About this file
This document is the Standard Specifications for Construction of Trails and Trail Bridges on Forest Service Projects, issued by the National Technology and Development Program on October 30, 2014, superseding the 1996 standard. It provides comprehensive technical requirements for designing, fabricating, and constructing prefabricated fiber-reinforced polymer (FRP) composite trail bridges and associated trail infrastructure on federal forest lands.
The specifications establish detailed engineering and design requirements for FRP trail bridges, including pedestrian loads of 90 psf, vehicle loads ranging from 10,000 lbs (H5) to 20,000 lbs (H10) based on deck width, deflection limits of L/360, and fundamental frequency requirements of 5.0 Hz vertically and 3.0 Hz horizontally to avoid harmonic issues. Structural design must comply with AASHTO LRFD Bridge Design Specifications and be performed by licensed professional engineers in Colorado. The bridge manufacturer must have minimum five years of experience with three reference projects in service for at least three years. Material specifications require FRP fabrication from high-strength E-glass and isophthalic polyester resin with minimum material strengths of 33,000 psi for tension, compression, and bending, and 2,800,000 psi Young's modulus. Additional requirements address decking materials (treated Douglas Fir or Southern Pine), hardware specifications (A307 hot-dipped galvanized steel), tolerances (1/16 inch for fabrication), delivery with 14-day notice, temporary storage with 8-inch ground clearance, assembly instructions for component shipments, and a 15-year warranty covering structural integrity of FRP materials and workmanship. The specifications also include comprehensive sections on materials for timber structures, geosynthetics, pipe, aggregate, fencing, and gabion/revet mattress systems applicable to trail construction projects.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Appendix III: Little Snake River – Elkhorn Trail Bridge Project Specifications
STANDARD
SPECIFICATIONS FOR
CONSTRUCTION OF
TRAILS AND TRAIL
BRIDGES ON
FOREST SERVICE
PROJECTS
U.S. Customary Units
National Technology and Development Program
10/30/2014
Supersedes the 1996 Standard Specification for Construction and Maintenance of Trails
10/30/2014 Trail Specifications-1
Table of Contents
Section
900. General Requirements
901. Terms, Format, Abbreviations, and Definitions
902. Intent of Contract
903. Control of Work
904. Control of Materials
905. Quality Assurance and Quantity of Measurement
906. Measurement and Payment
907. Mobilization
908. Construction Survey, Staking, Flagging and Cleanup
909. Maintenance for Traffic and Temporary Construction Access
909.10 Maintenance for Traffic
909.20 Temporary Construction Access
Construction Specifications
910 – 950 Removed (Not Applicable)
960. Trail Bridges
961.00 - 966.00 Removed (Not Applicable)
969. Reserved for Trail Bridge Special Project Specifications
969.10. Prefabricated FRP Trail Bridge
970 – 980 Removed (Not Applicable)
990. Material
991.00. Rock, Grid Pavement Unit, Aggregate and Asphalt
991.01 Rock
991.02 Gabion and Revet Mattress Rock
991.03 Grid Pavement Unit
991.04 Pit-Run Aggregate
991.05 Screened Aggregate
991.06 Crushed Aggregate for Base or Surface Course
991.07 Asphalt
991.08 Cement
992.00. Pipe Material
993.00. Fence Material
994.00. Geosynthetic Material
994.01 Geotextile
994.02 Geonet
994.03 Geogrid
994.04 Geocell
994.05 Sheet Drains
10/30/2014 Trail Specifications-2
995.00. Material for Timber Structures
996.00. Gabion and Revet Mattress Material
10/30/2014 Trail Specifications-3
Section 900 General Specifications
10/30/2014 Trail Specifications-4
Section 901—Terms, Format, Abbreviations and Definitions
901.01 Meaning of Terms. These specifications are generally written in the imperative mood. In sentences using the imperative mood, the subject “the Contractor,” is implied. Also implied in this language is “shall,” “shall be,” or similar words or phrases. In material specifications, the subject may also be the supplier, fabricator, or manufacturer supplying material, products, or equipment for use on the project.
Wherever “directed,” “required,” “prescribed,” or similar words are used, the “direction,” “requirement,” or “order” of the Contracting Officer is intended.
Similarly, wherever “approved,” “acceptable,” suitable,” “satisfactory,” or similar words are used, they mean “approved by,” “acceptable to,” or “satisfactory to” the Contracting Officer.
The word “will” generally pertains to decisions or actions of the Contracting Officer.
Whenever in these specifications, or in other contract documents, the following terms (or pronouns in place of them) are used, the intent and meaning shall be interpreted as follows: reference to a specific standard, test, testing method, or specification shall mean the latest published edition or amendment that is in effect at the solicitation issue date for the public works contracts.
901.02 Specification Format These specifications are divided into Sections.
Sections 900 through 906, 908 and 909 consist of general contract requirements for which no direct payment is made. The requirements contained in Sections 900 through 906 are applicable to all contracts.
Sections 907, 908, 909 and 910 through 989 consist of construction contract requirements for specific items of work. Work under these Sections is paid for directly or indirectly according to Subsection 906.04 and the Section ordering the work. When there is no pay item in the bid schedule, no direct payment is made.
Sections 990 through 999 contain the material requirements for Sections 910 through 989. No direct payment is made in Sections 990 through 999. Payment for material is included as part of the work required in Sections 910 through 989.
The first three digits of the pay item number identify the Section under which the work is performed.
901.03 Abbreviations. Whenever these abbreviations are used in the specifications, they represent the following:
(a) Acronyms
AASHTO American Association Of State Highway And Transportation Officials ABS Acrylonitrile-Butadiene-Styrene
10/30/2014 Trail Specifications-5
AITC American Institute of Timber Construction ANSI American National Standards Institute AQ Actual Quantities APA American Plywood Association ASTM American Society For Testing And Material AWPA American Wood Protection Association CO Contracting Officer C.F. Cubic Feet C.Y. Cubic Yard DQ Design Quantities EA Each FAR Federal Acquisition Regulation g Grams HDPE High-Density Polyethylene hr Hour kg Kilogram kN Kilonewtons lb Pound L.F. Linear Feet LS Lump Sum LSQ Lump Sum Quantities m Meter m2 Square Meter m3 Cubic Meter mi Mile mm Millimeter MPa Megapascals MSE Mechanically Stabilized Earth N Newton NBS National Bureau Of Standards NCMA National Concrete Masonry Association OSHA Occupational Safety & Health Administration Pa Pascal PE Polyethylene PS Product Standard Issued By The U.S. Department Of Commerce psi Pounds Per Square Inch PVC Polyvinyl Chloride S.F. Square Feet SQ Staked Quantities S.Y. Square Yard WCLIB West Coast Lumber Inspection Bureau WWPA Western Wood Products Association WWPI Western Wood Preservers Institute
10/30/2014 Trail Specifications-6
Additional abbreviations may be found in Section 101.03 of the Standard Specifications for Construction of Roads and Bridges on Federal Highway Projects
(FP-24).
(b) Slope notation (vertical: horizontal). For slopes flatter than 1:1, express the slope as the ratio of one unit vertical to a number of units horizontal. For slopes steeper than 1:1, express the slope as the ratio of a number of units vertical to one unit horizontal.
901.04 Definitions The following terms, or pronouns in place of them, are used in these specifications or in other contract documents, the intent and meaning are as follows:
Barriers. A fence or other obstacle that prevents movement or access.
Base Course. The layer or layers of specified material of designed thickness placed on a trailbed to support surfacing.
Batter. A backward and upward slope of the face of a wall.
Berm. The ridge of material formed on the outer edge of the trail that projects higher than the tread.
Borrow. Suitable materials taken from approved sources designated on the plans or on the ground, to be used for embankments and backfilling.
Bridge. A trail structure, including supports, erected over a depression or obstruction such as a body of water, a road, a trail, or a railroad that provides a continuous pathway and that has a deck for carrying traffic or other loads.
Cap Rock. Rock placed in the top or uppermost layer in a constructed rock structure, such as a talus or rubble rock section or rock retaining wall.
Catch Point. The outer limits of a trailway where the excavation and/or embankment intersect with the ground line.
Clearing Limit. The area over and beside the trail that is cleared of trees, limbs, and other obstructions.
Climbing Turn. A reverse in direction of trail grade without a level landing used to change elevation on a steep slope.
Compacted. Consolidation that is obtained by tamping or rolling suitable material until no noticeable displacement of material is observed.
Contracting Officer (CO). An official of the Government with the authority to enter into, administer, and/or terminate contracts and make related determinations and findings. The term includes certain authorized representatives of the CO acting within the limits of their authority as delegated by the CO.
Culvert. Any structure with a bottom, regardless of the fill depth, the depth of invert, or the presence of a horizontal driving surface, or any bottomless (natural
10/30/2014 Trail Specifications-7 channel) structure with footings that does not have wheel loads in direct contact with the top of the structure.
Curb. A border defining the edge of the trail or trail bridge.
Cushion Material. Native or imported material generally placed over rocky section of unsurfaced trail to provide a usable and maintained traveled way.
Designated on the Ground. The location of materials, work areas, and construction items, including lines and grades, marked on the ground with stakes, flagging, tags, or paint.
Drawings. Design sheets or fabrication, erection, or construction details submitted to the Government by the Contractor according to FAR Clause 52.236-21 Specifications and Drawings for Construction. Also refers to submissions and submittals.
Duff. Organic material overlying rock or mineral soil.
Embankment. A structure of suitable material placed on the prepared ground surface and constructed to the trailbed elevation.
Excess Excavation. Material in the trailway in excess of that needed for construction of designed trailways.
Falsework. Temporary construction work on which a main work is wholly or partly built and supported until the main work is strong enough to support itself.
Ford. A water-level stream crossing constructed to provide a level surface for safe traffic passage.
Full Bench. Trailbed constructed entirely on undisturbed material.
Gabion Basket. Rectangular wire baskets filled with rock used as pervious, semiflexible building blocks for slope and foundation stabilization.
Grade. The vertical distance of ascent or descent of the trail expressed as a percentage of the horizontal distance.
Hazard Tree. An unstable tree that is likely to fall across the trail.
Header Rock. Rock laid with the narrow end towards the face of the wall.
Inslope. Where the trails tread is sloped downward toward the backslope.
Leave Tree. Trees designated to be left or to remain undisturbed after trail construction.
Mineral Soil. Soil or aggregate that is free from organic substances and contains no particles larger than 2 inches at their greatest dimension.
Outslope. Where the trail tread is sloped downward toward the embankment or daylight side of the trailway.
Plans. The contract plans furnished by the Government showing the location, type, dimensions, and details of work.
10/30/2014 Trail Specifications-8
Retainers. Embedded border of wood or rock used to retain fill and/or surface material.
Sideslope. The natural slope of the ground, usually expressed as a percentage.
Slough. That material from the backslope or the area of the backslope that has raveled onto the trailbed.
Slump. Where the trailbed material has moved downward, causing a dip in the trail grade.
Special Contract Requirements. Specifications that detail the conditions and requirements peculiar to an individual project, including additions and revisions to the standard specifications.
Standard Plans. Detailed plans approved for repetitive use and included as part of the plans.
Standard Specifications. The Standard Specifications for Construction of Trails on Federal Projects approved for general application and repetitive use.
Surfacing. Material placed on top of the trailbed or base course that provides the desired tread.
Suitable Material. Rock that can be accommodated in the trail structure, and soil free of duff with a recognizable granular texture.
Switchback. A reverse in direction of trail grade with a level landing used to change elevation on a steep slope, usually involving special treatment of the approaches, barriers, and drainages.
Trailbed. The finished surface on which base course or surfacing may be constructed. For trails without surfacing the trailbed is the tread.
Trailway. The portion of the trail within the limits of the excavation and embankment.
Tread. The surface portion of the trail upon which traffic moves.
Turnout. A short section of extra trail width to provide for passage of trail users.
Waterbar. A structure used for turning water off the trail, usually made of logs or stones.
Water Courses. Any natural or constructed channel where water naturally flows or will collect and flow during spring runoff, rainstorms, etc.
Additional definitions may be found in Section 101.03 of the Standard Specifications for Construction of Roads and Bridges on Federal Highway Projects
(FP-24).
10/30/2014 Trail Specifications-9
960. Trail Bridges Section 969 – Reserved for Trail Bridge Special Project Specifications
969.10. Prefabricated FRP Trail Bridge
969.10.01 This work consists of designing, furnishing, fabricating, and delivering a trail bridge of fiber-reinforced polymer (FRP) composite construction, including all required materials, hardware, sills, backwalls, rail systems, curbs, decking, anchorages, connections, and bearings as SHOWN ON THE PLANS. Work includes all other incidental work necessary to complete the bridge installation. These specifications are for a fully engineered clear span bridge and shall be regarded as minimum standards for design and construction.
(a) Qualified Suppliers - The bridge manufacturer shall have been in the business of design and fabrication of bridges for a minimum of 5 years and provide a list of five successful bridge projects, of similar construction, each of which has been in service for at least 3 years. List the location, bridge size, owner, and contact reference for each bridge.
Design
969.10.02 Engineering Requirements. Structural design of the bridge structure(s) shall be performed by or under the direct supervision of a licensed professional engineer and done in accordance with recognized engineering practices and principles. The engineer shall be licensed to practice in the State of Colorado. The design shall be in accordance with AASHTO LRFD Bridge Design Specifications, Current Edition and as recommended in AASHTO’s LRFD Guide Specifications for Design of Pedestrian Bridges, Current Edition. The design shall meet the following requirements unless otherwise SHOWN ON THE PLANS:
1. Pedestrian Load – Main supporting members shall be designed for a pedestrian live load of 90 psf. The pedestrian live load shall be applied to those areas of the walkway so as to produce maximum stress in the member being designed.
2. Vehicle Load – When the clear deck width between railings is greater than 7 ft and less than 10 ft the bridge shall be designed for an occasional single maintenance vehicle of 10,000 lbs (H5 Design Vehicle). When clear deck width is greater than 10 feet, the bridge shall be designed for an occasional single maintenance vehicle of 20,000 lbs (H10 Design Vehicle).
The vehicle load shall not be placed in combination with the pedestrian live load or snow load. A vehicle impact allowance is not required.
3. Other Loads– Other loads such as snow, equestrian, wind and fatigue loads and load combinations shall be designed for as specified in AASHTO LRFD and as SHOWN ON THE PLANS. When a snow load greater than the 90 psf pedestrian load is SHOWN ON THE PLANS the bridge shall be analyzed and designed for the controlling load. Sustained snow load
10/30/2014 Trail Specifications-10 conditions shall be evaluated for time dependent effects (creep and relaxation) and expected recovery behavior.
4. Deflection – Pedestrian live load deflection shall not exceed L/360 for FRP as SHOWN ON THE PLANS.
Vertical frequency (fn): = 5.0 Hz
The fundamental frequency of the pedestrian bridge (in the vertical direction) without live load should be greater than 5.0 Hz to avoid any issues with the first and second harmonics.
Horizontal frequency (fn): = 3.0 Hz
The fundamental frequency of the pedestrian bridge (in the horizontal direction) without live load should be greater than 3.0 hertz (Hz) to avoid any issues due to side-to-side motion involving the first and second harmonics.
5. Vibration – The fundamental frequency of the pedestrian bridge without live load shall be greater than 3.0 hertz in the vertical direction and 1.3 hertz in the lateral direction. The minimum fundamental frequency for loads other than pedestrian loads, such as equestrian and mule trains, shall be determined by the design engineer.
6. Camber - The bridge shall have a vertical camber dimension at midspan equal to 100% of the full dead load deflection plus 1% of the full length of the bridge or as SHOWN ON THE PLANS. Bridges can be precambered to eliminate initial dead load deflections.
969.10.03 General Features of Design. The following are the required minimum design features unless otherwise SHOWN ON THE PLANS. All members shall be fabricated from pultruded FRP composite profiles and structural shapes as required.
1. Span -The required bridge span shall be as SHOWN ON THE PLANS.
2. Deck Width -The required bridge width between railing elements as
SHOWN ON THE PLANS.
3. Truss Type - Bridge(s) shall be designed as a FRP Composite Truss Span, a half-through truss with one (1) diagonal per panel and square end vertical members as SHOWN ON THE PLANS.
4. Half-through truss bridges will be designed utilizing underhung floor beams as SHOWN ON THE PLANS.
5. The top of the top chord shall not be less than 42 inches above the deck (measured from the high point of the riding surface) unless otherwise
SHOWN ON THE PLANS.
6. Railings
10/30/2014 Trail Specifications-11
a) Safety Rails - Horizontal safety rails shall be placed on the structure to prevent a 4-inch sphere from passing through the truss or as SHOWN ON THE PLANS. The safety rail system shall be designed for 50 pounds per linear foot transversely and vertically, acting simultaneously on each rail. Continuous horizontal midrails shall be located on the inside of the trusses. Maximum opening between the midrails shall be available as required but should not be greater than 9". If preferred, vertical pickets can be provided upon request.
b) Railings shall be a minimum of 54" above the floor deck.
c) Toeplates (Optional) Park and trail bridge toeplates (if required) are 3" green channels. Industrial catwalks use standard 4" yellow toeplate shapes unless otherwise specified.
969.10.04 Design Drawings and Calculations. Provide design drawings and calculations for the prefabricated bridge including wind, seismic and bearing forces. The Contractor is responsible for preparing all shop drawings necessary for erection of the bridge. All design drawings and calculations shall have the signature and seal of a registered professional engineer.
The Contractor shall submit all design drawings and calculations in accordance with section 903 at least 30 days in advance of the start of fabrication to allow time for review by the CO and correction of any changes. Include plan, elevation, and section views of the pedestrian bridge superstructure, dimensions of all components, connection details, and general and specific notes regarding design and construction.
The Contractor and COR shall be provided with detailed installation instructions.
Materials
969.10.05 Materials.
FRP bridges shall be fabricated from high-strength E-glass and isophthalic polyester resin unless otherwise specified. Weathering and ultraviolet light protection shall be provided by addition of a veil to the laminate construction.
Furnish materials that meet the following requirements:
1. Hardware – All fasteners and hardware shall follow FP-24, Section 717 and as SHOWN ON THE PLANS. Bolted connections shall be A307 hot-dipped galvanized steel unless otherwise specified. Mounting devices shall be galvanized or stainless steel.
2. Decking - Wood decking shall be West Coast Regional Douglas Fir or No. 2 Southern Pine treated according to the American Wood Preservers Bureau or as SHOWN ON THE PLANS. Treated wood shall meet the requirements as SHOWN ON THE PLANS. 3- by 8-in planks are SHOWN ON THE PLANS for pedestrian and bicycle type loading conditions.
10/30/2014 Trail Specifications-12
Standard 3- by 12-in planks can be provided for equestrian and light vehicle type loading conditions as required. High-strength, E-glass/isophthalic polyester resin planks or recycled plastic deck planks can also be provided as required.
Minimum material strengths and properties are as follows:
Tension: 33,000 psi Compression: 33,000 psi Shear: 4,500 psi Bending: 33,000 psi Modulus: 2,800,000 psi Young's Modulus: 2,800,000 psi
The minimum thickness of FRP Composite shapes shall be as follows unless otherwise specified: Square-tube members (closed-type shape) shall be 0.25 in.
Wide-flange beams, channel sections, and angles (open-type shapes) shall be a minimum thickness of 0.375 in. Standard plate shall be a minimum thickness of
0.375 in.
969.10.06 Allowable Stress Design Approach
An Allowable Stress Design (ASD) approach may only be used in addition to Load and Resistance Factor Design (LRFD) for the design of all structural members.
Factors of safety in the design of FRP bridges are as follows unless otherwise specified (based on the Ultimate Strength of the FRP material):
Tension: 2.5 Bending: 2.5 Compression: 2.5 End bearing: 2.5 Shear: 2.5 Connections: 3.0
969.10.07 Submittals
1. Submittal Drawings - Schematic drawings and diagrams shall be submitted to the client for their review after receipt of order. As required, all drawings shall be signed and sealed by a licensed professional engineer.
2. Submittal Calculations - As required, structural calculations shall be submitted to the client. All calculations will be signed and sealed by a licensed professional engineer.
3. FRP Certification - All certified test reports shall be furnished upon request. Test reports shall show the chemical analysis and physical test results for each composition of FRP used in the work. All FRP shall be produced in the United States of America.
10/30/2014 Trail Specifications-13
4. Bolt Certification - All certified mill test reports shall be furnished upon request. Mill test reports shall show the chemical analysis and physical test results for each heat of steel used in the work. All bolts shall be produced in the United States of America.
5. Wood Certifications - Furnish the following compliance certificates to the CO upon delivery of the wood materials to the jobsite:
(a) Verification of compliance with grading rules and species of timber and lumber. Provide certification by an agency accepted as competent by the American Lumber Standards Committee (ALSC).
(b) Lot certification of each charge for preservative, penetration in inches, and retention in pounds per cubic foot (assay method) by a qualified independent inspection and testing agency. In addition, have the producer of the treated products provide written certification that Best Management Practices (BMP's) in accordance with "Best Management Practices for Treated Wood in Western Aquatic Environments," published by the Western Wood Preservers Institute (WWPI) and Canadian Institute of Treated Wood, were followed, including a description and appropriate documentation of the applicable BMP's used.
(c) Such other certifications as SHOWN ON THE PLANS or called for in the SPECIAL PROJECT SPECIFICATIONS.
Provide shop drawings in accordance with section 903 for all bridges 30 days in advance of fabrication when SHOWN ON THE PLANS or in the SPECIAL PROJECT SPECIFICATIONS. Show all dimensions and fabrication details for all cut, framed, or bored timbers.
Fabrication
969.10.08 General Fabricate a prefabricated FRP trail bridge as required under construction section 969.00. and as SHOWN ON THE PLANS.
969.10.09 Tolerances All cutting and drilling fabrication to be done by experienced fiberglass workers using carbide or diamond-tipped tooling to a tolerance of 1/16".
No material deviations beyond industry standards are accepted. All cut edges to be cleaned and sealed.
969.10.10 Performance. Provide 14-day notice prior to delivery of prefabricated bridge. If the prefabricated superstructure is not installed immediately upon delivery to the project site, provide appropriate equipment and labor to unload and stack, support, and store all material at the delivery point designated by the COR.
Support and stack all components to prevent damage. Furnish and install blocking such that all components are supported at least 8 inches above the ground.
Finishing
10/30/2014 Trail Specifications-14
969.10.11 Bridge color shall be determined by Forest Service with green and brown as standard. No painting is required as the color is added during the manufacturing process. Custom colors can be provided upon request.
Delivery and Erection
969.10.12 Delivery is made by truck to a location nearest the site accessible by roads. Supplier will notify the client in advance of the expected time of arrival at the site. Bridges are usually shipped to the site in component parts or partially assembled depending on site requirements. The spans can then be completely assembled using standard hand tools. Splicing (if required) and placement of the bridge will be the responsibility of the client.
969.10.13 Erection Direction. For bridges shipped in component parts or partially assembled, Supplier shall provide assembly drawings and a recommended assembly procedure for building the bridge. Temporary support or rigging equipment, if needed, is the responsibility of the client. For bridges shipped assembled, Supplier shall advise the client of the actual lifting weights, attachment points and all necessary information to install the bridge.
Warranty
969.10.14 Supplier shall warrant the structural integrity of all FRP materials, design and workmanship for 15 years. This warranty shall not cover defects in the bridge caused by foundation failures, abuse, misuse, overloading, accident, faulty construction or alteration, or other cause not the result of defective materials or workmanship. This warranty shall be limited to the repair or replacement of structural defects and shall not include liability for consequential or incidental damages.
Measurement
969.10.15 Measure the section 969 items listed in the bid schedule according to section 906.
Payment
969.10.16 The accepted quantities will be paid at the contract price per unit of measurement for the Section 969 pay items listed in the bid schedule. Payment will be full compensation for the work prescribed in this Section. See Subsection 906.04.
10/30/2014 Trail Specifications-15
990. Materials Section 990 - Materials
990.01 General. Materials specification not found in this section will be covered by the most current version of Standard Specifications for Construction of Roads and Bridges on Federal Highway Projects, U.S. Department of Transportation, Federal Highway Administration.
Section 991 - Rock, Grid Pavement Units, Aggregate and Asphalt
991.01 Rock. Use sound, durable rock free of rifts, seams, laminations, and minerals that could deteriorate as a result of weathering. Dress rock to remove thin or weak portions before use.
Furnish rock of the size, shape, weight, and face area necessary to produce the general characteristics and appearance SHOWN ON THE PLANS.
991.02 Gabion and Revet Mattress Rock. Ensure that rock conforms to the requirements of Section 991.01 and the following specifications.
(a) Coarse durability index, AASHTO T 210 52 min.
(b) Unit weight of a filled basket 100 pounds per cubic foot min.
(c) Gradation:
(1) Baskets 12 inches or greater in the vertical dimension:
Maximum dimension of rock .................…. 8 inch Minimum dimension of rock ...................... 4 inch
(d) (2) Baskets less than 12 inches in the vertical dimension:
Maximum dimension of rock ..................... 6 inch Minimum dimension of rock ..................... 3 inch
991.03 Grid Pavement Units. Use concrete grid pavement units with a minimum compressive strength of 4495 lbs/in2 that meet the National Concrete Masonry Association (NCMA) Designation: A-15-82: Specifications for Grid Pavers.
991.04 Pit-Run Aggregate. Use pit-run aggregates consisting of native materials that can be placed on the trail without crushing or screening. No gradation, other than a maximum size, will be required. Provide pit-run aggregate with a maximum size as
SHOWN IN THE SCHEDULE OF ITEMS.
991.05 Screened Aggregate. Use screened material consisting of gravel, talus, rock, sand, shale, or other suitable material that is reasonably hard, durable, and free of organic material, mica, clay lumps, or other deleterious material. Use screened aggregate meeting the gradation requirements shown in table 961-1 and of the grading SHOWN IN THE SCHEDULE OF ITEMS.
10/30/2014 Trail Specifications-16
991.06 Crushed Aggregate for Base or Surface Course. Use crushed aggregate meeting the requirements of tables 991-1 and 991-2 and SHOWN IN THE
SCHEDULE OF ITEMS.
At least 50 percent, by weight, of the aggregate retained on the No.4 sieve is to have one fractured face. Naturally fractured faces may be included in the 50-percent requirement.
The CO may approve other gradations if they are similar to those specified Grade aggregate from coarse to fine within the gradation band.
Table 991-1-Crushed and screened aggregate grading requirements for base or surface courses.
Percent Passing (AASHTO T 11 and T 27)
Sieve Grading A Grading B Grading C Grading D
1" ¾" 100 100 ½" 50-90 70-100 3/8" 100 100 No.4 30-65 45-75 60-85 70-90 No.8 25-55 30-60 35-70 45-70 No.30 15-40 20-40 No.200 6-12 6-20 5-20 5-20
Table 991-2.-Crushed Aggregate Quality Requirements Description AASHTO Test Method Requirement
Percent Wear T 96 40 Max.
Durability Index, Coarse and Fine T 211 35 Min.
Liquid Limit T 89 35 Max.
Plasticity Index T 91 2-11
991.07 – Asphalt. Asphalt material for trail construction shall conform to requirements of the U.S. Department of Transportation, Federal Highway Administration, Standard Specifications for Construction or Roads and Bridges on Federal Highway Projects, most current edition, Section 702 – Asphalt Material.
10/30/2014 Trail Specifications-17
991.08 – Cement. Cement material for trail construction shall conform to requirements of the U.S. Department of Transportation, Federal Highway Administration, Standard Specifications for Construction or Roads and Bridges on Federal Highway Projects, most current edition, Section 701 – Cement.
Section 992 – Pipe Material
992.01 General. Use pipe, coupling bands, and special sections such as elbows, tees, and wyes made of the same material and of the same thickness as the conduit to which they are joined, unless otherwise specified.
992.02 Corrugated Steel Pipe, Pipe Arches and Underdrains
(a) Riveted Pipe and Pipe Arches. Use pipes meeting the requirements of
AASHTO M 36.
(b) Welded Pipe and Pipe Arches. Use corrugated metal pipe and pipe arches fabricated by resistance spot welding meeting the applicable requirements of AASHTO M 36.
(c) Helical Pipe. Use un-perforated helically corrugated pipe with continuous lock or welded seams meeting the applicable requirements of
AASHTO M 36.
(d) Coupling Bands. Use coupling bands meeting the requirements of
AASHTO M 36.
(e) Special Sections. Use special sections such as elbows, tees, and wyes meeting the same thickness as the conduit to which they are joined and meeting the applicable requirements of AASHTO M 36.
(f) Flared-End Sections. Use flared-end sections for inlet and outlet ends of pipe and pipe arch culverts meeting the applicable requirements of
AASHTO M 36.
(g) Corrugated Steel Pipe for Underdrains. Use perforated galvanized pipe meeting the requirements of AASHTO M 36. Use polymer-precoated perforated underdrains meeting the requirements of AASHTO M 245
992.03 Corrugated Aluminum Alloy Culvert Pipe, Pipe Arches, and Underdrains. Use pipe meeting the requirements of AASHTO M 196.
992.05 Aluminum-Coated (Aluminized Type 2). Use pipe and coupling bands meeting the requirements of AASHTO M 36 except that they must be made from material meeting the requirements of AASHTO M 274.
992.06 Concrete Pipe and Pipe Arches
(a) Non-Reinforced Concrete Pipe. Conform to AASHTO M 86M for the diameters and strength classes specified.
10/30/2014 Trail Specifications-18
(b) Reinforced Concrete Pipe. Conform to AASHTO M 170M for the diameters and strength classes specified. For precast reinforced concrete end sections, conform to cited specifications to the extent they apply.
(c) Perforated Concrete Pipe. Conform to AASHTO M 175M type 1 or 2 and AASHTO M 86M for the diameters and strength classes specified.
(d) Reinforced Arch-Shaped Concrete Pipe. Conform to AASHTO M 206M for the diameters and strength classes specified.
(e) Reinforced Elliptically-Shaped Concrete Pipe. Conform to AASHTO M 207M for the diameters, placement design (horizontal or vertical), and strength classes specified.
992.07 Precast Reinforced Concrete Box Sections. Conform to AASHTO M 259M or M 273M, as applicable, for dimensions and loading conditions specified.
992.08 Plastic Pipe. Furnish perforated and non-perforated plastic pipe conforming to the following for the sizes and types specified. For watertight joints, conform to
ASTM D 3212.
(a) Smooth wall polyethylene pipe. Furnish 12 to 42-inch diameter pipe conforming to ASTM F 714 and minimum cell class, ASTM D 3350, 335434C.
(b) Corrugated polyethylene pipe. Furnish 12 to 42-inch diameter pipe conforming to AASHTO M 294M. For sanitary sewer applications, furnish AASHTO M 294M type S pipe with watertight joints.
(c) Profile wall (ribbed) polyethylene pipe. Furnish 18 to 48-inch diameter pipe conforming to ASTM F 894 and minimum cell class, ASTM D 3350, 334433C or 335434C.
(d) Corrugated polyethylene drainage tubing. Furnish 3 to 10-inch diameter tubing conforming to AASHTO M 252M.
(e) Smooth wall polyvinyl chloride pipe. Furnish 4 to 15-inch diameter pipe conforming to AASHTO M 278 and minimum cell class, ASTM D 1784, 12454B or 12364C. For sanitary sewer applications, conform to
ASTM D 3034.
(f) Profile wall (ribbed) polyvinyl chloride pipe. Furnish 4 to 48-inch diameter pipe conforming to AASHTO M 304M and minimum cell class, ASTM D 1784, 12454C or 12364C. For sanitary sewer applications, conform to ASTM F 794 or F 949.
(g) Acrylonitrile-butadiene-styrene (ABS) pipe. Conform to AASHTO M
264. For perforations, conform to AASHTO M 278.
10/30/2014 Trail Specifications-19
Section 993 - Fence Material
993.01 Barbed Wire. Furnish galvanized wire conforming to AASHTO M 280 or aluminum coated wire conforming to AASHTO M 305 type I.
993.02 Woven Wire. Furnish galvanized fabric conforming to AASHTO M 279 or aluminum coated fabric conforming to ASTM A 584.
993.04 Fence Posts.
(a) Wood. Conform to AASHTO M 168 and as SHOWN ON THE PLANS.
Peel all bark, except for red cedar posts and bracing which do not require peeling. Trim all knots flush with the surface and season the wood.
For dimension lumber for fences or gates, use timber that is sound, straight, and reasonably free from knots, splits, and shakes. Provide S4S finish.
(b) Concrete. Conform to FP-24, Section 601.
(c) Steel. For line fence posts, conform to AASHTO M 281.
993.05 Fence Gates. Furnish wood gates conforming to conforming to AASHTO M 168 and as SHOWN ON THE PLANS. For dimension lumber for gates, use timber that is sound, straight, and reasonably free from knots, splits, and shakes. Provide S4S finish.
993.06 Metal Beam Rail. Conform to AASHTO-AGC-ARTBA A Guide to Standardized Highway Barrier Hardware.
(a) Galvanized steel rail. Furnish W-beam or thrie beam rail elements fabricated from corrugated sheet steel conforming to AASHTO M 180 for the designated shape, class, type, and mass of coating specified.
(b) Corrosion resistant steel rail. Furnish W-beam or thrie beam rail elements and associated weathering steel hardware conforming to the following:
(1) Shapes and plates ASTM A 242
(2) Rail elements AASHTO M 180
(3) Fasteners AASHTO M 180
993.07 Guardrail Posts. Conform to AASHTO-AGC-ARTBA “A Guide to Standardized Highway Barrier Hardware.”
Do not use a wood guardrail post that has a thorough check, shake, or end slit in the same plane as, or a plane parallel to the bolt hole and extending from the top of the post to within 3 inches or the bolt hole.
For steel-backed timber rail posts, furnish 10 by 12-inch posts conforming to Subsection 710.08.
993.08 Guardrail Hardware. Conform to the AASHTO-AGC-ARTBA A Guide to Standardized Highway Barrier Hardware.
10/30/2014 Trail Specifications-20
For angles, channels, wide flanges, and plates not contained in the above standard, conform to ASTM A 36M. For structural tubing for short steel posts, conform to ASTM A 500 or ASTM A 513 grade 1008. Galvanize soil plates and structural tubing according to AASHTO M 111. Do not punch, drill, cut, or weld the metal after galvanizing.
993.09 Temporary Plastic Fence. Furnish plastic noncorrosive fence fabricated from polyethylene (HDPE) and UV stabilized for outdoor weathering. Conform to the following:
(a) Height 48 inch min.
(b) Mesh openings 3 to 3.5 inches
(c) Color International orange
(d) Mass 0.168 lb/ft min.
10/30/2014 Trail Specifications-21
Section 994 - Geosynthetics
994.01 Geotextiles
(a) Use geotextiles, alone or in combination with other geosynthetics that meet the following Class B requirements for subsurface drainage as specified in
AASHTO M288.
(1) Grab Strength at 50 percent elongation ASTM D4632-91 ................…….. 355 N min.
(2) Seam Strength, ASTM D 4632 ....................……... 310 N min.
(3) Puncture Strength, ASTM D4833-88 ................…….. 110 N min.
(4) Mullen Burst, ASTM D 3786-87 ......................... 900 kPa min.
(5) Trap Tear Strength, ASTM D4533-91 ................…….. 110 N min.
(b) Use geotextile meeting the following critical physical properties, unless otherwise SHOWN ON THE PLANS.
(1) Material Structure ................…….. Nonwoven (all purposes) or Slit Film (for reinforcement or separation)
(2) Polymer Composition ..........……. Polypropylene
(3) Apparent Opening, ASTM D 4751-87 ........…………. .30 mm max.
(4) Permittivity, ASTM D4491-92 .............................…….. 4060 liters/minute/m2 min.
(5) Ultraviolet Degradation .......…….. 70 at150 hours
994.02 Geonet. Use geonet meeting the following critical physical proper-ties unless otherwise SHOWN ON THE PLANS.
(a) Polymer Composition of Core (Net or Mesh)............................…….. Medium PE or HDPE
(b) Permeability……………………….... 0.001cm/second min.
(c) Geotextile ......…………..………..…. Must meet all Section
994.01 requirements
(d) Compressive Strength of Core, ASTM D1621......…………. 500 kPa min.
(e) Transmissivity with Gradient at 0.1, Pressure at 10 kPa.....……....... 0.0009 m2/second min.
10/30/2014 Trail Specifications-22
994.03 Geogrids. Use geogrids made from polypropylene or coated polyester that meets the following critical physical properties.
(a) Polymer Type ..............................……… HDPE, Polypropylene, or Polyester with Acrylic or PVC coating
(b) Mass per Unit Area, ASTM D5261-92... 175 g/m2 min.
(c) Maximum Aperture Size
(1) Direction (MD) ....………………… 100 mm
(2) Cross-Direction (XD) ..........……… 75 mm
(d) Wide-Width Strip Tensile Strength at 5 percent Strain, ASTM D4595-86
(1) Machine Direction (MD) ....……… 8 kN/m min.
(2) Cross-Direction (XD) .........……… 6 kN/m max.
994.04 Geocells. Use geocells meeting the following physical properties.
(a) Composition ...............................……. PE or HDPE
(b) Geocell Weight expanded: ............….. 1.70 kg/m2 min.
(c) Minimum Cell Seam Peel Strength, U.S. Army Corps of Engineers Technical Report G:-86-19, Appendix A .................................…… 800 N min.
(d) Expanded Dimensional Properties…... AS SHOWN ON PLANS
994.05 Sheet Drains. Use sheet drains meeting the following critical physical properties.
(a) Core Polymer Composition ....……… Polystyrene, HDPE, or polypropylene attached
(b) Geotextile ............................………… Nonwoven on one side if core solid;
on both sides if core perforated.
Must meet all Section 994.01 requirements
(c) Core Thickness, ASTM D5199 .…… 10 mm min.
(d) Core Compressive Strength at Yield, ASTM D1621 .................…… 650 kPa max.
994.06 Fasteners. Use anchors or fasteners of the design recommended by the manufacturer, and install per manufacturer's specifications.
994.07 Certification. Furnish a certificate or affidavit signed by an official from the company manufacturing the geosynthetic, verifying that the geosynthetic meets specifications.
994.08 Delivery, Storage, and Handling. During shipment and storage, wrap all geosynthetics to protect them from sunlight. When storing geosynthetics, protect them from mud, soil, dust, and debris. If materials are not installed immediately after delivery to site, do not store them in direct sunlight.
10/30/2014 Trail Specifications-23
Section 995 - Material for Timber Structures
995.01 Untreated Structural Timber and Lumber. Conform to AASHTO M 168.
Furnish an inspection certification from an agency accredited by the American Lumber Standards Committee for the species and grade. Mark all pieces with the inspection service, grade designation, species, and inspector identity.
Season and dry all structural timber and lumber before fabrication. Do not use material that is twisted, curved, or otherwise distorted.
Do not use boxed-heart pieces of Douglas fir or redwood in outside stringers, floor beams, caps, posts, sills, or rail posts. Boxed-heart pieces are defined as timber so sawed that at any point in the length of a sawed piece the pith lies entirely inside the four faces.
Select native log stringers from designated sites on Government-administered land.
Select the species and sizes of materials as SHOWN ON THE PLANS. Select native log stringers that are straight, sound, and free of defects. Obtain CO approval of logs and trees before felling or moving them to the site. Fell trees to prevent damage to standing timber and to minimize breakage of trees to be used. Buck logs from felled trees in such a way to minimize waste and to obtain the required length and diameter.
Peel logs, square the ends, and trim the knots and limbs flush unless otherwise SHOWN ON THE PLANS. Scatter the debris from the processing of timber away from the trail and so it will not block the trail or plug water courses.
Field treat the following untreated timber surfaces in accordance with AWPA standard M4.
(a) All ends and tops, and all contact surfaces of posts, sills, and caps.
(b) All ends, joints, and contact surfaces of bracing and truss members.
(c) All surfaces of timber bumpers and the back faces of bulkheads.
(d) All other timber that will be in contact with earth.
(e) All ends of log stringers.
995.02 Holes for Bolts, Dowels, Rods & Lag Screws. Bore all holes before preservative treating the wood.
Bore holes for round drift bolts and dowels 1/16 inch smaller in diameter than that of the bolt or dowel to be used. Ensure that the diameter of holes for square drift bolts or dowels is equal to the side dimension of the bolt or dowel.
Bore holes for machine bolts 1/16 inch larger than the diameter, except when galvanized bolts are specified. In this case, drill all holes 1/8 inch greater than the bolt size.
10/30/2014 Trail Specifications-24
Bore holes for lag screws 1/16 inch larger for the shank portion of the lag screw and drill the remainder of the hole approximately 75 percent of the shank diameter to a depth of 1 inch less than the length of the screw.
995.03 Hardware. Use nails of standard form (ASTM F 1667), wood screws (ANSI/ASME B 18.6.1), hex headed bolts and nuts (ASTM A307), lag screws (ASTM A307 and ANSI/ASME B18.2.1), carriage bolts (ASTM A307), and drift pins and dowels (ASTM A307) as SHOWN ON THE PLANS.
Fabricate washers from gray iron or malleable iron castings unless structural washers are specified. Use malleable iron washers with a diameter approximately four times the bolt diameter under all bolt heads or nuts in contact with wood, unless otherwise SHOWN ON THE PLANS.
Galvanize all hardware according to AASHTO M 232 or cadmium plate all hardware according to ASTM B 766 class 12, type III, unless otherwise SHOWN ON THE PLANS, except for the glued laminated deck panel dowels. Ensure that all fasteners, including nails, spikes, bolts, washers, and timber connectors, other than malleable iron, are galvanized.
Final tighten all nuts to provide proper bearing and snug tight condition. Snug tight is defined as sufficient tightness to bring faces of members into firm contact with each other. Cut off excess bolt lengths of more than 1 inch. After final tightening, check or burr all bolts effectively with a pointing tool to prevent loosening of the nuts.
995.04 Treated Structural Timber and Lumber. Furnish wood according to Subsection 995.01. Incise all wood and make all dimensional cuts and holes in the wood before pressure treatment. Use wood preservative treatment methods meeting the requirements of AASHTO M 133 as SHOWN ON THE PLANS.
Treat dimensional lumber, sawn timber and glued laminated timber members according to AWPA Standards as SHOWN ON THE PLANS.
All treated stringers, decking, running planks, and handrails shall be treated after fabrication in accordance with AWPA U1, Use Category System, using Pentachlorophenol or Copper Naphthenate (CuN) in Light Oil, (Type C Solvent) for Use Category UC3B.
All treated substructures (sills, backing planks, cribs, timber walls, etc.) shall be treated after fabrication in accordance with AWPA U1 Use Category System, using Pentachlorophenol or Copper Naphthenate (CuN) in Heavy Oil (Type A Solvent) for Use Category UC4B.
Treat timber members shall comply with the requirements of the current edition of WWPI’s Best Management Practices for the Use of Treated Wood in Aquatic Environments.
Except for pine, incise before treatment all surfaces greater than 2 inches in width and all Douglas fir and western larch surfaces. Field treat all cuts, abrasions, drilled
10/30/2014 Trail Specifications-25 holes, and recesses that occur after initial preservative treatment in accordance with the requirements specified in AWPA standard M4, Standard for the Care of Pressure-Treated Wood Products. Plug all unused holes with preservative-treated plugs. Perform all field-applied preservation treatment with necessary precautions so as to prevent soil and/or water contamination.
All treated timber members must have an approved American Lumber Standards Committee quality mark, individually or sealed pallets, assuring that treatment conforms to the appropriate AWPA standards.
Submit a certified copy of the lot certification, by a qualified independent inspection and testing agency, to the CO for each charge of preservative, stating penetration in inches and retention in pounds per cubic foot (assay method). In addition, provide a written certification from the producer of the treated products that "Best Management Practices for Treated Wood in Western Aquatic Environments," published by the Western Wood Preservers Institute and Canadian Institute of Treated Wood, were utilized. Include a description and appropriate documentation of the Best Management Practices used.
Handle treated timber according to the Consumer Information Sheet published by AWPA. Do not cut, frame, or bore treated timber after treatment unless approved by the CO. Handle treated timbers carefully and do not drop, damage outer fibers, or penetrate the surface with tools. Do not use cant dogs, hooks or pike poles. In coastal waters, do not cut or bore timber below the highwater mark.
995.05 Structural Glued Laminated Timber. Furnish structural glued laminated timber according to American National Standard, "Standard Specifications for Structural Glued Laminated Timber of Softwood Species" (ANSI 117). Fabricate according to the combination and grade as indicated in the contract. Fabricate structural glued laminated members according to American National Standard, "Standard for Wood Products - Structural Glued Laminated Timber" (ANSI A190.1).
Manufacture members as industrial appearance grade for wet use conditions, using a phenol-resorcinol resin type of adhesive throughout. Use only single- or multiple-piece laminations with bonded edge joints.
10/30/2014 Trail Specifications-26
Section 996 - Gabion and Revet Mattress Material.
996.01 Basket Mesh. Twist or weld the mesh from galvanized steel wire conforming to ASTM A 641, class 3 or aluminized steel wire conforming to ASTM A 809. Use wire with a minimum tensile strength of 60,000 pounds per square inch when tested according to AASHTO T 244. The galvanized or aluminized coating may be applied after mesh fabrication. Make the mesh openings with a maximum dimension less than 4½ inches, an area less than 10 square inches, and a size less than the gabion or revet mattress rock to be used with the mesh.
(a) Gabion baskets (1 foot or greater in the vertical dimension).
Fabricate the mesh for galvanized or aluminized coated baskets from nominal-sized 0.12-inch or greater diameter wire and fabricate the mesh for polyvinyl chloride coated baskets from nominal-sized 0.11-inch or greater diameter wire.
(1) Twisted wire mesh. Form the mesh in a uniform hexagonal pattern with non-raveling double twists. For galvanized or aluminized coated baskets, tie the perimeter edges of the mesh for each panel to a 0.15-inch or greater diameter selvedge wire. For polyvinyl chloride coated baskets, tie the perimeter edges of the mesh for each panel to a 0.13-inch or greater diameter selvedge wire. Make the selvedge at least the same strength as the body of the mesh. Furnish selvedge wire from the same type of material used for the wire mesh.
(2) Welded wire mesh. For galvanized or aluminized coated baskets, weld each connection to obtain minimum average weld shear strength of 585 pounds with no value less than 450 pounds. For polyvinyl chloride coated baskets, weld each connection to obtain minimum average weld shear strength of 472 pounds with no value less than 360 pounds.
Fabricate gabion baskets in the dimensions required with a dimension tolerance of ±5 percent. Where the length of the basket exceeds 1.5 times its width, equally divide the basket into cells less than or equal to the basket width using diaphragms of the same type and size mesh as the basket panels. Prefabricate each basket with the necessary panels and diaphragms secured so they rotate into place.
(b) Revet mattresses (less than 1 foot in the vertical dimension).
Fabricate the mesh from nominal-sized 0.086-inch or greater diameter wire.
(1) Twisted wire mesh. Form the mesh in a uniform hexagonal pattern with non-raveling double twists.
This is the start of the file's text. The full file is on GovTribe.