1104_Chittock_FURNACE_and_water_heater.docx
DOCX document 34 KB Posted
- Solicitation number
- 2025-COMMUNITY DEVELOPMENT-075
- Issued by
- Kalamazoo County, Huntington Woods City, Michigan
About this file
This document is a detailed work write-up for a residential property improvement project issued by the City of Jackson Community Development Department in Michigan. The project involves replacing the furnace and water heater at 1104 Chittock Ave in Jackson, Michigan, with specific requirements for a 95% efficient forced air gas furnace and a 40-gallon high-efficiency water heater. The work write-up specifies detailed installation standards, including compliance with Michigan Mechanical Code, proper ductwork placement, and adherence to heating and ventilation standards for all habitable rooms.
The project appears to be funded through the City of Jackson's Community Development Department, with competitive bidding sought for the replacement of these home systems. Permits are required for both the furnace and water heater installations, and the contractor must follow specific guidelines for placement, insulation, and code compliance. The work write-up includes spaces for the property owner, contractor, and a construction specialist to review and sign off on the proposed scope of work, indicating a structured approach to municipal home improvement assistance that likely supports low-income or qualifying homeowners with essential home system upgrades.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1104_Chittock_Ave_-_Replace_Furnace_and_Water_Heater.pdf | ||
| 1104_Chittock.msg | MSG file | |
| All_Services_Sample_Contract_.docx | DOCX document | |
| CDBG_Additional_Forms.pdf | ||
| Performance_Bond.pdf | ||
| Labor_and_Material_Payment_Bond.pdf | ||
| Maintenance_and_Guarantee_Bond.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Work Write-Up
F19 - FURNACE - AC- REPLACENENT.
* EXHIBIT 1 *
Dated: 9/4/2025
CUSTOMER INFORMATION
TAYLOR, DORTHEAN
1104 CHITTOCK AVE, Jackson, MI 49203
PREPARED BY
sharrison@cityofjackson.org
* NOTE *
THE CUSTOMER AND CONTRACTOR MUST SIGN THE BOTTOM OF EACH PAGE ONLY IF
1) THIS WORK WRITE-UP BECOMES PART OF A CONSTRUCTION CONTRACT
2) THE UNDERSIGNED CUSTOMER AND CONTRACTOR HAVE REVIEWED, APPROVED AND AGREED TO THE WORK AND PRICES DESCRIBED IN THIS WORK WRITE-UP
Location: Unassigned
| General Requirements |
| Quantity |
| Units |
| Total |
1 - F19 - FURNACE - REPLACE, ONLY
(Specification ID:1.19000 Estimated Qty:0)
* PERMIT REQUIRED *
Replace existing furnace with new 95% efficient forced air, gas fired furnace bearing AGA label. Furnace output capacity shall be sufficient to heat the structure according to NWAHA standards. Installations shall comply with the current Michigan Mechanical Code. All habitable rooms, as designated by the Building Inspector, shall be supplied with warm air sufficient to maintain temperatures according to NWAHA standards. All new register installations shall be located in floor or low wall with the exception of bathrooms, which shall be wall mounted. Provide an adequate means of return air for these new supply runs. The use of ceiling diffuser outlets will be allowed only with prior approval. When new supply or returns are required and duct is run through any habitable room, it shall be enclosed in new or existing walls. Any new enclosure shall match existing surfaces. Installation shall include a register in the warm air plenum or trunkline to provide heat to the cellar and a new thermostat. A filter rack with cover shall be installed in the return air duct outside of the furnace cabinet. Whenever possible, insulate new supply and return ducts in unheated attic spaces, ventilated crawl spaces, and other exposed locations to prevent excessive heat loss. Flexible duct shall be used only in attics or crawl spaces. If not bid As a separate part of this contract, the installation shall include repair or replacement of wiring and/or plumbing necessary to comply with local code. If the existing ductwork is not to be replaced, it must be approved by the Mechanical Inspector and:
| Plumbing System |
| Quantity |
| Units |
| Total |
2 - WA1 - High Efficiency unit (Specification ID:75.10000 Estimated Qty:0)
EA
* PERMIT REQUIRED *
Disconnect existing unit and remove from property. Installation of a new 40 Gal High efficiency unit.
Water heater shall be installed in accordance with the manufacturer's installation instructions. Electric water heaters shall conform to the requirements of the Michigan plumbing Code and provisions of NFPA 70. Gas-fired water heaters shall conform to the requirements of the International Fuel Gas Code. Elevation of water heater ignition sources and mechanical damage protection requirements for water heaters shall be in accordance with the IMC and the IFG codes.
Appliances shall be provided with access for inspection, service, repair, and replacement without disabling the function of a fire-resistance-rated assembly or removing permanent construction, other appliances or any other piping or ducts not connected to the appliance being inspected, service, repaired or replaced. A level working space at least 30 inches deep and 30 inches wide shall be provided in front of the control side to service an appliance.
Total
Prepared By: sharrison@cityofjackson.org on 9/4/2025
OWNER ACCEPTS SCOPE OF WORK
I have read the contents of this work write up and received a copy. I fully understand the repairs to be made to my property.
| x_________________________ | __________ | |
| Owner: | Date |
CONTRACTOR ACCEPTS SCOPE OF WORK
I have read the contents of this work write up and agree to perform all work called for in accordance with the bid submitted on __________.
| x_________________________ | __________ | |
| Contractor | Date |
| x____________________________ | __________ | |
| Construction Specialist | Date |
| Prepared By: sharrison@cityofjackson.org on 9/4/2025 |
| 4 of 4 |
image1.png
File details come from the government source that posted it. Updated .