A1.05

VA SPECIFIC

GENERAL

NOTES

MSW

RCW

REVISIONS

ALIGNED

STUDIO, LLC

ARCHITECTURE + DESIGN

MISSOURI CERTIFICATE OF AUTHORITY

No. 2016030702

DRAWN BY:

REVIEWED BY:

13100 MANCHESTER

JOB NO.

DATE:

CONTACT:

314.317.0060

SUITE 225

ST. LOUIS, MO 63131

www.aligned-studio.com

OF

CO

NS

TR

UC

TIO

N

DO

CU

ME

NT

S

FO

R:

DE

PA

RT

ME

NT

O

F

VE

TE

RA

NS

' A

FF

AIR

S

RE

AD

JU

ST

ME

NT

C

OU

NS

EL

IN

G

SE

RV

ICE

S

NO

RT

H

OU

TE

R

TO

W N

AN

D

CO

UN

TR

Y, MI

SSO

UR

I 6

MICKI WEHMEIER

micki@aligned-studio.com

RANDY WINZEN

randy@aligned-studio.com

1720.1

11.01.17

S

S S

S

S S

S

S

J

T

S

+44

+44 +44

S

S

S

S

S

S

S

S

S

S

S

SSS

S

T

FE

FE

T

T

T

T

+44

+44

+44

+44

DED

J

J +81

EP

REVISIONS

ALIGNED

STUDIO, LLC

ARCHITECTURE + DESIGN

MISSOURI CERTIFICATE OF AUTHORITY

No. 2016030702

DRAWN BY:

REVIEWED BY:

13100 MANCHESTER

JOB NO.

DATE:

CONTACT:

314.317.0060

SUITE 225

ST. LOUIS, MO 63131

www.aligned-studio.com

OF

CO

NS

TR

UC

TIO

N

DO

CU

ME

NT

S

FO

R:

DE

PA

RT

ME

NT

O

F

VE

TE

RA

NS

' A

FF

AIR

S

RE

AD

JU

ST

ME

NT

C

OU

NS

EL

IN

G

SE

RV

ICE

S

NO

RT

H

OU

TE

R

TO

W N

AN

D

CO

UN

TR

Y, MI

SSO

UR

I 6

MICKI WEHMEIER

micki@aligned-studio.com

RANDY WINZEN

randy@aligned-studio.com

1720.1

11.01.17

A2.00

DEMOLITION PLAN

& DOOR DETAILS

RCW

RCW

PARTIAL SECOND FLOOR DEMOLITION PLAN

SCALE: 1/8"=1'-0"

DEMO/REMOVE EXISTING PARTITION INCLUDING ALL ELECTRICAL/ DATA WIRING/CABLING BACK TO ITS

SOURCE PANEL.

DEMO/REMOVE EXISTING DOOR AND FRAME AS REQUIRED. SALVAGE FOR REUSE IN NEW DESIGN, TURN

OVER TO BUILDING STOCK OR DISPOSE OF AS DIRECTED BY OWNER.

DEMO/REMOVE EXISTING GLASS BORROW LIGHT AND FRAME (WHERE APPLICABLE).

REMOVE EXISTING CEILING TILE AND GRIDS IN HATCHED AREA. PROVIDE SUPPORT TO ANY GRIDS TO

REMAIN AND PREPARE FOR NEW PARTITIONS TO BE ERECTED.

DEMO/REMOVE EXISTING SHELVING, CASEWORK AND COUNTERTOPS INCLUDING ALL ELECTRICAL/ DATA

WIRING/CABLING BACK TO ITS SOURCE PANEL.

DEMO/REMOVE EXISTING PLUMBING FIXTURE INCLUDING ALL ASSOCIATED PIPING AND DRAIN LINES TO BELOW SLAB OR BEHIND EXISTING WALLS TO REMAIN. PATCH ALL REMAINING SURFACES AND PREPARE

TO RECEIVE NEW FINISHES.

DEMO/REMOVE EXISTING ELECTRICAL/DATA ITEM INCLUDING ALL WIRING/CABLING BACK TO ITS SOURCE

PANEL- PATCH REMAINING WALL/FLOOR SURFACES AND PREPARE TO RECEIVE NEW FINISHES.

DEMO/REMOVE EXISTING PHONE BOARD AND/OR SERVER RACK AND ALL ASSOCIATED EQUIPMENT, CABLING, CONDUIT AND ELECTRICAL ITEMS. HOLD RACK IN A PROTECTED LOCATION FOR REUSE IN NEW

LAYOUT.

DEMO/REMOVE EXISTING ELECTRIC PANEL AND HOLD FOR RELOCATION IN NEW LAYOUT. REROUTE ALL WIRING AS POSSIBLE TO NEW LOCATION OR REPORT TO BUILDING MANAGEMENT IF REROUTING IS NOT

POSSIBLE.

EXISTING BUILDING COLUMN TO REMAIN- REDUCE BUILD OUT SIZE TO AS SMALL AS POSSIBLE AND

PROTECT DURING CONSTRUCTION.

CUT HOLE IN FLOOR TO ACCOMMODATE NEW SPRINKLER RISER (APPROX. 6" DIA.)- VERIFY EXACT SIZE AND LOCATION WITH SPRINKLER CLOSET ON FLOOR BELOW AND WITH FIRE PROTECTION CONTRACTOR.

DEMO EXISTING WALL MOUNTED SUPPLEMENTAL HVAC UNIT AND STORE IN PROTECTED AREA FOR

RELOCATION.

DEMO/REMOVE EXISTING PLUMBING FIXTURE. TEMPORARILY CAP OFF PLUMBING LINES AND PREPARE

FOR REROUTE TO NEW SPECIFIED SINK.

1. ALL SHADED AREAS INDICATE "NO WORK" OR "NOT IN CONTRACT" UNLESS OTHERWISE NOTED ON PLAN.

2. REMOVE ALL EXISTING AREAS INDICATED AS DEMOLITION TO PROVIDE LAYOUT SHOWN. CONSTRUCT AND/OR PROVIDE PROTECTION BARRIERS AS NEEDED FOR SAFETY AND TO CONTAIN DUST DUE TO DEMOLITION AND KEEP

BUILDING SECURE AND WEATHER TIGHT DURING THE CONSTRUCTION PERIOD.

3. PATCH AND REPAIR REMAINING SURFACES AS NEEDED DUE TO THE DEMOLITION OR THE REMOVAL OF

CONSTRUCTION.

4. REPAIR HOLES IN EXISTING PARTITIONS TO REMAIN WHERE PARTITION MOUNTED ITEMS ARE TO BE REMOVED. REFER TO FINISH PLAN FOR SCHEDULED FINISH. WHERE PARTITION, EQUIPMENT OR ACCESSORIES, ETC. ARE REMOVED AND NO REPLACEMENT FINISH IS CALLED FOR, PATCH AND REPAIR TO MATCH ADJACENT

FINISH.

5. REMOVE ALL DEMOLISHED MATERIALS FROM THE BUILDING AND THE SITE. ALL DEMOLISHED MATERIALS, EXCEPT AS NOTED, ARE THE PROPERTY OF THE GENERAL CONTRACTOR.

6. REMOVE ANY AND ALL EXISTING ELECTRICAL AND COMMUNICATION EQUIPMENT, SWITCHES, RECEPTACLES, NOT SHOWN ON THE DRAWINGS AND THAT ARE NOT IN USE IN AREAS OF WORK FROM WITHIN PARTITIONS AND ABOVE THE SCHEDULED CEILING. ALL WIRING SHALL BE REMOVED BACK TO ITS SOURCE PANEL.

COORDINATE WITH THE BUILDING CONSTRUCTION MANAGER.

7. SALVAGE AND STORE EXISTING DOORS AND FRAMES AND OTHER ITEMS CALLED OUT TO BE RELOCATED.

MODIFY AS REQUIRED. REPAIR ANY DAMAGE TO ALL EXISTING SURFACES AND ITEMS BEING SALVAGED FOR REUSE. RETURN UNUSED MATERIALS TO BUILDING STORAGE AS DIRECTED BY BUILDING MANAGEMENT.

8. REMOVE ALL FINISHES AND CASEWORK THROUGHOUT SUITE EXCEPT AS NOTED ON PLAN.

9. ALL PLUMBING TO BE REMOVED BELOW SLAB. REPAIR EXISTING SLAB AS REQUIRED TO MEET ALL LOCAL

CODES.

10. REMOVE ALL CEILING TILES (UNLESS DEDUCT ALTERNATE TO KEEP EXISTING TILE IS SELECTED), AND LIGHTING THROUGHOUT SUITE (ONLY IF NEW LED LIGHTS ARE SELECTED IN LIEU OF RETROFITTING EXISTING

LIGHTS - SEE SHEET A3.01) AND PREPARE FOR NEW CEILING TILES AND LED LIGHTING.

DEMOLITION PLAN GENERAL NOTES

DEMOLITION PLAN KEYED NOTES

1 1

2 2

1.03

HOLLOW METAL HEAD DETAIL

SCALE: 3"=1'-0"

5/ 8"

2"

1/2" 1/2"

HOLLOW METAL FRAME - PAINT

DOOR LEAF

DOOR SILENCER

(3) PER LEAF

5/8" 2"

1/ 2"

1/ 2"

3 ANCHORS PER JAMB

DOUBLE JAMB STUDS

SE

E

PA

RT

ITI

ON

TY

PE

S

DOOR LEAF

DOOR SILENCER

(3) PER LEAF

NOTE: STRIKE JAMB SHOWN: HINGE JAMB SIMILAR

1.03

HOLLOW METAL JAMB DETAIL

HOLLOW METAL FRAME - PAINT

SCALE: 3"=1'-0"

2"

VE

RIF

Y"

2"

1/2" SEE PARTITION

TYPES

1/2"

HOLLOW METAL FRAME - PAINT

SEALANT

REMOVABLE STOP

1/4" CLEAR TEMPERED GLASS

HOLLOW METAL FRAME - PAINT

FIRE RETARDANT TREATED WOOD

BLOCKING - FASTENED TO FLOOR

FINISHED FLOOR

1.03

HOLLOW METAL SIDELIGHT DETAIL

SCALE: 3"=1'-0"

2"EQ EQ2" 2" 1'-2"

DOOR LEAF

HOLLOW METAL

FRAME PAINT

SCHEDULED DEVICE 1/4" CLEAR TEMPERED GLASS

REMOVABLE METAL STOP

DOUBLE JAMB STUDS

(3) ANCHORS PER JAMB

SEALANT

HOLLOW METAL

FRAME- PAINT

C.L. OF

SCHEDULED

DEVICE

1.03

HOLLOW METAL SIDELIGHT JAMB DETAIL

SCALE: 3"=1'-0"

10"

2"

'-2

DO

OR

A

ND

F

RA

ME

H

EIG

HT

1/4"

WOOD TRIM AT HEAD ONLY:

DRYWALL CASED OPENING

AT JAMB

HEAVY-DUTY BI-FOLD DOOR

TRACK AND PIVOT HARDWARE

CLOSET SIDE

SCHEDULED BASE

SCHEDULED FLOOR FINISH

DOUBLE JAMB STUDS

METAL CORNER BEADS - TYPICAL

2 x 4 FIRE RETARDANT TREATED

CONTINUOUS BLOCKING

1.03

BI-FOLD DOOR HEAD DETAIL

SCALE: 3"=1'-0"

1.03

BI-FOLD DOOR JAMB DETAIL

SCALE: 3"=1'-0"

SE

E

PA

RT

ITI

ON

TY

PE

S

SEE PARTITION TYPES

2x4 FIRE RETARDANT TREATED

WOOD BLOCKING NESTED IN

METAL STUD TRACK

PRIOR TO CONSTRUCTION COMMENCEMENT, A PROPOSED PLAN FOLLOWING INDUSTRY STANDARDS TO RECYCLE CONSTRUCTION AND DEMOLITION WASTE SHALL BE PREPARED. THE CONSTRUCTION WASTE MANAGEMENT PLAN SHALL QUANTIFY MATERIAL DIVERSION GOALS AND MAXIMIZE THE MATERIALS TO BE RECYCLED AND/OR SALVAGED (AT LEAST 50%) FROM CONSTRUCTION, DEMOLITION, AND PACKAGING DEBRIS. WHERE THE SMALL QUANTITY OF MATERIAL, THE EXTRAORDINARILY COMPLEX NATURE OF THE WASTE DISPOSAL METHOD, OR PROHIBITIVE EXPENSE FOR RECYCLING WOULD REPRESENT A GENUINE HARDSHIP, THE GOVERNMENT, UPON WRITTEN REQUEST OF THE LESSOR AND APPROVAL OF THE LEASE CONTRACTING OFFICER MAY PERMIT

ALTERNATIVE MEANS OF DISPOSAL

CARPET RECLAMATION: RECLAMATION OF EXISTING CARPET TO BE DETERMINED WITH POTENTIAL VENDOR.

WHERE CARPET IS REPLACES, SUBMIT CERTIFICATION DOCUMENTATION FROM THE RECLAMATION FACILITY TO THE

LCO (LEASE CONTRACTING OFFICER).

CONSTRUCTION WASTE MANAGEMENT PLAN

NOTE: REFER TO SHEETS A1.02, A1.03, A1.04, AND A1.05, VA

SPECIFIC GENERAL NOTES, WHICH SUPPLEMENT THE NOTES ON

THIS PAGE. VA SPECIFIC NOTES WITH MORE STRINGENT

REQUIREMENTS SUPERCEDE ALL NOTES FOUND IN DRAWINGS.

FE

REVISIONS

ALIGNED

STUDIO, LLC

ARCHITECTURE + DESIGN

MISSOURI CERTIFICATE OF AUTHORITY

No. 2016030702

DRAWN BY:

REVIEWED BY:

13100 MANCHESTER

JOB NO.

DATE:

CONTACT:

314.317.0060

SUITE 225

ST. LOUIS, MO 63131

www.aligned-studio.com

OF

CO

NS

TR

UC

TIO

N

DO

CU

ME

NT

S

FO

R:

DE

PA

RT

ME

NT

O

F

VE

TE

RA

NS

' A

FF

AIR

S

RE

AD

JU

ST

ME

NT

C

OU

NS

EL

IN

G

SE

RV

ICE

S

NO

RT

H

OU

TE

R

TO

W N

AN

D

CO

UN

TR

Y, MI

SSO

UR

I 6

MICKI WEHMEIER

micki@aligned-studio.com

RANDY WINZEN

randy@aligned-studio.com

1720.1

11.01.17

A2.01

FLOOR PLAN

& PARTITION TYPES

RCW

RCW

PARTIAL SECOND FLOOR PLAN

SCALE: 1/8"=1'-0"

FLOOR PLAN GENERAL NOTES

1. ALL SHADED AREAS INDICATE "NO WORK" OR "NOT IN CONTRACT" UNLESS OTHERWISE NOTED ON PLAN.

2. ALL PARTITIONS SHALL BE "P1" UNLESS OTHERWISE NOTED ON PLAN. SEE SEISMIC DETAILS 1, 5 & 9/A3.01

AND PARTITION TYPES, SHEET A2.01.

3. ALL ANGLES SHALL BE 90 DEGREES UNLESS OTHERWISE NOTED ON PLAN.

4. ALL OPENINGS TO BE MINIMUM 3'-0" WIDE CLEAR UNLESS OTHERWISE DIMENSIONED ON PLAN.

5. PROVIDE AND INSTALL FIRE RETARDANT WOOD BLOCKING IN WALL FOR ALL BUILT-IN MILLWORK, TYPICAL.

6. ALL GLAZING SHALL BE TEMPERED. SEE PLAN AND\/OR ELEVATIONS FOR SPECIFIC GLASS WIDTH DIMENSIONS.

ORDER ALL GLASS WITHOUT MANUFACTURERS STAMP AND FREE OF BLEMISHES AND TONG MARKS.

7. GENERAL CONTRACTOR TO COORDINATE ALL HORN STROBE AND/OR FIRE ALARM PULL STATION LOCATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. GC MUST USE BUILDING STANDARD FIRE ALARM DEVICES WHEN FURNISHING ADDITIONAL FIRE ALARM DEVICES AND MUST USE A LANDLORD APPROVED SIMPLEX CONTRACTOR FOR MAKING

CONNECTIONS TO THE FIRE ALARM SYSTEM.

8. GC TO FURNISH AND INSTALL 5 GAL HOT WATER HEATER ABOVE CEILING WITH DRAIN LINE AND OVERFLOW PAN- SEISMICALLY BRACE TO STRUCTURE ABOVE PER MFGR. REQUIREMENTS. (BREAK ROOM 232). SEE M.E.P.

DRAWINGS.

9. PROVIDE AND INSTALL NEW VERTICAL BLINDS AT ALL EXTERIOR WINDOWS. WAND OPERATION ONLY. NO

CORDS WILL BE PERMITTED.

10. PROVIDE 1" RADIUS AT ALL COUNTERTOPS WITH OPEN ENDED CORNERS.

1 ALIGN NEW PARTITION WITH EXISTING CONSTRUCTION OR PARTITIONS ACROSS OPENINGS IN SAME

PLANE WITH NO VISIBLE JOINTS

REPLACE ANY FINISHES DISTURBED BY CONSTRUCTION WITH NEW TO MATCH EXISTING. VERIFY EXTENT

OF WORK IN FIELD.

CENTER NEW PARTITION ON EXISTING WINDOW MULLION- VERIFY EXACT LOCATION IN FIELD.

EXISTING BUILDING COLUMN. REDUCE TO SMALLEST POSSIBLE DIMENSION AN PATCH AS REQUIRED-

PROTECT DURING CONSTRUCTION.

NEW ELECTRIC PANELS AND TRANSFORMER- TO BE SIZED, LOCATED AND COORDINATED BY ELECTRICAL

DESIGN BUILD CONTRACTOR. (NETWORK 231). SEE ENLARGED PLAN 14/3.02.

PROVIDE COLD WATER LINE WITH SHUT OFF VALVE FOR TENANT'S REFRIGERATOR ICEMAKER, AND

COFFEE MAKER (BREAK ROOM 232)- VERIFY EXACT MFGR. REQUIREMENTS.

NEW PLASTIC LAMINATE RECEPTION DESK BY OTHERS.

PLASTIC LAMINATE BASE AND WALL CABINETS WITH PLASTIC LAMINATE COUNTERTOP- SEE INTERIOR

ELEVATIONS ON A4.01.

(5) 15" DEEP MELAMINE ADJUSTABLE SHELVES ON HEAVY DUTY STANDARDS AND BRACKETS- PROVIDE

TREATED WOOD BLOCKING AS REQUIRED. SEE DETAIL 16/5.01

PROVIDE GALV. CORNER BEADS AT NEWLY EXPOSED CORNERS AFTER DEMOLITION.

6'-0" X 4'-0" X 3/4" FIRE RETARDANT PLYWOOD PHONE BOARD. MOUNT AT 72" A.F.F. AND PAINT TO MATCH ADJACENT WALL- VERIFY EXACT LOCATION WITH TENANT AND M.E.P. DRAWINGS (NETWORK

231). SEE ENLARGED PLAN 14/3.02

18" DEEP PAINT GRADE PLYWOOD SHELF MOUNTED AT 68" A.F.F. AND 1 1/2" DIA. METAL CLOTHES

ROD WITH SUPPORT BRACKET AT MID SPAN. SEE DETAIL 19/4.01

25" DEEP PLASTIC LAMINATE COUNTERTOP WITH 2" RADIUS AT OPEN CORNER, MOUNTED AT 42" A.F.F. PROVIDE PERIMETER SUPPORT AT WALLS AND BRACING AT MIDSPAN- SEE DETAIL 15/4.01.

INCREASE DEPTH OF OFFICE AS MUCH AS POSSIBLE BASED ON REDUCTION OF EXISTING COLUMN BUMP

OUT AND MAINTAINING 44" CLEAR AISLE SPACE IN CORRIDOR.

NEW STAINLESS STEEL SURFACE MOUNTED SINK AND ADA COMPLIANT FAUCET WITH GOOSENECK

HANDLES. PROVIDE ALL REQUIRED PLUMBING LINES AND DRAINS, ETC. AND 1/2 HP GARBAGE

DISPOSAL (BADGER #5 OR EQUAL) IN BREAK ROOM 232.

PROVIDE TREATED WOOD BLOCKING IN WALL FOR THE MOUNTING OF ADA COMPLIANT GRAB BARS.

NEW 18" X 7'-0" X 1/4" TEMPERED GLASS SIDELIGHT IN PAINTED HOLLOW METAL FRAME (TYP.)- SEE

INTERIOR ELEVATION ON SHEET A4.01.

4" DIA. FLOOR DRAIN- SEE PLUMBING DESIGN BUILD DRAWINGS FOR EXACT SPECIFICATIONS AND

LOCATIONS.

PROVIDE NEW MINIMUM DRYWALL ENCLOSURE AS REQUIRED AROUND NEW SPRINKLER PIPE- VERIFY EXACT SIZE AND LOCATION WITH FIRE PROTECTION CONTRACTOR AND SPRINKLER CLOSET BELOW.

PROVIDE TRANSLUCENT SECURITY FILM ON OFFICE SIDE OF COMMON CORRIDOR GLAZING.

ALL CORRIDOR WALLS SHALL TERMINATE AT DECK ABOVE. UPGRADE EXISTING CORRIDOR WALLS AS

REQUIRED TO MEET ONE HOUR RATING OR CONSTRUCT NEW CORRIDOR WALLS ACCORDINGLY.

PROVIDE HOT WATER PUMP AT SINKS TO OPERATE DURING BUSINESS HOURS ONLY IN ORDER TO

BRING WATER TEMPERATURE TO VA STANDARDS.

RELOCATED WALL MOUNTED SUPPLEMENTAL HVAC UNIT- VERIFY UNIT CAN HOLD TEMPERTURE

BETWEEN 70 AND 75 DEGREES. VERIFY EXACT LOCATION IN FIELD. SEE ENLARGED PLAN 14/3.02.

ALL DEMISING WALLS SHALL TERMINATE AT DECK ABOVE. VERIFY IF EXISTING DEMISING WALL

COMPLIES AND UPGRADE AS REQUIRED TO MEET ONE HOUR RATING.

PROVIDE NEW FURRED WALL IN FRONT OF EXISTING DEMISING WALL TO PROVIDE SOUND BARRIER

FROM ADJACENT TENANT. SEE PARTITION TYPES ON SHEET A2.01.

FLOOR PLAN KEYED NOTES X

1. ALL DOOR OPERATING DEVICES SHALL BE CAPABLE OF OPERATION WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, TWISTING OF THE WRIST OR TIGHT PINCHING. DOOR KNOBS ARE PROHIBITED.

2. ALL MEANS OF EGRESS DOORS SHALL BE READILY OPENABLE FROM THE SIDE FROM WHICH EGRESS IS TO BE

MADE WITHOUT THE USE OF A KEY, SPECIAL TOOL, KNOWLEDGE OR EFFORT.

3. MEANS OF EGRESS DOORS EQUIPPED WITH MAGNETIC LOCKS, CARD READERS, PUSH BUTTON COMBINATION LOCKS, OR OTHER SPECIAL LOCKS SHALL BE ABLE TO UNLOCK IN ACCORDANCE WITH ALL 7 CONDITIONS LISTED

IN THIS CODE SECTION.

4. PRIMARY ENTRANCE DOOR HARDWARE SHALL BE MADE ACCESSIBLE WHEN ANY PORTION OF THE ACCESSIBLE

ROUTE IS ALTERED.

5. SEE SHEET A1.01, SECTION III, 'DOORS, FRAMES AND HARDWARE'. SEE DOOR TYPES AND HARDWARE GROUPS THIS SHEET. CONTRACTOR TO COORDINATE DOOR UNDERCUTS AS REQUIRED WITH MECHANICAL

CONTRACTOR.

6. COORDINATE KEYING WITH TENANT AND BUILDING MANAGEMENT. PROVIDE BUILDING STANDARD FINISH.

UPGRADE EXISTING HARDWARE AS REQUIRED TO ADA COMPLIANT LEVER STYLE HARDWARE.

7. THE GENERAL CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS PIECES, SILENCERS, SEALS, DOOR STOPS, ETC.

AS REQUIRED FOR A COMPLETE INSTALLATION OF ALL INTERIOR DOORS. ALL DOORSTOPS TO BE FLOOR

MOUNTED AT A 90-DEGREE ANGLE TO THE DOOR OPENING, UNLESS NOTED OTHERWISE.

8. AS A PART OF THIS SCOPE, THE EXTERIOR DOORS TO THE BUILDING SHALL BE UPGRADED AS PER THE

FOLLOWING SECURITY SYSTEM COMPONENTS:

A. PROVIDE AND INSTALL 1200 LB MAGNETIC HOLD OPEN DEVICES

B. PROVIDE AND INSTALL SLIM PUSH TO RELEASE EXIT BUTTONS AT INTERIOR DOORS.

C. PROVIDE AND INSTALL PIR DETECTORS AT CEILING

D. PROVIDE AND INSTALL WEATHERPROOF KEYPADS

E. PROVIDE AND INSTALL REQUIRED POWER SUPPLY

F. PROVIDE AND INSTALL FIRE ALARM RELAY AND WIRING AS PER TECH ELECTRONICS

G. PROVIDE AND INSTALL TIMER PACKAGE FOR CONTROLLED RELEASE OF MAGNETIC HOLD OPEN

DEVICES.

H. PROVIDE AND INSTALL 120 V DEDICATED CIRCUIT TO POWER SUPPLY PANEL

I. PROVIDE AND INSTALL LOW VOLTAGE WIRING TO ALL DEVICES VIA SURFACE MOUNTED WIRE MOLD.

DOOR NOTES XDOOR TYPES XHARDWARE TYPES

EXISTING DOOR AND FRAME TO REMAIN. PATCH AND/OR REPAIR TO NEWER CONDITION AND TO

MATCH BUILDING STANDARD FINISH OR AS SPECIFIED.

NEW 3'-0" X 7'-0" X 1 3/4" SOLID CORE, WOOD VENEER DOOR IN A PAINTED HOLLOW METAL FRAME. DOOR STAINED TO MATCH BUILDING STANDARD. SEE DOOR NOTES ON SHEET A1.01. SEE

FRAME DETAILS 1/1.03 & 5/1.03.

NEW PAIR OF 3'-0" X 7'-0" X 1 3/4" SOLID CORE, WOOD VENEER DOORS IN A PAINTED HOLLOW METAL FRAME. DOOR STAINED TO MATCH BUILDING STANDARD. SEE DOOR NOTES ON SHEET A1.01.

SEE FRAME DETAILS 1/1.03 & 5/1.03.

NEW 3'-0" X 7'-0" X 1 3/4" SOLID CORE, WOOD VENEER ENTRY DOOR WITH A 1'-8" X 7'-0" X 1/4" TEMPERED GLASS SIDELIGHT, BOTH IN A PAINTED HOLLOW METAL FRAME. DOOR STAINED TO MATCH BUILDING STANDARD. SEE DOOR NOTES ON SHEET A1.01. SEE FRAME DETAILS 1/1.03 & 5/1.03.

NEW PAIR OF 2'-0" X 7'-0" X 1 3/4" SOLID CORE, WOOD VENEER BI-FOLD DOORS IN A DRYWALL

CASED OPENING. DOORS STAINED TO MATCH BUILDING STANDARD. SEE DOOR NOTES ON SHEET

A1.01. SEE DETAILS 14/1.03 & 15/1.03.

NEW 3'-6" X 7'-0" X 1 3/4" SOLID CORE, WOOD VENEER DOOR IN A PAINTED HOLLOW METAL FRAME. DOOR STAINED TO MATCH BUILDING STANDARD. SEE DOOR NOTES ON SHEET A1.01. SEE

FRAME DETAILS 1/1.03 & 5/1.03.

EXISTING HARDWARE TO REMAIN. MAKE SURE IT'S IN GOOD WORKING ORDER AND UPGRADE TO BE

ADA ACCESSIBLE AS REQUIRED.

NEW LEVER STYLE OFFICE LOCKSET WITH 1 1/2 PAIR BUILDING STANDARD BUTT HINGES, AND DOME

TYPE FLOOR STOP.

NEW LEVER STYLE PASSAGE SET WITH 1 1/2 PAIR BUILDING STANDARD BUTT HINGES AND DOME STYLE

FLOOR STOP.

NEW LEVER STYLE STOREROOM LOCKSET WITH 1 1/2 PAIR BUILDING STANDARD BUTT HINGES, DOOR

CLOSER AND DOME STYLE FLOOR STOP.

NEW LEVER STYLE PRIVACY LOCKSET, 1 1/2 PAIR BUTT HINGES AND DOME STYLE FLOOR STOP.

NEW LEVER STYLE DUMMY HANDLES ON CORRIDOR SIDE (BLANK ON CLOSET SIDE), 3 PAIR BUTT HINGES, DOME STYLE FLOOR STOPS AND HEAVY DUTY ROLLER CATCHES ON TOP OF EACH LEAF.

NEW LEVER STYLE KEYED ENTRY LOCKSET, 1 1/2 PAIR BUTT HINGES, DOOR CLOSER AND DOME TYPE

FLOOR STOP- DOOR TO BE OPERABLE FROM EGRESS SIDE AT ALL TIMES.

BI-FOLD DOOR MANUFACTURER HARDWARE, TRACKS AND ROLLERS- ALL HARDWARE SHALL BE ADA

COMPLAINT.

NOTE: COORDINATE KEYING WITH TENANT AND BUILDING MANAGEMENT. PROVIDE BUILDING

STANDARD FINISH.

NOTE: UPGRADE EXISTING HARDWARE AS REQUIRED TO ADA COMPLIANT LEVER STYLE HARDWARE.

A

B

NOTES:

SEE SHEET A1.01, SECTION III, 'DOORS, FRAMES AND HARDWARE'. CONTRACTOR TO COORDINATE DOOR UNDERCUTS AS

REQUIRED WITH MECHANICAL CONTRACTOR.

C

4D

E

6'-8" 13'-3"+/-

7'- 4"

2'- 1"

8'- 0"

1'- 0"

7'-

1/ 2"

4'-2"2'-10"+/-

1'-

1/ 4"

5'-0"

1'-0

1'-6

1'-0

1'-6

1'-0

1'-6

1'-0

1'-6

1'-0

1'-6

1'-0

1'-6

3'-4"

8'-1 3/

4"

1'-6

1'-0

1'-6

1'-0

1'-6" 1'-0"

1'-6" 1'-0"

1'-6"

1'-0"

1'-6

1'-0

1'-6

1'-0

1'-6"

1'-0"

1'-6"

1'-0"

1'-0"

1'-6"

1'-0" 1'-6"

1'-6"

1'-0"

1'-6

1'-0

1'-6

1'-0

2'- 6"

1'-8"

(1'-6" MIN.)

4.01

5'-0"

15'-8"

15'-8"

8'-0 1/4"+/-

9'-8 1/

4"

19' -8 1/4

5'-0

9'-8 1/

4"

9'-8 1/

4"

5'-0

3'-8"(MIN.)

11'-11"+/- 5'-0"

15'-0"+/-

EQ

EQ

5'-0"

13'-5"+/-

EQ

EQ

5'-0

5'-0

1'-4

4'-4 1/

2"+

9'-0 1/

4"+

2'-11"

2'-3"

1'-10"

1'-2 1/2"+/-

7'-8"

10'-8 5/8"

5'-0" 1'-8"

2'-3

5/8"

4 4

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

SES DIRECTOR

OFFICE

CONFERENCE

WORK RM.

TRAINING/

MULTIPURPOSE

ADA

MEN

ADA

WOMEN

OFFICE

OFFICE

OFFICE

NETWORK

OFFICE

BREAK

ROOM

STOR.

WAITING

COATS

CORRIDOR

CORR.

CORR.

CORR.

CORR.

CORR.

RECEPTION

BUILDING

CORRIDOR

STOR.

CORR.

CORR.

F

A

A

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

B

F

B

B

B

B

B

F

F

C

D

2.01 TYP.

2.01 TYP.

4.0

4.0

4.0

E

17 17

F

SCHEDULED BASE

SCHEDULED FLOOR FINISH

3 5/8" METAL STUDS, 25 GA. AT 16" O.C.

5/8" GYPSUM BOARD EACH SIDE

4 7/8"

USG 200-B METAL GYPSUM BOARD TRIM

SCHEDULED CEILING

8'- 6"

(V

ER

IFY

IN

F

IEL

D)

3 1/2" SOUND BATT INSULATION

SOUND BATT INSULATION TO 4'-0"

EACH SIDE OF PARTITION

WALL BASE

SCHEDULED FLOOR FINISH

3 5/8" METAL STUDS, (25 GA.) AT 16" O.C.

5/8" GYPSUM BOARD EACH SIDE

4 7/8"

EXISTING DECK- FIELD VERIFY

8'- 6"

6"

NEW DRYWALL CEILING

PARTITION TYPE

SCALE: 1 1/2"=1'-0"

(SE

E

RE

FL

EC

TE

D

CE

ILI

NG

P

LA

N)

3 1/2" SOUND ATTENUATION FRICTION FIT BATTS

P1

NEW OR EXISTING

ACOUSTIC CEILING

PARTITION TYPE

SCALE: 1 1/2"=1'-0"P2

3 1/2" SOUND ATTENUATION

BATTS TO EXTEND 4'-0" ON

EACH SIDE OF PARTITION

SCHEDULED BASE

SCHEDULED FLOOR FINISH

3 5/8" METAL STUDS, 25 GA. AT 16" O.C.

5/8" DRYWALL EACH SIDE

1'-0"

EXISTING DECK - FIELD VERIFY

8'- 6"

(F

IEL

D

VE

RIF

Y)

3 1/2" SOUND ATTENUATION FRICTION FIT BATTS

2 1/2" METAL STUDS AT 48"

O.C. VERTICALLY EACH STUD

DRYWALL CEILING

6"

PARTITION TYPE

SCALE: 1 1/2"=1'-0"P3 PLUMBING CHASE WALL

3 1/2" SOUND ATTENUATION

BATTS TO EXTEND 4'-0" ON

EACH SIDE OF PARTITION

NOTE: PARTITIONS TO TERMINATE AT 9'-0"

A.F.F. AND KICK BACK TO STRUCTURE ABOVE

PER SEISMIC BRACING DETAIL 5/A3.02

RESTROOM SIDE

PARTITION TYPE

SCALE: 1 1/2"=1'-0"P4

SCHEDULED BASE

SCHEDULED FLOOR FINISH

2 1/2" METAL STUDS, 25

GA. AT 16" O.C.

5/8" TYPE DRYWALL

3 1/8"

8'- 6"

6"

SCHEDULED CEILING

2 1/2" R-13 INSULATION WITH

VAPOR BARRIER

EXISTING PARTITION OR COLUMN

1/2" AIR SPACE

NOTE: PARTITIONS TO TERMINATE AT 9'-0"

A.F.F. AND KICK BACK TO STRUCTURE ABOVE

PER SEISMIC BRACING DETAIL 5/A3.02

NOTE: PARTITIONS TO TERMINATE AT 9'-0"

A.F.F. AND KICK BACK TO STRUCTURE ABOVE

PER SEISMIC BRACING DETAIL 5/A3.02

24" MAX.

(JOG TO CLOSEST MULLION)

1/ 2"

N.T .S

2.01

DETAIL AT PARTITION AT MULLION

SCALE: 3"=1'-0"

EXISTING CURTAIN WALL SYSTEM.

DO NOT FASTEN INTO OR THRU

EXISTING MULLION

SEALANT- COLOR TO MATCH MULLION

DOUBLE SIDED FOAM TAPE

U.S.G. 200A FILL BEAD PAINT

OUTSIDE EDGE TO MATCH MULLION

PERIMETER BASE HEATER (WHERE OCCURS).

FILL VOID WITH FIBERGLASS SOUND BATTING.

SCRIBE GYPSUM BOARD TO SILL

AND HEATER BELOW.

HOLD TIGHT TO EXTERIOR WALL AS

POSSIBLE (12" TYP.) ALLOW FOR

BASEBOARD HEATING AND CIRCULATION

C/L OF MULLION = C/L OF PARTITION

UNLESS OTHERWISE NOTED ON FLOOR PLAN

SILL BELOW

1'-0" 1'-6" 1'-0"1'-6"

TYP.

1'-4" 4'-3"

1'-1

ENVIRONMENTALLY PREFERABLE PRODUCT REQUIREMENTS

A. THE GC MUST PROVIDE ENVIRONMENTALLY PREFERABLE PRODUCTS AS DETAILED THROUGHOUT THE SUITE. (I.E.: PLUMBING FIXTURES,WATER

CONSERVATION)

B. WHEN THE DRAWINGS DO NOT CONTAIN SPECIFIC REQUIREMENTS FOR ENVIRONMENTALLY PREFERABLE PRODUCTS, THE GC MUST PROVIDE PRODUCTS MEETING ONE OF THE BELOW ENVIRONMENTALLY PREFERABLE CRITERIA WHEN SUCH PRODUCTS ARE AVAILABLE. THE GC CAN CONSULT THE GREEN PROCUREMENT COMPILATION AT WWW.SFTOOL.GOV/GRENPROCUREMMENT TO DETERMINE WHETHER ANY OF THESE CRITERIA ARE APPLICABLE FOR A

PRODUCT CATEGORY.

1. BIO-PREFERRED PRODUCTS

2. ENERGY STAR PRODUCTS

3. EPA COMPREHENSIVE PROCUREMENT GUIDELINE DESIGNATED (RECYCLED CONTENT) PRODUCTS

4. EPA SAFER CHOICE LISTED PRODUCTS

5. FEMP-DESIGNATED ENERGY EFFICIENT PRODUCTS

6. SNAP (SIGNIFICANT NEW ALTERNATIVE POLICY) SUBSTANCES

7. WATER SENSE OR OTHER WATER EFFICIENT PRODUCTS.

C. THE GC, IF UNABLE TO COMPLY WITH THE ENVIRONMENTALLY PREFERABLE PRODUCT REQUIREMENTS ABOVE, MUST SUBMIT A WAIVER REQUEST FOR EACH MATERIAL WITHIN THE TI PRICING SUBMITTAL. THE WAIVER REQUEST SHALL BE BASED ON THE FOLLOWING EXCEPTIONS:

1. PRODUCT CANNOT BE ACQUIRED COMPETITIVELY WITHIN A REASONABLE PERFORMANCE SCHEDULE.

2. PRODUCT CANNOT BE ACQUIRED THAT MEETS REASONABLE PERFORMANCE REQUIREMENTS.

3. PRODUCT CANNOT BE ACQUIRED AT A REASONABLE PRICE.

4. AN EXCEPTION IS PROVIDED BY STATUTE.

THE PRICE SHALL BE DEEMED UNREASONABLE WHEN THE TOTAL LIFE CYCLE COSTS ARE SIGNIFICANTLY HIGHER FOR THE SUSTAINABLE PRODUCT VERSUS THE NON- SUSTAINABLE PRODUCT. LIFE CYCLE COSTS ARE DETERMINED BY COMBINING THE INITIAL COSTS OF A PRODUCT WITH ANY ADDITIONAL COSTS

OR REVENUES GENERATED FROM THAT PRODUCT DURING ITS ENTIRE LIFE.

NOTE: REFER TO SHEETS A1.02, A1.03, A1.04, AND A1.05, VA

SPECIFIC GENERAL NOTES, WHICH SUPPLEMENT THE NOTES ON

THIS PAGE. VA SPECIFIC NOTES WITH MORE STRINGENT

REQUIREMENTS SUPERCEDE ALL NOTES FOUND IN DRAWINGS.

P4

3 5/8"

NOTE: ANY NEW OR EXISTING PARTITION THAT HAS A CONTINUOUS UNINTERRUPTED

RUN OF OVER 12'-0" IN LENGTH IS REQUIRED TO HAVE THE TOP OF THE PARTITION

SEISMICALLY BRACED TO THE STRUCTURE ABOVE WITH METAL STUD KICKERS PER THE

DETAILS PROVIDED ON THE DRAWINGS. ANY WALLS WITH INTERSECTING

PERPENDICULAR PARTITIONS AT INTERVALS OF LESS THAT 12'-0" CAN ELIMINATE THE

KICKERS AND ARE NOT REQUIRED TO BE SEISMICALLY BRACED.

REVISIONS

ALIGNED

STUDIO, LLC

ARCHITECTURE + DESIGN

MISSOURI CERTIFICATE OF AUTHORITY

No. 2016030702

DRAWN BY:

REVIEWED BY:

13100 MANCHESTER

JOB NO.

DATE:

CONTACT:

314.317.0060

SUITE 225

ST. LOUIS, MO 63131

www.aligned-studio.com

OF

CO

NS

TR

UC

TIO

N

DO

CU

ME

NT

S

FO

R:

DE

PA

RT

ME

NT

O

F

VE

TE

RA

NS

' A

FF

AIR

S

RE

AD

JU

ST

ME

NT

C

OU

NS

EL

IN

G

SE

RV

ICE

S

NO

RT

H

OU

TE

R

TO

W N

AN

D

CO

UN

TR

Y, MI

SSO

UR

I 6

MICKI WEHMEIER

micki@aligned-studio.com

RANDY WINZEN

randy@aligned-studio.com

1720.1

11.01.17

A2.02

FINISH PLAN &

FINISH SPECIFICATIONS

RCW

RCW

PARTIAL SECOND FLOOR FINISH PLAN

SCALE: 1/8"=1'-0"

BASE:

DOORS:

FRAMES:

WALLS:

VB-1

BUILDING STANDARD

P-4 P-1

C-1

CARPET

STYLE:

MFG:

INSTALL:

COLOR:

P-1 MFG:

PLASTIC LAMINATE

CONTACT:

P-2 MFG:

COLOR/NO.:

FINISH:

COLOR/NO.:

PATCRAFT

10291 EXPERIENCE

00425 SOLUTION

ASHLAR

TODD HEILMAN, 314.640.6521

VCT-1

VINYL COMPOSITION TILE

STYLE:

SIZE:

MFG:

CONTACT:

COLOR:

ARMSTRONG

STANDARD EXCELON

PEAT 59240

12" X 12"

NANCY WASER, 636-448-9409

PL-1

WK

TOPS

STYLE:

FINISH:

MFG:

CONTACT:

COLOR NO.:

FORMICA

BLACKENED STEEL

8918-58

MATTE

RICHELE SMITH 816.337.6235

PL-2

WK

FACE

STYLE:

FINISH:

MFG:

CONTACT:

COLOR NO.:

FORMICA

GRAPHITE

837-58

MATTE

RICHELE SMITH, 816.377.6235

P-3 MFG:

COLOR/NO.:

FINISH:

FINISH:

FINISH SPECIFICATIONS

FINISH SYSTEMS

PPG

PPG-1007-4 HOT STONE

EGGSHELL

SHERWIN WILLIAMS

SW2820 DOWNING EARTH

EGGSHELL

SHERWIN WILLIAMS

SW6250 GRANITE PEAK

EGGSHELL

BASE:

DOORS:

FRAMES:

WALLS:

LV-1

LUXURY VINYL PLANK

STYLE:

SIZE:

MFG:

CONTACT:

COLOR:

PATCRAFT

TIMBER GROVE II 1420V

00572 HEMLOCK

5.96" X 48"

TODD HEILMAN, 314.640.6521

VB-1

BUILDING STANDARD

P-4 P-2

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

SES DIRECTOR

OFFICE

CONFERENCE

WORK RM.

TOILET

OFFICE

OFFICE

OFFICE

NETWORK

OFFICE

BREAK

ROOM

STOR.

WAITING

COATS

CORRIDOR

CORR.

CORR.

CORR.

CORR.

CORR.

RECEPTION

BUILDING

CORRIDOR

STOR.

CORR.

CORR.

OFFICE

OFFICE

TRAINING/

MULTIPURPOSE

EXISTING CONCRETE SLAB

(SHOWN SHADED)

VINYL FLOORING

CARPET

VINYL TRANSITION CAP TO MATCH TILE

2.02

FLOORING TRANSITION

FULL SCALE

FINISH PLAN GENERAL NOTES FINISH PLAN KEYED NOTES

11. PROVIDE AND INSTALL NEW CARPET, VINYL BASE AND PAINT THROUGHOUT SUITE UNLESS OTHERWISE NOTED.

2. ALL HARDWARE TO MATCH BUILDING STANDARD FINISH, UNLESS OTHERWISE NOTED.

3. ALL MILLWORK TO BE SHOP FINISHED. ALL PAINTED MILLWORK TO BE SHOP SPRAYED PAINTED LOW GLOSS LACQUER FINISH.

4. FLOOR TRANSITIONS SHALL OCCUR AT THE CENTERLINE OF DOOR, UNLESS OTHERWISE NOTED.

5. PROVIDE AND CONTINUE SCHEDULED FLOORING FROM PARTITION TO PARTITION AND UNDER MILLWORK UNLESS OTHERWISE NOTED.

6. PROVIDE HIGH GLOSS WAX FINISH ON ALL SCHEDULED VCT FLOORING.

7. DO NOT PROVIDE SCHEDULED RUBBER/VINYL BASE ON MILLWORK PLASTIC LAMINATE TOE-KICK TYPICAL. REFER TO MILLWORK

SECTIONS/DETAILS.

8. SEAM SEALER REQUIRED AT ALL BROADLOOM CARPET SEAMS AND EXPOSED (UNBOUND) EDGES IN ACCORDANCE WITH THE CRI INSTALLATION

INSTRUCTIONS.

9. PROVIDE 4" HIGH COVED BASE AT ALL CARPETED AREAS AND HARDSURFACE FLOORING AREAS UNLESS OTHERWISE NOTED ON PLANS.

10. FINISH SYSTEMS DESCRIBE THE FINISH SPECIFICATION FOR THE VERTICAL SURFACE AT ALL ITEMS PLACED ON A PARTITION. IF DISCREPANCY OCCURS, CONTACT THE ARCHITECT FOR CLARIFICATION PRIOR TO STARTING WORK WITHIN THE SUBJECT AREA.

EXISTING FINISHES TO REMAIN. MATCH FINISHES (BASE, PAINT, FLOORING) AT REWORKED ENTRY TO RECEPTION

AND ALONG DEMISE LOCATION WHERE NEW DRYWALL HAS BEEN INSTALLED.

PROVIDE AND INSTALL ACROVYN CORNER GUARD. SSM SERIES, #SSM-20, PARTIAL HEIGHT COLOR TO MATCH ADJACENT PAINT. GC TO PROVIDE SAMPLES. CORNER GUARD SHALL EXTEND FROM TOP OF BASE TO 48" AFF.

VERIFY IF CORNER GUARD SPECIFIED IN KEYED NOTE #2 AND BE BENT TO ACCOMMODATE 135 DEGREE

ANGLE.

PROVIDE AND INSTALL ACROVYN BG30N CHAIR RAIL AT 30" AFF O.C. (COORDINATE EXACT HEIGHT WITH TENANT'S FURNITURE VENDOR) AT ALL DRYWALL PARTITIONS OF CONFERENCE ROOM CAN MULTI-PURPOSE ROOM.

COLOR TO MATCH ADJACENT PAINT. GC TO PROVIDE SAMPLES.

PROVIDE AND INSTALL CARPET INSET OF C-1 BENEATH RECEPTION DESK. COORDINATE EXACT LOCATION AND SIZE OF DESK WITH TENANT'S FURNITURE VENDOR. REAR EDGE OF INSERT SHALL ALIGN WITH FRONT PARTITION

OF COAT CLOSET.

X

VB-1

VINYL BASE

STYLE:

SIZE:

MFG:

CONTACT:

COLOR:

JOHNSONITE

COVED STANDARD BASE

29 MOONROCK WG

4" MICHELLE LEBBING, 314.739.2273 x1013

PAINT

C 1

C 1

C 1

C 1

C 1

C 1

C 1

C 1

C 1

C 1

C 1

C 1

C 1

C 1

C 1

C 1

C 1

C 1

C 1

VP 1

VP 1

X

VP 1

C 1

C 1

C 1

P-4 MFG:

COLOR/NO.:

FINISH:

PPG

PPG-1007-4 HOT STONE

ENAMEL

BASE:

DOORS:

FRAMES:

WALLS:

VB-1

BUILDING STANDARD

P-4 P-3

VP 1

TOILET

VP 1

VCT 1

VP 1

VP 1

VP 1

VP 1

VP 1

VP 1

VP 1

VP 1

VP 1

VP 1

2.02

2.0214

2.02

2.02

2.02

2.02

2.02

2.02

2.02

2.02

2.02

2.02

2.02

2.02

2.02

2.02

2.02

2.02

2.02

INDOOR ENVIRONMENTAL QUALITY NOTES

ALL ADHESIVES AND SEALANTS APPLIED IN THE PREMISES SHALL COMPLY WITH THE REQUIREMENTS OF LEED CREDIT

IEQ4.1

INTERIOR PAINTS AND COATINGS APPLIED IN THE PREMISES MUST MEET THE LIMITATIONS AND RESTRICTIONS CONCERNING

CHEMICAL COMPONENTS ST BY LEED CREDIT IEQ4.2. VA SPECIFICS AS FOLLOWS:

1. TOP COAT PAINTS: GREEN SEAL STANDARD GS-11, PAINTS FIRST EDITION MAY 20,1993

2. ALL OTHER ARCHITECTURAL COATINGS, PRIMERS, AND UNDERCOATS: SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT

(SCAQMD) RULE 1113,

ARCHITECTURAL COATINGS EFFECTIVE JANUARY 1, 2004.

3. ARCHITECTURAL PAINTS, COATINGS, AND PRIMERS APPLIED TO INTERIOR WALLS AND CEILINGS:

A. FLATS: 50 GRAMS PER LITER (G/L)

B. NON-FLATS: 150 G/L

4. ANTI CORROSIVE AND ANTI-RUST PAINTS APPLIED TO INTERIOR FERROUS METAL SUBSTRATES: 250 G/L.

5. CLEAR WOOD FINISHES

A. VARNISH: 350 G/L

B. LACQUER: 550 G/L

6. FLOOR COATINGS: 100G/L

7. SEALERS:

A. WATERPROOFING SEALERS: 250 G/L

B. SANDING SEALERS: 275 G/L

C. ALL OTHER SEALERS: 200 G/L

8. SHELLACS:

A. CLEAR: 730 G/L

B. PIGMENTED: 550 G/L

9. STAINS: 250G/L

ALL FLOORING MATERIAL MUST MEET THE STANDARDS CONTAINED IN LEED CREDIT IEQ4.3, INCLUDING CARPET, CARPET ADHESIVES, AND HARD SURFACE FLOORING. CARPET MUST HAVE CERTIFICATION AS A GOLD LEVEL MIN. FOR THE ANSI/NSF 140 2007E SUSTAINABLE CARPET ASSESSMENT STANDARD. CARPET MANUFACTURER MUST SUPPLY CERTIFICATE. RECYCLED CONTENT

MUST BE AT

LEAST 10% POST-CONSUMER RECOVERED CONTENT. CARPET AND FLOOR ADHESIVE (FOR GLUE-DOWN INSTALLATION MUST

MEET THE

GREEN LABEL PLUS (GLP) AND FLOOR ADHESIVE(FOR DIRECT GLUE-DOWN) REQUIREMENTS OF THE CARPET AND RUG

INSTITUTE (CRI)

GLP NUMBER MUST BE PROVIDED. ADHESIVES MUST MEET VOC CONTENT STANDARDS PER SOUTH COAST AIR QUALITY

MANAGEMENT

DISTRICT RULE #1168.

COMPOSITE WOOD AND AGRIFIBER PRODUCTS, INCLUDING CORE MATERIALS, MUST CONTAIN NO ADDED

UREA-FORMALDEHYDE

RESINS PER LEED CREDIT IEQ4.4

2.02

2.02

2.02

2.02

2.02

2.02

P-5 MFG:

COLOR/NO.:

FINISH:

SHERWIN WILLIAMS

SW7007 CEILING BRIGHT WHITE

FLAT

C 1

VCT 1

BASE:

DOORS:

FRAMES:

WALLS:

CTB-1

BUILDING STANDARD

P-4 P-1

BASE:

DOORS:

FRAMES:

WALLS:

CTB-1

BUILDING STANDARD

P-4

CT-1 TO 48" AFF; P-1 ABOVE

PROVIDE BULLNOSE TOP .

CT-1

CERAMIC WALL TILE

CTB-1

CERAMIC TILE BASE

STYLE:

FINISH:

MFG:

CONTACT:

COLOR:

AMERICAN OLEAN

PROFILES

DESIGNER WHITE

3" X 6"

MATTE

SUSAN MILLEVILLE, 618.444.6949

SIZE:

STYLE:

FINISH/PROFILE:

MFG:

CONTACT:

COLOR:

AMERICAN OLEAN

PROFILES

DESIGNER WHITE

3" X 6"

MATTE, COVED

SUSAN MILLEVILLE, 618.444.6949

SIZE:

2.02

NOTE: REFER TO SHEETS A1.02, A1.03, A1.04, AND A1.05, VA

SPECIFIC GENERAL NOTES, WHICH SUPPLEMENT THE NOTES ON

THIS PAGE. VA SPECIFIC NOTES WITH MORE STRINGENT

S

S

S

S

FE

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

RRR

R R R

RRR

R

N

N

R

R

R

R

RRR

R

R

R

RR

R

R

R

R

R

R

R

R

R

R

RR

R

R

R

R

R

R

R

R

R

R

R

R

R R

R

R

R

R

R

R

N

N

N

N

N

N

N

N

N

N

N

N

N

N

R

N

N N

N

N S

S

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N N

N

N

N

N

N

N

N

N

N N

N

N

N SN3 3

S

N3

N

N

S

N

N

REVISIONS

ALIGNED

STUDIO, LLC

ARCHITECTURE + DESIGN

MISSOURI CERTIFICATE OF AUTHORITY

No. 2016030702

DRAWN BY:

REVIEWED BY:

13100 MANCHESTER

JOB NO.

DATE:

CONTACT:

314.317.0060

SUITE 225

ST. LOUIS, MO 63131

www.aligned-studio.com

OF

CO

NS

TR

UC

TIO

N

DO

CU

ME

NT

S

FO

R:

DE

PA

RT

ME

NT

O

F

VE

TE

RA

NS

' A

FF

AIR

S

RE

AD

JU

ST

ME

NT

C

OU

NS

EL

IN

G

SE

RV

ICE

S

NO

RT

H

OU

TE

R

TO

W N

AN

D

CO

UN

TR

Y, MI

SSO

UR

I 6

MICKI WEHMEIER

micki@aligned-studio.com

RANDY WINZEN

randy@aligned-studio.com

1720.1

11.01.17

A3.01

REFLECTED CEILING

PLAN & SEISMIC

BRACING DETAILS

RCW

RCW

PARTIAL SECOND FLOOR REFLECTED CEILING PLAN

SCALE: 1/8"=1'-0"

REFLECTED CEILING PLAN GENERAL NOTES

1. ALL SHADED AREAS INDICATE "NO WORK" OR "NOT IN CONTRACT" UNLESS OTHERWISE NOTED ON PLAN.

2. PROVIDE NEW 2 X 4 ARMSTRONG CIRRUS SECOND LOOK 15/16" BEVELED TEGULAR CEILING TILE (#513; NRC 0.65) IN EXISTING GRID AT 8'-6" A.F.F. UNLESS OTHERWISE NOTED ON PLAN- REPAIR GRIDS AS REQUIRED. PROVIDE DEDUCT ALTERNATE PRICE TO KEEP EXISTING TILES TO REMAIN. SEE SEISMIC BRACING DETAILS ON SHEET A3.01.

3. PROVIDE NEW DRYWALL CEILINGS AT 8'-6" IN NEW MEN'S RESTROOMS 239 AND WOMEN'S RESTROOM 240.

4. ALL SPRINKLER AND FIRE PROTECTION WORK WILL BE DESIGN BUILD.

5. PROVIDE NEW OR RELOCATE EXISTING EXIT LIGHTS TO MATCH BUILDING STANDARD AND AS REQUIRED BY CODE.

6. ALL RECESSED INCANDESCENT DOWNLIGHTS SHOWN ARE RELOCATED FROM DEMOLITION. RELAMP WITH LED OR

REPLACE AS REQUIRED.

7. INCLUDE ALL NEW SPRINKLER WORK IN CONTRACT. ADD SPRINKLER HEADS AS REQUIRED WITH LIGHTING LAYOUT SHOWN AND TO MEET LOCAL CODES. SPRINKLER HEADS TO BE APPROVED BY BUILDING OWNER/MANAGEMENT.

SPRINKLER HEADS ARE NOT SHOWN ON THIS PLAN.

8. ALL SWITCHES AND DIMMERS (WHERE OCCURS) AT SAME LOCATION SHALL MATCH IN SAME STYLE AND FINISH. DEVICE COLOR SHALL MATCH WHITE. REPLACE ALL DEVICES AND COVER PLATES AS REQUIRED TO MATCH WHITE. LOCATE NEW SWITCHES 6" TO CENTERLINE FROM DOOR JAMB UNLESS OTHERWISE NOTED, OR IF A SIDELIGHT IS SCHEDULED.

7. MECHANICAL ENGINEER TO ENSURE THAT THE SUITE'S MECHANICAL SYSTEM IS DESIGNED AND INSTALLED TO MAINTAIN THERMAL ENVIRONMENTAL CONDITIONS FOR HUMAN OCCUPANCY AS ESTABLISHED BY ASHRAE STANDARD 55-2004.

8. MECHANICAL SYSTEM IS TO BE BALANCED BY A THIRD PARTY LANDLORD-APPROVED AIR BALANCING CONTRACTOR.

9. TIE LIFE SAFETY LIGHTING AND ALARMS INTO BUILDING STANDARD SECURITY SYSTEM.

10. ALL SPRINKLER AND FIRE PROTECTION WORK WILL BE DESIGN BUILD.

11. DIMENSIONS SHOWN ON PLAN FOR 2 X 2 CORRIDOR LIGHTS ARE FOR LIGHTS NOT TOUCHING THREE GRID LINES

ONLY. ALL OTHER LIGHTS SHALL JUST BE PLACED AS THEY ARE LOCATED.

12. RETROFIT ALL EXISTING FLUORESCENT LIGHT FIXTURES WITH T8 ECOLOGIC BULBS. ALL ROOMS EXCEPT WAITING AND RECEPTION SHALL HAVE OCCUPANCY SENSORS. PROVIDE ALTERNATE PRICING FOR NEW LED FIXTURES (LITHONIA

AVANTE AV2 SERIES) THROUGHOUT.

LIGHT FIXTURE SCHEDULE

1 PROVIDE 5/8" DRYWALL CEILINGS IN NEW RESTROOMS AT 8'-6" A.F.F. PAINT DRYWALL CEILING P-5.

WALL SCONCE, DOWN LIGHT(S) AND EXHAUST FAN TO SHALL ALL BE OPERATED BY ONE SWITCH IF POSSIBLE.

PROVIDE NEW CEILING GRID IN THE HATCHED AREA TO MATCH EXISTING IN STYLE, COLOR AND HEIGHT A.F.F.

PROVIDE EXHAUST FAN, 100 CFM (MIN.)- VENT DIRECTLY TO EXTERIOR. EXHAUSTING TO PLENUM IS STRICTLY

PROHIBITED.

PROVIDE GENERAL CORRIDOR SWITCHING IN THIS AREA. ELECTRICAL DESIGN BUILD CONTRACTOR TO

DETERMINE ZONES AND NUMBER OF SWITCHES.

CEILING PLAN KEYED NOTES X

211 234

EARTHQUAKE CLIPS SHALL SECURELY ATTACH THE TROFFER TO

A GRID CEILING. INSTALLS WITH ONE SCREW PER CLIP INTO

PRE-PUNCHED HOLES. CLIPS SHALL MEET NATIONAL

ELECTRICAL CODE AND EARTHQUAKE REQUIREMENTS.

OR

SECURE LIGHT FIXTURES TO GRID CEILING BY MEANS OF

SELF-TAPPING SCREWS AT ALL CORNERS OF FIXTURE.

3.01

SEISMIC BRACING DETAIL

NOT TO SCALE

4'-0"

4'-0"

45 45

SUSPENDED CEILINGS EXCEEDING 1,000 SQUARE FEET IN AREA REQUIRE FOUR NO. 12 GAUGE SPLAY WIRES AND A RIGID VERTICAL COMPRESSION STRUT EVERY 12 FEET ON CENTER STARTING A MAXIMUM OF 6 FEET FROM EACH WALL. THE SPLAY WIRES SHALL BE SECURED TO THE MAIN RUNNER WITHIN 2 INCHES OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING

45 DEGREES FROM THE PLANE OF THE CEILING.

HEAVY DUTY T-BAR CEILING GRID

SUSPENSION SYSTEMLIGHT FIXTURE MUST BE POSITIVELY

ATTACHED TO THE CEILING GRID WITH AN

ATTACHMENT CAPABLE OF CARRYING 100%

OF THE WEIGHT OF THE LIGHT FIXTURE

LIGHT FIXTURES WEIGHING UP TO 56 LBS

REQUIRE TWO VERTICAL SUPPORT WIRES,

THESE WIRES MAY BE SLACK. LIGHT

FIXTURES WEIGHING MORE THAN 56 LBS

SHALL REQUIRE INDEPENDENT SUPPORT

FROM THE SHELL BUILDING STRUCTURE

ABOVE THE CEILING

45 DEGREE 12 GA WIRE BRACING IN PLANE OF MAIN RUNNER,

ALL WIRES ATTACHED TO MAIN RUNNER (4 DIRECTIONS)

SUPPORT WIRES ON THE MAIN AND CROSS RUNNERS A

MAXIMUM DISTANCE OF 8" FROM WALL 4' ON CENTER

SPACING ALONG THE MAIN RUNNER

NOTE:

DETAIL TO OCCUR AT 12'-0" O.C. IN BOTH

DIRECTIONS AND SHOULD OCCUR AT NOT

LESS THAN 4'-0" FROM A SURROUNDING

WALL PER ATSM E580

12 GA. VERTICAL HANGER

WIRE 12'-0" O.C. EACH

DIRECTION, TYP.

MAIN RUNNER

3.01

SEISMIC BRACING DETAIL

NOT TO SCALE

NOTE:

SPRINKLER HEADS AND OTHER PENETRATIONS OF THE SUSPENDED CEILING

SHALL HAVE A 2" OVERSIZE RING, SLEEVE, OR ADAPTOR THROUGH THE CEILING

TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL DIRECTIONS.

CHAIN OR CABLE

12 GA. SUSPENSION WIRE

(TYPICAL) SECURED TO

STRUCTURE

RECESSED LIGHT

FIXTURE

2'X4' ALTERNATE 2'X4' 2'X2'

(FOR UNBRACED

SUSPENSION GRID ONLY)

3.01

SEISMIC BRACING DETAIL

SCALE: 1 1/2"=1'-0"

NOTE: USE THIS DETAIL FOR ALL "NEW" OR "RELOCATED"

LIGHT FIXTURES INSTALLED IN AN EXISTING CEILING GRID

THAT IS NOT SEISMICALLY BRACED. IF EXISTING CEILING GRID

IS SEISMICALLY BRACED, DISREGARD THIS DETAIL.

USE IF ALTERNATE FOR NEW

CEILING GRID IS ACCEPTED

2'-1" 4'-3" 4'-3" 3'-3 1/2"

3'- 6"

3'- 0"

4'-9" 4'-9"

1'-6"

4'- 0"

2'-6

2'-6

TYP

TYP

2'-6"

2'-6"TYP.

TYP.

2'-6

2'-6

TYP

TYP

2'-6" 2'-6"

TYP.

TYP.

2'-6"

2'-6"

TYP.

TYP.

INDOOR ENVIRONMENTAL QUALITY NOTES

MECHANICAL VENTILATION SYSTEMS INSTALLED IN THE SPACE AS A FUNCTION OF THE TENANT FIT-OUT SHALL BE COMPATIBLE WITH THE BUILDING'S BASE SYSTEMS AND MEET OR EXCEED THE MINIMUM REQUIREMENTS OF ASHRAE 62.1-2007

TENANT SHALL ADOPT AN INDOOR AIR QUALITY MANAGEMENT PLAN FOR EXECUTION DURING THE CONSTRUCTION PHASE OF THE

TENANT TIT-OUT THAT COMPLIES WITH LEED CREDIT IEQ3.1

THE CORE AND SHELL INDOOR CONDITIONS COMPLY WITH THE ASHRAE 55-2004, THE STANDARD FOR INDOOR TEMPERATURE AND HUMIDITY CONDITIONS. THE BASE BUILDING HVAC SYSTEMS ARE DESIGNED AND INSTALLED TO SUPPORT ACHIEVING LEED CREDIT IEQ7.1. THE MECHANICAL SYSTEMS THAT ARE ADDED, ADJUSTED, OR SUPPLEMENTED AS PART OF THE TENANT FIT-OUT SHOULD

ENSURE THAT THE STANDARD REFERENCED IS STILL BEING MET.

THERMAL COMFORT RANGES ARE AS FOLLOWS:

1. TEMPERATURE RANGE : (70-75 DEGREES)+/-2 DEGREES IN SUMMER, (68-72 DEGREES )+/- IN WINTER.

2. HUMIDITY RANGE: 55%+/-, 10% SUMMER, 30% +/- 10% IN WINTER

3. ZONE CONTROL: ALL THERMOSTATS AND HUMIDITY SENSORS ARE LOCATED IN THE ZONE SERVED.

ACOUSTICAL REQUIREMENTS

A. REVERBERATION CONTROL: PRIVATE OFFICE AND CONFERENCE ROOMS USING SUSPENDED ACOUSTICAL CEILINGS SHALL HAVE A NOISE REDUCTION COEFFICIENT (NRC) OF NOT LESS THAN 0.65 IN ACCORDANCE WITH ASTM C-423. OPEN OFFICE USING

SUSPENDED ACOUSTICAL CEILINGS SHALL HAVE AN NRC OF NOT LESS THAN 0.75.

B. AMBIENT NOISE CONTROL: AMBIENT NOISE FROM MECHANICAL EQUIPMENT SHALL NOT EXCEED NOISE CRITERIA CURVE (NC) 35 IN ACCORDANCE WITH THE ASHRAE HANDBOOK OF FUNDAMENTALS IN OFFICES AND CONFERENCE ROOMS. NC 40 I CORRIDORS, CAFETERIAS, LOBBIES, AND RESTROOMS. NC 50 IN OTHER SPACES.

C. NOIsE ISOLATION: ROOMS SEPARATED FROM ADJACENT SPACES BY CEILING HIGH PARTITIONS (NOT INCLUDING DOORS SHALL HAVE NOT LESS THAN THE FOLLOWING NOISE ISOLATION CLASS (NIC) STANDARDS WHEN TRSTED IN ACCORDANCE WITH ATSM E-336.

OCCUPANCY/VACANCY SENSORS

PROVIDE AND INSTALL CEILING MOUNTED OCCUPANCY SENSORS OR VACANCY SENSORS (PREFERRED) OR SCHEDULING CONTROLS THROUGH THE BUILDING AUTOMATION SYSTEM (BAS) THROUGHOUT THE SUITE IN ORDER TO REDUCE THE HOURS THAT THE LIGHTS ARE ON WHEN A PARTICULAR SPACE IS UNOCCUPIED. NO MORE THAN 1000 SQUARE FEET SHALL BE CONTROLLED BY ANY ONE SENSOR. OCCUPANCY SENSORS IN ENCLOSED ROOMS SHALL CONTINUE TO OPERATE AFTER THE BAS HAS SHUT DOWN THE BUILDING AT THE END OF THE WORK DAY. SWITCHES SHOWN IN PLAN ARE MANUAL OVERRIDES. EXISTING SWITCH LOCATIONS

SHALL BE CHANGED TO MANUAL OVERRIDES.

NOTE: REFER TO SHEETS A1.02, A1.03, A1.04, AND A1.05, VA

SPECIFIC GENERAL NOTES, WHICH SUPPLEMENT THE NOTES ON

FE

T

+84 +84

S

+4

+4 4+4

+44

N

N

N

N

N

N

N N

N N

N

NN

N N

NN

N

N

NN

N +44 N +44

N N

N

N N

N

N N

N

N

N

NN

N

N N

N

N N

N

N

N

N

N

N

NN

N

N

N

N

N

N N

N N

DEDN

N +44

N +44

N + 44N +

N

N

N+66"

N N

N+66" N+66"

N+66" N+66" N+66"

N+ 66"

N+ 66"

N+ 66"N

N

N +

N

N N

N

N

N

N GFI

N GFI

N N

N

N

N N N

DEDMW

NN

N

N

N

REF.

REVISIONS

ALIGNED

STUDIO, LLC

ARCHITECTURE + DESIGN

MISSOURI CERTIFICATE OF AUTHORITY

No. 2016030702

DRAWN BY:

REVIEWED BY:

13100 MANCHESTER

JOB NO.

DATE:

CONTACT:

314.317.0060

SUITE 225

ST. LOUIS, MO 63131

www.aligned-studio.com

OF

CO

NS

TR

UC

TIO

N

DO

CU

ME

NT

S

FO

R:

DE

PA

RT

ME

NT

O

F

VE

TE

RA

NS

' A

FF

AIR

S

RE

AD

JU

ST

ME

NT

C

OU

NS

EL

IN

G

SE

RV

ICE

S

NO

RT

H

OU

TE

R

TO

W N

AN

D

CO

UN

TR

Y, MI

SSO

UR

I 6

MICKI WEHMEIER

micki@aligned-studio.com

RANDY WINZEN

randy@aligned-studio.com

1720.1

11.01.17

A3.02

POWER PLAN &

SEISMIC BRACING

DETAILS

RCW

RCW

PARTIAL SECOND FLOOR POWER PLAN

SCALE: 1/8"=1'-0"

POWER PLAN GENERAL NOTES

1. ALL SHADED AREAS INDICATE "NO WORK" OR "NOT IN CONTRACT" UNLESS OTHERWISE NOTED ON PLAN.

2. COORDINATE EXACT LOCATIONS AND REQUIREMENTS OF TENANT PROVIDED FURNITURE COMMUNICATION / ELECTRICAL IN-FEEDS AND WITH TENANT FURNITURE VENDOR PRIOR TO START OF CONSTRUCTION. VERIFY

FLOOR BOX LOCATIONS AND X-RAY SLAB AS REQUIRED.

3. ALL DEVICES ARE EXISTING EXCEPT THOSE DENOTED AS "N" NEW OR "R" RELOCATED. EXISTING

LOCATIONS TO REMAIN UNLESS NOTED OTHERWISE, AND ARE NOT SHOWN ON THIS PLAN.

4. NEW DEVICE AND COVER PLATE COLOR SHALL BE WHITE.

5. ALL CABLING SHALL BE INSTALLED WITH CONDUIT END TO END.

6. PROVIDE AND INSTALL G.F.I. TYPE OUTLETS NEAR WATER SOURCES PER CODE.

7. ALL CABLE WITHIN CEILING CAVITY SHALL BE PLENUM RATED.

8. PROVIDE AND INSTALL 1/2 HP GARBAGE DISPOSAL AND SWITCH.

9. PROVIDE AND INSTALL NEW APPLIANCES INCLUDING ALL ELECTRICAL HOOK-UPS AND DRAINS:

(1) REFRIGERATOR WITH ICEMAKER

(1) MICROWAVE

(1) DISHWASHER

(1) GARBAGE DISPOSAL

APPLIANCES SHALL BE ENERGY STAR RATED. PROVIDE CUT SHEETS FOR TENANT APPROVAL

10. COORDINATE WITH MEP ENGINEER FOR NEW ELECTRICAL PANEL LOCATIONS. EXISTING PANELS TO BE REMOVED DURING DEMOLITION. COORDINATE TEMPORARY POWER TO SUITE FOR USE DURING CONSTRUCTION.

1 PROVIDE CONDUIT FOR CABLE TV AND PULL STRING AT WALL MOUNTED TV BY TENANT.

PROVIDE FLUSH FLOOR DEVICE WIREMOLD-LAGRANGE AV6 SERIES OR EQUAL. VERIFY LOCATIONS AND ALL

REQUIREMENTS WITH TENANT.

TWO POSSIBLE NEW LOCATIONS FOR EXISTING ELECTRIC PANEL SAVED FROM DEMOLITION- EXACT LOCATION TO

BE DETERMINED BY ELECTRICAL DESIGN BUILD CONTRACTOR.

POWER PLAN KEYED NOTES X

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

SES DIRECTOR

OFFICE

CONFERENCE

WORK RM.

TOILET

TOILET

OFFICE

OFFICE

OFFICE

NETWORK

OFFICE

BREAK

ROOM

STOR.

WAITING

COATS

CORRIDOR

CORR.

CORR.

CORR.

CORR.

CORR.

RECEPTION

BUILDING

CORRIDOR

STOR.

CORR.

CORR.

OFFICE

OFFICE

TRAINING/

MULTIPURPOSE

METAL STUD LATERAL BRACING - SCREW ATTACH TO TOP RUNNER

OF PARTITION AND UNDERSIDE OF FLOOR DECK ABOVE WITH (2)

#6 SCREWS AT EACH CONNECTION. CUT AND FOLD STUD WEB AS

NECESSARY FOR CONNECTIONS.

ACOUSTIC CEILING

THIS DETAIL TO BE USED AT ALL 'NEW' PARTITIONS - ALL

PARTITIONS MUST BE BRACED AT 12'-0" O.C.

3.02

SEISMIC BRACING DETAIL

SCALE: 1 1/2"=1'-0"

3'-

4'- 0"

6'- 8"

1"

4"

12"

4'- 0"

3'- 2"

ROLLER LATCHAUDIBLE / VISUAL ALARMS

FIRE EXTINGUISHER

CABINET

POWER / COMMUNICATION

DEVICES (SWITCHES - SIMILAR)

TELEPHONE: MOUNT HIGHEST

OPERABLE PART AT 48" A.F.F.

THERMOSTAT

SWITCH: DASHED LINE INDICATES

LOCATION OF LARGER PLATE FOR

GANGED SWITCHES

DOOR HANDLE

CARD READER

NOTE:

ALL MOUNTING HEIGHTS SHALL

MEET ADA REQUIREMENTS.

MATCH EXISTING HEIGHTS

WHERE POSSIBLE

TYPICAL MOUNTING HEIGHTS

NOT TO SCALE

3.02

SEISMIC BRACING DETAIL

NOT TO SCALE

3.02

ACOUSTICAL CEILING TILE- CUT AS

REQUIRED TO ALLOW LATERAL

BRACING TO INDEPENDENTLY

INTERSECT PARTITION TOP TRACK

PARTITION TOP TRACK

CEILING TEE

NOTE:

ALL WALL PARTITIONS GREATER THAN 6' IN HEIGHT

SHALL BE INDEPENDENTLY BRACED TO THE BUILDING

SHELL STRUCTURE. WALL PARTITIONS MAY NOT BE

SUPPORTED BY THE BRACED SUSPENDED CEILING ALONE.

METAL STUD LATERAL BRACING - SCREW ATTACH TO TOP RUNNER

OF PARTITION AND UNDERSIDE OF FLOOR DECK ABOVE WITH (2)

#6 SCREWS AT EACH CONNECTION. CUT AND FOLD STUD WEB AS

NECESSARY FOR CONNECTIONS.

PARTITION

3.02

METAL STUD LATERAL BRACING - SCREW ATTACH TO TOP

RUNNER OF PARTITION AND UNDERSIDE OF FLOOR DECK

ABOVE WITH (2) #6 SCREWS AT EACH CONNECTION. CUT

AND FOLD STUD WEB AS NECESSARY FOR CONNECTIONS.

ACOUSTIC CEILING

THIS DETAIL TO BE USED AT ALL

'NEW' PARTITIONS - ALL PARTITIONS

MUST BE BRACED AT 12'-0" O.C.

3.02

SEISMIC BRACING DETAIL

SCALE: 1 1/2"=1'-0"

3.02

3.02

ENLARGED NETWORK ROOM PLAN

SCALE: 1/2"=1'-0"

NETWORK

DED

N

DED

+65

(VERIFY)

8'-7"+/-

3'- 2"

1'- 5"

7'-8"

11"+/-

5'-

1/ 4"

1'-5"

6'-0" X 4'-0" X 3/4" TREATED

PLYWOOD PHONE BOARD

RELOCATED SERVER

RACK

RELOCATED WALL MOUNTED

SUPPLEMENTAL HVAC UNIT

2 2

NOTE: ANY NEW OR EXISTING PARTITION THAT HAS A CONTINUOUS UNINTERRUPTED

RUN OF OVER 12'-0" IN LENGTH IS REQUIRED TO HAVE THE TOP OF THE PARTITION

SEISMICALLY BRACED TO THE STRUCTURE ABOVE WITH METAL STUD KICKERS PER THE

DETAILS PROVIDED ON THE DRAWINGS. ANY WALLS WITH INTERSECTING

PERPENDICULAR PARTITIONS AT INTERVALS OF LESS THAT 12'-0" CAN ELIMINATE THE

KICKERS AND ARE NOT REQUIRED TO BE SEISMICALLY BRACED.

NOTE: REFER TO SHEETS A1.02, A1.03, A1.04, AND A1.05, VA

SPECIFIC GENERAL NOTES, WHICH SUPPLEMENT THE NOTES ON

1'- 5"

3'- 0"

BA

R

1'-

6" BA

R

4"

8'- 6"

1'-6" 1'-6"

2'-

6'- 6"

4.01

MEN'S ADA RESTROOM 239

SCALE: 3/8"=1'-0"

4.01 SCALE: 3/8"=1'-0"

9'-6" 8'-0"

8'-

6"GRAB BARS GRAB BARS

TOILET PAPER

DISPENSER

TOILET PAPER

DISPENSER

NEW ADA COMPLIANT

WALL MOUNTED TOILET

NEW ADA COMPLIANT

WALL MOUNTED TOILET

NEW WALL MOUNTED

LAVATORY

BOBRICK 24" X 40", CLEAR TEMPERED

MIRROR IN TOP AND BOTTOM GLAZING

CHANNELS WITH 4" SHELF

INSULATE PIPES

BELOW

MEN'S ADA RESTROOM 239

4'- 0"

CERAMIC TILE

WAINSCOT- TYPICAL

REVISIONS

ALIGNED

STUDIO, LLC

ARCHITECTURE + DESIGN

MISSOURI CERTIFICATE OF AUTHORITY

No. 2016030702

DRAWN BY:

REVIEWED BY:

13100 MANCHESTER

JOB NO.

DATE:

CONTACT:

314.317.0060

SUITE 225

ST. LOUIS, MO 63131

www.aligned-studio.com

OF

CO

NS

TR

UC

TIO

N

DO

CU

ME

NT

S

FO

R:

DE

PA

RT

ME

NT

O

F

VE

TE

RA

NS

' A

FF

AIR

S

RE

AD

JU

ST

ME

NT

C

OU

NS

EL

IN

G

SE

RV

ICE

S

NO

RT

H

OU

TE

R

TO

W N

AN

D

CO

UN

TR

Y, MI

SSO

UR

I 6

MICKI WEHMEIER

micki@aligned-studio.com

RANDY WINZEN

randy@aligned-studio.com

1720.1

11.01.17

A4.01

ENLARGED PLANS

AND INTERIOR

ELEVATIONS

RCW

RCW

ENLARGED RESTROOM PLANS

SCALE: 3/8"=1'-0"

4.01

8'- 0"

1'- 0"

8'- 7"

3'-4"

4'-2" 3 3/4" 9'-6"+/-

9'- 0"

3/ 4"

7'-

1/ 2"

2'-0"+/-

5'-

1/ 2"

13'-10 1/2"+/-

1'-6" 7'-6"

1'-6" 1'-6"

2'-6 1/2"+/-

1'-6" (MIN.)

4.01

4.01 2

4.01 4

4.01

ADA

MEN

ADA

WOMEN

CORR.

CORR.

3 2

F

F

3/ 4"

1'-

1/ 4"

3'-0"

BAR

6"

PAPER TOWEL DISPENSER

AND DISPOSAL

4'-3" 1'- 5"

3'- 0"

BA

R

4" 1'-

6" BA

R

3'-6"

BAR

1'-0"

3'-4"

3'-0"

1'- 7"

3'-6"

BAR

1'-0"

3'-4"

2'- 6"

10"

4.01 SCALE: 3/8"=1'-0"

8'-7"

8'- 6"

TOILET PAPER

DISPENSER

WOMEN'S ADA RESTROOM 240

4'- 0"

CERAMIC TILE

WAINSCOT- TYPICAL

1'- 5"

3'- 0"

BA

R

1'-

6" BA

R

4" 8'-

6"

1'-6"

7'-6"

2'-

6'- 6"

4.01

WOMEN'S ADA RESTROOM 240

SCALE: 3/8"=1'-0"

13'-10 1/2"+/-

GRAB BARS

TOILET PAPER

DISPENSER

NEW ADA COMPLIANT

WALL MOUNTED TOILET

NEW WALL MOUNTED

LAVATORY

INSULATE PIPES

BELOW

CERAMIC TILE

WAINSCOT- TYPICAL

3'-0"

BAR

6"

PAPER TOWEL DISPENSER

AND DISPOSAL

5'-0"

1'-6"

GRAB BARS

NEW ADA COMPLIANT

WALL MOUNTED TOILET

1'- 5"

3'- 0"

BA

R

4" 1'-

6" BA

R

CERAMIC TILE

WAINSCOT- TYPICAL

FEMININE NAPKIN

DISPOSAL

5'-8 3/4" 2'-6" 2'-9" 2'-6" 1 1/2"

1'-1"

14'-8 1/4"

2'-6" 1'-9" 2'-6" 2 1/2"

2'-0"

3'- 0"

1'- 8"

2'- 6"

1'- 4"

8'-

6" PLASTIC LAMINATE

COUNTERTOP

PLASTIC LAMINATE WALL CABINETS

WITH ADJUSTABLE SHELVES

PLASTIC LAMINATE BASE CABINETS

WITH ADJUSTABLE SHELF

FILLER

FINISHED END

PANEL

DRAWER UNIT

FINISHED END

PANEL

4.01 SCALE: 3/8"=1'-0"

WORK ROOM 221

9'-8 1/2"

1'-1" 1 3/4"

2'-6" 2'-3" 2'-6" 1 3/4"

1'-1"

3'- 0"

1'- 8"

2'- 6"

1'- 4"

2'-0" 1 1/4"

2'-9" 2'-9" 1 1/4"

2'-0"

FILLER

PLASTIC LAMINATE

COUNTERTOP

PLASTIC LAMINATE BASE

CABINETS WITH

ADJUSTABLE SHELF

PLASTIC LAMINATE WALL

CABINETS WITH

ADJUSTABLE SHELVES

FILLER 8'-

6"

4.01 SCALE: 3/8"=1'-0"

WORK ROOM 221

2'-6"2'-9"2'-6" 1 1/2"

1'-1"

14'-8 1/4"

2'-6"1'-9"2'-6" 2 1/2"

2'-0"

3'- 0"

1'- 8"

2'- 6"

1'- 4"

8'- 6"

PLASTIC LAMINATE

COUNTERTOP

PLASTIC LAMINATE WALL CABINETS

WITH ADJUSTABLE SHELVES

PLASTIC LAMINATE BASE CABINETS

WITH ADJUSTABLE SHELF

FILLER

DRAWER UNIT

7/8"

FILLER

7/8" 1'-4" 4'-4"+/-

FILLER

4.01 SCALE: 3/8"=1'-0"

WORK ROOM 221

KEYED NOTES #

ADA COMPLIANT ELECTRIC SENSOR FAUCET: KOHLER OR EQUAL

WALL MOUNTED WATER CLOSET MOUNTED AT 17" A.F.F. TO RIM: KOHLER OR EQUAL,

ELONGATED, COLOR- WHITE WITH BATTERY OPERATED FLUSH VALVE.

WALL MOUNTED SINK MOUNTED AT 34" A.F.F.: KOHLER OR EQUAL

TOILET PAPER DISPENSER: BOBRICK OR EQUAL SURFACE MOUNTED MULTI-ROLL TOILET

TISSUE DISPENSER IN SATIN STAINLESS STEEL FINISH.

FEMININE NAPKIN DISPOSAL: BOBRICK OR EQUAL SURFACE MOUNTED SANITARY NAPKIN

DISPOSAL IN SATIN STAINLESS STEEL FINISH.

BOBRICK #B-5806 X 18- 18" STRAIGHT GRAB BAR IN SATIN STAINLESS STEEL FINISH.

BOBRICK #B-5806 X 36- 36" STRAIGHT GRAB BAR IN SATIN STAINLESS STEEL FINISH.

BOBRICK #B-5806 X 42- 42" STRAIGHT GRAB BAR IN SATIN STAINLESS STEEL FINISH.

NEW FLOOR DRAIN- SEE PLUMBING DESIGN BUILD DRAWINGS.

FRAMELESS 24" X 48" MIRROR- VERIFY EXACT REQUIREMENTS WITH TENANT.

ALIGN NEW CONSTRUCTION WITH EXISTING IN SAME PLANE WITH NO VISIBLE JOINTS.

ADA ACCESSIBLE SEMI RECESSED PAPER TOWEL DISPENSER AND RECEPTACLE: BOBRICK

OR EQUAL.

WALL MOUNTED SOAP DISPENSER WITH ELECTRIC SENSOR- BOBRICK OR EQUAL.

4.01 SCALE: 3/8"=1'-0"

TYPICAL DOOR & SIDELIGHT

2"3'-0"2" 10" 1'-6"

7'- 2"

DOOR HEIGHT TEMPERED

GLASS SIDELIGHT

TYPICAL OFFICE DOOR

2"

TYP.

4.01

DETAIL AT COAT ROD AND SHELF

SCALE: 1 1/2"=1'-0"

1'-0" 6"

NOTE: A.D.A. INCLUDES HOOK AT

48" A.F.F. AT EACH SIDE WALL

SEE PARTITION TYPES

3/4" BIRCH VENEER PLYWOOD

(PAINT TO MATCH WALL)

1 x 4 HARDWOOD EDGE

(PAINT TO MATCH WALL)

KNAPE & VOGT #770 1 1/16" O.D.

TUBING WITH #734 AND #735

BRACKETS (TYPICAL) OR EQUAL

METAL ROD/SHELF BRACKET AT C.L. OF SPAN (SPANS

OVER 6'-0": SPACE AT 3'-0" O.C. MAXIMUM)

1 x NO. 1 GRADE (PAINT TO MATCH WALL)

COUNTERSINK SCREWS AND CONCEAL

2 x 4 FIRE RETARDANT TREATED WOOD

BLOCKING SECURE TO STUDS

1/ 4"

5'- 6"

A .F.

F.

3'- 0"

2"

2x FIRE RETARDANT TREATED

WOOD BLOCKING IN PARTITION

SCHEDULED PLASTIC LAMINATE OR SOLID

SURFACE COUNTERTOP AND BACKSPLASH

(WHERE APPLICABLE)

1/ 2"

SCHEDULED PLASTIC LAMINATE

EXTERIORS ALL EXPOSED SURFACES

INTERIORS WHITE MELAMINE

4"

3"

SCHEDULED PLASTIC

LAMINATE TOE KICK

6" 6"

6" 1'-

1/ 2"

18" DRAWER DEPTH - TYPICAL

2'-1"

1/2"

NOTE:

SCRIBE ALL MILLWORK TO

ADJACENT SURFACES

4.01

SECTION AT BASE CABINET

SCALE: 1"=1'-0" DRAWER UNIT

4.01

SECTION AT BASE CABINET

SCALE: 1"=1'-0" WITH DRAWER

2x FIRE RETARDANT TREATED

WOOD BLOCKING IN PARTITION

SCHEDULED PLASTIC LAMINATE

OR SOLID SURFACE

COUNTERTOP AND BACKSPLASH

(WHERE APPLICABLE)

2"

2'-1"

3/4"1'-10"

6" 1 1/ 2"

INTERIORS WHITE MELAMINE

PROVIDE (1) 18" DEEP

ADJUSTABLE SHELF WITH HAFELE

#282.04.711 SHELF SUPPORTS

AND HOLES AT 3" O.C. SPACING

SCHEDULED PLASTIC

LAMINATE TOE KICK

4"

3"

NOTE:

SCRIBE ALL MILLWORK TO

ADJACENT SURFACES

SCHEDULED PLASTIC

LAMINATE EXTERIORS ALL

EXPOSED SURFACES

3/4"1/2"

2x FIRE RETARDANT TREATED

WOOD BLOCKING IN PARTITION

1'-1"

12"1/4"

2'- 6"

(S

EE

IN

TE

RIO

R

EL

EV

AT

IO

NS

PROVIDE (2) 11" DEEP ADJUSTABLE

SHELVES WITH HAFELE #282.04.711

SHELF SUPPORTS AND HOLES AT 1" O.C.

SPACING

PLASTIC LAMINATE EXTERIOR AND

TWO SIDES AND ALL EDGES

INTERIOR: WHITE MELAMINE

COUNTERTOP BELOW (WHERE OCCURS)

4.01

SECTION AT WALL CABINET

SCALE: 1"=1'-0"

W

HE

RE

C

OU

NT

ER

TO

P

EX

IST

S

1'-1"

VERIFY SOFFIT DEPTH

2'-

4"

SCHEDULED PLASTIC LAMINATE OR SOLID

SURFACE COUNTERTOP AND BACKSPLASH

18" REMOVABLE (LIFT OFF) ADA FRONT PANEL-

LOCATE FOR MAXIMUM CLEARANCE BELOW.

HARDWARE: BULLDOG CABINET CATCH #655

8"

MIN.

11"

MIN.

2'- 5"

1'-5"

9"

5"

1'- 6"

REQUIRED ADA KNEE CLEARANCE (SHOWN HATCHED)

REQUIRED ADA TOE CLEARANCE (SHOWN HATCHED)

GARBAGE DISPOSAL: INSINKERATOR

BADGER 5

2"

PLASTIC LAMINATE BACK PANEL

NOTE: CONTRACTOR TO VERIFY REQUIRED

ADA TOE AND KNEE CLEARANCES AT

TIME OF FABRICATION/INSTALLATION

6"

MAX.

NOTE:

SCRIBE ALL MILLWORK TO ADJACENT SURFACES

2x FIRE RETARDANT TREATED

WOOD BLOCKING IN PARTITION

2'-1"

ELKAY GECR-2521 L OR R

STAINLESS STEEL SINK WITH GOOSENECK

FAUCET AND LEVER STYLE HANDLES

NOTE:

SCRIBE ALL MILLWORK

TO ADJACENT SURFACES

1/ 2"

4.01

SECTION AT SINK CABINET

SCALE: 1"=1'-0"

3'- 0"

SCHEDULED CEILING

(5) 15" DEEP x 3/4" THICK HIGH

DENSITY FIBERBOARD SHELVES WITH

MELAMINE FINISH ALL SIDES

KNAPE & VOGT 87 SERIES SUPER DUTY STANDARDS AT

32" O.C. (2" VERTICAL ADJUSTMENT SLOTS) WITH KNAPE

& VOGT 187 SUPER DUTY METAL SHELF BRACKETS

SCHEDULED BASE

SCHEDULED FLOOR FINISH

3/4" FIRE RETARDANT TREATED PLYWOOD OR 2x4 FIRE

RETARDANT TREATED BLOCKING BETWEEN STUDS. SECURE

TO STUDS AT TOP MIDDLE, AND BOTTOM OF WALL

4.01

SECTION AT ADJUSTABLE SHELVES

SCALE: 1"=1'-0"

8'- 6"

V

ER

IFY

1/ 2"7"1'-0"

2'-1"

2"

8" WIDE FIRE RETARDANT TREATED

PLYWOOD BLOCKING IN PARTITION

SCHEDULED PLASTIC LAMINATE

COUNTERTOP AND BACKSPLASH

6"

SCHEDULED BASE

'L' FLOOR CLIP. SET IN

MORTISE IN PANEL

INTERMEDIATE PLASTIC LAMINATE

SUPPORT PANEL AT 4'-0" O.C.

MAX. SEE PLAN WHERE OCCURS

3/4" x 3/4" HARDWOOD CLEAT

4.01

SECTION AT COUNTERTOP

SCALE: 1"=1'-0"

NOTE: PROVIDE ONLY THREE DRAWERS

IN…