A1.05
VA SPECIFIC
GENERAL
NOTES
MSW
RCW
REVISIONS
ALIGNED
STUDIO, LLC
ARCHITECTURE + DESIGN
MISSOURI CERTIFICATE OF AUTHORITY
No. 2016030702
DRAWN BY:
REVIEWED BY:
13100 MANCHESTER
JOB NO.
DATE:
CONTACT:
314.317.0060
SUITE 225
ST. LOUIS, MO 63131
www.aligned-studio.com
OF
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
FO
R:
DE
PA
RT
ME
NT
O
F
VE
TE
RA
NS
' A
FF
AIR
S
RE
AD
JU
ST
ME
NT
C
OU
NS
EL
IN
G
SE
RV
ICE
S
NO
RT
H
OU
TE
R
TO
W N
AN
D
CO
UN
TR
Y, MI
SSO
UR
I 6
MICKI WEHMEIER
micki@aligned-studio.com
RANDY WINZEN
randy@aligned-studio.com
1720.1
11.01.17
S
S S
S
S S
S
S
J
T
S
+44
+44 +44
S
S
S
S
S
S
S
S
S
S
S
SSS
S
T
FE
FE
T
T
T
T
+44
+44
+44
+44
DED
J
J +81
EP
REVISIONS
ALIGNED
STUDIO, LLC
ARCHITECTURE + DESIGN
MISSOURI CERTIFICATE OF AUTHORITY
No. 2016030702
DRAWN BY:
REVIEWED BY:
13100 MANCHESTER
JOB NO.
DATE:
CONTACT:
314.317.0060
SUITE 225
ST. LOUIS, MO 63131
www.aligned-studio.com
OF
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
FO
R:
DE
PA
RT
ME
NT
O
F
VE
TE
RA
NS
' A
FF
AIR
S
RE
AD
JU
ST
ME
NT
C
OU
NS
EL
IN
G
SE
RV
ICE
S
NO
RT
H
OU
TE
R
TO
W N
AN
D
CO
UN
TR
Y, MI
SSO
UR
I 6
MICKI WEHMEIER
micki@aligned-studio.com
RANDY WINZEN
randy@aligned-studio.com
1720.1
11.01.17
A2.00
DEMOLITION PLAN
& DOOR DETAILS
RCW
RCW
PARTIAL SECOND FLOOR DEMOLITION PLAN
SCALE: 1/8"=1'-0"
DEMO/REMOVE EXISTING PARTITION INCLUDING ALL ELECTRICAL/ DATA WIRING/CABLING BACK TO ITS
SOURCE PANEL.
DEMO/REMOVE EXISTING DOOR AND FRAME AS REQUIRED. SALVAGE FOR REUSE IN NEW DESIGN, TURN
OVER TO BUILDING STOCK OR DISPOSE OF AS DIRECTED BY OWNER.
DEMO/REMOVE EXISTING GLASS BORROW LIGHT AND FRAME (WHERE APPLICABLE).
REMOVE EXISTING CEILING TILE AND GRIDS IN HATCHED AREA. PROVIDE SUPPORT TO ANY GRIDS TO
REMAIN AND PREPARE FOR NEW PARTITIONS TO BE ERECTED.
DEMO/REMOVE EXISTING SHELVING, CASEWORK AND COUNTERTOPS INCLUDING ALL ELECTRICAL/ DATA
WIRING/CABLING BACK TO ITS SOURCE PANEL.
DEMO/REMOVE EXISTING PLUMBING FIXTURE INCLUDING ALL ASSOCIATED PIPING AND DRAIN LINES TO BELOW SLAB OR BEHIND EXISTING WALLS TO REMAIN. PATCH ALL REMAINING SURFACES AND PREPARE
TO RECEIVE NEW FINISHES.
DEMO/REMOVE EXISTING ELECTRICAL/DATA ITEM INCLUDING ALL WIRING/CABLING BACK TO ITS SOURCE
PANEL- PATCH REMAINING WALL/FLOOR SURFACES AND PREPARE TO RECEIVE NEW FINISHES.
DEMO/REMOVE EXISTING PHONE BOARD AND/OR SERVER RACK AND ALL ASSOCIATED EQUIPMENT, CABLING, CONDUIT AND ELECTRICAL ITEMS. HOLD RACK IN A PROTECTED LOCATION FOR REUSE IN NEW
LAYOUT.
DEMO/REMOVE EXISTING ELECTRIC PANEL AND HOLD FOR RELOCATION IN NEW LAYOUT. REROUTE ALL WIRING AS POSSIBLE TO NEW LOCATION OR REPORT TO BUILDING MANAGEMENT IF REROUTING IS NOT
POSSIBLE.
EXISTING BUILDING COLUMN TO REMAIN- REDUCE BUILD OUT SIZE TO AS SMALL AS POSSIBLE AND
PROTECT DURING CONSTRUCTION.
CUT HOLE IN FLOOR TO ACCOMMODATE NEW SPRINKLER RISER (APPROX. 6" DIA.)- VERIFY EXACT SIZE AND LOCATION WITH SPRINKLER CLOSET ON FLOOR BELOW AND WITH FIRE PROTECTION CONTRACTOR.
DEMO EXISTING WALL MOUNTED SUPPLEMENTAL HVAC UNIT AND STORE IN PROTECTED AREA FOR
RELOCATION.
DEMO/REMOVE EXISTING PLUMBING FIXTURE. TEMPORARILY CAP OFF PLUMBING LINES AND PREPARE
FOR REROUTE TO NEW SPECIFIED SINK.
1. ALL SHADED AREAS INDICATE "NO WORK" OR "NOT IN CONTRACT" UNLESS OTHERWISE NOTED ON PLAN.
2. REMOVE ALL EXISTING AREAS INDICATED AS DEMOLITION TO PROVIDE LAYOUT SHOWN. CONSTRUCT AND/OR PROVIDE PROTECTION BARRIERS AS NEEDED FOR SAFETY AND TO CONTAIN DUST DUE TO DEMOLITION AND KEEP
BUILDING SECURE AND WEATHER TIGHT DURING THE CONSTRUCTION PERIOD.
3. PATCH AND REPAIR REMAINING SURFACES AS NEEDED DUE TO THE DEMOLITION OR THE REMOVAL OF
CONSTRUCTION.
4. REPAIR HOLES IN EXISTING PARTITIONS TO REMAIN WHERE PARTITION MOUNTED ITEMS ARE TO BE REMOVED. REFER TO FINISH PLAN FOR SCHEDULED FINISH. WHERE PARTITION, EQUIPMENT OR ACCESSORIES, ETC. ARE REMOVED AND NO REPLACEMENT FINISH IS CALLED FOR, PATCH AND REPAIR TO MATCH ADJACENT
FINISH.
5. REMOVE ALL DEMOLISHED MATERIALS FROM THE BUILDING AND THE SITE. ALL DEMOLISHED MATERIALS, EXCEPT AS NOTED, ARE THE PROPERTY OF THE GENERAL CONTRACTOR.
6. REMOVE ANY AND ALL EXISTING ELECTRICAL AND COMMUNICATION EQUIPMENT, SWITCHES, RECEPTACLES, NOT SHOWN ON THE DRAWINGS AND THAT ARE NOT IN USE IN AREAS OF WORK FROM WITHIN PARTITIONS AND ABOVE THE SCHEDULED CEILING. ALL WIRING SHALL BE REMOVED BACK TO ITS SOURCE PANEL.
COORDINATE WITH THE BUILDING CONSTRUCTION MANAGER.
7. SALVAGE AND STORE EXISTING DOORS AND FRAMES AND OTHER ITEMS CALLED OUT TO BE RELOCATED.
MODIFY AS REQUIRED. REPAIR ANY DAMAGE TO ALL EXISTING SURFACES AND ITEMS BEING SALVAGED FOR REUSE. RETURN UNUSED MATERIALS TO BUILDING STORAGE AS DIRECTED BY BUILDING MANAGEMENT.
8. REMOVE ALL FINISHES AND CASEWORK THROUGHOUT SUITE EXCEPT AS NOTED ON PLAN.
9. ALL PLUMBING TO BE REMOVED BELOW SLAB. REPAIR EXISTING SLAB AS REQUIRED TO MEET ALL LOCAL
CODES.
10. REMOVE ALL CEILING TILES (UNLESS DEDUCT ALTERNATE TO KEEP EXISTING TILE IS SELECTED), AND LIGHTING THROUGHOUT SUITE (ONLY IF NEW LED LIGHTS ARE SELECTED IN LIEU OF RETROFITTING EXISTING
LIGHTS - SEE SHEET A3.01) AND PREPARE FOR NEW CEILING TILES AND LED LIGHTING.
DEMOLITION PLAN GENERAL NOTES
DEMOLITION PLAN KEYED NOTES
1 1
2 2
1.03
HOLLOW METAL HEAD DETAIL
SCALE: 3"=1'-0"
5/ 8"
2"
1/2" 1/2"
HOLLOW METAL FRAME - PAINT
DOOR LEAF
DOOR SILENCER
(3) PER LEAF
5/8" 2"
1/ 2"
1/ 2"
3 ANCHORS PER JAMB
DOUBLE JAMB STUDS
SE
E
PA
RT
ITI
ON
TY
PE
S
DOOR LEAF
DOOR SILENCER
(3) PER LEAF
NOTE: STRIKE JAMB SHOWN: HINGE JAMB SIMILAR
1.03
HOLLOW METAL JAMB DETAIL
HOLLOW METAL FRAME - PAINT
SCALE: 3"=1'-0"
2"
VE
RIF
Y"
2"
1/2" SEE PARTITION
TYPES
1/2"
HOLLOW METAL FRAME - PAINT
SEALANT
REMOVABLE STOP
1/4" CLEAR TEMPERED GLASS
HOLLOW METAL FRAME - PAINT
FIRE RETARDANT TREATED WOOD
BLOCKING - FASTENED TO FLOOR
FINISHED FLOOR
1.03
HOLLOW METAL SIDELIGHT DETAIL
SCALE: 3"=1'-0"
2"EQ EQ2" 2" 1'-2"
DOOR LEAF
HOLLOW METAL
FRAME PAINT
SCHEDULED DEVICE 1/4" CLEAR TEMPERED GLASS
REMOVABLE METAL STOP
DOUBLE JAMB STUDS
(3) ANCHORS PER JAMB
SEALANT
HOLLOW METAL
FRAME- PAINT
C.L. OF
SCHEDULED
DEVICE
1.03
HOLLOW METAL SIDELIGHT JAMB DETAIL
SCALE: 3"=1'-0"
10"
2"
'-2
DO
OR
A
ND
F
RA
ME
H
EIG
HT
1/4"
WOOD TRIM AT HEAD ONLY:
DRYWALL CASED OPENING
AT JAMB
HEAVY-DUTY BI-FOLD DOOR
TRACK AND PIVOT HARDWARE
CLOSET SIDE
SCHEDULED BASE
SCHEDULED FLOOR FINISH
DOUBLE JAMB STUDS
METAL CORNER BEADS - TYPICAL
2 x 4 FIRE RETARDANT TREATED
CONTINUOUS BLOCKING
1.03
BI-FOLD DOOR HEAD DETAIL
SCALE: 3"=1'-0"
1.03
BI-FOLD DOOR JAMB DETAIL
SCALE: 3"=1'-0"
SE
E
PA
RT
ITI
ON
TY
PE
S
SEE PARTITION TYPES
2x4 FIRE RETARDANT TREATED
WOOD BLOCKING NESTED IN
METAL STUD TRACK
PRIOR TO CONSTRUCTION COMMENCEMENT, A PROPOSED PLAN FOLLOWING INDUSTRY STANDARDS TO RECYCLE CONSTRUCTION AND DEMOLITION WASTE SHALL BE PREPARED. THE CONSTRUCTION WASTE MANAGEMENT PLAN SHALL QUANTIFY MATERIAL DIVERSION GOALS AND MAXIMIZE THE MATERIALS TO BE RECYCLED AND/OR SALVAGED (AT LEAST 50%) FROM CONSTRUCTION, DEMOLITION, AND PACKAGING DEBRIS. WHERE THE SMALL QUANTITY OF MATERIAL, THE EXTRAORDINARILY COMPLEX NATURE OF THE WASTE DISPOSAL METHOD, OR PROHIBITIVE EXPENSE FOR RECYCLING WOULD REPRESENT A GENUINE HARDSHIP, THE GOVERNMENT, UPON WRITTEN REQUEST OF THE LESSOR AND APPROVAL OF THE LEASE CONTRACTING OFFICER MAY PERMIT
ALTERNATIVE MEANS OF DISPOSAL
CARPET RECLAMATION: RECLAMATION OF EXISTING CARPET TO BE DETERMINED WITH POTENTIAL VENDOR.
WHERE CARPET IS REPLACES, SUBMIT CERTIFICATION DOCUMENTATION FROM THE RECLAMATION FACILITY TO THE
LCO (LEASE CONTRACTING OFFICER).
CONSTRUCTION WASTE MANAGEMENT PLAN
NOTE: REFER TO SHEETS A1.02, A1.03, A1.04, AND A1.05, VA
SPECIFIC GENERAL NOTES, WHICH SUPPLEMENT THE NOTES ON
THIS PAGE. VA SPECIFIC NOTES WITH MORE STRINGENT
REQUIREMENTS SUPERCEDE ALL NOTES FOUND IN DRAWINGS.
FE
REVISIONS
ALIGNED
STUDIO, LLC
ARCHITECTURE + DESIGN
MISSOURI CERTIFICATE OF AUTHORITY
No. 2016030702
DRAWN BY:
REVIEWED BY:
13100 MANCHESTER
JOB NO.
DATE:
CONTACT:
314.317.0060
SUITE 225
ST. LOUIS, MO 63131
www.aligned-studio.com
OF
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
FO
R:
DE
PA
RT
ME
NT
O
F
VE
TE
RA
NS
' A
FF
AIR
S
RE
AD
JU
ST
ME
NT
C
OU
NS
EL
IN
G
SE
RV
ICE
S
NO
RT
H
OU
TE
R
TO
W N
AN
D
CO
UN
TR
Y, MI
SSO
UR
I 6
MICKI WEHMEIER
micki@aligned-studio.com
RANDY WINZEN
randy@aligned-studio.com
1720.1
11.01.17
A2.01
FLOOR PLAN
& PARTITION TYPES
RCW
RCW
PARTIAL SECOND FLOOR PLAN
SCALE: 1/8"=1'-0"
FLOOR PLAN GENERAL NOTES
1. ALL SHADED AREAS INDICATE "NO WORK" OR "NOT IN CONTRACT" UNLESS OTHERWISE NOTED ON PLAN.
2. ALL PARTITIONS SHALL BE "P1" UNLESS OTHERWISE NOTED ON PLAN. SEE SEISMIC DETAILS 1, 5 & 9/A3.01
AND PARTITION TYPES, SHEET A2.01.
3. ALL ANGLES SHALL BE 90 DEGREES UNLESS OTHERWISE NOTED ON PLAN.
4. ALL OPENINGS TO BE MINIMUM 3'-0" WIDE CLEAR UNLESS OTHERWISE DIMENSIONED ON PLAN.
5. PROVIDE AND INSTALL FIRE RETARDANT WOOD BLOCKING IN WALL FOR ALL BUILT-IN MILLWORK, TYPICAL.
6. ALL GLAZING SHALL BE TEMPERED. SEE PLAN AND\/OR ELEVATIONS FOR SPECIFIC GLASS WIDTH DIMENSIONS.
ORDER ALL GLASS WITHOUT MANUFACTURERS STAMP AND FREE OF BLEMISHES AND TONG MARKS.
7. GENERAL CONTRACTOR TO COORDINATE ALL HORN STROBE AND/OR FIRE ALARM PULL STATION LOCATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. GC MUST USE BUILDING STANDARD FIRE ALARM DEVICES WHEN FURNISHING ADDITIONAL FIRE ALARM DEVICES AND MUST USE A LANDLORD APPROVED SIMPLEX CONTRACTOR FOR MAKING
CONNECTIONS TO THE FIRE ALARM SYSTEM.
8. GC TO FURNISH AND INSTALL 5 GAL HOT WATER HEATER ABOVE CEILING WITH DRAIN LINE AND OVERFLOW PAN- SEISMICALLY BRACE TO STRUCTURE ABOVE PER MFGR. REQUIREMENTS. (BREAK ROOM 232). SEE M.E.P.
DRAWINGS.
9. PROVIDE AND INSTALL NEW VERTICAL BLINDS AT ALL EXTERIOR WINDOWS. WAND OPERATION ONLY. NO
CORDS WILL BE PERMITTED.
10. PROVIDE 1" RADIUS AT ALL COUNTERTOPS WITH OPEN ENDED CORNERS.
1 ALIGN NEW PARTITION WITH EXISTING CONSTRUCTION OR PARTITIONS ACROSS OPENINGS IN SAME
PLANE WITH NO VISIBLE JOINTS
REPLACE ANY FINISHES DISTURBED BY CONSTRUCTION WITH NEW TO MATCH EXISTING. VERIFY EXTENT
OF WORK IN FIELD.
CENTER NEW PARTITION ON EXISTING WINDOW MULLION- VERIFY EXACT LOCATION IN FIELD.
EXISTING BUILDING COLUMN. REDUCE TO SMALLEST POSSIBLE DIMENSION AN PATCH AS REQUIRED-
PROTECT DURING CONSTRUCTION.
NEW ELECTRIC PANELS AND TRANSFORMER- TO BE SIZED, LOCATED AND COORDINATED BY ELECTRICAL
DESIGN BUILD CONTRACTOR. (NETWORK 231). SEE ENLARGED PLAN 14/3.02.
PROVIDE COLD WATER LINE WITH SHUT OFF VALVE FOR TENANT'S REFRIGERATOR ICEMAKER, AND
COFFEE MAKER (BREAK ROOM 232)- VERIFY EXACT MFGR. REQUIREMENTS.
NEW PLASTIC LAMINATE RECEPTION DESK BY OTHERS.
PLASTIC LAMINATE BASE AND WALL CABINETS WITH PLASTIC LAMINATE COUNTERTOP- SEE INTERIOR
ELEVATIONS ON A4.01.
(5) 15" DEEP MELAMINE ADJUSTABLE SHELVES ON HEAVY DUTY STANDARDS AND BRACKETS- PROVIDE
TREATED WOOD BLOCKING AS REQUIRED. SEE DETAIL 16/5.01
PROVIDE GALV. CORNER BEADS AT NEWLY EXPOSED CORNERS AFTER DEMOLITION.
6'-0" X 4'-0" X 3/4" FIRE RETARDANT PLYWOOD PHONE BOARD. MOUNT AT 72" A.F.F. AND PAINT TO MATCH ADJACENT WALL- VERIFY EXACT LOCATION WITH TENANT AND M.E.P. DRAWINGS (NETWORK
231). SEE ENLARGED PLAN 14/3.02
18" DEEP PAINT GRADE PLYWOOD SHELF MOUNTED AT 68" A.F.F. AND 1 1/2" DIA. METAL CLOTHES
ROD WITH SUPPORT BRACKET AT MID SPAN. SEE DETAIL 19/4.01
25" DEEP PLASTIC LAMINATE COUNTERTOP WITH 2" RADIUS AT OPEN CORNER, MOUNTED AT 42" A.F.F. PROVIDE PERIMETER SUPPORT AT WALLS AND BRACING AT MIDSPAN- SEE DETAIL 15/4.01.
INCREASE DEPTH OF OFFICE AS MUCH AS POSSIBLE BASED ON REDUCTION OF EXISTING COLUMN BUMP
OUT AND MAINTAINING 44" CLEAR AISLE SPACE IN CORRIDOR.
NEW STAINLESS STEEL SURFACE MOUNTED SINK AND ADA COMPLIANT FAUCET WITH GOOSENECK
HANDLES. PROVIDE ALL REQUIRED PLUMBING LINES AND DRAINS, ETC. AND 1/2 HP GARBAGE
DISPOSAL (BADGER #5 OR EQUAL) IN BREAK ROOM 232.
PROVIDE TREATED WOOD BLOCKING IN WALL FOR THE MOUNTING OF ADA COMPLIANT GRAB BARS.
NEW 18" X 7'-0" X 1/4" TEMPERED GLASS SIDELIGHT IN PAINTED HOLLOW METAL FRAME (TYP.)- SEE
INTERIOR ELEVATION ON SHEET A4.01.
4" DIA. FLOOR DRAIN- SEE PLUMBING DESIGN BUILD DRAWINGS FOR EXACT SPECIFICATIONS AND
LOCATIONS.
PROVIDE NEW MINIMUM DRYWALL ENCLOSURE AS REQUIRED AROUND NEW SPRINKLER PIPE- VERIFY EXACT SIZE AND LOCATION WITH FIRE PROTECTION CONTRACTOR AND SPRINKLER CLOSET BELOW.
PROVIDE TRANSLUCENT SECURITY FILM ON OFFICE SIDE OF COMMON CORRIDOR GLAZING.
ALL CORRIDOR WALLS SHALL TERMINATE AT DECK ABOVE. UPGRADE EXISTING CORRIDOR WALLS AS
REQUIRED TO MEET ONE HOUR RATING OR CONSTRUCT NEW CORRIDOR WALLS ACCORDINGLY.
PROVIDE HOT WATER PUMP AT SINKS TO OPERATE DURING BUSINESS HOURS ONLY IN ORDER TO
BRING WATER TEMPERATURE TO VA STANDARDS.
RELOCATED WALL MOUNTED SUPPLEMENTAL HVAC UNIT- VERIFY UNIT CAN HOLD TEMPERTURE
BETWEEN 70 AND 75 DEGREES. VERIFY EXACT LOCATION IN FIELD. SEE ENLARGED PLAN 14/3.02.
ALL DEMISING WALLS SHALL TERMINATE AT DECK ABOVE. VERIFY IF EXISTING DEMISING WALL
COMPLIES AND UPGRADE AS REQUIRED TO MEET ONE HOUR RATING.
PROVIDE NEW FURRED WALL IN FRONT OF EXISTING DEMISING WALL TO PROVIDE SOUND BARRIER
FROM ADJACENT TENANT. SEE PARTITION TYPES ON SHEET A2.01.
FLOOR PLAN KEYED NOTES X
1. ALL DOOR OPERATING DEVICES SHALL BE CAPABLE OF OPERATION WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, TWISTING OF THE WRIST OR TIGHT PINCHING. DOOR KNOBS ARE PROHIBITED.
2. ALL MEANS OF EGRESS DOORS SHALL BE READILY OPENABLE FROM THE SIDE FROM WHICH EGRESS IS TO BE
MADE WITHOUT THE USE OF A KEY, SPECIAL TOOL, KNOWLEDGE OR EFFORT.
3. MEANS OF EGRESS DOORS EQUIPPED WITH MAGNETIC LOCKS, CARD READERS, PUSH BUTTON COMBINATION LOCKS, OR OTHER SPECIAL LOCKS SHALL BE ABLE TO UNLOCK IN ACCORDANCE WITH ALL 7 CONDITIONS LISTED
IN THIS CODE SECTION.
4. PRIMARY ENTRANCE DOOR HARDWARE SHALL BE MADE ACCESSIBLE WHEN ANY PORTION OF THE ACCESSIBLE
ROUTE IS ALTERED.
5. SEE SHEET A1.01, SECTION III, 'DOORS, FRAMES AND HARDWARE'. SEE DOOR TYPES AND HARDWARE GROUPS THIS SHEET. CONTRACTOR TO COORDINATE DOOR UNDERCUTS AS REQUIRED WITH MECHANICAL
CONTRACTOR.
6. COORDINATE KEYING WITH TENANT AND BUILDING MANAGEMENT. PROVIDE BUILDING STANDARD FINISH.
UPGRADE EXISTING HARDWARE AS REQUIRED TO ADA COMPLIANT LEVER STYLE HARDWARE.
7. THE GENERAL CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS PIECES, SILENCERS, SEALS, DOOR STOPS, ETC.
AS REQUIRED FOR A COMPLETE INSTALLATION OF ALL INTERIOR DOORS. ALL DOORSTOPS TO BE FLOOR
MOUNTED AT A 90-DEGREE ANGLE TO THE DOOR OPENING, UNLESS NOTED OTHERWISE.
8. AS A PART OF THIS SCOPE, THE EXTERIOR DOORS TO THE BUILDING SHALL BE UPGRADED AS PER THE
FOLLOWING SECURITY SYSTEM COMPONENTS:
A. PROVIDE AND INSTALL 1200 LB MAGNETIC HOLD OPEN DEVICES
B. PROVIDE AND INSTALL SLIM PUSH TO RELEASE EXIT BUTTONS AT INTERIOR DOORS.
C. PROVIDE AND INSTALL PIR DETECTORS AT CEILING
D. PROVIDE AND INSTALL WEATHERPROOF KEYPADS
E. PROVIDE AND INSTALL REQUIRED POWER SUPPLY
F. PROVIDE AND INSTALL FIRE ALARM RELAY AND WIRING AS PER TECH ELECTRONICS
G. PROVIDE AND INSTALL TIMER PACKAGE FOR CONTROLLED RELEASE OF MAGNETIC HOLD OPEN
DEVICES.
H. PROVIDE AND INSTALL 120 V DEDICATED CIRCUIT TO POWER SUPPLY PANEL
I. PROVIDE AND INSTALL LOW VOLTAGE WIRING TO ALL DEVICES VIA SURFACE MOUNTED WIRE MOLD.
DOOR NOTES XDOOR TYPES XHARDWARE TYPES
EXISTING DOOR AND FRAME TO REMAIN. PATCH AND/OR REPAIR TO NEWER CONDITION AND TO
MATCH BUILDING STANDARD FINISH OR AS SPECIFIED.
NEW 3'-0" X 7'-0" X 1 3/4" SOLID CORE, WOOD VENEER DOOR IN A PAINTED HOLLOW METAL FRAME. DOOR STAINED TO MATCH BUILDING STANDARD. SEE DOOR NOTES ON SHEET A1.01. SEE
FRAME DETAILS 1/1.03 & 5/1.03.
NEW PAIR OF 3'-0" X 7'-0" X 1 3/4" SOLID CORE, WOOD VENEER DOORS IN A PAINTED HOLLOW METAL FRAME. DOOR STAINED TO MATCH BUILDING STANDARD. SEE DOOR NOTES ON SHEET A1.01.
SEE FRAME DETAILS 1/1.03 & 5/1.03.
NEW 3'-0" X 7'-0" X 1 3/4" SOLID CORE, WOOD VENEER ENTRY DOOR WITH A 1'-8" X 7'-0" X 1/4" TEMPERED GLASS SIDELIGHT, BOTH IN A PAINTED HOLLOW METAL FRAME. DOOR STAINED TO MATCH BUILDING STANDARD. SEE DOOR NOTES ON SHEET A1.01. SEE FRAME DETAILS 1/1.03 & 5/1.03.
NEW PAIR OF 2'-0" X 7'-0" X 1 3/4" SOLID CORE, WOOD VENEER BI-FOLD DOORS IN A DRYWALL
CASED OPENING. DOORS STAINED TO MATCH BUILDING STANDARD. SEE DOOR NOTES ON SHEET
A1.01. SEE DETAILS 14/1.03 & 15/1.03.
NEW 3'-6" X 7'-0" X 1 3/4" SOLID CORE, WOOD VENEER DOOR IN A PAINTED HOLLOW METAL FRAME. DOOR STAINED TO MATCH BUILDING STANDARD. SEE DOOR NOTES ON SHEET A1.01. SEE
FRAME DETAILS 1/1.03 & 5/1.03.
EXISTING HARDWARE TO REMAIN. MAKE SURE IT'S IN GOOD WORKING ORDER AND UPGRADE TO BE
ADA ACCESSIBLE AS REQUIRED.
NEW LEVER STYLE OFFICE LOCKSET WITH 1 1/2 PAIR BUILDING STANDARD BUTT HINGES, AND DOME
TYPE FLOOR STOP.
NEW LEVER STYLE PASSAGE SET WITH 1 1/2 PAIR BUILDING STANDARD BUTT HINGES AND DOME STYLE
FLOOR STOP.
NEW LEVER STYLE STOREROOM LOCKSET WITH 1 1/2 PAIR BUILDING STANDARD BUTT HINGES, DOOR
CLOSER AND DOME STYLE FLOOR STOP.
NEW LEVER STYLE PRIVACY LOCKSET, 1 1/2 PAIR BUTT HINGES AND DOME STYLE FLOOR STOP.
NEW LEVER STYLE DUMMY HANDLES ON CORRIDOR SIDE (BLANK ON CLOSET SIDE), 3 PAIR BUTT HINGES, DOME STYLE FLOOR STOPS AND HEAVY DUTY ROLLER CATCHES ON TOP OF EACH LEAF.
NEW LEVER STYLE KEYED ENTRY LOCKSET, 1 1/2 PAIR BUTT HINGES, DOOR CLOSER AND DOME TYPE
FLOOR STOP- DOOR TO BE OPERABLE FROM EGRESS SIDE AT ALL TIMES.
BI-FOLD DOOR MANUFACTURER HARDWARE, TRACKS AND ROLLERS- ALL HARDWARE SHALL BE ADA
COMPLAINT.
NOTE: COORDINATE KEYING WITH TENANT AND BUILDING MANAGEMENT. PROVIDE BUILDING
STANDARD FINISH.
NOTE: UPGRADE EXISTING HARDWARE AS REQUIRED TO ADA COMPLIANT LEVER STYLE HARDWARE.
A
B
NOTES:
SEE SHEET A1.01, SECTION III, 'DOORS, FRAMES AND HARDWARE'. CONTRACTOR TO COORDINATE DOOR UNDERCUTS AS
REQUIRED WITH MECHANICAL CONTRACTOR.
C
4D
E
6'-8" 13'-3"+/-
7'- 4"
2'- 1"
8'- 0"
1'- 0"
7'-
1/ 2"
4'-2"2'-10"+/-
1'-
1/ 4"
5'-0"
1'-0
1'-6
1'-0
1'-6
1'-0
1'-6
1'-0
1'-6
1'-0
1'-6
1'-0
1'-6
3'-4"
8'-1 3/
4"
1'-6
1'-0
1'-6
1'-0
1'-6" 1'-0"
1'-6" 1'-0"
1'-6"
1'-0"
1'-6
1'-0
1'-6
1'-0
1'-6"
1'-0"
1'-6"
1'-0"
1'-0"
1'-6"
1'-0" 1'-6"
1'-6"
1'-0"
1'-6
1'-0
1'-6
1'-0
2'- 6"
1'-8"
(1'-6" MIN.)
4.01
5'-0"
15'-8"
15'-8"
8'-0 1/4"+/-
9'-8 1/
4"
19' -8 1/4
5'-0
9'-8 1/
4"
9'-8 1/
4"
5'-0
3'-8"(MIN.)
11'-11"+/- 5'-0"
15'-0"+/-
EQ
EQ
5'-0"
13'-5"+/-
EQ
EQ
5'-0
5'-0
1'-4
4'-4 1/
2"+
9'-0 1/
4"+
2'-11"
2'-3"
1'-10"
1'-2 1/2"+/-
7'-8"
10'-8 5/8"
5'-0" 1'-8"
2'-3
5/8"
4 4
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
SES DIRECTOR
OFFICE
CONFERENCE
WORK RM.
TRAINING/
MULTIPURPOSE
ADA
MEN
ADA
WOMEN
OFFICE
OFFICE
OFFICE
NETWORK
OFFICE
BREAK
ROOM
STOR.
WAITING
COATS
CORRIDOR
CORR.
CORR.
CORR.
CORR.
CORR.
RECEPTION
BUILDING
CORRIDOR
STOR.
CORR.
CORR.
F
A
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
F
B
B
B
B
B
F
F
C
D
2.01 TYP.
2.01 TYP.
4.0
4.0
4.0
E
17 17
F
SCHEDULED BASE
SCHEDULED FLOOR FINISH
3 5/8" METAL STUDS, 25 GA. AT 16" O.C.
5/8" GYPSUM BOARD EACH SIDE
4 7/8"
USG 200-B METAL GYPSUM BOARD TRIM
SCHEDULED CEILING
8'- 6"
(V
ER
IFY
IN
F
IEL
D)
3 1/2" SOUND BATT INSULATION
SOUND BATT INSULATION TO 4'-0"
EACH SIDE OF PARTITION
WALL BASE
SCHEDULED FLOOR FINISH
3 5/8" METAL STUDS, (25 GA.) AT 16" O.C.
5/8" GYPSUM BOARD EACH SIDE
4 7/8"
EXISTING DECK- FIELD VERIFY
8'- 6"
6"
NEW DRYWALL CEILING
PARTITION TYPE
SCALE: 1 1/2"=1'-0"
(SE
E
RE
FL
EC
TE
D
CE
ILI
NG
P
LA
N)
3 1/2" SOUND ATTENUATION FRICTION FIT BATTS
P1
NEW OR EXISTING
ACOUSTIC CEILING
PARTITION TYPE
SCALE: 1 1/2"=1'-0"P2
3 1/2" SOUND ATTENUATION
BATTS TO EXTEND 4'-0" ON
EACH SIDE OF PARTITION
SCHEDULED BASE
SCHEDULED FLOOR FINISH
3 5/8" METAL STUDS, 25 GA. AT 16" O.C.
5/8" DRYWALL EACH SIDE
1'-0"
EXISTING DECK - FIELD VERIFY
8'- 6"
(F
IEL
D
VE
RIF
Y)
3 1/2" SOUND ATTENUATION FRICTION FIT BATTS
2 1/2" METAL STUDS AT 48"
O.C. VERTICALLY EACH STUD
DRYWALL CEILING
6"
PARTITION TYPE
SCALE: 1 1/2"=1'-0"P3 PLUMBING CHASE WALL
3 1/2" SOUND ATTENUATION
BATTS TO EXTEND 4'-0" ON
EACH SIDE OF PARTITION
NOTE: PARTITIONS TO TERMINATE AT 9'-0"
A.F.F. AND KICK BACK TO STRUCTURE ABOVE
PER SEISMIC BRACING DETAIL 5/A3.02
RESTROOM SIDE
PARTITION TYPE
SCALE: 1 1/2"=1'-0"P4
SCHEDULED BASE
SCHEDULED FLOOR FINISH
2 1/2" METAL STUDS, 25
GA. AT 16" O.C.
5/8" TYPE DRYWALL
3 1/8"
8'- 6"
6"
SCHEDULED CEILING
2 1/2" R-13 INSULATION WITH
VAPOR BARRIER
EXISTING PARTITION OR COLUMN
1/2" AIR SPACE
NOTE: PARTITIONS TO TERMINATE AT 9'-0"
A.F.F. AND KICK BACK TO STRUCTURE ABOVE
PER SEISMIC BRACING DETAIL 5/A3.02
NOTE: PARTITIONS TO TERMINATE AT 9'-0"
A.F.F. AND KICK BACK TO STRUCTURE ABOVE
PER SEISMIC BRACING DETAIL 5/A3.02
24" MAX.
(JOG TO CLOSEST MULLION)
1/ 2"
N.T .S
2.01
DETAIL AT PARTITION AT MULLION
SCALE: 3"=1'-0"
EXISTING CURTAIN WALL SYSTEM.
DO NOT FASTEN INTO OR THRU
EXISTING MULLION
SEALANT- COLOR TO MATCH MULLION
DOUBLE SIDED FOAM TAPE
U.S.G. 200A FILL BEAD PAINT
OUTSIDE EDGE TO MATCH MULLION
PERIMETER BASE HEATER (WHERE OCCURS).
FILL VOID WITH FIBERGLASS SOUND BATTING.
SCRIBE GYPSUM BOARD TO SILL
AND HEATER BELOW.
HOLD TIGHT TO EXTERIOR WALL AS
POSSIBLE (12" TYP.) ALLOW FOR
BASEBOARD HEATING AND CIRCULATION
C/L OF MULLION = C/L OF PARTITION
UNLESS OTHERWISE NOTED ON FLOOR PLAN
SILL BELOW
1'-0" 1'-6" 1'-0"1'-6"
TYP.
1'-4" 4'-3"
1'-1
ENVIRONMENTALLY PREFERABLE PRODUCT REQUIREMENTS
A. THE GC MUST PROVIDE ENVIRONMENTALLY PREFERABLE PRODUCTS AS DETAILED THROUGHOUT THE SUITE. (I.E.: PLUMBING FIXTURES,WATER
CONSERVATION)
B. WHEN THE DRAWINGS DO NOT CONTAIN SPECIFIC REQUIREMENTS FOR ENVIRONMENTALLY PREFERABLE PRODUCTS, THE GC MUST PROVIDE PRODUCTS MEETING ONE OF THE BELOW ENVIRONMENTALLY PREFERABLE CRITERIA WHEN SUCH PRODUCTS ARE AVAILABLE. THE GC CAN CONSULT THE GREEN PROCUREMENT COMPILATION AT WWW.SFTOOL.GOV/GRENPROCUREMMENT TO DETERMINE WHETHER ANY OF THESE CRITERIA ARE APPLICABLE FOR A
PRODUCT CATEGORY.
1. BIO-PREFERRED PRODUCTS
2. ENERGY STAR PRODUCTS
3. EPA COMPREHENSIVE PROCUREMENT GUIDELINE DESIGNATED (RECYCLED CONTENT) PRODUCTS
4. EPA SAFER CHOICE LISTED PRODUCTS
5. FEMP-DESIGNATED ENERGY EFFICIENT PRODUCTS
6. SNAP (SIGNIFICANT NEW ALTERNATIVE POLICY) SUBSTANCES
7. WATER SENSE OR OTHER WATER EFFICIENT PRODUCTS.
C. THE GC, IF UNABLE TO COMPLY WITH THE ENVIRONMENTALLY PREFERABLE PRODUCT REQUIREMENTS ABOVE, MUST SUBMIT A WAIVER REQUEST FOR EACH MATERIAL WITHIN THE TI PRICING SUBMITTAL. THE WAIVER REQUEST SHALL BE BASED ON THE FOLLOWING EXCEPTIONS:
1. PRODUCT CANNOT BE ACQUIRED COMPETITIVELY WITHIN A REASONABLE PERFORMANCE SCHEDULE.
2. PRODUCT CANNOT BE ACQUIRED THAT MEETS REASONABLE PERFORMANCE REQUIREMENTS.
3. PRODUCT CANNOT BE ACQUIRED AT A REASONABLE PRICE.
4. AN EXCEPTION IS PROVIDED BY STATUTE.
THE PRICE SHALL BE DEEMED UNREASONABLE WHEN THE TOTAL LIFE CYCLE COSTS ARE SIGNIFICANTLY HIGHER FOR THE SUSTAINABLE PRODUCT VERSUS THE NON- SUSTAINABLE PRODUCT. LIFE CYCLE COSTS ARE DETERMINED BY COMBINING THE INITIAL COSTS OF A PRODUCT WITH ANY ADDITIONAL COSTS
OR REVENUES GENERATED FROM THAT PRODUCT DURING ITS ENTIRE LIFE.
NOTE: REFER TO SHEETS A1.02, A1.03, A1.04, AND A1.05, VA
SPECIFIC GENERAL NOTES, WHICH SUPPLEMENT THE NOTES ON
THIS PAGE. VA SPECIFIC NOTES WITH MORE STRINGENT
REQUIREMENTS SUPERCEDE ALL NOTES FOUND IN DRAWINGS.
P4
3 5/8"
NOTE: ANY NEW OR EXISTING PARTITION THAT HAS A CONTINUOUS UNINTERRUPTED
RUN OF OVER 12'-0" IN LENGTH IS REQUIRED TO HAVE THE TOP OF THE PARTITION
SEISMICALLY BRACED TO THE STRUCTURE ABOVE WITH METAL STUD KICKERS PER THE
DETAILS PROVIDED ON THE DRAWINGS. ANY WALLS WITH INTERSECTING
PERPENDICULAR PARTITIONS AT INTERVALS OF LESS THAT 12'-0" CAN ELIMINATE THE
KICKERS AND ARE NOT REQUIRED TO BE SEISMICALLY BRACED.
REVISIONS
ALIGNED
STUDIO, LLC
ARCHITECTURE + DESIGN
MISSOURI CERTIFICATE OF AUTHORITY
No. 2016030702
DRAWN BY:
REVIEWED BY:
13100 MANCHESTER
JOB NO.
DATE:
CONTACT:
314.317.0060
SUITE 225
ST. LOUIS, MO 63131
www.aligned-studio.com
OF
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
FO
R:
DE
PA
RT
ME
NT
O
F
VE
TE
RA
NS
' A
FF
AIR
S
RE
AD
JU
ST
ME
NT
C
OU
NS
EL
IN
G
SE
RV
ICE
S
NO
RT
H
OU
TE
R
TO
W N
AN
D
CO
UN
TR
Y, MI
SSO
UR
I 6
MICKI WEHMEIER
micki@aligned-studio.com
RANDY WINZEN
randy@aligned-studio.com
1720.1
11.01.17
A2.02
FINISH PLAN &
FINISH SPECIFICATIONS
RCW
RCW
PARTIAL SECOND FLOOR FINISH PLAN
SCALE: 1/8"=1'-0"
BASE:
DOORS:
FRAMES:
WALLS:
VB-1
BUILDING STANDARD
P-4 P-1
C-1
CARPET
STYLE:
MFG:
INSTALL:
COLOR:
P-1 MFG:
PLASTIC LAMINATE
CONTACT:
P-2 MFG:
COLOR/NO.:
FINISH:
COLOR/NO.:
PATCRAFT
10291 EXPERIENCE
00425 SOLUTION
ASHLAR
TODD HEILMAN, 314.640.6521
VCT-1
VINYL COMPOSITION TILE
STYLE:
SIZE:
MFG:
CONTACT:
COLOR:
ARMSTRONG
STANDARD EXCELON
PEAT 59240
12" X 12"
NANCY WASER, 636-448-9409
PL-1
WK
TOPS
STYLE:
FINISH:
MFG:
CONTACT:
COLOR NO.:
FORMICA
BLACKENED STEEL
8918-58
MATTE
RICHELE SMITH 816.337.6235
PL-2
WK
FACE
STYLE:
FINISH:
MFG:
CONTACT:
COLOR NO.:
FORMICA
GRAPHITE
837-58
MATTE
RICHELE SMITH, 816.377.6235
P-3 MFG:
COLOR/NO.:
FINISH:
FINISH:
FINISH SPECIFICATIONS
FINISH SYSTEMS
PPG
PPG-1007-4 HOT STONE
EGGSHELL
SHERWIN WILLIAMS
SW2820 DOWNING EARTH
EGGSHELL
SHERWIN WILLIAMS
SW6250 GRANITE PEAK
EGGSHELL
BASE:
DOORS:
FRAMES:
WALLS:
LV-1
LUXURY VINYL PLANK
STYLE:
SIZE:
MFG:
CONTACT:
COLOR:
PATCRAFT
TIMBER GROVE II 1420V
00572 HEMLOCK
5.96" X 48"
TODD HEILMAN, 314.640.6521
VB-1
BUILDING STANDARD
P-4 P-2
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
SES DIRECTOR
OFFICE
CONFERENCE
WORK RM.
TOILET
OFFICE
OFFICE
OFFICE
NETWORK
OFFICE
BREAK
ROOM
STOR.
WAITING
COATS
CORRIDOR
CORR.
CORR.
CORR.
CORR.
CORR.
RECEPTION
BUILDING
CORRIDOR
STOR.
CORR.
CORR.
OFFICE
OFFICE
TRAINING/
MULTIPURPOSE
EXISTING CONCRETE SLAB
(SHOWN SHADED)
VINYL FLOORING
CARPET
VINYL TRANSITION CAP TO MATCH TILE
2.02
FLOORING TRANSITION
FULL SCALE
FINISH PLAN GENERAL NOTES FINISH PLAN KEYED NOTES
11. PROVIDE AND INSTALL NEW CARPET, VINYL BASE AND PAINT THROUGHOUT SUITE UNLESS OTHERWISE NOTED.
2. ALL HARDWARE TO MATCH BUILDING STANDARD FINISH, UNLESS OTHERWISE NOTED.
3. ALL MILLWORK TO BE SHOP FINISHED. ALL PAINTED MILLWORK TO BE SHOP SPRAYED PAINTED LOW GLOSS LACQUER FINISH.
4. FLOOR TRANSITIONS SHALL OCCUR AT THE CENTERLINE OF DOOR, UNLESS OTHERWISE NOTED.
5. PROVIDE AND CONTINUE SCHEDULED FLOORING FROM PARTITION TO PARTITION AND UNDER MILLWORK UNLESS OTHERWISE NOTED.
6. PROVIDE HIGH GLOSS WAX FINISH ON ALL SCHEDULED VCT FLOORING.
7. DO NOT PROVIDE SCHEDULED RUBBER/VINYL BASE ON MILLWORK PLASTIC LAMINATE TOE-KICK TYPICAL. REFER TO MILLWORK
SECTIONS/DETAILS.
8. SEAM SEALER REQUIRED AT ALL BROADLOOM CARPET SEAMS AND EXPOSED (UNBOUND) EDGES IN ACCORDANCE WITH THE CRI INSTALLATION
INSTRUCTIONS.
9. PROVIDE 4" HIGH COVED BASE AT ALL CARPETED AREAS AND HARDSURFACE FLOORING AREAS UNLESS OTHERWISE NOTED ON PLANS.
10. FINISH SYSTEMS DESCRIBE THE FINISH SPECIFICATION FOR THE VERTICAL SURFACE AT ALL ITEMS PLACED ON A PARTITION. IF DISCREPANCY OCCURS, CONTACT THE ARCHITECT FOR CLARIFICATION PRIOR TO STARTING WORK WITHIN THE SUBJECT AREA.
EXISTING FINISHES TO REMAIN. MATCH FINISHES (BASE, PAINT, FLOORING) AT REWORKED ENTRY TO RECEPTION
AND ALONG DEMISE LOCATION WHERE NEW DRYWALL HAS BEEN INSTALLED.
PROVIDE AND INSTALL ACROVYN CORNER GUARD. SSM SERIES, #SSM-20, PARTIAL HEIGHT COLOR TO MATCH ADJACENT PAINT. GC TO PROVIDE SAMPLES. CORNER GUARD SHALL EXTEND FROM TOP OF BASE TO 48" AFF.
VERIFY IF CORNER GUARD SPECIFIED IN KEYED NOTE #2 AND BE BENT TO ACCOMMODATE 135 DEGREE
ANGLE.
PROVIDE AND INSTALL ACROVYN BG30N CHAIR RAIL AT 30" AFF O.C. (COORDINATE EXACT HEIGHT WITH TENANT'S FURNITURE VENDOR) AT ALL DRYWALL PARTITIONS OF CONFERENCE ROOM CAN MULTI-PURPOSE ROOM.
COLOR TO MATCH ADJACENT PAINT. GC TO PROVIDE SAMPLES.
PROVIDE AND INSTALL CARPET INSET OF C-1 BENEATH RECEPTION DESK. COORDINATE EXACT LOCATION AND SIZE OF DESK WITH TENANT'S FURNITURE VENDOR. REAR EDGE OF INSERT SHALL ALIGN WITH FRONT PARTITION
OF COAT CLOSET.
X
VB-1
VINYL BASE
STYLE:
SIZE:
MFG:
CONTACT:
COLOR:
JOHNSONITE
COVED STANDARD BASE
29 MOONROCK WG
4" MICHELLE LEBBING, 314.739.2273 x1013
PAINT
C 1
C 1
C 1
C 1
C 1
C 1
C 1
C 1
C 1
C 1
C 1
C 1
C 1
C 1
C 1
C 1
C 1
C 1
C 1
VP 1
VP 1
X
VP 1
C 1
C 1
C 1
P-4 MFG:
COLOR/NO.:
FINISH:
PPG
PPG-1007-4 HOT STONE
ENAMEL
BASE:
DOORS:
FRAMES:
WALLS:
VB-1
BUILDING STANDARD
P-4 P-3
VP 1
TOILET
VP 1
VCT 1
VP 1
VP 1
VP 1
VP 1
VP 1
VP 1
VP 1
VP 1
VP 1
VP 1
2.02
2.0214
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
2.02
INDOOR ENVIRONMENTAL QUALITY NOTES
ALL ADHESIVES AND SEALANTS APPLIED IN THE PREMISES SHALL COMPLY WITH THE REQUIREMENTS OF LEED CREDIT
IEQ4.1
INTERIOR PAINTS AND COATINGS APPLIED IN THE PREMISES MUST MEET THE LIMITATIONS AND RESTRICTIONS CONCERNING
CHEMICAL COMPONENTS ST BY LEED CREDIT IEQ4.2. VA SPECIFICS AS FOLLOWS:
1. TOP COAT PAINTS: GREEN SEAL STANDARD GS-11, PAINTS FIRST EDITION MAY 20,1993
2. ALL OTHER ARCHITECTURAL COATINGS, PRIMERS, AND UNDERCOATS: SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT
(SCAQMD) RULE 1113,
ARCHITECTURAL COATINGS EFFECTIVE JANUARY 1, 2004.
3. ARCHITECTURAL PAINTS, COATINGS, AND PRIMERS APPLIED TO INTERIOR WALLS AND CEILINGS:
A. FLATS: 50 GRAMS PER LITER (G/L)
B. NON-FLATS: 150 G/L
4. ANTI CORROSIVE AND ANTI-RUST PAINTS APPLIED TO INTERIOR FERROUS METAL SUBSTRATES: 250 G/L.
5. CLEAR WOOD FINISHES
A. VARNISH: 350 G/L
B. LACQUER: 550 G/L
6. FLOOR COATINGS: 100G/L
7. SEALERS:
A. WATERPROOFING SEALERS: 250 G/L
B. SANDING SEALERS: 275 G/L
C. ALL OTHER SEALERS: 200 G/L
8. SHELLACS:
A. CLEAR: 730 G/L
B. PIGMENTED: 550 G/L
9. STAINS: 250G/L
ALL FLOORING MATERIAL MUST MEET THE STANDARDS CONTAINED IN LEED CREDIT IEQ4.3, INCLUDING CARPET, CARPET ADHESIVES, AND HARD SURFACE FLOORING. CARPET MUST HAVE CERTIFICATION AS A GOLD LEVEL MIN. FOR THE ANSI/NSF 140 2007E SUSTAINABLE CARPET ASSESSMENT STANDARD. CARPET MANUFACTURER MUST SUPPLY CERTIFICATE. RECYCLED CONTENT
MUST BE AT
LEAST 10% POST-CONSUMER RECOVERED CONTENT. CARPET AND FLOOR ADHESIVE (FOR GLUE-DOWN INSTALLATION MUST
MEET THE
GREEN LABEL PLUS (GLP) AND FLOOR ADHESIVE(FOR DIRECT GLUE-DOWN) REQUIREMENTS OF THE CARPET AND RUG
INSTITUTE (CRI)
GLP NUMBER MUST BE PROVIDED. ADHESIVES MUST MEET VOC CONTENT STANDARDS PER SOUTH COAST AIR QUALITY
MANAGEMENT
DISTRICT RULE #1168.
COMPOSITE WOOD AND AGRIFIBER PRODUCTS, INCLUDING CORE MATERIALS, MUST CONTAIN NO ADDED
UREA-FORMALDEHYDE
RESINS PER LEED CREDIT IEQ4.4
2.02
2.02
2.02
2.02
2.02
2.02
P-5 MFG:
COLOR/NO.:
FINISH:
SHERWIN WILLIAMS
SW7007 CEILING BRIGHT WHITE
FLAT
C 1
VCT 1
BASE:
DOORS:
FRAMES:
WALLS:
CTB-1
BUILDING STANDARD
P-4 P-1
BASE:
DOORS:
FRAMES:
WALLS:
CTB-1
BUILDING STANDARD
P-4
CT-1 TO 48" AFF; P-1 ABOVE
PROVIDE BULLNOSE TOP .
CT-1
CERAMIC WALL TILE
CTB-1
CERAMIC TILE BASE
STYLE:
FINISH:
MFG:
CONTACT:
COLOR:
AMERICAN OLEAN
PROFILES
DESIGNER WHITE
3" X 6"
MATTE
SUSAN MILLEVILLE, 618.444.6949
SIZE:
STYLE:
FINISH/PROFILE:
MFG:
CONTACT:
COLOR:
AMERICAN OLEAN
PROFILES
DESIGNER WHITE
3" X 6"
MATTE, COVED
SUSAN MILLEVILLE, 618.444.6949
SIZE:
2.02
NOTE: REFER TO SHEETS A1.02, A1.03, A1.04, AND A1.05, VA
SPECIFIC GENERAL NOTES, WHICH SUPPLEMENT THE NOTES ON
THIS PAGE. VA SPECIFIC NOTES WITH MORE STRINGENT
S
S
S
S
FE
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
RRR
R R R
RRR
R
N
N
R
R
R
R
RRR
R
R
R
RR
R
R
R
R
R
R
R
R
R
R
RR
R
R
R
R
R
R
R
R
R
R
R
R
R R
R
R
R
R
R
R
N
N
N
N
N
N
N
N
N
N
N
N
N
N
R
N
N N
N
N S
S
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N N
N
N
N
N
N
N
N
N
N N
N
N
N SN3 3
S
N3
N
N
S
N
N
REVISIONS
ALIGNED
STUDIO, LLC
ARCHITECTURE + DESIGN
MISSOURI CERTIFICATE OF AUTHORITY
No. 2016030702
DRAWN BY:
REVIEWED BY:
13100 MANCHESTER
JOB NO.
DATE:
CONTACT:
314.317.0060
SUITE 225
ST. LOUIS, MO 63131
www.aligned-studio.com
OF
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
FO
R:
DE
PA
RT
ME
NT
O
F
VE
TE
RA
NS
' A
FF
AIR
S
RE
AD
JU
ST
ME
NT
C
OU
NS
EL
IN
G
SE
RV
ICE
S
NO
RT
H
OU
TE
R
TO
W N
AN
D
CO
UN
TR
Y, MI
SSO
UR
I 6
MICKI WEHMEIER
micki@aligned-studio.com
RANDY WINZEN
randy@aligned-studio.com
1720.1
11.01.17
A3.01
REFLECTED CEILING
PLAN & SEISMIC
BRACING DETAILS
RCW
RCW
PARTIAL SECOND FLOOR REFLECTED CEILING PLAN
SCALE: 1/8"=1'-0"
REFLECTED CEILING PLAN GENERAL NOTES
1. ALL SHADED AREAS INDICATE "NO WORK" OR "NOT IN CONTRACT" UNLESS OTHERWISE NOTED ON PLAN.
2. PROVIDE NEW 2 X 4 ARMSTRONG CIRRUS SECOND LOOK 15/16" BEVELED TEGULAR CEILING TILE (#513; NRC 0.65) IN EXISTING GRID AT 8'-6" A.F.F. UNLESS OTHERWISE NOTED ON PLAN- REPAIR GRIDS AS REQUIRED. PROVIDE DEDUCT ALTERNATE PRICE TO KEEP EXISTING TILES TO REMAIN. SEE SEISMIC BRACING DETAILS ON SHEET A3.01.
3. PROVIDE NEW DRYWALL CEILINGS AT 8'-6" IN NEW MEN'S RESTROOMS 239 AND WOMEN'S RESTROOM 240.
4. ALL SPRINKLER AND FIRE PROTECTION WORK WILL BE DESIGN BUILD.
5. PROVIDE NEW OR RELOCATE EXISTING EXIT LIGHTS TO MATCH BUILDING STANDARD AND AS REQUIRED BY CODE.
6. ALL RECESSED INCANDESCENT DOWNLIGHTS SHOWN ARE RELOCATED FROM DEMOLITION. RELAMP WITH LED OR
REPLACE AS REQUIRED.
7. INCLUDE ALL NEW SPRINKLER WORK IN CONTRACT. ADD SPRINKLER HEADS AS REQUIRED WITH LIGHTING LAYOUT SHOWN AND TO MEET LOCAL CODES. SPRINKLER HEADS TO BE APPROVED BY BUILDING OWNER/MANAGEMENT.
SPRINKLER HEADS ARE NOT SHOWN ON THIS PLAN.
8. ALL SWITCHES AND DIMMERS (WHERE OCCURS) AT SAME LOCATION SHALL MATCH IN SAME STYLE AND FINISH. DEVICE COLOR SHALL MATCH WHITE. REPLACE ALL DEVICES AND COVER PLATES AS REQUIRED TO MATCH WHITE. LOCATE NEW SWITCHES 6" TO CENTERLINE FROM DOOR JAMB UNLESS OTHERWISE NOTED, OR IF A SIDELIGHT IS SCHEDULED.
7. MECHANICAL ENGINEER TO ENSURE THAT THE SUITE'S MECHANICAL SYSTEM IS DESIGNED AND INSTALLED TO MAINTAIN THERMAL ENVIRONMENTAL CONDITIONS FOR HUMAN OCCUPANCY AS ESTABLISHED BY ASHRAE STANDARD 55-2004.
8. MECHANICAL SYSTEM IS TO BE BALANCED BY A THIRD PARTY LANDLORD-APPROVED AIR BALANCING CONTRACTOR.
9. TIE LIFE SAFETY LIGHTING AND ALARMS INTO BUILDING STANDARD SECURITY SYSTEM.
10. ALL SPRINKLER AND FIRE PROTECTION WORK WILL BE DESIGN BUILD.
11. DIMENSIONS SHOWN ON PLAN FOR 2 X 2 CORRIDOR LIGHTS ARE FOR LIGHTS NOT TOUCHING THREE GRID LINES
ONLY. ALL OTHER LIGHTS SHALL JUST BE PLACED AS THEY ARE LOCATED.
12. RETROFIT ALL EXISTING FLUORESCENT LIGHT FIXTURES WITH T8 ECOLOGIC BULBS. ALL ROOMS EXCEPT WAITING AND RECEPTION SHALL HAVE OCCUPANCY SENSORS. PROVIDE ALTERNATE PRICING FOR NEW LED FIXTURES (LITHONIA
AVANTE AV2 SERIES) THROUGHOUT.
LIGHT FIXTURE SCHEDULE
1 PROVIDE 5/8" DRYWALL CEILINGS IN NEW RESTROOMS AT 8'-6" A.F.F. PAINT DRYWALL CEILING P-5.
WALL SCONCE, DOWN LIGHT(S) AND EXHAUST FAN TO SHALL ALL BE OPERATED BY ONE SWITCH IF POSSIBLE.
PROVIDE NEW CEILING GRID IN THE HATCHED AREA TO MATCH EXISTING IN STYLE, COLOR AND HEIGHT A.F.F.
PROVIDE EXHAUST FAN, 100 CFM (MIN.)- VENT DIRECTLY TO EXTERIOR. EXHAUSTING TO PLENUM IS STRICTLY
PROHIBITED.
PROVIDE GENERAL CORRIDOR SWITCHING IN THIS AREA. ELECTRICAL DESIGN BUILD CONTRACTOR TO
DETERMINE ZONES AND NUMBER OF SWITCHES.
CEILING PLAN KEYED NOTES X
211 234
EARTHQUAKE CLIPS SHALL SECURELY ATTACH THE TROFFER TO
A GRID CEILING. INSTALLS WITH ONE SCREW PER CLIP INTO
PRE-PUNCHED HOLES. CLIPS SHALL MEET NATIONAL
ELECTRICAL CODE AND EARTHQUAKE REQUIREMENTS.
OR
SECURE LIGHT FIXTURES TO GRID CEILING BY MEANS OF
SELF-TAPPING SCREWS AT ALL CORNERS OF FIXTURE.
3.01
SEISMIC BRACING DETAIL
NOT TO SCALE
4'-0"
4'-0"
45 45
SUSPENDED CEILINGS EXCEEDING 1,000 SQUARE FEET IN AREA REQUIRE FOUR NO. 12 GAUGE SPLAY WIRES AND A RIGID VERTICAL COMPRESSION STRUT EVERY 12 FEET ON CENTER STARTING A MAXIMUM OF 6 FEET FROM EACH WALL. THE SPLAY WIRES SHALL BE SECURED TO THE MAIN RUNNER WITHIN 2 INCHES OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING
45 DEGREES FROM THE PLANE OF THE CEILING.
HEAVY DUTY T-BAR CEILING GRID
SUSPENSION SYSTEMLIGHT FIXTURE MUST BE POSITIVELY
ATTACHED TO THE CEILING GRID WITH AN
ATTACHMENT CAPABLE OF CARRYING 100%
OF THE WEIGHT OF THE LIGHT FIXTURE
LIGHT FIXTURES WEIGHING UP TO 56 LBS
REQUIRE TWO VERTICAL SUPPORT WIRES,
THESE WIRES MAY BE SLACK. LIGHT
FIXTURES WEIGHING MORE THAN 56 LBS
SHALL REQUIRE INDEPENDENT SUPPORT
FROM THE SHELL BUILDING STRUCTURE
ABOVE THE CEILING
45 DEGREE 12 GA WIRE BRACING IN PLANE OF MAIN RUNNER,
ALL WIRES ATTACHED TO MAIN RUNNER (4 DIRECTIONS)
SUPPORT WIRES ON THE MAIN AND CROSS RUNNERS A
MAXIMUM DISTANCE OF 8" FROM WALL 4' ON CENTER
SPACING ALONG THE MAIN RUNNER
NOTE:
DETAIL TO OCCUR AT 12'-0" O.C. IN BOTH
DIRECTIONS AND SHOULD OCCUR AT NOT
LESS THAN 4'-0" FROM A SURROUNDING
WALL PER ATSM E580
12 GA. VERTICAL HANGER
WIRE 12'-0" O.C. EACH
DIRECTION, TYP.
MAIN RUNNER
3.01
SEISMIC BRACING DETAIL
NOT TO SCALE
NOTE:
SPRINKLER HEADS AND OTHER PENETRATIONS OF THE SUSPENDED CEILING
SHALL HAVE A 2" OVERSIZE RING, SLEEVE, OR ADAPTOR THROUGH THE CEILING
TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL DIRECTIONS.
CHAIN OR CABLE
12 GA. SUSPENSION WIRE
(TYPICAL) SECURED TO
STRUCTURE
RECESSED LIGHT
FIXTURE
2'X4' ALTERNATE 2'X4' 2'X2'
(FOR UNBRACED
SUSPENSION GRID ONLY)
3.01
SEISMIC BRACING DETAIL
SCALE: 1 1/2"=1'-0"
NOTE: USE THIS DETAIL FOR ALL "NEW" OR "RELOCATED"
LIGHT FIXTURES INSTALLED IN AN EXISTING CEILING GRID
THAT IS NOT SEISMICALLY BRACED. IF EXISTING CEILING GRID
IS SEISMICALLY BRACED, DISREGARD THIS DETAIL.
USE IF ALTERNATE FOR NEW
CEILING GRID IS ACCEPTED
2'-1" 4'-3" 4'-3" 3'-3 1/2"
3'- 6"
3'- 0"
4'-9" 4'-9"
1'-6"
4'- 0"
2'-6
2'-6
TYP
TYP
2'-6"
2'-6"TYP.
TYP.
2'-6
2'-6
TYP
TYP
2'-6" 2'-6"
TYP.
TYP.
2'-6"
2'-6"
TYP.
TYP.
INDOOR ENVIRONMENTAL QUALITY NOTES
MECHANICAL VENTILATION SYSTEMS INSTALLED IN THE SPACE AS A FUNCTION OF THE TENANT FIT-OUT SHALL BE COMPATIBLE WITH THE BUILDING'S BASE SYSTEMS AND MEET OR EXCEED THE MINIMUM REQUIREMENTS OF ASHRAE 62.1-2007
TENANT SHALL ADOPT AN INDOOR AIR QUALITY MANAGEMENT PLAN FOR EXECUTION DURING THE CONSTRUCTION PHASE OF THE
TENANT TIT-OUT THAT COMPLIES WITH LEED CREDIT IEQ3.1
THE CORE AND SHELL INDOOR CONDITIONS COMPLY WITH THE ASHRAE 55-2004, THE STANDARD FOR INDOOR TEMPERATURE AND HUMIDITY CONDITIONS. THE BASE BUILDING HVAC SYSTEMS ARE DESIGNED AND INSTALLED TO SUPPORT ACHIEVING LEED CREDIT IEQ7.1. THE MECHANICAL SYSTEMS THAT ARE ADDED, ADJUSTED, OR SUPPLEMENTED AS PART OF THE TENANT FIT-OUT SHOULD
ENSURE THAT THE STANDARD REFERENCED IS STILL BEING MET.
THERMAL COMFORT RANGES ARE AS FOLLOWS:
1. TEMPERATURE RANGE : (70-75 DEGREES)+/-2 DEGREES IN SUMMER, (68-72 DEGREES )+/- IN WINTER.
2. HUMIDITY RANGE: 55%+/-, 10% SUMMER, 30% +/- 10% IN WINTER
3. ZONE CONTROL: ALL THERMOSTATS AND HUMIDITY SENSORS ARE LOCATED IN THE ZONE SERVED.
ACOUSTICAL REQUIREMENTS
A. REVERBERATION CONTROL: PRIVATE OFFICE AND CONFERENCE ROOMS USING SUSPENDED ACOUSTICAL CEILINGS SHALL HAVE A NOISE REDUCTION COEFFICIENT (NRC) OF NOT LESS THAN 0.65 IN ACCORDANCE WITH ASTM C-423. OPEN OFFICE USING
SUSPENDED ACOUSTICAL CEILINGS SHALL HAVE AN NRC OF NOT LESS THAN 0.75.
B. AMBIENT NOISE CONTROL: AMBIENT NOISE FROM MECHANICAL EQUIPMENT SHALL NOT EXCEED NOISE CRITERIA CURVE (NC) 35 IN ACCORDANCE WITH THE ASHRAE HANDBOOK OF FUNDAMENTALS IN OFFICES AND CONFERENCE ROOMS. NC 40 I CORRIDORS, CAFETERIAS, LOBBIES, AND RESTROOMS. NC 50 IN OTHER SPACES.
C. NOIsE ISOLATION: ROOMS SEPARATED FROM ADJACENT SPACES BY CEILING HIGH PARTITIONS (NOT INCLUDING DOORS SHALL HAVE NOT LESS THAN THE FOLLOWING NOISE ISOLATION CLASS (NIC) STANDARDS WHEN TRSTED IN ACCORDANCE WITH ATSM E-336.
OCCUPANCY/VACANCY SENSORS
PROVIDE AND INSTALL CEILING MOUNTED OCCUPANCY SENSORS OR VACANCY SENSORS (PREFERRED) OR SCHEDULING CONTROLS THROUGH THE BUILDING AUTOMATION SYSTEM (BAS) THROUGHOUT THE SUITE IN ORDER TO REDUCE THE HOURS THAT THE LIGHTS ARE ON WHEN A PARTICULAR SPACE IS UNOCCUPIED. NO MORE THAN 1000 SQUARE FEET SHALL BE CONTROLLED BY ANY ONE SENSOR. OCCUPANCY SENSORS IN ENCLOSED ROOMS SHALL CONTINUE TO OPERATE AFTER THE BAS HAS SHUT DOWN THE BUILDING AT THE END OF THE WORK DAY. SWITCHES SHOWN IN PLAN ARE MANUAL OVERRIDES. EXISTING SWITCH LOCATIONS
SHALL BE CHANGED TO MANUAL OVERRIDES.
NOTE: REFER TO SHEETS A1.02, A1.03, A1.04, AND A1.05, VA
SPECIFIC GENERAL NOTES, WHICH SUPPLEMENT THE NOTES ON
FE
T
+84 +84
S
+4
+4 4+4
+44
N
N
N
N
N
N
N N
N N
N
NN
N N
NN
N
N
NN
N +44 N +44
N N
N
N N
N
N N
N
N
N
NN
N
N N
N
N N
N
N
N
N
N
N
NN
N
N
N
N
N
N N
N N
DEDN
N +44
N +44
N + 44N +
N
N
N+66"
N N
N+66" N+66"
N+66" N+66" N+66"
N+ 66"
N+ 66"
N+ 66"N
N
N +
N
N N
N
N
N
N GFI
N GFI
N N
N
N
N N N
DEDMW
NN
N
N
N
REF.
REVISIONS
ALIGNED
STUDIO, LLC
ARCHITECTURE + DESIGN
MISSOURI CERTIFICATE OF AUTHORITY
No. 2016030702
DRAWN BY:
REVIEWED BY:
13100 MANCHESTER
JOB NO.
DATE:
CONTACT:
314.317.0060
SUITE 225
ST. LOUIS, MO 63131
www.aligned-studio.com
OF
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
FO
R:
DE
PA
RT
ME
NT
O
F
VE
TE
RA
NS
' A
FF
AIR
S
RE
AD
JU
ST
ME
NT
C
OU
NS
EL
IN
G
SE
RV
ICE
S
NO
RT
H
OU
TE
R
TO
W N
AN
D
CO
UN
TR
Y, MI
SSO
UR
I 6
MICKI WEHMEIER
micki@aligned-studio.com
RANDY WINZEN
randy@aligned-studio.com
1720.1
11.01.17
A3.02
POWER PLAN &
SEISMIC BRACING
DETAILS
RCW
RCW
PARTIAL SECOND FLOOR POWER PLAN
SCALE: 1/8"=1'-0"
POWER PLAN GENERAL NOTES
1. ALL SHADED AREAS INDICATE "NO WORK" OR "NOT IN CONTRACT" UNLESS OTHERWISE NOTED ON PLAN.
2. COORDINATE EXACT LOCATIONS AND REQUIREMENTS OF TENANT PROVIDED FURNITURE COMMUNICATION / ELECTRICAL IN-FEEDS AND WITH TENANT FURNITURE VENDOR PRIOR TO START OF CONSTRUCTION. VERIFY
FLOOR BOX LOCATIONS AND X-RAY SLAB AS REQUIRED.
3. ALL DEVICES ARE EXISTING EXCEPT THOSE DENOTED AS "N" NEW OR "R" RELOCATED. EXISTING
LOCATIONS TO REMAIN UNLESS NOTED OTHERWISE, AND ARE NOT SHOWN ON THIS PLAN.
4. NEW DEVICE AND COVER PLATE COLOR SHALL BE WHITE.
5. ALL CABLING SHALL BE INSTALLED WITH CONDUIT END TO END.
6. PROVIDE AND INSTALL G.F.I. TYPE OUTLETS NEAR WATER SOURCES PER CODE.
7. ALL CABLE WITHIN CEILING CAVITY SHALL BE PLENUM RATED.
8. PROVIDE AND INSTALL 1/2 HP GARBAGE DISPOSAL AND SWITCH.
9. PROVIDE AND INSTALL NEW APPLIANCES INCLUDING ALL ELECTRICAL HOOK-UPS AND DRAINS:
(1) REFRIGERATOR WITH ICEMAKER
(1) MICROWAVE
(1) DISHWASHER
(1) GARBAGE DISPOSAL
APPLIANCES SHALL BE ENERGY STAR RATED. PROVIDE CUT SHEETS FOR TENANT APPROVAL
10. COORDINATE WITH MEP ENGINEER FOR NEW ELECTRICAL PANEL LOCATIONS. EXISTING PANELS TO BE REMOVED DURING DEMOLITION. COORDINATE TEMPORARY POWER TO SUITE FOR USE DURING CONSTRUCTION.
1 PROVIDE CONDUIT FOR CABLE TV AND PULL STRING AT WALL MOUNTED TV BY TENANT.
PROVIDE FLUSH FLOOR DEVICE WIREMOLD-LAGRANGE AV6 SERIES OR EQUAL. VERIFY LOCATIONS AND ALL
REQUIREMENTS WITH TENANT.
TWO POSSIBLE NEW LOCATIONS FOR EXISTING ELECTRIC PANEL SAVED FROM DEMOLITION- EXACT LOCATION TO
BE DETERMINED BY ELECTRICAL DESIGN BUILD CONTRACTOR.
POWER PLAN KEYED NOTES X
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
SES DIRECTOR
OFFICE
CONFERENCE
WORK RM.
TOILET
TOILET
OFFICE
OFFICE
OFFICE
NETWORK
OFFICE
BREAK
ROOM
STOR.
WAITING
COATS
CORRIDOR
CORR.
CORR.
CORR.
CORR.
CORR.
RECEPTION
BUILDING
CORRIDOR
STOR.
CORR.
CORR.
OFFICE
OFFICE
TRAINING/
MULTIPURPOSE
METAL STUD LATERAL BRACING - SCREW ATTACH TO TOP RUNNER
OF PARTITION AND UNDERSIDE OF FLOOR DECK ABOVE WITH (2)
#6 SCREWS AT EACH CONNECTION. CUT AND FOLD STUD WEB AS
NECESSARY FOR CONNECTIONS.
ACOUSTIC CEILING
THIS DETAIL TO BE USED AT ALL 'NEW' PARTITIONS - ALL
PARTITIONS MUST BE BRACED AT 12'-0" O.C.
3.02
SEISMIC BRACING DETAIL
SCALE: 1 1/2"=1'-0"
3'-
4'- 0"
6'- 8"
1"
4"
12"
4'- 0"
3'- 2"
ROLLER LATCHAUDIBLE / VISUAL ALARMS
FIRE EXTINGUISHER
CABINET
POWER / COMMUNICATION
DEVICES (SWITCHES - SIMILAR)
TELEPHONE: MOUNT HIGHEST
OPERABLE PART AT 48" A.F.F.
THERMOSTAT
SWITCH: DASHED LINE INDICATES
LOCATION OF LARGER PLATE FOR
GANGED SWITCHES
DOOR HANDLE
CARD READER
NOTE:
ALL MOUNTING HEIGHTS SHALL
MEET ADA REQUIREMENTS.
MATCH EXISTING HEIGHTS
WHERE POSSIBLE
TYPICAL MOUNTING HEIGHTS
NOT TO SCALE
3.02
SEISMIC BRACING DETAIL
NOT TO SCALE
3.02
ACOUSTICAL CEILING TILE- CUT AS
REQUIRED TO ALLOW LATERAL
BRACING TO INDEPENDENTLY
INTERSECT PARTITION TOP TRACK
PARTITION TOP TRACK
CEILING TEE
NOTE:
ALL WALL PARTITIONS GREATER THAN 6' IN HEIGHT
SHALL BE INDEPENDENTLY BRACED TO THE BUILDING
SHELL STRUCTURE. WALL PARTITIONS MAY NOT BE
SUPPORTED BY THE BRACED SUSPENDED CEILING ALONE.
METAL STUD LATERAL BRACING - SCREW ATTACH TO TOP RUNNER
OF PARTITION AND UNDERSIDE OF FLOOR DECK ABOVE WITH (2)
#6 SCREWS AT EACH CONNECTION. CUT AND FOLD STUD WEB AS
NECESSARY FOR CONNECTIONS.
PARTITION
3.02
METAL STUD LATERAL BRACING - SCREW ATTACH TO TOP
RUNNER OF PARTITION AND UNDERSIDE OF FLOOR DECK
ABOVE WITH (2) #6 SCREWS AT EACH CONNECTION. CUT
AND FOLD STUD WEB AS NECESSARY FOR CONNECTIONS.
ACOUSTIC CEILING
THIS DETAIL TO BE USED AT ALL
'NEW' PARTITIONS - ALL PARTITIONS
MUST BE BRACED AT 12'-0" O.C.
3.02
SEISMIC BRACING DETAIL
SCALE: 1 1/2"=1'-0"
3.02
3.02
ENLARGED NETWORK ROOM PLAN
SCALE: 1/2"=1'-0"
NETWORK
DED
N
DED
+65
(VERIFY)
8'-7"+/-
3'- 2"
1'- 5"
7'-8"
11"+/-
5'-
1/ 4"
1'-5"
6'-0" X 4'-0" X 3/4" TREATED
PLYWOOD PHONE BOARD
RELOCATED SERVER
RACK
RELOCATED WALL MOUNTED
SUPPLEMENTAL HVAC UNIT
2 2
NOTE: ANY NEW OR EXISTING PARTITION THAT HAS A CONTINUOUS UNINTERRUPTED
RUN OF OVER 12'-0" IN LENGTH IS REQUIRED TO HAVE THE TOP OF THE PARTITION
SEISMICALLY BRACED TO THE STRUCTURE ABOVE WITH METAL STUD KICKERS PER THE
DETAILS PROVIDED ON THE DRAWINGS. ANY WALLS WITH INTERSECTING
PERPENDICULAR PARTITIONS AT INTERVALS OF LESS THAT 12'-0" CAN ELIMINATE THE
KICKERS AND ARE NOT REQUIRED TO BE SEISMICALLY BRACED.
NOTE: REFER TO SHEETS A1.02, A1.03, A1.04, AND A1.05, VA
SPECIFIC GENERAL NOTES, WHICH SUPPLEMENT THE NOTES ON
1'- 5"
3'- 0"
BA
R
1'-
6" BA
R
4"
8'- 6"
1'-6" 1'-6"
2'-
6'- 6"
4.01
MEN'S ADA RESTROOM 239
SCALE: 3/8"=1'-0"
4.01 SCALE: 3/8"=1'-0"
9'-6" 8'-0"
8'-
6"GRAB BARS GRAB BARS
TOILET PAPER
DISPENSER
TOILET PAPER
DISPENSER
NEW ADA COMPLIANT
WALL MOUNTED TOILET
NEW ADA COMPLIANT
WALL MOUNTED TOILET
NEW WALL MOUNTED
LAVATORY
BOBRICK 24" X 40", CLEAR TEMPERED
MIRROR IN TOP AND BOTTOM GLAZING
CHANNELS WITH 4" SHELF
INSULATE PIPES
BELOW
MEN'S ADA RESTROOM 239
4'- 0"
CERAMIC TILE
WAINSCOT- TYPICAL
REVISIONS
ALIGNED
STUDIO, LLC
ARCHITECTURE + DESIGN
MISSOURI CERTIFICATE OF AUTHORITY
No. 2016030702
DRAWN BY:
REVIEWED BY:
13100 MANCHESTER
JOB NO.
DATE:
CONTACT:
314.317.0060
SUITE 225
ST. LOUIS, MO 63131
www.aligned-studio.com
OF
CO
NS
TR
UC
TIO
N
DO
CU
ME
NT
S
FO
R:
DE
PA
RT
ME
NT
O
F
VE
TE
RA
NS
' A
FF
AIR
S
RE
AD
JU
ST
ME
NT
C
OU
NS
EL
IN
G
SE
RV
ICE
S
NO
RT
H
OU
TE
R
TO
W N
AN
D
CO
UN
TR
Y, MI
SSO
UR
I 6
MICKI WEHMEIER
micki@aligned-studio.com
RANDY WINZEN
randy@aligned-studio.com
1720.1
11.01.17
A4.01
ENLARGED PLANS
AND INTERIOR
ELEVATIONS
RCW
RCW
ENLARGED RESTROOM PLANS
SCALE: 3/8"=1'-0"
4.01
8'- 0"
1'- 0"
8'- 7"
3'-4"
4'-2" 3 3/4" 9'-6"+/-
9'- 0"
3/ 4"
7'-
1/ 2"
2'-0"+/-
5'-
1/ 2"
13'-10 1/2"+/-
1'-6" 7'-6"
1'-6" 1'-6"
2'-6 1/2"+/-
1'-6" (MIN.)
4.01
4.01 2
4.01 4
4.01
ADA
MEN
ADA
WOMEN
CORR.
CORR.
3 2
F
F
3/ 4"
1'-
1/ 4"
3'-0"
BAR
6"
PAPER TOWEL DISPENSER
AND DISPOSAL
4'-3" 1'- 5"
3'- 0"
BA
R
4" 1'-
6" BA
R
3'-6"
BAR
1'-0"
3'-4"
3'-0"
1'- 7"
3'-6"
BAR
1'-0"
3'-4"
2'- 6"
10"
4.01 SCALE: 3/8"=1'-0"
8'-7"
8'- 6"
TOILET PAPER
DISPENSER
WOMEN'S ADA RESTROOM 240
4'- 0"
CERAMIC TILE
WAINSCOT- TYPICAL
1'- 5"
3'- 0"
BA
R
1'-
6" BA
R
4" 8'-
6"
1'-6"
7'-6"
2'-
6'- 6"
4.01
WOMEN'S ADA RESTROOM 240
SCALE: 3/8"=1'-0"
13'-10 1/2"+/-
GRAB BARS
TOILET PAPER
DISPENSER
NEW ADA COMPLIANT
WALL MOUNTED TOILET
NEW WALL MOUNTED
LAVATORY
INSULATE PIPES
BELOW
CERAMIC TILE
WAINSCOT- TYPICAL
3'-0"
BAR
6"
PAPER TOWEL DISPENSER
AND DISPOSAL
5'-0"
1'-6"
GRAB BARS
NEW ADA COMPLIANT
WALL MOUNTED TOILET
1'- 5"
3'- 0"
BA
R
4" 1'-
6" BA
R
CERAMIC TILE
WAINSCOT- TYPICAL
FEMININE NAPKIN
DISPOSAL
5'-8 3/4" 2'-6" 2'-9" 2'-6" 1 1/2"
1'-1"
14'-8 1/4"
2'-6" 1'-9" 2'-6" 2 1/2"
2'-0"
3'- 0"
1'- 8"
2'- 6"
1'- 4"
8'-
6" PLASTIC LAMINATE
COUNTERTOP
PLASTIC LAMINATE WALL CABINETS
WITH ADJUSTABLE SHELVES
PLASTIC LAMINATE BASE CABINETS
WITH ADJUSTABLE SHELF
FILLER
FINISHED END
PANEL
DRAWER UNIT
FINISHED END
PANEL
4.01 SCALE: 3/8"=1'-0"
WORK ROOM 221
9'-8 1/2"
1'-1" 1 3/4"
2'-6" 2'-3" 2'-6" 1 3/4"
1'-1"
3'- 0"
1'- 8"
2'- 6"
1'- 4"
2'-0" 1 1/4"
2'-9" 2'-9" 1 1/4"
2'-0"
FILLER
PLASTIC LAMINATE
COUNTERTOP
PLASTIC LAMINATE BASE
CABINETS WITH
ADJUSTABLE SHELF
PLASTIC LAMINATE WALL
CABINETS WITH
ADJUSTABLE SHELVES
FILLER 8'-
6"
4.01 SCALE: 3/8"=1'-0"
WORK ROOM 221
2'-6"2'-9"2'-6" 1 1/2"
1'-1"
14'-8 1/4"
2'-6"1'-9"2'-6" 2 1/2"
2'-0"
3'- 0"
1'- 8"
2'- 6"
1'- 4"
8'- 6"
PLASTIC LAMINATE
COUNTERTOP
PLASTIC LAMINATE WALL CABINETS
WITH ADJUSTABLE SHELVES
PLASTIC LAMINATE BASE CABINETS
WITH ADJUSTABLE SHELF
FILLER
DRAWER UNIT
7/8"
FILLER
7/8" 1'-4" 4'-4"+/-
FILLER
4.01 SCALE: 3/8"=1'-0"
WORK ROOM 221
KEYED NOTES #
ADA COMPLIANT ELECTRIC SENSOR FAUCET: KOHLER OR EQUAL
WALL MOUNTED WATER CLOSET MOUNTED AT 17" A.F.F. TO RIM: KOHLER OR EQUAL,
ELONGATED, COLOR- WHITE WITH BATTERY OPERATED FLUSH VALVE.
WALL MOUNTED SINK MOUNTED AT 34" A.F.F.: KOHLER OR EQUAL
TOILET PAPER DISPENSER: BOBRICK OR EQUAL SURFACE MOUNTED MULTI-ROLL TOILET
TISSUE DISPENSER IN SATIN STAINLESS STEEL FINISH.
FEMININE NAPKIN DISPOSAL: BOBRICK OR EQUAL SURFACE MOUNTED SANITARY NAPKIN
DISPOSAL IN SATIN STAINLESS STEEL FINISH.
BOBRICK #B-5806 X 18- 18" STRAIGHT GRAB BAR IN SATIN STAINLESS STEEL FINISH.
BOBRICK #B-5806 X 36- 36" STRAIGHT GRAB BAR IN SATIN STAINLESS STEEL FINISH.
BOBRICK #B-5806 X 42- 42" STRAIGHT GRAB BAR IN SATIN STAINLESS STEEL FINISH.
NEW FLOOR DRAIN- SEE PLUMBING DESIGN BUILD DRAWINGS.
FRAMELESS 24" X 48" MIRROR- VERIFY EXACT REQUIREMENTS WITH TENANT.
ALIGN NEW CONSTRUCTION WITH EXISTING IN SAME PLANE WITH NO VISIBLE JOINTS.
ADA ACCESSIBLE SEMI RECESSED PAPER TOWEL DISPENSER AND RECEPTACLE: BOBRICK
OR EQUAL.
WALL MOUNTED SOAP DISPENSER WITH ELECTRIC SENSOR- BOBRICK OR EQUAL.
4.01 SCALE: 3/8"=1'-0"
TYPICAL DOOR & SIDELIGHT
2"3'-0"2" 10" 1'-6"
7'- 2"
DOOR HEIGHT TEMPERED
GLASS SIDELIGHT
TYPICAL OFFICE DOOR
2"
TYP.
4.01
DETAIL AT COAT ROD AND SHELF
SCALE: 1 1/2"=1'-0"
1'-0" 6"
NOTE: A.D.A. INCLUDES HOOK AT
48" A.F.F. AT EACH SIDE WALL
SEE PARTITION TYPES
3/4" BIRCH VENEER PLYWOOD
(PAINT TO MATCH WALL)
1 x 4 HARDWOOD EDGE
(PAINT TO MATCH WALL)
KNAPE & VOGT #770 1 1/16" O.D.
TUBING WITH #734 AND #735
BRACKETS (TYPICAL) OR EQUAL
METAL ROD/SHELF BRACKET AT C.L. OF SPAN (SPANS
OVER 6'-0": SPACE AT 3'-0" O.C. MAXIMUM)
1 x NO. 1 GRADE (PAINT TO MATCH WALL)
COUNTERSINK SCREWS AND CONCEAL
2 x 4 FIRE RETARDANT TREATED WOOD
BLOCKING SECURE TO STUDS
1/ 4"
5'- 6"
A .F.
F.
3'- 0"
2"
2x FIRE RETARDANT TREATED
WOOD BLOCKING IN PARTITION
SCHEDULED PLASTIC LAMINATE OR SOLID
SURFACE COUNTERTOP AND BACKSPLASH
(WHERE APPLICABLE)
1/ 2"
SCHEDULED PLASTIC LAMINATE
EXTERIORS ALL EXPOSED SURFACES
INTERIORS WHITE MELAMINE
4"
3"
SCHEDULED PLASTIC
LAMINATE TOE KICK
6" 6"
6" 1'-
1/ 2"
18" DRAWER DEPTH - TYPICAL
2'-1"
1/2"
NOTE:
SCRIBE ALL MILLWORK TO
ADJACENT SURFACES
4.01
SECTION AT BASE CABINET
SCALE: 1"=1'-0" DRAWER UNIT
4.01
SECTION AT BASE CABINET
SCALE: 1"=1'-0" WITH DRAWER
2x FIRE RETARDANT TREATED
WOOD BLOCKING IN PARTITION
SCHEDULED PLASTIC LAMINATE
OR SOLID SURFACE
COUNTERTOP AND BACKSPLASH
(WHERE APPLICABLE)
2"
2'-1"
3/4"1'-10"
6" 1 1/ 2"
INTERIORS WHITE MELAMINE
PROVIDE (1) 18" DEEP
ADJUSTABLE SHELF WITH HAFELE
#282.04.711 SHELF SUPPORTS
AND HOLES AT 3" O.C. SPACING
SCHEDULED PLASTIC
LAMINATE TOE KICK
4"
3"
NOTE:
SCRIBE ALL MILLWORK TO
ADJACENT SURFACES
SCHEDULED PLASTIC
LAMINATE EXTERIORS ALL
EXPOSED SURFACES
3/4"1/2"
2x FIRE RETARDANT TREATED
WOOD BLOCKING IN PARTITION
1'-1"
12"1/4"
2'- 6"
(S
EE
IN
TE
RIO
R
EL
EV
AT
IO
NS
PROVIDE (2) 11" DEEP ADJUSTABLE
SHELVES WITH HAFELE #282.04.711
SHELF SUPPORTS AND HOLES AT 1" O.C.
SPACING
PLASTIC LAMINATE EXTERIOR AND
TWO SIDES AND ALL EDGES
INTERIOR: WHITE MELAMINE
COUNTERTOP BELOW (WHERE OCCURS)
4.01
SECTION AT WALL CABINET
SCALE: 1"=1'-0"
W
HE
RE
C
OU
NT
ER
TO
P
EX
IST
S
1'-1"
VERIFY SOFFIT DEPTH
2'-
4"
SCHEDULED PLASTIC LAMINATE OR SOLID
SURFACE COUNTERTOP AND BACKSPLASH
18" REMOVABLE (LIFT OFF) ADA FRONT PANEL-
LOCATE FOR MAXIMUM CLEARANCE BELOW.
HARDWARE: BULLDOG CABINET CATCH #655
8"
MIN.
11"
MIN.
2'- 5"
1'-5"
9"
5"
1'- 6"
REQUIRED ADA KNEE CLEARANCE (SHOWN HATCHED)
REQUIRED ADA TOE CLEARANCE (SHOWN HATCHED)
GARBAGE DISPOSAL: INSINKERATOR
BADGER 5
2"
PLASTIC LAMINATE BACK PANEL
NOTE: CONTRACTOR TO VERIFY REQUIRED
ADA TOE AND KNEE CLEARANCES AT
TIME OF FABRICATION/INSTALLATION
6"
MAX.
NOTE:
SCRIBE ALL MILLWORK TO ADJACENT SURFACES
2x FIRE RETARDANT TREATED
WOOD BLOCKING IN PARTITION
2'-1"
ELKAY GECR-2521 L OR R
STAINLESS STEEL SINK WITH GOOSENECK
FAUCET AND LEVER STYLE HANDLES
NOTE:
SCRIBE ALL MILLWORK
TO ADJACENT SURFACES
1/ 2"
4.01
SECTION AT SINK CABINET
SCALE: 1"=1'-0"
3'- 0"
SCHEDULED CEILING
(5) 15" DEEP x 3/4" THICK HIGH
DENSITY FIBERBOARD SHELVES WITH
MELAMINE FINISH ALL SIDES
KNAPE & VOGT 87 SERIES SUPER DUTY STANDARDS AT
32" O.C. (2" VERTICAL ADJUSTMENT SLOTS) WITH KNAPE
& VOGT 187 SUPER DUTY METAL SHELF BRACKETS
SCHEDULED BASE
SCHEDULED FLOOR FINISH
3/4" FIRE RETARDANT TREATED PLYWOOD OR 2x4 FIRE
RETARDANT TREATED BLOCKING BETWEEN STUDS. SECURE
TO STUDS AT TOP MIDDLE, AND BOTTOM OF WALL
4.01
SECTION AT ADJUSTABLE SHELVES
SCALE: 1"=1'-0"
8'- 6"
V
ER
IFY
1/ 2"7"1'-0"
2'-1"
2"
8" WIDE FIRE RETARDANT TREATED
PLYWOOD BLOCKING IN PARTITION
SCHEDULED PLASTIC LAMINATE
COUNTERTOP AND BACKSPLASH
6"
SCHEDULED BASE
'L' FLOOR CLIP. SET IN
MORTISE IN PANEL
INTERMEDIATE PLASTIC LAMINATE
SUPPORT PANEL AT 4'-0" O.C.
MAX. SEE PLAN WHERE OCCURS
3/4" x 3/4" HARDWOOD CLEAT
4.01
SECTION AT COUNTERTOP
SCALE: 1"=1'-0"
NOTE: PROVIDE ONLY THREE DRAWERS