12405B23R0019 - Amendment 05--Drawings -Clarification of Specs for Pipe size and Well System Integration.pdf
PDF 143 KB Posted
- Solicitation number
- 12405B23R0019
About this file
This document contains details for a federal solicitation requesting proposals for construction services. The USDA Agricultural Research Service Southeast Area Southeastern Fruit and Tree Nut Research Unit in Byron, Georgia is seeking to completely replace its existing irrigation system, including drilling a third water well and upgrading the associated electrical system. Contractors are to furnish all labor, materials, and supplies to perform the work outlined in the statement of work, which includes installing a new 2-inch manifold system connected to upgraded 3-inch water mains to irrigate pecan and peach orchards. The solicitation number is 12405B23R0019 and is issued as a request for quotation with a closing date TBD. The NAICS code is 221310 and size standard is $41 million. Interested parties should reference Section L.7(b) for site visit information and register in the System for Award Management prior to submitting a proposal.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R
EV
IS
IO
N
S EMICC
OF 21Q232962OL1
USDA WELL LAYOUT
AutoCAD SHX Text 4' x 4' PAD FOR ANTENNA TOWER OR POLE 65' ABOVE GROUND
AutoCAD SHX Text
GROUND RODS 10' OUT AND 10' DOWN
AutoCAD SHX Text
GROUND RODS 10' OUT AND 10' DOWN
AutoCAD SHX Text
GROUND RODS 10' OUT AND 10' DOWN
AutoCAD SHX Text
POWER POLE
AutoCAD SHX Text
POWER PANEL
AutoCAD SHX Text
PUMP PANEL
AutoCAD SHX Text
SIDE VIEW
AutoCAD SHX Text
CONTROL PANEL
AutoCAD SHX Text
FIRST USED
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
REV
AutoCAD SHX Text
CKD BY
AutoCAD SHX Text
DRWN BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text Electric Machinery Industrial Controls Corporation Perry, Ga.
AutoCAD SHX Text
24 X 36 PRINTABLE TO 11 X 17
AutoCAD SHX Text
FIRST ISSUE J.B.H. 7-25-237-25-23
AutoCAD SHX Text
B.HADDOCK
AutoCAD SHX Text 7-25-23
AutoCAD SHX Text
NOT DRAWN TO SCALE
R
EV
IS
IO
N
S EMICC
OF 21Q232962OL1
USDA WELL LAYOUT
AutoCAD SHX Text
GROUND LEVEL
AutoCAD SHX Text
WATER LINE
AutoCAD SHX Text
PUMP PANEL
AutoCAD SHX Text
CONTROL PANEL
AutoCAD SHX Text
PRESSURE SENSOR
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
DETAIL "A"
AutoCAD SHX Text
SEE DETAIL "A"
AutoCAD SHX Text
EXTERIOR WALL
AutoCAD SHX Text
PRESSURE SENSOR
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
GROUND LEVEL
AutoCAD SHX Text
WATER LINE
AutoCAD SHX Text
TO SCADA
AutoCAD SHX Text
FIRST USED
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
REV
AutoCAD SHX Text
CKD BY
AutoCAD SHX Text
DRWN BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text Electric Machinery Industrial Controls Corporation Perry, Ga.
AutoCAD SHX Text
24 X 36 PRINTABLE TO 11 X 17
AutoCAD SHX Text
FIRST ISSUE J.B.H. 7-25-237-25-23
AutoCAD SHX Text
B.HADDOCK
AutoCAD SHX Text 7-25-23
AutoCAD SHX Text
NOT DRAWN TO SCALE
AutoCAD SHX Text
WELL 3
AutoCAD SHX Text
BUILDING
| Sheets and Views |
| Q232962OL1-1-Sheet 1 |
| Q232962OL1-1-Sheet 2 |
File details come from the government source that posted it. Updated .