FA_18-0918_4463_HNH_office.pdf
PDF 1 MB Posted
- Attached to
- TNF Fire Alarm Annual Inspection Federal contract opportunity
- Solicitation number
- 12010919Q0068
About this file
Hoonah Office
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA_18-0924_4506_KTN_whse.pdf | ||
| FA_18-0925_4523_WRG_office.pdf | ||
| FA_18-0919_4480_JNU_office.pdf | ||
| FA_18-0925_4524_WRG_whse.pdf | ||
| FA_18-0926_4531_TNB_whse.pdf | ||
| FA_18-0924_4515_SEADC.PDF | ||
| FA_18-0919_4475_JNU_bunkhouse.pdf | ||
| FA_18-0924_4507_KTN_bunkhouse.pdf | ||
| FA_18-0924_4505_KTN_office.pdf | ||
| FA_18-0926_4530_TNB_office.pdf | ||
| FA_18-0927_4534_CRG_office.pdf | ||
| FA_18-0815_4396_Sitka_office.pdf | ||
| SKM_C45819062319260.pdf | ||
| FA_18-0919_4470_MGVC.PDF | ||
| FA_18-0917_4461_JNU_FSL.PDF | ||
| 12010919Q0068_Solicitation_for_Fire_Alarm_Inspection.pdf | ||
| wage_determination.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USDA Forest Service - Tongass Hoonah Office
No.
04463 www.gocanvas.com CE22D8F0-5A58-49DD-AEF3-EAA9DA0EC87B
725 W. Wasair Dr. Wasilla, AK 99654 907-373-1760 www.taylorfire.com
Fire Alarm Inspection Report Status
Status
Date 09/18/2018
Time 08:00
Owner /Client / Contracting Agency
Name USDA Forest Service - Tongass Address 1 2108 Halibut Point Rd Address 2
City Sitka State
AK
Zip 99835
Representative
Telephone
Fax None Email None
Property Name (User)
Name Hoonah Office Address 1 430 Airport Road Address 2
City Hoonah State
AK
Contact
Telephone http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04463 www.gocanvas.com CE22D8F0-5A58-49DD-AEF3-EAA9DA0EC87B
Zip 99829
Monitoring Entity
Contact / Agency None
Monitoring Account Ref. No.
Approving Agency
Contact
Service
Service Annually
Other (Specify)
Prior To Any Testing Notifications Are
Made To Other (Specify) Yes/No Who Time
Building Occupants Yes On site personnel 08:01
Type Transmission
Type Transmission Other
Other (Specify) None
Control Panel
Control Panel Manufacturer
SIMPLEX
Control Panel Model
Control Panel Location
FRONT ENTRY
Is Panel in "normal" conditions upon arrival?
Yes Circuit Styles
IDC
Number of Circuits
Software Rev.
N/A Last Date System Had Any Service Performed
PREVIOUS ANNUAL INSPECTION
Last Date that Any Software or Configuration Was Revised None
Printer http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04463 www.gocanvas.com CE22D8F0-5A58-49DD-AEF3-EAA9DA0EC87B
Printer Model
Location
Did Printer Function Properly
Is Printer Supervised?
Alarm-Initiating Devices and Circuit Information Description If Other
(Specify) Quantity of
Devices Installed
Quantity of Devices Tested
Quantity of Devices Passed
Quantity of Devices
Failed
Circuit Style
Manual Fire Alarm Boxes
3 3 3 0 CLASS B
Smoke Detectors 16 16 16 0 CLASS B
Alarm Verification
Alarm Verification feature is Disabled
Alarm Notification Appliances & Circuit Info Description If Other
(Specify) Quantity of Appliances
Installed
Quantity of Appliances
Tested
Quantity of Devices Passed
Quantity of Devices
Failed
Circuit Style
Horn/Strobes 2 2 2 0 CLASS B Decibel Levels
Location Description Ambient Level Alarm Level Entire building 55-58 105
Alarm Notification Circuits
No. of alarm notification appliance circuits
Are circuits monitored for integrity?
Yes
Initiating Device Circuit
Quantity
Style(s)
CLASS B
Signaling Line Circuits
Quantity and style of signaling line circuits connected to system (see 2007 NFPA 72, Table 6.6.1) Quantity
Style(s)
CLASS B
http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04463 www.gocanvas.com CE22D8F0-5A58-49DD-AEF3-EAA9DA0EC87B
System Primary Power Supply
(a) Primary (Main) Location (of Primary Supply Panelboard)
IN COPY RM
Nominal Voltage 120/208
Amps Overcurrent Protection Type
BREAKER
Overcurrent Protection Amps
Disconnecting Means Location
UPS 25
Secondary (standby) Power Supply Type Location Battery
Dated:
Storage Battery:
Amp Hour Rating
Battery Type
Other Battery
Type
Calculated capacity in Amp-Hours to operate system for 24 hours.
Calculated capacity in Amp-Hours to operate system for 60 hours.
Control Panel FRONT
ENTRY
1/14 7/12 Sealed Lead- Acid
N/A N/A N/A
Secondary (standby) Power Primary Power Supply Location of
Primary Power Supply
(Distribution Panel)
Nominal Voltage of Primary Power
Supply
Amps of Primary Power Supply
Overcurrent Protection Type
Overcurrent Protection Amps
Disconnecting Means Location
Same as above 120 20 BREAKER 20 Ups 25
Generator System
Engine-driven generator dedicated to fire alarm system.
Location of fuel storage:
Other Backup
(c) Emergency or standby system used as a backup to primary power supply, instead of using a secondary power supply:
None
Emergency system described in NFPA 70, Article 700
Legally required standby described in NFPA 70, Article 701 Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701
System Tests And Inspections Type Visual Functional Comments
Control Unit Interface Equipment Lamps/LEDS Fuses Primary Power Supply Trouble Signals Disconnect Switches Ground-Fault Monitoring http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04463 www.gocanvas.com CE22D8F0-5A58-49DD-AEF3-EAA9DA0EC87B
Secondary Power Type Visual Functional Comments
Battery Condition Load Voltage Discharge Test Charger Test
Transient Suppressors
Transient Suppressors Visual
Comments
Notification Appliances Notification Appliances Visual Functional Comments
Audible/Visual Combination
Initiating & Supervisory Device Tests & Inspection Device
Type Loc. & S/N Visual
Check Functional
Test Factory Setting
Measured Setting
Pass/Fail Comments
Pulls Entry exit points
Pass
Smokes Ceilings located through out
Pass
Notifications That Testing is Complete Notification Given
To Other (Specify) Yes/No Who Time
Building Management Yes CHRIS 11:53
Deficiencies and Issues
The following did not operate correctly
EVERYTHING OPERATED AND PERFORMED PER NFPA
72 STANDARDS
System restored to normal operation
Date 09/18/2018 Time 11:53 http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04463 www.gocanvas.com CE22D8F0-5A58-49DD-AEF3-EAA9DA0EC87B
Pictures
Photo 1
Photo 1 Description Power supply
Photo 2
Photo 2 Description Alarm Db reading
Photo 3
Photo 3 Description Smokes
Photo 4
Photo 4 Description Pulls
Photo 5
Photo 5 Description Tested on battery backup
Photo 6
Photo 6 Description Panel conductors
Photo 7 Photo 8 Photo 9 http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04463 www.gocanvas.com CE22D8F0-5A58-49DD-AEF3-EAA9DA0EC87B
Photo 7 Description Battery info
Photo 8 Description Panel info
Photo 9 Description Panel info
Notes and Recommendations
Notes and Recommendations None Plan of Corrective Action:
**CONTACT TAYLOR FIRE @907-373-1760 FOR P.O.C.A
Corrective Action and Date Taken:
**NONE TAKEN AT THIS TIME
Inspector Information
This testing was performed in accordance with (Standard/Edition)
CURRENT NFPA 72 STANDARDS
Name of Inspector
ALEXANDER MARTINEZ
License Number 10-009
Date 09/18/2018 Time 11:55
Inspector Signature
Inspector Signature http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04463 www.gocanvas.com CE22D8F0-5A58-49DD-AEF3-EAA9DA0EC87B
Owner or Representative Information
Name of Owner or Representative
CHRIS
Date 09/18/2018
Time 11:55
Owner or Representative Signature
Owner or Representative Signature http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link