DESCRIPTION HAZARD PERMITTING REQUIREMENT LOCATION REMARKS
MAIN WATER MANHOLE Electrical Hazards, Potential for insufficient Oxygen, slip PERMIT REQUIRED PUMP HOUSE
FIRE WATER MANHOLE Electrical Hazards, Potential for insufficient Oxygen, slip PERMIT REQUIRED PUMP HOUSE
MAIN WATER BACKFLOW PIT Electrical Hazards, Potential for insufficient Oxygen, slip PERMIT REQUIRED PUMP HOUSE
VALVE PIT MAIN WATER Electrical Hazards, Potential for insufficient Oxygen, slip PERMIT REQUIRED VALVE PIT MAIN WATER- IN DRIVEWAY REAR
ACID PIT Electrical Hazardds, Potential for insufficient oxygen, caustics PERMIT REQUIRED COURTYARD
PUMP PIT (ACID) Electrical Hazards, Potential for insufficient oxygen, caustics PERMIT REQUIRED PUMP PIT (ACID), COURTYARD
CONDENSATE PIT - CHEM WING 0128 slip, electrical , water NON-PERMIT MECHANICAL ROOM 0128 - CHEM WING SEE NOTE 4
CONDENSATE PIT - PILOT PLANT slip, electrical , water NON-PERMIT BACK OF PILOT PLANT BY ROLL UP DOOR SEE NOTE 4
CONDENSATE PIT - ADMIN slip, electrical , water NON-PERMIT MECHANICAL ROOM 0017 SEE NOTE 4
CONDENSATE PIT - MSB slip, electrical , water NON-PERMIT ROOM 114 - MECHANICAL SERVICE BUILDING SEE NOTE 4
CONDENSATE PIT - MPL slip, electrical , water NON-PERMIT MPL BUILDING SEE NOTE 4
TUNNEL Electrical, potential burn hazard, difficulat retrieval PERMIT REQUIRED SERVICE BUILDING TO BACK OF PILOT WING
COM. MANHOLE (MAIN LOT) Electrical Hazards, Potential for insufficient Oxygen PERMIT REQUIRED COM. MANHOLE (MAIN LOT) OF ERRC
ELECTRICAL MANHOLES, (5) Electrical Hazards, Potential for insufficient Oxygen PERMIT REQUIRED 5 ELECTRICAL MANHOLES
SANITARY MANHOLES, (12)
Toxic Gases, Sewer Gas, Methane, insufficient oxygen, bacteria potential, slip
PERMIT REQUIRED VARIOUS LOCATIONS ON FACILITY
STORM MANHOLES, (8)
Toxic Gases, Sewer Gas, Methane, insufficient oxygen, bacteria potential, slip
PERMIT REQUIRED VARIOUS LOCATIONS ON FACILITY
COM. MANHOLE Electrical Hazards, Potential for insufficient Oxygen PERMIT REQUIRED SERVICE BUILDING BEHIND BOILER #4
BOILERS (4)
Extremely tight space for entry and work, potential for oxygen deficiency, heat and burn hazards if not properly cooled and secured, PERMIT REQUIRED SERVICE BUILDING TO BACK OF PILOT WING
COOLING TOWERS (4)
Mechanical Parts - rotating fans and associated equipment, electrical hazards, water hazard in well, pressurized water hazard
NON-PERMIT GROUNDS ADJACENT TO SERVICE BUILDING SEE NOTE 1
FUEL STORAGE TANKS
Tight entry via manways, potential for hazardous atmosphere and fire, potential for insufficient oxygen, slip
PERMIT REQUIRED GROUNDS BEHIND COOLING TOWERS
ADMIN WING FREIGHT ELEVATOR PIT Mechanical , Electrical NON-PERMIT ADMIN WING SEE NOTE 3 ADMIN WING PASSENGER ELEVATOR PIT Mechanical , Electrical NON-PERMIT ADMIN WING SEE NOTE 3 CHEM WING ELEVATOR PIT Mechanical , Electrical NON-PERMIT CHEM WING SEE NOTE 3 PILOT WING FREIGHT ELEVATOR PIT Mechanical , Electrical NON-PERMIT PILOT WING SEE NOTE 3 ADMIN WING HANDICAP ELEVATOR PIT Mechanical , Electrical NON-PERMIT ADMIN WING LOBBY SEE NOTE 3 MSB FREIGHT ELEVATOR Mechanical , Electrical NON-PERMIT msb BUILDING SEE NOTE 3
CHEM WING, AHU-1
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT CHEM WING MECHANICAL ROOM 0128 SEE NOTE 2
CHEM WING, AHU-2
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT CHEM WING MECHANICAL ROOM 0116 SEE NOTE 2
CHEM WING, AHU-3
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT CHEM WING MECHANICAL ROOM 0104 SEE NOTE 2
CHEM WING RTU-1
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT CHEM WING ROOF SEE NOTE 2
CHEM WING RTU-2
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT CHEM WING ROOF SEE NOTE 2
CHEM WING RTU-3
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT CHEM WING ROOF SEE NOTE 2
AHU G-K
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT ADMIN WING SEE NOTE 2
ATTACHMENT A.1.2, LIST OF KNOWN CONFINED SPACES
DESCRIPTION HAZARD PERMITTING REQUIREMENT LOCATION REMARKS
AHU-H
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT ADMIN WING SEE NOTE 2
AHU I-J
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT ADMIN WING SEE NOTE 2
PILOT WING, AHU-7
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT PILOT WING MECHANICAL ROOM, 0204 SEE NOTE 2
PILOT WING, AHU-1
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT PILOT WING MECHANICAL ROOM, 0206 SEE NOTE 2
PILOT WING, AHU-2
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT PILOT WING HIGH BAY, 2ND FLOOR SEE NOTE 2
PILOT WING, AHU-3
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT PILOT WING HIGH BAY, 3RD FLOOR SEE NOTE 2
PILOT WING, AHU-4
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT PILOT WING ATTIC SEE NOTE 2
PILOT WING, AHU-5
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT PILOT WING HIGH BAY, 3RD FLOOR SEE NOTE 2
PILOT WING, AHU-6
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT PILOT WING HIGH BAY, 3RD FLOOR SEE NOTE 2
PILOT WING RTU-4
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT PILTO WING ROOF SEE NOTE 2
MSB AIR HANDLERS (3)
Mechanical Parts - rotating fans and associated equipment, electrical hazard
NON-PERMIT MSB BUILDING SEE NOTE 2
HAZ-OPS BILCO HAZOPS BUILDING
MSB 2ND FLOOR PIPE CHASE Tight working space, limited exgress NON-PERMIT MSB , 2ND FLOOR ADMIN WING LOW ROOF CRAWL SPACES potential mechanical and electrical equipment hazards CHEM WING
Note 1, Cooling Towers are non-permit required confined spaces for normal entries if the equipment is fully de-energized (LO/TO) per the applicable procedure. All electrical energy, make up supply water (if applicable) and chemical pumps (if applicable) to associated cooling tower equipment must be de-energized and controlled before entry. The cooling tower becomes permit required if any kind of welding, cutting or burning is completed or chemicals are used that release fumes or vapors within the cooling tower enclosure. Ventilate with portable fans as necessary to remove any fumes or vapors from work processes.
Note 2, Air Handlers are non-permit required confined spaces for normal entries if the equipment is fully de-energized (LO/TO) per the applicable procedure. The air handler becomes permit required if any kind of welding, cutting or burning is completed or chemicals are used that release fumes or vapors within the air handler enclosure. Ventilate with portable fans as necessary to remove any fumes or vapors from work processes.
Note 3, These areas are non-permit required confined spaces for normal entries if elevator equipment is fully de-energized (LO/TO) per the applicable procedure. The area becomes permit required if any kind of welding, cutting or burning is completed or chemicals are used that release fumes or vapors within the area.
Note 4, These areas are non-permit required confined spaces for normal entries if all equipment is fully de-energized (LO/TO) per the applicable procedure. All electrical energy, pumps (if applicable) and equipment with the potential to create a hazardous condition must be de-energized and controlled before entry. The area becomes permit required if any kind of welding, cutting or burning is completed or chemicals are used that release fumes or vapors within the area.
Sheet1
File details come from the government source that posted it.