FA_18-0815_4396_Sitka_office.pdf
PDF 1 MB Posted
- Attached to
- TNF Fire Alarm Annual Inspection Federal contract opportunity
- Solicitation number
- 12010919Q0068
About this file
Sitka Office
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA_18-0924_4506_KTN_whse.pdf | ||
| FA_18-0925_4523_WRG_office.pdf | ||
| FA_18-0926_4530_TNB_office.pdf | ||
| FA_18-0927_4534_CRG_office.pdf | ||
| FA_18-0919_4480_JNU_office.pdf | ||
| FA_18-0925_4524_WRG_whse.pdf | ||
| FA_18-0926_4531_TNB_whse.pdf | ||
| FA_18-0924_4515_SEADC.PDF | ||
| FA_18-0919_4475_JNU_bunkhouse.pdf | ||
| FA_18-0924_4507_KTN_bunkhouse.pdf | ||
| FA_18-0924_4505_KTN_office.pdf | ||
| SKM_C45819062319260.pdf | ||
| FA_18-0919_4470_MGVC.PDF | ||
| FA_18-0917_4461_JNU_FSL.PDF | ||
| FA_18-0918_4463_HNH_office.pdf | ||
| wage_determination.pdf | ||
| 12010919Q0068_Solicitation_for_Fire_Alarm_Inspection.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USDA Forest Service - Tongass Sitka Ranger Station
No.
04396 www.gocanvas.com 299923EC-ED16-4A61-A27B-8608E0AC7436
725 W. Wasair Dr. Wasilla, AK 99654 907-373-1760 www.taylorfire.com
Fire Alarm Inspection Report Status
Status
Date 08/15/2018
Time 17:58
Owner /Client / Contracting Agency
Name USDA Forest Service - Tongass Address 1 2108 Halibut Point Rd Address 2
City Sitka State
AK
Zip 99835
Representative
LOGAN WILD
Telephone 907-747-4349 Fax None Email
NLWILD02@FS.FED.US
Property Name (User)
Name Sitka Ranger Station Address 1 99835 Halibut Point Road Address 2
City Sitka State
AK
Contact Same Telephone Same http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04396 www.gocanvas.com 299923EC-ED16-4A61-A27B-8608E0AC7436
Zip 99835
Monitoring Entity
Contact / Agency
LJ ALARM
Telephone 789-7940
Monitoring Account Ref. No.
Approving Agency
Contact
USDA
Telephone
Service
Service Annually
Other (Specify)
Prior To Any Testing Notifications Are
Made To Other (Specify) Yes/No Who Time
Building Management Yes RYAN ON SITE
MANAGER
18:07
Type Transmission
Type Transmission Digital
Other (Specify)
Control Panel
Control Panel Manufacturer
SIMPLEX
Control Panel Model
4100ES
Control Panel Location
COMM RM
Is Panel in "normal" conditions upon arrival?
Yes Circuit Styles
SLC
Number of Circuits
Software Rev.
N/A Last Date System Had Any Service Performed
PREVIOUS ANNUAL INSPECTION
Last Date that Any Software or Configuration Was Revised
INSTALL
Printer http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04396 www.gocanvas.com 299923EC-ED16-4A61-A27B-8608E0AC7436
Printer Model None Location
Did Printer Function Properly
Is Printer Supervised?
Alarm-Initiating Devices and Circuit Information Description If Other
(Specify) Quantity of
Devices Installed
Quantity of Devices Tested
Quantity of Devices Passed
Quantity of Devices
Failed
Circuit Style
Manual Fire Alarm Boxes
7 7 7 0 CLASS B
Smoke Detectors 38 38 38 0 CLASS B
Alarm Verification
Alarm Verification feature is Disabled
Alarm Notification Appliances & Circuit Info Description If Other
(Specify) Quantity of Appliances
Installed
Quantity of Appliances
Tested
Quantity of Devices Passed
Quantity of Devices
Failed
Circuit Style
Horn/Strobes 14 14 14 0 CLASS B Strobes 16 16 16 0 CLASS B Decibel Levels
Location Description Ambient Level Alarm Level
ENTIRE FACILITY 62-66 92-104
Alarm Notification Circuits
No. of alarm notification appliance circuits
Are circuits monitored for integrity?
Yes
Control Equipment Description of
Equipment If Other (Specify)
Quantity Installed
Quantity Tested Quantity Passed Quantity Failed
Elevator Recall 3 3 3 0 AHU Shutdown 1 1 1 0 Other SHUNT TRIP 1 1 1 0
Initiating Device Circuit
Quantity None
Style(s)
CLASS B
Signaling Line Circuits http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04396 www.gocanvas.com 299923EC-ED16-4A61-A27B-8608E0AC7436
Quantity and style of signaling line circuits connected to system (see 2007 NFPA 72, Table 6.6.1) Quantity
Style(s)
CLASS B
System Primary Power Supply
(a) Primary (Main) Location (of Primary Supply Panelboard)
NEXT TO FACP
Nominal Voltage 120/208
Amps Overcurrent Protection Type
BREAKER
Overcurrent Protection Amps
Disconnecting Means Location
NET1 - 70
Secondary (standby) Power Supply Type Location Battery
Dated:
Storage Battery:
Amp Hour Rating
Battery Type
Other Battery
Type
Calculated capacity in Amp-Hours to operate system for 24 hours.
Calculated capacity in Amp-Hours to operate system for 60 hours.
Control Panel IN FACP 6/16 12/25 Sealed Lead- Acid
N/A N/A N/A
Secondary (standby) Power Primary Power Supply Location of
Primary Power Supply
(Distribution Panel)
Nominal Voltage of Primary Power
Supply
Amps of Primary Power Supply
Overcurrent Protection Type
Overcurrent Protection Amps
Disconnecting Means Location
Same as facp 120 20 BREAKER 20 Same as facp
Generator System
Engine-driven generator dedicated to fire alarm system.
None
Location of fuel storage:
Other Backup
(c) Emergency or standby system used as a backup to primary power supply, instead of using a secondary power supply:
None
Emergency system described in NFPA 70, Article 700
Legally required standby described in NFPA 70, Article 701 Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701
System Tests And Inspections http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04396 www.gocanvas.com 299923EC-ED16-4A61-A27B-8608E0AC7436
Type Visual Functional Comments Control Unit Interface Equipment Lamps/LEDS Fuses Primary Power Supply Trouble Signals Disconnect Switches Ground-Fault Monitoring
Secondary Power Type Visual Functional Comments
Battery Condition Load Voltage Discharge Test Charger Test
Transient Suppressors
Transient Suppressors Visual
Comments
Remote Annunciators Remote Annunciators Location Visual Functional Comments
Remote Annunciator FRONT ENTRY
Notification Appliances Notification Appliances Visual Functional Comments
Audible/Visual Combination Audible
Initiating & Supervisory Device Tests & Inspection Device
Type Loc. & S/N Visual
Check Functional
Test Factory Setting
Measured Setting
Pass/Fail Comments
PULLS ENTRY EXIT
WAYS
Pass
SMOKES LOCATED
ENTIRE
BUILDING ON
CEILING
Pass
Emergency Communications Equipment Type Visual Functional Comments
Call-in Signal
Central Station Monitoring Type of Signal Yes/No Time Comments
Alarm Signal Yes 18:21 Trouble Signal Yes 18:21 http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04396 www.gocanvas.com 299923EC-ED16-4A61-A27B-8608E0AC7436
Type of Signal Yes/No Time Comments Supervisory Signal Yes 18:21 Alarm Restoration Yes 18:22 Trouble Signal Restoration Yes 18:22 Supervisory Restoration Yes 18:22 Notifications That Testing is Complete Notification Given
To Other (Specify) Yes/No Who Time
Monitoring Agency Yes LJ ALARM 18:22 Building Management Yes LOGAN WILD 18:22
Deficiencies and Issues
The following did not operate correctly
EVERYTHING OPERATED AND PERFORMED PER NFPA
72 STANDARDS
System restored to normal operation
Date 08/15/2018 Time 18:22 http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04396 www.gocanvas.com 299923EC-ED16-4A61-A27B-8608E0AC7436
Pictures
Photo 1
Photo 1 Description Ambient Db reading
Photo 2
Photo 2 Description Alarm Db reading
Photo 3
Photo 3 Description Circuit breaker location and in proper state prior to leaving breaker needs lock
Photo 4
Photo 4 Description Audibles tested on battery backup
Photo 5
Photo 5 Description Conductor integrity
Photo 6
Photo 6 Description Conductor integrity
Photo 7 http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04396 www.gocanvas.com 299923EC-ED16-4A61-A27B-8608E0AC7436
Photo 7 Description Battery information
Notes and Recommendations
Notes and Recommendations
** RECOMMEND ADDING CIRCUIT BREAKER LOCK ON BREAKER **
Plan of Corrective Action:
**CONTACT TAYLOR FIRE @907-373-1760 FOR P.O.C.A
Corrective Action and Date Taken:
**NONE TAKEN AT THIS TIME
Inspector Information
This testing was performed in accordance with (Standard/Edition)
CURRENT NFPA 72 STANDARDS
Name of Inspector
ALEXANDER MARTINEZ
License Number 10-009
Date 08/15/2018 Time 18:24
Inspector Signature
Inspector Signature http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
No.
04396 www.gocanvas.com 299923EC-ED16-4A61-A27B-8608E0AC7436
Owner or Representative Information
Name of Owner or Representative
LOGAN WILD
Date 08/15/2018
Time 18:24
Owner or Representative Signature
Owner or Representative Signature http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link
File details come from the government source that posted it.