This solicitation is for a total small business set-aside contract to replace three trail bridges in the Superior National Forest. The work includes traffic control, demolition of existing bridges, installation of new timber abutments and wing walls with associated hardware, furnishing and placing aggregate, installing permanent bridge signs and object markers, furnishing and installing dowel-laminated timber deck systems with curb and railing systems, seeding and mulching disturbed areas, and protecting waterways. Bids will be accepted at the Superior National Forest Supervisors Office by the date specified in the Invitation for Bids. The three bridges included in the project are the Pincushion Mountain Loop Bridge #2, Pincushion Mountain Loop Bridge #6, and the Caribou Snowmobile Trail No. 91044 bridge over Noname Creek.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
United States Department of Agriculture Forest Service
EASTERN REGION
SUPERIOR NATIONAL FOREST - GUNFLINT RANGER DISTRICT
COOK COUNTY
MINNESOTA
PINCUSHION MOUNTAIN LOOP
TRAIL BRIDGE #6 REPLACEMENT @ MP 0.545
TO MAPLE HILL
BRIDGE #1
(17 TON CAPACITY)
JUNCTION B
PROJECT
LOCATION
JUNCTION E
JUNCTION D
NORTH COUNTRY
NATIONAL SCENIC TRAIL
BRIDGE #7
(15 TON CAPACITY)
JUNCTION F
RECOMMENDED BY:
STEPHEN
POPKOWSKI
Digitally signed by STEPHEN
POPKOWSKI
Date: 2023.06.05 10:32:27 -05'00'
SUPERIOR
HIKING TRAIL
FOREST ENGINEER DATE
Digitally signed by MYRA
TO GRAND
MARAIS
THEIMER
Date: 2023.06.06 11:24:34 -05'00'
DISTRICT RANGER DATE
PINCUSHION TRAIL HEAD
PROJECT SITE
FROM THE US HWY 61 / GUNFLINT TRAIL INTERSECTION NORTHEAST OF
GRAND MARAIS, MINNESOTA, HEAD NORTH ON GUNFLINT TRAIL FOR 2.5
MILES, THEN TURN RIGHT ONTO PINCUSHION DRIVE. CONTINUE ON
PINCUSHION DRIVE FOR 0.2 MILES TO THE TRAIL HEAD. CONTINUE ON
THE WEST OVERLOOK TRAIL FOR 0.5 MILES, THEN TURN RIGHT AT
JUNCTION B. CONTINUE ON PINCUSHION MOUNTAIN LOOP FOR 0.83
MILES TO JUNCTION E. CONTINUE ON PINCUSHION MOUNTAIN LOOP FOR
0.1 MILES TO BRIDGE LOCATION.
FOREST SUPERVISOR DATE
R9 BRIDGE PROGRAM MANAGER DATE
APPROVED:
PROJECT LOCATION R9 DIRECTOR OF ENGINEERING DATE
SHEET 1 OF 10
STRUCTURE NUMBER: 090902-21025E SNOW-0.545 (LAT 47.7759, LONG -90.3037)
PROPOSED STRUCTURE DESCRIPTION:
27.5 FOOT (OVERALL LENGTH) SINGLE SPAN, DOWEL-LAM SLAB BRIDGE
WITH TIMBER CRIB FOUNDATIONS.
5/1 0/2
:5
JA
LL
EN
Z
:\U
-0
U
SD
A
FS
R
TS
T-
US
FS
B
RI
DG
E
ID
IQ
BR
ID
GE
S\
DW
GS
\T
AS
K
- S
UP
ER
IO
RN
F
- P
IN
CU
SH
IO
N
LO
OP
6\M P
0.5
PI
NC
US
HI
ON
L
OO
P# 6.D
W G;
MYRA THEIMER
PROJECT LOCATION:
INDEX OF SHEETS
SHEET SHEET TITLE DATE
G-01 TITLE SHEET 5/12/2023
C-02 GENERAL NOTES 5/12/2023
C-03 TEMPORARY TRAIL CLOSURE 5/12/2023
C-04 TYPICAL SECTIONS 5/12/2023
C-05 PLAN OF SITE 5/12/2023
C-06 PROFILE OF SITE 5/12/2023
C-07 PLAN OF STRUCTURE 5/12/2023
C-08 ABUTMENT PLAN AND ELEVATION 5/12/2023
C-09 STRUCTURE DETAILS 5/12/2023
C-10 QUANTITIES & MISCELLANEOUS DETAILS 5/12/2023
DESIGN DATA:
LIVE LOAD DEFLECTION DOES NOT EXCEED 1/360 OF THE SPAN LENGTH.
PEDESTRIAN LIVE LOAD = 90 PSF
LOAD RATING (RATING FACTORS):
H-10 (CONCURRENT WITH SNOW LOAD)
INVENTORY RATING (STRENGTH 1, DECK, MOMENT). ....................................................................................................... 1.55
OPERATING RATING (STRENGTH 1, DECK, MOMENT). ....................................................................................................... 2.01
H-15 (WITHOUT SNOW LOAD)
INVENTORY RATING (STRENGTH 1, DECK, MOMENT). ....................................................................................................... 1.23
OPERATING RATING (STRENGTH 1, DECK, MOMENT). ....................................................................................................... 1.60
DEAD LOAD:
THE DESIGN UNIT WEIGHT FOR ALL TIMBERS. ............................................................................................................. 50 PCF
THE BRIDGE CURB LOAD. .............................................................................................................................. 28 PLF (PER SIDE)
SNOW LOAD. ............................................................................................................................................................................. 70 PSF
HYDRAULIC DATA:
100 YEAR FREQUENCY
DRAINAGE AREA. .................................................................................................................................................................. SQ MI
Q100. ................................................................................................................................................................................... 73.2 CFS
VELOCITY THRU STRUCTURE.................................................................................................................................... 5.87 FPS
BRIDGE OPEN AREA THRU STRUCTURE. ........................................................................................................ 70.75 SQ FT
FLOW AREA THRU STRUCTURE. ......................................................................................................................... 14.91 SQ FT
HIGH WATER ELEVATION. ........................................................................................................................................ 1143.58 FT
SCOUR CRITICAL CODE
GENERAL NOTES:
EXCEPT WHERE OTHERWISE INDICATED ON THESE PLANS OR IN THE SUPPLEMENTAL SPECIFICATIONS, ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE FHWA STANDARD SPECIFICATIONS FOR CONSTRUCTION OF ROADS AND BRIDGES ON FEDERAL HIGHWAY PROJECTS, FP-14.
THE PROPOSED IMPROVEMENTS COVERED BY THESE PLANS ARE IN ACCORDANCE WITH:
LRFD GUIDE SPECIFICATIONS FOR THE DESIGN OF PEDESTRIAN BRIDGES, DECEMBER 2009. WITH 2015 INTERIM REVISIONS.
AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, 9TH EDITION, 2020
AASHTO GUIDELINES FOR GEOMETRIC DESIGN OF LOW-VOLUME ROADS, 2ND EDITION, 2019
FSH 7709.56b TRANSPORTATION STRUCTURES HANDBOOK (USDA FOREST SERVICE) TIMBER BRIDGES: DESIGN, CONSTRUCTION, INSPECTION, AND MAINTENANCE (USDA FOREST SERVICE)
NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION 2018
THE EXISTING STRUCTURE SHALL BE CHECKED AT THE TIME OF STARTING CONSTRUCTION TO SEE THAT ITS RELATIONSHIP TO THE PROPOSED WORK IS AS SHOWN ON THESE PLANS AND ANY DIFFERENCES REQUIRING CHANGES IN THE NEW WORK SHALL BE REPORTED TO THE PROJECT ENGINEER.
THE WORK COVERED BY THESE PLANS INCLUDES REMOVAL OF THE ENTIRE EXISTING BRIDGE, INSTALLATION OF THE NEW BRIDGE AS SHOWN HEREIN AND PER THE MANUFACTURER'S DRAWINGS AND SPECIFICATIONS, CONSTRUCTION OF THE APPROACHES TO THE LIMITS SHOWN, AND SLOPE
RESTORATION.
THE STATIONING AS SHOWN ON THESE PLANS FOR REFERENCE POINTS "A" AND "B" ARE BELIEVED TO BE CORRECT. IT SHALL, HOWEVER, BE CHECKED AT THE TIME OF STARTING CONSTRUCTION, AND IF THE STATIONING SHOWN ON THE PLANS IS INCORRECT, IT SHALL BE REPORTED TO THE ENGINEER.
THE CONTRACTOR SHALL COORDINATE ALL OF THEIR WORK AND ANY UTILITY COMPANIES RELOCATION WORK AT NO ADDITIONAL COST TO THE
PROJECT.
FOR PROTECTION OF UNDERGROUND UTILITIES AND IN CONFORMANCE WITH PUBLIC ACT 174, THE CONTRACTOR SHALL DIAL "811" A MINIMUM OF THREE FULL WORKING DAYS, EXCLUDING SATURDAYS, SUNDAYS AND HOLIDAYS PRIOR TO BEGINNING EACH EXCAVATION IN AREAS WHERE PUBLIC
GENERAL NOTES:
NO WORK SHALL BE PERFORMED ON FEDERAL HOLIDAYS OR WEEKENDS WITHOUT PRIOR APPROVAL FROM THE FOREST SERVICE CONTRACTING
OFFICER REPRESENTATIVE.
THE CONTRACTOR SHALL NOT PERFORM IN-STREAM WORK BETWEEN APRIL 1ST THROUGH JUNE 30TH. NO IN-STREAM WORK SHALL BE PERFORMED
AFTER SEPTEMBER 15TH.
THE CONTRACTOR SHALL VERIFY WITH THE FOREST SERVICE CONTRACTING OFFICER REPRESENTATIVE THAT THE BAT SURVEY HAS BEEN
COMPLETED PRIOR TO BEGINNING CONSTRUCTION.
SPECIFICATIONS:
ALL GRADING COMBINATIONS, AND SIZE REFER TO DOUGLAS FIR UNLESS SHOWN OTHERWISE ON THE PLANS. THE DESIGN VALUES FOLLOW LRFD BRIDGE DESIGN SPECIFICATIONS. THESE ARE THE MINIMUM REQUIREMENTS. OTHER SPECIES MAY BE USED WITH APPROVAL FROM THE FOREST
SERVICE CONTRACTING OFFICER REPRESENTATIVE
GRADING:
ALL DOUGLAS FIR-LARCH TO BE GRADED PER WCLIB STANDARD GRADING RULES. SOUTHERN PINE TO BE GRADED PER SPIB.
MATERIAL & TREATMENT:
TIMBER PRESERVATION TREATMENT SHALL BE IN ACCORDANCE WITH CURRENT STATE AND/ OR AASHTO SPECIFICATIONS. ALL TIMBER SHALL BE TREATED WITH COPPER NAPHTHENATE IN HYDROCARBON SOLVENT A, PER AWPA, UC4C (MINIMUM).
REFERENCE DESIGN VALUES SHOWN ARE PER AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, 9TH EDITION, 2020 (U.N.O.)
DECK TO BE 12" DOUGLAS FIR-LARCH, NO.1 & BETTER (> 2 INCH WIDE) S1S. REFERENCE DESIGN VALUES (KSI): Fbo = 1.20, Fvo = 0.18, Eo = 1,800
SPREADER BEAMS TO BE DOUGLAS FIR-LARCH, NO.1 (BEAMS AND STRINGERS). REFERENCE DESIGN VALUES (KSI): Fbo = 1.35, Fvo = 0.17, Eo = 1,600
CURBS & SCUPPERS TO BE DOUGLAS FIR-LARCH NO.1 (POSTS AND TIMBERS) S1S1E. REFERENCE DESIGN VALUES (KSI): Fbo = 1.20, Fvo = 0.17, Eo = 1,600
TIMBER CRIBBING SHALL BE SOUTHERN PINE NO. 1 OR BETTER (5" x 5" AND LARGER), Fb = 1,350 PSI
ALL TIMBER IS ROUGH UNLESS OTHERWISE NOTED.
MISCELLANEOUS:
ALL TIMBER TO BE CUT EXACT LENGTH, DRESSED TO SIZE REQUIRED AND ALL PRACTICAL FRAMING TO BE DONE PRIOR TO TREATMENT.
ALL DECK PLANKS SHALL BE PREDRILLED PRIOR TO TREATMENT.
ALL PLANK FOR DECK PANELS SHALL BE PRECISION END TRIMMED TO LENGTH WITH 1/4" UNDERLENGTH & NO OVERLENGTH TOLERANCE PERMITTED.
DECK PANELS SHALL BE ASSEMBLED WITH 3/8" DIAMETER RING SHANK DOWELS. ALL DOWELS ARE TO BE SIMULTANEOUSLY DRIVEN WITH EQUAL FORCE USING A MECHANICAL PRESS THE FULL LENGTH OF THE DECK. ENSURING ALL HEADS ARE FLUSH WITH THE SURFACE OF THE TIMBER PLANK.
MULTIPLE IMPACT TOOLS ARE NOT TO BE USED TO SET DOWELS BECAUSE OF POTENTIAL FOR WOOD FIBER RUPTURE.
SUBMIT SHOP DRAWINGS FOR BRIDGE DECK AND RAILINGS.
DECK PANELS WILL BE DELIVERED TO JOBSITE AFTER BEING FULLY ASSEMBLED AT FABRICATION PLANT.
ALL HARDWARE FOR TIMBER CONNECTIONS TO MEET ASTM A307-97 GALVANIZED TO F2329 (A153). ALL HIGH STRENGTH HARDWARE FOR CURB AND SPREADER BEAM CONNECTIONS TO MEET ASTM F3125 GRADE A325 OR GRADE A449 GALVANIZED TO A153.
OBJECT MARKERS SHALL BE 72 INCH, YELLOW FLEXIBLE CARSONITE MARKERS WITH BLACK AND YELLOW REFLECTIVE STRIPING.
CONSTRUCTION NOTES:
THE CONTRACTOR SHALL SUBMIT A RIPRAP GRADATION TEST RESULT ACCORDING TO ASTM D5519 PRIOR TO PLACING ROCK.
DOWEL LAMINATED DECK:
TIMBER DECK PANELS ARE MARKED IN THE SHOP FOR USE IN FIELD PLACEMENT OF THE PANELS ON THE CAPS, e.g. A1, B1, C1.
PANEL "A" IS PLACED FIRST IN ITS FINAL POSITION ON THE CAPS. NEXT DRILL THE 11/16" DIA. HOLES THRU PANEL INTO CAP IN EACH END OF PANEL AT THE LOCATION SHOWN AND FASTEN THE 3/4" DIA. DM. HD. DR. SPKS. NEXT PLACE PANEL "C" SO THAT ITS UPPER SPLICE BLOCK IS DIRECTLY OVER THE LOWER SPLICE BLOCK ON PANEL "A" AND DRAW TIGHT TOGETHER. THEN DRILL THE 9/16" DIA. HOLES THRU LOWER SPLICE BLOCK AND DRIVE THE 5/8" DM. HD. DR. SPIKES IN LOCATION SHOWN. THEN DRILL HOLES THRU PANEL INTO CAP AND FASTEN THE 3/4" DM. HD. DR. SPKS. THEREAFTER, SUCCESSIVELY PLACE PANEL "B" IN THE SAME MANNER, ENSURING ALL PANELS ARE DRAWN TIGHT TOGETHER BEFORE ANY FASTENING OCCURS.
STEEL BANDING ON PANELS IS TO BE REMOVED AFTER PANELS HAVE BEEN PLACED IN THEIR FINAL POSITION ON THE CAPS.
ALL HOLES DRILLED IN THE FIELD WHERE SPIKES ARE USED ARE TO BE 1/16" SMALLER THAN THE SPIKE SIZE.
ALL HOLES DRILLED FOR BOLTS ARE TO BE 1/16" LARGER THAN BOLT SIZE.
United States Department of Agriculture Forest Service
EASTERN REGION
PROJECT NAME
PINCUSHION MOUNTAIN
LOOP TRAIL BRIDGE #6
REPLACEMENT@ MP 0.545
SUPERIOR
NATIONAL FOREST
GUNFLINT
RANGER DISTRICT
DRAWING TITLE
GENERAL NOTES
DATE
ARCHIVE NO.
UTILITIES HAVE NOT BEEN PREVIOUSLY LOCATED. MEMBERS WILL THUS BE ROUTINELY NOTIFIED. THIS DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF NOTIFYING UTILITY OWNERS WHO MAY NOT BE A PART OF THE "GOPHER STATE ONE CALL" ALERT SYSTEM.
IN LIEU OF A GEOTECHNICAL INVESTIGATION, THE FOUNDATIONS WERE DESIGNED WITH A MAXIMUM BEARING PRESSURE OF 1,300 PSF FOR THE SERVICE LIMIT STATE AND 2,000 PSF FOR THE STRENGTH LIMIT STATE, BASED ON GROSS WIDTH OF THE FOOTING. THE CONTRACTOR SHALL VERIFY SOILS PRIOR TO CONSTRUCTION OF ABUTMENTS BY HAND PROBE, HAND DIGGING AND/OR BACKHOE TO A MINIMUM DEPTH OF 4 FEET BELOW THE BOTTOM OF FOOTING. IF ORGANIC, SOFT OR OTHERWISE UNSUITABLE SOILS ARE ENCOUNTERED, HE SHALL CONTACT THE FOREST SERVICE
CONTRACTING OFFICER REPRESENTATIVE FOR FURTHER INSTRUCTION.
WATER LEVEL IS SUBJECT TO CHANGE. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE EXPECTED WATER LEVELS DURING
CONSTRUCTION.
NO MATERIAL SHALL BE ALLOWED TO ERODE INTO THE WATER COURSE, NOR SHALL MATERIAL BE PLACED INTO THE WATER COURSE EXCEPT AS
SHOWN ON THESE PLANS.
ALL EQUIPMENT SHALL BE CLEANED ACCORDING TO THE SPECIFICATIONS PRIOR TO USE ON THIS PROJECT. CONTRACTOR SHALL MAKE EQUIPMENT
AVAILABLE FOR INSPECTION PRIOR TO MOBILIZATION ONTO FS LANDS.
THE CONTRACTOR SHALL STOP WORK IMMEDIATELY AND NOTIFY THE FOREST SERVICE CONTRACTING OFFICER REPRESENTATIVE IF HERITAGE
RESOURCES OR HUMAN REMAINS ARE ENCOUNTERED.
HOLES DRILLED FOR 3/4" LAG BOLTS ARE TO BE 9/16" IN DIAMETER FOR THE THREADED PORTION OF THE BOLT AND 13/16" FOR THE SHANK.
ANY NUT OR MACHINE BOLT HEAD IN DIRECT CONTACT WITH TIMBER TO HAVE ONE PLATE WASHER BETWEEN NUT & TIMBER, AND BOLT HEAD &
TIMBER.
ANY NUT OR MACHINE BOLT HEAD IN DIRECT CONTACT WITH STEEL TO HAVE ONE CUT WASHER BETWEEN NUT & STEEL, OR BOLT HEAD & STEEL.
SET THREADS ON ALL BOLTS AT NUT WITH A CENTER PUNCH AFTER TIGHTENING.
ABUTMENTS TO BE BACKFILLED WITH CLEAN GRANULAR FILL PER PLAN. TIMBER CRIBBING TO BE FILLED IN WITH RIPRAP, CLASS 0, MACHINE PLACED.
ALL TIMBER CUT OR DRILLED IN THE FIELD SHALL BE TREATED WITH COPPER NAPHTHENATE (MATCH PROVIDED TREATMENT TYPE).
ALTHOUGH ALL PRACTICAL PRE-FRAMING WILL BE DONE PRIOR TO TREATING, SOME CUTTING & DRILLING WILL BE REQUIRED IN THE FIELD.
IF GALVANIZED FASTENERS ARE CUT OR DAMAGED IN THE FIELD, THEY SHALL BE REPLACED OR TOUCHED UP WITH COLD GALVANIZING COMPOUND
AT THE DISCRETION OF THE FOREST SERVICE CONTRACTING OFFICER REPRESENTATIVE.
DESIGNER
C.SMITH
DRAWN
J.ALLEN
CHECKED
G.JUNTTILA
PROJECT NO.
U28-02592
DWG SHEET NO.
SHEET 2 OF
Forest Service
EASTERN REGION
W20-3
W20-3
MOUNTED
ON BARRICADE
R11-2 PROJECT NAME
PINCUSHION MOUNTAIN
LOOP TRAIL BRIDGE #6
REPLACEMENT@ MP 0.545
SUPERIOR
NATIONAL FOREST
GUNFLINT
RANGER DISTRICT
DRAWING TITLE
TEMPORARY
TRAIL CLOSURE
DATE
TRAFFIC CONTROL PLAN KEY
SIGN
TYPE III BARRICADE
ARCHIVE NO.
ALL SIGNS, EXCEPT THOSE MOUNTED ON TYPE III BARRICADES SHALL BE
MOUNTED ON DRIVEN POSTS AT A 7 FOOT BOTTOM HEIGHT.
DETOUR NOTES:
A DETOUR ROUTE IS NOT AVAILABLE FOR THE PROJECT LOCATION.
DESIGNER
C.SMITH
DRAWN
J.ALLEN
DWG SHEET NO.
CHECKED
G.JUNTTILA
PROJECT NO.
U28-02592
SHEET 3 OF
PINCUSHION TRAILS BED AND BREAKFEST
LYNN'S LOOP
TO MAPLE HILL JUNCTION O
NORTH ADVANCED
UPPER SNOWMAN
NORTH ADVANCED
HILFIKER HILL
DEVILS TRACK NORDIC SKI SHOP
OLE HYVAA
LOWER SNOWMAN PROJECT
LOCATION
JUNCTION E
21025E SNOW
NORTH ADVANCED
BRIDGE #1
(17 TON CAPACITY)
(2) TYPE III BARRICADES, LIGHTED
AT EACH END OF WORK ZONE
JUNCTION B 3K CUT OFF
JUNCTION A JUNCTION D
WEST OVERLOOK JUNCTION C
BRIDGE #7
(15 TON CAPACITY)
PINCUSHION
MOUNTAIN
LOOP
NORTH COUNTRY
NATIONAL SCENIC TRAIL
JUNCTION F
SUPERIOR
HIKING TRAIL
21025E SNOW
TO GRAND MARAIS
PINCUSHION TRAIL HEAD
7.0' LANE
VARIES
7.0' LANE
EX GRADE
VARIES
EX BASE - GRAVEL/ SILTY SAND
5.08'
EXISTING ℄
GRADE
10.16'
5.08' NOM. 2"x10"
TIMBER DECKING
61" x 14" TIMBER
STRINGERS
United States Department of Agriculture Forest Service
EASTERN REGION
3.0' 3.0' 3.0'
EXISTING TYPICAL SECTION (STA 9+40 - STA 9+90)
SCALE: NTS
EXISTING BRIDGE SECTION
SCALE: NTS
PROJECT NAME
PINCUSHION MOUNTAIN
LOOP TRAIL BRIDGE #6
REPLACEMENT@ MP 0.545
7.0' LANE
6.5' LANE
EX GRADE
EX BASE - GRAVEL/ SILTY SAND
13.0' DECK O-O
12.0' CLEAR ROADWAY
6.0' 6.0'
PROPOSED ℄ GRADE
6"x6" TIMBER CURB 3"x6" TIMBER
SCUPPER
12" THICK
LONGITUDINAL
DOWEL-LAM DECK
WITH SHIPLAP
JOINTS
SUPERIOR
NATIONAL FOREST
GUNFLINT
RANGER DISTRICT
EXISTING TYPICAL SECTION (STA 10+10 - STA 10+80)
SCALE: NTS
PROPOSED BRIDGE SECTION
SCALE: NTS
13.4' PAY LIMITS OF AGGREGATE BASE,
GRADING D, COMPACTION METHOD B
12.0' ℄ SEEDING, DRY METHOD ROLLED EROSION CONTROL PRODUCT,
DRAWING TITLE
TYPICAL
CLEARING AND GRUBBING,
DISPOSAL METHOD A
(ONLY MINIMUM AS REQUIRED
FOR CONSTRUCTION, TYP.)
ROADWAY EXCAVATION,
COMPACTION METHOD B
1.0'
6.0' 6.0'
PLAN GRADE
AGGREGATE BASE,
GRADING D, COMPACTION
METHOD B
(6")
TYPE 2.D WITH NATURAL NETTING (TYP)
PLACING CONSERVED TOPSOIL, 3-INCH (TYP)
EMBANKMENT, CIP
6"
(AVERAGE) SPILLWAY,
SAME WIDTH
AS DITCH BOTTOM
RIPRAP, CLASS 0,
MACHINE PLACED
(INCIDENTAL)
DATE
ARCHIVE NO.
SECTIONS
PROPOSED TYPICAL SECTION (STA 9+40 - STA 9+86.25)
SCALE: NTS
EXISTING
GROUND
18" DESIGNER DWG SHEET NO.
SEEDING, DRY METHOD
ROLLED EROSION CONTROL PRODUCT,
13.4' PAY LIMITS OF AGGREGATE BASE,
GRADING D, COMPACTION METHOD B
12.0'
℄ EXISTING
C.SMITH
DRAWN
TYPE 2.D WITH NATURAL NETTING (TYP)
PLACING CONSERVED TOPSOIL, 3-INCH (TYP)
EMBANKMENT, CIP
6.0' 6.0'
PLAN GRADE
AGGREGATE BASE,
1.0'
GROUND
CLEARING AND GRUBBING,
DISPOSAL METHOD A
(ONLY MINIMUM AS REQUIRED
FOR CONSTRUCTION, TYP.)
ROADWAY EXCAVATION,
DITCH BOTTOM 1'-0" MIN.
1'-0" MIN.
FLOW
J.ALLEN
CHECKED
G.JUNTTILA
GRADING D, COMPACTION
METHOD B
(6")
COMPACTION METHOD B
SIDE VIEW SHOWING CHECK DAM PROJECT NO.
SHEET 4 OF
PROPOSED TYPICAL SECTION (STA 10+13.75 - STA 10+80)
SCALE: NTS
PROPOSED CHECK DAM DETAIL
SCALE: NTS
U28-02592
VARIES
CP
1161.8
REBAR WITH CAP
GENERAL NOTES: HORIZONTAL AND VERTICAL CONTROL LEGEND
1. INSTALL THE SPECIFIED QUANTITY OF ROLLED EROSION CONTROL PRODUCT (EMAT) AND
THEN ANY ADDITIONAL AREAS THAT ARE DISTURBED BY THE CONTRACTOR SHALL BE GSOC POINT
CP4
LOCATION
STA / OFFSET NORTHING EASTING
9+22.08 / 11.38' RT 805865.4404 3312001.4999
ELEVATION DESCRIPTION
1152.17 REBAR WITH CAP
BENCHMARK CONTROL POINT
2. COORDINATE SYSTEM REFERS TO NAD83 MINNESOTA STATE PLANES, NORTH ZONE. DATUM
REFERS TO NAVD88.
3. REFERENCE POINTS "A" AND "B" REFER TO FINISH GRADE AT CENTERLINE AT THE ENDS OF
THE PROPOSED BRIDGE SLAB.
4. PROVIDE SMOOTH TRANSITION FROM EXISTING TO PROPOSED TRAIL AT REFERENCE
POINTS "C" AND "D". FADE OR EXTEND PROFILE SLIGHTLY AS REQUIRED.
GOPHER STATE ONE CALL BM1 9+84.34 / 34.55' LT 805942.7515 3312026.0311 1155.36 BM IN 9" FIR
RIPRAP
RIGHT OF WAY
TREE LINE
EDGE OF GRAVEL
EDGE OF BIT
SILT SOCK United States Department of Agriculture
Forest Service
5. SURVEY WAS COMPLETED BY UPEA FOR THIS PROJECT ON 11-22-2022.
6. ALL TREE REMOVAL TO BE INCIDENTAL TO CLEARING AND GRUBBING, DISPOSAL METHOD A.
PROPERTY OWNER:
SUPERIOR
NATIONAL FOREST
AGGREGATE BASE (6" DEPTH)
0 10 20 Feet
EASTERN REGION
CONSTRUCTION &
SURVEY CENTERLINE
PC STA = 9+52.13
N = 805894.7612
E = 3312015.3259
PI STA = 9+69.39
N = 805906.7972 E = 3312027.7037
PT STA = 9+86.25
N = 805913.4404
E = 3312043.6394 = 21.57
R = 90.65' T = 17.26'
BM1
PROPERTY OWNER:
SUPERIOR
NATIONAL FOREST
PROPOSED RIPRAP,
CLASS II, MACHINE
PLACED (TYP) 37
EXISTING TREE LINE
EXISTING EDGE OF
WATER
SILT SOCK (TYP)
12'
P.O.E.
REF PT "D"
CP5
PROJECT NAME
PINCUSHION MOUNTAIN
LOOP TRAIL BRIDGE #6
REPLACEMENT@ MP 0.545
SUPERIOR
NATIONAL FOREST
PROPOSED
AGGREGATE BASE,
GRADING D,
COMPACTION METHOD B
P.O.B.
REF PT "C"
L = 34.12'
12'
REF PT "A" 10+00 N67° 22' 11"E
27.50'
13 13
REF PT "B" CLEARING AND GRUBBING,
DISPOSAL METHOD A (TYP)
PROPOSED SLOPE STAKE LINE
(TYP)
PC STA = 10+13.75
N = 805924.0220 E = 3312069.0220
PI STA = 10+46.16
N = 805936.4925
GUNFLINT
RANGER DISTRICT
DRAWING TITLE
CP4
EXISTING TREE LINE
EXISTING EDGE OF WATER
EXISTING STRUCTURE
(TO BE REMOVED)
E = 3312098.9361
PT STA = 10+76.96
N = 805962.6556 E = 3312118.0633 = 31.20
PLAN OF SITE
PROPERTY OWNER:
SUPERIOR
NATIONAL FOREST
R = 116.08' T = 32.41' L = 63.21'
SOIL EROSION CONTROL REQUIREMENTS
KEY DETAIL CHARACTERISTICS
DATE
PC STA = 8+24.82
N = 805820.9132 E = 3311913.2271
PI STA = 8+68.52
N = 805835.5339 E = 3311954.4161
PT STA = 9+10.88
N = 805866.0035 E = 3311985.7512
= 24.65 R = 200.00' T = 43.71' L = 86.06'
PROPERTY OWNER:
SUPERIOR
NATIONAL FOREST
1155 6 SEEDING WITH
MATTING
14 AGGREGATE COVER
37 CHECK DAM CAN BE CONSTRUCTED ACROSS DITCHES OR ANY AREA
OF CONCENTRATED FLOW. A CHECK DAM IS INTENDED TO
REDUCE WATER VELOCITIES AND CAPTURE SEDIMENT.
A CHECK DAM IS NOT A FILTERING DEVICE.
ARCHIVE NO.
DESIGNER
C.SMITH
DRAWN
J.ALLEN
CHECKED
G.JUNTTILA
DWG SHEET NO.
1140 GENERAL PLAN OF SITE 54 PROJECT NO.
U28-02592
SHEET 5 OF
SEEDED UNDER THE LUMP SUM PAY ITEM.
1151.62 3312119.8586 805965.1112 10+80.00 D
1151.23 3312006.6307 805886.3062 9+40.00 C
1147.57 3312069.0220 805924.0220 10+19.25 B
1147.71 3312043.6394 805913.4404 9+86.25 A
EASTING NORTHING STATION ELEVATION
LOCATION
POINT
REFERENCE POINTS
FILTERS AND DETAINS RUNOFF. SILT SOCK
STABILIZES SOIL SURFACE THUS MINIMIZING EROSION.
PERMITS CONSTRUCTION TRAFFIC IN ADVERSE
WEATHER. MAY BE USED AS PART OF PERMANENT BASE
CONSTRUCTION OF PAVED AREAS.
USED WHERE VEGETATION IS NOT EASILY ESTABLISHED.
EFFECTIVE FOR HIGH VELOCITIES OR HIGH
CONCENTRATIONS. PERMITS RUNOFF TO INFILTRATE
SOIL. DISSIPATES ENERGY FLOW AT SYSTEM OUTLETS.
RIPRAP, RUBBLE,
GABIONS
FACILITATES ESTABLISHMENT OF VEGETATIVE COVER.
EFFECTIVE FOR DRAINAGEWAYS WITH LOW VELOCITY.
EASILY PLACED IN SMALL QUANTITIES BY INEXPERIENCED
PERSONNEL. SHOULD INCLUDE PREPARED TOPSOIL BED.
EROSION MAT WITH NETTING IS PROHIBITED.
PROPOSED
STRUCTURE
STA. 10+00
P T:
+8
6.
P C
: 1 0+
.7
11+26.90 / 13.09' RT 805995.2638 3312158.1126 PROPOSED EXISTING
1158 1158
1157 1157
1156 1156 United States Department of Agriculture
Forest Service
1155 1155
1154 1154
EASTERN REGION
REF PT "C"
P.O.B.
MATCH EXISTING
PROPOSED ROAD PROFILE AT CL
EXISTING ROAD PROFILE AT CL
LOW PT STA: 9+86.25
LOW PT ELEV: 1147.71
PVI STA: 9+74.63
PVI ELEV: 1147.77
G.C.: 9.49% K: 2.44
LVC: 23.18
LOW PT STA: 10+16.11
LOW PT ELEV: 1147.57
PVI STA: 10+38.31
PVI ELEV: 1147.45
G.C.: 10.50% K: 4.67
LVC: 49.01
6"x6"x27'-6" TIMBER CURB
3"x6"x4'-71" SCUPPER
(TYP.)
EMBANKMENT, CIP
REF PT "D"
P.O.E.
MATCH EXISTING
PROJECT NAME
PINCUSHION MOUNTAIN
LOOP TRAIL BRIDGE #6
REPLACEMENT@ MP 0.545
SUPERIOR
NATIONAL FOREST
GUNFLINT
RANGER DISTRICT
REF PT "A"
24.00' CHANNEL
REF PT "B"
PROP. LOW CHORD = 1146.58'
DRAWING TITLE
PROFILE OF SITE
1145 1145
DATE
Q100 WSE = 1143.58'
ARCHIVE NO.
EXISTING BRIDGE (TO BE REMOVED):
18 FOOT (OVERALL LENGTH) SINGLE SPAN
TIMBER GIRDER PEDESTRIAN TRAIL BRIDGE
ON TIMBER SILL ABUTMENTS.
PROPOSED BRIDGE, CL STA 10+00:
27.5 FOOT (OVERALL LENGTH) SINGLE SPAN,
DOWEL-LAM SLAB BRIDGE WITH TIMBER CRIB
FOUNDATIONS.
1142.21
EXISTING PROFILE ELEVATION AT CL
PROPOSED PROFILE ELEVATION AT CL
1142.08
OBS WSE = 1142.17'
11-22-2022
STREAM BED
EL 1141.81' (+/-)
GENERAL PROFILE
0 10 20
Feet (HORIZONTAL) 0 1 2
Feet (VERTICAL)
DESIGNER
C.SMITH
DRAWN
J.ALLEN
CHECKED
G.JUNTTILA
DWG SHEET NO.
8+75 9+00 9+50 10+00 10+50 11+00 11+25
PROJECT NO.
U28-02592
SHEET 6 OF
.2
.4
.7
.2
.9
B V
C S
: 9 +6
3.
B
V C
E : 1
8.
.0
.0
E V
C S
: 9 +8
E
V C
E : 1
7.
.6
.1
B V
C S
: 1 0+
.7
B
V C
E : 1
7.
.6
.8
.8
.0
E V
C S
: 1 0+
.7
E
V C
E : 1
9.
.1
.0
.5
.5
GSOC
GOPHER STATE ONE CALL
PROPOSED RIPRAP, CLASS
II, MACHINE PLACED (TYP)
PROPOSED CHECK DAMS
(TYP)
EXISTING TREE LINE
13'-1" (MAX.)
SILT SOCK
(TYP)
PROPOSED SLOPE STAKE LINE
(TYP)
EXISTING EDGE OF WATER
13'-6"
8'-9" (MAX.)
0 4 8 Feet
United States Department of Agriculture Forest Service
PROPOSED
AGGREGATE BASE, GRADING D,
COMPACTION METHOD B
OBJECT MARKERS,
CARSONITE, HIGH
INTENSITY REFLECTIVITY
REF PT "A"
13'-0"
DECK
O-O
3'-0"
12'-0"
CLEAR
PROPOSED
STRUCTURE
STA. 10+00
3'-0" 5'-3"
OBJECT MARKERS,
CARSONITE, HIGH
INTENSITY
REFLECTIVITY
12'-0"
PROPOSED
AGGREGATE
WEIGHT LIMITS
SIGN (R12-1)
(20 TON)
EASTERN REGION
PROJECT NAME
CONSTRUCTION &
SURVEY CENTERLINE
STA: 9+86.25
(END OF BRIDGE SLAB)
23° SKEW
10+00
B
N67° 22' 11"E
27.50' REF PT "B"
STA: 10+13.75
(END OF BRIDGE SLAB)
BASE, GRADING D,
COMPACTION
METHOD B
(TYP)
PINCUSHION MOUNTAIN
LOOP TRAIL BRIDGE #6
REPLACEMENT@ MP 0.545
WEIGHT LIMITS
SIGN (R12-1)
(20 TON)
OBJECT MARKERS,
CARSONITE, HIGH
INTENSITY REFLECTIVITY
SILT SOCK (TYP)
EXISTING TREE LINE
EXISTING EDGE OF WATER
8'-9" (MAX.)
12'-1"
3'-0"
C-09
3'-0"
13'-1" (MAX.)
EXISTING STRUCTURE
(TO BE REMOVED)
OBJECT MARKERS, CARSONITE,
HIGH INTENSITY REFLECTIVITY
PROPOSED
RIPRAP, CLASS II, MACHINE PLACED
(TYP)
CLEARING AND
GRUBBING, DISPOSAL
METHOD A (TYP)
SUPERIOR
NATIONAL FOREST
GUNFLINT
RANGER DISTRICT
BRIDGE PLAN
NOTE:
1. DOWEL-LAM SLAB DECK, SPREADER BEAMS, CURB, SCUPPER, AND ALL HARDWARE TO
BE INCLUDED WITH: TREATED STRUCTURAL TIMBER, SUPERSTRUCTURE.
DRAWING TITLE
PLAN
OF
STRUCTURE
1150 PROPOSED GRADE STA. 9+73
27'-6"
TREATED STRUCTURAL
6"x6"x27'-6" TIMBER CURB 3"x6"x4'-71" SCUPPER
2. TIMBER SILL, CRIBBING, AND ALL ASSOCIATED HARDWARE TO BE INCLUDED WITH:
TREATED STRUCTURAL TIMBER, SUBSTRUCTURE.
3. FILL IN CRIBBING SHALL BE RIPRAP, CLASS 0, MACHINE PLACED.
ABUT "A"
1145.71
NOTE: FOR RIPRAP ALONG SIDES OF
CHANNEL, EXCAVATE EXISTING SOILS
DOWN TO PROPOSED BOTTOM OF RIPRAP.
RIPRAP DEPTH MAY BE REDUCED IF
BEDROCK IS ENCOUNTERED.
PER PLAN
3'-2" MIN.
DATE
ARCHIVE NO.
AGGREGATE BASE,
GRADING D,
COMPACTION METHOD B
REF PT "A"
TIMBER, SUPERSTRUCTURE
STRUCTURE EXCAVATION
(TYP.) REF PT "B" STA. 10+27
AGGREGATE BASE, GRADING D,
1 COMPACTION METHOD B
ABUT "B"
1145.57 FLAT EXISTING GROUND
AT TOE
DESIGNER
C.SMITH
DWG SHEET NO.
1145 (6")
EMBANKMENT, CIP
1.5
LIMITS OF:
STRUCTURE EXCAVATION 1142.21 5'-0"
1.5
1.5 1142.08
1.5 (6")
EMBANKMENT, CIP
1'-9"
1'-9"
DRAWN
J.ALLEN
AND STRUCTURAL BACKFILL
(TYP.) PROPOSED
RIPRAP, CLASS II,
MACHINE PLACED
(TYP)
STREAM BED
EL 1141.81' (+/-)
Q100 WSE = 1143.58'
OBS WSE = 1142.17'
11-22-2022
TREATED STRUCTURAL TIMBER, SUBSTRUCTURE
PROP. LOW CHORD = 1146.58'
RIPRAP, CLASS
II, MACHINE
PLACED
1'-9"
2'-9" CHECKED
G.JUNTTILA
BRIDGE ELEVATION RIPRAP DETAIL
SCALE: NTS
PROJECT NO.
U28-02592
SHEET 7 OF
P T:
+8
P C
: 1 0+
.7
2'-0"
BRIDGE DECK
3/4"Ø X 20" HD. DR. SPIKE
(8" EMBED)
3/4"Ø X 20" HD. DR. SPIKE
(8" EMBED)
GEOTEXTILE, TYPE III, CLASS I
(BACK FACE OF SILL AND CRIBBING ONLY)
ATTACH THE SILL TO EACH MEMBER IN THE
TOP ROW OF THE TRANSVERSE CRIBBING
United States Department of Agriculture Forest Service
EASTERN REGION
4'-6"
2'-6"
2'-6"
2'-0"
67° 113°
REF. PT. 'A' & 'B'
TIMBER SILL
TIMBER BLOCK
3" x 12" ACROSS FULL WIDTH OF
TIMBER FOUNDATION (TYP.)
2'-6"
WITH 3/4"Ø x 16" DRIFT PIN
CRIBBING SHALL BE FILLED
WITH RIPRAP, CLASS 0,
MACHINE PLACED
SOLID ROUGH SAWN TIMBER
(6" x 6" x 18')
SOLID ROUGH SAWN TIMBER
(6" x 6" x 30") 11/16"Ø HOLE IN ALL 6" x 6"
CRIBBING FOR #6 GALVANIZED
COATED REBAR AT ALL
CRIBBING INTERSECTIONS
PROJECT NAME
PINCUSHION MOUNTAIN
LOOP TRAIL BRIDGE #6
REPLACEMENT@ MP 0.545
4'-0" 2'-0" 2'-0" 1'-0" 1'-0" 2'-0" 2'-0" 4'-0" (1) 3/4"Ø x 7" DM. HD. DR. SPIKE
4'-6" SUPERIOR
18'-0"
TIMBER CRIBBING ABUTMENT PLAN
SCALE: NTS
12'-0" CLEAR ROADWAY
6'-0" 6'-0"
@ EACH BLOCK (TYP.)
TIMBER CRIBBING ABUTMENT SECTION A-A
SCALE: NTS
NATIONAL FOREST
GUNFLINT
RANGER DISTRICT
A
TRAIL SIDE
SLOPE
10" x 10" x 1'-6" TIMBER BLOCK
(2) 3/4"Ø x 16" DM. HD. DR. SPIKE
@ EACH BLOCK
12" x 12" x 18' TIMBER SILL
DRAWING TITLE
ABUTMENT PLAN
AND ELEVATION
TRAIL SIDE SLOPE
REBAR
EMBED. 4"
(TYP.)
A
(36) 3/4"Ø x 7" DM. HD. DR. SPIKE @ EACH TRANSVERSE ROUGH SAWN 6" x 6" TIMBER
TRANSVERSE CRIBBING @ 2'-0" MAXIMUM (EQUAL SPA. @ 1'-9" = 17'-6")
18'-0"
A TIMBER CRIBBING ABUTMENT ELEVATION
ROUGH SAWN 6"x6" TIMBER
CRIBBING SHALL BE FILLED WITH
RIPRAP, CLASS 0, MACHINE PLACED
(HAND TAMP RIPRAP FILL IN
CONJUNCTION WITH CONSTRICTION
OF CRIBBING IN APPROX. 6" LIFTS
LONGITUDINAL CRIBBING
3" x 12" ACROSS FULL WIDTH OF
TIMBER FOUNDATION
11/16"Ø HOLE IN ALL 6" x 6"
CRIBBING FOR #6 GALVANIZED
COATED REBAR AT ALL
CRIBBING INTERSECTIONS
(1) 3/4"Ø x 7" DM. HD. DR. SPIKE
@ EACH BLOCK
NOTES:
1. TIMBER SILL, CRIBBING, ALL ASSOCIATED HARDWARE, AND STEEL
REINFORCEMENT TO BE INCLUDED WITH: TREATED STRUCTURAL TIMBER,
SUBSTRUCTURE.
2. CONSTRUCT TIMBER CRIBBING WITH 6" x 6" ROUGH SAWN TREATED
TIMBERS. FIELD DRILLED HOLES SHALL BE TREATED WITH COPPER
NAPTHENATE.
3. THE ENGINEER MUST APPROVE THE SUBGRADE PRIOR TO INSTALLATION
OF THE TIMBER CRIBBING.
4. THE TOTAL WEIGHT OF GALVANIZED COATED #6 BARS IS 287 POUNDS
(INCLUDES BOTH ABUTMENTS).
DATE
ARCHIVE NO.
DESIGNER
C.SMITH
DRAWN
J.ALLEN
CHECKED
DWG SHEET NO.
SCALE: NTS (NORMAL TO FRONT FACE) G.JUNTTILA
PROJECT NO.
U28-02592
SHEET 8 OF
"X
TI
M
BE
R
S
IL
L 3'
-6 " T
IM
B
E R
C R
IB
BI
N G
"X
TI
M
BE
R
SI
LL
3' -6
" T
IM
B E
R C
R
IB
BI
N
G
12'-0" CLEAR ROADWAY
6'-0" 6'-0" 4'-6" PANEL "A"
13'-0" OUT TO OUT DECK
4'-0" PANEL "C" 4'-6" PANEL "B"
3/4" EYEBOLTS ARE IN PLACE ON PANEL @ SPREADER
BEAM LOCATIONS WHEN SHIPPED & ARE USED FOR
4"
SPLICE
4"
SPLICE
LIFTING & PLACING PANELS ON THE BRIDGE. REMOVE
EYEBOLTS & REPLACE WITH 3/4" x 22" DM. HD. BOLTS WITH
(1) 3"x3"x5/16" ⅊ WASHER & (1) 3/4" LOCK NUT PER BOLT, 3/4" x 20" DM. HD. DR. SPK.
1 DECK TO CAP, (TYP.)
FLAT FLAT
6" x 6" CURB, S1S1E 3" x 6" SCUPPER, S1S1E SHOP
DRILL
5/8"Ø x 11" DM. HD. DR.
SPK. @ PANEL SHIPLAP
JOINT, (TYP.) 1
FIELD DRILL 2
AFTER SPREADER BEAM HAS BEEN FIELD DRILLED 1 3 United States Department of Agriculture Forest Service
1'-6" 1'-6" 1'-6" 1'-6" 1'-6" 1'-6" 12" x 12"
TIMBER SILL
8"
6"
(TYP.) 3 SPA @ 12" = 3'-0" 6" 3 SPA @ 12" = 3'-0" 6"
6" 6"
3 SPA @ 12" = 3'-0" 6"
4" x 12" FLOORING, S1S
6" x 8" x 12'
SPREADER BEAM
6"
(TYP.)
EASTERN REGION
PROJECT NAME
SECTION THRU DECK AT ABUTMENT
SCALE: NTS
A
6" x 6" CURB, S1S1E, SECTION THRU DECK AT SPREADER BEAM
SCALE: NTS
Ø4"
Ø7/8" (MIN.)
SAE 1010 HOT-ROLLED CARBON
STEEL (SAE J412)
± 5/16" THICK
PINCUSHION MOUNTAIN
LOOP TRAIL BRIDGE #6
REPLACEMENT@ MP 0.545
SUPERIOR
NATIONAL FOREST
4"Ø SPLIT RINGS, CURB
TO SCUPPER, SCUPPER
TO DECK, SHOP DRILL
CURB & SCUPPER,
FIELD DRILL DECK
SHOP DRILL
3" x6" SCUPPER, S1S1E, SHOP DRILL
6"
A
9" NELSON 8"
COMPOSITE
SHIMS FULL
WIDTH OF BOARD
SPREADER BEAM
NELSON 8"
COMPOSITE
SHIMS (TYP)
#8x 1 1/2"
12" DECK
12" DECK
SPREADER
CURBS ARE TO BE PLACED
SO TAGS SHOW FROM ℄ OF
ROADWAY. MATCH CURBS &
SCUPPERS PER SHOP
PLACED TAG NUMBERS
4"Ø WASHER
TAGS
3/4"x23" DM. HD. BOLT (A449) WITH (1) 4"x4"x5/16" ⅊ WASHER
(UNDER NUT) & (1) 4"Ø WASHER
(UNDER HEAD) PER BOLT, CURB
TO DECK, FIELD DRILL DECK 4
4"Ø SPLIT RING
CONNECTORS
6"x6" CURB, S1S1E
3"x6"x3'-0" SCUPPER, S1S1E (TYP.)
12" DECK
GUNFLINT
RANGER DISTRICT
DRAWING TITLE
STRUCTURE DETAILS
3/4"x22" DM. HD. BOLT (A449) WITH (1) COATED DECK BEAM NOTE: 6" 8" 8" 6"
4"x4"x5/16" ⅊ WASHER (UNDER NUT) & (1)
4"Ø WASHER (UNDER HEAD) PER BOLT,
CURB TO DECK, FIELD DRILL DECK 4
SCREW (TYP) CONTRACTOR IS TO ASSEMBLE CURB & SCUPPER IN PLACE,
MARK & DRILL THRU DECK, DISASSEMBLE, GROOVE DECK FOR
SPLIT RINGS, REASSEMBLE & BOLT DOWN. DATE
SECTION AT CURB
SCALE: NTS
SHIMMING DETAIL
SCALE: NTS
CURB & SCUPPER ASSEMBLY (A-A)
SCALE: NTS
NOTES: 27'-6"
1 1 6'-101" 1
ARCHIVE NO.
1 ALL HARDWARE PENETRATING THE TOP OR BOTTOM EDGE OF THE DECK PLANK SHALL PASS THROUGH THE CENTER OF THAT
DIMENSION.
2 FIELD DRILLED HOLES IN THE LOWER SPLICE BLOCK OF EACH PANEL ARE TO BE DRILLED COMPLETELY THROUGH THE BLOCK TO
PREVENT SPLITTING WHEN INSTALLING THE 5/8" DRIVE SPIKES.
3 THE CONTRACTOR SHALL INSTALL NELSON 8" COMPOSITE SHIMS OR EQUAL (SUPPLIED BY BRIDGE MANUFACTURER) IN ALL LOCATIONS WHERE THE TOP OF THE SPREADER BEAM DOES NOT CONTACT THE BOTTOM OF THE DECK PANEL UPON TIGHTENING TO ENSURE SNUG FIT ACROSS ENTIRE DECK WIDTH. THE CONTRACTOR SHALL RE-TIGHTEN ALL NUTS ON THE LAST DAY OF CONSTRUCTION IN THE PRESENCE OF THE ENGINEER TO ENSURE ALL NUTS ARE PROPERLY TIGHTENED. SET THREADS ON ALL
BOLTS AT NUT WITH A CENTER PUNCH AFTER TIGHTENING.
4 HIGH STRENGTH (A449) DOME HEAD BOLTS DO NOT HAVE FINS UNDER THE HEAD AT THE SHANK.
5/8"Ø x 11" DM. HD. DR. SPK.
@ 24" SPA. (TYP. @ SHIPLAP JT.)
23°
4'-12" 6'-10 2" 2
SPREADER BEAM
9'-72"
DESIGNER
C.SMITH
DRAWN
J.ALLEN
CHECKED
G.JUNTTILA
DWG SHEET NO.
ALL TIMBER AND HARDWARE SHOWN SHALL BE PAID FOR AS: TREATED STRUCTURAL TIMBER, SUPERSTRUCTURE.
CONTRACTOR SHOULD BE AWARE OF THE POTENTIAL TO HIT THE R.S. NAILS IN THE PREFABRICATED DECK PANELS WHEN INSTALLING THE CURB BOLTS FOR THE CURB & SCUPPER ATTACHMENT. A 3/4" HOLE SAW IS RECOMMENDED IN DRILLING
THROUGH THE R.S. NAILS FOR THIS ATTACHMENT.
BRIDGE PLAN
SCALE: NTS
PROJECT NO.
U28-02592
SHEET 9 OF
B
Forest Service
EASTERN REGION
ABBREVIATIONS (PLAN):
PROJECT NAME
PINCUSHION MOUNTAIN
LOOP TRAIL BRIDGE #6
REPLACEMENT@ MP 0.545
R12-1 SIGN
SIGNS, TYPE III SHEETING
1'-0"
WEIGHT
LIMIT
TONS
1'-3"
6'-6"
LPSM - LUMP SUM
LNFT - LINEAR FEET
CUYD - CUBIC YARD
SQYD - SQUARE YARD
EA - EACH
LBS - POUNDS
EX - EXISTING
PROP - PROPOSED
NTS - NOT TO SCALE
TYP - TYPICAL
CL - CENTER LINE
CIP - COMPACTED IN PLACE
P.O.B. - POINT OF BEGINNING
P.O.E. - POINT OF ENDING
REF PT - REFERENCE POINT
OHWM - ORDINARY HIGH WATER MARK
OBS WSE - OBSERVED WATER SURFACE ELEVATION
Q100 WSE - 100 YEAR FLOOD WATER SURFACE ELEVATION
F.F. - FRONT FACE
B.F. - BACK FACE
SPA - SPACES
ABUT - ABUTMENT
PL - PLATE
GALV - GALVANIZED
U.N.O. - UNLESS NOTED OTHERWISE
SUPERIOR
NATIONAL FOREST
GUNFLINT
RANGER DISTRICT
DRAWING TITLE
QUANTITIES &
MISCELLANEOUS
POST, STEEL, 3 LB
(10 FEET)
EXISTING GROUND
(MAX.)
5'-3"
42" (MIN.)
2'-2"
INSIDE EDGE OF
BRIDGE RAIL OR
TRAVEL WAY
37"
CARSONITE
TOP OF
STRUCTURE/
GRND
6'-0"
2'-2"
2'-6"
1'-4"
OBJECT MARKERS, CARSONITE,
HIGH INTENSITY REFLECTIVITY
BEGIN/END
STRUCTURE
TOP OF ROAD
DATE
ARCHIVE NO.
DESIGNER
C.SMITH
DRAWN
J.ALLEN
DETAILS
DWG SHEET NO.
STEEL POST SIGN DETAIL
SCALE: NTS
OBJECT MARKER
SCALE: NTS
2'-0"
CHECKED
G.JUNTTILA
PROJECT NO.
U28-02592
SHEET 10 OF
SUMMARY OF PROJECT QUANTITIES
ITEM NO. DESCRIPTION UNITS QUANTITY
15101 MOBILIZATION LPSM 1
15201 CONSTRUCTION SURVEY AND STAKING, METHOD 1, TOLERANCE CLASS C LPSM 1
15702 SILT SOCK LNFT 75
15711 CHECK DAMS EACH 5
20102 CLEARING AND GRUBBING, DISPOSAL METHOD A ACRE 0.003
20304 REMOVAL OF OLD STRUCTURE, DISPOSAL METHOD A LPSM 1
20401 ROADWAY EXCAVATION, COMPACTION METHOD B CUYD 32
20411 EMBANKMENT, CIP CUYD 6
20801 STRUCTURE EXCAVATION CUYD 107
20803 STRUCTURAL BACKFILL CUYD 64
25101 RIPRAP, CLASS 0, MACHINE PLACED CUYD 5
25101.1 RIPRAP, CLASS II, MACHINE PLACED CUYD 20
25116 GEOTEXTILE, TYPE III, CLASS I SQYD 26
30103 AGGREGATE BASE, GRADING D, COMPACTION METHOD B CUYD 28
55704 TREATED STRUCTURAL TIMBER, SUPERSTRUCTURE LPSM 1
55706 TREATED STRUCTURAL TIMBER, SUBSTRUCTURE LPSM 1
62403 PLACING CONSERVED TOPSOIL, 3-INCH SQYD 94
62503 SEEDING, DRY METHOD LPSM 1
62901 ROLLED EROSION CONTROL PRODUCT, TYPE 2.D WITH NATURAL NETTING SQYD 94
63301 SIGNS, TYPE III SHEETING SQFT 3
63306 POST, STEEL, 3 LB LNFT 20
63307 OBJECT MARKERS, CARSONITE, HIGH INTENSITY REFLECTIVITY EACH 4
63501 TEMPORARY TRAFFIC CONTROL LPSM 1
| United States Department of Agriculture Forest Service |
| STEPHEN POPKOWSKI |
| PROJECT SITE |
| PROJECT LOCATION |
| DESIGN DATA: |
| HYDRAULIC DATA: |
| GENERAL NOTES: |
| GENERAL NOTES: |
| SPECIFICATIONS: |
| CONSTRUCTION NOTES: |
| EASTERN REGION |
| GUNFLINT |
| C.SMITH |
| J.ALLEN |
| G.JUNTTILA |
| U28-02592 |
| 1 |
| EASTERN REGION |
| 2 |
| GUNFLINT |
| TRAFFIC CONTROL PLAN KEY |
| DETOUR NOTES: |
| C.SMITH |
| J.ALLEN |
| G.JUNTTILA |
| U28-02592 |
| 7.0' LANE (+/-) |
| 7.0' LANE (+/-) |
| EASTERN REGION |
| EXISTING TYPICAL SECTION (STA 9+40 - STA 9+90) |
| EXISTING BRIDGE SECTION |
| 7.0' LANE (+/-) |
| 6.5' LANE |
| EXISTING TYPICAL SECTION (STA 10+10 - STA 10+80) |
| PROPOSED BRIDGE SECTION |
| PROPOSED TYPICAL SECTION (STA 9+40 - STA 9+86.25) |
| C.SMITH |
| J.ALLEN |
| G.JUNTTILA |
| PROPOSED TYPICAL SECTION (STA 10+13.75 - STA 10+80) |
| PROPOSED CHECK DAM DETAIL |
| GENERAL NOTES: |
| GSOC |
| EASTERN REGION |
| GUNFLINT |
| SOIL EROSION CONTROL REQUIREMENTS |
| C.SMITH |
| J.ALLEN |
| G.JUNTTILA |
| GENERAL PLAN OF SITE 54 |
| U28-02592 |
| EASTERN REGION |
| GUNFLINT |
| GENERAL PROFILE |
| C.SMITH |
| J.ALLEN |
| G.JUNTTILA |
| U28-02592 |
| EASTERN REGION |
| BRIDGE PLAN |
| 1 |
| C.SMITH |
| J.ALLEN |
| BRIDGE ELEVATION |
| U28-02592 |
| EASTERN REGION |
| TIMBER CRIBBING ABUTMENT PLAN |
| TIMBER CRIBBING ABUTMENT SECTION A-A |
| GUNFLINT |
| A |
| A |
A TIMBER CRIBBING ABUTMENT ELEVATION
| NOTES: |
| C.SMITH |
| J.ALLEN |
| G.JUNTTILA |
| U28-02592 |
| EASTERN REGION |
| SECTION THRU DECK AT ABUTMENT |
| A |
| SECTION THRU DECK AT SPREADER BEAM |
| A |
| GUNFLINT |
| SECTION AT CURB |
| SHIMMING DETAIL |
| CURB & SCUPPER ASSEMBLY (A-A) |
| C.SMITH |
| J.ALLEN |
| G.JUNTTILA |
| BRIDGE PLAN |
| U28-02592 |
| EASTERN REGION |
| GUNFLINT |
| C.SMITH |
| STEEL POST SIGN DETAIL |
| OBJECT MARKER |
| G.JUNTTILA |
| U28-02592 |
| TITLE SHEET: | |
| GENERAL NOTES: | |
| TEMPORARY TRAIL CLOSURE: | |
| TYPICAL SECTIONS: | |
| PLAN OF SITE: | |
| PROFILE OF SITE: | |
| PLAN OF STRUCTURE: | |
| ABUTMENT PLAN AND ELEVATION: | |
| STRUCTURE DETAILS: | |
| EASTING: | |
| RIPRAP RUBBLE GABIONS: | |
| SILT SOCK: | |
| FILTERS AND DETAINS RUNOFF: | |
| DESCRIPTION: | |
| MOBILIZATION: | |
| SILT SOCK_2: | |
| CHECK DAMS: | |
| CLEARING AND GRUBBING DISPOSAL METHOD A: | |
| ROADWAY EXCAVATION COMPACTION METHOD B: | |
| EMBANKMENT CIP: | |
| STRUCTURE EXCAVATION: | |
| STRUCTURAL BACKFILL: | |
| RIPRAP CLASS 0 MACHINE PLACED: | |
| RIPRAP CLASS II MACHINE PLACED: | |
| GEOTEXTILE TYPE III CLASS I: | |
| TREATED STRUCTURAL TIMBER SUBSTRUCTURE: | |
| PLACING CONSERVED TOPSOIL 3INCH: | |
| SEEDING DRY METHOD: | |
| SIGNS TYPE III SHEETING: | |
| POST STEEL 3 LB: | |
| TEMPORARY TRAFFIC CONTROL: | |
| 2023-06-06T16:14:22-0500 | |
| THOMAS HALL |
| Date2_af_date: | |
| 2023-06-07T12:47:18-0500 | |
| R9 Regional Office | |
| Jeff Dulka | |
| I am approving this document |
| 2023-06-07T13:55:58-0500 | |
| JOSIAH KIM |