FA_18-0927_4534_CRG_office.pdf
PDF 1 MB Posted
- Attached to
- TNF Fire Alarm Annual Inspection Federal contract opportunity
- Solicitation number
- 12010919Q0068
About this file
Craig Office
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA_18-0924_4506_KTN_whse.pdf | ||
| FA_18-0925_4523_WRG_office.pdf | ||
| FA_18-0926_4530_TNB_office.pdf | ||
| FA_18-0919_4480_JNU_office.pdf | ||
| FA_18-0925_4524_WRG_whse.pdf | ||
| FA_18-0926_4531_TNB_whse.pdf | ||
| FA_18-0924_4515_SEADC.PDF | ||
| FA_18-0919_4475_JNU_bunkhouse.pdf | ||
| FA_18-0924_4507_KTN_bunkhouse.pdf | ||
| FA_18-0924_4505_KTN_office.pdf | ||
| FA_18-0815_4396_Sitka_office.pdf | ||
| SKM_C45819062319260.pdf | ||
| FA_18-0919_4470_MGVC.PDF | ||
| FA_18-0917_4461_JNU_FSL.PDF | ||
| FA_18-0918_4463_HNH_office.pdf | ||
| wage_determination.pdf | ||
| 12010919Q0068_Solicitation_for_Fire_Alarm_Inspection.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USDA Forest Service - Tongass Craig Office
No.
04534 www.gocanvas.com EA3EAFE3-A9D7-415C-B77B-E8248373D89E
725 W. Wasair Dr. Wasilla, AK 99654 907-373-1760 www.taylorfire.com
Fire Alarm Inspection Report Status
Status
Date 09/27/2018
Time 20:25
Owner /Client / Contracting Agency
Name USDA Forest Service - Tongass Address 1 2108 Halibut Point Rd Address 2
City Sitka State
AK
Zip 99835
Representative
Telephone
Fax
Property Name (User)
Name Craig Office Address 1 900 9th Street Address 2
City Craig State
AK
Contact
Telephone http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04534 www.gocanvas.com EA3EAFE3-A9D7-415C-B77B-E8248373D89E
Zip 99925
Monitoring Entity
Contact / Agency None
Telephone N/A
Monitoring Account Ref. No.
N/A
Approving Agency
Contact N/A
Telephone N/A
Service
Service Annually
Other (Specify)
Prior To Any Testing Notifications Are
Made To Other (Specify) Yes/No Who Time
Building Management Yes 20:32
Type Transmission
Type Transmission Other
Other (Specify)
Control Panel
Control Panel Manufacturer
EST
Control Panel Model
EST-1
Control Panel Location
FRONT ENTRY
Is Panel in "normal" conditions upon arrival?
YES
Circuit Styles
IDC
Number of Circuits
Software Rev.
N/A Last Date System Had Any Service Performed Last Date that Any Software or Configuration Was Revised N/A
Printer http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04534 www.gocanvas.com EA3EAFE3-A9D7-415C-B77B-E8248373D89E
Printer Model N/A Location N/A
Did Printer Function Properly N/A Is Printer Supervised?
N/A
Alarm-Initiating Devices and Circuit Information Description If Other
(Specify) Quantity of
Devices Installed
Quantity of Devices Tested
Quantity of Devices Passed
Quantity of Devices
Failed
Circuit Style
Manual Fire Alarm Boxes
7 7 7 0
Smoke Detectors 11 11 11 0 Heat Detectors 1 1 1 0
Alarm Verification
Alarm Verification feature is Disabled
Alarm Notification Appliances & Circuit Info Description If Other
(Specify) Quantity of Appliances
Installed
Quantity of Appliances
Tested
Quantity of Devices Passed
Quantity of Devices
Failed
Circuit Style
Horn/Strobes 7 7 7 0 Bells 1 1 1 0
Alarm Notification Circuits
No. of alarm notification appliance circuits
Are circuits monitored for integrity?
Yes
Initiating Device Circuit
Quantity
Style(s)
CLASS B
Signaling Line Circuits
Quantity and style of signaling line circuits connected to system (see 2007 NFPA 72, Table 6.6.1) Quantity
Style(s)
System Primary Power Supply http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04534 www.gocanvas.com EA3EAFE3-A9D7-415C-B77B-E8248373D89E
(a) Primary (Main) Location (of Primary Supply Panelboard)
BOILER ROOM
Nominal Voltage 120/208
Amps Overcurrent Protection Type
BREAKER
Overcurrent Protection Amps
Disconnecting Means Location
BREAKER 4
Secondary (standby) Power Supply Type Location Battery
Dated:
Storage Battery:
Amp Hour Rating
Battery Type
Other Battery
Type
Calculated capacity in Amp-Hours to operate system for 24 hours.
Calculated capacity in Amp-Hours to operate system for 60 hours.
Control Panel IN PANEL 09/2010 12/7 Sealed Lead- Acid
Secondary (standby) Power Primary Power Supply Location of
Primary Power Supply
(Distribution Panel)
Nominal Voltage of Primary Power
Supply
Amps of Primary Power Supply
Overcurrent Protection Type
Overcurrent Protection Amps
Disconnecting Means Location
Generator System
Engine-driven generator dedicated to fire alarm system.
N/A
Location of fuel storage:
N/A
Other Backup
(c) Emergency or standby system used as a backup to primary power supply, instead of using a secondary power supply:
N/A
Emergency system described in NFPA 70, Article 700
Legally required standby described in NFPA 70, Article 701 Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701
System Tests And Inspections Type Visual Functional Comments
Control Unit Interface Equipment Lamps/LEDS Fuses Primary Power Supply Trouble Signals Disconnect Switches http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04534 www.gocanvas.com EA3EAFE3-A9D7-415C-B77B-E8248373D89E
Type Visual Functional Comments Ground-Fault Monitoring Secondary Power
Type Visual Functional Comments Battery Condition BATTERIES DUE FOR
REPLACEMENT
Transient Suppressors
Transient Suppressors Visual
Comments
Notification Appliances Notification Appliances Visual Functional Comments
Audible/Visual Combination Audible
Notifications That Testing is Complete Notification Given
To Other (Specify) Yes/No Who Time
Building Management Yes 20:41
Deficiencies and Issues
The following did not operate correctly
*BATTERIES DUE FOR REPLACEMENT
**HEAT DETECTORS DUE FOR TEST/REPLACEMENT
***SYSTEM NOT MONITORED RECOMMEND GETTING IT
MONITORED
System restored to normal operation
Date 09/27/2018 Time 20:41 http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04534 www.gocanvas.com EA3EAFE3-A9D7-415C-B77B-E8248373D89E
Pictures
Photo 1
Photo 1 Description
BREAKER PANEL FOR FACP
Photo 2
Photo 2 Description
OUTSIDE HORNSTROBE ON SITE
Photo 3
Photo 3 Description
CONFIRMED AC POWER LOSS
Photo 4
Photo 4 Description
HEAT DETECTORS ON SITE
Photo 5
Photo 5 Description
OUTSIDE BELL ON SITE
Photo 6
Photo 7 Photo 8 Photo 9 http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04534 www.gocanvas.com EA3EAFE3-A9D7-415C-B77B-E8248373D89E
Photo 8 Description
BATTERIES IN FACP
Photo 9 Description
DIALER HOOKED UP BUT WASNT
SENDING SIGNALS
Photo 10 Photo 11
Notes and Recommendations
Notes and Recommendations
No.
04534 www.gocanvas.com EA3EAFE3-A9D7-415C-B77B-E8248373D89E
Plan of Corrective Action:
CONTACT TAYLOR FIRE 907-373-1760
Corrective Action and Date Taken:
Inspector Information
This testing was performed in accordance with (Standard/Edition)
NFPA 72
Name of Inspector
ALEXANDER MARTINEZ
License Number 10-009
Date 09/27/2018 Time 20:53
Inspector Signature
Inspector Signature
Owner or Representative Information
Name of Owner or Representative
Date 09/27/2018
Time 20:53
Owner or Representative Signature
Owner or Representative Signature http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link