(10) ROOF DRAIN DETAIL (1).pdf

PDF 248 KB Posted

Attached to
ROOF RENOVATION - ROOF SECTIONS
Solicitation number
RFP BEAL 180000002414 1
Issued by
Ingham County, Michigan

About this file

This is a technical specification document for the LA-PR-24 roofing project, detailing roof drain installation and waterproofing requirements. The project involves the restoration and installation of a liquid-applied waterproofing system around an existing roof drain assembly. The scope includes removal of existing flashings, installation of new fluid-applied systems, and integration of reinforcement materials into a cast-iron drain bowl with clamping ring and drain strainer. Key specifications require priming of the substrate per manufacturer recommendations, full saturation or encapsulation of reinforcement in base coat, trimming of existing flashings to the bowl transition point, and extension of the liquid-applied system into the drain. The reinforcement must be cut into triangular pieces that overlap into the bowl, with new flashings fully encapsulating old flashings.

The document emphasizes substrate preparation and quality control measures, including cleaning existing roof membranes to bright metal and applying primer before installation of new systems. The liquid-applied base coat serves as the primary waterproofing material with reinforcement to ensure durability and proper water drainage. Existing insulation and restoration deck clamp details are noted as integration points. No pricing information, contract timeline, bidding requirements, or award details are included in this technical specification sheet, which functions as a construction detail guide rather than a solicitation or contract agreement document.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LA-PR-24

NOTES

1. PRIMING OF THE SUBSTRATE MAY BE REQUIRED, FOLLOW SPECIFICATIONS AND MANUFACTURER

RECOMMENDATIONS.

2. REINFORCEMENT MUST BE FULLY SATURATED OR ENCAPSULATED IN BASE COAT AS DESCRIBED IN

SPECIFICATIONS.

3. REMOVE EXISTING FLASHINGS PRIOR TO INSTALLATION OF NEW FLUID APPLIED SYSTEMS.

ROOF DRAIN

PARTIALLY REINFORCED RESTORATION

DECK CLAMP

EXISTING INSULATION SUMP

CAST-IRON DRAIN BOWL

CLAMPING RING

DRAIN STRAINER

LIQUID APPLIED BASE COAT

EXTEND LIQUID APPLIED

SYSTEM INTO DRAIN

N.T.S.

CLEAN TO BRIGHT

METAL AND PRIME

EXISTING ROOF MEMBRANE

TRIM EXISTING FLASHINGS TO

WHERE BOWL TURNS DOWN.

ENSURE NEW FLASHINGS FULLY

ENCAPSULATES OLD FLASHINGS.

CUT REINFORCEMENT INTO TRIANGLES

AND OVERLAP INTO BOWL.

LIQUID APPLIED REINFORCED BASE COAT

AutoCAD SHX Text

2017 TREMCO

AutoCAD SHX Text C

AutoCAD SHX Text R

Sheets and Views