10. E-101 E-HOUSE PLAN.pdf

PDF 376 KB Posted

Attached to
Repair and Construct Primary Electric Distribution
Solicitation number
FA487724B0001
Issued by

About this file

This solicitation package outlines requirements for a primary electric distribution repair and construction project at Davis-Monthan Air Force Base in Arizona. The project scope includes repair, construction, and demolition work to design and construct a new switch house facility. All work must comply with current base design guidelines, engineering manuals, and cybersecurity standards. Bidders must have the ability to bring existing facility systems up to code and provide supervision to complete the project. The solicitation package and 20 accompanying attachments provide a comprehensive overview of solicitation requirements. The submission deadline for Entry Authorization Letters is March 15, 2024 at 1:00 pm local time, and name changes will not be permitted after submission. The Department of the Air Force Air Combat Command is the issuing agency.

View the file

Other files

File Type Posted
Solicitation Amendment FA487724B00010003 SF 30.pdf PDF
Solicitation Amendment - FA487724B00010003.pdf PDF
23. Wage Determination - AZ20240040.pdf PDF
Solicitation - FA487724B0001.pdf PDF
Solicitation Amendment FA487724B00010002 SF 30.pdf PDF
Solicitation - FA487724B0001.pdf PDF
7. DMAFB Electrical Dist - Cx Plan REV 1.pdf PDF
4. 5015-21-3104 DMAFB Substation - 100% Structural Calcs - REV 1.pdf PDF
22. Sign-In Sheet (3-26).pdf PDF
21. FBNV190002 RFI ANSWERS.xlsx XLSX spreadsheet
9. DMAFB Electrical Distribution - Drawing Set - 100 pct - REV 1.pdf PDF
8. DMAFB Electrical Dist - Design Analysis - 100 percent - REV 1.pdf PDF
6. 5015-21-3104 DMAFB Substation Specs - REV 1.pdf PDF
3. 5015-21-3104 DMAFB Substation - 100% Elec Calc Package - REV 1.pdf PDF
Solicitation Amendment FA487724B00010001.pdf PDF
2. 5015-21-3104 DMAFB Cutsheets -100pct - REV 1.pdf PDF
5. 5015-21-3104 DMAFB Substation P&C Report - 100%.pdf PDF
9. DMAFB Electrical Distribution - Drawing Set - 100 pct.pdf PDF
19. Template of Contractor EAL.xlsx XLSX spreadsheet
Solicitation - FA487724B0001.pdf PDF
6. 5015-21-3104 DMAFB Substation Specs 1.19.2024.pdf PDF
7. DMAFB Electrical Dist - Cx Plan.pdf PDF
8. DMAFB Electrical Dist - Design Analysis - 100 percent.pdf PDF
16. Cybersecurity of Facility-Related Control Systems (01-18-2017).pdf PDF
1. Specifications Package FBNV190002.pdf PDF
2. 5015-21-3104 DMAFB Cutsheets -100pct.pdf PDF
3. 5015-21-3104 DMAFB Substation - 100% Elec Calc Package.pdf PDF
13. Contractor Environmental Guide (15 May 2019).pdf PDF
14. DMAFB Design Compatibility Guidelines 2017.pdf PDF
17. AF Form 3052 (Blank) - FBNV190002.xlsx XLSX spreadsheet
20. Section B - Price Fill-In.pdf PDF
4. 5015-21-3104 DMAFB Substation - 100% Structural Calcs.pdf PDF
11. E-601 SINGLE LINE DIAGRAM.pdf PDF
12. DMAFB Installation Failure Action Plan.pdf PDF
15. 355 CS Base Design Guide 2021.pdf PDF
18. AF Form 66 FBNV190002.xlsx XLSX spreadsheet
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LOWER POWER CABLE

GLAND PLATES

PERSONNEL

DOOR

(DOOR B) EQUIPMENT DOOR

(DOOR A)

HV

AC

#1

BATTERY

EXHAUST

FAN

"SS"

PA

NE

LB

OA

RD

FACP

38'-2"

4'-11"

3' 6'

3'- 6"

BATTERY

CHARGER

BATTERY

ENCLOSURE

4'

4' 4'

7'

REAR ACCESS PLATFORM

32'-7"

4'

SCALE:1 1/2" = 1'-0"

ELECTRICAL HOUSE PLAN

F1

F2 F1 F1 F2

X

W

3 3

WP

SS-14

SS-14

W

SS-14

SS-14

X

SS-14

OS OS

SS-14

SS-14 SS-14

SS-14SS-14

SS-14

WP

SS-18

WP

WP

SS-20

SS-20

SS-18

SS-18

SS-18

SS-20

"DC"

PANELBOARD

125VDC

8Y

/12 0V

AC

SS-2

SS-16

SS-7

SS-1

SS-20

HV

AC

#2

SS-10

F1

SS-14

W

SS-14

W

SS-14

WP

SS-18

HYDROGEN

SS-22

MONITOR

EYE WASH

OVERHEAD

H2O TANK

GB

PLATFORM

STAIRSSTAIRS

STAIRS

HEAT

EXHAUST

FAN

60 CFM

150 CFM

150 CFM

EF-2

T

T

40 CFM

PLATFORM

4'

8 8

SE

L-

S

GB

THERMOSTAT

RE

LA

Y

SW

IT

CH

SS-8

EF

-1

"SDNS3"

S O

L I C

I T

A T

I O

N

N

O

F I L E

N

A M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F I

U M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

I S

S U

E

D

A T

E

D A

T E

M A

R K

D E

S C

R I P

T I O

N

C O

N T

R A

C T

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

D A

V I S

M

O N

T H

F B

A

R I Z

O N

A

C I V

I

G

I N

E E

R

O F

F I C

E

O

F

T

H

B

S

E

R E

P A

R

N

S T

R U

T

P

I M

A R

Y

E

L E

C T

R I C

A L

D I S

T R

I B

U T

I O

N

F

A

F

D A

V I S

M

O N

T H

B

T U

C S

O N

P

I M

A

C

O U

N T

Y

A

Z

C O

N S

T R

U C

T I O

N

D

R A

W I N

G S

U.S. AIR FORCE

S

K Y

P

R

K

C

T

S A

N

D

I E

G O

C

A L

I F

O R

N

G

E

O

R G

I

A

R

E

G

I

ST

E

R

E

D

E

N

G

I N E

E

R

No. PE035113

PROFESSIONAL

S

T

E

P

H

. S

A

N

T

I

L

I

A

N

OF

E-

1 E -H

OU

SE

P

LA

N.

dw g

E-

HO

US

E

PL

AN

E-101

SE

S

JV

M

MA

G

PW

M

AS

S

HO

W

N

AR

CH

D

/23

/20

S

EP

T

FA

F0

#KEYED NOTES

1. CONNECT EXTERIOR LIGHT FIXTURE WITH INTEGRAL PHOTOCELL

TYPE TO UNSWITCHED HOT CIRCUIT.

2. PROVIDE BATTERY HANDLING SAFETY SUPPLIES AND EMERGENCY

SPILL KIT.

3. ALL 2 AND 3-PHASE LOW VOLTAGE EQUIPMENT SHALL BE LISTED

FOR 208V OPERATION. CONTRACTOR SHALL NOT SUPPLY OR

INSTALL ANY EQUIPMENT LISTED FOR 240V OPERATION.

4. PROVIDE AND INSTALL EYE WASH STATION WITH 6 GALLON

OVERHEAD H2O TANK. STATION SHALL PROVIDE MINIMUM 0.4

GALLONS OF WATER TO BOTH EYES FOR 15 MINUTES.

5. BATTERY EXHAUST SHALL BE DUCTED TO EXHAUST ALUMINUM

WALL CAP, BASIS OF DESIGN: DAYTON 45PE74. PROVIDE BATTERY

ENCLOSURE WITH BATTERY RACKS FOR 60 CELLS, COMPLETE

WITH DRIP CONTAINMENT, VENTED CABINET WITH 120 VOLT

EXHAUST FAN EF-1 EXHAUSTING 40 CFM.

6. E-HOUSE SHALL BE PROVIDED WITH HANDRAILS AND GUARDRAILS

FOR ELEVATED PLATFORMS AND STAIRS. REFERENCE

STRUCTURAL DRAWING SS301 FOR DETAILS.

7. PROVIIDE AND INSTALL A VISIBLE ALARM INSIDE AND OUTSIDE

THE PERSONNEL DOOR. ALARM SHALL BE TRIGGERED BY THE

HYDROGEN MONITOR

8. PROVIDE AND INSTALL A 4'-0" BOLLARD - SEE DETAIL 3/E502.

9. PROVIDE AND INSTALL SCHWEITZER ENGINEERING LABORATORIES

"SEL-2740S SOFTWARE DEFINED NETWORK SWITCH". CONNECT

ALL E-HOUSE SWITCHGEAR SEL-751 RELAYS INTO THIS NETWORK

SWITCH USING FIBER OPTIC CABLES. CONNECT THE SEL-2740S TO

THE EXISTING SEL PROTECTIVE RELAY SYSTEM IN THE CONTROL

HOUSE WITH A FIBER OPTIC CABLE OVER GOOSE PROTOCOL. THE

2 NEW (51-M2, 51,M3) AND 1 EXISTING (51M) SEL-751 RELAYS IN THE

EXISTING DMAFB SWITCHGEAR WILL SEND TRIP AND LOCKOUT

COMMANDS TO THE E-HOUSE FEEDER BREAKERS IN THE EVENT

OF A FAULT OR ARC FLASH. COORDINATE EXACT SYSTEM

REQUIREMENTS WITH SEL.

POWER CONDITIONS

NORMAL

EMERGENCY

AVG. LEVELS: (FOOT CANDLES) MAX LEVELS: (FOOT CANDLES) MIN LEVELS: (FOOT CANDLES)

52.4 73.9 20

15.8 25.2 7.7

DC SYSTEM NOTES:

1. DC SYSTEM SHALL COMPLY WITH OSHA 1926.441, UFC 3-520-01,

AND UFC 3-520-05.

2. PROVIDE AND INSTALL VALVE REGULATED LEAD ACID (VRLA)

BATTERIES FOR THE E-HOUSE DC SYSTEM. SEE AFPAM 32-1189

FOR VRLA MAINTENANCE AND HANDLING.

3. BATTERIES SHALL PROVIDE 100 AMPS AT 125VDC FOR A MINIMUM

OF 8 HOURS TO THE ENTIRE DC SYSTEM: 60 CELLS, 2V, 800AH.

4. BATTERIES SHALL BE NON-VENTED TYPE.

I S

S U

D

N

S T

R U

C T

I O

N

P W

M

MAG. VAR. 9° 32'E

15 SEP 2022

N

IES RECOMMENDED:

(AVG. FOOT CANDLES)

CONTRACTOR'S SCOPE OF WORK THIS SHEET:

1. CONTRACTOR TO PROVIDE AND INSTALL THE NEW ELEVATED

SUBSTATION E-HOUSE AS SHOWN WITH ELECTRICAL ARC CHUTES AND

COMPLETE WITH ALL FEATURES, EQUIPMENT, CABLES, AND

CONNECTIONS REQUIRED TO PROVIDE A WORKING SYSTEM AS

INTENDED AND DESCRIBED IN THE PROJECT DOCUMENTATION. REFER

TO THE PROJECT ELECTRICAL DRAWINGS, STRUCTURAL DRAWINGS,

COMMISSIONING PLAN, P&C REPORT, AND SPECIFICATIONS FOR A

COMPREHENSIVE LISTING OF LABOR AND MATERIALS TO BE PROVIDED

BY THE GENERAL CONTRACTOR.

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text 1/2"=1'-0"

AutoCAD SHX Text 0'

AutoCAD SHX Text 1'

AutoCAD SHX Text 2'

AutoCAD SHX Text 3'

AutoCAD SHX Text 4'

Sheets and Views
E-101

File details come from the government source that posted it. Updated .