1104_Chittock.msg
MSG file 93 KB Posted
- Solicitation number
- 2025-COMMUNITY DEVELOPMENT-075
- Issued by
- Kalamazoo County, Huntington Woods City, Michigan
About this file
This document is a Work Write-Up prepared by the City of Jackson Community Development Department in Michigan for a residential housing rehabilitation project at 1104 Chittock Ave. The project involves the removal and replacement of a furnace and water heater for homeowner Dorothean Taylor, with specific requirements for new energy-efficient units. The work includes installing a 95% efficient forced air gas furnace that complies with Michigan Mechanical Code and a 40-gallon high-efficiency water heater, both of which require permits and must meet specific installation standards.
The project appears to be part of a community development housing rehabilitation program, with the work being documented and prepared by Sven Harrison, a Housing Rehabilitation Specialist and Code Official from the Community Development Department. The work write-up includes detailed technical specifications for the furnace and water heater installations, emphasizing compliance with local building codes, energy efficiency standards, and proper installation techniques. The document is dated 9/4/2025 and includes spaces for owner and contractor acceptance of the scope of work, indicating a structured approach to managing the home improvement project.
Text of this file
1104 Chittock
| From |
| Sven Harrison |
| To |
| Kari Kerstetter |
| Cc |
| Christopher Herrmann |
| Recipients |
| KKerstetter@cityofjackson.org; cherrmann@cityofjackson.org |
Good Morning. Have a other one for you. Did a return of 10/22/25.
Owner Dorothean Taylor 517-783-6660
Thank You
Sven Harrison
Housing Rehabilitation Specialist
Code Offical & Building Inspector
Community Development Department
161 W. Michigan Ave | Jackson, MI 49201
O: (517) 768-6421 | C: (517) 414-9117 sharrison@cityofjackson.org
1104 Chittock FURNACE and water heater.docx
Work Write-Up
F19 - FURNACE - AC- REPLACENENT.
* EXHIBIT 1 *
Dated: 9/4/2025
CUSTOMER INFORMATION
TAYLOR, DORTHEAN
1104 CHITTOCK AVE, Jackson, MI 49203
PREPARED BY
sharrison@cityofjackson.org
* NOTE *
THE CUSTOMER AND CONTRACTOR MUST SIGN THE BOTTOM OF EACH PAGE ONLY IF
1) THIS WORK WRITE-UP BECOMES PART OF A CONSTRUCTION CONTRACT
2) THE UNDERSIGNED CUSTOMER AND CONTRACTOR HAVE REVIEWED, APPROVED AND AGREED TO THE WORK AND PRICES DESCRIBED IN THIS WORK WRITE-UP
Location: Unassigned
General Requirements
Quantity
Units
Total
1 - F19 - FURNACE - REPLACE, ONLY
(Specification ID:1.19000 Estimated Qty:0)
* PERMIT REQUIRED *
Replace existing furnace with new 95% efficient forced air, gas fired furnace bearing AGA label. Furnace output capacity shall be sufficient to heat the structure according to NWAHA standards. Installations shall comply with the current Michigan Mechanical Code. All habitable rooms, as designated by the Building Inspector, shall be supplied with warm air sufficient to maintain temperatures according to NWAHA standards. All new register installations shall be located in floor or low wall with the exception of bathrooms, which shall be wall mounted. Provide an adequate means of return air for these new supply runs. The use of ceiling diffuser outlets will be allowed only with prior approval. When new supply or returns are required and duct is run through any habitable room, it shall be enclosed in new or existing walls. Any new enclosure shall match existing surfaces. Installation shall include a register in the warm air plenum or trunkline to provide heat to the cellar and a new thermostat. A filter rack with cover shall be installed in the return air duct outside of the furnace cabinet. Whenever possible, insulate new supply and return ducts in unheated attic spaces, ventilated crawl spaces, and other exposed locations to prevent excessive heat loss. Flexible duct shall be used only in attics or crawl spaces. If not bid As a separate part of this contract, the installation shall include repair or replacement of wiring and/or plumbing necessary to comply with local code. If the existing ductwork is not to be replaced, it must be approved by the Mechanical Inspector and:
Plumbing System
Quantity
Units
Total
2 - WA1 - High Efficiency unit
(Specification ID:75.10000 Estimated Qty:0)
EA
* PERMIT REQUIRED *
Disconnect existing unit and remove from property. Installation of a new 40 Gal High efficiency unit.
Water heater shall be installed in accordance with the manufacturer's installation instructions. Electric water heaters shall conform to the requirements of the Michigan plumbing Code and provisions of NFPA 70. Gas-fired water heaters shall conform to the requirements of the International Fuel Gas Code. Elevation of water heater ignition sources and mechanical damage protection requirements for water heaters shall be in accordance with the IMC and the IFG codes.
Appliances shall be provided with access for inspection, service, repair, and replacement without disabling the function of a fire-resistance-rated assembly or removing permanent construction, other appliances or any other piping or ducts not connected to the appliance being inspected, service, repaired or replaced. A level working space at least 30 inches deep and 30 inches wide shall be provided in front of the control side to service an appliance.
Total
Prepared By: sharrison@cityofjackson.org on 9/4/2025
OWNER ACCEPTS SCOPE OF WORK
I have read the contents of this work write up and received a copy. I fully understand the repairs to be made to my property.
x_________________________ __________
Owner: Date
CONTRACTOR ACCEPTS SCOPE OF WORK
I have read the contents of this work write up and agree to perform all work called for in accordance with the bid submitted on __________.
x_________________________ __________
Contractor Date x____________________________ __________
Construction Specialist Date
Prepared By: sharrison@cityofjackson.org on 9/4/2025 image1.png
Other files
| File | Type | Posted |
|---|---|---|
| 1104_Chittock_Ave_-_Replace_Furnace_and_Water_Heater.pdf | ||
| 1104_Chittock_FURNACE_and_water_heater.docx | DOCX document | |
| All_Services_Sample_Contract_.docx | DOCX document | |
| CDBG_Additional_Forms.pdf | ||
| Performance_Bond.pdf | ||
| Labor_and_Material_Payment_Bond.pdf | ||
| Maintenance_and_Guarantee_Bond.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .