CIP #ST2501 - Cattletrack Road Pedestrian-Drainage Improvements Project Plan Set
This is a comprehensive construction plan set for the Town of Prescott Valley's CIP #ST2501 Cattletrack Road Pedestrian-Drainage Improvements Project, prepared by Lyon Engineering & Surveying, Inc. The project encompasses improvements to Cattletrack Road and Roundup Drive, including the construction of roadway sections, curb and gutter installations, sidewalks and ADA-compliant ramps, storm drainage systems, water infrastructure, fire hydrants, driveway reconstruction, and signage and pavement markings. The project extends approximately 1,950 linear feet along Cattletrack Road from Station 10+00 to Station 28+80, with an additional segment on Roundup Drive. Key quantities include 2,774 cubic yards of earthwork, 1,742 linear feet of curb and gutter, 1,264 square yards of sidewalk, 530 linear feet of storm drain pipe, 244 linear feet of water main installation, and approximately 2,636 square yards of asphalt paving. The plan set contains 28 sheets including removal plans, improvement plans, grading plans, signage and striping plans, and detailed construction specifications with references to Town of Prescott Valley Design and Construction Standards (TDCS), Quad City Standard Details (QCSD), and Maricopa Association of Governments (MAG) standards.
The project is funded through a Federal Community Development Block Grant (CDBG) from the State of Arizona Department of Housing, with Grant #123-25. Design requirements address FEMA floodplain compliance, with the project located in effective FIRM 04025C1714H and subject to specific drainage and grading standards that maintain historical drainage patterns while improving pedestrian safety through ADA-compliant design. Comprehensive utility coordination is required, including identification and protection of existing water, sewer, gas, fiber optic, and overhead power lines. The plans include detailed erosion control measures, sediment wattle installations, and stabilized construction entrance/exit specifications in compliance with Arizona Department of Environmental Quality (ADEQ) requirements and Arizona Pollutant Discharge Elimination System (AZPDES) General Permit standards. All work must comply with applicable municipal, county, state, and federal regulations, with inspection and acceptance responsibilities assigned to the Town's Engineer of Record. A two-year warranty period is required following final project acceptance.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1/30/2026
DATE
DRAWING NUMBER
SHEET
LYON PROJECT #
M O
H A V E
C O
C O
N
IN
O
N A V A
JO
A P A C
H E
Y A V A P A I
M A R
IC
O P A
Y U
M A
G R
E E
N L E
E
P
IN
A L
P
IM
A
CRUZ
SANTA
C
O C
H
IS
E
G R
A H
A M
G
IL
ALA
P
A Z
A
B
C
D
1 2 3 4 5
FILENAME:G:\PROJECTS\523_TOWN_OF_PRESCOTT_VALLEY\523-33 Cattletrack Roadway and Pedestrian\CADD\DGN\PLANSET\Cattletrack-Roundup Sheets.dgn
REUSE OF DOCUMENTS:
SURVEYING, INC. AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF LYON ENGINEERING & SURVEYING, INC.
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF LYON ENGINEERING &
D E
S
IG
N
D R
A W
N
C H
E C
K E
D
A P
P R
O V
E D
VERIFY SCALE
SCALES ACCORDINGLY
THIS SHEET, ADJUST
IF NOT ONE INCH ON
0 20
B A
B
A P
V D
B Y
N O
D A
T E
R E
V
IS
IO
N S
D E
S C
R
IP
T
IO
N
ORIGINAL DRAWING.
BAR IS ONE INCH ON
1"0
B A
B
B A
B
S A
L
G E
N E
R A
L
22"x34" sheets only)
(This scale is valid for
1" = 20 ft, Horizontal
DRAWING SCALE
NOT TO SCALE
ARIZONA REGISTRATION NO.
DATENAME
TITLE
47997
NOT TO SCALE
DATE
BRIAN A. BUCHOLTZ, P.E., CFM
KELL PALGUTA
PROJECT MANAGER
MICHAEL GREER
KENDALL SCHUMACHER
523-33
R eg is te re d Pr ofe ssionalEngineer (C iv il)
AR
IZONA,U.S
.A
D a te
Signed
C
E R
TI
FICATE
N
O
47997
BRIAN A.
BUCHOLTZ
www.lyonengineering.com
(928) 776-1750
Prescott, AZ 86301
Building #2
2971 Willow Creek Road
KYMBERLI LOPEZ
JANELL KIEHL
KEN FREUND
MATT ZURCHER
PUBLIC WORKS DIRECTOR
C
IP
S
T
IM
P
R O
V E
M E
N T S P
R O J E
C T
P E
D E
S T
R
IA
N A
N D D
R A
IN
A G
E
C A
T T
L E
T R
A C
K R
O A
D
JANUARY 2026
JANUARY 2026
G.01
C O
V E
R S
H E
E T
SUBMITTED BY
(928) 308-1902
(928) 443-6794
(928) 776-2510
A
LT
9A
L T
264 264
ALT
(928) 759-3070
PRESCOTT, AZ 86301
1445 MASONRY WAY
CENTURYLINK
NEIL WADSWORTH
MAYOR
TOWN COUNCIL
ACCEPTED BY
(928) 759-3070
PRESCOTT, AZ 86301
6405 WILKINSON DRIVE
UNISOURCE ENERGY SERVICES
PRESCOTT, AZ 86305
3201 TOWER ROAD
SPARKLIGHT
MATT ZURCHER
PRESCOTT VALLEY, AZ 86314
7501 E. SKOOG BOULEVARD
UTILITIES DEPARTMENT
TOWN OF PRESCOTT VALLEY
PRESCOTT VALLEY, AZ 86314
7501 E. SKOOG BOULEVARD
PUBLIC WORKS DEPARTMENT
TOWN OF PRESCOTT VALLEY
PRESCOTT, AZ 86301
6672 CORSAIR AVENUE
ARIZONA PUBLIC SERVICE CO.
(928) 759-9062ETHAN BEYEA
JACOBS
OPERATIONS COMPANY:
UTILITIES CONTRACT
TOWN OF PRESCOTT VALLEY
HEATHER RUDER
(LUMEN)
SAMANTHA MEYER
DESCRIPTIONDWG NO.SHEET NO.
BRIAN A. BUCHOLTZ, P.E.
LESLIE WARD (928) 771-7234
KAYLA SAVAGE
CONTACT TELEPHONECOMPANY
GENERAL NOTES
BENCHMARK
CONTRACTOR CAUTION NOTE
EXTREME CAUTION REGARDING UNIDENTIFIED EXISTING DRY UTILITY LINES AND CONFLICTS.
LINES AND CONFLICTS ARE SHOWN IN THE IMPROVEMENT PLANS. CONTRACTOR TO USE
PROVIDERS TO IDENTIFY EXISTING LOCATIONS AND POTENTIAL CONFLICTS. ALL IDENTIFIED
A THOROUGH ATTEMPT AND COORDINATION HAS BEEN COMPLETED WITH THE DRY UTILITY
OF LYON ENGINEERING & SURVEYING, INC.
EXPIRATION DATE OF THESE PLANS IS AT THE SOLE DISCRETION
ENGINEERS STAMP ON THIS PAGE. ANY EXTENSION TO THE
PURSUANT TO THE STANDARD OF CARE AT THE DATE OF THE
PERMITS EXPIRES. LYON ENGINEERING PRODUCED THESE PLANS
ONE OF THE MUNICIPAL, COUNTY, STATE OR FEDERAL CONSTRUCTION
THE DATE SHOWN ON THE AFFIXED ENGINEERS STAMP OR, IF ANY
SURVEYING, INC. AND ARE NULL AND VOID 2 (TWO) YEARS AFTER
THESE PLANS ARE THE COPYRIGHT OF LYON ENGINEERING &
EXPIRATION DATE:
SR 89
A
GENERAL
EROSION CONTROL
DETAILS
ANTELOPE MEADOWS DR
SR 89
A
FAIN RD
AVE
POWERS
R O
B E
R T R
D
V
IE
W P
O
IN
T D
R
PV UNIT 17
PV UNIT 18
PV UNIT 16
GRANVILLE PV UNIT 15 PV UNIT 9
PRONGHORN
VIEWPOINT
CIP # ST2501
DRAINAGE IMPROVEMENTS PROJECT
CATTLETRACK ROAD PEDESTRIAN AND
PUBLIC WORKS DEPARTMENT
TOWN OF PRESCOTT VALLEY CIVIL
REMOVALS
SIGNAGE & STRIPING
SEE DRAWING SVY.01 FOR BENCHMARK INFORMATION.
Phone: (928) 776-1750
2971 Willow Creek Road, Buiding #2, Prescott, Arizona 86301
UNLESS OTHERWISE SHOWN AS EXISTING.
SHALL BE DEDICATED BY A RECORDED LEGAL DESCRIPTION
ALL EASEMENTS CALLED OUT IN THESE CONSTRUCTION DRAWINGS
UNDERGROUND POWER LINES, GAS MAINS, AND OTHER DRY UTILITIES.
CONTRACTOR IS TO USE EXTREME CAUTION WHEN WORKING NEAR
FEMA FLOOD ZONES X (UNSHADED), X (SHADED), AE, AND AE (FLOODWAY).
LOMR IS CASE NO. 21-09-1015P, DATED 4/6/2022. THE PROJECT IS LOCATED IN
THE EFFECTIVE FEMA FIRM IS 04025C1714H, DATED 8/24/2021. THE EFFECTIVE
RIGHT-OF-WAY PERMITS ARE ALSO REQUIRED PRIOR TO CONSTRUCTION.
TO THE NTP BEING ISSUED. TOWN OF PRESCOTT VALLEY GRADING AND
THE CONTRACTOR TO THE TOWN FOR REVIEW AND APPROVAL PRIOR
A TRAFFIC CONTROL PLAN IS REQUIRED TO BE PROVIDED BY
DRAINAGE STATEMENT
FEMA FLOODPLAIN NOTE
WITHIN THE CORRIDOR.
IS MINIMAL AND SOLELY INTENDED TO IMPROVE PEDESTRIAN SAFETY
CONSTRUCTING THE IMPROVEMENTS AT GRADE. ANY PROPOSED FILL
TO FEMA FOR A CLOMR/LOMR MAP CHANGE. THIS IS ACCOMPLISHED BY
TOWN CODE FLOODPLAIN REGULATIONS AND WITHOUT HAVING TO SUBMIT
PROVIDE A SAFE, ADA-COMPLIANT PATH WHILE COMPLYING WITH THE
THE INTENT OF THE MUP DESIGN (ADJACENT TO ROUNDUP DRIVE) IS TO
CREATING DRAINAGE CONDITIONS BETTER THAN EXISTING.
WILL BE REDUCED DUE TO THE PROPOSED STORM DRAIN SYSTEMS,
OUTLET LOCATIONS ARE UNCHANGED, AND THE SURFACE DRAINAGE
PATTERNS TO THE BEST EXTENT PRACTICAL. THE DRAINAGE
THE INTENT OF THIS DESIGN IS TO MAINTAIN HISTORICAL DRAINAGE
24-26
EC.02
EC.01
D.01-D.03
ST.05
ST.04
ST.03
ST.02
ST.01
C.09
C.08
C.07
C.06
C.05
C.04
C.03
C.02
C.01
R.05
R.04
R.03
R.02
R.01
G.04
G.03
G.02
G.01
EROSION CONTROL DETAILS
EROSION CONTROL PLAN
DETAILS 1-3
CATTLETRACK ROAD STA.23+80 TO 28+80 SIGNAGE & STRIPING PLAN
CATTLETRACK ROAD STA.19+00 TO 23+80 SIGNAGE & STRIPING PLAN
CATTLETRACK ROAD STA.14+20 TO 19+00 SIGNAGE & STRIPING PLAN
CATTLETRACK ROAD STA.10+00 TO 14+20 SIGNAGE & STRIPING PLAN
ROUNDUP DRIVE STA.10+00 TO END SIGNAGE & STRIPING PLAN
CATTLETRACK ROAD STA.23+80 TO 28+80 DRIVEWAYS GRADING PLAN
CATTLETRACK ROAD STA.19+00 TO 23+80 DRIVEWAYS GRADING PLAN
CATTLETRACK ROAD STA.14+20 TO 19+00 DRIVEWAYS GRADING PLAN
CATTLETRACK ROAD STA.10+00 TO 14+20 DRIVEWAYS GRADING PLAN
CATTLETRACK ROAD STA.23+80 TO 28+80 IMPROVEMENT PLAN
CATTLETRACK ROAD STA.19+00 TO 23+80 IMPROVEMENT PLAN
CATTLETRACK ROAD STA.14+20 TO 19+00 IMPROVEMENT PLAN
CATTLETRACK ROAD STA.10+00 TO 14+20 IMPROVEMENT PLAN
ROUNDUP DRIVE STA.10+00 TO END IMPROVEMENT PLAN
CATTLETRACK ROAD STA.23+80 TO 28+80 REMOVALS PLAN
CATTLETRACK ROAD STA.19+00 TO 23+80 REMOVALS PLAN
CATTLETRACK ROAD STA.14+20 TO 19+00 REMOVALS PLAN
CATTLETRACK ROAD STA.10+00 TO 14+20 REMOVALS PLAN
ROUNDUP DRIVE STA.10+00 TO END REMOVALS PLAN
SURVEY CONTROL MAP
ABBREVIATION AND SYMBOL LEGEND, PROJECT QUANTITIES
GENERAL NOTES
COVER SHEET
VICINITY MAP
PROJECT
UTILITY INFORMATION
LOCATION MAP
PROJECT
SHEET INDEX
E
L
EST. 1995
.C
NI
G N I
Y E
V R
U S
& GNI
R
E
E N I
G N
E N
O
YL
working days before you begin excavation
Contact Arizona 811 at least two full
Call 811 or click Arizona811.com
DRAWING NUMBER
SHEET
LYON PROJECT #
A
B
C
D
1 2 3 4 5
FILENAME:G:\PROJECTS\523_TOWN_OF_PRESCOTT_VALLEY\523-33 Cattletrack Roadway and Pedestrian\CADD\DGN\PLANSET\Cattletrack-Roundup Sheets.dgn
REUSE OF DOCUMENTS:
SURVEYING, INC. AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF LYON ENGINEERING & SURVEYING, INC.
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF LYON ENGINEERING &
D E
S
IG
N
D R
A W
N
C H
E C
K E
D
A P
P R
O V
E D
VERIFY SCALE
SCALES ACCORDINGLY
THIS SHEET, ADJUST
IF NOT ONE INCH ON
0 20
B A
B
A P
V D
B Y
N O
D A
T E
R E
V
IS
IO
N S
D E
S C
R
IP
T
IO
N
ORIGINAL DRAWING.
BAR IS ONE INCH ON
1"0
B A
B
B A
B
S A
L
G E
N E
R A
L
22"x34" sheets only)
(This scale is valid for
1" = 20 ft, Horizontal
DRAWING SCALE
523-33
R eg is te re d Pr ofe ssionalEngineer (C iv il)
AR
IZONA,U.S
.A
D a te
Signed
C
E R
TI
FICATE
N
O
47997
BRIAN A.
BUCHOLTZ
www.lyonengineering.com
(928) 776-1750
Prescott, AZ 86301
Building #2
2971 Willow Creek Road
C
IP
S
T
IM
P
R O
V E
M E
N T S P
R O J E
C T
P E
D E
S T
R
IA
N A
N D D
R A
IN
A G
E
C A
T T
L E
T R
A C
K R
O A
D
JANUARY 2026
G.02
G E
N E
R A
L N
O T
E S
21.
20.
19.
18.
17.
16.
15.
14.
13.
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
EXPENSE.
AS A RESULT OF THE CONSTRUCTION AT THE CONTRACTOR'S
PAVEMENT MARKINGS AND RECESSED PAVEMENT MARKERS DAMAGED
EXCEPT WHERE NOTED OTHERWISE, AND SHALL REPLACE ANY
MARKINGS AND RECESSED PAVEMENT MARKERS THAT ARE TO REMAIN,
THE CONTRACTOR SHALL PRESERVE ALL EXISTING PAVEMENT
DIRECTED BY THE ENGINEER.
FOOT (1'-0") CLEAR OF THE CONSTRUCTION JOINT, UNLESS OTHERWISE
SURFACECOURSE IS PLACED SO THAT THE STRIPING IS OFFSET ONE
IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE FINAL
TWO INCHES FROM THE NEAREST EDGE OF THE STRIPING.
STRIPING, THE NEAREST EDGE OF EACH MARKER SHALL BE OFFSET
WHERE RECESSED PAVEMENT MARKERS ARE PLACED ALONG SOLID
THE ENGINEER.
COMPLETION OF THE FINAL PAVEMENT SURFACE, OR AS DIRECTED BY
RECESSED PAVEMENT MARKERS SHALL BE INSTALLED 30 DAYS AFTER
INSTALLED PER ADOT STD. DWG. M-18.
APPROACHING TRAFFIC. RECESSED PAVEMENT MARKERS SHALL BE
SO THAT THE RED FACE OF EACH MARKER IS FACING AWAY FROM
FLOW. TYPE C AND TYPE E PAVEMENT MAKERS SHALL BE INSTALLED
TRAFFIC AND IS PERPENDICULAR TO THE DIRECTION OF TRAFFIC
THE REFLECTIVE FACE OF EACH MARKER IS FACING THE DIRECTION OF
ALL RECESSED PAVEMENT MARKERS SHALL BE INSTALLED SO THAT
WHICH IS ON THE ADOT APPROVED PRODUCTS LIST.
DWG. M-19. THEY SHALL BE INSTALLED WITH A BITUMINOUS ADHESIVE
REFLECTORS AND SHALL CONFORM TO THE DETAILS OF ADOT STD.
ABRASION-RESISTANT COATINGON THE FACE OF THE PRISMATIC
ALL RECESSED PAVEMENT MARKERS SHALL HAVE AN
DOES NOT CONSTITUTE STRIPE OBLITERATION.
ACCOMPLISHED BY APPROVED METHODS. PAINTING OVER STRIPING
WHEN STRIPE OBLITERATION IS NECESSARY, IT SHALL BE
FOR PAINTED BULL NOSES, SEE ADOT STD. DWG. M-1.
INSTALLED IN ACCORDANCE WITH ADOT STD. DWG M-11.
OF ADOT STD. DWG. M-10 LEGENDS AND PAVEMENT ARROWS SHALL BE
LEGENDS AND PAVEMENTS ARROWS SHALL CONFORM TO THE DETAILS
DIRECTED BY THE ENGINEER.
THE PERMANENT PAVEMENT MARKING PLANS MAY BE MODIFIED AS
LAYOUT SHALL BE APPROVED BY THE ENGINEER PRIOR TO STRIPING.
MORE THAN 50 FEET APART ALONG THE LINES TO BE STRIPED. THE
COURSE FOLLOWING CONTROL POINTS THAT HAVE BEEN SET NO
INSTALLATION OF PERMANENT MARKINGS ON THE FINAL SURFACE
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LAYOUT AND
OF THE ADOT STANDARD SPECIFICATIONS.
(0.090") EXTRUDED TERMOPLASTIC IN ACCORDANCE WITH SECTION 704
ALL FINAL STRIPING OF YIELD LINES AND STOP BARS SHALL BE 90 MIL
SAME TIME.
BY THE ENGINEER. ALL OTHER MARKINGS SHALL BE APPLIED AT THE
AFTER COMPLETION OF THE FINAL PAVEMENT SURFACE, AS DIRECTED
SPECIFICATIONS PLACED OVER NEW PAVEMENT 30 CALENDAR DAYS
ACCORDANCE WITH SECTION 709 OF THE ADOT STANDARD
THE FINAL STRIPING SHALL BE DUAL COMPONENT (EPOXY) MARKING IN
ADOT STANDARD SPECIFICATIONS.
PAVEMENT MARKING TAPE IN ACCORDANCE WITH SECTION 705 OF THE
ALL LEGENDS AND PAVEMENT ARROWS SHALL BE TYPE I PREFORMED
EXISTING STOP BAR.
BAR ON THE SAME DAY THE FINAL SURFACE COURSE COVERS AN
STANDARD REFLECTORIZED TRAFFIC PAINT AS A TEMPORARY STOP
THE CONTRACTOR SHALL APPLY ONE APPLICATION OF WHITE
PAINT.
INTERIM STRIPING AND ARROWS SHALL BE 15 MIL (0.015 INCH) THICK
STRIPING.
PAVEMENT SURFACE AND MAINTAINED UNTIL APPLICATION OF FINAL
ROADWAY SURFACE AFTER THE INSTALLATION OF THE FINAL
SPECIFICATIONS. THE STRIPING SHALL BE INSTALLED ON THE
ACCORDANCE WITH SECTION 708 OF THE ADOT STANDARD
THE INTERIM STRIPING SHALL BE PAVEMENT MARKING PAINT IN
PLACEMENT OF TYPE I PAVEMENT MARKINGS.
PAVEMENT TEMPERATURES SHALL NOT BE LESS THAN 60°FOR THE
PLACEMENT OF DUAL COMPONENT (EPOXY) STRIPING. THE AIR AND
PAVEMENT TEMPERATURES SHALL NOT BE LESS THAN 40°FOR THE
MARKINGS, THE ROADWAY SURFACE SHALL BE DRY AND THE AIR AND
BLOWING. IMMEDIATELY PRIOR TO THE PLACEMENT OF ALL PAVEMENT
SATISFACTION OF THE ENGINEER, BY SWEEPING AND AIR-JET
THE CONTRACTOR SHALL CLEAN THE ROADWAY SURFACE TO THE
EDGE OF PAVEMENT, UNLESS OTHERWISE NOTED.
CENTER OF THE DOUBLE STRIPING AND ARE TO THE FACE OF CURB OR
OF THE STRIPING OR IN THE CASE OF DOUBLE STRIPING TO THE
THE DIMENSIONS SHOWN TO PAVEMENT MARKING ARE TO THE CENTER
DETAIL WHEN INSTALLING PAVEMENT MARKINGS AND MARKERS.
TO SCALE. THE CONTRACTOR SHALL FOLLOW ALL DIMENSIONS AND
THE PAVEMENT MARKING DRAWINGS ARE SCHEMATIC ONLY AND NOT
INCLUDING THE ARIZONA SUPPLEMENT.
MANUAL ON THE UNIFORM TRAFFIC CONTROL DEVICES (MUTCD)
MARKING STANDARD DRAWINGS AND THE 2009 EDITION OF THE
ALL STRIPING SHALL BE IN COMPLIANCE WITH THE ADOT SIGNING AND
DESCRIPTION OBSERVED SAG CORRECTION ACTION REQUIRED
8" to 12" Dia. Pipe
8" to 12" Dia. Pipe
12" to 24" Dia. Pipe
12" to 24" Dia. Pipe
Greater than 24" Dia. Pipe exiting manhole
Pipe entering or
Less than or equal to ½" than or equal to 1"
Greater than ½" but less
Less than or equal to 1" than or equal to 1 ½"
Greater than 1" but less
Greater than 1 ½"
Any Yes
Yes than 6 occurrences in 100'
Yes if longer than 20' or more
None
None than 3 occurrences in 100'
Yes if longer than 10' or more storm water.
grow within, on or over any drainage easement which would obstruct or divert the flow of
No structure of any kind shall be constructed and/or any vegetation planted or allowed to
Easements 201.4 construction.
from the property owner giving permission for said disposal prior to starting on-site
The grading contractor shall designate a location for wasting spoil materials and a letter
On Site Materials 201.3 prior to project final acceptance.
The Town will review the EOR supplied report to determine if the product is acceptable
-Submit a report to the Town with regard to disposition.
-Review all documentation and findings for compliance with Town Standards with
-Determine if the required procedures and subsequent documentation were complied
The EOR shall:
shall receive copies of applicable documentation for review.
TV inspection of storm drainage infrastructure per applicable QCSD. The Town and EOR
Prior to final acceptance, the contractor shall be responsible for cleaning, visual and/or
Inspections 201.2
-A separate permit is required for any off site grading.
-An on-site grading permit is required.
The following apply:
Permits 201.1
TOWN OF PRESCOTT VALLEY - GRADING & DRAINAGE NOTES
street, sidewalk, right-of-way or easement; or within 50’ of any drainage way.
No construction material, including portable toilets shall be stored on any portion of any
Portable Toilets 103.38 replaced in like kind at the expense of the contractor.
to remain or are not part of this project, and are damaged during construction, will be
All existing landscape including trees, shrubs and irrigation systems that are designated
Landscape 103.37 issuance of a building “Certificate of Occupancy”.
“As-Built” drawings, certified by the EOR, shall be submitted and approved prior to
As-Built 103.36 violation of the Municipal Code, punishable by fine and/or imprisonment.
of construction. The unlawful removal of water from a fire hydrant or any other source is a and testing of waterlines. The meter should be ordered 2 working days prior to the start
The contractor must request a hydrant meter from the Town for site construction, filling
Construction Water 103.35
TDCS.
these plans shall be presented to the EOR for clarification in concordance with the
These plans are subject to interpretation of intent by the EOR. All questions regarding
Plan Interpretation 103.34 therein, actual or relative.
exist. No claim shall be made against the Town or EOR for any excess or deficiency quantities, requirements of work and deficiencies in earthwork quantities should they contractor shall thoroughly satisfy himself as to the actual conditions, earthwork responsibility to conform to all Town requirements. Prior to bidding the work, the of these plans shall in no way relieve the developer, EOR or the contractor from their
Failure of the Town to detect deficiencies or discrepancies in the design or construction
Deficiencies or Discrepancies 103.33 of Prescott Valley.
protect them, will be the contractor’s responsibility to correct at no expense to the Town resulting from failure to adequately locate utilities, and take necessary precautions to the contractor and shall be verified as deemed necessary by the contractor. Damage shown on these plans. Field verification by the contractor will be the sole responsibility of
The EOR will not guarantee any elevations or locations of existing underground utilities
Existing Utilities 103.32 failure to carry out the work in accordance with the contract documents.
with the work. Neither the Town nor the EOR will be responsible for the contractor’s connection techniques, sequences, procedures, safety precautions or programs utilized in
Neither the Town nor the EOR will be responsible for construction means, methods, Means and Methods 103.31 any subcontractor.
construed to create, any contractual relationship between the EOR and the contractor or
Nothing contained in the construction contract documents shall create, nor shall be
Construction Contract 103.30 complete work.
during construction to comply with the construction schedule, and specifications to
The contractor shall provide sufficient personnel and equipment on the job at all times
Construction Schedule 103.29 of any construction to schedule staking.
Contractor shall notify the EOR and/or surveyor two working days (48 hours) in advance
-Notifications 103.28 plans.
contractor shall notify the EOR. The Town does not warrant any quantities shown on the by these plans. If any discrepancies in quantities or site conditions are found, the actual quantities and site conditions prior to bidding the work for the construction covered and may be subject to errors and omissions. Contractors shall satisfy themselves as to
Quantities and site conditions depicted in these plans are for informational purposes only
Project Quantities 103.27 project specifications.
warranty work shall also conform to all portions of the applicable TDCS, QCSD and from the date of Town final acceptance of project. All two (2) yearslasts for a minimum of to restore a project to acceptance criteria as defined by the plan. The warranty period warranty includes any workmanship, labor, materials, equipment, sales tax, etc. required project that will be given to the public per agreement(s). The Town’s definition of a The contractor and/or developer shall provide a warranty for any public project or any
Warranty 103.26 performed at the sole expense of the responsible contractor or subcontractor.
verified as to their origin, any remedial work required to correct any item shall be origin. If, in the opinion of the EOR, the stakes are not maintained intact and cannot be stakes set by the EOR or surveyor are maintained intact and can be verified as to their the inaccuracy of construction stakes set forth by the EOR or surveyor, unless all survey
The contractor shall make no claim against the owner, the EOR or surveyor regarding
Construction Staking 103.25 if construction has not started unless otherwise approved by the Town.
All plans signed/approved by the Town are null and void one year from date of signature
Plan Expiration 103.24
Town prior to acceptance by the Town.
inspection only. The EOR shall provide all certifications and other documentation to the
Arizona, the Town and shall be certified by the EOR. The Town will complete oversight conference. Inspection must meet all requirements set forth by ADEQ, the State of
State of Arizona. The degree of inspection will be determined at the pre- construction
Inspection shall be performed by a qualified representative of an engineer licensed in the
Inspections-103.23 agreements are subject to removal and replacement at no expense to the Town.
All work and materials which do not conform to the required standards, codes and
Defective Materials 103.22
QCSD.
and 8 inches above finished grade upon completion of related construction per applicable
All frames, covers, and valve boxes outside a paved surface shall be adjusted between 6 to finished grade upon completion of paving or related construction per applicable QCSD.
All frames, covers, valve boxes, and manholes inside the paved surface shall be adjusted
Utility Adjustments 103.21
Town will not recognize the validity of said tests.
Pre-completion tests are allowed, if the contractor desires such activity, but the . complete accepted unless testing occurs after all underground disturbances and construction is
Water, gravity sewer, forced sewer, reclaimed water and storm line testing shall not be
Utility Testing 103.20
.applicable QCSD
Service lines must include electronic ball markers per MAG and detectable tape per
Electronic Ball Markers 631.21 saddles allowed.
Service taps and service lines on new construction shall utilize manufactured fittings; no
Fittings 631.20 prior to final permanent attachment of the saddle.
that no ledge or protrusions catch wastewater. All taps shall be inspected by the Town shall have smooth rounded edges and be the same size as the service connection such applicable MAG and QCSD. For service lines installed on existing mains, the drilled hole
All service lines shall have a separate tap to the main and be in accordance with the
Sewer Connections and Taps 631.19
QCSD.
are noted per applicable
Shield mic a liquid antibacterial additive. Specifics concerning Con
Shield mic
New or replacement manholes and appurtenances shall be constructed with Con
Shield mic
Con631.18
Pesticide, or approved equal, per pesticide manufacturer’s instructions.
All new, replacement or refurbished manholes shall be coated with Insecta ® Contact
Roach Control -631.17
No sewer service taps will be allowed into a manhole.
-Manhole Taps 631.16 agreed on before work continues.
EOR and the Town must be notified and a resolution acceptable to all parties must be
If groundwater or other unsuitable conditions are encountered during construction, the
-Groundwater 631.15 supplied report to determine if the product is acceptable prior to project release.
Submit a report to the Town with regard to disposition. The Town will review the EOR 3.
Review the documentation and findings for compliance with Town Standards2.
with
Determine if the required procedures and subsequent documentation were complied 1.
review. The EOR shall:
accepted. The Town and EOR shall receive copies of applicable documentation for
Videos submitted without lateral inspection or 360 degree joint inspection shall not be mainline and service laterals. All joints shall require a full 360 degree camera inspection.
inspection of sewer infrastructure per applicable QCSD. TV inspection shall include both
Prior to final acceptance, the contractor shall be responsible for cleaning and TV
-Cleaning and TV Inspection 631.14 vacuum / low pressure air testing requirements.
No paving, road-base, cover, etc shall occur until sewer infrastructure meets SAG and
Paving Restrictions -631.13
Table 1 - Corrective Action Requirements for SAG for SAG.
Allowable sewer line sag (SAG) is specified per Table 1 - Corrective Action Requirements
Sewer Line Sag 631.12 regulations.
Sewer manhole construction shall be in accordance per applicable QCSD and AAC
Manhole Construction 631.11
PVC sewer pipe and fittings shall be installed pursuant to ASTM standards.
-ASTM 631.10
Trace wire, continuity test and detectable tape required per applicable QCSD.
-Trace Wire 631.9
DIP must be used for bury depth greater than 10 feet.
-Bury Depth 631.8 recommendations.
Sewer line deflection tests shall be done on all PVC lines according to manufacturer’s Deflection Tests -631.7 accordance with applicable QCSD.
Sewer manhole vacuum testing is required on all new or replacement manholes in
-Vacuum Tests 631.6 for Testing and Materials (ASTM) Standards.
Sewer line low pressure air tests shall be done on all lines pursuant to American Society
Air Tests -631.5 applicable QCSDs for guidance.
At locations where water/sewer/reclaimed utilities cross, reference AAC and any
-Crossings 631.4 accordance per applicable QCSD.
Water, reclaimed water, and sanitary sewer separation / protection shall be in
-Separation 631.3
Utility clearances shall be maintained in accordance per applicable QCSD.
Clearance -631.2 reviewer (Yavapai County).
latest revision, must be on plans that will be approved by ADEQ or their delegated
ADEQ requirements must be complied with. A specific note referencing AAC R18-5- 502, -ADEQ 631.1
TOWN OF PRESCOTT VALLEY - SEWER CONSTRUCTION NOTES
out, 2 inch operating nut and open counter-clockwise.
resilient seat, non-rising stem, mechanical joint, fuse bonded epoxy coated inside and
Wedge Gate Valve or an approved equal. Valves shall be new, gate type, bonded
Wedge Gate Valve Series 2639-2640 or American Flow Control Series 2500 Resilient
Valves shall be Mueller 2360 Series Resilient Wedge Gate Valve, Clow Resilient 2.
MAG detail. Handles shall be colored based on AWWA code.
Valve boxes shall comply per applicable QCSD and be fitted with a Debris Cap per 1.
Water Isolation Valves 601.19 and disinfection testing.
observed by the Engineer of Record including but not limited to microbiological, pressure
Per AAC R18-5-508, all quality control testing shall be performed by the Contractor and
Testing 601.18
Backflow Prevention requirements are noted per AAC, Town code and applicable QCSD.
Backflow 601.17 main.
Domestic and fire lines to a structure must be separately tapped to the water distribution
-Separate Tap 601.16 property’s plumbing supply.
property, out of easement, downstream of the meter and prior to branching / entry to the private property and shall be maintained by the owner. It shall be located on private pressure in the public main is 80 psi or higher. Valves / regulators are considered as
A Pressure Reducing Valve / Pressure Regulator is required for all domestic services if
-Pressure Reducing Valve 601.15
ENGINEER'S PAVEMENT MARKING GENERAL NOTES
BRIAN A. BUCHOLTZ, P.E.
adjacent pavement or curb.
immediately adjacent to paved surfaces or curbs shall be the same height as the curb shall be at least 3 inches above any finished grade within 3 feet of the box. Boxes
All water meter boxes not surrounded by or immediately adjacent to paved surface or
Water Meters - 601.14 placed in easement or ROW per applicable QCSD.
the discharge/customer side of the setter (tailstock) are public facilities and must be
Waterline services up to and including the meter, meter box and the transition fitting on
Waterline Services 601.13 applicable QCSD.
Approved backflow protection has been installed if required per Town code and 6.
will result in damage and/or tampering fee per Town Customer Accounts Regulations.
ground within 5 feet shall occur. Any disturbance to the meter, meter box or line setter no disturbance of the meter, line setter, box or , Once the water meter has been set5.
inspection.
structure must extend a minimum of 5 feet away from the meter in order to receive the through the building permit process. The water service line between the meter and the
Water meter boxes and line setters must receive a building inspection approval 4.
Water meter and water service request fees must be paid.3.
the EOR and Town.
New subdivisions: Water infrastructure must have been inspected and approved by 2.
EOR that states that an ATO is not required.
New subdivisions: ATO or ADEQ documentation submitted to the Town from the 1.
been met:
A water meter shall be approved for installation only after the following conditions have
-Water Meter Installation 601.12
Existing system valves shall be operated by Town authorized personnel only.
-Valve Operation 601.11
QCSD.
Operations Company. Contractor is responsible for trenching / clearance per applicable
Hot taps are an exclusive function of the Town and performed by the Town’s Contract -Hot Tap 601.10 accordance per applicable QCSD.
Removal or replacement of existing Asbestos Cement Pipe (ACP) shall be in
-Asbestos Cement Pipe 601.9
Trace wire, continuity test, and detectable tape required per applicable QCSD.
-Trace Wire 601.8 elevation/highest pressure point in the main, whichever is greater.
in the pipe whichever is greater. The working pressure will be based on the lowest
However, test pressure shall be a minimum of 200 psi or 150% of the working pressure accordance with MAG and American Water Works Association (AWWA) standards.
Water mains and appurtenances shall be subject to a pressure and leakage test in
-Pressure and Leakage Test 601.7
.Discharge in accordance with AZPDES regulations3.
appurtenance.
System flushing shall be conducted from the nearest fire hydrant, BOA, or similar 2.
valves, flex couplings, pipe segments or other infrastructure just prior to their installation.
Hypochlorite Free Chlorine solution must be applied to all interior surfaces including
Swabbing of all components is required. A 25 Parts per Million (PPM) Sodium 1.
8 shall be disinfected and flushed as follows:
Disinfection and testing of components not applicable to ADEQ Engineering Bulletin No.
Disinfection -601.6 required by AAC.
Sanitation Foundation (NSF) Standard 61 and bear the ANSI / NSF Standard 61 seal as
All components that come into contact with potable water will meet ANSI / National
-ANSI / NSF 601.5
contractor.
interruption. Shutdowns shall be coordinated with the Town and its water operations of the Town and a minimum of 48 hours’ notice is required prior to any service existing service. No service interruption shall last longer than 4 hours without approval am, Monday thru Thursday, excluding holidays, for any new waterline that will affect
The contractor shall be required to install a connection at night between 10 pm and 5
-Connections 601.4
Town.
MAG/QCSD. Concrete encasement of water lines is not allowed unless approved by the
Water and sanitary sewer separation / protection shall be in accordance per applicable
-Separation 601.3
Utility clearances shall be maintained in accordance per applicable MAG/QCSD.
Clearance -601.2 approved by ADEQ or their delegated reviewer (Yavapai County).
specific note referencing AAC R18-5-502, latest revision, must be on plans that will be standards. Town standards may impose additional or more strict requirements. A
ADEQ requirements must be complied with for all aspects of construction as minimum
ADEQ Requirements -601.1
TOWN OF PRESCOTT VALLEY - WATER CONSTRUCTION NOTES
shall meet approval prior to construction per Section 103.8.
A Traffic Control Plan shall be submitted to the Town’s Traffic Engineer. Traffic Control Traffic Control 301.6 inspected and accepted by the Town.
No chip seal operation shall be considered complete or acceptable for payment until G.
and applied at a rate of 0.10 gal/sy, or as directed by EOR.
to be used for fog seal coat shall be SS-1H, CSS-1H, or CQC-1H, diluted at a 1:1 ratio, Fog seal coat shall be applied to chip seal after sweeping is completed. The material F.
seal operations begin.
threat of rain. The ambient temperature must be 70 degrees F and rising before chip
Chip seal shall be placed only when the roadway surface is dry and there is no E.
th and May 30 st
No chip seal construction will be allowed between September 1D.
QCSD.
placement of surface course and prior to chip seal by the contractor per applicable from chip seal operations and shall be adjusted to finished asphalt or curb grades after
All survey monuments, boxes, manholes, frames, valve, lids, etc. shall be protected C.
without curbs upon approval of the Town.
pickup broom to remove excess chips. Use of a kick broom is acceptable on streets
All streets shall be swept the same day as application. Curbed streets require a B.
lbs/sy.
Chip Seal” using CRS-2P spread at 0.40 gal/sy with 3/8 inch Low Volume Chip at 25 -For Local, commercial and residential streets, chip seal shall be “Low Volume Single two or approved equal spread at 0.50 gal/sy with ½ inch High Volume chip at 32 lbs/sy.
using modified asphalt binder containing crumb rubber, polymer or combination of the
-For Arterial and Collector streets, chip seal shall be “High Volume Single Chip Seal” Pavement shall include a Chip Seal Coat installed per MAG and the following:A.
Chip Seal 301.5 construction.
specification is approved by the Town. Mix design shall be submitted prior to start of
All AC shall be per applicable MAG Specifications or identified by EOR, unless another
Asphalt Concrete 301.4 work within the roadway prism are completed and tested.
No ABC placement or paving construction shall be started until all underground utilities
Utility Work 301.3 inspected and accepted by the EOR.
Base course shall not be placed on subgrade until subgrade requirements have been
Subgrade Inspection 301.2 dirt and debris.
medians, sidewalks and any other impacted ROW areas have been swept clean of all
No project will be considered ready for final acceptance until all curb, roadways, Sweeping 301.1
TOWN OF PRESCOTT VALLEY - TRANSPORTATION NOTES
3070) at least two working days (48 hours) in advance of construction for inspection.
The contractor shall notify the EOR and Town Public Works Department (928-759-
Inspections 103.19 incurred during any construction operations.
The contractor is responsible for repairing damage to existing utilities and/or facilities
Utility Repairs 103.18
.as determined by the Town, completed contractor shall make all necessary repairs and additional video inspection shall be manholes beyond all construction activity. If evidence of debris or damage is found, video inspection shall occur from the next adjacent upstream and downstream section is defined as less than a 2 foot horizontal separation from new construction. The complete a pre and post DVD video inspection per applicable QCSD. Adjacent in this
For any construction adjacent to or crossing existing sewer lines, the contractor shall
Sewer Inspections 103.17 accordance per applicable QCSD.
Maintenance, repair or replacement of existing Asbestos Cement Pipe shall be in
Asbestos Cement Pipe 103.16 shall be in accordance per applicable QCSD for Abandoned Utilities.
Abandonment in place of public utility lines shall be at the discretion of the Town and
Utility Abandonment 103.15 contractor shall contact the owner’s agent for coordination.
from same. Should any location or elevation differ from that shown on these plans, the and/or owner will not guarantee any locations as shown on these plans or those omitted commencement of construction. Dial 8-1-1 or 1-800-STAKE-IT (782-5348). The EOR contractor shall contact Arizona Blue Stake two full working days (48 hours) prior to contractor shall observe all possible precautions to avoid any damage to such. The
Blue Stake locating services must be performed in advance of any construction and
Blue Stake 103.14
-Excavation of areas to determine conflicts with other utilities or infrastructure, etc.
alignment, etc.
-Excavation of areas for new infrastructure to ensure location, size, fittings, depth, etc.
-Excavation of existing infrastructure to ensure location, size, fittings, depth, alignment, accordance with Arizona Administrative Code (AAC) regulations. This includes:
Contractors are responsible for verifying all utilities and underground conflicts in
Utility Conflicts 103.13 contractor.
-Expenses related to excavation and spoil services are the responsibility of the compromised.
a work shift if they inhibit conveyance or if safety within the project limits would be
-Spoils must also be cleared from roadways, pathways, open ground, etc. at the end of materials, debris, etc. generated by a project and any associated costs.
-The removal, transport, permitting, disposal, etc. of any excess vegetation, spoils, limited to:
Contractor is responsible for all project generated excess. This includes, but is not
Excess Materials 103.12
The contractor shall barricade the construction site when the site is unattended.
security measures, must be utilized to ensure safe passage over or around all hazards.
depressions, etc. are not left exposed at the end of a work shift. Traffic plates, or other
The contractor is responsible for ensuring that construction trenches, holes, Site Safety 103.11 minimum of 50’ from any drainage way or drainage inlet.
Appropriately sized covered waste receptacles shall be provided onsite and stored a construction. The site shall at all times remain free of loose trash and debris.
free of debris, construction materials, etc during construction and at completion of
The contractor shall keep all roadway pavement, curb and gutter, and sidewalk surfaces
Site Cleanliness 103.10 including the Town at no expense to the Town.
and dust control, and shall control dust as directed by the appropriate agencies, The contractor shall keep suitable equipment on hand at the job site for maintenance
Dust Control 103.9 contractor will modify the traffic control plan at no expense to the Town.
may require modification of an approved plan based on Town analysis. If so, the until Town approval of the plan is granted. The dynamic nature of traffic related activities
(excluding holidays) prior to commencement of construction. Construction cannot begin perform construction activities. Submittal shall be made at least five Town working days
Contractor is responsible for submitting a traffic control plan to the Town as needed to
Traffic Control Plan 103.8 removal and/or replacement at no expense to the Town.
pre-construction conference. Any work not based on approved revisions is subject to require formal approval by Town engineering staff shall be discussed during the field or at the discretion of the EOR in consultation with the Town versus those which the Town prior to construction. Decisions regarding changes which can be made in the
All revisions to original plans must be approved by the Engineer of Record (EOR) and
Plan Revisions 103.7
.Any quantities shown on plans are not verified by the Town
Quantities 103.6 for all construction within public ROW and easements.
Right-of-Way (ROW) permit and Traffic Control Plan per Section 103.8 will be required construction extending beyond the construction site property boundary. A Town complete all work covered by these plans. A separate permit will be required for any
The owner is responsible for obtaining and complying with all permits required to
Permits 103.5 and/or prior to the next rain event. The amended plan shall be maintained on- site.
from the site, immediate efforts shall be made to correct the problem within 72 hours determined that current controls are not effective at minimizing pollutant discharges become evident during construction, routine inspections, and/or periods of rainfall. If it is necessary during the course of construction to resolve any problem areas, which operational control. The SWPPP and any erosion control plans shall be amended as the owner, developer, general contractor or individual contractor responsible for of the construction site according to guidelines set forth by ADEQ. The Operator can be of the TDCS shall be submitted by the Operator Section 209 The SWPPP required per
SWPPP 103.4
submitted to ADEQ.
The Town shall receive notification and copies when the NOI and NOT have been has been successfully re-vegetated following project completion.
-A Notice of Termination (NOT) shall be submitted to ADEQ once 70% of disturbed land
-A Notice of Intent (NOI) must be submitted to ADEQ that references the SWPPP.
should be in book/binder form.
Town for review. This should include a list of Best Management Practices (BMPs) and involve disturbance of an area that is more than 1 acre and shall be submitted to the
Pollutant Discharge Elimination System General Permit (AZPDES) for all projects that
-A Storm Water Pollution Prevention Plan (SWPPP) is required under The Arizona be complied with:
The following Arizona Department of Environmental Quality (ADEQ) requirements shall
Environmental Controls -103.3
Business License.
construction covered by these plans and possess a current Town of Prescott Valley
-Comply with all local, county, state, and federal laws and regulations applicable to the
The contractor must:
Laws & Licenses 103.2
-Other Standards Listed In The TDCS.
-Maricopa Association of Governments (MAG) Standards
-Quad City Standard Detail (QCSD)
-Town Code
-Specific Development Agreements
-The Town Design and Construction Standards (TDCS) with the latest revision and supplements to:
All work to complete the construction covered by these plans shall be in accordance
Standard Documents 103.1
TOWN OF PRESCOTT VALLEY - GENERAL CONSTRUCTION NOTES
CONTRACTOR TO NOTIFY USPS OF MAILBOX RELOCATIONS.
COORDINATE RELOCATIONS IF CONFLICTS ARE ENCOUNTERED.
OF THE EXISTING WATERLINES. THE CONTRACTOR SHALL BLUE STAKE AND
A BEST EFFORT WAS MADE TO POTHOLE AND DETERMINE THE BURY DEPTH
PROTECTION IF WARRANTED.
AFTER MAJOR STORM EVENTS, AND PROVIDE ADDITIONAL FUTURE
SHALL MONITOR EROSION THROUGHOUT THE PROJECT, ANNUALLY AND
DISCUSSIONS WITH TOWN STAFF. AFTER THE CONSTRUCTION, THE TOWN
EROSION CONTROL IS PROPOSED THROUGHOUT THE PROJECT BASED ON
REDESIGNS ARE NECESSARY.
WITH ADA GRADES AND SLOPES. COORDINATE WITH THE ENGINEER IF SLOPE
THE INTENT OF THE SIDEWALK AND RAMPS DESIGNS IS TO BE FULLY COMPLIANT
BY ENGINEERING & TESTING CONSULTANTS INC. AND IS DATED 2/20/2025.
THE GEOTECHNICAL REPORT FOR THIS PROJECT HAS BEEN COMPLETED
ENGINEER NOTES:
E
L
EST. 1995
.C
NI
G N I
Y E
V R
U S
& GNI
R
E
E N I
G N
E N
O
YL
DRAWING NUMBER
SHEET
LYON PROJECT #
W
S
E
G
T
OHE
CTV
FOT
A
B
C
D
1 2 3 4 5
FILENAME:G:\PROJECTS\523_TOWN_OF_PRESCOTT_VALLEY\523-33 Cattletrack Roadway and Pedestrian\CADD\DGN\PLANSET\Cattletrack-Roundup Sheets.dgn
REUSE OF DOCUMENTS:
SURVEYING, INC. AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF LYON ENGINEERING & SURVEYING, INC.
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF LYON ENGINEERING &
D E
S
IG
N
D R
A W
N
C H
E C
K E
D
A P
P R
O V
E D
VERIFY SCALE
SCALES ACCORDINGLY
THIS SHEET, ADJUST
IF NOT ONE INCH ON
0 20
B A
B
A P
V D
B Y
N O
D A
T E
R E
V
IS
IO
N S
D E
S C
R
IP
T
IO
N
ORIGINAL DRAWING.
BAR IS ONE INCH ON
1"0
B A
B
B A
B
S A
L
G E
N E
R A
L
22"x34" sheets only)
(This scale is valid for
1" = 20 ft, Horizontal
DRAWING SCALE
523-33
R eg is te re d Pr ofe ssionalEngineer (C iv il)
AR
IZONA,U.S
.A
D a te
Signed
C
E R
TI
FICATE
N
O
47997
BRIAN A.
BUCHOLTZ
www.lyonengineering.com
(928) 776-1750
Prescott, AZ 86301
Building #2
2971 Willow Creek Road
C
IP
S
T
IM
P
R O
V E
M E
N T S P
R O J E
C T
P E
D E
S T
R
IA
N A
N D D
R A
IN
A G
E
C A
T T
L E
T R
A C
K R
O A
D
JANUARY 2026
G.03
P R
O J E
C T Q
U A
N T
IT
IE
S
S Y
M B
O L L
E G
E N
D
A B
B R
E V
IA
T
IO
N A
N D
QUANTITIES PRIOR TO BIDDING.
FOR INDEPENDENTLY ESTIMATING WORK
NOT BE RELIEVED OF HIS RESPONSIBILITY
AND INSTALLED. THE CONTRACTOR SHALL
ITEMS FOR ACTUAL QUANTITIES PROVIDED
PAYMENT SHALL BE BASED ON BID SCHEDULE
CORRESPOND TO ALL BID SCHEDULE ITEMS.
CONVENIENCE. THEY DO NOT NECESSARILY
FURNISHED SOLELY FOR THE CONTRACTOR'S
PUBLIC WORKS DIRECTOR, AND ARE
APPROXIMATE, ARE NOT VERIFIED BY THE
ALL QUANTITIES SHOWN ON THE PLANS ARE
NOTE:
ROAD, DRAINAGE, WATER, & SEWER
BARBED WIRE FENCE
EROSION MATTRESS
GROUTED RIPRAP
RIPRAP
HYDROSEED
HEADWALL
DRAINAGE CULVERT
UTILITIES
STRIPING
BRIAN A. BUCHOLTZ, P.E.
EXISTING FIBER OPTIC
EXISTING CABLE
EXISTING TELEPHONE
EXISTING GAS
EXISTING UNDERGROUND POWER
EXISTING OVERHEAD POWER
EXISTING SEWER
EXISTING WATER
WITHW/
POTABLE WATERW
VALLEY GUTTERVG
TYPICALTYP
TOP OF CURBTC
SQUARE YARDSSY
SIDEWALKSW
STANDARDSTD
SEWER SERVICESS
SPECIFICATIONSSPEC
SQUARE FOOTSF
STORM DRAINSD
SEWERS
RIGHTRT
RIGHT-OF-WAYROW
RIM GRADERIM
RIGHT-OF-WAYROW
PROPERTY LINEPL
POTHOLE LOCATIONPH
PAGEPG.
PAVEMENT GRADEP
MINIMUMMIN.
MANHOLEMH
MATCH EXISTINGME
MAXIMUMMAX.
MARICOPA ASSOCIATION OF GOVERNMENTSMAG
LEFTLT
LUMP SUMLS
LINEAR FEETLF
LENGTHL
INVERT ELEVATIONIE
HEADWALLHW
GATE VALVE BOX & COVERG.V.B.&C.
FLOW LINE ELEVATIONFL
FIRE HYDRANTFH
FINISH GRADE ELEVATIONFG
EXISTINGEX.
EASEMENTESMT
EDGE OF PAVEMENTEOP
ELEVATIONEL
DRAWINGDWG
DRIVEWAYDVWY
DRAINAGE SLOPEDS
DUCTILE IRON PIPEDIP
DETAILDET.
CUBIC YARDSCY
CONCRETECONC.
CLEAN OUTCO
CORRUGATED METAL PIPECMP
CENTERLINECL
CONCRETE ELEVATIONC
BACK OF CURBBOC
BLOW OFFBO
BOOKBK.
BACK OF CURBBC
AIR RELEASE VALVE ASSEMBLYARV
ARIZONA PUBLIC SERVICEAPS
APPROXIMATELYAPPROX.
ARIZONA DEPARTMENT OF TRANSPORTATIONADOT
ACREAC
AGGREGATE BASE COURSEA.B.C.
LONG LINE PAVEMENT MARKINGS
SHORT LINE PAVEMENT MARKINGS
MAG 106
MAG 401
ADOT 810
SW 904
SW 903
MAG 520
SW 902
ADOT 704
ADOT 704
ADOT 704
ADOT 704
ADOT 704
ADOT 708
ADOT 708
ADOT 708
ADOT 708
ADOT 708
ADOT 608
ADOT 607
MAG 610
MAG 630
MAG 610
MAG 610
MAG 430
MAG 220
MAG 220
MAG 505
MAG 505
MAG 618
MAG 505
MAG 505
MAG 505
MAG 618
MAG 618
MAG 618
MAG 340
MAG 340
MAG 340
MAG 340
MAG 340
MAG 340
MAG 340
MAG 340
MAG 333
MAG 310
MAG 310
MAG 310
MAG 310
SW 901
SW 901
MAG 321
MAG 321
MAG 321
MAG 350
MAG 350
MAG 350
MAG 350
MAG 350
MAG 350
MAG 350
MAG 350
MAG 350
MAG 336
MAG 215
Dry Utility Relocations
Quality Control
Traffic Control
SWPPP & Erosion Control
Pothole
Driveway Fence and Gates Replacement
Safety Rail
Mailbox
Thermoplastic Single White Stop Bar, 4" Equiv. (Final Application)
Thermoplastic Single White Stripe, 4" Equiv. (Final Application)
Thermoplastic Single Yellow Stripe, 4" Equiv. (Final Application)
Thermoplastic Double Yellow Stripe, 4" Equiv. (Final Application)
Thermoplastic White High Visibility Crosswalk Marking, 4" Equiv. (Final Application)
Painted Single White Stop Bar, 4" Equiv. (Initial Application)
Painted Single White Stripe, 4" Equiv. (Initial Application)
Painted Single Yellow Stripe, 4" Equiv. (Initial Application)
Painted Double Yellow Stripe, 4" Equiv. (Initial Application)
Painted White High Visibility Crosswalk Marking, 4" Equiv. (Initial Application)
Sign
Sign Post
Water Meter Box Adjustment
Water Valve Adjustment
Fire Hydrant Assembly
8" x 6" Tee
Hydroseed
Hand-Placed Riprap (D50=4", 8" Depth)
Hand-Placed Riprap (D50=9", 18" Depth)
Headwall Extension
Headwall
Nyloplast 18" Inline Drain with 18" Dome Grate
Catch Basin, Type 'D'
Storm Drain Manhole
Concrete Pipe Collar
24" RGRCP Culvert
18" RGRCP Culvert
18" HDPE Culvert
Stand-Alone Detectable Warning Panels
Parallel Curb Sidewalk Ramp
Local Street Sidewalk Ramp
Concrete Sidewalk
Curb Termination
Curb Transition
Vertical Curb & Gutter
Roll Curb & Gutter
Fog Seal
4" AB (Under Gravel Driveways)
6" AB (Under PCC Driveways)
4" AB (Path Adjacent to Roundup Drive)
9" AB (Roundup Drive and Cattletrack Road)
2" Gravel (Driveways)
6" PCC (Driveways)
2" AC, Type C 3/4" (Path Adjacent to Roundup Drive)
4" AC, Type C 3/4" (Cattletrack Road)
6" AC, Type C 3/4" (Roundup Drive)
Remove Existing Wooden Bridge Structure
Remove Existing Driveway Fence and Gates
Remove Existing Curb and Sidewalk
Remove Existing Mailbox
Remove Existing Culvert
Cut Existing Culvert
Cut and Remove Existing Tree
Remove Existing Sign
Remove Pavement
Sawcut Existing Pavement
Balance
Fill (To Finished Grade)
8" Overexcavation for 4" Riprap
18" Overexcavation for 9" Riprap
6" Overexcavation for Gravel Driveways
12" Overexcavation for PCC Driveways
12" Overexcavation for Sidewalk/Ramps
10" Overexcavation for Curb
13" Overexcavation for Roadway Pavement
6" Overexcavation for Path
Cut (To Finished Grade)
2,734
2,734
7,390
1,245
5,257
2,636
1,102
2,565
2,774
1,742
1,264
LS
LS
LS
LS
EA
EA
LF
EA
LF
LF
LF
LF
LF
LF
LF
LF
LF
LF
EA
EA
EA
EA
EA
EA
SY
SY
SY
EA
EA
EA
EA
EA
EA
LF
LF
LF
SF
EA
EA
SF
EA
EA
LF
LF
SY
SY
SY
SY
SY
SY
SF
SY
SY
SY
EA
EA
SF
EA
LF
EA
EA
EA
SY
LF
CY
CY
CY
CY
CY
CY
CY
CY
CY
CY
CY
PLANS SYMBOL LEGEND
UNITSDESCRIPTION OF ITEM
PROJECT QUANTITIES
QUANTITY
TOTAL
ABBREVIATION LEGEND
MISCELLANEOUS
SPEC. NO.
PAYITEM
ITEM NO.
BID
EARTHWORK (TOTAL)
SIGNAGE & PAVEMENT MARKINGS
PRIOR TO CIVIL CONSTRUCTION
REMOVALS
FOR SLOPE ANGLES.
VIEW AND DO NOT ACCOUNT
ARE MEASURED FROM PLAN
(RIPRAP AND GROUTED RIPRAP)
-SURFACE TREATMENT QUANTITIES
OR SPOILS.
NOT INCLUDE SHRINK OR SWELL
APPROXIMATE, RAW, AND DO
-GRADING QUANTITIES ARE
NOTES:
ROADWAY
WATER
DRAINAGE E
L
EST. 1995
.C
NI
G N I
Y E
V R
U S
& GNI
R
E
E N I
G N
E N
DRAWING NUMBER
SHEET
LYON PROJECT #
A
B
C
D
1 2 3 4 5
FILENAME:G:\PROJECTS\523_TOWN_OF_PRESCOTT_VALLEY\523-33 Cattletrack Roadway and Pedestrian\CADD\DGN\PLANSET\Cattletrack-Roundup Sheets.dgn
REUSE OF DOCUMENTS:
SURVEYING, INC. AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF LYON ENGINEERING & SURVEYING, INC.
THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF LYON ENGINEERING &
D E
S
IG
N
D R
A W
N
C H
E C
K E
D
A P
P R
O V
E D
VERIFY SCALE
SCALES ACCORDINGLY
THIS SHEET, ADJUST
IF NOT ONE INCH ON
A P
V D
B Y
N O
D A
T E
R E
V
IS
IO
N S
D E
S C
R
IP
T
IO
N
ORIGINAL DRAWING.
BAR IS ONE INCH ON
1"0
R eg is te re d Pr ofe ssionalEngineer (C iv il)
AR
IZONA,U.S
.A
D a te
Signed
C
E R
TI
FICATE
N
O
47997
BRIAN A.
BUCHOLTZ
G E
N E
R A
L
B A
B
B A
B
B A
B
S A
L www.lyonengineering.com
(928) 776-1750
Prescott, AZ 86301
Building #2
2971 Willow Creek Road
C
IP
S
T
IM
P
R O
V E
M E
N T S P
R O J E
C T
P E
D E
S T
R
IA
N A
N D D
R A
IN
A G
E
C A
T T
L E
T R
A C
K R
O A
D
523-33
22"x34" sheets only)
(This scale is valid for
1" = 80 ft, Horizontal
DRAWING SCALE
NOT A PART OF THIS PHASE
FOUND MONUMENT
FOR SURVEY INFORMATION ONLY
SURVEY MARKER TYPE "B", QCSD 120Q
SURVEY MARKER TYPE "A", QCSD 120Q
N 1,322,415.3602 E 577,226.8789 Sta 29+50.00
N 0°12'14.03" E Dist 1,950.00
N 1,320,465.3726 E 577,219.9395 Sta 10+00.00
N 1,320,510.5539 E 577,277.7724 Sta 13+50.00
N 89°56'48.41" E Dist 350.00
N 1,320,510.2288 E 576,927.7726 Sta 10+00.00
EL=4,921.770
E:577,190.9389
N:1,320,548.9905
2020 TPV RP_04
EL=4,944.728
E:577,213.682141 N:1,322,378.4560
SITE TBM
PROJECT
JANUARY 2026
BRIAN A. BUCHOLTZ, P.E.
G.04
S U
R V
E Y C
O N
T R
O L M
A P
N00º42'44"E S19
º07 '40
"E
1,829.61FT
E=577226.88 N=1322415.36
POT=29+50.00
E=576927.77 N=1320510.23
POB=10+00.00
E=577277.77 N=1320510.55
POT=13+50.00
E=577219.94 N=1320465.37
POB=10+00.00
E=577220.10 N=1320510.50
SI=12+92.33 (ROUNDUP)
SI=10+45.13 (CATTLETRACK)
88.
50F
T N11º10'46"E
39.19FT
MCKINNEY
103-35-753
HERNANDEZ
103-35-752
ARMSTRONG
103-35-751
KERMA
103-35-750
THOMPSON
103-35-749
RISO
103-35-748
CARTER
103-35-746A
ERB
103-35-745
GUNN
103-35-744
FORDSMAND
103-35-743
MIKE
103-35-742
PAULSEN
103-35-741
DECARO
103-35-740
GUNVALSON
103-35-739
CRAWFORD
103-35-738
CRAIGHEAD
103-35-737
O'BRIEN
103-35-736
AYALA
103-35-735
KILGORE
103-35-734
DEVILLE
103-35-733
COLLINS
103-35-732
HARRIS
103-35-731
MUNOZ
103-35-730
WILSON
103-35-729
MACIAS
103-35-483
JAECKEL
103-35-540
GRIFFIN
103-35-541
BIGELOW
103-35-568
RCJ TRUST
103-35-569
CALLAGHAN
103-35-564
ORTEGA
103-35-563
POSTON
103-35-561A
SCHUBERT
103-35-515
LAVINE
103-35-514
LEE
103-35-436A
CASTLE
103-35-435
ZEPEDA
103-35-377BECERRA
103-35-376
BURROWS
103-35-310
LEFEVRE
103-35-309
CATTLETRACK ROAD
R O
U N
D U P D
R
IV
E
M O
O N L
IG
H T W
A Y
W
IL
D H
O R S E D
R
IV
E
U N
IO
N D
R
IV
E
W A L N
U T W
A Y
C
IR
C L E
F A
W N
Y U
C C
A D
R
IV
E
PROJECT CENTERLINE GEOMETRICS
LEGEND
CATTLETRACK ROAD
ROUNDUP DRIVE
ARIZONA
STATE OF
800-20-034C
T O
W N O
F P
V -0
-6
T O
W N O
F P
V -0
-0
PRESCOTT VALLEY
TOWN OF
800-12-019N
PRESCOTT VALLEY
TOWN OF
800-12-006Q
GALLAGHER
103-35-308
ORTHOMETRIC ELEVATION: 4944.727939 (NAVD88)
E: 577213.682141 (AT GROUND)
N: 1322378.455989 (AT GROUND)
USED FOR DRONE (UAS) GROUND CONTROL POINT (GCP)
PAINTED WHITE CROSS
SET CONCRETE NAIL FLUSH WITH THE PAVEMENT IN THE CENTER OF A
LYON ENG POINT: 3008
PROJECT SITE TEMPORARY BENCHMARK (TBM)
HELD AT TOWN OF PRESCOTT VALLEY BENCHMARK REFERENCE POINT 21
COMBINED GRID TO GROUND SCALE FACTOR: 1.000323377422
MODIFIED TO GROUND COORDINATES
VERTI…
This is the start of the file's text. The full file is on GovTribe.