12-IFC DRAWING SET - Muntz Library Stair Renovation.pdf
PDF 18 MB Posted
- Attached to
- Muntz Library Stair Renovation State and local contract opportunity
- Solicitation number
- RFP No. 750/25/26-006
- Issued by
- Sterling County, Texas
About this file
This is a construction drawing set for the Muntz Library Stair Renovation project at the University of Texas at Tyler in Tyler, Texas. The project involves the complete renovation of an existing open stair system within the library, including replacement of handrail and guardrail systems with new glass rail assemblies (basis of design: Livers Bronze Struct-U-Rail), full replacement of tile finishes at all stair treads, risers, and curbs across multiple floor levels, preparation and installation of new resilient flooring with cover base in existing tile areas, and painting of walls, curbs, and stair undersides. The drawing set comprises architectural plans across four floor levels (1st through 4th floors), demolition plans indicating removal of existing glass, chrome tube and handrail systems, brick tile floors, aluminum curb caps, and related materials, and detailed cross-sections and elevations of the new railing and finish conditions. The scope includes full-height glass wall preservation, temporary floor-to-ceiling barriers during construction to minimize dust spread, and temporary safety railings for stair openings.
The project specifications reference compliance with 2021 International Building Code, 2021 International Plumbing Code, 2021 International Mechanical Code, 2021 International Fire Code, 2023 National Electrical Code, 2021 International Energy Conservation Code, and 2012 Texas Accessibility Standards. Materials specified include Daltile ceramic tile (Reminiscent Aged Beige), Interface Level Set resilient flooring, Tarkett-Johnsonite rubber base, Benjamin Moore paint finish, Schluter transition and stair nosing trim, and Laticrete grout. The drawing set indicates base bid and alternate pricing options for flooring replacement on the first floor only, second floor only, or third and fourth floors only. The drawings were issued for construction on February 6, 2026, with project management by Trey Greer and architectural services provided by FitzPatrick Architects of Tyler, Texas. The project involves coordination across multiple construction trades and requires contractor verification of existing conditions prior to bid submission and shop drawing preparation.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| 9-Exhibit C - Sample Payment Bond.pdf | ||
| 7-Exhibit G - Respondents Pricing and Delivery Proposal.docx | DOCX document | |
| 3-Compiled Specs - Muntz Library Stair Renovation.pdf | ||
| 15-Library Stairs - RFP Agenda.pdf | ||
| 2-Exhibit E - VetHUB Subcontracting Plan.docx | DOCX document | |
| 14-Pre-Submittal Conference Sign-In Sheet - Muntz Library Stairs.pdf | ||
| 11-Exhibit A - Sample Agreement Between Owner and Contractor.doc | DOC document | |
| 6-Exhibit I - Uniform General Conditions.docx | DOCX document | |
| 8-Exhibit H - Owners Special Conditions.docx | DOCX document | |
| 1-Exhibit F - HSP Quick Checklist.pdf | ||
| 4-RFP 750-25-26-006 Library Stairs Renovation.doc | DOC document | |
| 13-ADDENDUM NO 1 to RFP 750-25-26-006.pdf | ||
| 10-Exhibit B - Sample Performance Bond.pdf | ||
| 5-Exhibit D - Campus Map.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N . C
O
LL
E G
E A
V E
S
U
IT
E
TY
LE
R
, T E
X A
S
3.
2.
in fo fit zp at ric ka rc hi te ct s.
co m
© 2026
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
1" ACTUAL
3/3/26
JOB NUMBER
SHEET NUMBER
25.102
DATE
TREY GREER
SHEET REVISION HISTORY
PROJECT MANAGER
UT
T
YL
ER
MU
NT
Z
LIB
RA
RY
S
TA
IR
RE
NO
VA
TI
ON
TY
LE
R , T
EX
AS
02/06/2026 ISSUED FOR CONSTRUCTION
UNIVERSITY OF TEXAS AT TYLER
MUNTZ LIBRARY STAIR RENOVATION
TYLER , TEXAS
Cover
1/19/23, 3:56 PMGoogle Maps
Page 1 of 2https://www.google.com/maps/@32.316683,-95.2462603,12z
N
OWNER
VICINITY MAP
UT TYLER
3900 UNIVERSITY BLVD.
TYLER, TEXAS 75799
CONTACT: DEMI BECKHAM
903-565-6407 dbeckham@uttyler.edu
CAMPUS MAP
INDEX OF DRAWINGS
TITLE SHEET
G001 INDEX/CONVENTIONS
D101 DEMOLITION PLANS
D102 DEMOLITION PLANS
D103 DEMOLITION PLANS
A101 FLOOR PLANS
A102 FLOOR PLANS
A103 FLOOR PLANS
A201 STAIR DETAILS
N . C
O
LL
E G
E A
V E
S
U
IT
E
TY
LE
R
, T E
X A
S
3.
2.
in fo fit zp at ric ka rc hi te ct s.
co m
© 2026
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
1" ACTUAL
3/3/26
JOB NUMBER
SHEET NUMBER
25.102
DATE
TREY GREER
SHEET REVISION HISTORY
PROJECT MANAGER
UT
T
YL
ER
MU
NT
Z
LIB
RA
RY
S
TA
IR
RE
NO
VA
TI
ON
TY
LE
R , T
EX
AS
02/06/2026 ISSUED FOR CONSTRUCTION
E
D
C
B
A
1 2 3 4 5 6
INDEX/
CONVENTIONS
G001
GC GENERAL CONTRACTOR
GEN GENERAL
GFI GROUND FAULT INTERRUPTER
GLU-LAM GLUE LAMINATED BEAM
GYP GYPSUM
H
HB HOSE BIB
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HANDRAIL
HS HANDICAP SIGN
HT HEIGHT
HVAC HEATING, VENTILATING, AND
AIR CONDITIONING
I
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
J
JT JOINT
K
KS KNEE SPACE
L
LAM LAMINAT(E) (ED)
LAV LAVATORY
LBS POUNDS
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONC LIMITS OF NEW CONSTRUCTION
LTG LIGHTING
M
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MECH MECHANICAL(LY)
MFG MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTL METAL
N
N NORTH
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER/DIMENSION
OFCI OWNER FURNISHED/
CONTRACTOR INSTALLED
OFD OVERFLOW DRAIN
OFOI OWNER FURNISHED/
OWNER INSTALLED
OH OVERHEAD
OL OCCUPANT LOAD
OPP OPPOSITE
OS OVERFLOW SCUPPER
P
PB PARKING BUMPER
PE TILT PANEL END
PERM PERMANENT(LY)
A
A/E ARCHITECT/ENGINEER
ACT ACOUSTIC CEILING TILE
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
AOR AREA OF REFUGE
APPROX APPROXIMATE(LY)
ARCH ARCHITECT(URAL)
AV AUDIO VISUAL
B
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BOTT BOTTOM
BRG BEARING
BUR BUILT UP ROOF
C
CAB CABINET
CB CHALK BOARD
CJ CONTROL/CONSTRUCTION JOINT
CL CENTERLINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CT CERAMIC TILE
D
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIST DISTANCE
DWG DRAWING
E
EA EACH
EIFS EXTERIOR INSULATION
FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC
EPS EXPANDED POLYSTERENE
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COLOR
EX EXAMPLE
EXIST EXISTING
EXP EXPAN(D) (SION)
EXT EXTERIORF
FA FIRE ALARM
FE FIRE EXTINGUISHER
FD FLOOR DRAIN
FF FINISH FLOOR
FFE FINISH FLOOR ELEVATION
FIN FINISH
FLR FLOOR(ING)
FT FEET
FTG FOOTING
G
GA GAUGE
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
PJ TILT PANEL JOINT
PL PLATE
PLAM PLASTIC LAMINATE
PLYWD PLYWOOD
PP POWER POLE
PR PAIR
PROJ PROJECT(ION) (OR)
PROP PROPERTY
PS PROJECTOR SCREEN
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PTD PAINTED
Q
QTY QUANTITY
R
R RADIUS RADII
RA RETURN AIR
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REFER(ENCE)
REG REGISTER
REINF REINFORC(E) (ED) (ING) (EMENT)
REQD REQUIRED
REV REVISE(D)
RM ROOM
RO ROUGH OPENING
S
SCH SCHEDULE
SF SQUARE FOOT
SIM SIMILAR
SOG SLAB ON GRADE
SPEC(S) SPECIFICATION(S)
SQ SQUARE
SS STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STO STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
T
T THERMOSTAT
T&G TONGUE AND GROOVE
TAS TEXAS ACCESSIBILITY STANDARDS
TB TACK BOARD
TEL TELEPHONE
TEMP TEMPORARY
THK THICK
TOP TOP OF PLATE
TV TELEVISION
TYP TYPICAL
U
UC UNDERCABINET
UG UNDERGROUND
UNO UNLESS NOTED OTHERWISE
V
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VWC VINYL WALL COVERING
W
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WH WATER HEATER
WP WATER PROOF
WT WEIGHT
WWF WELDED WIRE FABRIC
SHEET NUMBER
DRAWINGS ARE NUMBERED BY LOCATION WITHIN GRID AS
DETERMINED BY THE LEFT HAND CORNER OF THE DRAWING
G001 A
B
C
D
E
2 4 61 3 5
C2
D4
C4C1 C3 C5 C6
E1 E3 E5
D2 D6
B1 B2 B3 B4 B5 B6
A1 A2 A3 A4 A5 A6
E2 E4 E6
D1 D3 D5
PROJECT GENERAL NOTES
THE FOLLOWING PROJECT GENERAL NOTES APPLY TO THE
ENTIRE SET OF DRAWINGS AND ARE NOT SPECIFIC TO ANY
ONE DISCIPLINE, UNLESS OTHERWISE NOTED:
1. THE CONSTRUCTION DOCUMENTS (DRAWINGS AND
SPECIFICATIONS) ARE COMPLEMENTARY AND ESTABLISH
DETAILED MINIMUM REQUIREMENTS FOR THE DESIGN AND
CONSTRUCTION OF THE PROJECT.
2. THIS SET OF DRAWINGS, WHEN COMPLETE, CONSISTS OF ALL
DRAWINGS LISTED BY THE INDEX OF DRAWINGS. THE WORK
DESCRIBED BY THE DRAWINGS OF ANY ONE DISCIPLINE MAY
BE AFFECTED BY THE WORK DESCRIBED ON DRAWINGS OF
ANOTHER DISCIPLINE AND MAY REQUIRE REFERENCE TO
DRAWINGS OF ANOTHER DISCIPLINE.
PARTIAL SETS OF DRAWINGS ARE INCOMPLETE. DO NOT
DISTRIBUTE OR UTILIZE PARTIAL SETS OF DRAWINGS.
3. COLUMN GRID LINES IDENTIFIED BY A LETTER DESIGNATION
ARE PARALLEL, UNLESS OTHERWISE NOTED. COLUMN GRID
LINES IDENTIFIED BY A NUMBER DESIGNATION ARE PARALLEL
AND ARE PERPENDICULAR TO THOSE WITH LETTER
DESIGNATIONS, UNLESS OTHERWISE NOTED.
4. DISCIPLINE GENERAL NOTES, SYMBOLS AND DEFINITIONS
APPLICABLE TO EACH DISCIPLINE'S DRAWINGS MAY BE
FOUND AT THE FRONT OF EACH DISCIPLINE'S PORTION OF
THE SET OF DRAWINGS AND ARE LISTED AS PART OF THE
OVERALL PROJECT INDEX OF DRAWINGS.
5. THE 'ARCHITECTURAL' SERIES DRAWINGS TAKE PRECEDENCE
FOR THE FINISHED APPEARANCE AND LOCATION OF ALL
EXPOSED ELEMENTS OF THE WORK OF ALL TRADES,
INCLUDING THAT WORK WHICH IS ILLUSTRATED PRIMARILY
ON DRAWINGS OF OTHER DISCIPLINES.
6. THE DRAWINGS MAY MAKE REFERENCE TO AND/OR
ILLUSTRATE ITEMS WHICH ARE NOT PART OF THE WORK OF
THE CONTRACT. THESE "NOT IN CONTRACT" ITEMS AS
INDICATED ARE REFERENCED AND/OR ILLUSTRATED FOR THE
CONTRACTOR'S REFERENCE, INFORMATION AND
COORDINATION ONLY.
7. EXISTING CONDITIONS, IF SHOWN, ARE FROM AVAILABLE
RECORD DRAWINGS AND OR VISUAL FIELD SURVEYS. THE
CONTRACTOR SHALL VERIFY ACTUAL EXISTING CONDITIONS
AT THE SITE PRIOR TO SUBMITTING A BID, AND NOTIFY THE
ARCHITECT OF ANY DISCREPANCIES.
8. ALL PARTS OF THE WORK, INCLUDING MATERIALS, METHODS,
ASSEMBLIES, ETC., MUST COMPLY WITH THE REQUIREMENTS
OF THE GOVERNING CODES AND REGULATIONS OF ALL
FEDERAL, STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT, AS WELL AS THOSE
GREATER REQUIREMENTS INDICATED BY THE CONTRACT
DOCUMENTS. NO PART OF THE CONTRACT DOCUMENTS MAY
BE CONSTRUED TO REQUIRE OR PERMIT WORK CONTRARY
TO A GOVERNING CODE OR REGULATION.
9. THE CONTRACTOR SHALL ENDEAVOR TO IDENTIFY AND
NOTIFY THE ARCHITECT/ENGINEER OF CONFLICTS BETWEEN
THE WORK OF DIFFERENT PARTIES AT THE EARLIEST
POSSIBLE DATE SO AS TO ALLOW REASONABLE AND
ADEQUATE TIME FOR THE CONFLICT TO BE RESOLVED
WITHOUT DELAYING THE WORK. ALL DEVIATIONS FROM THAT
WHICH IS REQUIRED BY THE CONTRACT DOCUMENTS MUST
BE APPROVED IN ADVANCE BY THE ARCHITECT/ENGINEER
AND OWNER.
10. IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW AND
COORDINATE THE WORK OF ALL SUB-CONTRACTORS, TRADES
AND SUPPLIERS WITH THE REQUIREMENTS OF THE
CONTRACT BEFORE COMMENCING CONSTRUCTION, AND TO
ASSURE THAT ALL PARTIES ARE AWARE OF ALL
REQUIREMENTS, REGARDLESS OF WHERE THE
REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS,
WHICH MIGHT AFFECT THE WORK OF THAT PARTY.
ROOM NAME
ROOM NAME
A
E101
N
F1B
HI LO
#DrgID
#DrgIDAXXX
XX
AXXX
XX
AXXX
XX
AXXX
XX AX
XX
XX
AXXX
XX
AXXX
XX
AXXX
XX
AXXX
#DrgID
#DrgIDAXXX
A3
A4
XX
AXXX
XX
AXXX
XX
AXXX
11"1'-6" 15'-43/4" ±
BASE CABINET
UPPER CABINET
FLOOR DRAIN W/ SLOPED FLOOR
ELEMENT THAT OCCURS
ABOVE THE PLAN CUT
TYP DIM STRING (TO STUDS) - ±
INDICATES DIM THAT CAN ADJUST FOR
FIELD CONDITIONS
ELEV NUMBER
SHEET NUMBER
ELEV NUMBER
SHEET NUMBER
SECT NUMBER
SHEET NUMBER
DET NUMBER
SHEET NUMBER
DET NUMBER
SHEET NUMBER
A
C03
C03
A
EA
EA
FD
NEW WALL W/ INSUL
EXISTING WALL
EXISTING WALL TO DEMO
EXISTING STRUCTURAL GRID LINE
GENERAL OR DEMO NOTE
NEW STRUCTURAL GRID LINE
PARTITION TYP
EXISTING WINDOW TO DEMO
NEW WINDOW & WINDOW NUMBER
EXISTING WINDOW & WINDOW NUMBER
NEW DOOR & NUMBER
EXISTING DOOR & NUMBER
EXISTING DOOR TO DEMO
SHEET REVISION NUMBER
ROOM NAME & NUMBER
REVISION BUBBLE
NORTH ARROW
EXTERIOR ELEVATION
FIRE EXTINGUISHER & CABINET OR FIRE VALVE CABINET -
SEE SPECIFICATIONS FOR TYPES & PLAN DESIGNATIONS
INTERIOR ELEVATION
WALL/BUILDING SECTION
DETAIL MARK
DETAIL MARK/ENLARGED PLAN
NEW WALL
ACCESSIBLE PLUMBING FIXTURE
NON-ACCESSIBLE PLUMBING FIXTURE
SHEET INDEX
Subset ID D1
A1
A2
D101 D102 D103
A101 A102 A103
A201
DEMOLITION PLANS
DEMOLITION PLANS
DEMOLITION PLANS
FLOOR PLANS
FLOOR PLANS
FLOOR PLANS
STAIR & RAIL DETAILS
D5 ARCHITECTURAL ABBREVIATIONS
G001
A4 SHEET DIAGRAM
G001 SCALE: 1/4" = 1'-0"
A5 ARCHITECTURAL SYMBOL LEGEND
G001 0 2' 4' 8'
APPLICABLE BUILDING CODES:
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL FIRE CODE
2023 NATIONAL ELECTRICAL CODE
2021 INTERNATIONAL ENERGY CONSERVATION
CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 NFPA 101
N . C
O
LL
E G
E A
V E
S
U
IT
E
TY
LE
R
, T E
X A
S
3.
2.
in fo fit zp at ric ka rc hi te ct s.
co m
© 2026
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
1" ACTUAL
3/3/26
JOB NUMBER
SHEET NUMBER
25.102
DATE
TREY GREER
SHEET REVISION HISTORY
PROJECT MANAGER
UT
T
YL
ER
MU
NT
Z
LIB
RA
RY
S
TA
IR
RE
NO
VA
TI
ON
TY
LE
R , T
EX
AS
02/06/2026 ISSUED FOR CONSTRUCTION
E
D
C
B
A
1 2 3 4 5 6
DEMOLITION
PLANS
D101
DN
DN
D5 D101
D5 D101
D5 D101
D5 D101
REMOVE EXISTING GLASS, CHROME
TUBE & HANDRAIL SYSTEM
REMOVE EXISTING FLOORING & BASE BELOW
STAIR & EXISTING MUD BED @ RECESSED SLAB
EXISTING FLOORING &
BASE TO REMAIN
REMOVE EXISTING FLOORING & BASE &
EXISTING MUD BED @ RECESSED SLAB
REMOVE EXISTING FLOORING & BASE & EXISTING
MUD BED @ 1 1/2" DEEP RECESSED SLAB
REMOVE EXISTING GLASS, CHROME
TUBE & HANDRAIL SYSTEM
REMOVE BRICK TILE FLOORS @STAIR AREAS
REMOVE EXISTING FLOORING & BASE BELOW
STAIR LANDING - PREPARE FOR NEW FLOORING
REMOVE EXISTING FLOORING & BASE &
EXISTING MUD BED @ RECESSED SLAB
REMOVE EXISTING FLOORING & BASE & EXISTING
MUD BED @ 1 1/2" DEEP RECESSED SLAB
PROVIDE PROTECTION
FOR EXISTING CARPET
PAINT UNDERSIDE OF STAIR PT01
EX
IS
TI
NG
F
LO
OR
IN
G
TO
RE
MA
IN
EX
IS
TI
NG
F
LO
OR
IN
G
TO
RE
MA
IN
VIEW 1
VIEW 2
BASE BID: NO WORK
ALTERNATE 1: REMOVE EXISTING FLOORING
& BASE AND PREP FOR NEW FLOOR TILE
EXISTING FLOORING &
BASE TO REMAIN
PROVIDE PROTECTION
FOR EXISTING CARPET
EXISTING FLOORING TO
REMAIN
11/2" 21/2" 11/4"
C U
R B
H T.
- 5 " T
Y P.
REMOVE EXISTING TEMPERED GLASS STAIR
RAILS TYP. FULL HEIGHT GLASS WALLS
@ EA. FLOOR TO REMAIN
REMOVE ALUMINUM CAP TRIM @ STAIR RUNS
REMOVE BRICK PAVER TILE AT TREADS, RISERS, & CURBS
REMOVE 5/8" GYP. BD. & 7/8" CHANNELS AS REQ'D
FOR NEW WORK.
REMOVE EXISTING MORTAR BED AND PREPARE AS REQUIRED FOR
NEW TILE
EXISTING STEEL CURB FRAME @ EVERY 3RD STEP TO
REMAIN
REMOVE EXISTING CHROME PIPE HANDRAILS TYP.
DEMO
FI
E
LD
D
E
TE
R M
IN
E
N
SCALE: 1/4" = 1'-0"
A1 1ST FLOOR DEMOLITION PLAN
D101 0 2' 4' 8'
SCALE: 1 1/2"= 1'-0"
D5 EXISTING GLASS HANDRAIL DEMOLITION SECTION
D101 0 6'' 12'' 18''
VIEW 2
DEMOLITION NOTES
1. REMOVE TILE @ TREADS, RISERS, & CURBS ON ENTIRE STAIR SYSTEM ON ALL LEVELS.
2. REMOVE ALL ALUMINUM ANODIZED METAL CURB CAPS AT
STAIR CURBS.
3. REMOVE ENTIRE EXISTING GLASS HANDRAIL SYSTEM & MOUNTING RAIL ON ALL LEVELS.
4. REMOVE ALL CHROME FINISH RAILS & NEWEL POSTS.
5. REMOVE OTHER MATERIALS & ELEMENTS AS REQUIRED FOR NEW WORK SHOWN.
6. CONSTRUCT TEMPORARY FLOOR TO CEILING BARRIERS AS NEEDED TO MINIMIZE SPREAD OF DUST AND
NOISE DURING DEMO AND CONSTRUCTION
7. PROVIDE TEMPORARY SAFETY RAILINGS TO ENSURE STAIR OPENINGS ARE GUARDED AGAINST PUBLIC
ENTRY
VIEW 1
N . C
O
LL
E G
E A
V E
S
U
IT
E
TY
LE
R
, T E
X A
S
3.
2.
in fo fit zp at ric ka rc hi te ct s.
co m
© 2026
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
1" ACTUAL
3/3/26
JOB NUMBER
SHEET NUMBER
25.102
DATE
TREY GREER
SHEET REVISION HISTORY
PROJECT MANAGER
UT
T
YL
ER
MU
NT
Z
LIB
RA
RY
S
TA
IR
RE
NO
VA
TI
ON
TY
LE
R , T
EX
AS
02/06/2026 ISSUED FOR CONSTRUCTION
E
D
C
B
A
1 2 3 4 5 6
DEMOLITION
PLANS
D102
ELEV
ELEV
DN
DN
DN
UP
D5 D101
D5 D101
D5 D101 C5
A201
REMOVE CHROME TUBE & GLASS
HANDRAIL SYSTEM
REMOVE METAL CURB CAP
@ ALL STAIR RUNS TYPICAL.
EXISTING FULL HEIGHT
GLASS WALLS & CURB TO REMAIN
FULL HEIGHT GLASS WALLS & CURB TO REMAIN
REMOVE BRICK TILE FLOORS @
STAIR AREAS
REMOVE EXISTING FLOORING & BASE & EXISTING
MUD BED @ 1 1/2" DEEP RECESSED SLAB
REMOVE EXISTING FLOORING & BASE & EXISTING
MUD BED @ 1 1/2" DEEP RECESSED SLAB
REMOVE EXISTING FLOORING & BASE & EXISTING
MUD BED @ 1 1/2" DEEP RECESSED SLAB
EXISTING FLOORING &
BASE TO REMAIN
EXISTING FLOORING &
BASE TO REMAIN
EXISTING FLOORING &
BASE TO REMAIN
REMOVE CHROME TUBE & GLASS
HANDRAIL SYSTEM
REMOVE BRICK TILE FLOORS
@ STAIR AREAS
REMOVE CHROME TUBE & GLASS
HANDRAIL SYSTEM
REMOVE CHROME TUBE & GLASS
HANDRAIL SYSTEM
FULL HEIGHT GLASS WALLS & CURB TO REMAIN
FULL HEIGHT GLASS WALLS & CURB TO REMAIN
REMOVE MODULAR FURNITURE TO
DEMO FLOORING BENEATH
CLEAN WAX FROM EXISTING BRICK WALLS
PAINT UNDERSIDE OF STAIR PT01
1ST FLOOR
BELOW
TO 3RD
FLOOR
VIEW 3
EX
IS
TI
NG
F
LO
OR
IN
G
TO
RE
MA
IN
EXISTING FLOORING TO
REMAIN
EXISTING FLOORING TO
REMAIN
VIEW 4
EX
IS
TI
NG
F
LO
OR
IN
G
TO
RE
MA
IN
C5 A201
N
SCALE: 1/4" = 1'-0"
A1 2ND FLOOR DEMOLITION PLAN
D102 0 2' 4' 8'
VIEW 3 VIEW 4
DEMOLITION NOTES
1. REMOVE TILE @ TREADS, RISERS, & CURBS ON ENTIRE STAIR SYSTEM ON ALL LEVELS.
2. REMOVE ALL ALUMINUM ANODIZED METAL CURB CAPS AT
STAIR CURBS.
3. REMOVE ENTIRE EXISTING GLASS HANDRAIL SYSTEM & MOUNTING RAIL ON ALL LEVELS.
4. REMOVE ALL CHROME FINISH RAILS & NEWEL POSTS.
5. REMOVE OTHER MATERIALS & ELEMENTS AS REQUIRED FOR NEW WORK SHOWN.
6. CONSTRUCT TEMPORARY FLOOR TO CEILING BARRIERS AS NEEDED TO MINIMIZE SPREAD OF DUST AND
NOISE DURING DEMO & CONSTRUCTION.
7. PROVIDE TEMPORARY SAFETY RAILINGS TO ENSURE STAIR OPENINGS ARE GUARDED AGAINST PUBLIC
N . C
O
LL
E G
E A
V E
S
U
IT
E
TY
LE
R
, T E
X A
S
3.
2.
in fo fit zp at ric ka rc hi te ct s.
co m
© 2026
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
1" ACTUAL
3/3/26
JOB NUMBER
SHEET NUMBER
25.102
DATE
TREY GREER
SHEET REVISION HISTORY
PROJECT MANAGER
UT
T
YL
ER
MU
NT
Z
LIB
RA
RY
S
TA
IR
RE
NO
VA
TI
ON
TY
LE
R , T
EX
AS
02/06/2026 ISSUED FOR CONSTRUCTION
E
D
C
B
A
1 2 3 4 5 6
DEMOLITION
PLANS
D103
ELEV
ELEV
DN
DN
CURB @ 3RD
FLOOR BELOW
REMOVE EXISTING FLOORING & BASE &
EXISTING MUD BED @ 1 1/2" DEEP
RECESSED SLAB
REMOVE EXISTING
FLOORING & BASE
PREP FOR NEW
FLOORING & BASE
REMOVE CHROME TUBE & GLASS
GUARDRAIL SYSTEM & CURB
REMOVE BRICK TILE FLOORS @
STAIR AREAS
REMOVE EXISTING FLOORING & BASE
& EXISTING MUD BED @ RECESSED
SLAB
REMOVE CHROME TUBE & GLASS
GUARDRAIL SYSTEM & CURB
REMOVE EXISTING FLOORING & BASE &
EXISTING MUD BED @ RECESSED SLAB
EXISTING WALLS
EXISTING WALLS
REMOVE EXISTING FLOORING &
BASE & EXISTING MUD BED @
RECESSED SLAB
REMOVE CHROME TUBE & GLASS
HANDRAIL SYSTEM
3rd FLOOR
BELOW
REMOVE GUARDRAIL & CURB CAP TYP.
EX
IS
TI
NG
F
LO
OR
IN
G
TO
RE
MA
IN
EX
IS
TI
NG
F
LO
OR
IN
G
TO
RE
MA
IN
REMOVE CHROME TUBE & GLASS GUARDRAIL
SYSTEM & CURB
4TH FLOOR
DOWN TO 3RD
FLOOR
BELOW
VIEW 5
D5 D101
D5 D101
ELEV
ELEV
UP
DN
DN
REMOVE EXISTING CHROME
HANDRAILS & NEWELS AT
ALL FLOORS & LANDINGS
REMOVE EXISTING FLOORING AND
PREP FOR NEW FLOORING
REMOVE EXISTING FLOORING & BASE &
EXISTING MUD BED @ 1 1/2" DEEP
RECESSED SLAB
REMOVE CHROME TUBE & GLASS
GUARDRAIL SYSTEM & CURB
REMOVE CHROME TUBE & GLASS
HANDRAIL SYSTEM
REMOVE CHROME TUBE & GLASS
GUARDRAIL SYSTEM & CURB
REMOVE CHROME TUBE & GLASS
GUARDRAIL SYSTEM & CURB
REMOVE CHROME TUBE & GLASS
HANDRAIL SYSTEM
REMOVE BRICK TILE FLOORS @ STAIR
AREAS
REMOVE CHROME TUBE & GLASS
GUARDRAIL SYSTEM & CURB
PAINT UNDERSIDE OF STAIR PT01
UP TO 4TH
FLOOR ABOVE
DOWN TO 2ND
FLOOR
BELOW
3RD FLOOREX
IS
TI
NG
F
LO
OR
IN
G
TO
RE
MA
IN
EX
IS
TI
NG
F
LO
OR
IN
G
TO
RE
MA
IN
VIEW 4
D5 D101
D5 D101
REMOVE BRONZE METAL CURB
CAP @ ALL FLOORS TYPICAL.
N N
SCALE: 1/4" = 1'-0"
A3 4TH FLOOR DEMOLITION PLAN
D103 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
A1 3RD FLOOR DEMOLITION PLAN
D103 0 2' 4' 8'
VIEW 4
VIEW 5
DEMOLITION NOTES
1. REMOVE TILE @ TREADS, RISERS, & CURBS ON ENTIRE STAIR SYSTEM ON ALL LEVELS.
2. REMOVE ALL ALUMINUM ANODIZED METAL CURB CAPS AT
STAIR CURBS.
3. REMOVE ENTIRE EXISTING GLASS HANDRAIL SYSTEM & MOUNTING RAIL ON ALL LEVELS.
4. REMOVE ALL CHROME FINISH RAILS & NEWEL POSTS.
5. REMOVE OTHER MATERIALS & ELEMENTS AS REQUIRED FOR NEW WORK SHOWN.
6. CONSTRUCT TEMPORARY FLOOR TO CEILING BARRIERS AS NEEDED TO MINIMIZE SPREAD OF DUST AND
NOISE DURING DEMO & CONSTRUCTION.
7. PROVIDE TEMPORARY SAFETY RAILINGS TO ENSURE STAIR OPENINGS ARE GUARDED AGAINST PUBLIC
N . C
O
LL
E G
E A
V E
S
U
IT
E
TY
LE
R
, T E
X A
S
3.
2.
in fo fit zp at ric ka rc hi te ct s.
co m
© 2026
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
1" ACTUAL
3/3/26
JOB NUMBER
SHEET NUMBER
25.102
DATE
TREY GREER
SHEET REVISION HISTORY
PROJECT MANAGER
UT
T
YL
ER
MU
NT
Z
LIB
RA
RY
S
TA
IR
RE
NO
VA
TI
ON
TY
LE
R , T
EX
AS
02/06/2026 ISSUED FOR CONSTRUCTION
E
D
C
B
A
1 2 3 4 5 6
FLOOR PLANS
A101
DN
DN
C5 A201
CONTINUE FLOOR FINISH PATTERN UNDER STAIR & LANDING
PT01 PT01
PT01 PT
NEW GLASS
GUARDRAIL/HANDRAIL
SYSTEM
NEW GLASS GUARDRAIL/
HANDRAIL SYSTEM
CT
CT02
CT
CT02
TERMINATE VERTICAL CURB
FACE TO FLOOR
INSTALL NEW MUD BED IN EXISTING
SLAB RECESS TO BE FLUSH W/
ADJACENT SLAB SURFACE
PAINT UNDERSIDE OF STAIR PT01
W:
B:
F:
PT01
CT02
CT01
F: RF01
F: RF01
B: RB01
B: RB01
B:
F:
RB01
CP01
C5 A201
NEW GLASS
GUARDRAIL/
HANDRAIL SYSTEM
BASE BID: NO WORK
ALTERNATE 1: REPLACE EXISTING
FLOOR WITH CT01 & BASE WITH CT02.
MARK MANUFACTURER STYLE COLOR SIZE/SPECS REMARKS
CP01 MILLIKEN OBEX CUTX/FIZZ 133 TAUPE 50CM x 50CM, MONOLITHIC INSTALLATIONWALKOFF CARPET
RF01 INTERFACE LEVEL SET NATURAL WOODGRAINS WASHED MAPLE 4.5MM, ASHLAR INSTALLATION MAIN FLOOR BASE BID
CT01 DALTILE REMINISCENT AGED BEIGE 12" x 24" STAIR TILE, FLOOR TILE AT ALTERNATES
CT02 DALTILE REMINISCENT AGED BEIGE 3" x 12" TILE BASE
RB01 TARKETT-JOHNSONITE DURACOVE THERMOPLASTIC RUBBER BASE GREY HAZE 4"
BASE USED AT ALL AREAS WHERE NEW FLOORING (LVT
OR CARPET) TOUCHES WALLS
PT01 BENJAMIN MOORE EGGSHELL OC-22 CALM 2111-70
T01 SCHLUTER RENO - U, SCHIENE SATIN ANODIZED
METAL TRANSITION STRIP BETWEEN FLOORING CHANGES
WITH HEIGHT DIFFERENCES
T02 SCHLUTER TREP-E SATIN ANODIZED METAL STAIR NOSING AT ALL NEW TILE STAIRS
SF01 LATICRETE SPECTRALOCK PRO PREMIUM GROUT 27 HEMP GROUT AT TILE
SPECIAL FINISH
TRANSITION STRIP
PAINT
LEGEND
CARPET
CERAMIC TILE
RUBBER BASE
RESILIENT FLOORING
N
SCALE: 1/4" = 1'-0"
A1 1ST FLOOR PLAN
A101 0 2' 4' 8'
GENERAL NOTES:
SCOPE OF PROJECT:
THE PROJECT (BASE BID) INCLUDES NEW TURNKEY STAIR HANDRAIL & GUARDRAIL REPLACEMENT WITH GLASS RAIL SYSTEM (BASIS OF
DESIGN, LIVERS BRONZE STRUCT-U-RAIL).
BASE BID ALSO INCLUDES FULL REPLACEMENT OF TILE FINISH AT ALL LEVELS OF STAIR RUNS & INTERMEDIATE (MID-LEVEL) LANDINGS, INCLUDING TREADS, RISERS, & SIDE CURBS, PREPARATION OF FLOOR SLAB & INSTALLATION OF NEW LVT & COVER BASE THROUGHOUT EXISTING TILE AREAS OF EACH FLOOR LEVEL; PAINTING OF WALLS, CURBS, AND UNDERSIDE OF STAIR.
ALTERNATES INCLUDE CERAMIC TILE FLOORING IN VARIOUS AREAS - SEE DRAWINGS
1. NOT ALL RAILING CONDITIONS ARE SHOWN IN DETAIL. CONTRACTOR TO LAY OUT & DETAIL FULL SET OF NEW RAIL CONDITIONS, ELEMENTS, & DETAILS FOR SHOP DRAWING REVIEW & APPROVAL.
2. LAYOUT & DIMENSIONS ARE APPROXIMATELY SHOWN BASED ON EXISTING DRAWINGS AND FIELD OBSERVATIONS. CONTRACTOR SHALL
FIELD VERIFY ALL DIMENSIONS PRIOR TO SHOP DRAWING PREPARATION.
3. PREPARE FLOOR SLAB TO RECEIVE NEW FLOORING. INCLUDE FLOATING AS NEEDED. ALL RECESSED SLAB AREAS TO RECEIVE NEW MUD
BED TO MATCH ELEVATION OF ADJACENT SLAB.
4. INSTALL ALL FLOOR FINISH MATERIALS TIGHT TO DRYWALL AND MILLWORK
5. NEW TILE LAYOUT SHALL BE CENTERED.
6. ALL VERTICAL SURFACES WITHIN STAIR SHAFT & UNDERSIDE OF ALL STAIR RUNS TO BE PAINTED PT01.
7. ALL TILE GROUT JOINTS TO BE 1/16" OR SMALLEST GROUT LINE RECOMMENDED BY TILE MANUFACTURER TYP. CONFIRM GROUT LINE
DIMENSIONS FOR ALL TILE WITH ARCH. PRIOR TO INSTALL.
BASE BID FLOORING SCOPE:
ALL FLOORING AND BASE AS SHOWN ON THIS DRAWING
ALTERNATE 1: ALTERNATE 2: ALTERNATE 3:
FIRST FLOOR ONLY SECOND FLOOR ONLY THIRD & FOURTH FLOORS ONLY
FLOOR: CT01 FLOOR: CT01 FLOOR: CT01
BASE: CT02 BASE: CT02 BASE: CT02
-FINISHES @ STAIRS/TREADS/LANDINGS/BASE - NO CHANGE @ ALTERNATES
N . C
O
LL
E G
E A
V E
S
U
IT
E
TY
LE
R
, T E
X A
S
3.
2.
in fo fit zp at ric ka rc hi te ct s.
co m
© 2026
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
1" ACTUAL
3/3/26
JOB NUMBER
SHEET NUMBER
25.102
DATE
TREY GREER
SHEET REVISION HISTORY
PROJECT MANAGER
UT
T
YL
ER
MU
NT
Z
LIB
RA
RY
S
TA
IR
RE
NO
VA
TI
ON
TY
LE
R , T
EX
AS
02/06/2026 ISSUED FOR CONSTRUCTION
E
D
C
B
A
1 2 3 4 5 6
FLOOR PLANS
A102
ELEV
ELEV
DN
DN
DN
UP
C5 A201
'-7
1/ 4"
'-0
28'-71/2"
EXISTING CURB & FULL HT. GLASS WALL
TO REMAIN AT THIS LOCATION: PROTECT AS REQ'D
NEW GLASS GUARDRAIL/HANDRAIL SYSTEM
EXISTING SOLID WALLS TO REMAIN TYP.
REFINISH ALL ADJACENT WALL FINISHES
TO MATCH AS PART OF STAIR RAIL
PROJECT SCOPE
RAILING SYSTEM
TERMINATES @
GLASS WALL
PT01
PT
PT
PT01
PT
FULL HEIGHT GLASS PARTITIONS TO REMAIN
TYPICAL: PROTECT AS REQUIRED.
FULL HEIGHT GLASS PARTITIONS TO REMAIN
TYPICAL: PROTECT AS REQUIRED.
NEW GLASS GUARDRAIL/HANDRAIL SYSTEM
NEW GLASS GUARDRAIL/HANDRAIL SYSTEM
FULL HEIGHT GLASS PARTITIONS TO REMAIN
TYPICAL: PROTECT AS REQUIRED.
PT01
REMOVE MODULAR FURNITURE AND
CONTINUE NEW FLOORING TO MEET
EXISTING CARPET - MOVE FURNITURE
BACK TO ORIGINAL LOCATION @
COMPLETION OF PROJECT
PT
INSTALL NEW MUD BED IN EXISTING
SLAB RECESS TO BE FLUSH W/
ADJACENT SLAB SURFACE
EXTENT OF MUD BEDCLEAN WAX FROM EXISTING BRICK WALLS
PAINT UNDERSIDE OF STAIR PT01
1ST FLOOR
BELOW
OPEN TO BELOW
TO 3RD
FLOOR
W:
B:
F:
PT01
CT02
CT01
W:
B:
F:
PT01
CT02
CT01
F: RF01F: RF01
F: RF01
B: RB01
B: RB01
B: RB01
B:
F:
RB01
CP01
C5 A201
N
SCALE: 1/4" = 1'-0"
A1 2ND FLOOR PLAN
A102 0 2' 4' 8'
GENERAL NOTES:
SCOPE OF PROJECT:
THE PROJECT (BASE BID) INCLUDES NEW TURNKEY STAIR HANDRAIL & GUARDRAIL REPLACEMENT WITH GLASS RAIL SYSTEM (BASIS OF
DESIGN, LIVERS BRONZE STRUCT-U-RAIL).
BASE BID ALSO INCLUDES FULL REPLACEMENT OF TILE FINISH AT ALL LEVELS OF STAIR RUNS & INTERMEDIATE (MID-LEVEL) LANDINGS, INCLUDING TREADS, RISERS, & SIDE CURBS, PREPARATION OF FLOOR SLAB & INSTALLATION OF NEW LVT & COVER BASE THROUGHOUT EXISTING TILE AREAS OF EACH FLOOR LEVEL; PAINTING OF WALLS, CURBS, AND UNDERSIDE OF STAIR.
ALTERNATES INCLUDE CERAMIC TILE FLOORING IN VARIOUS AREAS - SEE DRAWINGS
1. NOT ALL RAILING CONDITIONS ARE SHOWN IN DETAIL. CONTRACTOR TO LAY OUT & DETAIL FULL SET OF NEW RAIL CONDITIONS, ELEMENTS, & DETAILS FOR SHOP DRAWING REVIEW & APPROVAL.
2. LAYOUT & DIMENSIONS ARE APPROXIMATELY SHOWN BASED ON EXISTING DRAWINGS AND FIELD OBSERVATIONS. CONTRACTOR SHALL
FIELD VERIFY ALL DIMENSIONS PRIOR TO SHOP DRAWING PREPARATION.
3. PREPARE FLOOR SLAB TO RECEIVE NEW FLOORING. INCLUDE FLOATING AS NEEDED. ALL RECESSED SLAB AREAS TO RECEIVE NEW MUD
BED TO MATCH ELEVATION OF ADJACENT SLAB.
4. INSTALL ALL FLOOR FINISH MATERIALS TIGHT TO DRYWALL AND MILLWORK
5. NEW TILE LAYOUT SHALL BE CENTERED.
6. ALL VERTICAL SURFACES WITHIN STAIR SHAFT & UNDERSIDE OF ALL STAIR RUNS TO BE PAINTED PT01.
7. ALL TILE GROUT JOINTS TO BE 1/16" OR SMALLEST GROUT LINE RECOMMENDED BY TILE MANUFACTURER TYP. CONFIRM GROUT LINE
DIMENSIONS FOR ALL TILE WITH ARCH. PRIOR TO INSTALL.
BASE BID FLOORING SCOPE:
ALL FLOORING AND BASE AS SHOWN ON THIS DRAWING
ALTERNATE 1: ALTERNATE 2: ALTERNATE 3:
FIRST FLOOR ONLY SECOND FLOOR ONLY THIRD & FOURTH FLOORS ONLY
FLOOR: CT01 FLOOR: CT01 FLOOR: CT01
N . C
O
LL
E G
E A
V E
S
U
IT
E
TY
LE
R
, T E
X A
S
3.
2.
in fo fit zp at ric ka rc hi te ct s.
co m
© 2026
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
1" ACTUAL
3/3/26
JOB NUMBER
SHEET NUMBER
25.102
DATE
TREY GREER
SHEET REVISION HISTORY
PROJECT MANAGER
UT
T
YL
ER
MU
NT
Z
LIB
RA
RY
S
TA
IR
RE
NO
VA
TI
ON
TY
LE
R , T
EX
AS
02/06/2026 ISSUED FOR CONSTRUCTION
E
D
C
B
A
1 2 3 4 5 6
FLOOR PLANS
A103
ELEV
ELEV
UP
DN
DN
'-5
1/ 2"
'-7
3/ 8"
33'-4"
16'-53/4"
5" VERTICAL
CURB FACE
15" X 15" GYP. BD.
COL. @ 3RD LEVEL
CURB RETURN
@ 3RD FLOORNEW HANDRAILS &
GUARDRAILS
TYPICAL
NEW GLASS GUARDRAIL/
HANDRAIL SYSTEM
MOUNT HANDRAIL TO WALL
WHERE IT EXTENDS BELOW
GLASS GUARDRAIL - PROVIDE
BLOCKING AS NECESSARY
NEW GLASS GUARDRAIL
SYSTEM AROUND STAIR
OPENING
NEW GLASS GUARDRAIL SYSTEM
AROUND STAIR OPENING
MOUNT HANDRAIL TO WALL
WHERE IT EXTENDS BELOW
GLASS GUARDRAIL - PROVIDE
BLOCKING AS NECESSARY
PT
PT
PT01
PT01
PT01
CT02
PT
CT
PT
CT
PT
CT
PT
CT
EXTENT OF MUD BED
INSTALL NEW MUD BED IN EXISTING
SLAB RECESS TO BE FLUSH W/
ADJACENT SLAB SURFACE
PT
PT
PT
01 PT
EXISTING FLOORING TO REMAIN
EXISTING FLOORING TO REMAIN
PT01
PAINT UNDERSIDE OF STAIR PT01
UP TO 4TH
FLOOR ABOVE
DOWN TO 2ND
FLOOR
BELOW
3RD FLOOR STAIR & LOBBY PLAN
3RD FLOOR
F: CT01
F: RF01
SIM SIM
B: RB01
B: RB01
W:
B:
F:
PT01
CT02
CT01
C5 A201
C5 A201
ELEV
ELEV
DN
DN
2'-0" 16'-5" 2'-0"
32'-0"
30'-51/2"
6' -1
03/ 4"
'-3
5/ 8"
'-4
1/ 2"
CURB @ 3RD
FLOOR BELOW
NEW CURB & GUARDRAIL: PROVIDE GLASS GATE
OF A SIMILAR DESIGN AND LOOK AS THE "STRUCT-
U-RAIL", OUTFITTED WITH HEAVY DUTY HINGES,
HANDLE, AND KEYED LOCKING MECHANISM
NEW S.S.
GUARDRAIL
TYP.
NEW CURB & GLASS GUARDRAIL
SYSTEM TO FILL GAP
MOUNT HANDRAIL TO WALL
WHERE IT EXTENDS BELOW
GLASS GUARDRAIL - PROVIDE
BLOCKING AS NECESSARY
MOUNT HANDRAIL TO WALL
WHERE IT EXTENDS BELOW
GLASS GUARDRAIL - PROVIDE
BLOCKING AS NECESSARY
NEW
HANDRAIL
TYP.
NEW GLASS GUARDRAIL/
HANDRAIL SYSTEM
PT01
CT02
PT
CT
PT
CT
PT
CT
PT
CT
NEW GLASS GUARDRAIL
SYSTEM AROUND STAIR
OPENING
NEW GLASS GUARDRAIL SYSTEM AROUND STAIR OPENING
PT
PT
PT
PT
PT01
PT
PT
PT01
EXTENT OF MUD BED
INSTALL NEW MUD BED IN EXISTING
SLAB RECESS TO BE FLUSH W/
ADJACENT SLAB SURFACE
NEW GLASS GUARDRAIL
SYSTEM AROUND STAIR
OPENING
4TH FLOOR
DOWN TO 3RD
FLOOR
BELOW
W:
B:
F:
PT01
CT02
CT01
F: RF01
F: RF01
F: RF01
SIM SIM
B: RB01
B: RB01
B: RB01
C5 A201
C5 A201
N N
SCALE: 1/4" = 1'-0"
A1 3RD FLOOR PLAN
A103 0 2' 4' 8'
SCALE: 1/4" = 1'-0"
A3 4TH FLOOR PLAN
A103 0 2' 4' 8'
GENERAL NOTES:
SCOPE OF PROJECT:
THE PROJECT (BASE BID) INCLUDES NEW TURNKEY STAIR HANDRAIL & GUARDRAIL REPLACEMENT WITH GLASS RAIL SYSTEM (BASIS OF
DESIGN, LIVERS BRONZE STRUCT-U-RAIL).
BASE BID ALSO INCLUDES FULL REPLACEMENT OF TILE FINISH AT ALL LEVELS OF STAIR RUNS & INTERMEDIATE (MID-LEVEL) LANDINGS, INCLUDING TREADS, RISERS, & SIDE CURBS, PREPARATION OF FLOOR SLAB & INSTALLATION OF NEW LVT & COVER BASE THROUGHOUT EXISTING TILE AREAS OF EACH FLOOR LEVEL; PAINTING OF WALLS, CURBS, AND UNDERSIDE OF STAIR.
ALTERNATES INCLUDE CERAMIC TILE FLOORING IN VARIOUS AREAS - SEE DRAWINGS
1. NOT ALL RAILING CONDITIONS ARE SHOWN IN DETAIL. CONTRACTOR TO LAY OUT & DETAIL FULL SET OF NEW RAIL CONDITIONS, ELEMENTS, & DETAILS FOR SHOP DRAWING REVIEW & APPROVAL.
2. LAYOUT & DIMENSIONS ARE APPROXIMATELY SHOWN BASED ON EXISTING DRAWINGS AND FIELD OBSERVATIONS. CONTRACTOR SHALL
FIELD VERIFY ALL DIMENSIONS PRIOR TO SHOP DRAWING PREPARATION.
3. PREPARE FLOOR SLAB TO RECEIVE NEW FLOORING. INCLUDE FLOATING AS NEEDED. ALL RECESSED SLAB AREAS TO RECEIVE NEW MUD
BED TO MATCH ELEVATION OF ADJACENT SLAB.
4. INSTALL ALL FLOOR FINISH MATERIALS TIGHT TO DRYWALL AND MILLWORK
5. NEW TILE LAYOUT SHALL BE CENTERED.
6. ALL VERTICAL SURFACES WITHIN STAIR SHAFT & UNDERSIDE OF ALL STAIR RUNS TO BE PAINTED PT01.
7. ALL TILE GROUT JOINTS TO BE 1/16" OR SMALLEST GROUT LINE RECOMMENDED BY TILE MANUFACTURER TYP. CONFIRM GROUT LINE
DIMENSIONS FOR ALL TILE WITH ARCH. PRIOR TO INSTALL.
BASE BID FLOORING SCOPE:
ALL FLOORING AND BASE AS SHOWN ON THIS DRAWING
ALTERNATE 1: ALTERNATE 2: ALTERNATE 3:
FIRST FLOOR ONLY SECOND FLOOR ONLY THIRD & FOURTH FLOORS ONLY
FLOOR: CT01 FLOOR: CT01 FLOOR: CT01
N . C
O
LL
E G
E A
V E
S
U
IT
E
TY
LE
R
, T E
X A
S
3.
2.
in fo fit zp at ric ka rc hi te ct s.
co m
© 2026
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
1" ACTUAL
3/3/26
JOB NUMBER
SHEET NUMBER
25.102
DATE
TREY GREER
SHEET REVISION HISTORY
PROJECT MANAGER
UT
T
YL
ER
MU
NT
Z
LIB
RA
RY
S
TA
IR
RE
NO
VA
TI
ON
TY
LE
R , T
EX
AS
02/06/2026 ISSUED FOR CONSTRUCTION
E
D
C
B
A
1 2 3 4 5 6
STAIR & RAIL
DETAILS
A201
IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING HAS BEEN ENLARGED OR REDUCED,
AFFECTING ALL LABELED SCALES.
- 131 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
7. No more than one bowl of a multi-bowl sink shall be required to provide knee and toe clearance complying with 306.
606.3 Height. Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground.
EXCEPTIONS:
1. A lavatory in a toilet or bathing facility for a single occupant accessed only through a private office and not for common use or public use shall not be required to comply with 606.3.
2. In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (735
mm) minimum and 36 inches (915 mm) maximum, shall be permitted where rough-in plumbing permits connections of supply and drain pipes for sinks mounted at the height of 29 inches (735 mm).
606.4 Faucets. Controls for faucets shall comply with 309. Hand-operated metering faucets shall remain open for 10 seconds minimum.
606.5 Exposed Pipes and Surfaces. Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories and sinks
607 Bathtubs
607.1 General. Bathtubs shall comply with 607.
607.2 Clearance. Clearance in front of bathtubs shall extend the length of the bathtub and shall be 30 inches (760 mm) wide minimum. A lavatory complying with 606 shall be permitted at the control end of the clearance. Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches (305 mm) minimum beyond the wall at the head end of the bathtub.
Figure 607.2 Clearance for Bathtubs
607.3 Seat. A permanent seat at the head end of the bathtub or a removable in-tub seat shall be provided. Seats shall comply with 610.
607.4 Grab Bars. Grab bars for bathtubs shall comply with 609 and shall be provided in accordance with 607.4.1 or 607.4.2.
- 132 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
EXCEPTIONS:
1. Grab bars shall not be required to be installed in a bathtub located in a bathing facility for a single occupant accessed only through a private office and not for common use or public use provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 607.4.
2. In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 607.4.
607.4.1 Bathtubs With Permanent Seats. For bathtubs with permanent seats, grab bars shall be provided in accordance with 607.4.1.
607.4.1.1 Back Wall. Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub. Each grab bar shall be installed 15 inches (380 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall.
607.4.1.2 Control End Wall. A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub.
Figure 607.4.1 Grab Bars for Bathtubs with Permanent Seats
607.4.2 Bathtubs Without Permanent Seats. For bathtubs without permanent seats, grab bars shall comply with 607.4.2.
607.4.2.1 Back Wall. Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub. Each grab bar shall be 24 inches (610 mm) long minimum and shall be installed 24 inches (610 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall.
607.4.2.2 Control End Wall. A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub.
607.4.2.3 Head End Wall. A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub.
- 135 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the controls or, where provided, not on the side of the clearance adjacent to the shower seat.
Figure 608.2.2 Standard Roll-In Type Shower Compartment Size and Clearance
608.2.3 Alternate Roll-In Type Shower Compartments. Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides. A 36 inch (915 mm) wide minimum entry shall be provided at one end of the long side of the compartment.
Figure 608.2.3 Alternate Roll-In Type Shower Compartment Size and Clearance
608.3 Grab Bars. Grab bars shall comply with 609 and shall be provided in accordance with 608.3.
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor.
- 133 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
Figure 607.4.2 Grab Bars for Bathtubs with Removable In-Tub Seats
607.5 Controls. Controls, other than drain stoppers, shall be located on an end wall. Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub. Controls shall comply with 309.4.
Figure 607.5 Bathtub Control Location
607.6 Shower Spray Unit and Water. A shower spray unit with a hose 59 inches (1500 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided. The shower spray unit shall have an on/off control with a non-positive shut-off. If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars. Bathtub shower spray units shall deliver water that is 120°F (49°C) maximum.
Advisory 607.6 Shower Spray Unit and Water. Ensure that hand-held shower spray units are capable of delivering water pressure substantially equivalent to fixed shower heads.
607.7 Bathtub Enclosures. Enclosures for bathtubs shall not obstruct controls, faucets, shower and spray units or obstruct transfer from wheelchairs onto bathtub seats or into bathtubs. Enclosures on bathtubs shall not have tracks installed on the rim of the open face of the bathtub.
- 134 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
608 Shower Compartments
608.1 General. Shower compartments shall comply with 608.
Advisory 608.1 General. Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space.
608.2 Size and Clearances for Shower Compartments. Shower compartments shall have sizes and clearances complying with 608.2.
608.2.1 Transfer Type Shower Compartments. Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915 mm) wide minimum entry on the face of the shower compartment. Clearance of 36 inches (915 mm) wide minimum by 48 inches (1220 mm) long minimum measured from the control wall shall be provided.
Figure 608.2.1 Transfer Type Shower Compartment Size and Clearance
608.2.2 Standard Roll-In Type Shower Compartments. Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides and shall have a 60 inches (1525 mm) wide minimum entry on the face of the shower compartment.
608.2.2.1 Clearance. A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment.
- 135 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor.
- 136 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
EXCEPTIONS:
1. Grab bars shall not be required to be installed in a shower located in a bathing facility for a single occupant accessed only through a private office, and not for common use or public use provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 608.3.
2. In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 608.3.
608.3.1 Transfer Type Shower Compartments. In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall.
Figure 608.3.1 Grab Bars for Transfer Type Showers
608.3.2 Standard Roll-In Type Shower Compartments. Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall opposite the seat. Grab bars shall not be provided above the seat. Where a seat is not provided in standard roll-in type shower compartments, grab bars shall be provided on three walls. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls.
Figure 608.3.2 Grab Bars for Standard Roll-In Type Showers
608.3.3 Alternate Roll-In Type Shower Compartments. In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry. Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls.
- 136 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
EXCEPTIONS:
1. Grab bars shall not be required to be installed in a shower located in a bathing facility for a single occupant accessed only through a private office, and not for common use or public use provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 608.3.
2. In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 608.3.
608.3.1 Transfer Type Shower Compartments. In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall.
Figure 608.3.1 Grab Bars for Transfer Type Showers
608.3.2 Standard Roll-In Type Shower Compartments. Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall opposite the seat. Grab bars shall not be provided above the seat. Where a seat is not provided in standard roll-in type shower compartments, grab bars shall be provided on three walls. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls.
Figure 608.3.2 Grab Bars for Standard Roll-In Type Showers
608.3.3 Alternate Roll-In Type Shower Compartments. In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry. Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls.
- 137 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
Figure 608.3.3 Grab Bars for Alternate Roll-In Type Showers
608.4 Seats. A folding or non-folding seat shall be provided in transfer type shower compartments. A folding seat shall be provided in roll-in type showers required in transient lodging guest rooms with mobility features complying with 806.2. Seats shall comply with 610.
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation of seats complying with 608.4.
608.5 Controls. Controls, faucets, and shower spray units shall comply with 309.4.
608.5.1 Transfer Type Shower Compartments. In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965
mm) minimum and 48 inches (1220 mm) maximum above the shower floor and shall be located on the control wall 15 inches (380 mm) maximum from the centerline of the seat toward the shower opening.
Figure 608.5.1 Transfer Type Shower Compartment Control Location
- 137 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
Figure 608.3.3 Grab Bars for Alternate Roll-In Type Showers
608.4 Seats. A folding or non-folding seat shall be provided in transfer type shower compartments. A folding seat shall be provided in roll-in type showers required in transient lodging guest rooms with mobility features complying with 806.2. Seats shall comply with 610.
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation of seats complying with 608.4.
608.5 Controls. Controls, faucets, and shower spray units shall comply with 309.4.
608.5.1 Transfer Type Shower Compartments. In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965
mm) minimum and 48 inches (1220 mm) maximum above the shower floor and shall be located on the control wall 15 inches (380 mm) maximum from the centerline of the seat toward the shower opening.
Figure 608.5.1 Transfer Type Shower Compartment Control Location
- 138 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
608.5.2 Standard Roll-In Type Shower Compartments. In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor. Where a seat is provided, the controls, faucets, and shower spray unit shall be installed on the back wall adjacent to the seat wall and shall be located 27 inches (685 mm) maximum from the seat wall.
Advisory 608.5.2 Standard Roll-in Type Shower Compartments. In standard roll-in type showers without seats, the shower head and operable parts can be located on any of the three walls of the shower without adversely affecting accessibility.
Figure 608.5.2 Standard Roll-In Type Shower Compartment Control Location
608.5.3 Alternate Roll-In Type Shower Compartments. In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor. Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685
mm) maximum from the side wall behind the seat or shall be located on the back wall opposite the seat 15 inches (380 mm) maximum, left or right, of the centerline of the seat. Where a seat is not provided, the controls, faucets, and shower spray unit shall be installed on the side wall farthest from the compartment entry.
- 139 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
Figure 608.5.3 Alternate Roll-In Type Shower Compartment Control Location
608.6 Shower Spray Unit and Water. A shower spray unit with a hose 59 inches (1500 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided. The shower spray unit shall have an on/off control with a non-positive shut-off. If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars. Shower spray units shall deliver water that is 120°F (49°C) maximum.
EXCEPTION: A fixed shower head located at 48 inches (1220 mm) maximum above the shower finish floor shall be permitted instead of a hand-held spray unit in facilities that are not medical care facilities, long-term care facilities, transient lodging guest rooms, or residential dwelling units.
Advisory 608.6 Shower Spray Unit and Water. Ensure that hand-held shower spray units are capable of delivering water pressure substantially equivalent to fixed shower heads.
608.7 Thresholds. Thresholds in roll-in type shower compartments shall be 1/2 inch (13 mm) high maximum in accordance with 303. In transfer type shower compartments, thresholds 1/2 inch (13
mm) high maximum shall be beveled, rounded, or vertical.
EXCEPTION: A threshold 2 inches (51 mm) high maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a 1/2 inch (13 mm) high threshold would disturb the structural reinforcement of the floor slab.
- 141 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
609.4 Position of Grab Bars. Grab bars shall be installed in a horizontal position, 33 inches (840
mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except that at water closets for children's use complying with 604.9, grab bars shall be installed in a horizontal position 18 inches (455 mm) minimum and 27 inches (685 mm) maximum above the finish floor measured to the top of the gripping surface. The height of the lower grab bar on the back wall of a bathtub shall comply with 607.4.1.1 or 607.4.2.1.
609.5 Surface Hazards. Grab bars and any wall or other surfaces adjacent to grab bars shall be free of sharp or abrasive elements and shall have rounded edges.
609.6 Fittings. Grab bars shall not rotate within their fittings.
609.7 Installation. Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space.
609.8 Structural Strength. Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device, or supporting structure.
610 Seats
610.1 General. Seats in bathtubs and shower compartments shall comply with 610.
610.2 Bathtub Seats. The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor. The depth of a removable in-tub seat shall be 15 inches (380 mm) minimum and 16 inches (405 mm) maximum. The seat shall be capable of secure placement. Permanent seats at the head end of the bathtub shall be 15 inches (380 mm) deep minimum and shall extend from the back wall to or beyond the outer edge of the bathtub.
Figure 610.2 Bathtub Seats
- 142 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
610.3 Shower Compartment Seats. Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry. Where a seat is provided in an alternate roll-in type shower compartment, it shall be a folding type, shall be installed on the front wall opposite the back wall, and shall extend from the adjacent side wall to a point within 3 inches (75 mm) of the compartment entry. In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry. The top of the seat shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor. Seats shall comply with 610.3.1 or 610.3.2.
Figure 610.3 Extent of Seat
610.3.1 Rectangular Seats. The rear edge of a rectangular seat shall be 2 1/2 inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall. The side edge of the seat shall be 1 1/2 inches (38 mm) maximum from the adjacent wall.
Figure 610.3.1 Rectangular Shower Seat
- 143 - 2012 Texas Accessibility Standards Ɣ Effective March 15, 2012 Ɣ Texas Department of Licensing and Regulation
610.3.2 L-Shaped Seats. The rear edge of an L-shaped seat shall be 2 1/2 inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall. The rear edge of the "L" portion of the seat shall be 1 1/2 inches (38 mm) maximum from the wall and the front edge shall be 14 inches (355 mm) minimum and 15 inches (380 mm) maximum from the wall. The end of the "L" shall be 22 inches (560 mm) minimum and 23 inches maximum (585 mm) from the main seat wall.
Figure 610.3.2 L-Shaped Shower Seat
610.4 Structural Strength. Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting structure.
611 Washing Machines and Clothes Dryers
611.1 General. Washing machines and clothes dryers shall comply with 611.
611.2 Clear Floor Space. A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance.
611.3 Operable Parts. Operable parts, including doors, lint screens, and detergent and bleach compartments shall comply with 309.
611.4 Height. Top loading machines shall have the door to the laundry…