072720-VA Break Room Casework Revisions.pdf
PDF 337 KB Posted
- Attached to
- Security System Installation and Monitoring Federal contract opportunity
- Solicitation number
- 36C25521Q05350001
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 072820-VA Break Room Bid Set.pdf | ||
| 110117 Original Floor Plans.pdf | ||
| 36C25521Q0535 0001.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
S
S
S
S
S
CR
S
N
N
N+42"N+42"
1' -6
(M
IN
.) 4'
-8
/4
4'-0"
B
A
A
A
A
A
A
A
A
7'- 0"
P
P
P
P2
P2
P2
ABOVE
START P-2
2.01
VHASTLBrownJ1 Pencil
DEMO/REMOVE EXISTING PARTITION INCLUDING ALL ELECTRICAL/ DATA WIRING/CABLING BACK TO ITS
SOURCE PANEL.
DEMO/REMOVE EXISTING DOOR AND FRAME AS REQUIRED. TURN OVER TO BUILDING STOCK OR DISPOSE
OF AS DIRECTED BY BUILDING MANAGER.
DEMO/REMOVE EXISTING GLASS BORROW LIGHT AND FRAME (WHERE APPLICABLE). MODIFY AS
REQUIRED TO ACCOMMODATE NEW CONSTRUCTION.
REMOVE EXISTING CEILING TILE AND GRIDS IN HATCHED AREA. PROVIDE SUPPORT TO ANY GRIDS TO
REMAIN AND PREPARE FOR NEW PARTITIONS TO BE ERECTED.
DEMO/REMOVE EXISTING CARD READER INCLUDING ALL WIRING/CABLING BACK TO ITS SOURCE PANEL-
PATCH REMAINING WALL SURFACES AS REQUIRED AND TURN CARD READER OVER TO TENANT.
REMOVE EXISTING OUTLET AND DATA JACK ONLY IF IN CONFLICT WITH NEW CONSTRUCTION- VERIFY
WITH TENANT IF IT IS TO BE RELOCATED.
REMOVE AND RELOCATE EXISTING LIGHT AND/OR EMERGENCY/EXIT LIGHT TO NEW LOCATION- SEE
REFLECTED CEILING PLAN.
EXISTING CASEWORK TO REMAIN- PROTECT DURING CONSTRUCTION.
1. ALL SHADED AREAS INDICATE "NO WORK" OR "NOT IN CONTRACT" UNLESS OTHERWISE NOTED ON PLAN.
2. REMOVE ALL EXISTING AREAS INDICATED AS DEMOLITION TO PROVIDE LAYOUT SHOWN. CONSTRUCT AND/OR PROVIDE PROTECTION BARRIERS AS NEEDED FOR SAFETY AND TO CONTAIN DUST DUE TO DEMOLITION AND KEEP
3. PATCH AND REPAIR REMAINING SURFACES AS NEEDED DUE TO THE DEMOLITION OR THE REMOVAL OF
4. REPAIR HOLES IN EXISTING PARTITIONS TO REMAIN WHERE PARTITION MOUNTED ITEMS ARE TO BE REMOVED. REFER TO FINISH PLAN FOR SCHEDULED FINISH. WHERE PARTITION, EQUIPMENT OR ACCESSORIES, ETC. ARE REMOVED AND NO REPLACEMENT FINISH IS CALLED FOR, PATCH AND REPAIR TO MATCH ADJACENT
5. REMOVE ALL DEMOLISHED MATERIALS FROM THE BUILDING AND THE SITE. ALL DEMOLISHED MATERIALS,
6. REMOVE ANY AND ALL EXISTING ELECTRICAL AND COMMUNICATION EQUIPMENT, SWITCHES, RECEPTACLES, NOT SHOWN ON THE DRAWINGS AND THAT ARE NOT IN USE IN AREAS OF WORK FROM WITHIN PARTITIONS AND ABOVE THE SCHEDULED CEILING. ALL WIRING SHALL BE REMOVED BACK TO ITS SOURCE PANEL.
7. SALVAGE AND STORE EXISTING DOORS AND FRAMES AND OTHER ITEMS CALLED OUT TO BE RELOCATED.
MODIFY AS REQUIRED. REPAIR ANY DAMAGE TO ALL EXISTING SURFACES AND ITEMS BEING SALVAGED FOR REUSE. RETURN UNUSED MATERIALS TO BUILDING STORAGE AS DIRECTED BY BUILDING MANAGEMENT.
8. PHASE ALL WORK SO THAT EXISTING MEANS OF EGRESS TO REMAIN IN EFFECT DURING CONSTRUCTION.
PRIOR TO CONSTRUCTION COMMENCEMENT, A PROPOSED PLAN FOLLOWING INDUSTRY STANDARDS TO RECYCLE CONSTRUCTION AND DEMOLITION WASTE SHALL BE PREPARED. THE CONSTRUCTION WASTE MANAGEMENT PLAN SHALL QUANTIFY MATERIAL DIVERSION GOALS AND MAXIMIZE THE MATERIALS TO BE RECYCLED AND/OR SALVAGED (AT LEAST 50%) FROM CONSTRUCTION, DEMOLITION, AND PACKAGING DEBRIS. WHERE THE SMALL QUANTITY OF MATERIAL, THE EXTRAORDINARILY COMPLEX NATURE OF THE WASTE DISPOSAL METHOD, OR PROHIBITIVE EXPENSE FOR RECYCLING WOULD REPRESENT A GENUINE HARDSHIP, THE GOVERNMENT, UPON WRITTEN REQUEST OF THE LESSOR AND APPROVAL OF THE LEASE CONTRACTING OFFICER MAY PERMIT ALTERNATIVE MEANS
CARPET RECLAMATION: RECLAMATION OF EXISTING CARPET TO BE DETERMINED WITH POTENTIAL VENDOR.
WHERE CARPET IS REPLACED, SUBMIT CERTIFICATION DOCUMENTATION FROM THE RECLAMATION FACILITY TO THE
CONSTRUCTION WASTE MANAGEMENT PLAN
1. ALL SHADED AREAS INDICATE "NO WORK" OR "NOT IN CONTRACT" UNLESS OTHERWISE NOTED ON PLAN.
2. ALL PARTITIONS SHALL BE "P1" UNLESS OTHERWISE NOTED ON PLAN. SEE SEISMIC DETAILS 2, 6 & 10/A3.01
AND PARTITION TYPES, SHEET A3.01.
3. ALL ANGLES SHALL BE 90 OR 45 DEGREES UNLESS OTHERWISE NOTED ON PLAN.
4. ALL OPENINGS TO BE MINIMUM 3'-0" WIDE CLEAR UNLESS OTHERWISE DIMENSIONED ON PLAN.
5. PROVIDE AND INSTALL FIRE RETARDANT WOOD BLOCKING IN WALL FOR ALL BUILT-IN MILLWORK, TYPICAL.
6. ALL GLAZING SHALL BE TEMPERED. SEE PLAN AND\/OR ELEVATIONS FOR SPECIFIC GLASS WIDTH DIMENSIONS.
ORDER ALL GLASS WITHOUT MANUFACTURERS STAMP AND FREE OF BLEMISHES AND TONG MARKS.
7. GENERAL CONTRACTOR TO COORDINATE ALL HORN STROBE AND/OR FIRE ALARM PULL STATION LOCATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. GC MUST USE BUILDING STANDARD FIRE ALARM DEVICES WHEN FURNISHING ADDITIONAL FIRE ALARM DEVICES AND MUST USE A LANDLORD APPROVED SIMPLEX CONTRACTOR FOR
MAKING CONNECTIONS TO THE FIRE ALARM SYSTEM.
8. PROVIDE AND INSTALL NEW VERTICAL BLINDS AT ALL EXTERIOR WINDOWS. WAND OPERATION ONLY. NO
CORDS WILL BE PERMITTED.
ENVIRONMENTALLY PREFERABLE
PRODUCT REQUIREMENTS
A. THE GC MUST PROVIDE ENVIRONMENTALLY PREFERABLE PRODUCTS AS DETAILED THROUGHOUT THE SUITE.
(I.E.: PLUMBING FIXTURES,WATER CONSERVATION)
B. WHEN THE DRAWINGS DO NOT CONTAIN SPECIFIC REQUIREMENTS FOR ENVIRONMENTALLY PREFERABLE PRODUCTS, THE GC MUST PROVIDE PRODUCTS MEETING ONE OF THE BELOW ENVIRONMENTALLY PREFERABLE CRITERIA WHEN SUCH PRODUCTS ARE AVAILABLE. THE GC CAN CONSULT THE GREEN PROCUREMENT COMPILATION AT WWW.SFTOOL.GOV/GRENPROCUREMMENT TO DETERMINE WHETHER ANY OF THESE CRITERIA ARE
APPLICABLE FOR A PRODUCT CATEGORY.
1. BIO-PREFERRED PRODUCTS
2. ENERGY STAR PRODUCTS
3. EPA COMPREHENSIVE PROCUREMENT GUIDELINE DESIGNATED (RECYCLED CONTENT) PRODUCTS
4. EPA SAFER CHOICE LISTED PRODUCTS
5. FEMP-DESIGNATED ENERGY EFFICIENT PRODUCTS
6. SNAP (SIGNIFICANT NEW ALTERNATIVE POLICY) SUBSTANCES
7. WATER SENSE OR OTHER WATER EFFICIENT PRODUCTS.
C. THE GC, IF UNABLE TO COMPLY WITH THE ENVIRONMENTALLY PREFERABLE PRODUCT REQUIREMENTS ABOVE, MUST SUBMIT A WAIVER REQUEST FOR EACH MATERIAL WITHIN THE TI PRICING SUBMITTAL. THE WAIVER
REQUEST SHALL BE BASED ON THE FOLLOWING EXCEPTIONS:
1. PRODUCT CANNOT BE ACQUIRED COMPETITIVELY WITHIN A REASONABLE PERFORMANCE SCHEDULE.
2. PRODUCT CANNOT BE ACQUIRED THAT MEETS REASONABLE PERFORMANCE REQUIREMENTS.
3. PRODUCT CANNOT BE ACQUIRED AT A REASONABLE PRICE.
4. AN EXCEPTION IS PROVIDED BY STATUTE.
THE PRICE SHALL BE DEEMED UNREASONABLE WHEN THE TOTAL LIFE CYCLE COSTS ARE SIGNIFICANTLY HIGHER FOR THE SUSTAINABLE PRODUCT VERSUS THE NON- SUSTAINABLE PRODUCT. LIFE CYCLE COSTS ARE DETERMINED BY COMBINING THE INITIAL COSTS OF A PRODUCT WITH ANY ADDITIONAL COSTS OR REVENUES GENERATED FROM
THAT PRODUCT DURING ITS ENTIRE LIFE.
2.01
BREAK ROOM
SCALE: 3/8"=1'-0"
12'-7 1/4"+/-
1'-6 1/4" 2'-6" 1'-6" 3'-0" 1'-6" 2'-6" 1"
1'-6 1/4" 2'-6" 1'-6" 3'-0" 1'-6" 2'-6"
3' -0
1' -6
2' -6
1' -6
8' -6
PLASTIC LAMINATE BASE CABINETS
WITH ADJUSTABLE SHELF
PLASTIC LAMINATE WALL CABINETS
WITH ADJUSTABLE SHELVES
PLASTIC LAMINATE COUNTERTOP
WITH 2" BACKSPLASH
FINISHED END PANEL
FINISHED END PANEL
DRAWER UNIT DRAWER UNIT
3.01
3.01
3.01
SCHEDULED BASE
SCHEDULED FLOOR FINISH
PARTITION TYPE
SCALE: 1 1/2"=1'-0"
PARTITION TYPE
SCALE: 1 1/2"=1'-0"P2
SCHEDULED BASE
SCHEDULED FLOOR FINISH
8. ALL SWITCHES AND DIMMERS (WHERE OCCURS) AT SAME LOCATION SHALL MATCH IN SAME STYLE AND FINISH. DEVICE COLOR SHALL MATCH WHITE.
REPLACE ALL DEVICES AND COVER PLATES AS REQUIRED TO MATCH WHITE. LOCATE NEW SWITCHES 6" TO CENTERLINE FROM DOOR JAMB UNLESS
OTHERWISE NOTED, OR IF A SIDELIGHT IS SCHEDULED.
9. MECHANICAL ENGINEER TO ENSURE THAT THE SUITE'S MECHANICAL SYSTEM IS DESIGNED AND INSTALLED TO MAINTAIN THERMAL ENVIRONMENTAL
CONDITIONS FOR HUMAN OCCUPANCY AS ESTABLISHED BY ASHRAE STANDARD 55-2004.
10. MECHANICAL SYSTEM IS TO BE BALANCED BY A THIRD PARTY LANDLORD-APPROVED AIR BALANCING CONTRACTOR.
11. TIE LIFE SAFETY LIGHTING AND ALARMS INTO BUILDING STANDARD SECURITY SYSTEM.
3' -0
2"
2x FIRE RETARDANT TREATED
WOOD BLOCKING IN PARTITION
SCHEDULED PLASTIC LAMINATE
COUNTERTOP AND BACKSPLASH
1/ 2"
SCHEDULED PLASTIC LAMINATE
EXTERIORS ALL EXPOSED SURFACES
INTERIORS WHITE MELAMINE
4"
3"
SCHEDULED PLASTIC LAMINATE TOE KICK
6" 6"
6"
/2
18" DRAWER DEPTH - TYPICAL
2'-1"
1/2"
NOTE:
SCRIBE ALL MILLWORK TO
ADJACENT SURFACES
3.01
SECTION AT BASE CABINET
SCALE: 1"=1'-0" DRAWER UNIT
3' -0
2"
2x FIRE RETARDANT TREATED
WOOD BLOCKING IN PARTITION
SCHEDULED PLASTIC LAMINATE
COUNTERTOP AND BACKSPLASH
1/ 2"
SCHEDULED PLASTIC LAMINATE
EXTERIORS ALL EXPOSED SURFACES
INTERIORS WHITE MELAMINE
PROVIDE (1) 18" DEEP ADJUSTABLE SHELF
WITH HAFELE #282.04.711 SHELF
SUPPORTS AND HOLES AT 3" O.C. SPACING
4"
3"
SCHEDULED PLASTIC LAMINATE TOE KICK
2'-1"
3/4"3/4" 1'-11"1/2"
NOTE:
SCRIBE ALL MILLWORK TO ADJACENT SURFACES
3.01
SECTION AT BASE CABINET
SCALE: 1"=1'-0"
2x FIRE RETARDANT TREATED
WOOD BLOCKING IN PARTITION
1'-1"
12"1/4"
2' -6
PROVIDE (2) 11" DEEP ADJUSTABLE SHELVES
WITH HAFELE #282.04.711 SHELF SUPPORTS
AND HOLES AT 1" O.C. SPACING
PLASTIC LAMINATE EXTERIOR AND
TWO SIDES AND ALL EDGES
INTERIOR: WHITE MELAMINE
COUNTERTOP BELOW (WHERE OCCURS)
3.01
SECTION AT WALL CABINET
SCALE: 1"=1'-0"
W
HE
RE
C
OU
NT
ER
TO
P
EX
IS
TS
1'-1"
VERIFY SOFFIT DEPTH
| 072720-Break Room Casework Floor Plan |
| Sheets and Views |
| Model |
| 072720-Break Room Casework Elevation |
| Sheets and Views |
| Model |
| 072720-Break Room Casework Details |
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .