1017_Second_Ct_ROOF_-_STRIP_AND_INSTALL_(7).docx

DOCX document 40 KB Posted

Attached to
1017 Second Ct - Replace Roof & Gutterwork on Home & Garage
Solicitation number
2026-COMMUNITY DEVELOPMENT-045
Issued by
Kalamazoo County, Huntington Woods City, Michigan

About this file

This work write-up is a scope of work document prepared by the City of Jackson Community Development Department in Michigan for roof and gutterwork repairs at 1017 Second Court, Jackson, MI 49203, for property owner Jonathan Allaband. The project encompasses three primary work items: roof stripping and installation on a garage structure (approximately 4 squares), roof stripping and installation on the main home structure (approximately 20 squares), and gutterwork installation. The roof work includes removal of existing shingles and felt, repairs to roof framing as needed, installation of 7/16" oriented-strand board sheathing, ice shield protection extending 24" per Michigan Building Code requirements, 15% asphalt saturated felt, new architectural-style shingles, metal drip and rake edges, valley flashing, chimney and plumbing vent reflashing, and ridge venting. The gutterwork specification calls for approximately 100 linear feet of baked pre-enameled aluminum K-type gutter and approximately 80 linear feet of commercial-size downspouts. Both roof items are marked as requiring permits. The document was prepared by sharrison@cityofjackson.org on August 12, 2026, and requires contractor and owner signatures upon execution as part of a construction contract.

The work write-up establishes that contractors must provide final measurements and select roofing material colors and manufacturers to be approved by the owner. Gutter installations must maintain proper pitch and include appropriate water diversion measures away from the foundation. All work must comply with manufacturer specifications and applicable building codes. The document indicates that projects are awarded to qualified, lowest-bid contractors who maintain Sam.gov registration, proper licensing, and obtain required permits. No pricing information, timeline for bid submission, award dates, or contract term duration is specified in this scope of work document.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Work Write-Up

R05 - ROOF - STRIP AND INSTALL

* EXHIBIT 1 *

Dated: 8/12/2026

CUSTOMER INFORMATION

Jonathan Allaband 1017 2nd Ct, Jackson, MI 49203

PREPARED BY

sharrison@cityofjackson.org

* NOTE *

THE CUSTOMER AND CONTRACTOR MUST SIGN THE BOTTOM OF EACH PAGE ONLY IF

1) THIS WORK WRITE-UP BECOMES PART OF A CONSTRUCTION CONTRACT

2) THE UNDERSIGNED CUSTOMER AND CONTRACTOR HAVE REVIEWED, APPROVED AND AGREED TO THE WORK AND PRICES DESCRIBED IN THIS WORK WRITE-UP

Location: Unassigned

General Requirements
Quantity
Units
Total

1 - R05 - ROOF - STRIP AND INSTALL Garage (Specification ID:1.05000 )

* PERMIT REQUIRED *

Strip existing roof, removing all shingles and felt. Make repairs to the existing roof framing where required to provide adequate strength and a true and level surface. Install 7/16” oriented-strand board sheathing to cover all areas of roof deck. Just before proceeding, sweep roof thoroughly to remove all debris. Install ice shield at all lower roof edges. Ice shield shall extend at least 24" inside the interior surface of the exterior wall line of the building, in accordance with the Michigan Building Code. Install new 15% asphalt saturated felt according to manufacturer's directions. Furnish and install new roofing material of a color as selected by owner, must be architectural style. Installation shall include metal drip and rake edge, two layers of 90# roll valley or metal valley in all valleys. Reflash chimney, plumbing vents, and vertical walls with appropriate neoprene boots and metal step flashing where possible. Install ventilation units sufficient to vent all areas of attic. Ridge venting when used shall cover the full length of the roof ridge. Installation of all materials shall follow manufacturer's printed instructions and G.S. 1.

Contractor is responsible for final measurement.

Approximately 4 squares on all elevation New roofing material type shall be architectural shingles Manufacturer: __________ Color Name/Number: __________ Contractor's Initials: ____________________ Owner's Initials: __________ Rehab: _____________

2 - R05 - ROOF - STRIP AND INSTALL Home (Specification ID:1.05000 )

* PERMIT REQUIRED *

Strip existing roof, removing all shingles and felt. Make repairs to the existing roof framing where required to provide adequate strength and a true and level surface. Install 7/16” oriented-strand board sheathing to cover all areas of roof deck. Just before proceeding, sweep roof thoroughly to remove all debris. Install ice shield at all lower roof edges. Ice shield shall extend at least 24" inside the interior surface of the exterior wall line of the building, in accordance with the Michigan Building Code. Install new 15% asphalt saturated felt according to manufacturer's directions. Furnish and install new roofing material of a color as selected by owner, must be architectural style. Installation shall include metal drip and rake edge, two layers of 90# roll valley or metal valley in all valleys. Reflash chimney, plumbing vents, and vertical walls with appropriate neoprene boots and metal step flashing where possible. Install ventilation units sufficient to vent all areas of attic. Ridge venting when used shall cover the full length of the roof ridge. Installation of all materials shall follow manufacturer's printed instructions and G.S. 1.

Contractor is responsible for final measurement.

Approximately 20 squares on all elevation New roofing material type shall be architectural shingles Manufacturer: __________ Color Name/Number: __________ Contractor's Initials: ____________________ Owner's Initials: __________ Rehab: ____________

3 - G08 - GUTTERWORK

(Specification ID:1.08000 )

LF

Furnish and install gutter and downspout. Replacements shall match existing as to materials, finish, shape and size. Do not mix galvanized with copper or aluminum. Where replacements are of a complete system or side of a system having no cross connections with sections not to be replaced, used baked pre-enameled aluminum, 5 inch K-type in standard colors. Minimum thickness of aluminum shall be .027 inches for troughs and fittings. Use one or a combination of strap hangers, spike and ferrules or fascia hangers. Space hangers and slip joint connectors per manufacturer's instructions. Maximum spacing of hangers shall be 48 inches OC for galvanized and 30 inches for aluminum. Use only recommended gutter seal and rivets or screws at all joints. All work, whether a complete new system or a partial replacement, shall have the system with a pitch of not less than 1 inch in 16 feet. Divert the water away from the foundation using appropriate extensions and/or concrete splash blocks. All work to conform to code and G.S. 4a.

Contractor responsible for final measurements.

All Downspouts shall be commercial size.

Approximately 100 linear feet of gutter on all elevation(s).

Approximately 80 linear feet of downspout on all elevation(sn) .

Subtotal for General Requirements

Total

Prepared By: sharrison@cityofjackson.org on 8/12/2026

OWNER ACCEPTS SCOPE OF WORK

I have read the contents of this work write up and received a copy. I fully understand the repairs to be made to my property.

x___________________________________
Owner:Date

CONTRACTOR ACCEPTS SCOPE OF WORK

I have read the contents of this work write up and agree to perform all work called for in accordance with the bid submitted on __________.

x___________________________________
ContractorDate
x______________________________________
Construction SpecialistDate