This document contains product data and record drawings for Bioline dripline, a continuous self-cleaning, pressure compensating dripline specifically designed for wastewater applications. The product details include information on the dripper flow rates, pressure compensation range, tubing specifications, and flushing velocity requirements. It also includes ordering information and diagrams for Bioline fittings.

The document is related to a federal contract opportunity for site security improvements at the National Bio & Agro-Defense Facility in Manhattan, KS. The solicitation number is 12805B24R0036 and the contracting agency is the Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery Plains Area. The solicitation has a mandatory site visit on July 29th, and all RFI questions must be submitted by August 1, 2024. Responses to RFI questions will only be posted on sam.gov.

View the file

Other files

File Type Posted
12805B24R0036 Amendment 2.pdf PDF
Exhibit A REV 1- Bid Schedule - 12805B24R0036.xlsx XLSX spreadsheet
Solicitation 12805B24R0036 REV 2.pdf PDF
Attachment 19 Geotech Report.pdf PDF
12805B24R0036 Amendment 1.pdf PDF
Attachment 20 Questions from Industry.pdf PDF
Solicitation 12805B24R0036 REV 1.pdf PDF
Security Improvements Site Walk Sign in.pdf PDF
Attachment 5 CLIN B Drawings.pdf PDF
Attachment 2 CLIN A Drawings-PHASE 1.pdf PDF
Attachment 9 CLIN E Drawings.pdf PDF
Attachment 3 CLIN A Drawings-PHASE 2.pdf PDF
Attachment 13 Fillable Site Visit Application.pdf PDF
Attachment 10 CLIN G Specifications.pdf PDF
Attachment 16 ARS-372 Request for Payment.pdf PDF
Attachment 15 ARS-371 Construction Progress and Payment Schedule.pdf PDF
Attachment 7 CLIN D Drawings.pdf PDF
Attachment 11 CLIN G Drawings.pdf PDF
Attachment 4 CLIN B Specifications.pdf PDF
Exhibit A REV 0- Bid Schedule - 12805B24R0036.xlsx XLSX spreadsheet
Solicitation 12805B24R0036.pdf PDF
Attachment 6 CLIN D Specifications.pdf PDF
Attachment 8 CLIN E Specifications.pdf PDF
Attachment 14 Statement of Work.pdf PDF
Attachment 12 - Site Visit Information.docx DOCX document
Attachment 1 CLIN A Specifications.pdf PDF
Attachment 17 WD KS20240056 Mod 3 Dated 21 June 2024.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WASTEWATER DIVISION

PRODUCT ADVANTAGES

• Pressure compensation - all drippers deliver equal flow, even on sloped or rolling terrain.

• Unique flow path - Turbonet technology provides more control of water and a high resistance to clogging.

• Continuous self-flushing dripper design - flushes debris, as it is detected - throughout operation, not just at the beginning or end of a cycle. Ensures uninterrupted dripper operation.

• Single hole dripper outlet from tubing:

- Better protection against root intrusion

- Allows the dripline to be used in subsurface applications without need for chemical protection

• Drippers capture water flow from the center of the tubing - ensures that only the cleanest flow enters the dripper.

• Built-in physical root barrier - drippers are protected from root intrusion without the need for chemical protection. Water exits dripper in one location while exiting the tubing in another.

• Three dripper flow rates - provides the broadest range of flow rates available. Allows the designer to match the dripline to any soil or slope condition.

• Bioline tubing is completely wrapped in purple - easily identifying it for non-potable use, regardless of how the tubing is installed.

• Anti-bacterial-impregnated drippers - prevents buildup of microbial slime.

• Can be used subsurface - Bioline can be installed on-surface, under cover or subsurface.

• No special storage requirements - does not degrade if stored outdoors.

APPLICATIONS

• Typically installed following a treatment process

• Can be used with domestic septic tank effluent with proper design, filtration and operation

• Reuse applications including municipally treated effluent designated for irrigation and other disinfected and non-disinfected water sources.

SPECIFICATIONS

• Dripper flow rates: 0.4, 0.6 or 0.9 GPH

• Dripper spacings: 12”, 18” or 24” dripper spacings and blank tubing

• Pressure compensation range: 7 to 58 psi

• Maximum recommended system pressure:

58 psi

• Tubing diameter: 0.66” OD, 0.56” ID

• Tubing color: Purple color indicates non-potable

• Coil lengths: 500’ or 1,000’ (Blank tubing in

250’)

• Recommended filtration: 120 mesh

• Bending radius: 7”

• UV resistant

• Tubing material: Linear low-density polyethylene

Additional spacing and pipe sizes available by special order. Please contact Netafim USA Customer Service for details.

BIOLINE®

DRIPLINE

THE WORLD’S MOST ADVANCED CONTINUOUS

SELF-CLEANING, PRESSURE COMPENSATING DRIPLINE

SPECIFICALLY DESIGNED FOR WASTEWATER

CROSS SECTION

OF BIOLINE

DRIPLINE

Bioline dripper inlets are positioned in the center of flow where water is the cleanest

BIOLINE DRIPLINE

0.4 GPH

0.67/40

0.6 GPH

1.02/61

0.9 GPH

1.53/92

0.4 GPH

0.44/26.67

0.6 GPH

0.68/41

0.9 GPH

1.02/61

0.4 GPH

0.34/20

0.6 GPH

0.51/31

0.9 GPH

0.77/46

DRIPPER SPACING

MAXIMUM LENGTH OF A SINGLE LATERAL WITH 3.0 fps FLUSH VELOCITY

12” 18” 24”

DRIPPER FLOW RATE (GPH)

Flow per 100’ (GPM / GPH)

IN

LE

T

PR

ES

SU

RE

ADDITIONAL FLOW OF 2.3 GPM REQUIRED PER LATERAL TO ACHIEVE 3 fps

Lateral lengths are based on flows allowing for a 3 fps flushing/scouring velocity

0.4 GPH

0.67/40

0.6 GPH

1.02/61

0.9 GPH

1.53/92

0.4 GPH

0.44/26.67

0.6 GPH

0.68/41

0.9 GPH

1.02/61

0.4 GPH

0.34/20

0.6 GPH

0.51/31

0.9 GPH

0.77/46

DRIPPER SPACING

MAXIMUM LENGTH OF A SINGLE LATERAL WITH 2.5 fps FLUSH VELOCITY

12” 18” 24”

DRIPPER FLOW RATE (GPH)

Flow per 100’ (GPM / GPH)

IN

LE

T

PR

ES

SU

RE

ADDITIONAL FLOW OF 2.0 GPM REQUIRED PER LATERAL TO ACHIEVE 2.5 fps

Lateral lengths are based on flows allowing for a 2.5 fps flushing/scouring velocity

0.4 GPH

0.67/40

0.6 GPH

1.02/61

0.9 GPH

1.53/92

0.4 GPH

0.44/26.67

0.6 GPH

0.68/41

0.9 GPH

1.02/61

0.4 GPH

0.34/20

0.6 GPH

0.51/31

0.9 GPH

0.77/46

DRIPPER SPACING

MAXIMUM LENGTH OF A SINGLE LATERAL WITH 2.0 fps FLUSH VELOCITY

12” 18” 24”

DRIPPER FLOW RATE (GPH)

Flow per 100’ (GPM / GPH)

IN

LE

T

PR

ES

SU

RE

ADDITIONAL FLOW OF 1.6 GPM REQUIRED PER LATERAL TO ACHIEVE 2.0 fps

Lateral lengths are based on flows allowing for a 2 fps flushing/scouring velocity

Netafim recommends flushing velocities capable of breaking free any accumulated bioslimes and debris in the piping network.

Notes: 1. Refer to local regulations for information on flushing velocities that may be written into codes.

2. Netafim does not endorse a specific flushing velocity.

3. Flushing velocities should be determined based on regulations, quality of effluent, and type of flushing control.

4. Using a flushing velocity less than 1 fps does not provide turbulent flow as defined by Reynolds Number.

5. Higher flushing velocities provide more aggressive flushing.

0.4 GPH

0.67/40

0.6 GPH

1.02/61

0.9 GPH

1.53/92

0.4 GPH

0.44/26.67

0.6 GPH

0.68/41

0.9 GPH

1.02/61

0.4 GPH

0.34/20

0.6 GPH

0.51/31

0.9 GPH

0.77/46

DRIPPER SPACING

MAXIMUM LENGTH OF A SINGLE LATERAL WITH 1.5 fps FLUSH VELOCITY

12” 18” 24”

DRIPPER FLOW RATE (GPH)

Flow per 100’ (GPM / GPH)

IN

LE

T

PR

ES

SU

RE

ADDITIONAL FLOW OF 1.2 GPM REQUIRED PER LATERAL TO ACHIEVE 1.5 fps

Lateral lengths are based on flows allowing for a 1.5 fps flushing/scouring velocity

0.4 GPH

0.67/40

0.6 GPH

1.02/61

0.9 GPH

1.53/92

0.4 GPH

0.44/26.67

0.6 GPH

0.68/41

0.9 GPH

1.02/61

0.4 GPH

0.34/20

0.6 GPH

0.51/31

0.9 GPH

0.77/46

DRIPPER SPACING

MAXIMUM LENGTH OF A SINGLE LATERAL WITH 1.0 fps FLUSH VELOCITY

12” 18” 24”

DRIPPER FLOW RATE (GPH)

Flow per 100’ (GPM / GPH)

IN

LE

T

PR

ES

SU

RE

ADDITIONAL FLOW OF 0.8 GPM REQUIRED PER LATERAL TO ACHIEVE 1.0 fps

Lateral lengths are based on flows allowing for a 1 fps flushing/scouring velocity

0.4 GPH

0.67/40

0.6 GPH

1.02/61

0.9 GPH

1.53/92

0.4 GPH

0.44/26.67

0.6 GPH

0.68/41

0.9 GPH

1.02/61

0.4 GPH

0.34/20

0.6 GPH

0.51/31

0.9 GPH

0.77/46

DRIPPER SPACING

MAXIMUM LENGTH OF A SINGLE LATERAL WITH 0.5 fps FLUSH VELOCITY

12” 18” 24”

DRIPPER FLOW RATE (GPH)

Flow per 100’ (GPM / GPH)

IN

LE

T

PR

ES

SU

RE

ADDITIONAL FLOW OF 0.4 GPM REQUIRED PER LATERAL TO ACHIEVE 0.5 fps

Lateral lengths are based on flows allowing for a 0.5 fps flushing/scouring velocity

DRIPPER

SPACING

FLOW PER 100 FEET

GPM

12" 18” 24”

40.0 26.7 20.0

0.67 0.44 0.34

0.4 GPH DRIPPER

GPH GPM

61.0 41.0 31.0

1.02 0.68 0.51

0.6 GPH DRIPPER

GPH GPM

92.0 61.0 46.0

1.53 1.02 0.77

0.9 GPH DRIPPER

GPH

Large inlet filtration area (bottom of dripper)

Dripper’s Top View Top of dripper (turned over)

Chemical-resistant molded silicon diaphragm

TurboNet wide flow path

Dripper Outlet (top of dripper)

EXPLODED VIEW OF BIOLINE DRIPPER

Bottom View Top View

Physical barrier separates where water leaves the dripper from where it leaves the tubing.

SPECIFYING INFORMATION

BLANK Tubing Model Number: 250’ = 08WRAM-250

Bioline Dripline = 08WRAM

DRIPPER

FLOW RATE

DRIPPER

SPACING

COIL

LENGTH

1 2 3

A 1 32

A

0.4 GPH

0.6 GPH

0.9 GPH

= .4 = .6 = 1

12” 18” 24”

= 12 = 18 = 24

500’ 1,000’

= V500 = V

SAMPLE MODEL NUMBER

08WRAM.6-24 V

ORDERING INFORMATION

08WRAM.4-12V

08WRAM.4-12V500

08WRAM.4-18V

08WRAM.4-18V500

08WRAM.4-24V

08WRAM.4-24V500

08WRAM.6-12V

08WRAM.6-12V500

08WRAM.6-18V

08WRAM.6-18V500

08WRAM.6-24V

08WRAM.6-24V500

08WRAM1-12V

08WRAM1-12V500

08WRAM1-18V

08WRAM1-18V500

08WRAM1-24V

08WRAM1-24V500

08WRAM-250

1,000' 500'

1,000' 500'

1,000' 500'

1,000' 500'

1,000' 500'

1,000' 500'

1,000' 500'

1,000' 500'

1,000' 500'

250'

0.4 GPH

0.4 GPH

0.4 GPH

0.6 GPH

0.6 GPH

0.6 GPH

0.9 GPH

0.9 GPH

0.9 GPH

12"

18"

24"

12"

18"

24"

12"

18"

24"

Blank Tubing 17mm

FLOW

RATE

DRIPPER

SPACING

COIL

LENGTH

MODEL

NUMBER

BIOLINE DRIPPER OPERATION

Bioline® drippers are pressure compensating - delivering the water uniformly into the soil for further treatment or for reuse by the landscape. These unique drippers allow the tubing to be installed on flat topography or steep slopes.

Bioline drippers are protected against microbial slime.

Each dripper is impregnated with an antimicrobial agent to resist biological build-up.

Netafim drippers are continuously self-cleaning during operation, not just at the beginning and end of a cycle. The result is dependable, clog-free operation, year after year.

1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1

10 20 30 40 50 58

PRESSURE (psi)

FL

OW

R

AT

E (

GP

H)

DRIPPER FLOW RATE VS. PRESSURE

0.9 GPH

0.6 GPH

0.4 GPH

Between 0 and 7 psi, the dripper functions as a turbulent flow emitter, ensuring that the nominal design flow is not exceeded at system start-up.

NETAFIM USA

5470 E. Home Ave.

Fresno, CA 93727

CS 888 638 2346

www.netafimusa.com

W064 10/16

FITTING DEFINITIONS

FPT = Female Pipe Thread MPT = Male Pipe Thread Ins x Ins = Insert by Insert

BIOLINE FITTINGS

FITTING APPLICATIONS

• Fits Bioline Dripline

FITTING SPECIFICATIONS

• Barbed fittings for a secure fit

• Easy installation without glue or tools

• Allows for easy on-site inspection of proper fitting installation

TLS6

6” Soil Staple

TLSOV

Shut-Off Valve

Ins x Ins

TLCV

Inline Check Valve

TLCOUP

Insert Coupling

TLELL

Insert Elbow

TLTEE

Insert Tee

TLCROS

Insert Cross

TL050MA

½” Male Adapter

TL075MA

¾” Male Adapter

TL075FTEE

Combination Tee

Ins x Ins x ¾” FPT

TL2W075MA

2-Way Insert

¾” MPT x Insert

TLIAPE-B

Insert Adapter for 1” or

Larger PE (Requires 11mm or 7/16” drill or punch)

TLIAPVC-B

Insert Adapter with Grommet

1½” or larger PVC Pipe

TDBIT16.5

Drill Bit for TLIAPVC

Fitting (16.5mm or 21/32”)

TLFIG8

Figure 8 Line End

• Flow Range: 0.9 to 4.4 GPM

• Opening Pressure: 10.2 psi

• Closing Pressure: 5.8 psi

(13.4 Feet Column of Water)

NETAFIM USA 5470 E. HOME AVE., FRESNO, CA 93727 CS 888 638 2346 F 559 453 1043 WWW.NETAFIMUSA.COM

January 1, 2018

RE: Buy American Act – Made in the USA

To Whom It May Concern, Netafim Irrigation, Inc., is located in Fresno, California which was established in 1981. Netafim is the leading manufacturer of Drip and Micro irrigation products that service Agriculture, Greenhouse and Nursery, Landscape, Wastewater and Mining markets with solutions for water management and control for the various applications unique to each market.

Our dripline products are manufactured in Fresno, California where we employ nearly 200+ full time people.

Netafim Irrigation, Inc., is an American company and pays taxes in California and the United States of America.

These products are then distributed to the North American market that primarily includes the United States and

Canada.

The brand names Netafim UniRam™, DripNet PC™, Streamline Plus™, Typhoon Plus™ , Aries™ as well as Netafim

Techline® HCVXR, HCVXR-RW, HCVXR-RWP, CV, EZ, RW and RWP all qualify for regulations set forth in the

American Recovery and Reinvestment Act of 2009 by virtue of the location of the manufacturing facility, Fresno, California. Ancillary equipment such as fittings, valves, hydrometers, air vents and other components meet the terms of the agreement as detailed in Section § 176.90 Non-application to acquisition covered under international agreements. Where “the international agreement to treat the goods and services of a Party the same as domestic goods and services and the respective Parties to the agreements” and include the country Israel. Israel is the location of manufacture for all our ancillary products.

Please consider all of our products to qualify for the terms and conditions set forth in the American Recovery and

Reinvestment Act of 2009.

For additional product or technical information, feel free to contact us or visit us online at www.netafimusa.com.

Respectfully, Ze’ev Barylka Director of Marketing 559-453-6800

NETAFIM USA LEED®

STATEMENT JANUARY 2015

NETAFIM USA TUBING

MATERIALS AND RESOURCE CREDIT 4: RECYCLED CONTENT

WHAT IS LEED®:

The United States Green Building Council (USGBC) has been instrumental in the concept of creating a means to evaluate environmentally friendly (Green) buildings through a comprehensive series of Credit Points. The rating system is "Leadership in Energy and Environmental Design" commonly referred to as LEED. Information can be found at www.usgbc.org.

We wish to stress that LEED Credit Points are awarded to the building, not individual components or products. The components or products help in achieving points for the building, but are not rated by themselves. USGBC very explicitly "does not certify, endorse or promote products".

For this document, we are using the most up-to-date terminology and credit codes of LEED 2009.

NETAFIM USA PRODUCT CONTRIBUTION:

Netafim USA is a privately owned company located in Fresno, California which was established in 1981. Netafim USA is the leading manufacturer of drip and micro irrigation products that service Landscape, Agricultural, Greenhouse and Nursery, Wastewater, and Mining markets with solutions for water management and control for the various applications unique to each market.

Our products contribute to earning LEED points in the "Materials and Resources" MR Credit 4 "RECYCLED CONTENT" category. The intent is to increase demand for building products that incorporate recycled content materials, thereby reducing impacts resulting from extraction and processing of virgin materials. All products manufactured with recycled content meet our strict quality standards and provide the same high performance and long-life reliability.

This credit awards 1 point for a total recycled content (post-consumer + 1/2 pre-consumer) of 10% or 2 points for a total recycled content (post-consumer + 1/2 pre-consumer) of 20%. Points are based on weight then are multiplied by the cost of the assembly. As a manufacturer, the final cost of the assembly is not within our control; therefore our figures will be based on percentage by weight only.

Netafim USA’s Techline® , Techline® CV, Techline® RW and Techline® EZ and Polyethylene (PE) tubing product lines support qualification for earning 2 points in the LEED MR Credit 4 category. These product lines are produced with at least 20% recycled content that is comprised of a minimum of 5% post-consumer and 30% pre-consumer content.

Furthermore, Netafim USA owns and operates a polyethylene recycling plant in Fowler, California. Netafim Recycling collects and recycles plastic irrigation tubing primarily from agricultural installations in California. The used tubing is recycled to produce a recycled resin that is used in mining and landscape drip tubing applications. Netafim Recycling is a wholly owned subsidiary of Netafim USA of Fresno, California. It is through the process of collecting and re-manufacturing polyethylene drip tubing that Netafim USA is able to assure the highest quality of products and help customers qualify for credit toward LEED certification.

NETAFIM USA 5470 E. Home Ave. Fresno, CA 93727 CS (888) 638-2346 F (559) 453-6803 www.netafimusa.com

Product Data Drip Irrigation
Record Drawings

File details come from the government source that posted it. Updated .