These documents contain a Trane Order Report and detailed specifications and technical documentation for a Trane Performance Climate Changer Air Handler Unit (AHU-2) for outdoor installation at a facility requiring AHU replacements.
The order (W2F721B) is configured as an outdoor unit with a 19,000 CFM supply fan and return/exhaust fan capacity, sized at 40 with slate gray paint finish and UL listing. The unit incorporates six modular sections: return fan section (Position 1), air mixing section (Position 2), controls/VFD section (Position 3), filter section (Position 4) with MERV 13 pleated media filters, cooling coil section (Position 5) with 8-row chilled water coil rated at 645.07 MBh total capacity, and supply fan section (Position 6). The unit features 2-inch foam-injected double-wall construction with R-13 insulation, galvanized steel interior panels, integral 6-inch base frame, and standing seam roof design for outdoor applications. Both fans are equipped with VFDs: the return fan operates at 20 HP/1,800 RPM producing 2.031 in H2O static pressure at 1,997 operating RPM, while the supply fan operates at 25 HP/1,800 RPM producing 3.900 in H2O static pressure at 2,139 operating RPM. The unit ships in three sections with maximum individual weight of 3,674 lbs and installed weight of 8,147 lbs. Water coil connections use 1/2-inch OD copper tubes with aluminum fins, 84 fins per foot, stainless steel casing, and connections extending beyond the unit casing for field piping. The specifications require compliance with ASHRAE 90.1 damper leakage standards, AHRI Standards 410 and 430 for coil and fan certification, NFPA 90A for casing construction, and seismic requirements per IBC standards for the isolation system.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TRANE ORDER REPORT
ORDER NAME
W2F721B
BL
A
REV
ORDER TYPE
SO
BUSINESS UNIT
LEXLEXLexington
S N
PCODE
VAL-DATE
09/19/2003 11:02:11
PIC-DATE
09/19/2003 11:02:36
FEED MFG-DATE
10/08/2003 09:53:43
BACKWARD DATE
01/01/0001 00:00:00
INCLUDED ECNS
***** PCB DETAILS *****
POS COIL SEQ PRODUCT GROUP QTY HEADER TYPE PROD CODE
AA 0 0 CC02 1 B 0151
TYPE RULE CATG CODE SPC DESCRIPTION
FCAT S MODU UTSC N UNIT OPTIONS-TSC
FCAT S SIZE 40 N SIZE 40
VCAT S UCFM 19000 N UNIT CFM - SUPPLY FAN
VCAT O ULEN 257.50 N UNIT LENGTH (INCHES)
FCAT S PANT FACT N FACTORY PAINT-EXECUTIVE BEIGE
FCAT O CRBT STD N STANDARD TYPE ROOF CURB
FCAT S MODL TSCA N T-SERIES CLIMATE CHANGER
FCAT S DSEQ C N NEW NAMEPLATE
FCAT O UL YES N UL LISTED UNIT
FCAT S SFDL L N SUPPLY FAN LEFT SIDE DRIVE
POS COIL SEQ PRODUCT GROUP QTY HEADER TYPE PROD CODE
01 0 0 FN02 1 M 0151
TYPE RULE CATG CODE SPC DESCRIPTION
FCAT S MODU FAN N T-SERIES FAN MODULE
FCAT O SPEC SPEC Y SPECIAL OPTION (SEE NOTES)
FCAT S SHIP EELD N AIR ENT-EOU / AIR LVG-STD
FCAT S INSL BS15 N INSULATION 2" DW SOLID
FCAT S ADOR L N DOOR LEFT HAND
FCAT O LGHT ML N MARINE LIGHT
FCAT S FSIZ SPEC Y SPECIAL
FCAT O WBAL SPEC Y SPECIAL
FCAT S ISOL SPEC Y SPECIAL
FCAT S RALO SPEC Y SPECIAL
FCAT S DCHG SPEC Y SPECIAL
FCAT S DRLO SPEC Y SPECIAL
FCAT S DSFT SPEC Y SPECIAL
FCAT S MSHP SPEC Y SPECIAL
FCAT S MCIS SPEC Y SPECIAL
FCAT S MVLT SPEC Y SPECIAL
FCAT S MFRM SPEC Y SPECIAL
FCAT S CYCL 60 N 60 CYCLE MOTOR
FCAT O NEMA VFDB N SQUARE D VAR FREQ DRIVE W/BP
FCAT S DSEQ E N LINE FEED STR PLT CHNG
VCAT S FCFM 00000 N FAN CFM
VCAT S RPMF 0000 N FAN RPM
VCAT S BHPF 00.000 N FAN MOTOR BHP
VCAT O TSP 0.0000 N FAN TSP
FCAT S EXGL SPEC Y SPECIAL
FCAT O HRN1 NONE N HR #1 not present FCAT O HRN2 NONE N HR #2 not present FCAT O HRN3 NONE N HR #3 not present
VCAT O LGTH 62.000 N MODULE LENGTH
VCAT O WGHT 3373.8 N MODULE WEIGHT
VCAT O WDTH 113.00 N MODULE WIDTH
VCAT O HGTH 68.000 N MODULE HEIGHT
VCAT S SHPG 1.0000 N SHIPPING GROUP
POS COIL SEQ PRODUCT GROUP QTY HEADER TYPE PROD CODE
02 0 0 EM02 1 M 0151
W2F721B
BL
A
REV
ORDER TYPE
SO
BUSINESS UNIT
LEXLEXLexington
S N
PCODE
VAL-DATE
09/19/2003 11:02:11
PIC-DATE
09/19/2003 11:02:36
FEED MFG-DATE
10/08/2003 09:53:43
BACKWARD DATE
01/01/0001 00:00:00
INCLUDED ECNS
TYPE RULE CATG CODE SPC DESCRIPTION
FCAT S MODU ECON N ECONOMIZER MODULE
FCAT S ETYP ECON N RETURN FAN ECONOMIZER
FCAT S SHIP EDLD N AIR ENT-STD / AIR LVG-STD
FCAT S INSL BS15 N 2" INSULATION DW SOLID
FCAT O ADOR R N DOOR RIGHT HAND
FCAT O LGHT ML N MARINE LIGHT
FCAT O LOCA L N OUTSIDE AIR-LEFT HAND SIDE
FCAT O ECON FULL N 0-100% OUTSIDE AIR
FCAT S DMP1 PARL N 1ST OUTSIDE AIR-PARALLEL BLADE
FCAT O TYP1 ELIM N 1ST OUTSIDE AIR HOOD W/ELIM
FCAT S DMP2 PARL N 2ND OUTSIDE AIR-PARALLEL BLADE
FCAT O TYP2 ELIM N 2ND OUTSIDE AIR HOOD W/ELIM
FCAT S DCNT PARL N RETURN AIR-PARALLEL BLADE
FCAT S EDMP PARL N EXHAUST AIR-PARALLEL BLADE
FCAT O EXHD HOOD N EXHAUST HOOD
FCAT S DSEQ C N NEW ATS or LL IF REQUIRED FCAT O HRN1 NONE N HR #1 not present FCAT O HRN2 NONE N HR #2 not present FCAT O HRN3 NONE N HR #3 not present
VCAT O LGTH 84.000 N MODULE LENGTH
VCAT O WGHT 1889.0 N MODULE WEIGHT
VCAT O WDTH 113.00 N MODULE WIDTH
VCAT O HGTH 68.000 N MODULE HEIGHT
VCAT S SHPG 1.0000 N SHIPPING GROUP
POS COIL SEQ PRODUCT GROUP QTY HEADER TYPE PROD CODE
03 0 0 FA02 1 M 0151
TYPE RULE CATG CODE SPC DESCRIPTION
FCAT S MODU FILA N FILTER MODULE FLAT/ANGLED
FCAT S FTYP F N FLAT FILTER MODULE
FCAT S SHIP EDLD N AIR ENT-STD / AIR LVG-STD
FCAT S INSL BS15 N INSULATION 2" DW SOLID
FCAT S ADOR R N RIGHT HAND DOOR
FCAT S FFRM 2 N 2" FILTER FRAME
FCAT O F1FT PM N PLEATED MEDIA UNIT FILTERS
FCAT S DSEQ A N FIRST SHIP
FCAT O HRN1 NONE N HR #1 not present FCAT O HRN2 NONE N HR #2 not present FCAT O HRN3 NONE N HR #3 not present
VCAT O LGTH 11.500 N MODULE LENGTH
VCAT O WGHT 252.00 N MODULE WEIGHT
VCAT O WDTH 113.00 N MODULE WIDTH
VCAT O HGTH 68.000 N MODULE HEIGHT
VCAT S SHPG 1.0000 N SHIPPING GROUP
04 0 0 HC02 1 M 0151
W2F721B
BL
A
REV
ORDER TYPE
SO
BUSINESS UNIT
LEXLEXLexington
S N
PCODE
VAL-DATE
09/19/2003 11:02:11
PIC-DATE
09/19/2003 11:02:36
FEED MFG-DATE
10/08/2003 09:53:43
BACKWARD DATE
01/01/0001 00:00:00
INCLUDED ECNS
TYPE RULE CATG CODE SPC DESCRIPTION
FCAT O MODU HCOL N HORIZONTAL COIL MODULE
FCAT S MSIZ M N MEDIUM COIL MODULE
FCAT S SHIP EDLD N AIR ENT-STD / AIR LVG-STD
FCAT S INSL BS15 N 2" DW SOLID
FCAT O DPAN SSPR N PITCHED W/RH CONN IAQ PAN SST
FCAT S CHGT U N UNIT COIL
FCAT S DSEQ F N PHASE II MP580
FCAT O CSUP RH N RIGHT SIDE COIL CONN OR PIPE CAB
FCAT O CAPP CW N COOLING
FCAT S SYS CW N CHILLED WATER
FCAT O STRM UP N UPSTREAM - DRAW THRU
VCAT O EDBH 81.000 N Entering dry bulb VCAT O EWBH 62.000 N Entering wet bulb VCAT O LDBH 52.000 N Leaving dry bulb VCAT O LWBH 50.630 N Leaving wet bulb VCAT O TCAP 604.31 N Total capacity VCAT O SCAP 604.31 N Sensible capacity FCAT O HRN1 NONE N HR #1 not present FCAT O HRN2 NONE N HR #2 not present FCAT O HRN3 NONE N HR #3 not present
VCAT O LGTH 16.000 N MODULE LENGTH
VCAT O WGHT 817.60 N MODULE WEIGHT
VCAT O WDTH 113.00 N MODULE WIDTH
VCAT O HGTH 68.000 N MODULE HEIGHT
VCAT S SHPG 1.0000 N SHIPPING GROUP
POS COIL SEQ PRODUCT GROUP QTY HEADER TYPE PROD CODE
04 1 0 CL16 1 M 0151
TYPE RULE CATG CODE SPC DESCRIPTION
FCAT S CTYP UW N Type UW Coil Heating/Cooling-Water FCAT S CROW 4 N 4 Row VCAT S FSPG 156 N Coil Fin Spacing FCAT S FTYP DH N Delta Flow H High Efficiency FCAT S FMTL A N Aluminum Fins FCAT S TMTL 016C N .016" CU Std-Uint 1/2 OD Tube FCAT S CCSG SS N Stainless Steel
POS COIL SEQ PRODUCT GROUP QTY HEADER TYPE PROD CODE
04 1 1 CL04 1 M 0151
TYPE RULE CATG CODE SPC DESCRIPTION
FCAT S MODL DB N TRANE HTG/CLG STD COILS
FCAT S DSEQ D N DESIGN SEQUENCE "D",ELKHART
FCAT S CTYP UW N TYPE UW COIL HTG/CLG WATER
FCAT S CAPP CW N COOLING W/ DRAIN HOLES
FCAT S PCOD UTCC N UNIT TSCA P/C 0151 - "U" COIL WITH 2(2R FIN) OR
8(2-8R FIN) ROW CSG
FCAT S CSUP RH N RIGHT HAND - SIDE CONN HORIZ
FCAT S CCSG SSM N SST 8 ROW CSG U COIL
FCAT S CROW 4 N 4 ROW
VCAT S FWTH 57 N COIL FINNED WIDTH
VCAT S FLGH 99 N FINNED LENGTH
FCAT S FTYP DH N DELTA FLO H HIGH EFFICIENCY
FCAT S FMTL A N ALUMINUM FINS
VCAT S FSPG 156 N COIL FIN SPACING
FCAT S TMTL 016C N .016" CU STD-UNIT 1/2 OD TUBE
W2F721B
BL
A
REV
ORDER TYPE
SO
BUSINESS UNIT
LEXLEXLexington
S N
PCODE
VAL-DATE
09/19/2003 11:02:11
PIC-DATE
09/19/2003 11:02:36
FEED MFG-DATE
10/08/2003 09:53:43
BACKWARD DATE
01/01/0001 00:00:00
INCLUDED ECNS
05 0 0 AC02 1 M 0151
TYPE RULE CATG CODE SPC DESCRIPTION
FCAT S MODU ACC N ACCESS MODULE
FCAT S MSIZ M N MEDIUM ACCESS/BLANK MODULE
FCAT S SHIP EDLD N AIR ENT-STD / AIR LVG-STD
FCAT S INSL BS15 N INSULATION 2" DW SOLID
FCAT O ADOR R N RIGHT HAND DOOR
FCAT O LGHT ML N MARINE LIGHT
FCAT S DSEQ A N FIRST SHIP
FCAT O HRN1 NONE N HR #1 not present FCAT O HRN2 NONE N HR #2 not present FCAT O HRN3 NONE N HR #3 not present
VCAT O LGTH 16.000 N MODULE LENGTH
VCAT O WGHT 228.00 N MODULE WEIGHT
VCAT O WDTH 113.00 N MODULE WIDTH
VCAT O HGTH 68.000 N MODULE HEIGHT
VCAT S SHPG 1.0000 N SHIPPING GROUP
POS COIL SEQ PRODUCT GROUP QTY HEADER TYPE PROD CODE
06 0 0 FN02 1 M 0151
TYPE RULE CATG CODE SPC DESCRIPTION
FCAT S MODU FAN N T-SERIES FAN MODULE
FCAT O SPEC SPEC Y SPECIAL OPTION (SEE NOTES)
FCAT S SHIP EDLE N AIR ENT-STD / AIR LVG-EOU
FCAT S INSL BS15 N INSULATION 2" DW SOLID
FCAT S ADOR L N DOOR LEFT HAND
FCAT O DGRD DGRD N ACCESS DOOR GUARD
FCAT O LGHT ML N MARINE LIGHT
FCAT S FSIZ 40P N 39.38" AF - CHICAGO BLOWER
FCAT O WBAL IB N INVERTER BALANCE
FCAT S ISOL SPRG N SPRING ISOLATION
FCAT S RALO HS N HORIZONTAL SUPPLY FAN
FCAT S DCHG SPEC Y SPECIAL
FCAT S DRLO L N DRIVE LEFT HAND
FCAT S DSFT 1.5F N 1.5 FIXED DRIVE
FCAT S MSHP 25 N 25 HORSEPOWER
FCAT S MCIS EEOP N ODP HIGH EFF E+
FCAT S MVLT 460 N VOLTAGE 460/60/3
FCAT S MFRM T N T-FRAME MOTOR
FCAT S CYCL 60 N 60 CYCLE MOTOR
FCAT O NEMA VFDB N SQUARE D VAR FREQ DRIVE W/BP
FCAT S DSEQ E N LINE FEED STR PLT CHNG
VCAT S FCFM 19000 N FAN CFM
VCAT S RPMF 981 N FAN RPM
VCAT S BHPF 18.833 N FAN MOTOR BHP
VCAT O TSP 3.9000 N FAN TSP
FCAT S EXGL BOTH N GREASE LINE ON BOTH SIDES
FCAT O HRN1 NONE N HR #1 not present FCAT O HRN2 NONE N HR #2 not present FCAT O HRN3 NONE N HR #3 not present
VCAT O LGTH 62.000 N MODULE LENGTH
VCAT O WGHT 3687.2 N MODULE WEIGHT
VCAT O WDTH 113.00 N MODULE WIDTH
VCAT O HGTH 68.000 N MODULE HEIGHT
VCAT S SHPG 1.0000 N SHIPPING GROUP
W2F721B
BL
A
REV
ORDER TYPE
SO
BUSINESS UNIT
LEXLEXLexington
S N
PCODE
VAL-DATE
09/19/2003 11:02:11
PIC-DATE
09/19/2003 11:02:36
FEED MFG-DATE
10/08/2003 09:53:43
BACKWARD DATE
01/01/0001 00:00:00
INCLUDED ECNS
***** PARTS LIST *****
POS COIL SEQ PRODUCT GROUP QTY HEADER TYPE PROD CODE
AA 0 0 CC02 1 B 0151
PARENT
NUMBER
COMPONENT
PART NUMBER ITEM VER OPT PART DESCRIPTION QTY Special
000000000005 299881650000 001 01 0001 TSCX MODULE LENGTH 1.000
29981237GOMS 299812370012 001 00 0120 STIFFENER #40 3.000
29982187SHIP 299821870400 001 01 0010 SEAM CAPS AND CAULK
CASING
12.875
29982189SHIP 299821890400 001 00 0010 SUPT,ROOF 1.000
29982191SHIP 299821910400 001 00 0020 ROOF STRIP JOINT 5.598
29982193BASE 299821930020 001 00 0060 LIFT LUG,#35-50 6.000
299839010100 299839010400 001 00 0010 CURB,UNIT END 2.000
299839020100 299839020400 001 00 0010 CURB;UNIT SIDE 257.500
299839080100 299839080010 001 00 0010 CURB;ECON MODULE (VERT
RET)
1.000
29987622SHIP 299876220400 001 00 0010 CORNER SEAM CAP 1.000
299880510001 299880510200 001 00 0020 WEIGHT INNER ROOF # 613.361
299880520001 299880520100 001 00 0010 WEIGHT OUTER ROOF # 476.452
299880530001 299880530300 001 00 0030 WEIGHT BASE RAIL # 235.559
299880540001 299880540200 001 00 0020 WEIGHT WIRE CHASE # 114.139
POS COIL SEQ PRODUCT GROUP QTY HEADER TYPE PROD CODE
01 0 0 FN02 1 M 0151
PARENT
NUMBER
COMPONENT
PART NUMBER ITEM VER OPT PART DESCRIPTION QTY Special
000000000005 299881650000 001 01 0010 TSCX MODULE LENGTH 1.000
000000000100 296301150010 020 00 0010 NAMEPLATE 1.000
29191069GOMS 291910690001 020 00 A010 METHOD SHEET VFD #35-50
DRV 3
1.000
29191203GOMS 291912030001 000 02 0001 DOOR SWITCH 3-100 1.000
29191222SHIP 291912220106 020 00 A170 VFD PANEL 58 1.000
29191223SHIP 291912230003 010 00 A180 VFD TRANSFORMER 1.000
29191246GOMS 291912460001 010 00 A010 TINNERMAN CLIP MOUNTING 1.000
29191250SHIP 291912500467 020 00 P050 SCHEMATIC:VFD
RETURN/EXHAUST 12-100
DRIVE 3 W/BYPASS
WO/POWER ISOLATION 100VA
1.000
291912540100 291911510012 012 01 0010 MARINE LIGHT 1.000
2998LEFTDOOR 291912280036 C00 00 0080 INV BOX DR WLD LH #40 DV3 1.000
299800780200 299800780002 001 00 0020 PNL;DCHG EOU NO OPN 40C
FT/BK
1.000
29981000SHIP 299839670400 001 00 0020 CHNL,VERT SUPT SPLIT/EOU 2.000
29982193BASE 299821930020 001 00 0030 LIFT LUG,#35-50 2.000
29987615BASE 299876150400 CHN 00 0030 ISOL SUPT CHNL 1.000
29989501BASE 299895010400 000 00 0000 BOTTOM PANEL 1.000
2999CHNLBASE 299892060400 000 00 0000 CHNL, BASE EOU 1.000
2999LEFTDOOR 299904670400 001 03 0010 DOOR; ASY LH 1.000
440605201900 440601500024 010 00 C010 OMS;WIRE CONDUCTOR SZ 1.000
440605201900 440601500025 020 00 C010 OMS;WIRE TERMINATION 1.000
440605201900 440601500026 030 00 C010 OMS;9 LEAD MTR TERM 1.000
440605201900 440601500027 030 00 C020 OMS;9 LEAD MTR TERM 1.000
440605201900 440601500028 030 00 C030 OMS;9 LEAD MTR TERM 1.000
440605201900 440601500029 030 00 C040 OMS;6 LEAD MTR TERM 1.000
440605201900 440601500030 030 00 C050 OMS;3 LEAD MTR TERM 1.000
440605201900 440601500031 030 00 C060 OMS;6 LEAD MTR TERM 1.000
440605201900 440601830010 040 00 C010 HRDW;STR/VFD 1.000
W2F721B
BL
A
REV
ORDER TYPE
SO
BUSINESS UNIT
LEXLEXLexington
S N
PCODE
VAL-DATE
09/19/2003 11:02:11
PIC-DATE
09/19/2003 11:02:36
FEED MFG-DATE
10/08/2003 09:53:43
BACKWARD DATE
01/01/0001 00:00:00
INCLUDED ECNS
440605201900 440602030010 050 00 C010 HRDW;9 LEAD MTR TERM 1.000
440605201900 440602040010 050 00 C020 HRDW;3/6 LEAD MTR TERM 1.000
440605201900 440602230010 050 00 C030 HRDW;9 LEAD MTR TERM 1.000
999880550001 299880550100 001 00 0000 WEIGHT OUTER SIDE PANELS
33.161
999880560001 299880560100 001 00 0000 WEIGHT INNER SIDE PANELS # 34.317
999900010001 ZABFANTBI040 001 01 0240 LABOR FAN BI 40 1.000
999900010001 ZABHOUFAN355 009 00 0040 LABOR BASIC MODU 35-50 1.000
999900010001 ZABALLDOR355 015 00 0040 LABOR;ACCESS DOOR 35-50 1.000
999900010001 ZABMARFAN000 030 00 0040 MARINE LIGHT 3-100 1.000
999900010001 ZABVFDFAN350 038 00 0040 LABOR PARTS NUMBER 1.000
POS COIL SEQ PRODUCT GROUP QTY HEADER TYPE PROD CODE
02 0 0 EM02 1 M 0151
PARENT
NUMBER
COMPONENT
PART NUMBER ITEM VER OPT PART DESCRIPTION QTY Special
000000000020 299881650000 001 01 0004 TSCX MODULE LENGTH 1.000
000000000100 296301150010 020 01 0000 NAMEPLATE 1.000
291912530100 291911510012 012 01 0001 MARINE LIGHT 1.000
29984273HOOD 299812070001 001 00 0010 HOOD,ASY SIDE 40 1.000
29984273HOOD 299812070001 001 00 0020 HOOD,ASY SIDE 40 1.000
29984273HOOD 299819580001 001 00 0050 HOOD,ASY SIDE 40 1.000
299842730100 299842730001 001 01 0010 PNL ASY OUTSIDE AIR 40 1.000
299842730100 299842730002 001 00 0020 DAMPER PARL 40 1.000
299842730100 299842730002 001 00 0030 DAMPER PARL 40 1.000
299842730100 299842730003 001 00 0040 DAMPER PARL 40 1.000
299842730100 299842730003 001 00 0050 DAMPER PARL 40 1.000
299842730100 299842730007 001 01 0110 SCREW/BUTYL TAPE 40 1.000
29989551BASE 299895510400 001 00 0010 BOTTOM PANEL 1.000
2999RGHTDOOR 299890750400 001 00 0010 DOOR; RH 1.000
999900010001 ZABDMPALL355 002 00 0040 LABOR PARTS NUMBER 57.870
999900010001 ZABDMPALL355 005 00 0040 LABOR PARTS NUMBER 57.870
999900010001 ZABECNOUT355 008 00 0040 ECONOMIZER BASIC MODU 35-
1.000
999900010001 ZABALLDOR355 009 00 0040 LABOR;ACCESS DOOR 35-50 1.000
999900010001 ZABDMPALL355 016 00 0040 LABOR PARTS NUMBER 57.870
999900010001 ZABMARLGT000 019 00 0040 MARINE LIGHT 3-100 1.000
999900010001 ZABOAIHES355 020 00 0040 LABOR;OA INLET HOOD SID 35-
1.000
999900010001 ZABDMPALL355 025 00 0040 LABOR PARTS NUMBER 51.120
POS COIL SEQ PRODUCT GROUP QTY HEADER TYPE PROD CODE
03 0 0 FA02 1 M 0151
PARENT
NUMBER
COMPONENT
PART NUMBER ITEM VER OPT PART DESCRIPTION QTY Special
000000000100 296301150010 002 01 0000 NAMEPLATE 1.000
000000000100 299881650000 030 01 0002 TSCX MODULE LENGTH 1.000
2998BPNLBASE 299897680400 FLT 00 0010 BOTTOM PANEL 1.000
29981100SHIP 291801060400 001 00 0020 FILT;PM 2" 1.000
29989441GOMS 299894410400 001 00 0010 FILT FRAME ASSY 2" FLAT 1.000
2999RGHTDOOR 299897700400 001 00 0030 DOOR ASSY RH 1.000
999880550001 299880550100 001 00 0000 WEIGHT OUTER SIDE PANELS
6.151
999880560001 299880560100 001 00 0000 WEIGHT INNER SIDE PANELS # 7.920
999900010001 ZABFLAFLT355 002 00 0040 LABOR ANGLED FRAME 35-50 1.000
999900010001 ZABALLDOR355 004 00 0040 LABOR;ACCESS DOOR 35-50 1.000
W2F721B
BL
A
REV
ORDER TYPE
SO
BUSINESS UNIT
LEXLEXLexington
S N
PCODE
VAL-DATE
09/19/2003 11:02:11
PIC-DATE
09/19/2003 11:02:36
FEED MFG-DATE
10/08/2003 09:53:43
BACKWARD DATE
01/01/0001 00:00:00
INCLUDED ECNS
04 0 0 HC02 1 M 0151
PARENT
NUMBER
COMPONENT
PART NUMBER ITEM VER OPT PART DESCRIPTION QTY Special
000000000022 299881650000 001 01 0002 TSCX MODULE LENGTH 1.000
000000000100 296301150010 002 01 0000 NAMEPLATE 1.000
29980328BASE 291817510400 001 00 0040 DRAIN PAN;SST MED 1.000
29980328SHIP 299803280006 001 00 0010 COIL END PNL 40 UC 1.000
299803280100 299803280001 001 00 0010 BLKOFF;PRTS 40 UC 1.000
29992056BASE 299904120011 100 00 0120 ANGLE;DPAN CLIPS 4.000
29992072BASE 299904110003 100 00 0140 ANGLE; DPAN SUPT 1.000
999880550001 299880550100 001 00 0000 WEIGHT OUTER SIDE PANELS
8.558
999880560001 299880560100 001 00 0000 WEIGHT INNER SIDE PANELS # 10.051
999900010001 ZABHORCOL355 002 00 0040 LABOR;HORZ COIL MOD 35-50 1.000
POS COIL SEQ PRODUCT GROUP QTY HEADER TYPE PROD CODE
04 1 1 CL04 1 M 0151
PARENT
NUMBER
COMPONENT
PART NUMBER ITEM VER OPT PART DESCRIPTION QTY Special
284200000025 284101403002 400 00 E002 ASSY;COIL HDR/TUBE ARR 1.000
284200000105 284103010216 010 01 E063 SUPPORT; END LH 2 & 8 ROW 1.000
284200000105 284103000216 020 01 E063 SUPPORT; END RH 2 & 8 ROW 1.000
284200000105 284100400216 020 01 G000 SUPPORT; END - MATL 2103.194
284200000205 284103050216 030 01 E010 CHANNEL; SIDE W/ DRAIN
HOLES
2.000
284200000205 284100430216 040 00 G001 CHANNEL;SIDE - MATERIAL 1397.715
284200000205 284100430216 040 00 G002 CHANNEL;SIDE - MATERIAL 1397.715
284200000250 284100510100 050 00 G000 STRIP; FOAM - MATERIAL 194.760
284200000355 284103020216 060 01 E030 SUPPORT; CENTER 2 & 8 ROW 2.000
284200000355 284100420216 060 00 G000 SUPPORT; CENTER -
MATERIAL
1478.141
284200000355 284100180216 065 00 E030 ANGLE; CENTER SUPPORT 8.000
284200000450 284100770201 070 00 0000 SCREW; 1/4 X 1/2 HEX HD T.C. 20.000
284200000520 284104080357 110 00 E002 HEADER; SUPPLY/RETURN 2.000
284200000520 284100140500 140 00 E007 ADAPTER; 2.000
284200000520 284103532100 150 01 E008 HEADER;SPLY/RET&CAP(EXT) 2.000
284200000520 284100212157 170 00 E010 HEADER;MATL 2.000
284200000560 284100590112 500 01 E010 PROTECTOR; THREAD 2.000
284200000570 284100600310 230 00 0300 PLUG; 2.000
284200001200 284100360107 911 00 E100 U-TUBE; 1/2" ; PART CALLOUT 90.000
284200001200 284104020107 911 00 M100 U-TUBE; 1/2" MATERIAL (FEET)
- TOTAL FOR COIL
1548.510
284200001200 284104040123 936 00 E000 STUB; 1/2" 90.000
284200001200 284104030121 946 00 E000 U-BEND; 1/2" 90.000
284200001700 284100370841 600 00 E000 FIN; 1/2" TUBE 1281.000
284200001700 284100470841 600 00 M000 FIN; MATERIAL 255.785
284200001800 284100610001 700 00 E100 LABEL; TOP W/ARROW & INSP 1.000
284200001800 284100610003 700 00 E300 LABEL; AHRI 410 1.000
POS COIL SEQ PRODUCT GROUP QTY HEADER TYPE PROD CODE
05 0 0 AC02 1 M 0151
PARENT
NUMBER
COMPONENT
PART NUMBER ITEM VER OPT PART DESCRIPTION QTY Special
00000000TEST 291911890001 010 00 P010 COVER; ACCESS ROOF 1.000
000000000005 299881650000 002 01 0002 TSCX MODULE LENGTH 1.000
000000000100 296301150010 002 01 0000 NAMEPLATE 1.000
291912530100 291911510012 012 01 0001 MARINE LIGHT 1.000
2998BPNLBASE 299890590400 MED 00 0010 BOTTOM PANEL 1.000
2999RGHTDOOR 299890750400 001 00 0030 DOOR; RH 1.000
W2F721B
BL
A
REV
ORDER TYPE
SO
BUSINESS UNIT
LEXLEXLexington
S N
PCODE
VAL-DATE
09/19/2003 11:02:11
PIC-DATE
09/19/2003 11:02:36
FEED MFG-DATE
10/08/2003 09:53:43
BACKWARD DATE
01/01/0001 00:00:00
INCLUDED ECNS
999880550001 299880550100 001 00 0000 WEIGHT OUTER SIDE PANELS
8.558
999880560001 299880560100 001 00 0000 WEIGHT INNER SIDE PANELS # 10.051
999900010001 ZABACCSEC355 002 00 0004 LABOR;BASIC MODU 35-50 1.000
999900010001 ZABALLDOR355 003 00 0004 LABOR;ACCESS DOOR 35-50 1.000
999900010001 ZABMARLGT000 008 00 0004 MARINE LIGHT 3-100 1.000
POS COIL SEQ PRODUCT GROUP QTY HEADER TYPE PROD CODE
06 0 0 FN02 1 M 0151
PARENT
NUMBER
COMPONENT
PART NUMBER ITEM VER OPT PART DESCRIPTION QTY Special
000000000005 299881650000 001 01 0010 TSCX MODULE LENGTH 1.000
000000000100 296301150010 020 00 0020 NAMEPLATE 2.000
291803861601 291819380400 160 00 D010 BASE;ASY FAN P 1.000
291803862100 291821460400 210 00 P000 FAN;ASY 2700 PLUG FAN 1.000
291803862100 291821470400 210 00 Q000 CONE;INLET PLUG FAN 1.000
291803862120 291803320400 212 00 0000 BRG;HVY PLUG FAN 1.000
291803862150 291802420010 215 00 S000 TIGHTNR;PRTS 1.000
291803863030 291811100250 300 01 B030 MTR;T F1 EEOP230/460/3 1.000
291803863100 291802220010 310 00 0010 DRIVE KIT 1.000
29191070GOMS 291910700001 020 00 A010 METHOD SHEET VFD #35-50
DRV 4
1.000
29191170BASE 291911700001 001 00 0010 1" NIPPLE 6" PLATE 1.000
29191170BASE 291911700002 001 00 0020 1" BUSHING 1.000
29191172BASE 291911720001 001 01 0010 1" NIPPLE 6" PLATE 1.000
29191172BASE 291911720002 001 01 0020 1" BUSHING 1.000
29191203GOMS 291912030001 000 02 0001 DOOR SWITCH 3-100 1.000
29191222SHIP 291912220111 020 00 A220 VFD PANEL 58 1.000
29191223SHIP 291912230003 010 01 A030 VFD TRANSFORMER 1.000
29191246GOMS 291912460001 010 00 A010 TINNERMAN CLIP MOUNTING 1.000
29191250SHIP 291912500480 020 00 N060 SCHEMATIC:VFD HS 17-100
DRIVE 4 W/BYPASS
WO/POWER ISOLATION 100VA
TRANSF
1.000
291912540100 291911510012 012 01 0010 MARINE LIGHT 1.000
2998LEFTDOOR 291912280046 D00 00 0060 INV BOX DR WLD LH #40 DV4 1.000
29981000SHIP 299839670400 001 00 0020 CHNL,VERT SUPT SPLIT/EOU 2.000
29981057GOMS 299810570002 001 00 0020 THRUST REST 35-50P 1.000
29981587SHIP 299815870006 001 00 0060 PNL INLET CNTR 40P 1.000
29981587SHIP 299815870002 000 00 0000 PNL DCHG EDU NO OPN 40P 1.000
2999RGHTDOOR 293126920001 000 00 0000 DOOR FRAME;#35/40 W/O
DOOR PNL
1.000 Y
299815870100 299815870001 001 00 0010 FAN ASY 40P 1.000
29982181GOMS 299821810001 001 00 0030 ISOL TIEDOWN 35-50 1.000
29982193BASE 299821930020 001 00 0030 LIFT LUG,#35-50 2.000
29987615BASE 299876150401 CHN 01 0040 ISOL SUPT CHNL 1.000
29988200SHIP 299882000400 001 00 0010 DOOR SCREEN 1.000
29989509BASE 299895090400 BLK 00 0110 BOTTOM PANEL 1.000
2999CHNLBASE 299890510400 001 00 0162 CHNL; BASE EOU 1.000
2999LEFTDOOR 299904670400 001 03 0010 DOOR; ASY LH 1.000
440605201900 440601500024 010 00 C010 OMS;WIRE CONDUCTOR SZ 1.000
440605201900 440601500025 020 00 C010 OMS;WIRE TERMINATION 1.000
440605201900 440601500026 030 00 C010 OMS;9 LEAD MTR TERM 1.000
440605201900 440601500027 030 00 C020 OMS;9 LEAD MTR TERM 1.000
440605201900 440601500028 030 00 C030 OMS;9 LEAD MTR TERM 1.000
440605201900 440601500029 030 00 C040 OMS;6 LEAD MTR TERM 1.000
440605201900 440601500030 030 00 C050 OMS;3 LEAD MTR TERM 1.000
440605201900 440601500031 030 00 C060 OMS;6 LEAD MTR TERM 1.000
W2F721B
BL
A
REV
ORDER TYPE
SO
BUSINESS UNIT
LEXLEXLexington
S N
PCODE
VAL-DATE
09/19/2003 11:02:11
PIC-DATE
09/19/2003 11:02:36
FEED MFG-DATE
10/08/2003 09:53:43
BACKWARD DATE
01/01/0001 00:00:00
INCLUDED ECNS
440605201900 440601830010 040 00 C010 HRDW;STR/VFD 1.000
440605201900 440602030010 050 00 C010 HRDW;9 LEAD MTR TERM 1.000
440605201900 440602040010 050 00 C020 HRDW;3/6 LEAD MTR TERM 1.000
440605201900 440602230010 050 00 C030 HRDW;9 LEAD MTR TERM 1.000
999880550001 299880550100 001 00 0000 WEIGHT OUTER SIDE PANELS
33.161
999880560001 299880560100 001 00 0000 WEIGHT INNER SIDE PANELS # 34.317
999900010001 ZABFNTPLG040 001 01 0270 LABOR PLUG FAN 40 1.000
999900010001 ZABACCDRG000 003 00 0020 LABOR PARTS NUMBER 1.000
999900010001 ZABFANPLG355 010 00 0020 LABOR;FAN MODULE P-FAN 35-
1.000
999900010001 ZABALLDOR355 016 00 0020 LABOR;ACCESS DOOR 35-50 1.000
999900010001 ZABFANDFT355 025 01 0020 LABOR;FAN DCHG FRT-TOP 35-
1.000
999900010001 ZABMARFAN000 032 00 0020 MARINE LIGHT 3-100 1.000
999900010001 ZABVFDFAN350 039 00 0020 LABOR PARTS NUMBER 1.000
Trane Performance Climate Changer Air Handler
Unit Overview - AHU-2
Application Unit Size External Dimensions Weight
Height Width Length Installed Rigging Outdoor unit CSAA040 73.4 in 112.5 in 223.734 in 8147 lb 7873 lb
Quantity of Shipping Sections Largest Ship Split
Heaviest Ship Split Elevation Height Width Length
3 piece(s) 73.5 in 112.5 in 86.9 in 3674 lb 0.00 ft Supply Fan
Airflow 19000 cfm Total Static Pressure 3.900 in H2O Return/Exhaust Fan
Airflow 19000 cfm Total Static Pressure 2.031 in H2O
Note: Height includes air handler sloped roof panel and standing seam.
Construction Features
Panel 2in. foam injected R-13 with thermal break
Panel Material
All unit inner panels -galvanized
Integral Base Frame 6in. integral base frame
Paint Slate gray
Agency Approval UL listed unit
Unit Electrical
Circuit Voltage/Phase/Frequency FLA MCA Max Fuse Size SCCR
Circuit number 1 SPP (Field provided unit disconnect) 460/3/60 61.00 A 69.50 100.00 5 kA
Unit Controls Controller Type No controller
Warranty Warranty section Std. warranty only
CSAA
Quantity: 1 Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 1 of 29 Product Version: 1
Return fan section - Position: 1
Fan Data
Wheel Diameter/Type/Class 27in. dd plenum, full width, H press Fan Quantity 1
Discharge Location Front top Motor Location Right side drive
Blades Higher eff.(some bands lower,more spike)
Drive Service Factor Direct drive Fan K-factor 4156.00
FEI 0.80
Fan Performance
Airflow 19000 cfm Total Static Pressure 2.031 in H2O
Total Brake Power 15.512 hp Operating Speed 1997 rpm
AMCA FEG FEG85
Bare fan peak total efficiency 76.70 %
Unit Static Efficiency 39.23 %
Motor Interface Options
Selection Type VFD Voltage 460/3
Mounting Location Internal mounting VFD Frequency 68.00 Hz
Motor Data
Power / Fan 20 hp Voltage 460/3
Speed 1800 Class NEMA premium compliant ODP
Efficiency 93.17 % Part Load Efficiency 88.97 %
Fan electrical power (FEP) 12.81 kW Wire to air static efficiency 35.36 %
Note: Certified airflow performance per AHRI 430
Fan Section Options
Fan Wheel Balance Inverter balance with shaft grounding
Door Location Right Door Guard Yes
Fan Discharge Options
Face Type Airflow Face Velocity Area Pressure Drop Exhaust Hood Damper Torque
Requirement
Front Face Feature 469 ft/min 13.78 sq ft 0.034 in H2O N/A N/A
Side Face Feature Opposed blade damper 19000 cfm 1664 ft/min 11.42 sq ft 0.259 in H2O Side hood N/A
Note: Certified by the AHRI Central Station Air-Handling Unit (AHU) Certification Program, based on AHRI Standard 430/431. AHRI certified units are subject to rigorous and continuous testing, have performance ratings independently measured and are third party verified. Certified units may be found in the AHRI Directory at www.ahridirectory.org.
Pressure Drop in (in w.g.)
Return fan
Fan section 1.03
Internal Static Pressure 1.03
External Static Pressure 1.00
Total Static Pressure 2.03
Air mixing section - Position: 2
Openings
Face Path Type Airflow Face Velocity Area Pressure
Drop Hood
Back Return High velocity parallel damper
19000 cfm 2017 ft/min 9.42 sq ft 0.731 in H2O N/A
Right Outside High velocity opposed damper
9500 cfm 1004 ft/min 9.46 sq ft 0.459 in H2O Yes
Left Outside High velocity parallel damper
9500 cfm 1004 ft/min 9.46 sq ft 0.459 in H2O Yes
Section Options
Starter/VFD only section - Position: 3 Supply Fan Motor Interface Door Right
Return/Exhaust Fan Motor Interface Door Left
CSAA
Quantity: 1 Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 2 of 29
Filter section - Position: 4 Primary Filter
Type Frame Loading Airflow Face Area Face Velocity Condition Pressure
Drop Filter
Quantity Filter Size
Pleated media -
MERV 13
2in. filter frame
Side load filters 19000 cfm 40.83 sq ft 465 ft/min Mid-life 0.691 in
H2O
4.00 1.00 8.00 2.00
16x20 16x25 20x20 20x25
Filter Section Options
Door Location Right
Cooling coil section - Position: 5
Coil Construction
Model Chilled water - 1/2" Unit Optimized, High Water Flow(UU)
Rows 8 Tube Diameter 1/2in. tube diameter (12.7 mm)
Coil Connection Standard Tube Matl/Wall Thickness .016" (0.406 mm) copper tubes
Fin Spacing 84 Per Foot Fin Material Aluminum fins
Fin Type Delta flo H (Hi efficient) Face Area 39.93 sq ft
Coil (top/single) H x L 57 in. (1448 mm) X 100" (2540
mm) finned length
Casing Stainless steel Turbulators Not Included
Rigging Weight 636.9 lb Installed Weight 910.7 lb
Coil Section Options
Extended Drain and Vent Holes only Drain Pan Galvanized
Drain Pan Size Medium Drain Connection Left
Minimum Trap Height (L) 6.990 in H Trap Dimension 3.827 in J Trap Dimension 1.913 in
Door Location Right
Coil Performance
Capacity
Total 645.07 MBh Sensible 639.31 MBh
Air
Flow 19000 cfm Entering Dry Bulb 81.00 F Entering Wet Bulb 62.00 F Leaving Dry Bulb 50.27 F Leaving Wet Bulb 49.77 F
Pressure Drop 0.627 in H2O Face Velocity 476 ft/min
Fluid
Flow 128.55 gpm Entering 44.00 F Leaving 54.00 F
Pressure Drop 7.03 ft fluid Tube Velocity 2.45 ft/s
Reynolds Number 7048.00 Type Water
Fouling Factor 0.00000 hr-sq ft-deg F/Btu Volume 32.75 gal
AHRI 410 Classification
AHRI 410 Classification AHRI ACHC Certified Data Generation Date 2/23/2026
Trane Select Assist update number 26020
Note: Certified in accordance with the AHRI Forced-Circulation Air-Cooling and Air-Heating Coils Certification Program which is based on AHRI Standard 410 within the Range of Standard Rating Conditions listed in Table 1 of the Standard. Certified units may be found in the AHRI Directory at www.ahridirectory.org.
CSAA
Quantity: 1 Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 3 of 29
Supply fan section - Position: 6
Fan Data
Wheel Diameter/Type/Class 27in. dd plenum, full width, H press Fan Quantity 1
Discharge Location Front top Motor Location Right side drive
Blades Higher eff.(some bands lower,more spike)
Drive Service Factor Direct drive Fan K-factor 4156.00
FEI 1.02
Fan Performance
Airflow 19000 cfm Total Static Pressure 3.900 in H2O
Total Brake Power 21.669 hp Operating Speed 2139 rpm
AMCA FEG FEG85
Bare fan peak total efficiency 76.70 %
Unit Static Efficiency 53.91 %
Motor Interface Options
Selection Type VFD Voltage 460/3
Mounting Location Internal mounting VFD Frequency 73.00 Hz
Motor Data
Power / Fan 25 hp Voltage 460/3
Speed 1800 Class NEMA premium compliant ODP
Efficiency 93.67 % Part Load Efficiency 90.45 %
Fan electrical power (FEP) 17.80 kW Wire to air static efficiency 48.86 %
Note: Certified airflow performance per AHRI 430
Fan Section Options
Fan Wheel Balance Inverter balance with shaft grounding
Door Location Right Door Guard Yes
Fan Discharge Options
Face Type Airflow Face Velocity Area Pressure Drop Exhaust Hood Damper Torque
Requirement
Front Face Feature Sizeable rectangular opening
19000 cfm 1379 ft/min 13.78 sq ft 0.296 in H2O N/A N/A
Note: Certified by the AHRI Central Station Air-Handling Unit (AHU) Certification Program, based on AHRI Standard 430/431. AHRI certified units are subject to rigorous and continuous testing, have performance ratings independently measured and are third party verified. Certified units may be found in the AHRI Directory at www.ahridirectory.org.
Pressure Drop in (in w.g.)
Supply fan
Air mixing section 0.73
Filter section 0.69
Coil section 0.63
Fan section 0.30
Internal Static Pressure 2.35
External Static Pressure 1.55
Total Static Pressure 3.90
CSAA
Quantity: 1 Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 4 of 29
CSAA
Quantity: 1 Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 5 of 29
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 6 of 29 Product Version: 1
OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE Unit size: 40 Job Name: 163CES MARB AHU
Replacements Unit Casing: 2in Double Wall Foam
Performance Climate Changer Air Handlers
Product group: Outdoor unit 19000 cfm Proposal Number:
Integral base frame: 6in. integral base frame Sales Office: Tags: AHU-2 Paint: Slate gray 7873.3 lb / 8147.1 lb
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 7 of 29 Product Version: 1
OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES
ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE
Unit size: 40 Job Name: 163CES MARB AHU Replacements
Unit Casing: 2in Double Wall Foam
Performance Climate Changer Air Handlers
Product group: Outdoor unit 19000 cfm Proposal Number:
Integral base frame: 6in. integral base frame
Sales Office: Tags: AHU-2
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 8 of 29 Product Version: 1
OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES
ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE
Unit size: 40 Job Name: 163CES MARB AHU Replacements
Unit Casing: 2in Double Wall Foam
Performance Climate Changer Air Handlers
Product group: Outdoor unit 19000 cfm Proposal Number:
Integral base frame: 6in. integral base frame
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 9 of 29 Product Version: 1
OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES
ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE
Unit size: 40 Job Name: 163CES MARB AHU Replacements
Unit Casing: 2in Double Wall Foam
Performance Climate Changer Air Handlers
Product group: Outdoor unit 19000 cfm Proposal Number:
Integral base frame: 6in. integral base frame
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 10 of 29 Product Version: 1
OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES
ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE
Unit size: 40 Job Name: 163CES MARB AHU Replacements
Unit Casing: 2in Double Wall Foam
Performance Climate Changer Air Handlers
Product group: Outdoor unit 19000 cfm Proposal Number:
Integral base frame: 6in. integral base frame
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 11 of 29 Product Version: 1
OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE Unit size: 40 Job Name: 163CES MARB AHU
Replacements Unit Casing: 2in Double Wall Foam
Performance Climate Changer Air Handlers
Product group: Outdoor unit 19000 cfm Proposal Number:
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 12 of 29 Product Version: 1
OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE Unit size: 40 Job Name: 163CES MARB AHU
Replacements Unit Casing: 2in Double Wall Foam
Performance Climate Changer Air Handlers
Product group: Outdoor unit 19000 cfm Proposal Number:
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 13 of 29 Product Version: 1
OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE Unit size: 40 Job Name: 163CES MARB AHU
Replacements Unit Casing: 2in Double Wall Foam
Performance Climate Changer Air Handlers
Product group: Outdoor unit 19000 cfm Proposal Number:
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 14 of 29
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 15 of 29
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 16 of 29
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 17 of 29
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 18 of 29
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 19 of 29
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 20 of 29
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 21 of 29
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 22 of 29
Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 23 of 29
GENERAL
Outdoor air handling units will be shipped with all openings covered to protect unit interior from in-transit debris.
Installing contractor is responsible for long term storage in accordance with the Installation, Operation, and Maintenance manual (CLCH-SVX07*-EN).
Unit shall be UL and C-UL Listed.
Supply fans within the scope of AHRI Standard 430 are "Certified by the AHRI Central Station Air- Handling Unit (AHU) Certification Program, based on AHRI Standard 430/431. AHRI certified units are subject to rigorous and continuous testing, have performance ratings independently measured and are third-party verified. Certified units may be found in the AHRI Directory at www.ahridirectory.org".
Unit sound performance data shall be reported as sound power. Trane, in providing this program and data, does not certify or warrant NC levels. These levels are affected by factors specific to each application and/or installation and therefore unable to be predicted or certified by Trane. Refer to product data for specific fan footnote references.
Refer to product data for AHRI certification status. Propylene glycol and calcium chloride, or mixtures thereof, are outside the scope of AHRI Standard 410 and, therefore, do not require AHRI rating or certification. For coils within the scope of AHRI Standard 410 cooling coil performance is certified in accordance with the AHRI Forced-Circulation Air-Cooling and Air-Heating Coils Certification Program which is based on AHRI Standard 410 within the Range of Standard Rating Conditions listed in Table 1 of the Standard. Certified units may be found in the AHRI Directory at www.ahridirectory.org. Heating performance for heat pump or condenser mode is not certified.
Manufacturer provided VFDs shall be certified to AHRI Standard 1210 "Performance Rating of Variable Frequency Drives" to ensure documented and reliable VFD efficiency.
Unit Construction
Outdoor unit roofs shall incorporate a standing seam on the exterior to ensure a rigid roof construction and prevent water infiltration. Roof assembly shall overhang all walls by 1.5-inch minimum to prevent sheeting from roof to side panels. Rain gutters shall also be provided over all doors shorter than total unit height to direct rain away from the door assembly. Outdoor roofs shall be sloped, not less than
0.125 inches per foot, for water drainage. Where outdoor units are shipped in multiple sections, provide standing-seam joiners at each split with adhesive, hardware, and cover strips for field joining by the installing contractor.
All unit panels shall be 2" solid, double-wall construction to facilitate cleaning of unit interior. Unit panels shall be provided with a mid-span, no-through-metal, internal thermal break. Casing thermal performance shall be such that under 55°F supply air temperature and design conditions on the exterior of the unit of 81°F dry bulb and 73°F wet bulb, condensation shall not form on the casing exterior. Casing construction will comply with NFPA 90A.
All outdoor AHU interior casing panels will be made of galvanized steel.
Unit Paint
External surface of unit casing will be coated with water-based polyurethane paint. Color to be standard "Slate Gray". Factory-painted units will be able to withstand a salt spray test in accordance with ASTM B117 for a minimum of 500 consecutive hours and shall meet the following requirements following the salt-spray test:
- Mean scribe creepage rating of at least 6 per ASTM D1654 procedure A
- Blister size no larger than #6 per ASTM D714
- Blister density no greater than Medium per ASTM D714
- No onset of red rust
CSAA
Quantity: 1 Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 24 of 29
Casing Deflection The casing shall not exceed 0.0042 inch deflection per inch of panel span at 1.00 times design static pressure. Maximum design static shall not exceed +8 inches w.g. in all positive pressure sections and -8 inches w.g. in all negative pressure sections.
Floor Construction The unit floor shall be of sufficient strength to support a 300.0 lb load during maintenance activities and shall deflect no more than 0.0042 inch per inch of panel span.
Unit Base Manufacturer to provide a full perimeter integral base frame for either ceiling suspension of units or to support and raise all sections of the unit for proper trapping. Indoor unit base frame will either be bolted construction or welded construction. All outdoor unit base frames shall be welded construction.
For indoor units, refer to schedule for base height and construction type. Contractor will be responsible for providing a housekeeping pad when unit base frame is not of sufficient height to properly trap unit.
Unit base frames not constructed of galvanized steel shall be chemically cleaned and coated with both a rust-inhibiting primer and finished coat of rust-inhibiting enamel. Unit base height to be included in total height required for proper trap height.
Insulation Panel insulation shall provide a minimum thermal resistance (R) value of 13 ft²-h-ºF/Btu throughout the entire unit. Insulation shall completely fill the panel cavities in all directions so that no voids exist and settling of insulation is prevented.
Drain Pan In sections provided with a drain pan, the drain pan shall be designed in accordance with ASHRAE
62.1. To address indoor air quality (IAQ) the drain pan shall be sloped in two planes promoting positive drainage to eliminate stagnant water conditions. Drain pan shall be insulated, and of double wall construction. The outlet shall be the lowest point on the pan, and shall be of sufficient diameter to preclude drain pan overflow under normally expected operating conditions. All drain pans connections shall have a threaded connection, extending a minimum of 2-1/2" beyond the unit base, and shall be made from the same material as the drain pan. Drain pan located under a cooling coil shall be of sufficient size to collect all condensate produced from the coil.
Refer to Product Data for specific information on which sections are supplied with a drain pan, the drain pan material and connection location.
Access Door Construction Access doors shall be 2" double wall construction. Interior and exterior door panels shall be of the same construction as the interior and exterior wall panels respectively. All doors shall be provided with a thermal break construction of door panel and door frame. Gasketing shall be provided around the full perimeter of the doors to prevent air leakage. Surface mounted handles shall be provided to allow quick access to the interior of the functional section and to prevent through cabinet penetrations that could likely weaken the casing leakage and thermal performance. Handle hardware shall be designed to prevent unintended closure. Outswing doors shall have easily removable hinges and handles that can be relocated to change the door swing if needed. Door hinges shall be made of galvanzed steel.
All doors shall be a minimum of 60" high when sufficient height is available or the maximum height allowed by the unit height.
Door handles shall be provided for each latching point of the door necessary to maintain the specified air leakage integrity of the unit. An optional shatterproof window shall be provided in access doors where indicated on the plans. Window shall either be single pane, or thermal dual pane, as defined on schedule. Window shall be capable of withstanding unit operating pressures and shall be safe for viewing UV-C lamps.
Refer to Product Data for specific information on which sections are supplied with an access door, the door location, a single handle and a window.
CSAA
Quantity: 1 Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 25 of 29
Pier-mount Outdoor units to be mounted to a pier support system must have at a minimum one pier at each corner of the unit and every four feet at equally spaced intervals around the entire unit perimeter. In addition, if the unit has shipping split(s) a pier must be located under split point(s) on both sides of the unit, ensuring equal support to both sides of the unit split. Both the main unit, and optional external piping cabinet(s), require pier supports.
Single Point Power Options
For air handling units requiring both a supply and return/exhaust fan, the unit manufacturer shall supply single point power wiring to both factory installed and tested fan variable frequency drives.
Individual high voltage enclosures will be supplied for both the supply and return/exhaust fans. Single point power wiring shall include a high voltage distribution block located in the supply fan variable frequency drive cabinet. Single point power wiring shall not compromise the UL or ETL certification of the unit. Single point power wiring shall also include factory installed and wired control systems and lights if ordered.
Lifting Instructions The air handling units must be rigged, lifted, and installed in strict accordance with the Installation, Operation, and Maintenance manual (CLCH-SVX07G-EN). The units are also to be installed in strict accordance with the specifications. Units may be shipped fully assembled or disassembled to the minimum functional section size in accordance with shipping and job site requirements.
Outdoor units shall be shipped on frame for the purpose of mounting units on a roof curb or field-supplied pier support system. Refer to the Product Data section for type of the base frame provided (for roof curb or pier-mount).
All units will be shipped with an integral base frame designed with the necessary number of lift points for safe installation. All lifting lugs are to be utilized during lift. The lift points will be designed to accept standard rigging devices and be removable after installation.
MIXING SECTION
A mixing section shall be provided to support the damper assembly for outdoor, return, and/or exhaust air.
Inlet Hoods Inlet hoods are provided on the outside air openings and equipped with high performance moisture eliminators to minimize water carryover from the outside into the unit casing. Eliminators also perform the function of a bird screen to prevent nesting.
Refer to the unit As-Built and Product Data section for specific information on which sections are supplied with inlet hood.
Inlet Hoods Inlet hoods are provided on the outside air openings and equipped with high performance moisture eliminators to minimize water carryover from the outside into the unit casing. Eliminators also perform the function of a bird screen to prevent nesting.
Refer to the unit As-Built and Product Data section for specific information on which sections are supplied with inlet hood.
Dampers Dampers shall modulate the volume of outdoor, return, or exhaust air. The dampers shall be of double-skin airfoil design with metal, compressible jamb seals and flexible blade-edge seals on all blades. The blades shall rotate on stainless-steel sleeve bearings. The dampers shall be rated for a maximum leakage rate of 3 cfm/ft² at 1 in. w.g. complying with ASHRAE 90.1 maximum damper leakage. All leakage testing and pressure ratings shall be based on AMCA Standard 500-D. Dampers may be arranged in a parallel or opposed-blade configuration.
CSAA
Quantity: 1 Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 26 of 29
Dampers Dampers shall modulate the volume of outdoor, return, or exhaust air. The dampers shall be of double-skin airfoil design with metal, compressible jamb seals and flexible blade-edge seals on all blades. The blades shall rotate on stainless-steel sleeve bearings. The dampers shall be rated for a maximum leakage rate of 3 cfm/ft² at 1 in. w.g. complying with ASHRAE 90.1 maximum damper leakage. All leakage testing and pressure ratings shall be based on AMCA Standard 500-D. Dampers may be arranged in a parallel or opposed-blade configuration.
Dampers Dampers shall modulate the volume of outdoor, return, or exhaust air. The dampers shall be of double-skin airfoil design with metal, compressible jamb seals and flexible blade-edge seals on all blades. The blades shall rotate on stainless-steel sleeve bearings. The dampers shall be rated for a maximum leakage rate of 3 cfm/ft² at 1 in. w.g. complying with ASHRAE 90.1 maximum damper leakage. All leakage testing and pressure ratings shall be based on AMCA Standard 500-D. Dampers may be arranged in a parallel or opposed-blade configuration.
Mixing section inlet wall shall include removable panel to provide access to actuators for installation and service. Service panel to be accessible from the section immediately upstream of the mixing box.
Title 24 The following specifications apply only to units with outside air and return air dampers, with actuators.
The 5 year warranty applies only to these items.
This unit contains Economizer that meets or exceeds all mandatory requirements prescribed by Title 24, including but not limited to:
- 5 yr parts only warranty
- Successfully tested to 60,000 Actuations
- Less than 10 cfm/sq.ft. of damper leakage at 1" WG per AMCA 500L
FILTER SECTION
A section shall be provided to support the filter rack as indicated throughout the unit. Refer to Product Data and As-Built sections of the submittal for specific locations within each unit.
Primary Filters
2 inch pleated media filters made with 100% synthetic fibers that are continuously laminated to a supported steel wire grid with water repellent adhesive shall be provided. Filters shall be capable of operating up to 625 fpm face velocity without loss of filter efficiency and holding capacity. The filters shall have a MERV 13 rating when tested in accordance with the ANSI/ASHRAE Standard 52.2.
COIL SECTION WITH FACTORY INSTALLED COIL
The coil section shall be provided complete with coil and coil holding frame. The coils shall be installed such that headers and return bends are enclosed by unit casings. If two or more cooling coils are stacked in the unit, an intermediate drain pan shall be installed between each coil and be of the same material as the primary drain pan. Like the primary drain pan, the intermediate drain pan shall be designed being of sufficient size to collect all condensation produced from the coil and sloped to promote positive drainage to eliminate stagnant water conditions. The intermediate pan shall begin at the leading face of the water-producing device and be of sufficient length extending downstream to prevent condensate from passing through the air stream of the lower coil. Intermediate drain pan shall include downspouts to direct condensate to the primary drain pan. The outlet shall be located at the lowest point of the pan and shall be sufficient diameter to preclude drain pan overflow under any normally expected operating condition.
Coil with Inspection The coil section complete with a double-wall, shall include a removable door downstream of the coil for inspection, cleaning, and maintenance. Interior and exterior door panels shall be of the same construction as the interior and exterior wall panels, respectively. All doors shall be provided with a thermal break construction of door panel and door frame.
Casing penetrations supplied for hydronic drain and vents. Piping contractor shall provide extended piping.
Water Coils (UP, WP, UW, UU, UA, 3W, 3U, W, 5W, 5A, WD, 5D, D1, D2, P, or TT)
CSAA
Quantity: 1 Tags: AHU-2
Job Name: 163CES MARB AHU Replacements Generated By User: u234038
2026/02/24 18:05:00 Page 27 of 29
The coils shall have aluminum fins and seamless copper tubes. Copper fins may be applied to coils with 5/8-inch tubes.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .