This document is a set of technical drawings and specifications for the Bushy Knoll Pit Crush and Stockpile project located in Coconino National Forest, Coconino County, Arizona, managed by the United States Department of Agriculture Forest Service, Southwestern Region (R3).

The project involves the development of a pit site for aggregate extraction, crushing, and stockpiling operations. Key requirements include: completion of topographic surveys prior to, during, and post-operations for measurement and payment purposes; contractor responsibility for obtaining all necessary permits including ADEQ Air Quality Permit and Notice of Intention (NOI) with SWPPP and erosion control plans; pit expansion allowance continuing southeast of the indicated operational area; minimum 10-foot deep initial drilling entry; maximum 2:1 slope for existing and new slopes; and stockpile side slopes no flatter than 1V:1.5H. All aggregate produced must meet Forest Service Supplemental Specification Section 703.05 requirements for surface course aggregate with "R3-G" gradation per Forest Service Supplemental Specification Table 703-1, including sieve size requirements ranging from 1 inch (100% passing) to No. 200 (7-19% passing) and a Plasticity Index of 4-10. Additional requirements include aggregate with maximum 10% flat and elongated particles, vehicle barriers constructed from oversized boulders with 36-inch maximum spacing, one 50-gallon or two 30-gallon spill kits on-site, compliance with FP-24 Section 205 for rock blasting, and delivery of topographic survey data in AutoCAD 2022 format or other COR-approved format. Access road construction follows Standard Specifications for Construction of Roads and Bridges on Federal Highway Projects (FP-24 U.S. Customary Units) with roadway typicals including 12-16 foot traveled ways and 4-inch minimum compacted aggregate surface depth. The contract includes provisions for seasonal operational restrictions during breeding season (March 1 to September 1) if federally threatened or endangered species are present within 0.5 miles.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOREST LOCATION MAP

PAGE OF1 5

RECOMMENDED BY:

APPROVED:

FOREST ENGINEER

DISTRICT RANGER DATE

DATE

DIRECTOR OF ENGINEERING DATE

FOREST SUPERVISOR DATE

RO FACILITIES PROGRAM MANAGER DATE

INDEX OF SHEETS

SHEET SHEET TITLE DATE

G-01 COVER SHEET 3/22/2026

G-02 GENERAL NOTES 3/22/2026

C-01 PROPOSED SITE PLAN 3/22/2026

C-02 ROADWAY TYPICALS 3/22/2026

C-03 DRAINAGE DIP TYPICALS 3/22/2026

N/A

N/A

N/A

N/A

N/A

N/A

N/A N/A

PROJECT LOCATION MAP

TRAVEL DIRECTIONS:

From Flagstaff travel south on Lake Mary Road for 45.4 miles. Turn left onto COC-211. Continue for 1.3 miles and turn left onto NFSR 211D. Destination will be on the right in 0.4 miles.

UNITED STATES DEPARTMENT OF AGRICULTURE

FOREST SERVICE

BUSHY KNOLL PIT

CRUSH AND STOCKPILE

(R3) SOUTHWESTERN REGION

COCONINO NATIONAL FOREST

COCONINO COUNTY

ARIZONA

FLAGSTAFF

BUSHKY

KNOLL PIT

Map Data (C) 2026 Google

GENERAL NOTES:

1. IF FEDERALLY THREATENED/ENDANGERED SPECIES, FOREST SERVICE SENSITIVE

SPECIES, OR BALD OR GOLDEN EAGLES ARE NESTING WITHIN THE VICINITY OF 0.5

MILES OF THE PROJECT AREA, THEN SEASONAL RESTRICTIONS TO OPERATIONS ARE

EFFECTIVE DURING THE BREEDING SEASON (MARCH 1 TO SEPTEMBER 1) TO PREVENT

DISTURBANCE OF THE AFFECTED SPECIES. AT THIS TIME, THERE ARE NO KNOWN

IMPACTS.

2. PROPOSED PIT SITE LOCATIONS AND DIMENSIONS ARE APPROXIMATE AND WILL BE

FURTHER IDENTIFIED IN THE FIELD BY THE COR.

3. PIT EXPANSION WILL BE ALLOWED IN THIS CONTRACT AND WILL CONTINUE TO

SOUTHEAST OF THE INDICATED OPERATIONAL AREA AS SHOWN IN THE SITE PLAN

MAP ON SHEET C-01.

4. CONTRACTOR SHALL COMPLETE A TOPOGRAPHIC SURVEY OF SITE PRIOR TO DURING

AND POST OPERATIONS. SURVEY IS REQUIRED FOR MEASURMENT AND PAYMENT.

THE SURVEY SHALL BE PERFORMED BY A LICENSED AND INSURED COMPANY AND

PAID UNDER LINE ITEM 154 IN THE SCHEDULE OF ITEMS.

5. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FOR

THIS TYPE OF CONSTRUCTION, INCLUDING ANY ASSOCIATED FEES. ADEQ AIR

QUALITY PERMIT AND NOI (INCLUDING A SWPPP AND EROSION CONTROL PLAN) ARE

REQUIRED.

6. THE CONTRACTOR IS RESPONSIBLE FOR THEIR OWN SECURITY. A TEMPORARY

FENCE AND GATE CAN BE INSTALLED AND REMOVED UPON COMPLETION OF THE

CONTRACT.

7. THE BOTTOM OF THE PIT SHALL SLOPE A MINIMUM OF 1% TO PROVIDE POSITIVE

DRAINAGE. ALL EXISTING SLOPES AND ANY NEW SLOPES CREATED DURING

OPERATIONS SHALL BE LAID AT A MAXIMUM 2:1 SLOPE.

8. ALL EXISTING SLOPES AND ANY NEW SLOPES CREATED DURING OPERATIONS SHALL

BE LAID AT A MAXIMUM 2:1 SLOPE.

9. STOCKPILE SIDE SLOPES SHALL BE NO FLATTER THAN 1V:1.5H AND SHALL BE

STOCKPILED IN ACCORDANCE WITH FP-24 SECTION 314.05.

10. ALL AGGREGATE PRODUCED SHALL MEET THE REQUIREMENTS UNDER FSSS SECTION

703.05 FOR SURFACE COURSE AGGREGATE. GRADATION OF STOCKPILE SHALL BE

"R3-G" PER FOREST SERVICE SUPPLEMENTAL SPECIFICATION TABLE 703-1. SEE

SHEET C-01.

11. AGGREGATE SHALL HAVE A MAXIMUM OF 10% FLAT AND ELONGATED PARTICLES. IF

APPARENT FLAT AND ELONGATED PARTICLES ARE OBSERVED IN THE MATERIAL. THE

CONTRACTOR SHALL HAVE THE MATERIAL TESTED FOR FLAT AND ELONGATED

PARTICLES AT THE REQUEST OF THE COR PER ASTM D4791 (1:3 RATIO, PLUS 3/8"

SIEVE, CALCULATED BY MASS, WEIGHTED AVERAGE) AT THE CONTRACTOR'S

EXPENSE.

12. THERE IS NO MOISTURE CONTENT REQUIREMENT FOR STOCKPILED AGGREGATE.

13. THE CONTRACTOR IS ALLOWED TO CAMP AT THE SITE DURING THE

CONSTRUCTION PERIOD. THIS MAY REQUIRE A DISTRICT ISSUED CAMPING PERMIT

AT NO COST.

14. NO GOVERNMENT WATER SOURCE IS AVAILABLE AT BUSHY KNOLL PIT.

15. CLEARING AND GRUBBING MAY BE REQUIRED IF ADDITIONAL EXPANSION FOR THE

PIT DEVELOPMENT IS NECESSARY. ALL REFUSE FROM THIS OPERATION SHALL BE

PILED IN LOCATIONS DESIGNATED BY THE COR.

16. MERCHANTABLE TIMBER AS DEFINED BY THE UTILIZATION STANDARDS SHALL BE

HANDLED ACCORDING TO FSSS SECTION 201 AND ALL APPLICABLE SUPPLEMENTS

AND DECKED IN LOCATIONS DESIGNATED BY THE COR.

17. THE CONTRACTOR WILL COMPLY WITH FP-24 SECTION 205, ROCK BLASTING,

DURING BLASTING OPERATIONS.

18. THE CONTRACTOR SHALL PLAN FOR 10 FT DEEP ENTRY FOR INITIAL DRILLING (MIN).

THE PROPOSED FOOTPRINT CAN BE MODIFIED AS NECESSARY TO ACCOMMODATE

THIS DEPTH.

19. ALL EXISTING OVERSIZED BOULDERS SHALL BE UTILIZED FOR A VEHICLE BARRIER

AND/OR AGGREGATE PRODUCTION PRIOR TO ANY ROCK BLASTING/ROCK

EXCAVATION AND/OR PIT EXPANSION WITH APPROVAL FROM THE COR. THE

VEHICLE BARRIER SHALL BE PLACED AT ENTRANCE LOCATIONS OF THE PROJECT

SITE DESIGNATED BY THE COR. SPACE BETWEEN THE OVERSIZED BARRIER

MATERIAL SHALL NOT EXCEED 36 INCHES.

20. ALL ADDITIONAL OVERSIZED MATERIAL THAT IS NOT USED TO CREATE A VEHICLE

BARRIER, REGARDLESS OF SIZE, SHALL BE REDUCED TO A MAXIMUM SIZE OF

2'X2'X2' THROUGHOUT THE PROJECT SITE.

21. PROTECT IN PLACE ALL EXISTING EQUIPMENT ON SITE, INCLUDING THE GATE AT

THE JUNCTION OF COC-211 AND NFSR 211D.

22. ONE 50 GALLON SPILL KIT OR TWO 30 GALLON SPILL KITS MUST BE LOCATED

ON-SITE DURING USE OF HEAVY EQUIPMENT.

23. CONSTRUCTION OF PROPOSED ROAD IS INCIDENTAL TO PIT DEVELOPMENT PAY

ITEM 651(01). ACCESS ROAD SHALL BE CONSTRUCTED USING THE STANDARD

SPECIFICATIONS FOR CONSTRUCTION OF ROADS AND BRIDGES ON FEDERAL

HIGHWAY PROJECTS (FP-24 U.S. CUSTOMARY UNITS) AS WELL AS APPLICABLE

SUPPLEMENTAL SPECIFICATIONS.

24. THE SITE TOPOGRAPHIC SURVEY DATA SHALL BE DELIVERED TO THE

GOVERNMENT IN THE FOLLOWING FORM: AUTOCAD 2022 SURFACE FILE, OR OTHER

FORMAT APPROVED BY THE COR, CLEARLY STATING THE ANALYZED VOLUME OF

THE STOCKPILE AND VISUALLY REPRESENTATIVE OF THE STOCKPILE THAT WAS

ANALYZED.

DRAWING TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

5/4 /26

:2

9 T

NC

ON

NO

LL

Y C

:\U

SE

RS

\T

NC

ON

NO

LL

Y\

BO

X\

E

NG

IN

EE

RI

NG

(C

OC

)\7

0 G

EO

TE

CH

MA

TE

RI

AL

SE

NG

EE

RI

NG

\B

US

HY

K

NO

LL

\20

\1.

P

RE

P\

6.

AC

AD

-D

W

GS

A

ND

P

DF

M

AP

S

PL

AN

S\

BU

SH

Y

KN

OL

L

.D W

G

R3

SOUTHWESTERN REGION

BUSHY KNOLL PIT

CRUSH AND

STOCKPILE

COCONINO

NATIONAL FOREST

MOGOLLON RIM

RANGER DISTRICT

GENERAL NOTES

3/22/2026

T. CONNOLLY

T. CONNOLLY

S. UNTALAN

G-02

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

GRADATION SPEC

SIEVE SIZE

Percent by Mass Passing

Designated Sieve (1)

(AASHTO T 27 & T

11)

1 inch 100

3/4 inch 97-100

3/8 inch 66-87

No. 4 43-66

No. 16 23-44

No. 40 14-31

No. 200 7-19

Plasticity Index (PI)* 4-10

GRADATION OF STOCKPILE SHALL BE

"R3-G" PER FOREST SERVICE

SUPPLEMENTAL SPECIFICATION TABLE

703-1.

DRAWING TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

5/4 /26

:2

9 T

NC

ON

NO

LL

Y C

:\U

SE

RS

\T

NC

ON

NO

LL

Y\

BO

X\

E

NG

IN

EE

RI

NG

(C

OC

)\7

0 G

EO

TE

CH

MA

TE

RI

AL

SE

NG

EE

RI

NG

\B

US

HY

K

NO

LL

\20

\1.

P

RE

P\

6.

AC

AD

-D

W

GS

A

ND

P

DF

M

AP

S

PL

AN

S\

BU

SH

Y

KN

OL

L

.D W

G

R3

SOUTHWESTERN REGION

BUSHY KNOLL PIT

CRUSH AND

STOCKPILE

COCONINO

NATIONAL FOREST

MOGOLLON RIM

RANGER DISTRICT

PROPOSED SITE PLAN

AND GRADATION

SPEC

03/22/2026

T. CONNOLLY

T. CONNOLLY

S. UNTALAN

C-01

*Imported bentonite can be added to meet the specification. If less than 4 PI then add 2% bentonite by weight.

(1) Statistical procedures do not apply.

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

NATURAL GROUND

ROAD TEMPLATE

TRAVELED WAY

12' MIN - 16' MAX

TYPICAL CROSS-SECTION WITH AGGREGATE SURFACING

AND WITHOUT ROADWAY DITCH

CLEARING WIDTH*

*CLEARING LIMITS WILL BE WHICHEVER IS

GREATER: SHOULDER +6 FT OR HEEL/TOE OF

SLOPE +3 FT.

' M

IN

4" MIN. COMPACTED DEPTH

4 +/- 1% OUTSLOPE

TYPICAL CROSS-SECTION WITH AGGREGATE SURFACING

AND ROADWAY DITCH

NATURAL GROUND

4" MIN. COMPACTED DEPTH

ROAD TEMPLATE

4 +/- 1% INSLOPE

TRAVELED WAY

12' MIN - 16' MAX

3'

1'

' M

IN

TYPICAL CROSS-SECTION WITH AGGREGATE SURFACING,

CROWN, AND ROADWAY DITCH

CLEARING WIDTH*

' M

IN

TRAVELED WAY

12' MIN - 16' MAX

4 +/- 1% 4 +/- 1%

NATURAL GROUND

ROAD TEMPLATE

4" MIN. COMPACTED DEPTH

3'

1'

3:1, 2:1 MAX

*CLEARING LIMITS WILL BE WHICHEVER IS

GREATER: SHOULDER +6 FT OR HEEL/TOE OF

SLOPE +3 FT.

TYPICAL ROADWAY

DITCH

CLEARING WIDTH*

TYPICAL ROADWAY

DITCH

*CLEARING LIMITS WILL BE WHICHEVER IS

GREATER: SHOULDER +6 FT OR HEEL/TOE OF

SLOPE +3 FT.

INTERSECTION GRADING AND SHAPING

INTERSECTING ROAD

4" AGGREGATE SURFACE

DITCH FLOW LINE

CL

MAINTAIN EXISTING DITCH FLOW LINES

TO ENSURE POSITIVE DRAINAGE AWAY

FROM THE EXISTING INTERSECTING

ROAD.

R O

AD

W

ID

TH

3:1 , 2

:1

MAX

3:1 , 2

:1

MAX 3:1, 2:1 MAX

3:1, 2:1 MAX

DRAWING TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

5/4 /26

:2

9 T

NC

ON

NO

LL

Y C

:\U

SE

RS

\T

NC

ON

NO

LL

Y\

BO

X\

E

NG

IN

EE

RI

NG

(C

OC

)\7

0 G

EO

TE

CH

MA

TE

RI

AL

SE

NG

EE

RI

NG

\B

US

HY

K

NO

LL

\20

\1.

P

RE

P\

6.

AC

AD

-D

W

GS

A

ND

P

DF

M

AP

S

PL

AN

S\

BU

SH

Y

KN

OL

L

.D W

G

R3

SOUTHWESTERN REGION

BUSHY KNOLL PIT

CRUSH AND

STOCKPILE

COCONINO

NATIONAL FOREST

MOGOLLON RIM

RANGER DISTRICT

ROADWAY TYPICALS

03/22/2026

T. CONNOLLY

T. CONNOLLY

S. UNTALAN

C-02

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

10% MAX

12% MAX

10% MAX

ROAD GRADE LINE

SUBGRADE

0.5-2.5'

NOT TO SCALE

GRAVEL SURFACE

AB B

A

TOE

(H) INSIDE

10'

10'

START

DIP

END

DIP

CREST

DITCH/BOTTOM

MIDPOINT

DRAIN LINE

0-10% ANGLE

(H) OUTSIDE

L

STATIONED ON PLANS

P

4 +/-1%

DOWN

GRADE

ROLLING DIP NOTES:

1. THE CROSS SLOPE OF THE ROADBED SHALL BE MAINTAINED

THROUGH THE DIP.

2. THE DRAIN LINE SHALL BE SKEWED OFF OF THE ROADBED TO

ALLOW POSITIVE DRAINAGE, UNLESS OTHERWISE FLAGGED.

3. FOR DIPS ON AGGREGATE SURFACE ROADS, ADD DEPTH OF

COMPACTED SURFACE TO DIMENSION (H).

4. ALL DITCHES ASSOCIATED WITH DRAINAGE DIP STRUCTURES SHALL

BE MAINTAINED WITHIN THE PROJECT SITE.

5. DIRECTION OF EXISTING WATER FLOW SHALL BE MAINTAINED.

NOT TO SCALE

DRAINAGE DIP CONSTRUCTION DIMENSIONS

TYPE "1"

%GRADE

LENGTH DEPTH (H)

A B OUTSIDE

EDGE

INSIDE

EDGE

0-4% 18 55 0.9' 0.4' 5-8% 16 85 0.8' 0.3' 9-12% 15 110 0.7' 0.3'

DRAINAGE DIP

PERSPECTIVE

DRAINAGE DIP

PROFILE

DRAWING TITLE

PROJECT NAME

DRAWN

DESIGNER

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DWG SHEET NO.

OFSHEET

United States Department of Agriculture Forest Service

5/4 /26

:2

9 T

NC

ON

NO

LL

Y C

:\U

SE

RS

\T

NC

ON

NO

LL

Y\

BO

X\

E

NG

IN

EE

RI

NG

(C

OC

)\7

0 G

EO

TE

CH

MA

TE

RI

AL

SE

NG

EE

RI

NG

\B

US

HY

K

NO

LL

\20

\1.

P

RE

P\

6.

AC

AD

-D

W

GS

A

ND

P

DF

M

AP

S

PL

AN

S\

BU

SH

Y

KN

OL

L

.D W

G

R3

SOUTHWESTERN REGION

BUSHY KNOLL PIT

CRUSH AND

STOCKPILE

COCONINO

NATIONAL FOREST

MOGOLLON RIM

RANGER DISTRICT

DRAINAGE DIP

TYPICALS

03/22/2026

T. CONNOLLY

T. CONNOLLY

S. UNTALAN

C-03

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

Sheets and Views
Bushy Knoll 2026-COVER
Bushy Knoll 2026-GEN NOTES
OLE1
Bushy Knoll 2026-SITE PLAN
OLE1
Bushy Knoll 2026-ROADWAY TYPICALS
Bushy Knoll 2026-DRAINAGE DIP TYPICALS

File details come from the government source that posted it. Updated .