This document is a Service Record for a generator maintenance service performed by CD Power for the Forest Service on 8/11/25. The service was conducted on a 230DFAB generator (Serial No: F990929000) located at 1323 Club Dr, with technician Luis L Cardenas performing the maintenance. Key service details include: oil changed, air filter inspected, fuel filter replaced, and oil filter changed. The generator was in good operating condition, though notes indicate batteries are over 4 years old and a load bank is recommended. Systems tests showed the generator ran for 20 minutes, with no-load source readings of 482 voltage and 60.0 hertz. The technician noted the unit is smoking through the exhaust and recommended a load bank test. Additional compliance checks were performed, including fuel sample, transfer switch inspection, and exhaust system evaluation.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Service Record

DID YOU KNOW? WE ALSO PROVIDE THE FOLLOWING:

Sales • Rentals • Installa�on • Service • IR Scanning • UPS • Green Power Op�ons

925.229.2700 916.564.2622 866.468.7697 Emergency Service 24/7

Rev. 8.14.24-rj

Date of Service:

Customer Name:

WO/

Doc #:

Loca�on/

ID:

Generator/ Equipment:

Serial No:

Service Technician:

Unit Placed in Off Posi�on at Start of Service:

Yes No

Engine

Oil Added __________ Changed

Inspected

Air Filter Yes No N/A Inspected

Cleaned

Coolant Added __________ Changed Test Strip Reading _____________

Hour Meter Working:

Yes No

Hour Meter Upon Arrival: Hour Meter A�er:

Indicate (if changed):

Air Filter Spark Plugs Points Fuel Filter Rotor Condenser Oil Filter Cap

Rate on a scale of 1 to 3 (1=Excellent, 2=Fair, 3=Poor) Spark Plug Wires

Fuel Lines

Oil Lines

Gov Coolant Hoses

Block Heater

Blk Htr Hose

Control Panel

Fuel Tank

Fuel Radiator Turbo Belts Water Pump

Radiator Cap

Remote Annunciator

Generator Rate on a scale of 1 to 3 (1=Excellent, 2=Fair, 3=Poor) Control Box

Overall Condi�on

Visual Inspec�on for signs of heat and wear

Generator Wipe Down Yes No & Clean of Debris

Accessories Fuel Supply Level: Diesel Fuel Treated

Yes No With Condi�oner?

Batery Test: Pass Fail Batery

Date:

Fuel Visual Inspec�on Pass Fail Batery Changed: Yes No

Rate on a scale of 1 to 3 (1=Excellent, 2=Fair, 3=Poor) Terminals Cables Batery

Charger Se�ng Mounts Housing Hydrometer

Reading:

Transfer Switch Visual Inspec�on of ATS:

Yes No Heat and Wear:

Yes No Batery Replacement Date:

(Date on Batery)

Bateries Changed: Yes No

Exercise Clock: Yes No Date: Time: Dura�on:

Systems Test Startup First Time? Yes No Generator Run Time Dura�on? Transfer Test Explained/Offered? Yes No

Voltage Hertz Amps Oil Pressure Temp No-Load Source Reading:

With Load Reading:

Exhaust System Visual Inspec�on: Yes No Rain Cap: Yes No Petcock Valve? Yes No Drained: Yes No

Overall Appearance: Any Significant Leaks? Yes No Access? Yes No Ven�la�on: Yes No

Compliance Is Breaker “ON” Yes No If no, state and in “AUTO”? reason why --------------------------------------------------------------------------------------------------------

Fuel Sample Yes No N/A Taken? NFPA 110

Unit Remote Yes No Monitored?

Rupture Basin Yes No Unknown N/A Test? CFC5003

SPCC Plan? Yes No Unknown N/A

Does Facility Have Yes No A Diesel Fire Pump?

Does CD&P Perform Yes No Service on Pump?

Does Facility Have Yes No

A UPS?*

Hazardous Fluids Yes No Removed From Site?

Tank Inspec�on? Yes No Unknown N/A

STISP001

PTO Reviewed? Yes No N/A

AQMD

Log Book Yes No N/A on Site?

PTO Onsite? Yes No Pictures Taken Yes No If Repairs Suggested? (if yes, see Parts Req.)

Parts Req. Filled Yes No Out if Repairs Are Suggested?

Notes: (Missing Items or Concerns)

*If yes (facility has UPS), send picture to mtzservicepaperwork@gotpower.com

Attachment: 1.1

Rebekah Line

Rebekah Line

Date of Service: 8/11/25
Customer Name: Forest Service
WO Doc: 126232
Locaon ID: 1323 Club Dr
Generator Equipment: 230DFAB
Serial No: F990929000
Service Technician: Luis L Cardenas
Changed: On
Inspected: Yes
undefined_3: Off
undefined_4: Off
Cleaned: Off
undefined_5: 1/2 Gallon
Reading: Ok
Hour Meter Working: Yes_2
Hour Meter Upon Arrival: 673.6
Hour Meter Aer: 673.9
Air Filter: Off
Spark Plugs: Off
undefined_6: Off
Fuel Filter: On
undefined_7: Off
Condenser: Off
Oil Filter: On
undefined_8: Off
Spark Plug Wires:
Fuel Lines: 2
Oil Lines: 2
Gov: 1
Coolant Hoses: 2
Block Heater: 1
Blk Htr Hose: 2
Control Panel: 1
Fuel Tank: 1
Fuel: 1
Radiator: 1
Turbo: 2
Belts: 2
Water Pump: 2
Radiator Cap: 1
Remote Annunciator:
Control Box: 1
Overall Condion: 2
Visual Inspecon for signs of heat and wear: Yes
Fuel Supply Level: 7?8 Full
undefined_11: Off
Batery Date: 7/21
Terminals: 2
Cables: 2
Batery Charger: 1
Seng: 1
Mounts: 2
Housing: 2
Hydrometer Reading: Ok
Batery Replacement Date:
Date:
Time:
Duraon:
Generator Run Time Duraon: 20 minutes
VoltageNoLoad Source Reading: 482
HertzNoLoad Source Reading: 60.0
AmpsNoLoad Source Reading:
Oil PressureNoLoad Source Reading: 37 psi
TempNoLoad Source Reading: 179*F
VoltageWith Load Reading:
HertzWith Load Reading:
AmpsWith Load Reading:
Oil PressureWith Load Reading:
TempWith Load Reading:
Visual Inspecon: Yes_3
Rain Cap: Yes_4
Petcock Valve: No_11
Drained: Off
fill_90: Ok
undefined_13: No_13
undefined_14: Yes_8
Venlaon: Yes_9
reason why:
Oil: Off
Added:
Check Box1: Yes
Check Box2: Off
Check Box3: Yes
Check Box4: Off
Check Box5: Off
Check Box6: Yes
Check Box7: Off
Check Box8: Off
Check Box9: Off
Check Box10: Off
Check Box11: Yes
Check Box12: Off
Check Box13: Off
Check Box14: Yes
Check Box15: Off
Check Box16: Off
Check Box17: Off
Check Box18: Yes
Check Box19: Off
Check Box20: Yes
Check Box21: Yes
Check Box22: Off
Check Box23: Off
Check Box24: Off
Check Box25: Off
Check Box26: Yes
Check Box27: Off
Check Box28: Yes
Check Box29: Off
Text30: Unit in good operating conditions. Note!! Batteries over 4 years old.
Text31: Load bank recommended, unit smoking trough the exaust.
Text32:
Check Box33: Off
Check Box34: Off
Check Box35: Off
Check Box36: Yes
Check Box37: Off
Check Box38: Off
Check Box39: Off
Check Box40: Off
Check Box41: Yes
Check Box42: Off
Check Box43: Off
Check Box44: Off
Check Box45: Off
Check Box46: Off
Check Box47: Off
Check Box48: Off
Check Box49: Yes
Check Box50: Off
Check Box51: Off
Check Box52: Yes
Check Box53: Off
Check Box54: Off
Check Box55: Off
Check Box56: Yes
Check Box57: Off
Check Box58: Off
Check Box59: Yes
Check Box60: Off
Check Box61: Off
Check Box62: Yes
Check Box63: Off
Check Box64: Off
Check Box67: Off
Check Box68: Off

File details come from the government source that posted it. Updated .