This document is a set of architectural plans and work notes for the renovation of the Stockmore Office/Garage building located in Duchesne County, Utah, on the Ashley National Forest, administered by the United States Department of Agriculture Forest Service, R4 Intermountain Region.

The project encompasses demolition and remodeling work across multiple areas of the facility. Demolition activities include removal of exterior doors and frames in Office #2, windows in Office #2, bathroom fixtures and plumbing in both men's and women's restrooms, Office #2 closet doors and track systems, bathroom fans and lights, and light fixtures throughout the garage, office areas, closets, and hallway. The contractor must verify all utility locations including electric, gas, water, drain lines, electrical panel, and venting. Remodeling work includes installation of two new vinyl windows in Office #2 with exterior vinyl trim, two new commercial insulated steel doors and frames in Office #2 with Schlage Chrome keyed entry handles, installation of a Kwikset Smartcode 917 keypad entry door in the garage, keyed commercial door handles on the garage closet, and vinyl exterior trim around all existing windows. Interior work includes patching and painting all sheetrock and plywood walls to Level 3 finish in eggshell paint for walls and ceilings and semi-gloss for doors and trim, installation of 4-inch rubber wall base, and luxury vinyl plank flooring in two offices, two restrooms, and closets. Electrical work comprises removal and replacement of fluorescent fixtures with 18 new LED wraparound fixtures in the garage, 4 new LED fixtures in hallway and closets, 14 new fixtures in Office #1 and 5 in Office #2, 3 new exterior LED flood lights at door locations, installation of 3 new electrical receptacles at workbench height in the garage with galvanized conduit, and 4 additional receptacles in Office #2 with in-wall conduit. Restroom remodeling includes reversing door swings, installing American Standard Edgemere elevated toilets in both restrooms, 36-inch vanities with Project Source Davies Oak and cultured marble tops with Moen Lindor faucets, an American Standard wall-mounted urinal in the men's room, commercial vinyl sheet flooring with 4-inch flash coving, GFCI outlets in both restrooms, and Broan Nu-Tone 50 CFM bathroom fan and light fixtures with new wiring to light switches.

View the file

Other files for this federal contract opportunity

Other files attached to Stockmore Admin Site Renovation, newest first.
File Type Posted
C04b - SOW - SPECS - 1240LT26Q0135.pdf PDF
C05 SF30 - P0001 - 1240LT26Q0135.pdf PDF
C04a - Schedule of Items - 1240LT26Q0135.xlsx XLSX spreadsheet
C04c - Drawings - 1240LT26Q0135.pdf PDF
C04 SF1442 - 1240LT26Q0135 - Final.pdf PDF
C04a - Schedule of Items - 1240LT26Q0135.xlsx XLSX spreadsheet
C04d - Experience Questionnaire 1240LT26Q0135.docx DOCX document
C04e Past Performance Data Sheet 1240LT26Q013.docx DOCX document
C04b - SOW - SPECS - 1240LT26Q0135.pdf PDF
C04f - WD UT20260079 - 5-18-2026 1240LT26Q0135.txt TXT text file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VICINITY MAP

United States Department of Agriculture Forest Service

5/1 3/2

6 1 2:

C

AT

HL

EE

NC

HR

IS

TE

NS

EN

C

:\U

SE

RS

\C

AT

HL

EE

NC

HR

IS

TE

NS

EN

\B

OX

\01

. C

AT

HL

EE

NC

HR

IS

TE

NS

EN

W

OR

KS

PA

CE

\A

LL

P

RP

OJ

EC

TS

D

DU

CH

ES

NE

\20

S

TO

CK

MO

RE

O

FF

IC

E

RE

NO

VA

TI

ON

\20

S

TO

CK

M

OR

E

RE

NO

VA

TI

ON

\C

OV

ER

SH

EE

T

UI

NT

AH

G

S.

DW

G

STOCKMORE OFFICE/GARAGE

BUILDING RENOVATIONS

UTAH

DUCHESNE COUNTY

ASHLEY NATIONAL FOREST

R4 INTERMOUNTAIN REGION

TRAVEL DIRECTIONS:

FROM THE CITY OF DUCHESNE, UTAH, HEAD NORTH ON NORTH CENTER STREET (UT-87).

TRAVEL FOR APPROX 6 MILES ON UT-87. TAKE WEST STATE ROAD UT-35 AND TRAVEL 20

MILES. THE STOCKMORE BUILDING IS AT THE INTERSECTION OF UT-35 AND THE FORK ROAD.

ALTONAH.

PROJECT LOCATION

NATIONAL MAP

RECOMMENDED BY:

FOREST ENGINEER

INDEX OF SHEETS

S H E E T

SHEET TITLE

COVERSHEET

VICINITY MAP

DEMOLITION PLAN

REMODEL PLAN

ELECTRICAL WORK NOTES

BATHROOM REMODEL WORK NOTES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

S

T O

C K

M O

R E

B

L D

G

R

E M

O D

E L

AutoCAD SHX Text

DRAWING

AutoCAD SHX Text APPROVED:%%u %%u DATE %%u

AutoCAD SHX Text

FILE NAME & EXT.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

DESIGN

AutoCAD SHX Text U. S. Department of Agriculture

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text Manti-LaSal National Forest Engineering

AutoCAD SHX Text

BY:

AutoCAD SHX Text

CHECK:

AutoCAD SHX Text

BY:

AutoCAD SHX Text

CHECK:

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text D

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

VICINITY MAP

AutoCAD SHX Text

NATIONAL FOREST

NATIONAL FOREST

STOCKMORE OFFICE/GARAGE DEMO WORK NOTES:

REMOVE AND DISPOSE OF 2 EXTERIOR DOORS AND FRAMES IN OFFICE #2

REMOVE AND DISPOSE OF 2 WINDOWS IN OFFICE #2

REMOVE AND DISPOSE OF BATHROOM FIXTURES AND RELATED PLUMBING IN MEN'S AND WOMEN'S BATHROOM (TOILET,VANITY, SINK, URINAL). REMOVE AND

SALVAGE RESTROOM DOORS TO BE RE-INSTALLED WITH REVERSE SWING. SEE SHEET 6 FOR RESTROOM REMODEL NOTES

REMOVE AND DISPOSE OF OFFICE #2 CLOSET DOORS AND TRACK SYSTEM

REMOVE AND DISPOSE OF BATHROOM FANS AND LIGHTS

OPTION #1 WORK NOTE: REMOVE AND DISPOSE OF LIGHT FIXTURES IN GARAGE, OFFICE AREAS, CLOSETS, AND HALLWAY. SALVAGE FLUORESCENT LIGHT

TUBES. SEE ELECTRICAL PLAN FOR NEW LIGHT FIXTURE LOCATIONS ON SHEET 5

NOTE: CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING THE UTILITY LOCATIONS (ELECTRIC, GAS, WATER, DRAIN LINES, ELECTRIC PANEL, VENTING, ETC).

GARAGE AREA

MENS

RESTROOM

OFFICE #2

GARAGE

CLOSET #2

OFFICE #1GARAGE

CLOSET #1

WOMENS

RESTROOM

HALLWAY

C L O

S E

T

GARAGE OVERHEAD DOOR

CAPPED

PLUMBING

FURNACE

WH

70'

24'

CAPPED

PLUMBING

CAPPED

PLUMBING

O

C K

M O

D

G

R

E M

O D

E L

AutoCAD SHX Text

DRAWING

AutoCAD SHX Text APPROVED:%%u %%u DATE %%u

AutoCAD SHX Text

FILE NAME & EXT.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

DESIGN

AutoCAD SHX Text U. S. Department of Agriculture

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text Manti-LaSal National Forest Engineering

AutoCAD SHX Text

BY:

AutoCAD SHX Text

CHECK:

AutoCAD SHX Text

BY:

AutoCAD SHX Text

CHECK:

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text D

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DEMO PLAN

AutoCAD SHX Text

NATIONAL FOREST

STOCKMORE OFFICE/GARAGE REMODEL WORK NOTES:

INSTALL 2 NEW VINYL WINDOWS IN OFFICE #2. EXISTING SLIDER WINDOWS ARE APPROX. 48" X 36". INSTALL EXTERIOR VINYL TRIM ON NEW WINDOWS. SEE WINDOW SPECS FOR

APPROVED BRAND NAMES

INSTALL NEW VINYL EXTERIOR TRIM AROUND ALL EXISTING VINYL WINDOWS. SEE PHOTO OF EXISTING WINDOW ON SHEET 6

INSTALL 2 NEW EXTERIOR COMMERCIAL INSULATED STEEL DOORS AND FRAMES AND NECESSARY HARDWARE IN OFFICE #2. EXISTING DOORS ARE 36" X 80". PAINT DOORS AND FRAME WITH SEMI GLOSS ENAMEL PAINT. INSTALL MODEL SCHLAGE CHROME EXTERIOR KEYED ENTRY DOOR HANDLE AS SOLD BY LOWES

INSTALL KEY PAD ON MAN ENTRY DOOR IN GARAGE. MODEL KWIKSET SMARTCODE 917 BATTERY OPERATED PROGRAMMABLE KEYPAD WITH HANDLE OR APPROVED EQUAL.

INSTALL KEYED COMMERCIAL DOOR HANDLE ON GARAGE CLOSET #2 DOOR. INSTALL MODEL SCHLAGE CHROME EXTERIOR KEYED ENTRY DOOR HANDLE OR APPROVED EQUAL.

REMODEL MENS AND WOMENS RESTROOM. SEE RESTROOM REMODEL WORK NOTES ON SHEET 6

OPTION #1 - WORK NOTES: PATCH HOLES AND ROUGH AREAS OF ALL SHEETROCK AND PLYWOOD WALLS PRIOR TO PAINTING. PRIME AND PAINT INTERIOR WALLS, CEILING, DOORS, AND SHELVING FOR ALL AREAS INSIDE BUILDING. CEILING AND WALLS SHALL BE PAINTED WITH THE SAME COLOR, EGGSHELL PAINT. DOORS AND DOOR/WINDOW TRIM SHALL BE PAINTED WITH AN ENAMEL SEMI GLOSS PAINT. PAINTING ON WALLS AND CEILINGS SHALL B E TO A LEVEL 3 FINISH. INSTALL NEW 4 INCH RUBBER WALL BASE AFTER PAINTING.

COLORS SHALL BE SELECTED BY COR.

OPTION #2 - INSTALL WATERPROOF LUXURY VINYL PLANK (LVP). SMARTCORE MODEL OR APPROVED EQUAL. FLOORING IN 2 OFFICES, 2 RESTROOMS, OFFICE #2 CLOSET AND HALLWAYS. FLOAT FLOOR AS NECESSARY OVER THE EXISTING RESILIENT TILE FLOORING TO OBTAIN A SMOOTH FINISH FOR THE NEW FLOORING. INSTALL LVP AS MANUFACTURER'S

RECOMMENDATIONS. COR SHALL SELECT COLOR AND PATTERN

OPTION #3 - INSTALL A WATER COOLER/BOTTLE FILLER AT THE PREVIOUS WATER COOLER LOCATION IN GARAGE. INSTALL ELKAY MODEL OR APPROVED EQUAL.

NOTE: CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING THE CONDITION OF BUILDING AND THE UTILITY LOCATIONS (ELECTRIC, GAS, WATER, DRAIN LINES, ELECTRIC PANEL, VENTING, ETC).

MENS

RESTROOM

WOMENS

RESTROOM

C

LO

SE

T

A

B

C

D

F

A

A

C

C

D

F

F

GARAGE AREA

OFFICE #2

OFFICE #1

HALLWAY

GARAGE OVERHEAD DOOR

FURNACE WH

E

B B B B B B

B

B

B B

E GARAGE

CLOSET #2

GARAGE

CLOSET #1

F

WATER

COOLER

LOCATION

O

C K

M O

R E

B U

IL

D

IN

G

R E

N O

V A

T

IO

N

AutoCAD SHX Text

DRAWING

AutoCAD SHX Text APPROVED:%%u %%u DATE %%u

AutoCAD SHX Text

FILE NAME & EXT.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

DESIGN

AutoCAD SHX Text U. S. Department of Agriculture

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text Manti-LaSal National Forest Engineering

AutoCAD SHX Text

BY:

AutoCAD SHX Text

CHECK:

AutoCAD SHX Text

BY:

AutoCAD SHX Text

CHECK:

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text D

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

REMODEL PLAN

AutoCAD SHX Text

NATIONAL FOREST

OPTION #1 - STOCKMORE OFFICE/GARAGE ELECTRICAL LIGHTING WORK NOTES (DOES NOT INCLUDE RESTROOM ELECTRICAL WORK):

REMOVE AND DISPOSE OF FLUORESCENT LIGHT FIXTURES IN GARAGE. SALVAGE BULBS AND EXISTING WIRING. INSTALL 18 NEW LED LIGHT FIXTURES IN GARAGE AREA TO REPLACE PREVIOUS LIGHTING.

INSTALL NEW LIGHT FIXTURES MODEL LITHONIA LIGHTING 4 FT 6000 LUMEN LED WRAPAROUND LIGHT AS SOLD BY LOWES.

REMOVE AND DISPOSE OF 4 LIGHT FIXTURES IN HALLWAY AND GARAGE CLOSETS. SALVAGE BULBS AND EXISTING WIRING. INSTALL INSTALL 4 NEW INTERIOR LIGHT FIXTURES IN HALLWAY AND GARAGE

CLOSETS TO REPLACE PREVIOUS LIGHTING. NEW LIGHT FIXTURES MODEL LITHONIA LIGHTING 4 FT 4-FOOT 6000 LUMEN LED WRAPAROUND LIGHT

REMOVE AND DISPOSE OF FLUORESCENT LIGHT FIXTURES IN OFFICE #1 AND OFFICE #2. SALVAGE BULBS AND EXISTING WIRING. INSTALL 14 NEW INTERIOR LIGHT FIXTURES IN OFFICE #1 AND INSTALL 5

NEW INTERIOR LIGHT FIXTURES IN OFFICE #2. CAP UNUSED WIRING IN OFFICE #2 WITH ELECTRICAL COVER PLATES. NEW LIGHTS WILL REPLACE PREVIOUS LIGHTING. NEW LIGHT FIXTURES MODEL

LITHONIA LIGHTING 4 FT 4-FOOT 6000 LUMEN LED WRAPAROUND LIGHT

INSTALL 3 NEW EXTERIOR LIGHTS AT EXTERIOR DOOR LOCATIONS. NEW LIGHT FIXTURE MODEL 34W 3500 LUMEN LED FLOOD LIGHT OUTDOOR DUSK TO DAWN. EXISTING ELECTRICAL WIRING EXISTS AT

TWO LIGHT FIXTURE LOCATIONS IN FRONT OF BUILDING. NEW WIRING INSTALLATION WORK AND SWITCH FOR NEW EXTERIOR LIGHT IS NEEDED ON THE BACK OF THE BUILDING

INSTALL 10 NEW ELECTRICAL RECEPTACLES AT WORK BENCH HEIGHT (APPROX. 40 INCHES HIGH) IN THE GARAGE AREA. GALVANIZED CONDUIT SHALL BE SURFACE MOUNTED ON WALL. EXISTING

ELECTRICAL OUTLETS TO REMAIN. SEE THIS SHEET FOR NEW LOCATIONS

INSTALL 4 NEW ADDITIONAL ELECTRICAL RECEPTACLES IN OFFICE #2. CONDUIT SHALL BE INSIDE WALLS. REPAIR ANY DAMAGE TO SHEETROCK DURING INSTALLATION. SEE THIS SHEET FOR NEW

LOCATIONS

NOTE: CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING THE EXISTING CONDITION OF BUILDING AND THE UTILITY LOCATIONS (ELECTRIC, GAS, WATER, DRAIN LINES, ELECTRIC PANEL, VENTING, ETC).

GARAGE AREA

MENS

RESTROOM

OFFICE #2

CLOSET

OFFICE #1

CLOSET

WOMENS

RESTROOM

HALLWAY

C L O

S E

T

FURNACE

WH

1 1 1

O

C K

M O

U I L D

I N

G

R

E N

O V

A T

I O

N

AutoCAD SHX Text

DRAWING

AutoCAD SHX Text APPROVED:%%u %%u DATE %%u

AutoCAD SHX Text

FILE NAME & EXT.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

DESIGN

AutoCAD SHX Text U. S. Department of Agriculture

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text Manti-LaSal National Forest Engineering

AutoCAD SHX Text

BY:

AutoCAD SHX Text

CHECK:

AutoCAD SHX Text

BY:

AutoCAD SHX Text

CHECK:

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text D

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ELECTRICAL PLAN

AutoCAD SHX Text

NATIONAL FOREST

RESTROOM REMODELING WORK NOTES:

REVERSE DOOR SWINGS IN BOTH RESTROOMS TO MATCH REMODELING PLAN. INSTALL DOOR STOPS ON WALL

INSTALL AND PLUMB NEW TOILETS MODEL AMERICAN STANDARD EDGEMERE ELEVATED CHAIR HEIGHT IN BOTH RESTROOMS. ENSURE THIS MODEL OF

TOILET WILL FIT IN RESTROOM

FOR WOMENS RESTROOM, INSTALL NEW 36-INCH VANITY MODEL PROJECT SOURCE DAVIES OAK WITH CULTURED MARBLE TOP/SINK AS SOLD BY LOWES.

INSTALL A 4 INCH BACKSPLASH USING SIMILAR MATERIALS AND COLOR. INSTALL AND PLUMB FAUCET MODEL MOEN LINDOR BRUSHED NICKEL WIDESPREAD

2-HANDLE WITH DRAIN. AS SOLD BY LOWES

FOR MENS RESTROOM, INSTALL NEW 30-INCH VANITY MODEL PROJECT SOURCE DAVIES OAK WITH CULTURED MARBLE TOP/SINK AS SOLD BY LOWES.

INSTALL A CORNER AND BACKSPLASH USING SIMILAR MATERIALS AND COLOR. INSTALL AND PLUMB FAUCET MODEL MOEN LINDOR BRUSHED NICKEL

WIDESPREAD 2-HANDLE WITH DRAIN. AS SOLD BY LOWES

INSTALL AND PLUMB NEW URINAL MODEL AMERICAN STANDARD WALL MOUNTED URINAL IN MEN'S ROOM. ENSURE NEW MODEL WILL MATCH EXISTING

PLUMBING

REWIRE EXISTING LIGHT SWITCHES TO NEW LOCATIONS AS SHOWN ON THIS REMODELING PLAN. CONDUIT SHALL BE WITHIN WALLS

INSTALL COMMERCIAL VINYL SHEET FLOORING WITH 4 INCH FLASH COVING. SEE SPECIFICATIONS ON APPROVED SUPPLIERS. COR SHALL SELECT PATTERN

AND COLOR

REPLACE EXISTING ELECTRICAL RECEPTACLES WITH GFCI OUTLET IN BOTH RESTROOMS

INSTALL NEW BATH FANS MODEL BROAN NU-TONE 50 CFM WHITE BATHROOM FAN AND LIGHT FIXTURE MODEL PROJECT SOURCE 15-INCH ROUND LED LIGHT

FIXTURES IN BOTH RESTROOMS. PREVIOUS FANS WERE WIRED TO LIGHT SWITCH

NOTE: CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING THE UTILITY LOCATIONS (ELECTRIC, GAS, WATER, DRAIN LINES, ELECTRIC PANEL, VENTING, ETC).

WOMENS

RESTROOM

MENS

RESTROOM

HALLWAY

S

GFCI

GFCI

S

EXISTING WINDOWS THAT REQUIRE

TRIM WORK INSTALLATION

O

C K

M O

D

G

R

E M

O D

E L

AutoCAD SHX Text

DRAWING

AutoCAD SHX Text APPROVED:%%u %%u DATE %%u

AutoCAD SHX Text

FILE NAME & EXT.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

DESIGN

AutoCAD SHX Text U. S. Department of Agriculture

AutoCAD SHX Text

FOREST SERVICE

AutoCAD SHX Text Manti-LaSal National Forest Engineering

AutoCAD SHX Text

BY:

AutoCAD SHX Text

CHECK:

AutoCAD SHX Text

BY:

AutoCAD SHX Text

CHECK:

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text D

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

RESTROOM REMODEL AND PHOTO OF EXISTING WINDOW

AutoCAD SHX Text

NATIONAL FOREST

2026-07-30T09:11:19-0600
CATHLEEN CHRISTENSEN

File details come from the government source that posted it. Updated .