Grease Trap Cleaning Scope of Work.pdf
PDF 53 KB Posted
- Solicitation number
- 09242026
About this file
This is a Compliance and Performance Framework document for a federal contract to provide complex-wide quarterly grease trap maintenance and cleaning services at Federal Correctional Complex (FCC) Yazoo City in Mississippi for fiscal year 2027.
The contractor must service 11 grease trap units totaling 47,500 gallons capacity across four functional zones: Camp Zone (3 units, 9,000 gallons), Low Security I (3 units, 6,000 gallons), Low Security II (2 units, 10,000 gallons), and USP-Medium Facility (3 units, 22,500 gallons). Services must be performed exactly four times per year during specified quarters (October-December 2026, January-March 2027, April-June 2027, and July-September 2027), with scheduling determined by the Complex Food Service department rather than contractor discretion. The scope of work requires comprehensive tank assessment, total content evacuation via vacuum pumping, mechanical scraping of all internal walls and baffles to remove hardened grease and sediment, and hydro-flushing of internal surfaces and plumbing lines. Skimming and partial pumping are strictly prohibited. Payment is contingent upon submission of verifiable disposal manifests or official evidence of proper legal disposal.
Mandatory qualifications include an MSDH Certified Pumper License under Mississippi Code 15 Miss. Code R. 18-77-2.1.37, documentation of an approved MDEQ disposal site, equipment verification complying with Mississippi state standards, and general business liability insurance with minimum limits of $50,000 per occurrence and $100,000 aggregate. The contractor must maintain records for at least two years and comply with all institutional security requirements, including NCIC background clearances for all personnel and tool inventory logging at facility entry and exit.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Grease Trap Cleaning Scope of Work - Updated.pdf | ||
| Grease Trap Cleaning Scope of Work.pdf | ||
| Grease Trap Cleaning Scope of Work.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Compliance and Performance Framework: FCC Yazoo City Project Title: Complex-Wide Quarterly Grease Trap Maintenance and Cleaning Location: Federal Correctional Complex (FCC) Yazoo City, 2225 Haley Barbour Pkwy, Yazoo City, MS 39194 Fiscal Year: 2027
1. Mandatory State Licensing Requirements
The Prime Contractor and all subcontractors must hold active solid waste hauling permits and specific state credentials in accordance with Mississippi regulations:
• MSDH Certified Pumper License: Required under 15 Miss. Code. R. 18-77-2.1.37 to legally clean, pump, haul, and dispose of waste from grease traps, holding tanks, and septic systems.
• Disposal Site Approval: Applicants must provide documentation of an approved disposal site authorized by the Mississippi Department of Environmental Quality (MDEQ) Office of Pollution Control.
• Equipment Verification: All pumping and hauling equipment must satisfactorily comply with Mississippi state standards.
• Liability Insurance: Proof of a valid general business liability insurance policy with minimum limits of $50,000 per occurrence and $100,000 in total aggregate amount.
• Fees and Renewal: License fees must be maintained on a designated three-year renewal cycle.
• Manifests and Record Keeping: Pursuant to Mississippi Code § 41-67-39, a tracking manifest confirming the pumping, hauling, and ultimate legal disposal of waste must be maintained. Records of grease trap work must be kept on file for at least 2 years.
2. Government-Furnished Equipment Inventory
The contractor is responsible for servicing a total of 11 grease trap units across 4 functional zones, representing a total complex capacity of 47,500 gallons:
Functional Area Location Total Unit Assets Individual Tank Capacity Cumulative Area Volume
Camp Zone 3 3,000 Gallons 9,000 Gallons
Low Security I 3 2,000 Gallons 6,000 Gallons
Low Security II 2 5,000 Gallons 10,000 Gallons
USP-Medium Facility 3 7,500 Gallons 22,500 Gallons
Complex Aggregates 11 Units — 47,500 Total Gallons
3. Technical Performance Requirements (Scope of Work)
Skimming or partial pumping is strictly prohibited. The contractor must systematically execute the following technical requirements for all institutional grease traps:
• Comprehensive Assessment: Prior to pumping, visually inspect the structural integrity of each tank, including checking the configuration of baffles, lids, and seals. Instantly report defects, structural failures, or plumbing backlogs to the Food Service Administrator.
• Total Content Evacuation: Vacuum-pump the entire liquid and solid contents of each trap down to the bottom.
• Mechanical Wall & Baffle Scraping: Thoroughly remove all hardened, adhered grease scale, scum crusts, and accumulated sediment layers by manually or mechanically scraping all internal walls, partitions, and structural baffles.
• Hydro-Flushing & Detail Washdown: Detail wash or hydro-flush internal trap surfaces, components, and inlet/outlet plumbing lines to remove residual grease filming. Ensure lids are tightly resealed upon completion.
4. Schedule & Administrative Rules
• Performance Frequency: Executed strictly four (4) times per fiscal year: Quarter 1 (Oct–Dec 2026), Quarter 2 (Jan–Mar 2027), Quarter 3 (Apr–Jun 2027), and Quarter 4 (Jul–September 2027).
• Operational Scheduling: The contractor shall not self-schedule. Individual service execution dates are designated via official notice from the Complex Food Service department inside standard operating windows.
• Disposal Manifests & Payment: Verifiable manifests or official evidence of proper legal disposal must be provided to the Complex Food Service Administrator upon completion of each quarterly cycle. Payment processing is strictly contingent upon receipt of this verification data.
5. Institutional Security Regulations
• Background Clearances: All service personnel (including subcontractors) must clear an NCIC background check and secure approved institutional security clearances prior to entering the secure federal facility.
• Tool Control & On-Site Rules: All tools, vacuum lines, and equipment brought inside the secure perimeter must be inventoried and logged upon entry and exit. Personnel must strictly adhere to all institutional security policies dictated by the warden and correctional staff.