OMB Control No. 2120-0595 (SF-30) FAA Template No. 11 (Reverse) (8/97)

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES

1 1

2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)

03 3-5-2018 848465

6. ISSUED BY 7. ADMINISTRATED BY (If other than Item 6)

USDA Forest Service Mt. Baker-Snoqualmie National Forest Attn: Brian A. Johnson, CO 2930 Wetmore Ave., Suite 3A Everett, WA 98201

Same as Block 6

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) 9A. AMENDMENT OF SOLICITATION NO.

1205G118R0011

9B. DATED (SEE ITEM 11)

1-29-2018

10A. MODIFICATION OF CONTRACT/ORDER NO.

*TO BE COMPLETED BY VENDOR IF NOT COMPLETE 10B. DATED (SEE ITEM 13)

CODE FACILITY CODE

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended is not extended.

NOTE: If offers are handcarried, additional time should be allowed to access the depository facility due to heightened security requirements.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing Item 8 and 15, and returning 1 copies of the amendment; (b) acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hours and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required) N/A

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS, IT MODIFIES THE CONTRACT/ORDER NO.

AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT/ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return Zero (0) copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

1. The purpose of Amendment 03 is to replace page 78 (Spec 08 14 16) and pages 173-174 (Spec 28 13 00) as provided in this amendment. Please note that page 174 is not amended, but information from Page 173 is now continued on Page 174 in order to fit page 173 changes.

2. If there are any questions contact the undersigned at (425) 783-6056 or bajohnson03@fs.fed.us.

(Continued…) 15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

Brian A. Johnson 15B. CONTRACTOR/OFFEROR 15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 16C. DATE SIGNED

BY

(Signature of person authorized to sign)

BY

(Signature of Contracting Officer) 3-5-2018 mailto:bajohnson03@fs.fed.us

2.02 NEW FIRE DOOR #8

A. Fire-Rated Wood Doors: Doors complying with NFPA 80 that are listed and labeled by a qualified testing agency, for fire-protection ratings indicated, based on testing at positive pressure according to NFPA 252 or UL 10C. Fire rated glazing. The size of the view light shall be 18" x 18" with glazing specified in 2.04 below.

2.03 FRAMES

A. Replace door frames only if needed to accommodate door hardware changes.

B. Heavy-Duty Frames: SDI A250.8, Level 2. Physical Performance: Level B according to

SDI A250.4.

2.04 GLAZING

A. Door #7: Glazing to conform to UL 752 of the following protection level. 9/16" (14.3 mm) laminated infill with 0.090" (3 mm) PVB interlayer.

3. PART 3-EXECUTION

A. INSTALLATION

B. Install new doors 7 and 8.

C. Salvage/recycle existing doors.

D. Clearances: Provide 1/8 inch (3.2 mm) at heads, jambs, and between pairs of doors.

Provide 1/8 inch (3.2 mm) from bottom of door to top of decorative floor finish or covering unless otherwise indicated. Where threshold is shown or scheduled, provide 1/4 inch (6.4

mm) from bottom of door to top of threshold unless otherwise indicated.

E. Set frames to maintain dimensions, hold head level, and jambs plumb and square. Anchor securely to adjacent construction.

F. Fit, hang, and trim wood doors to match the appearance of the existing doors. Adjust doors to operate without binding.

G. Operation: Rehang or replace doors that do not swing or operate freely.

END OF SECTION

RFP No. 1205G118R0011 Building #2002 Colville SO, Entrance Security Page 78 of 277

(Amendment 03) bajohnson03 Highlight bajohnson03 Highlight

C. Features:

1. 12 or 24 VDC input power.

2. Supports Data1/Data0, Clock/Data and compatible RS-485 readers and keypads

3. Downloadable firmware.

4. 6 Form-C 5 A, 30 VDC relay outputs.

5. Up to 16 different formats (8 card formats and 8 asset formats).

6. Issue code support for magnetic and Wiegand formats.

7. Door contact supervision (open/closed).

8. REX push-button monitor.

9. Strike control output.

10. Bicolor reader status LED support and 2-wire LED support.

11. Beeper control.

12. Dedicated tamper and power failure circuit.

13. Support for offline reader access mode.

14. On-board termination jumpers.

15. On-board regulator allows 12 VDC reader support from 24 VDC power source.

16. DIP switch-selectable addressing.

17. Two (2) Wire RS-485 communications shall be Belden 9842, 2P, 24 AWG, overall shield or approved equal for local code compliance

18. Reader communications for Weigand shall be 6 conductor, overall shield, 22/24

AWG Belden 5504E/9536 or equal.

2.08 ACCESS CARD READERS, WALL MOUNTED

A. Manufacturers:

1. HID 920PHPTEK000HU-L02 - RP40 PIVClass Multi-technology Reader, Terminal Block, 485HDX, 200 bit

2. Card readers must be tested by ePACS PMO office to be compatible with regional

EPACS server and required Lincpass and Corporate 1000 cards.

B. Product Description: FIPS 201-2 compliant proximity access card reader with 200 bit encryption.

C. Frequency: 13.56 MHz.

D. Must be compatible with HSPD-12 LincPass cards and HID Corporate 1000 cards.

E. Read Range: Provide access at distances between 0 and 6 inches from the reader.

F. Color: Black.

G. Product Description: iClass (USDA HSPD-12 Linc Pass compatible) Card swipe proximity reader in cast aluminum housing suitable for installation in interior and exterior locations subjected to weather.

H. The current HID card readers ship with OSDP enable configuration; USDA's access control system utilizes mag/Weigand output. Rewire the card readers for the mag/ Weigand output and reflash the card readers to enable the mag/Weigand output. The following configuration flash card is required to perform the flash function:

2.09 ACCESS CARD READERS, MULLION MOUNTED

RFP No. 1205G118R0011 Building #2002 Colville SO, Entrance Security Page 173 of 277

(Amendment 03) bajohnson03 Highlight bajohnson03 Highlight bajohnson03 Stamp

2. Card readers must be tested by ePACS PMO office to be compatible with regional EPACS server and required Lincpass and Corporate 1000 cards.

B. Product Description: FIPS 201-2 compliant proximity access card reader with 200 bit output.

C. Frequency: 13.56 MHz.

D. Must be compatible with HSPD-12 LincPass cards and HID Corporate 1000 cards.

E. Read Range: Provide access at distances between 0 and 6 inches from the reader.

F. Color: Black.

G. Product Description: iClass (USDA HSPD-12 Linc Pass compatible) Card swipe proximity reader in cast aluminum housing suitable for installation in interior and exterior locations subjected to weather.

2.10 ACCESS CARD READERS, WALL MOUNTED WITH KEYPADS

A. Manufacturers: HID B. 921PHPTEK000HV-L02 HID - RPK40 PIVClass Multi-technology Reader, Terminal

Block, 485HDX, 200 bit (Keypad) C. Substitutions: Not Permitted.

D. Product Description: FIPS 201 compliant combination keypad and proximity access card reader with 200 bit encryption.

E. Frequency: 13.56 MHz.

F. Read Range: Provide access at distances between 0 and 6 inches from the reader.

G. Color: Black.

2.11 LINCPASS BADGE CARDS (GOVERNMENT FURNISHED FOR PROGRAMMING)

A. Permanent Government employees have HSPD-12 approved LincPass cards. These cards shall be required to be read and used for this system to access building. Card readers and controller boards must support these cards for access control.

B. Enter each employee’s LincPass card data into the system and download from the enterprise server each person’s credentials. For this project no more than 80 LincPass cards need to be entered into ACS.

C. Assign access levels for each card.

2.12 CORPORATE 1000 BADGE CARDS

A. Provide 150 corporate 1000 Cards for use in this systems by manufacturer of card reader.

B. These shall be USDA serialized cards issued to the VAR for this project.

C. Substitutions not permitted.

D. Provide HID corporate 1000 cards model: 1386LGGMN (Verify with USDA prior to ordering) E. Enter all corporate 1000 cards for use in this system for persons that do not have

LincPass cards. For this project 150 Cards need to be entered into ACS, F. Assign access levels for each card.

G. See part 3 this section for additional information on programming and printing.

RFP No. 1205G118R0011 Building #2002 Colville SO, Entrance Security Page 174 of 277 A. Manufacturers: HID

1. 900PHPTEK000HU-L02 HID - RP10 PIVClass Multi-technology Reader, Terminal Block, 485HDX, 200 bit (Mullion)

2018-03-05T15:29:44-0800
BRIAN JOHNSON

File details come from the government source that posted it.