This document contains product data and record drawings for Bioline dripline, a continuous self-cleaning, pressure compensating dripline specifically designed for wastewater applications. The product details include information on the dripper flow rates, pressure compensation range, tubing specifications, and flushing velocity requirements. It also includes ordering information and diagrams for Bioline fittings.
The document is related to a federal contract opportunity for site security improvements at the National Bio & Agro-Defense Facility in Manhattan, KS. The solicitation number is 12805B24R0036 and the contracting agency is the Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery Plains Area. The solicitation has a mandatory site visit on July 29th, and all RFI questions must be submitted by August 1, 2024. Responses to RFI questions will only be posted on sam.gov.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WASTEWATER DIVISION
PRODUCT ADVANTAGES
• Pressure compensation - all drippers deliver equal flow, even on sloped or rolling terrain.
• Unique flow path - Turbonet technology provides more control of water and a high resistance to clogging.
• Continuous self-flushing dripper design - flushes debris, as it is detected - throughout operation, not just at the beginning or end of a cycle. Ensures uninterrupted dripper operation.
• Single hole dripper outlet from tubing:
- Better protection against root intrusion
- Allows the dripline to be used in subsurface applications without need for chemical protection
• Drippers capture water flow from the center of the tubing - ensures that only the cleanest flow enters the dripper.
• Built-in physical root barrier - drippers are protected from root intrusion without the need for chemical protection. Water exits dripper in one location while exiting the tubing in another.
• Three dripper flow rates - provides the broadest range of flow rates available. Allows the designer to match the dripline to any soil or slope condition.
• Bioline tubing is completely wrapped in purple - easily identifying it for non-potable use, regardless of how the tubing is installed.
• Anti-bacterial-impregnated drippers - prevents buildup of microbial slime.
• Can be used subsurface - Bioline can be installed on-surface, under cover or subsurface.
• No special storage requirements - does not degrade if stored outdoors.
APPLICATIONS
• Typically installed following a treatment process
• Can be used with domestic septic tank effluent with proper design, filtration and operation
• Reuse applications including municipally treated effluent designated for irrigation and other disinfected and non-disinfected water sources.
SPECIFICATIONS
• Dripper flow rates: 0.4, 0.6 or 0.9 GPH
• Dripper spacings: 12”, 18” or 24” dripper spacings and blank tubing
• Pressure compensation range: 7 to 58 psi
• Maximum recommended system pressure:
58 psi
• Tubing diameter: 0.66” OD, 0.56” ID
• Tubing color: Purple color indicates non-potable
• Coil lengths: 500’ or 1,000’ (Blank tubing in
250’)
• Recommended filtration: 120 mesh
• Bending radius: 7”
• UV resistant
• Tubing material: Linear low-density polyethylene
Additional spacing and pipe sizes available by special order. Please contact Netafim USA Customer Service for details.
BIOLINE®
DRIPLINE
THE WORLD’S MOST ADVANCED CONTINUOUS
SELF-CLEANING, PRESSURE COMPENSATING DRIPLINE
SPECIFICALLY DESIGNED FOR WASTEWATER
CROSS SECTION
OF BIOLINE
DRIPLINE
Bioline dripper inlets are positioned in the center of flow where water is the cleanest
BIOLINE DRIPLINE
0.4 GPH
0.67/40
0.6 GPH
1.02/61
0.9 GPH
1.53/92
0.4 GPH
0.44/26.67
0.6 GPH
0.68/41
0.9 GPH
1.02/61
0.4 GPH
0.34/20
0.6 GPH
0.51/31
0.9 GPH
0.77/46
DRIPPER SPACING
MAXIMUM LENGTH OF A SINGLE LATERAL WITH 3.0 fps FLUSH VELOCITY
12” 18” 24”
DRIPPER FLOW RATE (GPH)
Flow per 100’ (GPM / GPH)
IN
LE
T
PR
ES
SU
RE
ADDITIONAL FLOW OF 2.3 GPM REQUIRED PER LATERAL TO ACHIEVE 3 fps
Lateral lengths are based on flows allowing for a 3 fps flushing/scouring velocity
0.4 GPH
0.67/40
0.6 GPH
1.02/61
0.9 GPH
1.53/92
0.4 GPH
0.44/26.67
0.6 GPH
0.68/41
0.9 GPH
1.02/61
0.4 GPH
0.34/20
0.6 GPH
0.51/31
0.9 GPH
0.77/46
DRIPPER SPACING
MAXIMUM LENGTH OF A SINGLE LATERAL WITH 2.5 fps FLUSH VELOCITY
12” 18” 24”
DRIPPER FLOW RATE (GPH)
Flow per 100’ (GPM / GPH)
IN
LE
T
PR
ES
SU
RE
ADDITIONAL FLOW OF 2.0 GPM REQUIRED PER LATERAL TO ACHIEVE 2.5 fps
Lateral lengths are based on flows allowing for a 2.5 fps flushing/scouring velocity
0.4 GPH
0.67/40
0.6 GPH
1.02/61
0.9 GPH
1.53/92
0.4 GPH
0.44/26.67
0.6 GPH
0.68/41
0.9 GPH
1.02/61
0.4 GPH
0.34/20
0.6 GPH
0.51/31
0.9 GPH
0.77/46
DRIPPER SPACING
MAXIMUM LENGTH OF A SINGLE LATERAL WITH 2.0 fps FLUSH VELOCITY
12” 18” 24”
DRIPPER FLOW RATE (GPH)
Flow per 100’ (GPM / GPH)
IN
LE
T
PR
ES
SU
RE
ADDITIONAL FLOW OF 1.6 GPM REQUIRED PER LATERAL TO ACHIEVE 2.0 fps
Lateral lengths are based on flows allowing for a 2 fps flushing/scouring velocity
Netafim recommends flushing velocities capable of breaking free any accumulated bioslimes and debris in the piping network.
Notes: 1. Refer to local regulations for information on flushing velocities that may be written into codes.
2. Netafim does not endorse a specific flushing velocity.
3. Flushing velocities should be determined based on regulations, quality of effluent, and type of flushing control.
4. Using a flushing velocity less than 1 fps does not provide turbulent flow as defined by Reynolds Number.
5. Higher flushing velocities provide more aggressive flushing.
0.4 GPH
0.67/40
0.6 GPH
1.02/61
0.9 GPH
1.53/92
0.4 GPH
0.44/26.67
0.6 GPH
0.68/41
0.9 GPH
1.02/61
0.4 GPH
0.34/20
0.6 GPH
0.51/31
0.9 GPH
0.77/46
DRIPPER SPACING
MAXIMUM LENGTH OF A SINGLE LATERAL WITH 1.5 fps FLUSH VELOCITY
12” 18” 24”
DRIPPER FLOW RATE (GPH)
Flow per 100’ (GPM / GPH)
IN
LE
T
PR
ES
SU
RE
ADDITIONAL FLOW OF 1.2 GPM REQUIRED PER LATERAL TO ACHIEVE 1.5 fps
Lateral lengths are based on flows allowing for a 1.5 fps flushing/scouring velocity
0.4 GPH
0.67/40
0.6 GPH
1.02/61
0.9 GPH
1.53/92
0.4 GPH
0.44/26.67
0.6 GPH
0.68/41
0.9 GPH
1.02/61
0.4 GPH
0.34/20
0.6 GPH
0.51/31
0.9 GPH
0.77/46
DRIPPER SPACING
MAXIMUM LENGTH OF A SINGLE LATERAL WITH 1.0 fps FLUSH VELOCITY
12” 18” 24”
DRIPPER FLOW RATE (GPH)
Flow per 100’ (GPM / GPH)
IN
LE
T
PR
ES
SU
RE
ADDITIONAL FLOW OF 0.8 GPM REQUIRED PER LATERAL TO ACHIEVE 1.0 fps
Lateral lengths are based on flows allowing for a 1 fps flushing/scouring velocity
0.4 GPH
0.67/40
0.6 GPH
1.02/61
0.9 GPH
1.53/92
0.4 GPH
0.44/26.67
0.6 GPH
0.68/41
0.9 GPH
1.02/61
0.4 GPH
0.34/20
0.6 GPH
0.51/31
0.9 GPH
0.77/46
DRIPPER SPACING
MAXIMUM LENGTH OF A SINGLE LATERAL WITH 0.5 fps FLUSH VELOCITY
12” 18” 24”
DRIPPER FLOW RATE (GPH)
Flow per 100’ (GPM / GPH)
IN
LE
T
PR
ES
SU
RE
ADDITIONAL FLOW OF 0.4 GPM REQUIRED PER LATERAL TO ACHIEVE 0.5 fps
Lateral lengths are based on flows allowing for a 0.5 fps flushing/scouring velocity
DRIPPER
SPACING
FLOW PER 100 FEET
GPM
12" 18” 24”
40.0 26.7 20.0
0.67 0.44 0.34
0.4 GPH DRIPPER
GPH GPM
61.0 41.0 31.0
1.02 0.68 0.51
0.6 GPH DRIPPER
GPH GPM
92.0 61.0 46.0
1.53 1.02 0.77
0.9 GPH DRIPPER
GPH
Large inlet filtration area (bottom of dripper)
Dripper’s Top View Top of dripper (turned over)
Chemical-resistant molded silicon diaphragm
TurboNet wide flow path
Dripper Outlet (top of dripper)
EXPLODED VIEW OF BIOLINE DRIPPER
Bottom View Top View
Physical barrier separates where water leaves the dripper from where it leaves the tubing.
SPECIFYING INFORMATION
BLANK Tubing Model Number: 250’ = 08WRAM-250
Bioline Dripline = 08WRAM
DRIPPER
FLOW RATE
DRIPPER
SPACING
COIL
LENGTH
1 2 3
A 1 32
A
0.4 GPH
0.6 GPH
0.9 GPH
= .4 = .6 = 1
12” 18” 24”
= 12 = 18 = 24
500’ 1,000’
= V500 = V
SAMPLE MODEL NUMBER
08WRAM.6-24 V
ORDERING INFORMATION
08WRAM.4-12V
08WRAM.4-12V500
08WRAM.4-18V
08WRAM.4-18V500
08WRAM.4-24V
08WRAM.4-24V500
08WRAM.6-12V
08WRAM.6-12V500
08WRAM.6-18V
08WRAM.6-18V500
08WRAM.6-24V
08WRAM.6-24V500
08WRAM1-12V
08WRAM1-12V500
08WRAM1-18V
08WRAM1-18V500
08WRAM1-24V
08WRAM1-24V500
08WRAM-250
1,000' 500'
1,000' 500'
1,000' 500'
1,000' 500'
1,000' 500'
1,000' 500'
1,000' 500'
1,000' 500'
1,000' 500'
250'
0.4 GPH
0.4 GPH
0.4 GPH
0.6 GPH
0.6 GPH
0.6 GPH
0.9 GPH
0.9 GPH
0.9 GPH
12"
18"
24"
12"
18"
24"
12"
18"
24"
Blank Tubing 17mm
FLOW
RATE
DRIPPER
SPACING
COIL
LENGTH
MODEL
NUMBER
BIOLINE DRIPPER OPERATION
Bioline® drippers are pressure compensating - delivering the water uniformly into the soil for further treatment or for reuse by the landscape. These unique drippers allow the tubing to be installed on flat topography or steep slopes.
Bioline drippers are protected against microbial slime.
Each dripper is impregnated with an antimicrobial agent to resist biological build-up.
Netafim drippers are continuously self-cleaning during operation, not just at the beginning and end of a cycle. The result is dependable, clog-free operation, year after year.
1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1
10 20 30 40 50 58
PRESSURE (psi)
FL
OW
R
AT
E (
GP
H)
DRIPPER FLOW RATE VS. PRESSURE
0.9 GPH
0.6 GPH
0.4 GPH
Between 0 and 7 psi, the dripper functions as a turbulent flow emitter, ensuring that the nominal design flow is not exceeded at system start-up.
NETAFIM USA
5470 E. Home Ave.
Fresno, CA 93727
CS 888 638 2346
www.netafimusa.com
W064 10/16
FITTING DEFINITIONS
FPT = Female Pipe Thread MPT = Male Pipe Thread Ins x Ins = Insert by Insert
BIOLINE FITTINGS
FITTING APPLICATIONS
• Fits Bioline Dripline
FITTING SPECIFICATIONS
• Barbed fittings for a secure fit
• Easy installation without glue or tools
• Allows for easy on-site inspection of proper fitting installation
TLS6
6” Soil Staple
TLSOV
Shut-Off Valve
Ins x Ins
TLCV
Inline Check Valve
TLCOUP
Insert Coupling
TLELL
Insert Elbow
TLTEE
Insert Tee
TLCROS
Insert Cross
TL050MA
½” Male Adapter
TL075MA
¾” Male Adapter
TL075FTEE
Combination Tee
Ins x Ins x ¾” FPT
TL2W075MA
2-Way Insert
¾” MPT x Insert
TLIAPE-B
Insert Adapter for 1” or
Larger PE (Requires 11mm or 7/16” drill or punch)
TLIAPVC-B
Insert Adapter with Grommet
1½” or larger PVC Pipe
TDBIT16.5
Drill Bit for TLIAPVC
Fitting (16.5mm or 21/32”)
TLFIG8
Figure 8 Line End
• Flow Range: 0.9 to 4.4 GPM
• Opening Pressure: 10.2 psi
• Closing Pressure: 5.8 psi
(13.4 Feet Column of Water)
NETAFIM USA 5470 E. HOME AVE., FRESNO, CA 93727 CS 888 638 2346 F 559 453 1043 WWW.NETAFIMUSA.COM
January 1, 2018
RE: Buy American Act – Made in the USA
To Whom It May Concern, Netafim Irrigation, Inc., is located in Fresno, California which was established in 1981. Netafim is the leading manufacturer of Drip and Micro irrigation products that service Agriculture, Greenhouse and Nursery, Landscape, Wastewater and Mining markets with solutions for water management and control for the various applications unique to each market.
Our dripline products are manufactured in Fresno, California where we employ nearly 200+ full time people.
Netafim Irrigation, Inc., is an American company and pays taxes in California and the United States of America.
These products are then distributed to the North American market that primarily includes the United States and
Canada.
The brand names Netafim UniRam™, DripNet PC™, Streamline Plus™, Typhoon Plus™ , Aries™ as well as Netafim
Techline® HCVXR, HCVXR-RW, HCVXR-RWP, CV, EZ, RW and RWP all qualify for regulations set forth in the
American Recovery and Reinvestment Act of 2009 by virtue of the location of the manufacturing facility, Fresno, California. Ancillary equipment such as fittings, valves, hydrometers, air vents and other components meet the terms of the agreement as detailed in Section § 176.90 Non-application to acquisition covered under international agreements. Where “the international agreement to treat the goods and services of a Party the same as domestic goods and services and the respective Parties to the agreements” and include the country Israel. Israel is the location of manufacture for all our ancillary products.
Please consider all of our products to qualify for the terms and conditions set forth in the American Recovery and
Reinvestment Act of 2009.
For additional product or technical information, feel free to contact us or visit us online at www.netafimusa.com.
Respectfully, Ze’ev Barylka Director of Marketing 559-453-6800
NETAFIM USA LEED®
STATEMENT JANUARY 2015
NETAFIM USA TUBING
MATERIALS AND RESOURCE CREDIT 4: RECYCLED CONTENT
WHAT IS LEED®:
The United States Green Building Council (USGBC) has been instrumental in the concept of creating a means to evaluate environmentally friendly (Green) buildings through a comprehensive series of Credit Points. The rating system is "Leadership in Energy and Environmental Design" commonly referred to as LEED. Information can be found at www.usgbc.org.
We wish to stress that LEED Credit Points are awarded to the building, not individual components or products. The components or products help in achieving points for the building, but are not rated by themselves. USGBC very explicitly "does not certify, endorse or promote products".
For this document, we are using the most up-to-date terminology and credit codes of LEED 2009.
NETAFIM USA PRODUCT CONTRIBUTION:
Netafim USA is a privately owned company located in Fresno, California which was established in 1981. Netafim USA is the leading manufacturer of drip and micro irrigation products that service Landscape, Agricultural, Greenhouse and Nursery, Wastewater, and Mining markets with solutions for water management and control for the various applications unique to each market.
Our products contribute to earning LEED points in the "Materials and Resources" MR Credit 4 "RECYCLED CONTENT" category. The intent is to increase demand for building products that incorporate recycled content materials, thereby reducing impacts resulting from extraction and processing of virgin materials. All products manufactured with recycled content meet our strict quality standards and provide the same high performance and long-life reliability.
This credit awards 1 point for a total recycled content (post-consumer + 1/2 pre-consumer) of 10% or 2 points for a total recycled content (post-consumer + 1/2 pre-consumer) of 20%. Points are based on weight then are multiplied by the cost of the assembly. As a manufacturer, the final cost of the assembly is not within our control; therefore our figures will be based on percentage by weight only.
Netafim USA’s Techline® , Techline® CV, Techline® RW and Techline® EZ and Polyethylene (PE) tubing product lines support qualification for earning 2 points in the LEED MR Credit 4 category. These product lines are produced with at least 20% recycled content that is comprised of a minimum of 5% post-consumer and 30% pre-consumer content.
Furthermore, Netafim USA owns and operates a polyethylene recycling plant in Fowler, California. Netafim Recycling collects and recycles plastic irrigation tubing primarily from agricultural installations in California. The used tubing is recycled to produce a recycled resin that is used in mining and landscape drip tubing applications. Netafim Recycling is a wholly owned subsidiary of Netafim USA of Fresno, California. It is through the process of collecting and re-manufacturing polyethylene drip tubing that Netafim USA is able to assure the highest quality of products and help customers qualify for credit toward LEED certification.
NETAFIM USA 5470 E. Home Ave. Fresno, CA 93727 CS (888) 638-2346 F (559) 453-6803 www.netafimusa.com
| Product Data Drip Irrigation |
| Record Drawings |
File details come from the government source that posted it. Updated .