1.01d TSV-3 HUNTER GAGE LIST.xlsx
XLSX spreadsheet 20 KB Posted
- Attached to
- Calibration Services
- Solicitation number
- N0018926QL018
About this file
This is a gage calibration requirements list for the TSV-3 Hunter vessel, specifying instrumentation across multiple ship systems requiring calibration services. The document lists approximately 85 distinct gages and measuring instruments organized by system category, including main engines (starboard and port), auxiliary systems, electrical systems, hydraulic systems, and specialized equipment. Each gage entry identifies the nomenclature, measurement range, units, and calibration due date.
Critical calibration deadlines range from May 21, 2024 through April 21, 2025, with several items already past due as of September 2024. Primary instrumentation categories include engine performance monitoring (cylinder exhaust temperature, tachometers, manifold air temperature, oil and fuel pressure), hydraulic systems (brake and steering gear pressures up to 30,000 PSIG), electrical monitoring (voltage and amperage), and specialized systems such as the reverse osmosis unit, fire pump, bow thruster engine, and air compressors. Temperature measurement ranges span 0-1,300 degrees Fahrenheit for exhaust monitoring and 0-250 degrees Fahrenheit for fluid temperatures, while pressure measurements range from 0-30 PSIG for compressor lubrication oil to 0-30,000 PSIG for steering gear hydraulics. This requirements list directly supports the Navy's Calibration Services solicitation (N0018926QL018) issued by NAVSUP Fleet Logistics Center Norfolk, a small business set-aside acquisition using NAICS code 811310 for machinery repair and maintenance services.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation - N0018926QL018.pdf | ||
| 1.01f TSV-3 HUNTER Gauge List 16OCT25 exp MAY27.xlsx | XLSX spreadsheet | |
| 4.02 Solicitation - N0018926RL002.pdf | ||
| 1.01l Additional Info.pdf | ||
| 1.01h TSV4 Narragansett Gauge List Exp JAN26.xls | XLS spreadsheet | |
| 1.0h TSV5 VINDICATOR GAGE CAL LOG.xlsx | XLSX spreadsheet | |
| 1.01g TSV4 Narragansett Gauge List Exp AUG25.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| TSV-3 HUNTER GAGE LIST | |||||
| GAGE NOMENCLATURE | RANGE | UNITS | DUE DATE | COUNTER | |
| STBD MAIN ENGINE | |||||
| CYLINDER EXHAUST TEMP | 0-1300 | DEG F | 5/21/24 | 1 | |
| TACHOMETER | DIGITAL | RPM | 5/21/24 | 1 | |
| LEFT MANIFOLD AIR TEMP | 0-160 | DEG F | 5/21/24 | 1 | |
| RIGHT MANIFOLD AIR TEMP | 0-160 | DEG F | 5/21/24 | 1 | |
| L/R COMBINED EXHAUST TEMP | 0-1200 | DEG F | 5/21/24 | 1 | |
| L.O. TEMPERATURE | 130-250 | DEG F | 4/21/25 | 1 | |
| J.W. TEMPERATURE | 0-250 | DEG F | 4/21/25 | 1 | |
| L.O. PRESSURE | 0-100 | PSIG | 5/21/24 | 1 | |
| F.O. PRESSURE | 0-50 | PSIG | 5/21/24 | 1 | |
| GEAR OIL TEMPERATURE | 100-250 | DEG F | 5/21/24 | 1 | |
| GEAR OIL PRESSURE | 0-400 | PSIG | 5/21/24 | 1 | |
| RACOR F.O. FILTER DIFFERENTIAL PRESSURE | 0-30 | "Hg | - | 1 | |
| L.O. PRESSURE LOCAL GAGE | 0-200 | PSIG | 4/21/25 | 1 | |
| L.O. FILTER PRESSURE INLET | 0-100 | PSIG | 9/30/24 | 1 | |
| L.O. FILTER PRESSURE INLET | 0-100 | PSIG | 9/30/24 | 1 |
| S.M.E. CLUTCH CTRL | |||||
| SPEED AIR SIGNAL | 0-100 | PSIG | 5/21/24 | 1 | |
| PRESS GAGE NO. 1 (TOP) | 0-200 | PSIG | 5/21/24 | 1 | |
| PRESS GAGE NO. 1 (MIDDLE) | 0-200 | PSIG | 5/21/24 | 1 | |
| PRESS GAGE NO. 1 (BOTTOM) | 0-200 | PSIG | 5/21/24 | 1 | |
| AIR PRESSURE REDUCING STATION 1 | 0-160 | PSIG | 9/16/20 | 1 | |
| AIR PRESSURE REDUCING STATION 2 | 0-200 | PSIG | 9/16/20 | 1 | |
| AIR PRESSURE REDUCING STATION 3 | 0-200 | PSIG | 9/16/20 | 1 |
| S.M.E HYDRAULIC BRAKE | |||||
| HYDRAULIC PRESSURE | 0-3000 | PSIG | 4/21/25 | 1 |
| PORT MAIN ENGINE | |||||
| CYLINDER EXHAUST TEMP | 0-1300 | DEG F | 5/21/24 | 1 | |
| TACHOMETER | DIGITAL | RPM | 5/21/24 | 1 | |
| LEFT MANIFOLD AIR TEMP | 0-160 | DEG F | 5/21/24 | 1 | |
| RIGHT MANIFOLD AIR TEMP | 0-160 | DEG F | 5/21/24 | 1 | |
| L/R COMBINED EXHAUST TEMP | 0-1200 | DEG F | 5/21/24 | 1 | |
| L.O. TEMPERATURE | 130-250 | DEG F | 5/21/24 | 1 | |
| J.W. TEMPERATURE | 0-250 | DEG F | 5/21/24 | 1 | |
| L.O. PRESSURE | 0-100 | PSIG | 5/21/24 | 1 | |
| F.O. PRESSURE | 0-50 | PSIG | 5/21/24 | 1 | |
| GEAR OIL TEMPERATURE | 100-250 | DEG F | 5/21/24 | 1 | |
| GEAR OIL PRESSURE | 0-400 | PSIG | 5/21/24 | 1 | |
| RACOR F.O. FILTER DIFFERENTIAL PRESSURE | 0-30 | "Hg | - | 1 | |
| L.O. PRESSURE LOCAL GAGE | 0-200 | PSIG | 4/21/25 | 1 | |
| L.O. FILTER PRESSURE INLET | 0-100 | PSIG | 9/30/24 | 1 | |
| L.O. FILTER PRESSURE INLET | 0-100 | PSIG | 9/30/24 | 1 |
| P.M.E. CLUTCH CTRL | |||||
| SPEED AIR SIGNAL | 0-100 | PSIG | 5/21/24 | 1 | |
| PRESS GAGE NO. 1 (TOP) | 0-200 | PSIG | 5/21/24 | 1 | |
| PRESS GAGE NO. 1 (MIDDLE) | 0-200 | PSIG | 5/21/24 | 1 | |
| PRESS GAGE NO. 1 (BOTTOM) | 0-200 | PSIG | 5/21/24 | 1 | |
| AIR PRESSURE REDUCING STATION 1 | 0-160 | PSIG | 9/16/20 | 1 | |
| AIR PRESSURE REDUCING STATION 2 | 0-160 | PSIG | 9/16/20 | 1 | |
| AIR PRESSURE REDUCING STATION 3 | 0-300 | PSIG | 9/16/20 | 1 |
| P.M.E HYDRAULIC BRAKE | |||||
| HYDRAULIC PRESSURE | 0-3000 | PSIG | 5/21/24 | 1 |
| THROTTLES (LOCAL CTRL) | |||||
| PORT THROTTLE AIR PRESSURE | 0-200 | PSIG | 4/21/25 | 1 | |
| STBD THROTTLE AIR PRESSURE | 0-200 | PSIG | 4/21/25 | 1 |
| BOW THRUSTER ENGINE | |||||
| AIR REDUCING STATION | 0-300 | PSIG | 5/21/23 | 1 | |
| TACHOMETER | 0-2500 | RPM | 5/21/24 | 1 | |
| F.O. PRESSURE | 0-50 | PSIG | 5/21/24 | 1 | |
| J.W. TEMPERATURE | NO SCALE | - | - | 1 | |
| L.O. PRESSURE | 0-80 | PSIG | 5/21/24 | 1 | |
| RACOR F.O. DIFFERENTIAL PRESSURE | 0-30 | "Hg | 5/21/24 | 1 |
| NO. 1 SSDG | |||||
| TACHOMETER | DIGITAL | DIGITAL | 5/21/24 | 1 | |
| F.O. PRESSURE | 0-100 | PSIG | 5/21/24 | 1 | |
| L.O. PRESSURE | 0-70 | PSIG | 5/21/24 | 1 | |
| J.W. TEMPERATURE | NO SCALE | NO SCALE | 4/21/25 | 1 | |
| RACOR F.O. DIFFERENTIAL PRESSURE | 0-30 | "Hg | 5/21/24 | 1 |
| NO. 2 SSDG | |||||
| TACHOMETER | DIGITAL | DIGITAL | 5/21/24 | 1 | |
| F.O. PRESSURE | 0-100 | PSIG | 5/21/24 | 1 | |
| L.O. PRESSURE | 0-70 | PSIG | 4/21/25 | 1 | |
| J.W. TEMPERATURE | NO SCALE | NO SCALE | 4/21/25 | 1 | |
| RACOR F.O. DIFFERENTIAL PRESSURE | 0-30 | "Hg | 5/21/24 | 1 |
| MAIN SWITCHBOARD | |||||
| STBD SHORE POWER VOLTAGE | 0-600 | VOLTS | 5/21/24 | 1 | |
| STBD AMMETER | 0-300 | AMPS | 5/21/24 | 1 | |
| STBD FREQUENCY | 55-65 | HZ | 5/21/24 | 1 | |
| PORT FREQUENCY | 55-65 | HZ | 5/21/24 | 1 | |
| PORT AMMETER | 0-300 | AMPS | 5/25/23 | 1 | |
| PORT VOLTAGE | 0-600 | VOLTS | 5/21/24 | 1 | |
| GROUND AMP METER | UNK | DC AMPS | 5/21/24 | 1 |
| R.O. UNIT | |||||
| P1-1004 HP PUMP INLET PRESSURE | 0-160 | PSIG | - | 1 | |
| P1-1002 PREFILTER INLET PRESSURE | 0-160 | PSIG | - | 1 | |
| P1-1005 MEMBRANE INLET PRESSURE | 0-1500 | PSIG | - | 1 | |
| F1-1002 PRODUCT FLOWMETER | 0-10 | GPM | - | 1 |
| FIREPUMP | |||||
| FIREPUMP DISCHARGE PRESSURE | 0-200 | PSIG | 5/21/24 | 1 |
| STERN RAMP HYDRAULICS | |||||
| NO. 1 PUMP DISCHARE PRESSURE | 0-5000 | PSIG | 5/21/24 | 1 | |
| NO. 2 PUMP DISCHARE PRESSURE | 0-5000 | PSIG | 5/21/24 | 1 |
| NO. 1 AIR COMPRESSOR | |||||
| OUTLET AIR PRESSURE | 0-200 | PSIG | 4/21/25 | 1 | |
| COMPRESSOR L.O. PRESSURE | 0-30 | PSIG | - | 1 |
| NO. 2 AIR COMPRESSOR | |||||
| OUTLET AIR PRESSURE | 0-200 | PSIG | 5/21/24 | 1 | |
| COMPRESSOR L.O. PRESSURE | 0-30 | PSIG | - | 1 |
| STEERING GEAR HYD PUMPS | |||||
| NO. 1 PUMP DISCHARGE PRESSURE | 0-30000 | PSIG | 5/21/24 | 1 | |
| NO. 2 PUMP DISCHARGE PRESSURE | 0-30000 | PSIG | 5/21/24 | 1 |
| POTABLE WATER SYSTEM | |||||
| PPOTABLE WATER SYSTEM PRESSURE | 0-200 | PSIG | 5/21/24 | 1 |
File details come from the government source that posted it. Updated .