12-CC Addendum 3 Drawings 2026-09-04.pdf

PDF 909 KB Posted

Attached to
Coblentz Corner Phase 1 Project
Solicitation number
Not on record
Issued by
Clearfield County, Pennsylvania

About this file

This is an Addendum 3 Drawings document for the Coblentz Corner Phase 1 Project, a structural stabilization, exterior envelope, and repairs initiative located at 100 West Front Street, Berwick, Pennsylvania, prepared by UpStreet Architects, Inc. The project scope encompasses new metal roof deck installation with single-ply membrane roofing system, new metal stud framing and exterior wall construction, new aluminum storefront windows and doors, manufactured stone veneer cladding, new concrete sidewalk replacement, roof trusses and structural elements, new metal roof joists, aluminum gutters and downspouts, roof hatches, and chimney repairs with new aluminum caps. The work includes installation of reinforced PVC walking pads for a 100-foot walking path, spray foam insulation for continuous thermal envelope, and comprehensive flashing and waterproofing details throughout the building envelope. Sealed bids were due Tuesday, September 15, 2026, at 1:00 PM via the PennBid website, with a non-mandatory pre-bid conference held Wednesday, August 26, 2026, at 10:30 AM at the project site. All questions were to be submitted through PennBid by 5:00 PM on Tuesday, September 8, 2026.

The project is subject to Pennsylvania State Prevailing Wage Rates, with a required 10 percent Bid Bond and 100 percent Payment and Performance Bonds from the successful contractor. The work is subject to the Build America Buy America Act, Pennsylvania Office of the Budget Domestic Steel Products Procurement Act, and federal MBE/WBE/Section 3 requirements per 24 CFR Part 75. The project must comply with the 2021 Pennsylvania Uniform Construction Code, 2021 International Residential Code, 2021 International Existing Building Code, 2021 International Energy Conservation Code, 2021 International Mechanical Code, 2021 International Plumbing Code, 2020 International Fire Code, and applicable NFPA 70 standards. The documents specify that the roofer must be certified by the roofing manufacturer with inspection reports required for warranty verification, and all contractors must verify field dimensions and conditions before commencing work. The owner reserves the right to accept or reject any or all bids in their best interest.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADJACENT BUILDING

DS

DS

KO

KO

N O

RT

H 1

A401

ROOF PLAN

SCALE: 1/4" = 1'-0" 0 4 8 FT

SLOPE

SLOPE

1. SEE GENERAL ROOF PLAN NOTES ON A001.

2. (DS) INDICATES DOWNSPOUT LOCATIONS.

3. (KO) INDICATES KICK-OUT FLASHING LOCATIONS.

4. MEMBRANE ROOF DESIGN & SLOPES TO BE

VERIFIED BY ROOFING MANUFACTURER. SLOPE

TO BE 1/4":12 min. ROOFER MUST BE CERTIFIED BY

THE ROOFING MANUFACTURER. MANUFACTURER

MUST PROVIDE INSPECTION REPORT FOR

WARRANTY VERIFICATION.

5. INSTALL 36" WIDE REINFORCED PVC WALKING

PADS FOR A 100' WALKING PATH TO BE

DETERMINED IN THE FIELD.

6. CRICKETS ARE CREATED WITH TAPERED

INSULATION TO SLOPE TO DRAIN. ALL ROOF

SURFACES TO SLOPE 1/4" PER FOOT MIN.

7. FLASH PLUMBING VENTS. SEE PLUMBING

DRAWINGS & DETAIL 3/A601.

8. ROOFER IS RESPONSIBLE TO COORDINATE WITH

G.C. AND MECHANICAL SUBCONTRACTOR TO

DETERMINE ALL FIELD PENETRATIONS AND

CURBS REQUIRED.

9. INSTALL NEW METAL ROOF JOISTS. SEE

STRUCTURAL DRAWINGS.

10. WRAP ROOFING OVER PARAPET WALL AND UNDER

COPING OR DRIP EDGE.

GENERAL NOTES FOR THIS SHEET

SLOPE

SLOPE

P2

SLOPE

WALLS BELOW

WALLS BELOW

A321

A321

A321

A322

A323

A322

A322

P1

P1P2

NEW INSULATION AND MEMBRANE ROOFING SYSTEM

ON NEW METAL ROOF DECK .

WRAP ROOFING MEMBRANE OVER PARPAPET.2

NOT USED.3

WRAP NEW MEMBRANE ROOF TO TOP OF PARAPET AND

FLASH TO ADJACENT BUILDING. SEE DETAIL 1/A602.

NOT USED.6

PROVIDE CRICKET AROUND ROOF HATCH AND

CHIMNEY.

ROOF HATCH. SEE DETAIL 7/A601. INSTALL PER

MANUFACTURER'S DETAILS.

NEW ALUMINUM CHIMNEY CAP. SEE DETAIL 2/A601.

NUMBERED NOTES FOR THIS SHEET

EXISTING CHIMNEY TO BE REPAIRED/REPOINTED.

NEW ALUMINUM GUTTER AND DOWNSPOUTS. SEE

DETAIL 3/A601.

CORNICE TYPES:

HIGH PARAPET, SEE WALL SECTION.P1

LOW PARAPET, SEE WALL SECTION.P2

A323

A301

A301

D at e / T im e

Fi le

N am e

541 PHILADELPHIA ST.

INDIANA, PA 15701

PHONE (724)349-3601

911 MENOHER BLVD.

JOHNSTOWN, PA 15905

PHONE (814)539-0224

05/05/26

© 2025 UpStreet Architects, Inc.

245014

PH

A

SE

W

ES

T

FR

O N

T

ST

R

EE

T, BE

RW

IC

K, P

A

C O

B

LE

N

TZ

C O

R N

ER

/2 1/

/2

8/

/0

4/

ROOF PLAN

A401

R

EV

IS

IO

N S

R

EV

D

AT

E D

ES

C

R

IP

TI

O

N O

F R

EV

IS

IO

N

BY sh N o C ha ng e sh N o C ha ng e sh Ad de nd um

R ev is io ns

GENERAL FLOOR PLAN NOTES

GENERAL

1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE

AND INFORM THE ARCHITECT OF ANY DISCREPANCIES.

2. ALL INTERIOR DIMENSIONS GIVEN ARE TO STUD, UNO. ALL EXTERIOR

DIMENSIONS GIVEN ARE TO OUTSIDE OF WALL SHEATHING OR FACE OF

MASONRY, UNO.

FRAMING

1. ALL WOOD IN CONTACT WITH MASONRY OR CONCRETE TO BE PRESSURE

TREATED.

THERMAL & MOISTURE PROTECTION

1. CAULK ALL AREAS OF POSSIBLE WATER PENETRATION WITH SEALANT AND

BACKER ROD SUITABLE FOR APPLICATION.

EXTERIOR ELEVATION NOTES

1. REFER TO DOOR AND WINDOW SCHEDULES FOR TYPE AND STYLE OF UNITS.

2. PAINT EXTERIOR METAL DOORS.

3. NO DISSIMILAR METALS ARE TO BE IN CONTACT WITH ONE ANOTHER.

4. USE HOT DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS.

5. PUTTY ALL NAIL HOLES THAT ARE EXPOSED TO VIEW.

6. EXPOSED FLASHING SHALL BE IN A COLOR TO MATCH THE ADJACENT MATERIAL.

7. SEAL ALL PENETRATIONS THROUGH EXTERIOR SURFACES.

8. ENSURE COMPLETE GROUTING AT ALL FOUNDATION PENETRATIONS.

9. PARGE ALL EXPOSED CONCRETE BLOCK.

10. PROTECT ALL EXTERIOR SURFACES FROM MUD AND DEBRIS. CLEAN

ANY SOILED AREAS THOROUGHLY BEFORE OWNER WILL ACCEPT.

SPECIAL INSPECTIONS: SPECIAL INSPECTIONS SHALL BE PROVIDED IN ACCORDANCE

WITH SECTION 1704 OF THE 2018 INTERNATIONAL BUILDING CODE.

INSTALLATION OF ANCHOR BOLTS IN CONCRETE AND GROUTED MASONRY

REINFORCED CONCRETE AND REINFORCING STEEL PLACEMENT

STRUCTURAL STEEL

INSTALLATION OF EXPANSION AND/OR ADHESIVE ANCHORS IN CONCRETE AND MASONRY

MASONRY CONSTRUCTION INCLUDING BUT NOT LIMITED TO:

1. REINFORCING STEEL PLACEMENT

2. GROUT PLACEMENT

3. HOT AND COLD WEATHER PROTECTION

CODE REQUIREMENTS

APPLICABLE CODES & REGULATIONS

DIAGRAMMATIC BUILDING PLAN - BUILDING INFORMATION (Not To Scale):

FIRE WALL:

2-HOUR RATED

" " INDICATES APPLICABLE CODEAPPLICABLE CODES:

Pennsylvania Uniform Construction Code (UCC):

2021 International Residential Code (IRC):

2021 International Existing Building Code (IEBC): See IEBC Compliance Path

2021 International Energy Conservation Code (IECC):

2021 International Mechanical Code (IMC):

2021 International Plumbing Code (IPC):

2021 International Fire Code (IFC):

2020 NFPA 70, National Electrical Code (NEC):

N/A

2021 International Building Code (IBC):

N/A

N/A

N/A

N/A

1ST FLOOR

BASEMENT FLOOR

FIRE WALL:

2-HOUR RATED

1. PERMIT IS FOR STRUCTURAL STABILIZATION, EXTERIOR ENVELOPE, AND REPAIRS ONLY

D at e / T im e

Fi le

N am e

541 PHILADELPHIA ST.

INDIANA, PA 15701

PHONE (724)349-3601

911 MENOHER BLVD.

JOHNSTOWN, PA 15905

PHONE (814)539-0224

05/05/26

© 2025 UpStreet Architects, Inc.

245014

PH

A

SE

W

ES

T

FR

O N

T

ST

R

EE

T, BE

RW

IC

K, P

A

C O

B

LE

N

TZ

C O

R N

ER

/2 1/

/2

8/

/0

4/

GENERAL

ARCHITECTURAL

NOTES

A001

R

EV

IS

IO

N S

R

EV

D

AT

E D

ES

C

R

IP

TI

O

N O

F R

EV

IS

IO

N

BY sh N o C ha ng e sh N o C ha ng e sh Ad de nd um

R ev is io

PENNSYLVANIA ONE CALL SYSTEM, INC.

Call Before You Dig

811 or 1-800-242-1776 PA Law Requires Three Working Days' Notice

1-800-242-1776

N

L

NNEP

YS

AV

C

SOAI

EN LLAC

ET

NI

M

SY

AL

I D

UOY

OB FE ER

GID

0 20 40 FT

S. MARKET STREET

W. FRONT STREET

REAGANS AVENUE

N. MARKET STREET

ST. CHARLES PARK

E. FRONT STREET

A002

PARTIAL SITE PLAN

SCALE: 1" = 20'

REPLACE EXISTING

SIDEWALK, SEE 2/A002

6" COMPACTED 2A STONE

BASE UNDER SIDEWALK

EXISTING BRICK WALKING

SURFACE TO REMAIN

NEW 4" CONCRETE SIDEWALK

REINFORCED w/ 6x6 - W1.4/W1.4 WWF.

MATCH EXISTING CONTROL

JOINT SCORE PATTERN

SCALE: 3/4" = 1'-0"

A002

SIDEWALK REPLACEMENT DETAIL

NOTE:

EXISTING TREES IN FRONT OF

BUILDING MAY BE TRIMMED

TO FACILITATE WORK. ARCHITECT

WILL PROVIDE DIRECTION FROM

AN ARBORISTS PRIOR TO TRIMMING

N

D at e / T im e

Fi le

N am e

541 PHILADELPHIA ST.

INDIANA, PA 15701

PHONE (724)349-3601

911 MENOHER BLVD.

JOHNSTOWN, PA 15905

PHONE (814)539-0224

05/05/26

© 2025 UpStreet Architects, Inc.

245014

PH

A

SE

W

ES

T

FR

O N

T

ST

R

EE

T, BE

RW

IC

K, P

A

C O

B

LE

N

TZ

C O

R N

ER

/2 1/

/2

8/

/0

4/

SITE PLAN

A002

R

EV

IS

IO

N S

R

EV

D

AT

E D

ES

C

R

IP

TI

O

N O

F R

EV

IS

IO

N

BY sh N o C ha ng e sh N o C ha ng e

DOOR FRAME DETAILS

SCALE: 1 1/2" = 1'-0"

F2

ALUMINUM FRAME

CAULK PERIMETER,

BOTH SIDES

METAL STUDS

BLOCKING

ZIP SHEATHING

PVC PANEL

METAL STUDS

ZIP SHEATHING

PVC PANEL

1x PVC TRIM BOARDS

F3

WEATHERSTRIPPING, PER DOOR MFR.

PRESSURE TREATED 2x ON

INSIDE OF DOOR OPENING,

VERIFY REQUIREMENTS

WITH DOOR MFR. (PAINT)

UPWARD-ACTING SECTIONAL

DOOR, TRACK & HARDWARE

F1

NEW METAL FRAME

CAULK PERIMETER,

BOTH SIDES

EXISTING EXTERIOR

MASONRY WALL

CAULK

DOOR AND FRAME SCHEDULE

DOOR SIZE FRAME HARDWARE (see spec for sets) ELECTRIFIED COMMENTS DOOR

No. Use Type Mat. Finish W x H x T Type Mat. Finish Sidelight Set No. COORDINATION No.

1st FLOOR AREA 101/1 ENTRANCE/CAFE A ALUM PRE S 3'0" x 7'6" x 1 3/4" b,F2 ALUM PRE (2) 2'6" 1 (See Comments) PROVIDE FOR FUTURE ELECTRIC DOOR STRIKE 101/1 101/2 ENTRANCE/CAFE C ALUM PRE S 15'6" x 8'0" x 1 3/4" F3 ALUM PRE (See Comments)

SECTION 08-36-13 SECTIONAL DOORS

PROVIDE OPERATOR AND CONTROLS PER SPECIFICATION 101/2

101/3 STAIR 'A' B IM P S 3'0" x 6'8" x 1 3/4" a,F1 IM P 2 101/3

GENERAL DOOR NOTES

1. ALL DOORS SHALL FIT UNIFORMLY IN FRAMES.

2. ALL DOORS AND HARDWARE SHALL OPERATE FREELY AND PROPERLY.

3. ALL EXTERIOR METAL DOORS AND FRAMES SHALL BE GALVANIZED.

4. ALL EXTERIOR METAL DOOR FRAMES SHALL BE THERMAL BREAK TYPE.

5. ALL EXTERIOR DOORS SHALL HAVE WEATHERSTRIPPING AND THRESHOLDS.

6. ALL THRESHOLDS TO MEET HC REQUIREMENTS, UNLESS NOTED

OTHERWISE. CAULK ALL THRESHOLDS.

7. ALL EXCESS CAULK AND GLAZIERS PUTTY ON DOOR LITES SHALL BE

REMOVED.

8. ALL GLAZING IN EXTERIOR DOORS AND SIDELITES SHALL BE INSULATED

LOW-E SAFETY GLASS.

9. ALL DOOR CLOSERS TO BE SET TO HANDICAPPED COMPLIANT PRESSURE

AND CLOSING SPEEDS.

10. FLASH EXTERIOR DOORS PER "TYPICAL EXTERIOR DOOR FLASHING" DETAIL

ON SHEET A010. C

FRAME TYPES

a b

DOOR TYPES

A B

" m ax A

FF

VISION LITE:

100 sq. in. max

DOOR & FRAME SCHEDULE ABBREVIATIONS

ALUM Aluminum MHO Magnetic Hold Open COMP Composite P Paint ES Electric Strike PC Pull Cord EXIST Existing PR Pair FP/SP Factory Primed/Site Painted PLAM Plastic Laminate FGL Fiberglass PRE Prefinished GL Glass PWPS Push Wall Plate Switch HCW Hollow Core Wood SL Sidelight HM Hollow Metal S Single IF Insulated Fiberglass SCW Solid Core Wood IM Insulated Metal STN Stain KF Key Fob WD Wood M Metal

HEAD FLASHING TAPE

HEAD FLASHING

SEALANT AROUND JAMBS

TYPICAL EXTERIOR DOOR FLASHING AT ZIP SHEATHING

SCALE: NTS

INSTALL ZIP FLASHING TAPE IN THE JAMBS OF

THE ROUGH OPENING. INSTALL SEALANT AS

(3) SEPERATE BEADS IN THE THRESHOLD & 6"

min. UP THE JAMB. INSTALL DOOR PER

MANUFACTURER'S INSTALLATION GUIDANCE &

APPLY SEALANT AT MOLDING / ZIP SHEATHING

INTERSECTION. INSTALL HEAD FLASHING

ABOVE DOOR. INSTALL ZIP FLASHING TAPE

ABOVE DOOR.

JAMB FLASHING TAPE

ZIP SHEATHING

DOOR FRAME

DAM FLASHING AT BASE OF DOOR

ALUMINUM

STOREFRONT

SEE A030 WINDOW

SCHEDULE AND

ELEVATIONS

STEEL DOOR GLAZED OVERHEAD SECTIONAL DOOR

2' -0

/4

D at e / T im e

Fi le

N am e

541 PHILADELPHIA ST.

INDIANA, PA 15701

PHONE (724)349-3601

911 MENOHER BLVD.

JOHNSTOWN, PA 15905

PHONE (814)539-0224

05/05/26

© 2025 UpStreet Architects, Inc.

245014

PH

A

SE

W

ES

T

FR

O N

T

ST

R

EE

T, BE

RW

IC

K, P

A

C O

B

LE

N

TZ

C O

R N

ER

/2 1/

/2

8/

/0

4/

DOOR NOTES

& SCHEDULE

A010

R

EV

IS

IO

N S

R

EV

D

AT

E D

ES

C

R

IP

TI

O

N O

F R

EV

IS

IO

N

BY sh N o C ha ng e sh N o C ha ng e rc p

Ad de nd um

R ev is io ns

SCALE: 1 1/2" = 1'-0

A030

NEW WINDOW SECTION IN EXISTING INFILLED

OPENING

Head

ALUMINUM

STOREFRONT WINDOW

EXISTING MASONRY

WALL CONSTRUCTION

FLASHING

Jamb

EXISTING MASONRY

WALL CONSTRUCTION

SEALANT

MEMBRANE

FLASHING

Sill

SEALANT

ALUMINUM

STOREFRONT WINDOW

SEALANT

Head

Jamb

Sill

SCALE: 1 1/2" = 1'-0

A030

NEW WINDOW SECTION IN NEW

EXTERIOR WALL

BLOCKING

PVC PANELING

SEALANT

3-5/8" METAL STUD

FRAMING @16" O.C.

NEW ALUMINUM

STOREFRONT WINDOW

BLOCKING

PVC PANELING

MEMBRANE FLASHING

SEALANT

3-5/8" METAL STUD

FRAMING @16" O.C.

NEW ALUMINUM

STOREFRONT WINDOW

1/2" SHEATHING

1/2" SHEATHING

PVC WRAPPED BACK

TO WINDOW FRAME

MEMBRANE FLASHING

BLOCKING

PVC PANELING

MEMBRANE FLASHING

AT ENTIRE PERIMETER

OF OPENING AND

UP FACE OF BACK DAM

SEALANT

3-5/8" METAL STUD

FRAMING @16" O.C.

NEW ALUMINUM

STOREFRONT WINDOW

1/2" ZIP SHEATHING

SILL RECEPTOR

BACK-BEDDED INTO

CONTINUOUS SEALANT

SHIMS

SHEET METAL ANGLE

USED TO FORM

BACK DAM AND END DAMS

2x BLOCKING

2x BLOCKING

2x BLOCKINGMEMBRANE FLASHING

AT ENTIRE PERIMETER

OF OPENING AND

UP FACE OF BACK DAM

SILL RECEPTOR

BACK-BEDDED INTO

CONTINUOUS SEALANT

SHEET METAL ANGLE

USED TO FORM

BACK DAM AND END DAMS

MEMBRANE FLASHING

AT ENTIRE PERIMETER

OF OPENING

WINDOW/STOREFRONT SCHEDULE

SAFETY

NO. MANUFACTURER OPERATION COLOR R.O.(W X H) DETAIL GLAZING

S1 STOREFRONT FIXED BLACK 6'-6" x 5'-8" 1/A030 YES S2 STOREFRONT FIXED BLACK 5'-0" x 5'-8" 1/A030 YES

S3STOREFRONT: SEE DOOR SCHEDULE FOR INFORMATION YES

S4 STOREFRONT FIXED BLACK 5'-4" x 7'-1" 2/A030 YES

GENERAL WINDOW NOTES

1. SAFETY GLAZING (TEMPERED GLASS) SHALL BE PROVIDED IN ALL WINDOWS

CONSIDERED BY THE IRC (OR IBC) TO BE IN A HAZARDOUS LOCATION.

2. STRICTLY COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS.

3. INSTALL NON-EXPANDING SPRAY TYPE FOAM URETHANE INSULATION IN SHIM

SPACE AROUND PERIMETER OF EXTERIOR WINDOWS.

4. SEAL AROUND EXTERIOR PERIMETER OF WINDOW AFTER EXTERIOR WALL

FINISH IS APPLIED.

5. REFER TO EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION.

STOREFRONT TYPES

S1 S2

S3

SEE DOOR SCHEDULE

FOR DOOR INFORMATION

6'-6"

2" 3'-0" 2" 3'-0" 2" 5'-0"

2" 2'-3" 2"2'-3" 2"

5' -8

2" 5'

-4

2"

5' -8

2" 5'

-4

2"

1st FLOOR

2' -3

2' -3

2' -0

/4

S4

8'-2 5/8" 5'-0"

7' -1

7' -6

D at e / T im e

Fi le

N am e

541 PHILADELPHIA ST.

INDIANA, PA 15701

PHONE (724)349-3601

911 MENOHER BLVD.

JOHNSTOWN, PA 15905

PHONE (814)539-0224

05/05/26

© 2025 UpStreet Architects, Inc.

245014

PH

A

SE

W

ES

T

FR

O N

T

ST

R

EE

T, BE

RW

IC

K, P

A

C O

B

LE

N

TZ

C O

R N

ER

/2 1/

/2

8/

/0

4/

A030

WINDOW NOTES

& SCHEDULE

R

EV

IS

IO

N S

R

EV

D

AT

E D

ES

C

R

IP

TI

O

N O

F R

EV

IS

IO

N

BY sh N o C ha ng e sh N o C ha ng e rc p

Ad de nd um

R ev is io

D CH CL B A'

D CH CL B A'

D CH CL B A'

6" OUTRIGGER FRAMING

AND 1/2" SHEATHING, TYP.

1" BLOCKING AND 1/2"

SHEATHING, TYP.

1/2" PAD-OUT

SHEATHING, TYP.

S4

S1 S1

S3 S3

A201

SOUTH ELEVATION

SCALE: 1/4" = 1'-0" 0 2 4 FT

A201

NORTH ELEVATION

SCALE: 1/4" = 1'-0" 0 2 4 FT

BASEMENT

T/ PARAPET

1st FLOOR

'-6

'-4

T/ PARAPET

'-4

TRUSS BRG.

'-0

BASEMENT

T/ PARAPET

1st FLOOR

'-6

'-4

T/ PARAPET

'-4

TRUSS BRG.

'-0

A321

A321

A321

A323

NUMBERED NOTES FOR ELEVATIONS

NOTE: NOT ALL NOTES MAY APPLY TO THIS SHEET

ALUMINUM FASCIA, DRIP EDGE, AND GUTTER.

NEW DOWNSPOUT.2

PATCH AND PAINT EXISTING MASONRY WALL.3

"COBLENTZ CORNER" SIGN TO BE STUD MOUNTED

DIMENSIONAL LETTERS. PROVIDE BLOCKING TO

MOUNT LETTERS.

PROVIDE BLOCKING FOR FUTURE AWNINGS5

INFILL DOOR OPENING WITH NEW STOREFRONT

WINDOW

NEW PIERS AND FOOTINGS, SEE STRUCTURAL

DRAWINGS.

MANUFACTURED STONE VENEER, PARGE MIN. 4" GAP

BETWEEN VENEER AND SIDEWALK.

NEW CHIMNEY CAP, SEE 2/A601.9

A201

HORIZONTAL SECTIONS - SEE 3/A202

SCALE: 1/4" = 1'-0" 0 2 4 ft

GENERAL NOTES FOR THIS SHEET

1. (DS) INDICATES DOWNSPOUT LOCATIONS.

2. ALL TRIM TO BE PAINTED.

3. PROVIDE MOCK-UP FOR APPROVAL.

4. COLORS WILL BE SELECTED.

17'-9 3/4"18'-7 1/4"18'-7 3/4"

5 5 5

7 7

A201

A201

A201

8"8"8"8"8"

EXISTING BUILDING FOUNDATION

M3 M3

PVC SHEET W/ PERIMETER

TRIMBOARDS ON M! COVE, TYP.

PVC SHEET W/ PERIMETER

TRIMBOARDS ON M! COVE, TYP.

EXISTING

DRAIN BOOT EXISTING

DRAIN BOOT

1/

2"

M3M3 M3 M3M3M3M3

CL4

A201

ENLARGED HORIZONTAL SECTION - 3

SCALE: 1/2" = 1'-0" 0 1 2 ft

A201

ENLARGED HORIZONTAL SECTION - 2

SCALE: 1/2" = 1'-0" 0 1 2 ft

A201

ENLARGED HORIZONTAL SECTION - 1

SCALE: 1/2" = 1'-0" 0 1 2 ft

CL

CL

6" OUTRIGGER FRAMING

AND 1/2" SHEATHING, TYP.

1" BLOCKING AND

1/2" SHEATHING, TYP.

1/2" PAD OUT

SHEATHING, TYP.

NOTE: SEE A202 FOR MORE INFORMATION

D at e / T im e

Fi le

N am e

541 PHILADELPHIA ST.

INDIANA, PA 15701

PHONE (724)349-3601

911 MENOHER BLVD.

JOHNSTOWN, PA 15905

PHONE (814)539-0224

05/05/26

© 2025 UpStreet Architects, Inc.

245014

PH

A

SE

W

ES

T

FR

O N

T

ST

R

EE

T, BE

RW

IC

K, P

A

C O

B

LE

N

TZ

C O

R N

ER

/2 1/

/2

8/

/0

4/

ELEVATIONS

A201

R

EV

IS

IO

N S

R

EV

D

AT

E D

ES

C

R

IP

TI

O

N O

F R

EV

IS

IO

N

BY sh N o C ha ng e sh N o C ha ng e rc p

Ad de nd um

R ev is io

3 3 3 3 3

NEW MASONRY CONSTRUCTION NEW METAL STUD CONSTRUCTION

DS

1/

2"

A202

POLYURETHANE MOULDING PROFILES

SCALE: 1/2" = 1'-0" 0 1 2 ft

M1 M2 M3 M4

A202

ENLARGED HORIZONTAL SECTION - 3

SCALE: 1/2" = 1'-0" 0 1 2 ft

A202

ENLARGED HORIZONTAL SECTION - 2

SCALE: 1/2" = 1'-0" 0 1 2 ft

A202

ENLARGED HORIZONTAL SECTION - 1

SCALE: 1/2" = 1'-0" 0 1 2 ft

A202

ENLARGED HORIZONTAL SECTION - 3

SCALE: 1/2" = 1'-0" 0 1 2 ft

A202

ENLARGED HORIZONTAL SECTION - 2

SCALE: 1/2" = 1'-0" 0 1 2 ft

A202

ENLARGED HORIZONTAL SECTION - 1

SCALE: 1/2" = 1'-0" 0 1 2 ft

6" OUTRIGGER FRAMING

AND 1/2" SHEATHING, TYP.

1" BLOCKING AND 1/2"

SHEATHING, TYP.

1/2" PAD OUT

SHEATHING, TYP.

TRIM RETURN, TYP.

3-1/2" TRIM, TYP.

PVC PANEL, TYP.

M1, TYP.

FYPON:

MLD603-8

QUARTER

ROUND

COVE

FYPON:

MLD628-8

WINDOW STOOL

FYPON:

MLD710-10

CORBELL

FYPON:

MLD13-12

M5

DENTIL

FYPON:

MLD434-16

A202

COLUMN TYPES

SCALE: 3/8" = 1'-0" 0 1 2 3 ft

5' -3

/4

A B CL CH C D

4'-9 1/4"

4'-6"

4'-3"

4'-0"

5'-0 1/4"

4'-0"2'-0"

2'-0"

2'-0"

2'-0"

2'-3"

2'-4 1/2"

2'-6"

2'-8"

4'-6"

4'-3"

4'-0"

4'-0"

4'-9 1/4"

4'-6"

4'-3"

4'-0"

4'-0"

5'-0 1/4"

2'-4 1/2"

2'-4 1/2"

2'-7 1/2"

2'-10 1/2"

3'-1 1/2"

3'-4 1/2"

9" 9"

5' -3

/4

9"

9"

5' -3

/4

9"

9"

5' -3

/4

9"

9"

5' -3

/4

9"

5' -3

/4

9"

9"

5' -5

/4

2' -5

/4

5' -5

/4

2' -5

/4

M1

M2 M3

M4

M2

M4

M4

M4

M1

M1

M1

M1

M2 M3

M4

M2

M4

M4

M4

M1

M1

M1

M1

M2 M3

M4

M2

M4

M4

M4

M1

M1

M1

M1

M2 M3

M4

M2

M4

M4

M4

M1

M1

M1

M1 M4

M2

M1

M2 M3

M4

M2

M4

M4

M4

M1

M1

M1

1' -7

/2

COPING

M5

5 1/2" CORNER TRIM

PVC SHEET, TYP.

1' -7

/2

COPING

M5

9 1/2" CORNER

TRIM

COPING

M5

1' -7

PVC SHEET BEHIND

3-1/2" VERTICAL TRIM W/

1-1/2" GAP BETWEEN

BOARDS, TYP.

9 1/2" CORNER

TRIM

COPING

1' -7

" M5

5 1/2" CORNER TRIM

NOTES:

1. ALL PANEL PERIMETER TRIM

TO BE 3-1/2" U.N.O.

2. ALL RECESSED PANEL AREAS

ARE PVC SHEET INSTALLED

W/TRIM OVERLAP AND SOLID

BLOCKING BEHIND.

PVC SHEET,

TYP.

M2 M3

S2 S2 S2 S2 S2 S2 S2 S2

A202

EAST ELEVATION

SCALE: 1/4" = 1'-0" 0 2 4 FT

BASEMENT

T/ PARAPET

1st FLOOR

'-6

'-4

T/ PARAPET

'-4

TRUSS BRG.

'-0

A322

A322

A322

GENERAL NOTES FOR THIS SHEET

1. (DS) INDICATES DOWNSPOUT LOCATIONS.

2. ALL TRIM TO BE PAINTED.

3. PROVIDE MOCK-UP FOR APPROVAL.

4. COLORS WILL BE SELECTED.

A202

HORIZONTAL SECTIONS - SEE 3/A202

SCALE: 1/4" = 1'-0" 0 2 4 FT

NUMBERED NOTES FOR ELEVATIONS

NOTE: NOT ALL NOTES MAY APPLY TO THIS SHEET

ALUMINUM FASCIA, DRIP EDGE, AND GUTTER.

NEW DOWNSPOUT.2

PATCH AND PAINT EXISTING MASONRY WALL.3

"COBLENTZ CORNER" SIGN TO BE STUD MOUNTED

DIMENSIONAL LETTERS. PROVIDE BLOCKING TO

MOUNT LETTERS.

PROVIDE BLOCKING FOR FUTURE AWNINGS5

INFILL DOOR OPENING WITH NEW STOREFRONT

WINDOW

NEW PIERS AND FOOTINGS, SEE STRUCTURAL

DRAWINGS.

MANUFACTURED STONE VENEER, PARGE MIN. 4" GAP

BETWEEN VENEER AND SIDEWALK.

NEW CHIMNEY CAP, SEE 2/A601.9

16'-0" 16'-0" 16'-0"14'-9 3/4" 15'-2 1/4"

55555

A202

A202

A202

A202

A202

A202

A B C B CL B CH B C B D

A B C B CL B CH B C B D

A B C B CL B CH B C B D

PVC SHEET W/ PERIMETER TRIM

BOARDS AND M1 COVE, TYP.

8"8"8"8"8"8"8"8"8"8"

M3 M3 M3 M3 M3 M3 M3 M3 M3 M3

4" MIN.

6" OUTRIGGER FRAMING

AND 1/2" SHEATHING, TYP.

1" BLOCKING AND 1/2"

SHEATHING, TYP.

1/2" PAD-OUT

SHEATHING, TYP.

M3 M3 M3 M3 M3 M3 M3 M3 M3 M3 M3

D at e / T im e

Fi le

N am e

541 PHILADELPHIA ST.

INDIANA, PA 15701

PHONE (724)349-3601

911 MENOHER BLVD.

JOHNSTOWN, PA 15905

PHONE (814)539-0224

05/05/26

© 2025 UpStreet Architects, Inc.

245014

PH

A

SE

W

ES

T

FR

O N

T

ST

R

EE

T, BE

RW

IC

K, P

A

C O

B

LE

N

TZ

C O

R N

ER

/2 1/

/2

8/

/0

4/

ELEVATIONS

A202

R

EV

IS

IO

N S

R

EV

D

AT

E D

ES

C

R

IP

TI

O

N O

F R

EV

IS

IO

N

BY sh N o C ha ng e sh N o C ha ng e rc p

Ad de nd um

R ev is io

3 3 3 3 3 3 3 3 3 3 3

SPRAY FOAM INSULATION

FOR CONTINUOUS THERMAL

ENVELOPE

SLOPE SLOPE

EXISTING CMU

TO REMAIN

EXISTING CMU

TO REMAIN

EXISTING CMU

TO REMAIN

EXISTING CONCRETE

LEDGE

EXISTING CONCRETE

LEDGE

EXISTING CONCRETE

LEDGE

EXISTING PURLINS

& BEAMS

EXISTING PURLINS

& BEAMS

EXISTING PURLINS

& BEAMS

SPRAY FOAM INSULATION

FOR CONTINUOUS THERMAL

ENVELOPE

A321

WALL SECTION THRU GARAGE DOOR @ FRONT STREET

SCALE: 1/2" = 1'-0" 0 1 2 FT

A321

WALL SECTION THRU FRONT DOOR @ FRONT STREET

SCALE: 1/2" = 1'-0" 0 1 2 FT

A321

WALL SECTION THRU WINDOW @ FRONT STREET

SCALE: 1/2" = 1'-0" 0 1 2 FT

1/2" ZIP SHEATHING

3-5/8" METAL STUD FRAMING

@ 16" O.C.

STUD MOUNTED

DIMENSIONAL LETTERS

2" RIGID NSULATION

ALUMINUM STOREFRONT

DOOR FRAME

ALUMINUM DRIP EDGE

SINGLE PLY MEMBRANE

ROOFING, WRAP OVER

PARAPET

1/2" ZIP SHEATHING

3 5/8" METAL STUD

FRAMING @ 16" O.C.

3/4" PVC SHEET W/ M1 TRIM, TYP.

2" RIGID NSULATION

ALUMINUM DRIP EDGESINGLE PLY MEMBRANE

ROOFING, WRAP OVER

PARAPET

1/2" ZIP SHEATHING

3-5/8" METAL STUD FRAMING

@ 16" O.C.

PVC SHEET W/ M1 TRIM, TYP.

2" RIGID NSULATION

ALUMINUM STOREFRONT

WINDOW FRAME

ALUMINUM DRIP EDGE

SINGLE PLY MEMBRANE ROOFING,

WRAP OVER PARAPET

OVERHEAD DOOR WITH

LIFT CLEARANCE TRACK

NEW 1 1/2" 20 GAUGE DECK

WITH 2" LIGHT WEIGHT

CONCRETE TOPPING

T / PARAPET

BASEMENT

1st FLOOR

'-6

'-4

TRUSS BRG.

'-0

BASEMENT

1st FLOOR

'-6

TRUSS BRG.

'-0

'-4

T / PARAPET

3 1/2" TRIM BOARD

W/ 1/2" PAD OUT, TYP.

NEW METAL ROOF DECK NEW METAL ROOF DECK NEW METAL ROOF DECK

1/2" COVERBOARD

1/2" COVERBOARD 1/2" COVERBOARD

4' -0

8"4"

CAULK AROUND PERIMETER

T / PARAPET

BASEMENT

1st FLOOR

'-6

'-4

TRUSS BRG.

'-0

2x BLOCKING 2x6 FRAMING

NEW CONCRETE SLAB-ON-GRADE

NEW 1 1/2" 20 GAUGE DECK

WITH 2" LIGHT WEIGHT

CONCRETE TOPPING

NEW 1 1/2" 20 GAUGE DECK

WITH 2" LIGHT WEIGHT

CONCRETE TOPPING

NEW CONCRETE

SLAB-ON-GRADE

A030

NEW ROOF TRUSS,

SEE STRUCTURAL

NEW ROOF TRUSS,

SEE STRUCTURAL

NEW ROOF TRUSS,

SEE STRUCTURAL

KICKER FRAMING,

SEE STRUCTURAL

KICKER FRAMING,

SEE STRUCTURAL

KICKER FRAMING, SEE STRUCTURAL

1' -6

/4

1'

-8

/4

1' -8

/4

6'

-9

/4

8' -2

/2

1' -7

/4

1'

-8

/4

1' -8

/4

3'

-9

/4

8' -1

/2

GENERAL NOTES FOR THIS SHEET

1. CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD.

NEW TAPERED RIGID INSULATION,

SLOPE FROM MIN. R-20 AT ALLEY

TO WEST FRONT STREET PARAPET

SPRAY FOAM INSULATION

FOR CONTINUOUS THERMAL

ENVELOPE

ALUMINUM FRAME TRIM

PRESSURE TREATED BLOCKING

1/2" SHEATHING

PRESSURE TREATED BLOCKING

3-1/2" TRIM ON UNDERSID

OF OVERHANG. BUTT

DENTIL TRIM M5 TO TRIM.

6" OUTRIGGER PROJECTION

4" OUTRIGGER PROJECTION

2 1/2" PAD OUT FRAMING

1" PAD OUT FRAMING

PRESSURE TREATED WOOD

FURRING, TYP.

M4 CORBEL TRIM, TYP.

3 1/2" TRIM BOARD

W/ 1/2" PAD OUT, TYP.

3/4" PVC SHEET W/ M1 TRIM, TYP.

PVC SHEET SOFFIT W/

BATTEN STRIPS AT JOINTS

PVC TRIM ON UNDERSIDE

3 1/2" TRIM BOARD

W/ 1/2" PAD OUT, TYP.

EXTEND PVC TO GRADE

WINDOW STEEL MOLDING M3

3-1/2" TRIM ON UNDERSID

OF OVERHANG. BUTT

DENTIL TRIM M5 TO TRIM.

5/8" OSB SHEATHING

W/ VAPOR BARRIER

5/8" OSB SHEATHING

W/ VAPOR BARRIER

5/8" OSB SHEATHING

W/ VAPOR BARRIER

2x10 BLOCKING FOR

FUTURE ALUMINUM/

FABRIC CANOPY

2x10 BLOCKING FOR

FUTURE ALUMINUM/

FABRIC CANOPY

1/2" OSB SHEATHING

D at e / T im e

Fi le

N am e

541 PHILADELPHIA ST.

INDIANA, PA 15701

PHONE (724)349-3601

911 MENOHER BLVD.

JOHNSTOWN, PA 15905

PHONE (814)539-0224

05/05/26

© 2025 UpStreet Architects, Inc.

245014

PH

A

SE

W

ES

T

FR

O N

T

ST

R

EE

T, BE

RW

IC

K, P

A

C O

B

LE

N

TZ

C O

R N

ER

/2 1/

/2

8/

/0

4/

WALL SECTIONS

A321

R

EV

IS

IO

N S

R

EV

D

AT

E D

ES

C

R

IP

TI

O

N O

F R

EV

IS

IO

N

BY sh N o C ha ng e sh N o C ha ng e rc p

Ad de nd um

R ev is io ns

3 3 3

3 3 3

3 3

1' -6

/4

1'

-8

/4

1' -8

/4

3'

-9

/4

8' -2

/2

1' -6

/4

1'

-8

/4

1' -8

/4

8'

-2

/2

6' -9

/4

SPRAY FOAM INSULATION

FOR CONTINUOUS THERMAL

ENVELOPE

SPRAY FOAM INSULATION

FOR CONTINUOUS THERMAL

ENVELOPE

A322

S. MARKET STREET WALL SECTION @ LOWER PARAPET

SCALE: 1/2" = 1'-0" 0 1 2 FT

A322

S. MARKET STREET WALL SECTION @ NEW CMU

SCALE: 1/2" = 1'-0" 0 1 2 FT

1/2" ZIP-SHEATHING, TYP.

3 5/8" METAL HAT CHANNEL @ 16" O.C.

PVC SHEET, TYP.

A322

S. MARKET STREET WALL SECTION @ UPPER PARAPET

SCALE: 1/2" = 1'-0" 0 1 2 FT

1/2" ZIP-SHEATHING, TYP.

3 5/8" METAL STUD @ 16" O.C.

PVC PANEL, TYP.

T / PARAPET

BASEMENT

1st FLOOR

'-6

'-4

TRUSS BRG.

'-0

T / PARAPET

BASEMENT

1st FLOOR

'-6

'-4

TRUSS BRG.

'-0

'-4

T / PARAPET

T / PARAPET

BASEMENT

1st FLOOR

'-6

'-4

TRUSS BRG.

'-0

NEW 1 1/2" 20 GAUGE DECK

WITH 2" LIGHT WEIGHT

CONCRETE TOPPING

NEW 1 1/2" 20 GAUGE DECK

WITH 2" LIGHT WEIGHT

CONCRETE TOPPING

1" SHEATHING PAD OUT

NEW 8" CMU

2" RIGID INSULATION2" RIGID INSULATION

1" SHEATHING PAD OUT

NEW 1 1/2" 20 GAUGE DECK

WITH 2" LIGHT WEIGHT

CONCRETE TOPPING

1/2" ZIP-SHEATHING, TYP.

PVC SHEET, TYP.

2" RIGID INSULATION

3 1/2" TRIM BOARD W/ 1/2" PAD OUT, TYP.

NEW STEEL BEAM, SEE

STRUCTURAL DRAWINGS

EXISTING STEEL BEAM

NEW STEEL BEAM REINFORCEMENT,

SEE STRUCTURAL DRAWINGS

NEW STEEL BEAM, SEE

STRUCTURAL DRAWINGS

WATER RESISTIVE BARRIER

MEMBRANE TO OVERLAP

FLASHINGS AND SCREEDS

DRAINAGE MAT (3/16" min.)

LATH, MORTAR SCRATCH COAT,

& MORTAR SETTING BED

ADHERED CONCRETE

MASONRY VENEER

WATER RESISTIVE BARRIER

MEMBRANE TO OVERLAP

FLASHINGS AND SCREEDS

DRAINAGE MAT (3/16" min.)

LATH, MORTAR SCRATCH COAT,

& MORTAR SETTING BED

ADHERED CONCRETE

MASONRY VENEER

WATER RESISTIVE BARRIER

MEMBRANE TO OVERLAP

FLASHINGS AND SCREEDS

DRAINAGE MAT (3/16" min.)

LATH, MORTAR SCRATCH COAT,

& MORTAR SETTING BED

ADHERED CONCRETE

MASONRY VENEER

WEEP SCREED w/ 3 1/2" min.

VERTICAL FLANGE

ZIP-SYSTEM LIQUID FLASH @

SHEATHING TO MASONRY TRANSITION

ZIP-SYSTEM LIQUID FLASH @

SHEATHING TO MASONRY TRANSITION

WEEP SCREED w/ 3 1/2" min.

VERTICAL FLANGE WEEP SCREED w/ 3 1/2" min.

VERTICAL FLANGE

EXISTING STEEL BEAM

NEW STEEL BEAM REINFORCEMENT,

SEE STRUCTURAL DRAWINGS

EXISTING STEEL BEAM

NEW STEEL BEAM REINFORCEMENT,

SEE STRUCTURAL DRAWINGS

KICKER FRAMING,

SEE STRUCTURAL

NEW MASONRY WALL. SEE STRUCTURAL

EXISTING MASONRY WALLEXISTING MASONRY WALLEXISTING MASONRY WALL

EXISTING STEEL BEAMS EXISTING STEEL BEAMS EXISTING STEEL BEAMS

NEW ROOF TRUSS,

SEE STRUCTURAL

NEW ROOF TRUSS,

SEE STRUCTURAL

NEW ROOF TRUSS,

SEE STRUCTURAL

NEW TAPERED

ROOF INSULATION

NEW ROOF DECK

KICKER FRAMING,

SEE STRUCTURAL

NEW TAPERED

ROOF INSULATION

NEW ROOF DECK

KICKER FRAMING,

SEE STRUCTURAL

NEW TAPERED

ROOF INSULATION

NEW ROOF DECK

GENERAL NOTES FOR THIS SHEET

1. CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD.

PARGE COATING BELOW VENEER PARGE COATING BELOW VENEER

PARGE COATING BELOW VENEER

PVC RETURN AT UNDERSIDE

3-1/2" TRIM ON UNDERSID

OF OVERHANG. BUTT

DENTIL TRIM M5 TO TRIM.

3-1/2" TRIM ON UNDERSID

OF OVERHANG. BUTT

DENTIL TRIM M5 TO TRIM.

3-1/2" TRIM ON UNDERSID

OF OVERHANG. BUTT

DENTIL TRIM M5 TO TRIM.

5/8" OSB SHEATHING

W/ VAPOR BARRIER

5/8" OSB SHEATHING

W/ VAPOR BARRIER

5/8" OSB SHEATHING

W/ VAPOR BARRIER

SPRAY FOAM INSULATION

FOR CONTINUOUS THERMAL

ENVELOPE

2x10 BLOCKING FOR FUTURE

ALUMINUM/FABRIC CANOPY

D at e / T im e

Fi le

N am e

541 PHILADELPHIA ST.

INDIANA, PA 15701

PHONE (724)349-3601

911 MENOHER BLVD.

JOHNSTOWN, PA 15905

PHONE (814)539-0224

05/05/26

© 2025 UpStreet Architects, Inc.

245014

PH

A

SE

W

ES

T

FR

O N

T

ST

R

EE

T, BE

RW

IC

K, P

A

C O

B

LE

N

TZ

C O

R N

ER

/2 1/

/2

8/

/0

4/

WALL SECTIONS

A322

R

EV

IS

IO

N S

R

EV

D

AT

E D

ES

C

R

IP

TI

O

N O

F R

EV

IS

IO

N

BY sh N o C ha ng e sh N o C ha ng e rc p

Ad de nd um

R ev is io ns

T / PARAPET

BASEMENT

1st FLOOR

'-6

'-4

TRUSS BRG.

'-0

T / PARAPET

BASEMENT

1st FLOOR

'-6

'-4

TRUSS BRG.

'-0

A323

WALL SECTION @ADJACENT BUILDING

SCALE: 1/2" = 1'-0" 0 1 2 FT

T / PARAPET

BASEMENT

1st FLOOR

'-6

'-4

TRUSS BRG.

'-0

A323

ALLEY WALL SECTION

SCALE: 1/2" = 1'-0" 0 1 2 FT

NEW ROOF TRUSS,

SEE STRUCTURAL

EXISTING MASONRY

WALL TO REMAIN

NEW METAL

ROOF DECK

TAPERED ROOF

INSULATION

NEW CONCRETE SLAB

ON COMPOSITE METAL

DECK, SEE STRUCTURAL

EXISTING BEAM TO REMAIN

NEW ROOF TRUSS,

SEE STRUCTURAL

EXISTING MASONRY

WALL TO REMAIN

NEW 8" ALUMINUM

BOX GUTTER

NEW CONCRETE SLAB

ON COMPOSITE METAL

DECK, SEE STRUCTURAL

EXISTING BEAM TO REMAIN

GENERAL NOTES FOR THIS SHEET

1. CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD.

ROOF MANUFACTURERS

ALUMINUM DRIP EDGE

TERMINATION DETAIL

MEMBRANE

ROOF

TAPERED RIGID

ROOF INSULATION

FLASH NEW ROOFING

TO ADJACENT BUILDING

W/ TERMINATION BAR

1/2" COVERBOARD

PATCH AND PAINT

NEW 2x8 PRESSURE

TREATED BLOCKING

NEW 2x PRESSURE

TREATED BLOCKING

MEMBRANE ROOF

RIGID INSULATION

MIN. R-20 AT LOWEST

EDGE

5/8" OSB SHEATHING

W/ VAPOR BARRIER

5/8" OSB SHEATHING

W/ VAPOR BARRIER

D at e / T im e

Fi le

N am e

541 PHILADELPHIA ST.

INDIANA, PA 15701

PHONE (724)349-3601

911 MENOHER BLVD.

JOHNSTOWN, PA 15905

PHONE (814)539-0224

05/05/26

© 2025 UpStreet Architects, Inc.

245014

PH

A

SE

W

ES

T

FR

O N

T

ST

R

EE

T, BE

RW

IC

K, P

A

C O

B

LE

N

TZ

C O

R N

ER

/2 1/

/2

8/

/0

4/

WALL SECTIONS

A323

R

EV

IS

IO

N S

R

EV

D

AT

E D

ES

C

R

IP

TI

O

N O

F R

EV

IS

IO

N

BY sh N o C ha ng e sh N o C ha ng e rc p

Ad de nd um

R ev is io ns

ADJACENT BUILDING

DS

KO

KO

N O

RT

H 1

A401

ROOF PLAN

SCALE: 1/4" = 1'-0" 0 4 8 FT

SLOPE

SLOPE

1. SEE GENERAL ROOF PLAN NOTES ON A001.

2. (DS) INDICATES DOWNSPOUT LOCATIONS.

3. (KO) INDICATES KICK-OUT FLASHING LOCATIONS.

4. MEMBRANE ROOF DESIGN & SLOPES TO BE

VERIFIED BY ROOFING MANUFACTURER. SLOPE

TO BE 1/4":12 min. ROOFER MUST BE CERTIFIED BY

THE ROOFING MANUFACTURER. MANUFACTURER

MUST PROVIDE INSPECTION REPORT FOR

WARRANTY VERIFICATION.

5. INSTALL 36" WIDE REINFORCED PVC WALKING

PADS FOR A 100' WALKING PATH TO BE

DETERMINED IN THE FIELD.

6. CRICKETS ARE CREATED WITH TAPERED

INSULATION TO SLOPE TO DRAIN. ALL ROOF

SURFACES TO SLOPE 1/4" PER FOOT MIN.

7. FLASH PLUMBING VENTS. SEE PLUMBING

DRAWINGS & DETAIL 3/A601.

8. ROOFER IS RESPONSIBLE TO COORDINATE WITH

G.C. AND MECHANICAL SUBCONTRACTOR TO

DETERMINE ALL FIELD PENETRATIONS AND

CURBS REQUIRED.

9. INSTALL NEW METAL ROOF JOISTS. SEE

STRUCTURAL DRAWINGS.

10. WRAP ROOFING OVER PARAPET WALL AND UNDER

COPING OR DRIP EDGE.

GENERAL NOTES FOR THIS SHEET

SLOPE

SLOPE

P2

SLOPE

WALLS BELOW

WALLS BELOW

A321

A321

A321

A322

A323

A322

A322

P1

P1P2

NEW INSULATION AND MEMBRANE ROOFING SYSTEM

ON NEW METAL ROOF DECK .

WRAP ROOFING MEMBRANE OVER PARPAPET.2

NOT USED.3

WRAP NEW MEMBRANE ROOF TO TOP OF PARAPET AND

FLASH TO ADJACENT BUILDING. SEE DETAIL 1/A602.

NOT USED.6

PROVIDE CRICKET AROUND ROOF HATCH AND

CHIMNEY.

ROOF HATCH. SEE DETAIL 7/A601. INSTALL PER

MANUFACTURER'S DETAILS.

NEW ALUMINUM CHIMNEY CAP. SEE DETAIL 2/A601.

NUMBERED NOTES FOR THIS SHEET

EXISTING CHIMNEY TO BE REPAIRED/REPOINTED.

NEW ALUMINUM GUTTER AND DOWNSPOUTS. SEE

DETAIL 3/A601.

CORNICE TYPES:

HIGH PARAPET, SEE WALL SECTION.P1

LOW PARAPET, SEE WALL SECTION.P2

A323

A301

A301

D at e / T im e

Fi le

N am e

541 PHILADELPHIA ST.

INDIANA, PA 15701

PHONE (724)349-3601

911 MENOHER BLVD.

JOHNSTOWN, PA 15905

PHONE (814)539-0224

05/05/26

© 2025 UpStreet Architects, Inc.

245014

PH

A

SE

W

ES

T

FR

O N

T

ST

R

EE

T, BE

RW

IC

K, P

A

C O

B

LE

N

TZ

C O

R N

ER

/2 1/

/2

8/

/0

4/

ROOF PLAN

A401

R

EV

IS

IO

N S

R

EV

D

AT

E D

ES

C

R

IP

TI

O

N O

F R

EV

IS

IO

N

BY sh N o C ha ng e sh N o C ha ng e sh Ad de nd um

R ev is io

03 D401 Demo Roof Plan
05 A001 General Notes
05 A002 Site Plan
05 A010 Door Schedule
05 A030 Window Schedule-Detls
05 A201 Elevations
05 A202 Elevations
05 A321 Wall Sections
05 A322 Wall Sections
05 A323 Wall Sections
05 A401 Roof Plan

File details come from the government source that posted it. Updated .