1-900 W. Overflow Lot Invitation to Bid.pdf
PDF 2 MB Posted
- Solicitation number
- PN 2025-23
- Issued by
- Salt Lake County, Utah
About this file
The document is a Public Notice Invitation to Bid issued by the City of South Salt Lake for a parking lot fence construction project located at 3291 S 900 West. The project involves materials, supplies, and installation of 8-foot-tall fencing, including mini chain link fencing along the East and South property sides and solid Trex Seclusions fencing along the West side and Southwest corner. A site visit is scheduled for November 5th at 10:00 AM, with additional site visit coordination available through Brent Dyer. Proposals will be accepted until November 13, 2025, at 3:00 PM MST, with submission options including in-person delivery, email, or direct submission to the Utah Public Procurement Portal.
The fencing specifications require a 1-inch diamond 11-gauge galvanized steel wire chain link fence with specific post and rail dimensions, and a solid Trex Seclusions fence in Woodland Brown color. The contractor will also be responsible for installing an owner-provided mechanical gate. The project includes additional site work such as installing a new 25-foot light pole, security camera conduit, coconut fiber blanket installation, and reseeding a retention basin. Contractors must meet all contracting and insurance requirements outlined in the Sample Agreement provided in the Project Manual.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2-900 W. Overflow Lot Project Manual.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PUBLIC NOTICE
Invitation to Bid
City of South Salt Lake: 900 West Parking Lot Fence Construction
The City of South Salt Lake will accept bids from qualified contractors to construct a city facility at 3291 S 900 West. The scope of work includes materials, supplies and installation of solid fencing and chain link fencing as shown on attached plan and per spec sheet. Install owner provided mechanical gate. No pre-bid conference will be held. A site visit will be held on Wednesday, November 5th at 10:00 AM. Additionally, a site visit can be coordinated with Brent Dyer
385.358.3698. Selected contractor will be required to meet all contracting and insurance requirements in the Sample Agreement provided in the Project Manual.
Proposals will be accepted until November 13, 2025 at 3:00pm MST. Bids may be submitted in person to the City Recorders office at South Salt Lake City Hall (220 E Morris Ave.), or by email at aandrus@sslc.gov, or accepted via direct submission to the Utah Public Procurement Portal (UP3). No late proposals will be accepted, and proposers are responsible for verifying timely receipt of their submission.
mailto:aandrus@sslc.gov
3291 S 900 W
Fencing Specification
Note: All fencing must be 8 feet tall per City Municipal requirements.
Mini Chain Link Fence : Planned for the along the East and South side of the Property per attached drawing in Blue.
o One (1) inch Diamond 11 gauge galvanized steel wire.
o 2 3/8” 40 weight Posts.
o 1/5/8” Top Rail.
o 7 gauge bottom wire.
o Post holes and concrete for common posts required to be
8” diameter. Corner posts and End post required to be 10” diameter. All post holes at least 30” depth.
Solid Fence – Planned for along the West side of the Property, and SW corner per attached drawing in Red.
o Basis of Desing: Trex Seclusions, 8 foot wide vertical panels, Woodlan Brown, see attached manufacturer’s specifications.
o Substitutions will be considered that meet the same general requirements of the Trex fencing.
Solid barrier No hollow fencing allowed
Gate – Owner provided mechanical gate o To be installed by contractor
M S
S
E P
P
PROJECT #
25-091
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R D
A T
E
C H
E C
K E
D B
Y
B F
C
D R
A W
N B
Y
M D
F
D E
S
IG
N E
D B
Y
M D
F
E S
I E
N G
IN
E
E R
IN
G
A N
D L
A N
D S
U R
V E
Y O
R S
C O
N S
U L
T
IN
G E
N G
IN
E
E R
S
D A
T E
-1
-2
-2
-1
F
A X
-2
-1
W E
S T
V A
L L
E Y
C
IT
Y
U T
W
E S
T
S
O U
T H
S U
IT
E
W
E S
T P
A R
K
IN
G L
O T
S O
U T
H S
A L
T L
A K
E
No. 343584
CAMPBELL
BRIAN F.
Brian F. Campbell
8/12/25
D
E R
G E
SI
R
E T
AT
TAT UOE F
A
H S
RP
FO N
SES OI
G R
I E
E N
E N
L
S
W
N
Ex. Parking Lot
South Salt Lake
3265 S 900 W
C-101
PLAN
SITE
OVERALL
MSS EX. SEWER MH
EX. WATER VALVE
EX.WATER METER BOX
EX. HYDRAULIC STRUCTURE
EX. LIGHT POLE
EX. IRRIGATION BOX
EX. ELECTRICAL BOX
SCALE 1:30
PRINT 11" X 17"
15 30 605
LEGEND
162'
SOUTH 900 WEST
UNTREATED BASE COURSE (8" REQ'D)
HMA (3" REQ'D)
ASPHALT PAVEMENT AREA
18'
AS REQUIRED TO REACH FINAL GRADE
FURNISH & INSTALL UNTREATED BASE COURSE
PAINT STRIPING
4" YELLOW
PAINT STRIPING
4" YELLOW
THROUGH INTERIOR OF LIGHT POLE.
OTHERS. CAMERA CONDUIT TO ROUTE
SECURITY CAMERA TO BE INSTALLED BY
NEW 25-FOOT LIGHT POLE PER DETAIL.
INSTALL CONCRETE POLE BASE &
LOCATION OF CONDUIT WITH CITY.
CONTRACTOR TO COORDINATE
1 x 2" CONDUIT W/ 1 CAT6 CAMERA WIRE
& 1#10 THW GND WIRE
1 x 2" CONDUIT W/ 2#8 THW POWER WIRE
CONSTRUCTION NOTES
EX. POWER
CONNECT TO
INSTALL COCONUT FIBER BLANKET (2750 S.F.)
RESEED RETENTION BASIN WITH CITY APPROVED SEED MIX
4" MIN SCREENED TOPSOIL.
BLANKET OVER SEEDED AREAS
INSTALL COCONUT FIBER
P A
R K
IN
G
L O
T D
IM
E
N S
IO
N
S
D R
IV
E
W A
Y -2
-2
Owner Provided Mechanical Gate
8' Non-clumb Chainlink per spec
8' Trex fence per spec steven_niederhauser Line steven_niederhauser Line steven_niederhauser Line steven_niederhauser Line steven_niederhauser Line steven_niederhauser Line steven_niederhauser Line steven_niederhauser Line steven_niederhauser Line steven_niederhauser Line steven_niederhauser Line steven_niederhauser Line steven_niederhauser Line steven_niederhauser Line steven_niederhauser Line
| Invitation-900 W Parking Lot Construction |
| 3291 S 900 W Fencing Spec's |
| 900 W Parking Lot Fence Bid Plan |
| Untitled |
File details come from the government source that posted it. Updated .