINAL
SIGNAGE SIZE, WEIGHT, AND DURABILITY TO MINIMIZE DAMAGE TO THE
EXISTING SUBSTRATES.
• CONTRACTOR IS RESPONSIBLE FOR ADHERING ALL SIGNAGE SO THAT IT IS
STRUCTURLY SECURE.
• FOR EXTERIOR SITE SIGNAGE CONTRACTOR IS RESPONSIBLE FOR
COMPLETING NECCESSARY SURVEYS TO SAFELY SECURE SIGNAGE INTO THE
GROUND OR MOUNTING SURFACE.
• ALL EXTERIOR SIGNS SHOULD BE LOCATED A MINIMUM OF 2'-0" FROM THE
CURB. THE EXACT LOCATION OF A SIGN WILL VARY DEPENDING ON THE TYPE
OF SIGN AND SITE CONDITIONS. SIGN PLACEMENT MUST BE CAREFULLY
CONSIDERED TO ENSURE THAT THE SIGN FITS THE LOCATION WITHOUT
MAJOR REGRADING. IT MAY BE NECESSARY TO CLEAR EXISTING SHRUBS OR
BUSHES OR RELOCATE AN OBSTRUCTION. WHEN SIGNS ARE PLACED ON
SLOPING OR INCLINED GRADES, ADJUSTMENTS MUST BE MADE TO POST
LENGTHS. EXTREME DIFFERENCES BETWEEN POST LENGTHS SHOULD BE
MINIMIZED.
• CONTRACTOR SHOULD FOLLOW THE VA SIGNAGE GUIDE FOR BOTH
EXTERIOR AND SPECIALTY SIGNS INSTALLATION AND VIEWING
REQUIREMENTS.
• POSITION SIGNS WITH A CLEAR LINE OF SIGHT FROM THE VIEWING POINT TO
THE SIGN FACE. SIGNS SHOULD BE INSTALLED TO BE PERPENDICULAR TO
THE INTENDED VIEWER.
MOUNTING TYPE LEGEND
REFER TO INDIVIDUAL SIGNAGE ELEVATIONS AND SIGNAGE REPORTS FOR
RECOMMENDED INSTALLATION DETAIL AND METHOD FOR EACH SIGN.
H. POLE MOUNT - SIGN TO BE SECURED ON EXISTING EXTERIOR LAMP POSTS
WITHIN THE PARKING LOTS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
NOT F
OR
CONSTRUCTIO
N
B
IM
/1
.6
.0
U p d a te
W a y fi n d in g S ig n a g e
A E
.6
.0
A v
.r v t
/7
/2
:2
:3
P M
GI002
PROJECT OVERVIEW AND
SIGNAGE STANDARDSGUIDON DESIGN
1221 N. PENNSYLVANIA ST., STE. 200
INDIANAPOLIS, IN 46202
317.800.6388
UPDATE WAYFINDING - PARKING
SIGNAGE ON HINES CAMPUS
EDWARD HINES JR. VA HOSPITAL
19.6001.08
VARIES
03-08-24 TS LC
100% CONSTRUCTION
DOCUMENTS
WHITE
VA BLUE PANTONE 541
ALUMINUM
RED - EMERGENCY ONLY
PARKING ACCENT - B35 ANOLE GREEN
PATIENT PARKING AND VALET
PARKING ACCENT - B38 AQUA RIVA.
STAFF OR PATIENTS
PARKING ACCENT - B30 PURPLE PRINT.
ALL OTHER E.G. CONTRACTOR
VA BACKGROUND COLOR 'B3 LIME PEEL' GREEN -
MP12444'
EXTERIOR SIGNAGE COLOR LEGEND
NOTE: ALL COLORS ARE SCHEMATIC AND SHALL BE REVIEWED WITH OWNER PRIOR
TO MANUFACTURING.
4'
1' - 6 1/2"
2'
1'
1/
2"
1/ 2"
5"
W is co n si n
2 1/2" 3" 2 1/2"
Patient
Parking Only
PARKING LOT NAME, SEE SCHEDULE
4'
2' - 2"
6" 3"
2" 7"
1'
9" 9"
Parking Lot
1' - 1" 1' - 1"
H
PARKING LOT NAME, SEE SCHEDULE
PARKING LOT
INDICATOR. SEE
PLAN FOR LANE
SEQUENCING.
LEAVE BLANK IF NO
NUMBER
INDICATED. COLOR
MUST MATCH
PARKING LOT
COLOR
FRONT - PATIENT ONLYFRONT - STAFF OR PATIENT
VINYL BANNER
ATTACH TO
POSTS W/ POLE
MOUNTED RODS
BACKGROUND COLOR MUST MATCH
PARKING LOT COLOR
*NOTE: BANNER SIGNS ARE DOUBLE SIDED
BACKGROUND COLOR
MUST MATCH PARKING
LOT COLOR
1'
1'
/2
1' - 6 1/2"
1/
4" 1'
1/ 4"
9 1/4" 9 1/4"
BACKGROUND COLOR MUST MATCH
PARKING LOT COLOR
1'
1'
/2 " 1
1/
4" 1'
1/ 4"
9 1/4" 9 1/4"
4'
1' - 6 1/2"
2'
1'
1/
2"
1/ 2"
5"
W is co n si n
2 1/2"3"2 1/2"
Patient
Parking Only
PARKING LOT NAME, SEE SCHEDULE
OMIT FOR VALET
PARKING. TEXT TO
MATCH PARKING
COLOR
1'
1'
/2
1' - 6 1/2"
1/
4" 1'
1/ 4"
9 1/4"9 1/4"
4'
2' - 2"
6" 3"
2" 7"
1'
9" 9"
Parking Lot
1' - 1"1' - 1"
H
1'
1'
/2 "1
1/
4" 1'
1/ 4"
9 1/4"9 1/4"
PLAN VIEW
*NOTE: BANNER SIGNS SHALL BE
TRAFFIC FACING, 'N/S' TYPICAL, UON.
N
S
EW
SP-23.01 BANNER SIGNS
SPOT IDENTIFIER SIGNS
PLAN VIEW
*NOTE: BANNER SIGNS SHALL BE 'E-W'
IN LOTS: ALABAMA, CROSSMAN
CIRCLE, WISCONSIN, AND LOTS: C, G
N
S
EW
SPOT IDENTIFIER SIGNS
SP-23.01 BANNER SIGNS
*NOTE: PROVIDE 'SPOT IDENTIFIER' SIGNS BELOW BANNER
SIGNS ROTATED @ 90 DEGREES UON
BANNER SIGN INSTALLATION DIAGRAM
*NOTE: 'SPOT IDENTIFIER' SIGNS NOT
REQUIRED AT LOTS WITH ONLY A
SINGLE ROW: ALABAMA, ARKANSAS,
MISSOURI, IOWA, OKLAHOMA, LOTS E,
L, M, N, T, Q, R, S
SIDE
Patient Parking Only
1 3/4"
2' - 0"
3 1/4"
2"
2'
5'
1' - 0" 1' - 0"
Wisconsin 3"
3" 2"
6" 2"
2" 3"
Lot
FRONT - PATIENT ONLY
PARKING LOT NAME, SEE
SCHEDULE. CENTER TEXT
1 3/4"
2' - 0"
2'
5'
1' - 0" 1' - 0"
Parking Lot
4" 2"
2" 6"H
PARKING LOT NAME, SEE SCHEDULE.
CENTER TEXT
FRONT - STAFF OR PATIENT
1 3/4"
2' - 0"
2'
5'
1' - 0"
Valet
3" 3"
2"
Parking
FRONT - VALET
PARKING LOT NAME, SEE
SCHEDULE. CENTER TEXT
METAL POSTS
LASER CUT
ALUMINUM PANEL
ATTACH TO
POSTS W/
METAL
BRACKETS AND
BOLTS
BACKGROUND COLOR MUST
MATCH PARKING LOT COLOR
BACKGROUND COLOR MUST MATCH
PARKING LOT COLOR
BACKGROUND COLOR MUST MATCH
PARKING LOT COLOR
SIDE
1 3/4"
2' - 0"
3 1/4"
2"
2'
5'
1' - 0" 1' - 0"
Building
3" 3"
2" 6"
2" 2"
FRONT
METAL POSTS
LASER CUT ALUMINUM PANEL
ATTACH TO
POSTS W/
METAL
BRACKETS AND
BOLTS
2' - 0"
1'
Building
3" 3"
2" 6"
4"
1' - 0" 1' - 0"
LASER CUT ALUMINUM PANEL
*NOTE: ANCHOR BOLTS SHALL BE
PLACED INTO MORTAR JOINTS, NOT
BRICK DUE TO HISTORIC NATURE OF
BUILDINGS.
SIDE
1 3/4"
2' - 0"
3 1/4"
2"
2'
5'
1' - 0" 1' - 0"
Exit
3" 3"
2" 6"
2" 2"
FRONT
METAL POSTS
LASER CUT ALUMINUM PANEL
ATTACH TO
POSTS W/
METAL
BRACKETS AND
BOLTS
*NOTE: THIS SIGN
SHALL BE DOUBLE
SIDED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
NOT F
OR
CONSTRUCTIO
N
B
IM
/1
.6
.0
U p d a te
W a y fi n d in g S ig n a g e
A E
.6
.0
A v
.r v t
/7
/2
:2
:4
P M
GI008
SIGNAGE ELEVATIONS -
EXTERIOR GUIDES & PARKINGGUIDON DESIGN
1221 N. PENNSYLVANIA ST., STE. 200
INDIANAPOLIS, IN 46202
317.800.6388
UPDATE WAYFINDING - PARKING
SIGNAGE ON HINES CAMPUS
EDWARD HINES JR. VA HOSPITAL
19.6001.08
VARIES
03-08-24 TS LC
100% CONSTRUCTION
DOCUMENTS
Revisions: Date:
SCALE: 1 1/2" = 1'-0"GI008
1 SP-23.01A BANNER - POLE MOUNTED PARKING SIGN
SCALE: 1 1/2" = 1'-0"GI008
2 TYPE EN-03.06E - EXTERIOR NON-ILLUMINATED - POST MT PARKING SIGN
SCALE: 1 1/2" = 1'-0"GI008
5 TYPE EN-03.03C - EXTERIOR NON-ILLUMINATED - POST MT SECONDARY BUILDING ID & INFO
SCALE: 1 1/2" = 1'-0"GI008
4 TYPE EN-06.04A - EXTERIOR NON-ILLUMINATED - WALL MT SECONDARY BUILDING ID & INFO
SCALE: 1 1/2" = 1'-0"GI008
3 TYPE EN-03.03D - EXTERIOR NON-ILLUMINATED - POST MT DIRECTIONAL
NOTE: CONTRACTOR REFER TO LEGENDS FOR ACTUAL TEXT ON SIGNAGE. TEXT SHOWN IS SCHEMATIC OR A SINGLE EXAMPLE ONLY.
AI0-7PARK AI0-8PARK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
NOT F
OR
CONSTRUCTIO
N
B
IM
/1
.6
.0
U p d a te
W a y fi n d in g S ig n a g e
A E
.6
.0
A v
.r v t
/7
/2
:2
:3
P M
AI0-6PARK
EXTERIOR PARKING SIGNAGE
DRAWING OVERALLGUIDON DESIGN
1221 N. PENNSYLVANIA ST., STE. 200
INDIANAPOLIS, IN 46202
317.800.6388
UPDATE WAYFINDING - PARKING
SIGNAGE ON HINES CAMPUS
EDWARD HINES JR. VA HOSPITAL
19.6001.08
VARIES
03-08-24 TS LC
100% CONSTRUCTION
DOCUMENTS
Revisions: Date:
SCALE: 1/32" = 1'-0"AI0-6PARK
1 CAMPUS - PARKING - SIGNAGE DRAWING N
AI0-7PARK AI0-8PARK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
NOT F
OR
CONSTRUCTIO
N
B
IM
/1
.6
.0
U p d a te
W a y fi n d in g S ig n a g e
A E
.6
.0
A v
.r v t
/7
/2
:2
:3
P M
AI0-7PARK
EXTERIOR PARKING SIGNAGE
DRAWING ENLARGED 1GUIDON DESIGN
1221 N. PENNSYLVANIA ST., STE. 200
INDIANAPOLIS, IN 46202
317.800.6388
UPDATE WAYFINDING - PARKING
SIGNAGE ON HINES CAMPUS
EDWARD HINES JR. VA HOSPITAL
19.6001.08
VARIES
03-08-24 TS LC
100% CONSTRUCTION
DOCUMENTS
Revisions: Date:
SCALE: 3/64" = 1'-0"AI0-7PARK
1 CAMPUS - PARKING - SIGNAGE DRAWING ENLARGED 1 N
A I0
-8
PA
R K
A I0
-7
PA
R K
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
NOT F
OR
CONSTRUCTIO
N
B
IM
/1
.6
.0
U p d a te
W a y fi n d in g S ig n a g e
A E
.6
.0
A v
.r v t
/7
/2
:2
:3
P M
AI0-8PARK
EXTERIOR PARKING SIGNAGE
DRAWING ENLARGED 2GUIDON DESIGN
1221 N. PENNSYLVANIA ST., STE. 200
INDIANAPOLIS, IN 46202
317.800.6388
UPDATE WAYFINDING - PARKING
SIGNAGE ON HINES CAMPUS
EDWARD HINES JR. VA HOSPITAL
19.6001.08
VARIES
03-08-24 TS LC
100% CONSTRUCTION
DOCUMENTS
Revisions: Date:
SCALE: 3/64" = 1'-0"AI0-8PARK
1 CAMPUS - PARKING - SIGNAGE DRAWING ENLARGED 2
SCALE: 3/64" = 1'-0"AI0-8PARK
2 CAMPUS - PARKING - SIGNAGE DRAWING ENLARGED 3
N
N
| Sheets |
| GI000 - COVER SHEET |
| GI001 - ARCHITECTURAL SYMBOLS, NOTES, AND ABBREVIATIONS |
| GI002 - PROJECT OVERVIEW AND SIGNAGE STANDARDS |
| GI008 - SIGNAGE ELEVATIONS - EXTERIOR GUIDES & PARKING |
| AI0-6PARK - EXTERIOR PARKING SIGNAGE DRAWING OVERALL |
| AI0-7PARK - EXTERIOR PARKING SIGNAGE DRAWING ENLARGED 1 |
| AI0-8PARK - EXTERIOR PARKING SIGNAGE DRAWING ENLARGED 2 |
File details come from the government source that posted it. Updated .