118-GUIDE_SHEET_-_Parallel_&_Perpendicular_Ramp(s).pdf

PDF 314 KB Posted

Attached to
Citywide Sidewalk, Curb, Apron & ADA Ramp Repair and Replacement
Solicitation number
CWB014279
Issued by
Fairfield County, Bridgeport City, Connecticut

About this file

This is a Connecticut Department of Transportation (CTDOT) design standard guide sheet for concrete sidewalk ramps, specifically addressing parallel and perpendicular ADA-compliant ramp configurations. The document establishes technical specifications for curb ramp construction across Connecticut municipalities, including the City of Bridgeport. Key specifications include maximum ramp slopes of 8.33 percent with a typical slope of 7.1 percent, minimum turning spaces of 48 to 60 inches depending on ramp type, detectable warning surfaces extending a minimum of 2 feet in the direction of pedestrian travel, and vertical surface discontinuities at joints not exceeding 1/4 inch. The guide sheet presents ten distinct ramp types (Types 8, 9, 10a, and 10b detailed) for various constrained and unconstrained site conditions. All specifications comply with the 2013 Public Right-of-Way Accessibility Guidelines (PROWAG) draft standards and are designed to ensure water drainage and pedestrian safety.

The document references CTDOT Engineering Directive ED-2019-7 and establishes that sidewalk ramps must have a coarse broom finish transverse to the slope, with removal of existing sidewalk for new installations required to the nearest inch. The guide sheet was last updated on October 30, 2024, and was prepared for implementation across Connecticut towns. While this design standard document itself does not contain pricing, set-asides, or funding information, it serves as the technical specification baseline for the related City of Bridgeport Citywide Sidewalk, Curb, Apron & ADA Ramp Repair and Replacement project, with bids due by September 22, 2026, through the City's OpenGov e-Procurement portal.

View the file

Other files

File Type Posted
HW-0813_02_-_Stone_Curbing.pdf PDF
133-GUIDE_SHEET_-_Pedestrian_Refuse_Island(s).pdf PDF
Sidewalk_Specifications_&_Standard_Details.pdf PDF
121-GUIDE_SHEET_-_Perpendicular_Ramp(s).pdf PDF
HW-0922_01_-_Bituminous_Concrete_Sidewalk_&_Driveway.pdf PDF
HW-0815_01_-_Bituminous_Curbing.pdf PDF
124-GUIDE_SHEET_-_Single_Direction_Perpendicular_Ramp(s).pdf PDF
136-GUIDE_SHEET_-_Railroad_Crossing_Ramp(s).pdf PDF
130-GUIDE_SHEET_-_Restricted_Pedestrian_Crossing_Ramp(s).pdf PDF
139-GUIDE_SHEET_-_Driveway(s).pdf PDF
HW-0813_01_-_Granite_Transistion_Curbing.pdf PDF
Construction_Contract.pdf PDF
127-GUIDE_SHEET_-_Penpendicular_Ramp(s).pdf PDF
Sidewalk_Repair_Work_Order_-_Draft_-_v4.2.5.pdf PDF
115-GUIDE_SHEET_-_Perpendicular_Ramp(s)_with_Street.pdf PDF
112-GUIDE_SHEET_-_Two_Directional_Perpendicular_&_Blended_Ramp(s).pdf PDF
HW-0803_01_-_Paved_Aprons.pdf PDF
HW-0921_01_-_Concrete_Sidewalks.pdf PDF
109-GUIDE_SHEET_-_Basic_Ramp.pdf PDF
HW-0811_01_-_Concrete_Curb.pdf PDF
Construction_Services_Insurance_Rider_-_2026_08_28.pdf PDF
HW-0924_01_-_Concrete_Driveway_Ramps.pdf PDF
106-GUIDE_SHEET_-_General_Sidewalk_Ramp(s).pdf PDF
General_Conditions_-_Final_Rev._Feb_2026_-_Higher_Limits.pdf PDF
Instruction_to_Sidewalk_Bidders_-_2026_08_28.pdf PDF
Invitation_To_Sidewalk_Bid_-_2026_08_28.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

8.33% MAX.

7.1% TYP.

RAMP SLOPE

2.0% MAX.

1.5% TYP.

SPACE

TURNING

60" MIN.

8.33% MAX.

7.1% TYP.

RAMP SLOPE

48" MIN.

CURBING

WITH RAMP (TYP.)

SLOPED CURBING INCLUDED

RAMP (TYP.)

INCLUDED WITH

SLOPED CURBING

NON-WALKING SURFACE

48" MIN.

(TYPE 9)

ON TWO (2) OR MORE SIDES

TURNING SPACE CONSTRAINED

PARALLEL RAMP WITH

48" MIN. (REVEAL SHALL NOT EXCEED 12")

SIDEWALK CURBING (OPTIONAL)

8.33% MAX.

7.1% TYP.

RAMP SLOPE

2.0% MAX.

1.5% TYP.

SPACE

TURNING

48" MIN.

48" MIN.

WITH RAMP (TYP.)

SLOPED CURBING INCLUDED

CURBING

NON-WALKING SURFACE

MIN.

48"

(TYPE 10a)

CONSTRAINED ON ONE SIDE

WITH TURNING SPACE

PARALLEL RAMP

R=2' MIN.

GENERAL NOTES:

PEDESTRIAN ACCESS ROUTE.

9. CURB RAMPS SHALL BE CONSTRUCTED SO THAT WATER WILL NOT ACCUMLATE WITHIN THE

SEE ENGINEERING DIRECTIVE ED-2019-7.

8. CTDOT DESIGN STANDARD USE THE PUBLIC RIGHT-OF-WAY ACCESSIBILITY GUIDELINES (PROWAG)

WILL BE MADE TO COMPLY WITH PROWAG FINAL RULE ONCE OFFICIALLY THE LAW.

7. ALL GUIDESHEET VALUES COMPLY WITH PROWAG DRAFT 2013 GUIDELINES. UPDATED VALUES

TRAVEL AND SPAN THE ENTIRE RAMP OPENING.

6. DETECTABLE WARNING SURFACES SHALL EXTEND 2 FEET MIN. IN THE DIRECTION OF PEDESTRIAN

OR HIGHWAYS.

STREET CROSSINGS, PEDESTRIAN REFUGE ISLANDS AND RAILROAD CROSSINGS ALONG STREETS

5. DETECTABLE WARNING SURFACES SHALL BE INSTALLED ON SIDEWALK RAMPS AT PEDESTRIAN

REQUIRE THE RAMP LENGTH TO EXCEED 15 FEET.

4. THE RUNNING SLOPE OF THE CURB RAMP SHALL BE 8.33 PERCENT MAXIMUM BUT SHALL NOT

EXPANSION OR CONTRACTION JOINT.

3. REMOVAL OF EXISTING SIDEWALK FOR NEW RAMP INSTALLATIONS SHALL BE TO THE NEAREST

INCH.4

2. VERTICAL SURFACE DISCONTINUITIES AT JOINTS SHALL NOT EXCEED

1. SIDEWALK RAMPS SHALL HAVE A COARSE BROOM FINISH TRANSVERSE TO THE SLOPE OF THE RAMP.

SURFACE (SEE NOTE 6)

WARNING DETECTABLE

0" - 1/4" MAX.

LIP HEIGHT

SURFACE (SEE NOTE 6)

WARNING DETECTABLE

0" - 1/4" MAX.

LIP HEIGHT

8.33% MAX.

7.1% TYP.

RAMP SLOPE

WITH RAMP (TYP.)

SLOPED CURBING INCLUDED

(TYPE 8)

WITH 48" BY-PASS

PERPENDICULAR RAMP

MAX.

10%

2.0% MAX.

1.5% TYP.

TURNING SPACE

48" MIN.

MAX.

10%

SURFACE (SEE NOTE 6)

DETECTABLE WARNING

0" - 1/4" MAX.

LIP HEIGHT

NON-WALKING SURFACE

8.33% MAX.

7.1% TYP.

RAMP SLOPE

2.0% MAX.

1.5% TYP.

SPACE

TURNING

48" MIN.

48" MIN.

WITH RAMP (TYP.)

SLOPED CURBING INCLUDED

CURBING

CURBING

NON-WALKING SURFACE

MIN.

60"

SLOPED CURBING INCLUDED WITH RAMP

R=2' MIN.

(REVEAL SHALL NOT EXCEED 12")

SIDEWALK CURBING

(TYPE 10b)

CONSTRAINED ON TWO (2) OR MORE SIDES

WITH TURNING SPACE

PARALLEL RAMP

SURFACE (SEE NOTE 6)

WARNING DETECTABLE

0" - 1/4" MAX.

LIP HEIGHT

PROJECT TITLE: PROJECT NO.: DRAWING NO.:

SHEET NO.:

10/30/2024

SIGNATURE BLOCK: DRAWING TITLE:

TOWN(S):

VARIOUSTEST PROJECT

PLOTTED DATE:

C:\Users\KIlpatrickdj\State of Connecticut\DOT Engineering Services - Documents\HWY_STD_GUIDE_DWG\B - Going for signatures\Jan 2025 Stnd & Guide Shts\CTDOT_HIGHWAY_GD Jan 2025 [10-30-24].dgn FILE NAME: kilpatrickdj LASTED SAVED BY:

R E

V

D A

T E

R E

V

IS

IO

N

D E

S C

R

IP

T

IO

N

DESIGNER/DRAFTER: CHECKED BY:

SHEET 4 OF 11

CONCRETE SIDEWALK RAMPS

TRANSPORTATION

DEPARTMENT OF

CONNECTICUT