08DOA-S2982 NCAS RFP Projects.xlsx

XLSX spreadsheet 32 KB Posted

Attached to
Nevada Camera/Card Access Security Systems
Solicitation number
08DOA-S2982
Issued by
Lyon County, Nevada

About this file

This document is an Excel file that contains information related to three state and local contract opportunities for access control and video surveillance systems. The first opportunity, "Small Project", involves installing access control for 20 doors in a new state building, including readers, door contacts, request-to-exit devices, and electric strikes, as well as cameras, network video recorders, and cabling. The second opportunity, "Large Project", is for a larger project of 100 doors with similar requirements. The third opportunity, "Maintenance", is for replacing hardware and wiring for 2 doors at a state fiber hut building due to potential lightning damage.

The document provides part numbers, quantities, and pricing information for the required equipment and materials. The projects will be added to the state's existing enterprise access control and video surveillance system. The state is providing the licensing, application, and database server for the CCURE system. The projects have varying requirements in terms of the number of doors, reader types, and camera models. Bidders are required to fill out the highlighted fields in the spreadsheet to provide pricing and labor hour estimates.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Small Project State is providing licensing for CCURE along with the application and database server. This project will be an add on to the existing enterprise system.

In Place (not to be considered):

-Category cabling for the camera -Network hardware needed for a connection -Conduit -Door Handles -System Programming Scenario: New State building needs 20 doors to have access control installed and ready to be added their existing enterprise system. Each door must include 1 reader, 1 door contact, 1 REX, and 1 electric strike. One of the doors needs to have a SWH-TST-100 reader installed. The cameras, NVRs, and wiring have been preselected below as part of this project. There is one data room (Intermediate Distribution Frame (IDF)) in the building for the equipment. The ceiling throughout the building is drop ceiling tiles.

**HIGHLIGHTED FIELDS MUST BE FILLED OUT**
ManufacturerPart NumberDescriptionMaterial QuantityMaterial Total CostLabor Total CostTotal Row Cost
Software HouseGSTAR-GCMiSTAR Ultra G2 GCM Board$0.00$0.00$0.00
Software HouseGSTAR-ACMiSTAR Ultra G2 ACM Board$0.00$0.00$0.00
Software HousePSX-WPUM16E8SNPower Supply with Enclosure and Net Card$0.00$0.00$0.00
Software HouseSWH-TST-100Scramble Pad Reader$0.00$0.00$0.00
WavelynxWVL-ET20-7WSWavelynx Reader$0.00$0.00$0.00
BoshDS160REX Motion$0.00$0.00$0.00
BoshTP160REX Back Plate$0.00$0.00$0.00
GRI195-12-WRecessed Door Contact$0.00$0.00$0.00
HES8000C-630No Cut Electric Strke$0.00$0.00$0.00
American DynamicsIPS08-C10-OI04Illustra Pro Gen4 8MP Compact Dome10$0.00$0.00$0.00
American DynamicsIPS12-F27-OIA4Pro Gen4 12MP Fisheye1$0.00$0.00$0.00
American DynamicsIPS32-M13-OIA4Illustra Pro Gen4 32MP Multisensor4$0.00$0.00$0.00
American DynamicsIFS16-M10-OIA4Illustra Flex Gen4 16MP Dual Sensor1$0.00$0.00$0.00
American DynamicsIPS05-R10-OIA4Illustra Pro Gen4 5MP, Corner2$0.00$0.00$0.00
American DynamicsADVER120R5DJVideoEdge Rack Mount NVR, 120TB1$0.00$0.00$0.00
Windy City446100-OSDP-WCW500OSDP Composite Access Control Cable2000 feet$0.00$0.00$0.00

Grand Total $0.00

Total Labor Hours

Large Project State is providing licensing for CCURE along with the application and database server. This project will be an add on to the existing enterprise system.

In Place (not to be considered):

-Category cabling for the camera -Network hardware needed for a connection -Conduit -Door Handles

Scenario: New State building needs 100 doors to have access control installed and ready to be added their existing enterprise system. Each door must include 1 reader, 1 door contact, 1 REX, and 1 electric strike. Five of the doors needs to have a SWH-TST-100 reader installed. The cameras, NVRs, and wiring have been preselected below as part of this project. There are two data rooms (Intermediate Distribution Frame (IDF)) in the building for the equipment with 50 doors going to each. The ceiling throughout the building is drop ceiling tiles.

**HIGHLIGHTED FIELDS MUST BE FILLED OUT**
ManufacturerPart NumberDescriptionMaterial QuantityMaterial Total CostLabor Total CostTotal Row Cost
Software HouseGSTAR-GCMiSTAR Ultra G2 GCM Board$0.00$0.00$0.00
Software HouseGSTAR-ACMiSTAR Ultra G2 ACM Board$0.00$0.00$0.00
Software HousePSX-WPUM16E8SNPower Supply with Enclosure and Net Card$0.00$0.00$0.00
Software HouseSWH-TST-100Scramble Pad Reader$0.00$0.00$0.00
WavelynxWVL-ET20-7WSWavelynx Reader$0.00$0.00$0.00
BoshDS160REX Motion$0.00$0.00$0.00
BoshTP160REX Back Plate$0.00$0.00$0.00
GRI195-12-WRecessed Door Contact$0.00$0.00$0.00
HES8000C-630No Cut Electric Strke$0.00$0.00$0.00
American DynamicsIPS08-C10-OI04Illustra Pro Gen4 8MP Compact Dome30$0.00$0.00$0.00
American DynamicsIPS12-F27-OIA4Pro Gen4 12MP Fisheye4$0.00$0.00$0.00
American DynamicsIPS32-M13-OIA4Illustra Pro Gen4 32MP Multisensor10$0.00$0.00$0.00
American DynamicsIFS16-M10-OIA4Illustra Flex Gen4 16MP Dual Sensor6$0.00$0.00$0.00
American DynamicsIPS08-B13-OIA4Illustra Pro Gen4 8MP Std Bullet (LPR only)2$0.00$0.00$0.00
American DynamicsIPS05-R10-OIA4Illustra Pro Gen4 5MP, Corner8$0.00$0.00$0.00
American DynamicsADVER120R5DJVideoEdge Rack Mount NVR, 120TB2$0.00$0.00$0.00
Windy City446100-OSDP-WCW500OSDP Composite Access Control Cable6000 feet$0.00$0.00$0.00

Grand Total $0.00

Total Labor Hours

Maintenance State is providing licensing for CCURE along with the application and database server. This project will be an add on to the existing enterprise system.

In Place (not to be considered):

-Category cabling for the camera -Network hardware needed for a connection -Conduit -Door Handles

Scenario: A service call came in stating the 2 doors are not working on the State Fiber Hut building in Austin, Nevada due to a possible lightning strike. All hardware and wiring needs to be replaced. Each door must include 1 reader, 1 door contact, 1 REX, and 1 electric strike. The wiring has been preselected below as part of this project. This is a single room brick building with conduit piping to all wiring locations.

**HIGHLIGHTED FIELDS MUST BE FILLED OUT**
ManufacturerPart NumberDescriptionMaterial QuantityMaterial Total CostLabor Total CostTotal Row Cost
Software HouseGSTAR004iSTAR Edge G2 Panel with Enclosure$0.00$0.00$0.00
Software HousePSX-WPUM16E8SNPower Supply with Enclosure and Net Card$0.00$0.00$0.00
WavelynxWVL-ET10-7WSWavelynx Mullion Reader$0.00$0.00$0.00
BoshDS160REX Motion$0.00$0.00$0.00
BoshTP160REX Back Plate$0.00$0.00$0.00
GRI195-12-WRecessed Door Contact$0.00$0.00$0.00
HES8000C-630No Cut Electric Strke$0.00$0.00$0.00
Windy City446100-OSDP-WCW500OSDP Composite Access Control Cable100 feet$0.00$0.00$0.00

Grand Total $0.00

Total Labor Hours

File details come from the government source that posted it. Updated .