This document provides details for a federal contract solicitation to replace an existing roof system at Wright Patterson Air Force Base in Ohio. The solicitation seeks to remove the built-up roof system and cap sheet from the 130,000 square foot commissary building and reconstruct the roof with a two-ply modified bitumen and granular surface. The project includes verifying the conditions of the metal decking and internal roof drains before installing the new roofing materials. The solicitation is identified as number HQC00324B0002 and is being conducted by the Defense Commissary Agency.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C:\Users\marcella.staniek\Desktop\-deca-logo-outline-609359.png
HMP
DHJ, HMP
RR
24 MARCH 2022
ROOF REPLACEMENT/ REPAIR DESIGN
WRIGHTS-PATTERSON AFB
COMMISSARY BUILDING , OHIO
TETRA TECH
Louisville, Kentucky 40222
(502) 569-9007
Suite 245 2000 Warrington Way
IF DRAWING IS NOT 30" X 42", SCALE ACCORDINGLY.
PROJECT NUMBER:
DIRECTORATE OF FACILITIES
FT. LEE, VIRGINIA
DESIGN AND CONSTRUCTION DIVISION
LACKLAND AFB, TEXAS
DEFENSE COMMISSARY AGENCY
DESIGNED BY:
DRAWN BY:
SUBMITTED BY:
ENGINEER:
REVIEWED BY:
DRAWING NUMBER:
SOL NUMBER:
OF
DATE:
SHEET:
SEQUENCE
NUMBER:
SYMBOL DATE DESCRIPTION OF REVISIONSACTIOND O NO
100% SUBMISSION - FOR CONSTRUCTION
EA21MR05
This electronic drawing file is released under the authority of Bill Nieport, TX # 23653 and Tetra Tech, TX # BR 594 who maintains a hard copy of the original file. The user of this electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file. No person may make any modification to this electronic drawing file without the
Architect's express written permission.
PRELIMINARY:
FOR INTERIM REVIEW
NOT FOR
CONSTRUCTION,
BIDDING OR PERMIT
PURPOSES
DATE:
TX LICENSE:
ARCHITECT :
TT FIRM REG. NO.
DHJ
RR 1 G-001
COVER SHEET
..\..\..\..\hope.pollonais\Downloads\AFB.PNG
INDEX OF DRAWINGS
SHEET NUMBER SHEET TITLE
GENERAL
G-001 COVER SHEET
ARCHITECTURAL
A-101
A-102
DEMOLITION ROOF PLAN
A-103
NEW ROOF PLAN
A104 WALK PAD ROOF PLAN
A-501
A-502
A-503 TYPICAL ROOF DETAILS
TYPICAL ROOF DETAILS
TYPICAL ROOF DETAILS
WIND ZONE ROOF PLAN
DECA PROJECT NO. EA21MR05
ROOF REPLACEMENT / REPAIR DESIGN
WRIGHTS-PATTERSON AFB COMMISSARY BUILDING
DEFENSE COMMISSARY AGENCY
DIRECTORATE OF FACILITIES, FORT LEE, VIRGINIA
DESIGN & CONSTRUCTION DIVISION, LACKLAND AFB, TEXAS
24 MARCH 2022
VICINITY MAP
LOCATION MAP
AREA MAP PROJECT LOCATION
NDRAWING NOTES
G-002 GENERAL NOTES AND LEGENDS
A. ALL CONSTRUCTION, ALTERNATIONS, MOVEMENT, ENLARGEMENT, REPLACEMENT AND REPAIR
WORK SHALL COMPLY WITH THE CURRENT EDITION AND REVISIONS OF THE 2012 INTERNATIONAL BUILDING CODE AND ANY APPLICABLE GEORGIA STATE AMENDMENTS, AS WELL AS LOCAL CODES.
B. ALL INSTALLATIONS OF NEW PLUMBING SHALL COMPLY WITH THE CURRENT EDITION AND
REVISIONS OF THE 2012 INTERNATIONAL PLUMBING CODE AND ANY APPLICABLE GEORGIA STATE
AMENDMENTS, AS WELL AS LOCAL CODES.
C. REFERENCE STANDARDS
ASTM - AMERICAN SOCIETY OF TESTING AND MATERIALS.
U.L. - UNDERWRITERS' LABORATORIES.
F.M. - FACTORY MUTUAL OR FACTORY MUTUAL RESEARCH CORPORATION.
SMACNA - SHEET METAL AND AIR CONDITIONING CONTRACTORS ASSOCIATION.
AIA - AMERICAN INSTITUTE OF ARCHITECTS.
NRCA - NATIONAL ROOFING CONTRACTOR ASSOCIATION.
IBC - INTERNATIONAL BUILDING CODE, 2021 EDITION
IPC - I2018 EDITION WITH 2020 GEORGIA STATE AMENDMENTS
REFER TO STRUCTURAL DRAWING FOR LOADING INFORMATION.
1. THESE NOTES ARE FOR THE GENERAL CONTRACTOR, AND ALL ASSOCIATED SUBCONTRACTORS, MANUFACTURERS, AND SUPPLIERS.
2. SHOULD A DISCREPANCY EXIST BETWEEN THE DRAWINGS AND SPECIFICATION, THE
CONTRACTOR AND/OR SUBCONTRACTOR SHALL MAKE MENTION TO THE ENGINEER FOR
DIRECTION PRIOR TO PROCEEDING WITH WORK.
3. ALL MEASUREMENTS AND EXISTING CONDITIONS MUST BE VERIFIED PRIOR TO ORDERING
MATERIALS AND PROCEEDING WITH WORK.
4. ALL CROSS-SECTIONAL DETAILS REPRESENT TYPICAL CONDITIONS, AND THOSE
CROSS-SECTIONAL DETAILS SHALL BE APPLIED IN MERIT TO APPLICABLE AREAS ON THE ROOF
EVEN THOUGH NOT SPECIFICALLY MARKED ON DRAWINGS OR REFERENCED IN
SPECIFICATIONS.
5. ALL MANUFACTURER'S RECOMMENDATIONS MUST BE STRICTLY ADHERED TO, UNLESS MORE
STRINGENT REQUIREMENTS LIE WITHIN THE SPECIFICATION OR DRAWINGS.
6. SOME DETAILS IN THESE DRAWINGS ARE PROVIDED BY COPPER B-LINE AND ZURN, INC.;
HOWEVER,THESE DETAILS ARE USED TO ESTABLISH A STANDARD OF QUALITY AND IN NO WAY
LIMIT THE CONTRACTOR TO PRODUCTS THAT MAY BE USED. REQUEST FOR COMPARABLE
PRODUCTS MUST BE APPROVED PRIOR TO BID.
GENERAL NOTES
N
HMP
DHJ, HMP
RR
24 MARCH 2022
ROOF REPLACEMENT/ REPAIR DESIGN
WRIGHTS-PATTERSON AFB
COMMISSARY BUILDING , OHIO
TETRA TECH
Louisville, Kentucky 40222
(502) 569-9007
Suite 245 2000 Warrington Way
IF DRAWING IS NOT 30" X 42", SCALE ACCORDINGLY.
PROJECT NUMBER:
DIRECTORATE OF FACILITIES
FT. LEE, VIRGINIA
DESIGN AND CONSTRUCTION DIVISION
LACKLAND AFB, TEXAS
DEFENSE COMMISSARY AGENCY
DESIGNED BY:
DRAWN BY:
SUBMITTED BY:
ENGINEER:
REVIEWED BY:
DRAWING NUMBER:
SOL NUMBER:
OF
DATE:
SHEET:
SEQUENCE
NUMBER:
SYMBOL DATE DESCRIPTION OF REVISIONSACTIOND O NO
100% SUBMISSION - FOR CONSTRUCTION
EA21MR05
This electronic drawing file is released under the authority of Bill Nieport, TX # 23653 and Tetra Tech, TX # BR 594 who maintains a hard copy of the original file. The user of this electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file. No person may make any modification to this electronic drawing file without the
Architect's express written permission.
PRELIMINARY:
FOR INTERIM REVIEW
NOT FOR
CONSTRUCTION,
BIDDING OR PERMIT
PURPOSES
DATE:
TX LICENSE:
ARCHITECT :
TT FIRM REG. NO.
DHJ
RR
GENERAL NOTES AND LEGENDS
A-1012
1. PERFORM ALL WORK IN COMPLIANCE WITH ALL APPLICABLE CODES, REGULATIONS, ORDINANCES AND
STANDARDS OF THE LOCAL BUILDING CODE AUTHORITY.
2. THE CONTRACTOR SHALL OBTAIN AND PAY FEES FOR ALL NECESSARY PERMITS, LICENSES, CERTIFICATES, TESTING, ETC.
3. THE CONTRACTOR SHALL REVIEW THE CONSTRUCTION DOCUMENTS AND SHALL BRING CONFLICTS AND/OR QUESTIONS TO THE ATTENTION OF THE ARCHITECT FOR RESOLUTION PRIOR TO THE COMMENCEMENT OF
CONSTRUCTION.
4. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING
CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.
5. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE.
6. THE CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES.
7. CONFIRM LOCATIONS OF STRUCTURAL MEMBERS PRIOR TO CUTTING HOLES IN ROOFS. DO NOT CUT HOLES IN STRUCTURAL MEMBERS BEFORE OBTAINING WRITTEN PERMISSION FROM THE STRUCTURAL ENGINEER OF
RECORD.
8. LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY.
9. IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDES A COMPLETE, FUNCTIONING PROJECT INCLUDING ALL GENERAL, MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED, REGARDLESS OF WHETHER OR NOT SHOWN
ON THE DRAWINGS.
10. WRITTEN DIMENSIONS GOVERN. DO NOT SCALE DRAWINGS. NOTIFY THE ARCHITECT IN THE EVENT THAT
REQUIRED DIMENSIONS ARE NOT GIVEN.
11. ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY THE CONTRACTOR ARE NOTED "N.I.C.".
12. "ALIGN" AS USED IN THESE DOCUMENTS, MEANS TO ALIGN THE FINISHED FACE OF THE ELEMENTS IN THE SAME
PLANE, EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING.
13. "SIMILAR" OR "SIM", AS USED IN THESE DOCUMENTS MEANS THAT THE ITEM OR DETAIL REFERENCED IS SUBSTANTIALLY THE SAME AS THE ITEM OR DETAIL BEING REFERRED TO, WITH MINOR VARIATIONS THAT DO NOT
AFFECT FUNCTION OR APPEARANCE.
14. "TYPICAL" OR "TYP", AS USED IN THESE DOCUMENTS MEANS THAT THE ITEM OR DETAIL REFERENCED IS THE SAME FOR ALL CONDITIONS OF A SIMILAR NATURE THROUGHOUT THE PROJECT, UNLESS NOTED OTHERWISE.
15. DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS. DRAWINGS ARE INTERRELATED.
16. CONTRACTORS SHALL VERIFY ALL DIMENSIONS IN FIELD. CONTRACTOR IS SOLELY RESPONSIBLE FOR
DIMENSIONAL TAKE-OFFS FOR THE PROJECT.
17. CONSTRUCTION AND CONSTRUCTION RELATED ACTIVITIES SHALL BE THOROUGHLY COORDINATED WITH THE OWNER AND SHALL NOT BLOCK EXISTING MEANS OF EGRESS. WORK SHALL BE PHASED SO THAT SAFE ACCESS TO AND EGRESS FROM THE BUILDINGS IS MAINTAINED AT ALL TIMES. SITE ACCESS SHALL BE AS ARRANGED
THROUGH THE OWNER.
18. UNANTICIPATED CONDITIONS ENCOUNTERED DURING THE COURSE OF THE WORK WHICH REQUIRE ADDITIONAL REPAIRS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER OR OWNER REPRESENTATIVE.
NO ADDITIONAL REPAIR WORK SHALL BE PERFORMED UNLESS APPROVED IN ADVANCE BY THE
ARCHITECT/ENGINEER AND OWNER.
19. THE DRAWINGS AND SPECIFICATIONS ARE TO BE TAKEN IN THEIR ENTIRETY AND AS A WHOLE. IF A DISCREPANCY IS FOUND BETWEEN THE DRAWINGS AND SPECIFICATIONS, THE ARCHITECT/ENGINEER SHALL HAVE THE OPTION
AS TO WHICH GOVERNS.
20. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL MEANS AND METHODS. PROCEDURES SHALL BE IN
ACCORDANCE WITH APPLICABLE BUILDING CODES AND STANDARDS.
21. CONTRACTOR SHALL PERFORM CLEAN-UP AND DEBRIS REMOVAL DAILY AND SHALL BE SATISFACTORY TO THE
OWNER.
22. THE CONTRACTOR SHALL PROVIDE DUMPSTERS AND DUMPSTER REMOVAL. LOCATE DUMPSTERS WHERE
DESIGNATED BY OWNER.
23. SPECIAL CONTROLS: THE CONTRACTOR SHALL INSTITUTE THE NECESSARY MEASURE TO PREVENT/MINIMIZE DUST, FUMES, ODORS, DEBRIS, OR LIQUIDS FROM THIS PROJECT FROM ENTERING NON-CONSTRUCTION AREAS OF THE BUILDING. THIS SHALL INCLUDE BUT NOT BE LIMITED TO: INSTALLATION OF PARTITIONS AND SEALANTS OVER ALL OPENINGS TO THE BUILDING; SEALING AND MAINTAINING SEALS ON ALL DOORS, EQUIPMENT ROOMS, OFFICES, CEILING AND FLOOR PENETRATIONS, ETC.; USE OF OPEN FLAMES, HIGHLY VOLATILE SOLVENTS, OR
NOXIOUS CHEMICALS WILL NOT BE PERMITTED.
23.1. NOISE CONTROL: THE CONTRACTOR SHALL CONFINE HIS HOURS OF OPERATION TO THOSE REQUIRED BY THE OWNER AND LOCAL LAWS AND ORDINANCES. NOISE LEVELS SHALL BE HELD TO A MINIMUM CONSIDERING THE NATURE OF THE WORK. DISRUPTIONS TO NORMAL BUILDING OPERATIONS SHALL BE
MINIMIZED.
23.2. DUST CONTROL: THE CONTRACTOR SHALL ERECT, AS REQUIRED, TEMPORARY ENCLOSURES TO
PREVENT DUST FROM ENTERING NON-WORK AREAS, DUCT WORK, ETC. THE CONTRACTOR SHALL
PROVIDE FOR PROTECTION FOR HIS EMPLOYEES FROM DUST ACCORDING TO OSHA AND
ENVIRONMENTAL AGENCIES HAVING JURISDICTION.
23.3. WATER CONTROL: THE CONTRACTOR SHALL NOT PERMIT WATER TO RUN UNCONTROLLED OFF OF HIS WORK OR BE CARRIED AIRBORNE OFF THE SITE OR ONTO VEHICLES AND PERSONS OCCUPYING PART OF THE SITE. TO PREVENT THIS, SUITABLE ENCLOSURES SHALL BE PROVIDED IF WATER OR MOISTURE
EXCEEDS LEVELS ACCEPTABLE TO THE OWNER.
23.4. CONTRACTORS SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT FIRE DURING THE WORK.
23.5. CONTRACTOR SHALL PROVIDE ALL NECESSARY EQUIPMENT, LABOR, MATERIALS, AND COMPONENTS
REQUIRED FOR THE TEMPORARY RELOCATION OF MECHANICAL/ELECTRICAL EQUIPMENT AND
PLUMBING LINES TO ALLOW FOR INSTALLATION OF THE NEW WORK, AND PROVIDING TEMPORARY
SERVICES ARE REQUIRED.
24. CONTRACTORS SHALL PROVIDE PROTECTION OF EXTERIOR WALL AND INTERIOR OF BUILDING AT ALL TIMES AGAINST ENTRY OF WATER, DUST, AND VERMIN DURING WORK. CONTRACTOR SHALL REPAIR ALL DAMAGE
CAUSED BY SUCH INFILTRATION DURING THE WORK AT NO COST TO THE OWNER.
25. THE ARCHITECT/ENGINEER OR OWNER REPRESENTATIVE MAY PERFORM QUALITY CONTROL TESTS ON A RANDOM BASIS TO EVALUATE INSTALLATION OF THE NEW CONSTRUCTION FOR CONFORMANCE TO THE DRAWINGS AND SPECIFICATIONS. THE CONTRACTOR SHALL MAKE ACCESS AVAILABLE AT NO ADDITIONAL COST FOR THE ARCHITECT/ENGINEER OR OWNER REPRESENTATIVE TO INSPECT AND TEST THE WORK AREAS AND SHALL MAKE APPROPRIATE REPAIRS AFTER COMPLETION OF SUCH INSPECTIONS. ANY DEFECTIVE WORK SHALL BE REPAIRED
AT NO ADDITIONAL COST TO THE OWNER.
ASCE 7-16 MINIMUM RECOMMENDED DESIGN WIND-RESISTANCE LOADS:
PERIMETER ROOF EDGE SECUREMENT
ZONE 2 (ROOF EDGE PERIMETER, VERTICAL LOAD DIRECTION):
ZONE 3 (ROOF EDGE CORNERS,VERTICAL LOAD DIRECTION):
ZONE 4 (WALL EDGE PERIMETER, HORIZONTAL LOAD DIRECTION):
ZONE 5 (WALL EDGE CORNERS, HORIZONTAL LOAD DIRECTION):
MINIMUM RECOMMENDED DESIGN UPLIFT-RESISTANCE CAPACITY
ZONE 11
ZONE 1
ZONE 2
ZONE 3
SEE A-103 FOR WIND ZONES ON ROOF PLAN
COMPONENT AND CLADDING WIND UPLIFT PRESSURES (non factored)
ASCE 7-16
ROOF AREA DIMENSIONS (FEET): REFER TO ROOF PLAN
MEAN ROOF HEIGHT FOR ROOFS VARIES
ROOF SLOPE: 1/4":12
RISK CATEGORY: II
BASIC WIND SPEED (THREE-SECOND PEAK GUST, MPH): 107 MPH
ROOF DECK TYPE: STEEL DECK
ROOF COVERING TYPE: MODIFIED BITUMEN
GENERAL
1. THE ROOFING CONTRACTOR SHALL VERIFY ALL CONDITIONS IN THE FIELD. THIS SHALL INCLUDE VERIFYING THE EXACT LOCATIONS, DIMENSIONS AND QUANTITIES OF ALL ROOFTOP EQUIPMENT AND APPURTENANCES WHICH INCLUDING, BUT IS NOT LIMITED TO VENT PIPES, DRAINS, FLUE PIPES, HOT STACK CURBS, BASE FLASHING AND ALL OTHER PENETRATIONS AND WORK ASSOCIATED WITH THIS ROOFING PROJECT. ROOFING CONTRACTOR SHALL NOTIFY OWNER, IN WRITING, OF ALL CONDITIONS WHICH ARE IN VARIANCE WITH THE CONDITIONS DOCUMENTED HEREIN PRIOR TO SUBMITTING A BID. AFTER AWARD NO ADDITIONAL COSTS TO OWNER WILL BE ACCEPTED.
2. LAYDOWN/STORAGE AREA IS LIMITED AND SHALL BE AS APPROVED BY THE OWNER
3. PRIOR TO PERFORMING WORK, CONTRACTOR SHALL INSPECT WORK SITE AND EXISTING CONSTRUCTION FOR
POTENTIAL SAFETY HAZARDS.PROVIDE FOR THE SAFETY AND PROTECTION OF WORKERS
4. BUILDING ACCESS IS RESTRICTED AND ALLOWED ONLY AS REQUIRED TO ACCOMPLISH CONTRACT WORK.
COORDINATE ANY REQUIRED ACCESS WITH OWNER.
5. SITE SHALL BE CLEANED AND SECURED ON A DAILY BASIS.
6. THE BUILDING MAY BE FULL OR PARTIALLY OCCUPIED; ROOFING CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL
MEANS AND METHODS OF CONSTRUCTION.
7. ROOFING CONTRACTOR SHALL PROTECT ALL EXISTING CONSTRUCTION TO REMAIN, INCLUDING GROUNDS, EXTERIOR SURFACES AND THE INTERIOR OF THE BUILDING. DAMAGE CONDITION BY THE CONTRACTOR SHALL BE REPAIRED AT NO ADDITIONAL COST TO THE OWNER. ALL REPAIR WORK MUST CONFORM TO THE ORIGINAL
CONDITIONS AND SATISFY TO THE OWNER AND ENGINEER OF RECORD.
8. ALL DETAILS INDICATE MINIMUM INSTALLATION REQUIREMENTS. IF THE MANUFACTURER'S STANDARD DETAILS ARE MORE STRINGENT, IN THE OPINION OF ENGINEER OF RECORD, THEY SHALL GOVERN. IF THE DETAILS SHOWN ARE MORE STRINGENT THAN THE MANUFACTURER'S STANDARD DETAILS, IN THE OPINION OF THE ENGINEER OF RECORD, THE DETAILS SHOWN SHALL GOVERN, REGARDLESS OF THE MANUFACTURER'S WILLINGNESS TO WARRANT / GUARANTY THE LESSER DETAIL. BY SUBMITTING A BID FOR THIS PROJECT, IT IS UNDERSTOOD THAT THE SUB CONTRACTOR AND MANUFACTURER AGREE TO WARRANTY / GUARANTY THE DETAILS SHOWN. ARCHITECT OF RECORD MAY, BUT IS NOT OBLIGATED TO, ACCEPT ANY PROPOSED CHANGES TO THE DETAILS SHOWN.
9. THE ROOFING CONTRACTOR IS TO PROVIDE ALL LABOR AND MATERIAL FOR A COMPLETE AND WATERTIGHT JOB WHICH IS FULLY WARRANTED / GUARANTEED BY THE MANUFACTURER AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. ANY DETAILS OR WORK REQUIRED FOR A COMPLETE JOB, BUT NOT SHOW NOR SPECIFIED BY THE CONTRACT DOCUMENTS, SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER. ANY ADDITIONAL LABOR AND MATERIAL REQUIRED TO MEET MANUFACTURER'S WARRANTY / GUARANTY REQUIREMENTS, BUT NOT INDICATED BY THE CONTRACT
DOCUMENTS, SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER.
10. ALL NEW CRICKETS/GUSSETS TO BE TAPERED ISO DOUBLE THE SLOPE OF ROOF(e.g 1/4" PER FOOT FOR 1/8" PER
FOOT ROOF SLOPE)
11. PROVIDE CRICKET BEHIND ALL ROOF CURBS GREATER THAN 24" AT HIGHER SLOPE.
12. ADDITIONAL DETAILS NOT KEYED ON ROOF PLAN MAY BE REFERENCED AND SHALL BE INSTALLED AS NECESSARY.
13. INSPECT STRUCTURAL ROOF DECK PRIOR TO INSTALLATION OF NEW ROOF ASSEMBLY. NOTIFY OWNER AND ENGINEER OF RECORD OF UNSATISFACTORY CONDITIONS. DO NOT PROCEED WITH ROOFING WORKING UNTIL UNSATISFACTORY CONDITIONS HAS BEEN CORRECTED IN A MANNER ACCEPTABLE TO OWNER. PREPARE ROOF
DECK SURFACE PER SPECIFICATION REQUIREMENTS.
14. ROOFING CONTRACTOR SHALL PROVIDE SHOP DRAWING FOR GUSSET/ CRICKET/ ROOF INSULATION LAYOUT FROM
ROOFING MANUFACTURER FOR ENGINEER OF RECORD TO REVIEW PRIOR TO INSTALLATION.
15. ALL CONDUITS, GAS LINES, AND CONDENSATE LINES SHALL BE SUPPORTED ON PREMANUFACTURED SUPPORTS BY MIRO OR APPROVED EQUAL. (EXACT CONDUIT AND GAS LINES NOT SHOWN ON ROOF PLAN.) CONTRACTOR SHALL
FIELD VERIFY ALL CONDUITS AND SUPPORT REQUIREMENTS PRIOR TO SUBMITTING BID.
16. ALL WORK RELATED TO ELECTRICAL CONDUIT PENETRATION SHALL BE PERFORMED BY LICENSED ELECTRICAL CONTRACTOR IN THE STATE WHERE WORK IS PERFORMED. ALL PENETRATION FLASHINGS SHALL BE BY ROOFING
CONTRACTOR.
17. PRIOR TO INSTALLATION OF NEW ROOF ASSEMBLY, CONTRACTOR SHALL IDENTIFY AREA WHERE ELECTRICAL CONDUITS ARE IN PROXIMITY TO TOP FLUTE OF DECK. CONTRACTOR SHALL AVOID MECHANICAL FASTENING INTO
DECK WHERE ELECTRICAL CONDUITS ARE IN PROXIMITY TO TOP FLUTE OF DECK.
ROOF DEMOLITION
18. ROOFING CONTRACTOR SHALL INCLUDE BUT NOT BE LIMITED TO THE REMOVAL OF ALL EXISTING MEMBRANES, WOOD BLOCKINGS, VAPOR RETARDANTS, INSULATION, FLASHING, FASTENERS, PAVERS, DRAINS & RELATED
MATERIALS DOWN TO THE STRUCTURAL DECK.
19. ROOFING CONTRACTOR SHALL TEMPORARILY REMOVE, PROTECT & STORE EXISTING METALS AND/OR OTHER
COMPONENTS TO REMOVE AND REPLACE ROOFING SYSTEMS.
20. REMOVE AND CLEAN MATERIALS FROM WALLS AND ROOF DECK TO PREPARE THE SURFACE TO RECEIVE NEW ROOF SYSTEM. DAMAGED OR DETERIORATED ROOF DECK UNCOVERED DURING ROOFING DEMOLITION SHALL BE DOCUMENTED BY THE ROOFING SUB CONTRACTOR, REPORTED TO ARCHITECT OF RECORD, IN WRITING AND
REPLACED ON A UNIT PRICE BASIS.
21. RAISE EXISTING ROOF TOP UNIT CURBS, GAS LINES AND ASSOCIATED CONNECTIONS AS REQUIRED TO ACCOMODATE NEW ROOF ASSEMBLY. ALL WORK IS TO BE PERFORMED BY LICENSED MECHANICAL CONTRACTOR IN THE STATE WHERE WORK IS PERFORMED. ALL ROOF TOP PENETRATIONS TO BE WATERTIGHT PER ROOF MANUFACTURER REQUIREMENTS. ALL ROOF FLASHINGS IS TO BE INSTALLED BY LICENSED ROOF CONTRACTOR.
22. LIMIT ROOFING SYSTEM REMOVAL TO AN AREA WHICH CAN BE MADE WATERTIGHT WITH THE INITIAL MEMBRANE AT
THE END OF EACH WORKING DAY OR SOONER AS REQUIRED DUE TO WEATHER.
23. CONTRACTOR SHALL ENSURE ROOF AND FLASHINGS REMAIN WATERTIGHT THROUGHOUT CONSTRUCTION.
24. THE ROOFING CONTRACTOR SHALL PHOTO DOCUMENT ALL EXISTING ROOFTOP , EXHAUST FANS, AND ANY OTHER EQUIPMENT PRIOR TO THE START OF WORK. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR OR REPLACE ANY EQUIPMENT FOUND TO BE MALFUNCTIONING OR INOPERABLE AFTER THE WORK, AT NO COST TO
THE OWNER, IF SUCH EQUIPMENT WAS NOT REPORTED PRIOR TO THE START OF WORK.
25. TEMPORARILY DISCONNECT AND RECONNECT ANY MECHANICAL/ELECTRICAL LINES AND EQUIPMENT AS NECESSARY TO DISPOSE OF THE ROOF SYSTEM AND RELATED MATERIAL. COORDINATE DISCONNECTION AND
RECONNECTION WITH OWNER.
26. THE ROOFING CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS WHICH INTERFERE WITH THE INSTALLATION OF THE NEW ROOF SYSTEM AND RELATED WORK. ALL SUCH EQUIPMENT AND ITEMS SHALL BE TEMPORARILY RE-ROUTED AS NECESSARY IF IT REQUIRED TO STAY IN SERVICE. ANY ITEMS NOT REQUIRED TO STAY IN SERVICE SHALL BE PROPERLY STORED BY THE SUB CONTRACTOR AND REINSTALLED AT THE COMPLETION OF THE WORK.
27. ALL ELECTRICAL, MECHANICAL AND PLUMBING WORK SHALL BE PERFORMED BY LICENSED CONTRACTORS. ALL REINSTALLED WORK SHALL BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER. ANY EXISTING WORK WHICH
DOES NOT CONFORM TO APPLICABLE CURRENT CODES SHALL BE REPORTED TO OWNER.
GENERAL NOTES PROJECT NOTES PROPERTY INFORMATION
ABBREVIATIONS
@ AT
Ø DIAMETER
" INCH
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS
EX. EXISTING
GA GAUGE
LOW. LOWER AREA
MAX. MAXIMUM
MIN. MINIMUM
N/A NOT APPLICABLE
O.C. ON CENTER
PART. PARTIAL
SIM. SIMILAR
TYP. TYPICAL
UPP. UPPER AREA
ASTM - AMERICAN SOCIETY FOR TESTING AND MATERIALS
U.L.- UNDERWRITERS' LABORATORIES
F.M - FACTORY MUTUAL OR FACTORY MUTUAL RESEARCH CORPORATION
SMACNA - SHEET METAL AND AIR CONDITIONING CONTRACTOR ASSOCIATION
A.I.A. - AMERICAN INSTITUTE OF ARCHITECTS
N.R.C.A. - NATIONAL ROOFING CONTRACTOR ASSOCIATION
I.B.C. - INTERNATIONAL BUILDING CODE, 2021
I.E.B.C. - INTERNATIONAL EXISTING BUILDING CODE, 2021
I.P.C. - INTERNATIONAL PLUMBING CODE, 2018 EDITION WITH 2020 GEORGIA STATE AMENDMENTS.
I.E.C.C.- INTERNATIONAL ENERGY CONSERVATION CODE, 2015 EDITION WITH 2020 GEORGIA STATE
AMENDMENTS AND SUPPLEMENTS
O.S.H.A. - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
NFPA - NATIONAL FIRE PREVENTION ASSOCIATION
REFERENCES
DETAIL REFERENCE
NUMBER
SHEET LOCATION
ELEVATION MARKER
SECTION MARKER
ENLARGED DETAIL
MARKER
MATCH LINE #/###
REVISION NUMBER
ELEVATION DATUM
NORTH ARROWN
SECTION
AutoCAD SHX Text X
166'-2" [50647.83]
352'-0" [107289.60]
60'-0" [18288.00]
5'
-1 0"
[5
.0
0]
'-6
.2
0]
31'-10" [9702.80]
9'
-2
0.
'-2
4.
ROOF AREA A
ROOF AREA H
ROOF AREA I
26'-0"
-5 '-0
+5 '-0
+10'-0"
-3'-0"
CONTROL JOINT
C O
N
TR
O L
JO
IN
T
ROOF AREA K
ROOF AREA J
ROOF AREA C
ROOF AREA D
ROOF AREA F
ROOF AREA E
ROOF AREA G
ROOF AREA B
ROOF AREA L
ROOF AREA M
COMMISSARY WAREHOUSE (N.I.C.)
LEGEND
ROOFTOP UNIT (RTU)
ROOF OUTLINE/EDGE VENT PIPE
EXHAUST FAN (EF)
HEATED VENT STACK (HVS)
C:\Users\marcella.staniek\Desktop\-deca-logo-outline-609359.png
HMP
DHJ, HMP
RR
24 MARCH 2022
ROOF REPLACEMENT/ REPAIR DESIGN
WRIGHTS-PATTERSON AFB
COMMISSARY BUILDING , OHIO
TETRA TECH
Louisville, Kentucky 40222
(502) 569-9007
Suite 245 2000 Warrington Way
IF DRAWING IS NOT 30" X 42", SCALE ACCORDINGLY.
PROJECT NUMBER:
DIRECTORATE OF FACILITIES
FT. LEE, VIRGINIA
DESIGN AND CONSTRUCTION DIVISION
LACKLAND AFB, TEXAS
DEFENSE COMMISSARY AGENCY
DESIGNED BY:
DRAWN BY:
SUBMITTED BY:
ENGINEER:
REVIEWED BY:
DRAWING NUMBER:
SOL NUMBER:
OF
DATE:
SHEET:
SEQUENCE
NUMBER:
SYMBOL DATE DESCRIPTION OF REVISIONSACTIOND O NO
100% SUBMISSION - FOR CONSTRUCTION
EA21MR05
This electronic drawing file is released under the authority of Bill Nieport, TX # 23653 and Tetra Tech, TX # BR 594 who maintains a hard copy of the original file. The user of this electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file. No person may make any modification to this electronic drawing file without the
Architect's express written permission.
PRELIMINARY:
FOR INTERIM REVIEW
NOT FOR
CONSTRUCTION,
BIDDING OR PERMIT
PURPOSES
DATE:
TX LICENSE:
ARCHITECT :
TT FIRM REG. NO.
DHJ
RR
DEMOLITION ROOF PLAN
A-1013
SCALE: 1/16" = 1'-0"
DEMOLITION ROOF PLAN
0 4' 8' 16'
SCALE: 1/8" = 1'-0"
TAPERED INSULATION
SHEET NOTES
WATER FLOW DIRECTION
1. DEMOLISH EXISTING GRAVEL BALLASTED BUILT UP AND MODIFIED ROOFS IN THEIR ENTIRETY. DEMOLISH ALL RELATED BASE FLASHING, FLASHING, COUNTER FLASHING, WOOD BLOCKING AND APPURTENANCES.
PATCH AND REPAIR REMAINING SURFACES FOR ROOF INSTALLATION, TYPICAL.
2. EXISTING VENTS, EQUIPMENT OR OTHER ROOFTOP PENETRATIONS TO REMAIN, U.N.O. REMOVE ANY PIPE
BOOTS, FLASHING, AND SEALANTS AROUND EQUIPMENT. RAISE TO RECEIVE NEW ROOFING AND
INSULATION SYSTEM.
3. REMOVE AND PROPERLY DISPOSE OF EXISTING ACCESS LADDER IN ITS ENTIRETY. PATCH AND REPAIR
ROOF AS REQUIRED.
4. REMOVE EXISTING COUNTERFLASING/ REGLET IN ITS ENTIRETY. PATCH AND REPAIR AS REQUIRED.
5. EXISTING ROOF TOP EQUIPMENT IS NO LONGER IN USE. REMOVE IN ITS ENTIRETY. PATCH AND REPAIR AS
REQUIRED.
6. REMOVE EXISTING ROOF DRAIN
7. REMOVE AND PROPERLY DISPOSE OF EXISTING BUILDING PERIMETER COUNTER FLASHING.
8. REMOVE ALL ABANDONED CURBS AND PIPE PENETRATIONS AND INSTALL NEW SUBSTRATE TO MATCH
EXISTING.
PRIMAY ROOF DRAIN (PRD)
26'-0" 21'-0" 26'-0"
16'-0"
19'-0"
12'-0" 12'-0"
12'-0"
N
GENERAL ROOF DEMOLITION NOTES
1. CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION NECESSARY FOR INSTALLATION OF NEW
WORK.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE INSTALLATION
OF THE NEW ROOFING SYSTEM. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO
PROCEEDING.
3. REMOVE EXISTING ROOF SYSTEM, INSULATION, WOOD BLOCKING AND FLASHING DOWN TO
STRUCTURAL DECK. VERIFY THAT DECK SURFACE AND PROJECT CONDIITONS ARE READY TO
RECEIVE THE NEW WORK. IF EXISTING DECK IS SHOWING SIGNS OF RUST OR FAILURE, PLEASE
NOTIFY ARCHITECT PRIOR TO PROCEEDING.
4. THE BUILDING IS TO BE OCCUPIED DURING DEMOLITION AND PLACEMENT OF THE NEW
ROOFING SYSTEM. THE OWNER IS TO HAVE COMPLETE USE OF THE FACILITIES EXCEPT FOR
LIMITED AREAS AT LIMITED PERIODS OF TIME.
5. CONTRACTOR SHALL PRESERVE AND PROTECT ALL EXISTING UTILITIES, DUCTS AND
EQUIPMENT TO REMAIN. DEMOLISH ABANDONED CONDENSATION LINES AND ROOF
PENETRATIONS TO BELOW DECK, TYPICAL
6. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN, INSTALLATION AND MONITORING OF ALL
TEMPORARY FACILITIES AND STRUCTURES.
1 1
1 1
CONTROL JOINT
ACCESS LADDER
ROOF HATCH
4 4
6 6
6 6
7 7
TYP.
TYP.
TYP. TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
6 6
ROOF AREA A
ROOF AREA H
ROOF AREA I
26'-0"
-5 '-0
+5 '-0
+10'-0"
-3'-0"
CONTROL JOINT
C O
N
TR
O L
JO
IN
T
ROOF AREA K
ROOF AREA J
ROOF AREA C
ROOF AREA D
ROOF AREA F
ROOF AREA E
ROOF AREA G
ROOF AREA B
ROOF AREA L
ROOF AREA M
COMMISSARY WAREHOUSE (N.I.C.)
C:\Users\marcella.staniek\Desktop\-deca-logo-outline-609359.png
HMP
DHJ, HMP
RR
24 MARCH 2022
ROOF REPLACEMENT/ REPAIR DESIGN
WRIGHTS-PATTERSON AFB
COMMISSARY BUILDING , OHIO
TETRA TECH
Louisville, Kentucky 40222
(502) 569-9007
Suite 245 2000 Warrington Way
IF DRAWING IS NOT 30" X 42", SCALE ACCORDINGLY.
PROJECT NUMBER:
DIRECTORATE OF FACILITIES
FT. LEE, VIRGINIA
DESIGN AND CONSTRUCTION DIVISION
LACKLAND AFB, TEXAS
DEFENSE COMMISSARY AGENCY
DESIGNED BY:
DRAWN BY:
SUBMITTED BY:
ENGINEER:
REVIEWED BY:
DRAWING NUMBER:
SOL NUMBER:
OF
DATE:
SHEET:
SEQUENCE
NUMBER:
SYMBOL DATE DESCRIPTION OF REVISIONSACTIOND O NO
100% SUBMISSION - FOR CONSTRUCTION
EA21MR05
This electronic drawing file is released under the authority of Bill Nieport, TX # 23653 and Tetra Tech, TX # BR 594 who maintains a hard copy of the original file. The user of this electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file. No person may make any modification to this electronic drawing file without the
Architect's express written permission.
PRELIMINARY:
FOR INTERIM REVIEW
NOT FOR
CONSTRUCTION,
BIDDING OR PERMIT
PURPOSES
DATE:
TX LICENSE:
ARCHITECT :
TT FIRM REG. NO.
DHJ
RR
NEW ROOF PLAN
A-1024
SCALE: 1/16" = 1'-0"
NEW ROOF PLAN
0 4' 8' 16'
SCALE: 1/8" = 1'-0"
2 2
6 2
A-501
A-501
A-501
A-501
A-501
A-501
A-501
A-501
A-501
A-501UPP
UPP
A-501
A-501
A-301
A-501
A-501
LEGEND
ROOFTOP UNIT (RTU)
ROOF OUTLINE/EDGE VENT PIPE
EXHAUST FAN (EF)
HEATED VENT STACK (HVS)
STRUCTURAL SLOPE
SHEET NOTES
WATER FLOW DIRECTION
1. FURNISH AND INSTALL NEW ROOFING SYSTEM (GRANULE SURFACED, TWO -PLY MODIFIED BITUMEN ON COVER BOARD OVER INSULATION) PER MANUFACTURERS SPECIFICATIONS. PROVIDE MANUFACTURERS
FLASHINGS, METAL FLASHINGS AND ACCESSORIES FOR COMPLETE INSTALLATION.
2. INSTALL NEW DRAINS AND RECEIVERS - MATCH INSULATION THICKNESS
3. INSTALL NEW BUILDING PERIMETER EAVE / METAL EDGE DETAIL.
4. PAINT MISCELLANEOUS STEEL: PAINT ALL EXISTING EXPOSED METAL APPURTENANCES WITH COLD
APPLIED ZINC GALVANIZED COATING.
5. FURNISH AND INSTALL NEW OSHA COMPLIANT ROOF ACCESS LADDERS FROM UPPER ROOF TO LOWER ROOF (DO NOT PENETRATE ROOF) AT EXISTING LOCATIONS AND AT LOCATIONS WHICH WILL ALLOW
ACCESS TO ALL OTHER ROOF AREAS.
6. FURNISH AND INSTALL WALK BOARDS/PADS - SEE A-104. REFER TO SPECIFICATIONS FOR WALKPAD
REQUIREMENTS.
7. FURNISH AND INSTALL APPROPRIATE SUPPORTS FOR GAS, ELECTRICAL, AND CONDENSATE LINES, AS
SPECIFIED.
8. FURNISH AND INSTALL NEW CONTROL JOINT COVER.
9. FURNISH AND INSTALL APPROPRIATE SUPPORTS FOR GAS, ELECTRICAL AND CONDENSATE LINES, AS
SPECIFIED.
10. STRAIGHTEN THE MISALIGNED CONTROL JOINT AND CONTROL JOINT COVER. REPAIR AS NEEDED
PRIMAY ROOF DRAIN (PRD)
GENERAL NOTES
1. COORDINATE RE-ROOFING OPERATIONS TO PREVENT WATER INFILTRATION INTO BUILDING
DURING CONSTRUCTION.
2. COORDINATE ANY MECHANICAL FASTENERS WITH ELECTRICAL CONDUIT THAT MAY BE
INSTALLED, CONTRACTOR WILL BE RESPONSIBLE TO REPAIR ANY EXISTING ELECTRICAL
DAMAGED DURING RE-ROOFING OPERATIONS.
3. STAGGER JOINTS BETWEEN LAYERS OF POLYISO INSULATION. NO JOINTS BETWEEN LAYERS
SHOULD ALIGN.
4. VERIFY THAT DECK SURFACE AND PROJECT CONDITIONS ARE READY TO RECEIVE THE NEW
WORK. IF EXISTING DECK IS SHOWING SIGNS OF RUST OR FAILURE, PLEASE NOTIFY ARCHITECT
PRIOR TO PROCEEDING.
CONTROL JOINT
ACCESS LADDER
ROOF HATCH WALKWAY PADS
ELEVATION CHANGE
TYP.
TYP.
TYP.
TYP.
3 3
TYP.
TYP. TYP.
TYP.
TAPERED INSULATION
A-501
A-501
A-501
A-501LOW
N
26'-0"
'-7
'-7
'-7
'-7
'-7
'-7
'-7
'-7
15'-7"15'-7"
15'-7"15'-7"
'-7
1 8"
'-7 1 4"
'-7
'-7
9' -7
9'
-7
9' -7
9'
-7
'-5
'-5
5'-2"
TYP
5'-2"
TYP
3'-2"
TYP
3'-10"
TYP
ROOF AREA A
ROOF AREA B
ROOF AREA D
ROOF AREA H
ROOF AREA I
11 11
3 3
ROOF AREA C
ROOF AREA E
ROOF AREA F ROOF AREA G
ROOF AREA J
ROOF AREA K
ROOF AREA L
15'-7"15'-7"
3 3
15'-7"15'-7"
ROOF AREA M
COMPONENTS AND CLADDING WIND PRESSURES (UNFACTORED PSF)
LOAD TYPE
3 1
ROOF ZONES
UNFACTORED LOADS
FACTORED ASD LOADS
FACTORED LOADS w/
2.0 SF
-76.7
-46.1
-92.2
BASIC WIND SPEED (V ULT)= 107MPH
RISK CATEGORY II
EXPOSURE CATEGORY C
ENCLOSURE CLASSIFICATION - ENCLOSED STRUCTURE
ROOF AREAS B & C: h = 21' = 0
-56.3
-33.8
-67.6
-42.7
-25.6
-51.2
COMPONENTS AND CLADDING WIND PRESSURES (UNFACTORED PSF)
LOAD TYPE
3 1'
ROOF ZONES
UNFACTORED LOADS
FACTORED ASD LOADS
FACTORED LOADS w/
2.0 SF
-80.1
-48.1
-96.1
ROOF AREAS A & D - G : h = 26' = 0
-58.8
-35.3
-70.6
-25.6
-15.4
-30.7
-44.6
-26.8
-53.5
COMPONENTS AND CLADDING WIND PRESSURES (UNFACTORED PSF)
LOAD TYPE
3 1'
ROOF ZONES
UNFACTORED LOADS
FACTORED ASD LOADS
FACTORED LOADS w/
2.0 SF
-75.0
-45.0
-90.0
ROOF AREAS H & I: h = 19' > 7
-24.0
-14.4
-28.8
-41.7
-25.0
-50.0
-55.1
-33.1
-66.1
COMPONENTS AND CLADDING WIND
PRESSURES (UNFACTORED PSF)
LOAD TYPE
ROOF ZONES
UNFACTORED LOADS
FACTORED ASD LOADS
FACTORED LOADS w/
2.0 SF
-71.7
-43.0
-86.0
ROOF AREAS J - M:
h = 12' = 0
1'
-24.5
-14.7
-29.4
LEGEND
ROOF
OUTLINE/PARAPET
C:\Users\marcella.staniek\Desktop\-deca-logo-outline-609359.png
HMP
DHJ, HMP
RR
24 MARCH 2022
ROOF REPLACEMENT/ REPAIR DESIGN
WRIGHTS-PATTERSON AFB
COMMISSARY BUILDING , OHIO
TETRA TECH
Louisville, Kentucky 40222
(502) 569-9007
Suite 245 2000 Warrington Way
IF DRAWING IS NOT 30" X 42", SCALE ACCORDINGLY.
PROJECT NUMBER:
DIRECTORATE OF FACILITIES
FT. LEE, VIRGINIA
DESIGN AND CONSTRUCTION DIVISION
LACKLAND AFB, TEXAS
DEFENSE COMMISSARY AGENCY
DESIGNED BY:
DRAWN BY:
SUBMITTED BY:
ENGINEER:
REVIEWED BY:
DRAWING NUMBER:
SOL NUMBER:
OF
DATE:
SHEET:
SEQUENCE
NUMBER:
SYMBOL DATE DESCRIPTION OF REVISIONSACTIOND O NO
100% SUBMISSION - FOR CONSTRUCTION
EA21MR05
This electronic drawing file is released under the authority of Bill Nieport, TX # 23653 and Tetra Tech, TX # BR 594 who maintains a hard copy of the original file. The user of this electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file. No person may make any modification to this electronic drawing file without the
Architect's express written permission.
PRELIMINARY:
FOR INTERIM REVIEW
NOT FOR
CONSTRUCTION,
BIDDING OR PERMIT
PURPOSES
DATE:
TX LICENSE:
ARCHITECT :
TT FIRM REG. NO.
DHJ
RR
WIND ZONE ROOF PLAN
A-1035
SCALE: 1/16" = 1'-0"
WIND ZONE ROOF PLAN
1 2
WIND ZONE 1
WIND ZONE 3
WIND ZONE 11
WIND ZONE 2
0 4' 8' 16'
SCALE: 1/8" = 1'-0"
N
AutoCAD SHX Text Q = 0 = 0 °
AutoCAD SHX Text Q = 0 = 0 °
AutoCAD SHX Text Q > 7 > 7 °
Q = 0 = 0 °
ROOF AREA A
ROOF AREA H
ROOF AREA I
26'-0"
-5 '-0
+5 '-0
+10'-0"
-3'-0"
CONTROL JOINT
C O
N
TR
O L
JO
IN
T
ROOF AREA K
ROOF AREA J
ROOF AREA C
ROOF AREA D
ROOF AREA F
ROOF AREA E
ROOF AREA G
ROOF AREA B
ROOF AREA L
ROOF AREA M
COMMISSARY WAREHOUSE (N.I.C.)
C:\Users\marcella.staniek\Desktop\-deca-logo-outline-609359.png
HMP
DHJ, HMP
RR
24 MARCH 2022
ROOF REPLACEMENT/ REPAIR DESIGN
WRIGHTS-PATTERSON AFB
COMMISSARY BUILDING , OHIO
TETRA TECH
Louisville, Kentucky 40222
(502) 569-9007
Suite 245 2000 Warrington Way
IF DRAWING IS NOT 30" X 42", SCALE ACCORDINGLY.
PROJECT NUMBER:
DIRECTORATE OF FACILITIES
FT. LEE, VIRGINIA
DESIGN AND CONSTRUCTION DIVISION
LACKLAND AFB, TEXAS
DEFENSE COMMISSARY AGENCY
DESIGNED BY:
DRAWN BY:
SUBMITTED BY:
ENGINEER:
REVIEWED BY:
DRAWING NUMBER:
SOL NUMBER:
OF
DATE:
SHEET:
SEQUENCE
NUMBER:
SYMBOL DATE DESCRIPTION OF REVISIONSACTIOND O NO
100% SUBMISSION - FOR CONSTRUCTION
EA21MR05
This electronic drawing file is released under the authority of Bill Nieport, TX # 23653 and Tetra Tech, TX # BR 594 who maintains a hard copy of the original file. The user of this electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file. No person may make any modification to this electronic drawing file without the
Architect's express written permission.
PRELIMINARY:
FOR INTERIM REVIEW
NOT FOR
CONSTRUCTION,
BIDDING OR PERMIT
PURPOSES
DATE:
TX LICENSE:
ARCHITECT :
TT FIRM REG. NO.
DHJ
RR
WALK PAD ROOF PLAN
A-1016
SCALE: 1/16" = 1'-0"
WALK PAD ROOF PLAN
LEGEND
ROOFTOP UNIT (RTU)
ROOF OUTLINE/EDGE VENT PIPE
EXHAUST FAN (EF)
HEATED VENT STACK (HVS)
TAPERED INSULATION
SHEET NOTES
WATER FLOW DIRECTION
1. ROOFING SYSTEM WALKWAY PAD, TYPICAL.
PRIMAY ROOF DRAIN (PRD)
GENERAL NOTES
1. WALKPADS ARE INDICATED ON THIS PLAN FOR CLARITY.
2. INSTALL WALKPADS AT PERIMETER OF RTU UNITS, ROOF HATCH, AND ROOF EQUIPMENT; TOP
AD BOTTOM OF LADDERS AS INDICATED.
CONTROL JOINT
ACCESS LADDER
ROOF HATCH WALKWAY PADS
0 4' 8' 16'
SCALE: 1/8" = 1'-0"
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
1. MEMBRANE SEAMS SHOULD NOT INTERSECT DRAIN CLAMPING RING.
2. REFER TO DETAIL A/A-501 FOR ROOF COMPOSITION.
3. INSTALL NEW INSULATION WRAP BELOW THE DECK.
NEW MODIFIED BITUMEN PLY SHEET
MEMBRANE PLIES, METAL FLASHING AND STRIPPING SHEET
EXTEND UNDER CLAMPING RING
NEW CAST-IRON DRAIN BOWL
NEW DECK CLAMP
NEW CLAMPING RING
EXISTING METAL DECK
NOTES:
NEW MODIFIED BITUMEN MEMBRANE
STRIPPING SHEET
NEW 36'' SQUARE MINIMUM, 4LB. LEAD SET IN COMPATIBLE ROOF CEMENT AND
FOLDED INTO DRAIN (PRIME TOP SURFACE BEFORE STRIPPING)
NEW DRAIN STRAINER
SBS MODIFIED BITUMEN GRANULE SURFACED CAP
SHEET
APPROX. 4"
APPROVED FIRE RETARDANT CANT
ROOFING FASTENERS
AT 8" O.C
ROOF MEMBRANE (2-PLY) FLASHING SYSTEM
PER MANUFACTURER.
ROOF MEMBRANE BASE FLASHING(2-PLY MIN.)
AT WOOD WALLS
MECHANICALLY FASTEN APPROVED MANUFACTURER
BASE FLASHING PLY TO MASONRY/WOOD SURFACE @ 12"
O.C ALL DIRECTION PRIOR TO INSTALLATION OF TWO PLY
BASE FLASHING.
TERMINATION BAR
AT 12" O.C
NEW MODIFIED BITUMEN ROOF SYSTEM
NEW COVERBOARD
NEW INSULATION
EXISTING ROOF DECK
N
2 E
2 E
NEW EDGE METAL & EXTENSION (AS REQUIRED)
NEW WOOD BLOCKING TO MATCH HEIGHT OF INSULATION
NEW VAPOR RETARDER
NOTES:
1. REFER TO NRCA DETAIL UL-25.
2. REMOVE EXISTING WOOD BLOCKING WHERE DETERIORATED AND REPLACE WITH NEW.APPLY SAME
WOOD BLOCKING THICKNESS AROUND ENTIRE BUILDING PERIMETER.
3. APPLY NEW WOOD BLOCKING TO MATCH THE HEIGHT OF THE EXISTING INSULATION.
4. MEMBRANE BENEATH CLEAT SHALL EXTEND A MINIMUM OF 1" BEYOND THE WOOD BLOCKING.
5. USE FACE EXTENDER WHEN EDGE METAL DOES NOT COVER WOOD BLOCKING. FACE EXTENDER AND
FACE EXTENDER CLEAT SHALL BE FASTENED TO WOOD BLOCKING. REFER TO NRCA DETAIL UL-34.
6. REFER TO DETAIL A/A-501 FOR ROOF ASSEMBLY.
7. ALL SHEET METAL IS TO BE INSTALLED PER SMACNA GUIDELINES.
8. GRANULES MUST BE EMBEDDED WHEN THERMALLY FUSING GRANULE SURFACED CAP SHEET.
8" M
AX
NEW EDGE METAL
CLEAT
OVERLAY OR THERMAL BARRIER IS REQUIRED
NEW MODIFIED BITUMEN BASE FLASHING
NEW MODIFIED BITUMEN ROOFING
NEW ROOF INSULATION
NEW WOOD BLOCKING, AS REQUIRED
EXISTING CONDITIONS
NEW COVERBOARD
NEW CANT
NEW BASE SHEET
NEW MODIFIED BITUMEN ROOFING
NEW ROOF INSULATION
NEW COVERBOARD
NEW CANT
NEW BASE SHEET
E E
E
N
NEW CONTROL JOINT COPING
NEW COPING CLEAT
NOTES:
1. REFER TO DETAIL A/A-501 FOR ROOF COMPOSITION.
2. REFER TO DETAIL 3/A-501 FOR BASE FLASHING.
3. APPLY NEW WOOD BLOCKING AS NEEDED TO MAINTAIN A MINIMUM 8" BASE FLASHING HEIGHT ABOVE THE FINISHED ROOF.
NEW CAP NAILS EVERY 8" O.C.
NEW VAPOR RETARDER
NEW THERMAL BARRIER
NEW VAPOR RETARDER
NEW THERMAL BARRIER
NEW CONTROL JOINT CURB
NEW COPING
NEW ROOFING AS SPECIFIED
NEW GRAVEL-STOP FASCIA
CONTROL JOINT CLOSURE.
REFER TO DETAIL 10/A503.
CONTROL JOINT CLOSURE
3"
3"
4" 3"
3"
3" C1 C2
C4
C3
2"3" 3"
8" (C
.J . H
EI
G
H T, V .I.
F.
1'-31 2"
6" 6"
6" (E
D G
E M
ET
AL
H
EI
G H
T, V
.I.
F.
6"
3"
3"
3"
A1
A2 A3
B1 B3
B2
(QNTY 2, 1 OPP. HAND)
(QNTY 2, 1 OPP. HAND)
C1 C2
B1
B1
B2
B2
A1
A2
A3
C1
ROOFING NOT
SHOWN FOR CLARITY
3"
3"
3"
6"
8"
5"
5"
8"
A1 A2
A3A4
B1
A2 A3
A4
B1
GRAVEL-STOP FASCIA CLOSURE
3"
3"
4" 3"
3"
3" C1 C1
GRAVEL-STOP FASCIA CLOSURE.
REFER TO DETAIL 5/A502.
NEW GRAVEL-STOP FASCIA
NEW WOOD BLOCKING
NEW PVC SHEATHING
A1
C2 C4
C3
C2
NEW MODIFIED BITUMEN BASE FLASHING
NEW COUNTERFLASHING
NEW TERMINATION BAR
NEW CANT
NEW COVERBOARD
NEW INSULATION
EX. CURB COVER
NOTES:
1. REMOVE EXISTING WOOD BLOCKING WHERE DETERIORATED AND REPLACE
WITH NEW.
2. APPLY NEW WOOD BLOCKING TO MAINTAIN 8" MINIMUM HEIGHT ABOVE THE
NEW ROOF.
3. REFER TO DETAIL 3/A-501 FOR BASE FLASHING.
4. REFER TO DETAIL A/A-501 FOR ROOF COMPOSITION.
3"
EXISTING CONDITIONS
NEW MODIFIED BITUMEN ROOFING
NEW ROOF INSULATION
NEW COVERBOARDNEW CANT
NEW BASE SHEET
E
N
NEW WOOD BLOCKING
NEW COPING CLEAT
NOTES:
1. REFER TO DETAIL A/A-501 FOR ROOF COMPOSITION.
2. REFER TO DETAIL 3/A-501 FOR BASE FLASHING.
3. INSIDE LEG OF COPING SHALL NOT EXCEED 3".
4. APPLY NEW WOOD BLOCKING AS NEEDED TO MAINTAIN A MINIMUM 8" BASE
FLASHING HEIGHT ABOVE THE FINISHED ROOF.
5. USE FACE EXTENDER WHEN EDGE METAL DOES NOT COVER WOOD BLOCKING.
FACE EXTENDER AND FACE EXTENDER CLEAT SHALL BE FASTENED TO WOOD
BLOCKING. REFER TO NRCA DETAIL UL-34.
5" M
AX
NEW CAP NAILS EVERY 8" O.C.
EXISTING CONDITIONS
NEW TAPERED EDGE STRIP
NEW VAPOR RETARDER
NEW THERMAL BARRIER
NEW COPING
Down
FLAT DRIVE
CLEAT DETAIL
5" M
AX
3" M
AX
SURFACE MOUNTED COUNTERFLASHING
NEW CLOSURE
COPING NEW COPING
EX. PARAPET
9"
3"
PARAPET
WIDTH 3"
3"
6" 1"
B2 B1 B3
B4 B5 B6
A1
B1
B2
B3
A1
NEW 2-PLY SBS MODIFIED BITUMEN
GRANULE SURFACED ROOF SYSTEM
NEW ADHERED COVERBOARD
NEW ADHERED INSULATION
EXISTING METAL ROOF DECK
2" (R-25 MIN.)
0"
NEW MECHANICALLY FASTENED INSULATION
NEW OVERLAY OR THERMAL BARRIER AS REQUIRED
NEW VAPOR RETARDER
ROOFING MEMBRANE
TERMINATION BAR
NOTES:
1. TERMINATION BAR MUST BE CUT AT INSIDE AND OUTSIDE CORNERS. DO
NOT BEND AROUND CORNERS.
2. TERMINATION BAR MUST BE FASTENED WITHIN 1" MAX. OF ALL SECTION
ENDS.
3. INSTALL METAL WORK IN ACCORDANCE WITH CURRENT SMACNA
RECOMMENDATIONS.
WALLS / CURBS
(MASONRY/ CONCRETE
SUBSTRATE ONLY)
CONTINUOUS BEAD OF SEALANT
COUNTERFLASHING
FASTENER 12" O.C. MAX.
FASTENER 12" O.C. MAX.
USE APPROPRIATE BONDING ADHESIVE
CONTINUOUS BEAD OF SEALANT
CONTINUOUS BEAD OF SEALANT
TAPERED EDGE NEW INSULATION
COVERBOARD (AS REQUIRED)
EXISTING CONDITIONS
NEW STRAINER BASKET
COMPRESSION RING
MULTI-PURPOSE MB FLASHING CEMENT
12" (305 mm)
1" (25 mm)
MAX
1/2" (13 mm) MIN
SEE NOTES
NOTES:
1. REFER TO MANUFACTURER'S SPECIFICATIONS FOR MOST
CURRENT INFORMATION.
2. WHEN DRAIN SUMP EXCEEDS 1:12, THE USE OF A DRAIN INSERT
IS RECOMMENDED.
3. THE MEMBRANE SHOULD EXTEND A MIN OF 1/2" (13 mm) BEYOND
THE CLAMPING RING AND SHOULD NOT BE SMALLER THAN THE
DIAMETER OF THE LEADER PIPE.
4. IF A FIELD SEAM IS BETWEEN 6" - 9" (152 mm - 229 mm) OF DRAIN
COMPRESSION RING, A SMOOTH SBS MODIFIED BITUMEN
TARGET PATCH IS REQUIRED.
5. NO SEAM CAN BE LESS THAN 6" (152 mm) FROM THE CLAMPING
RING.
30" X 30" (762 mm X 762 mm) MINIMUM, 2.5 LB - 4 LB (12 - 19 kg/m) LEAD OR COPPER FLASHING SET ON
THE BASE PLY IN COMPATIBLE FLASHING CEMENT
(PRIME TOP SURFACE BEFORE STRIPPING)
NEW VAPOR RETARDER
NEW THERMAL BARRIER
BASE AND INTERPLY SHEETS AS REQUIRED
(METAL DECK)
MODIFIED BITUMEN GRANULE SURFACED CAP SHEET
C:\Users\marcella.staniek\Desktop\-deca-logo-outline-609359.png
HMP
DHJ, HMP
RR
24 MARCH 2022
ROOF REPLACEMENT/ REPAIR DESIGN
WRIGHTS-PATTERSON AFB
COMMISSARY BUILDING , OHIO
TETRA TECH
Louisville, Kentucky 40222
(502) 569-9007
Suite 245 2000 Warrington Way
IF DRAWING IS NOT 30" X 42", SCALE ACCORDINGLY.
PROJECT NUMBER:
DIRECTORATE OF FACILITIES
FT. LEE, VIRGINIA
DESIGN AND CONSTRUCTION DIVISION
LACKLAND AFB, TEXAS
DEFENSE COMMISSARY AGENCY
DESIGNED BY:
DRAWN BY:
SUBMITTED BY:
ENGINEER:
REVIEWED BY:
DRAWING NUMBER:
SOL NUMBER:
OF
DATE:
SHEET:
SEQUENCE
NUMBER:
SYMBOL DATE DESCRIPTION OF REVISIONSACTIOND O NO
100% SUBMISSION - FOR CONSTRUCTION
EA21MR05
This electronic drawing file is released under the authority of Bill Nieport, TX # 23653 and Tetra Tech, TX # BR 594 who maintains a hard copy of the original file. The user of this electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file. No person may make any modification to this electronic drawing file without the
Architect's express written permission.
PRELIMINARY:
FOR INTERIM REVIEW
NOT FOR
CONSTRUCTION,
BIDDING OR PERMIT
PURPOSES
DATE:
TX LICENSE:
ARCHITECT :
TT FIRM REG. NO.
DHJ
RR
TYPICAL ROOF DETAILS
A-5017
SCALE: 3" = 1'-0"2 ROOF DRAIN ASSEMBLY
SCALE: 3" = 1'-0"3 TYP. BASE FLASHING DETAIL
SCALE: 3" = 1'-0"1 TYP. ROOF EDGE DETAIL
SCALE: 3" = 1'-0"5 TYP. CONTROL JOINT DETAIL
SCALE: 1 1/2" = 1'-0"6 TYP CONTROL JOINT CLOSURE DETAIL
SCALE: 1 1/2" = 1'-0"8 TYP GRAVEL STOP CLOSURE DETAIL
SCALE: 3" = 1'-0"4 TYP. CURB DETAIL
SCALE: 3" = 1'-0"7 TYP PARAPET DETAIL
SCALE: 1 1/2" = 1'-0"9 TYP COPING CLOSURE DETAIL
SCALE: 3" = 1'-0"A NEW ROOF ASSEMBLY
''A''
SEE TABLE
ON SM-9
UP TO
1 1/2''
3'' MIN.
FLANGE
EMBEDDED EDGE (A-TYPE)
FASTEN APPROX. 3''
TO 6'' O.C.
STAGGERED WITH
CORROSION-RESISTANT,
BARBED, ANNULAR
RING OR SCREW
SHANK NAIL. LENGTH
TO ACHIEVE APPROX.
1 1/4'' PENETRATION
INTO NAILER
APPROX. 3
/4''
CLEAT INFORMATION
TYPICAL CLEAT ENGAGEMENT
3"
FASTEN NEAR LOWER BREAK FOR
INCREASED UPLIFT RESISTANCE
FASTEN AT APPROX. 6" O.C. WITH
CORROSION-RESISTANT BARBED,
ANNULAR RING OR SCREW SHANK NAIL.
LENGTH TO ACHIEVE APPROX. 1 1/4"
PENETRATION INTO NAILER
CLEAT THICKNESS TO BE ONE GAUGE HEAVIER THAN
PERIMETER EDGE METAL
ROOF SIDE
FACE SIDE
L-TYPE PERIMETER EDGE METAL
SHEET METAL SET IN SEALANT
L-TYPE PERIMETER EDGE METAL
3" M
IN.
BEND FLANGE AT
ROOF SIDE
OPTION
APPROPRIATE FASTENERS
APPROX. 3" TO 6" O.C.
STAGGER PATTERN VARIES
PER ROOF SYSTEM
APPROPRIATE FASTENERS
APPROX. 3" TO 6" O.C.
STAGGER PATTERN VARIES
PER ROOF SYSTEM
SHEET METAL SET IN SEALANT
3" M
IN.
III - NRCA SM-17 L-TYPE PERIMETER EDGE METAL
SCALE: 3" = 1'-0"10
TYP. TERMINATION WITH SURFACE
MOUNTED COUNTERFLASING AND
TERMINATION BAR
SCALE: N.T.S.11 ROOF DRAIN
ONE-PIECE SURFACE-MOUNTED COUNTERFLASHING
1/2" MIN.
1" MIN.
4" M
IN
2" WIDE CLIP APPROX. 30" O.C.
APPROPRIATE FASTENERS
APPROX. 24" O.C.
ONE-PIECE SHEET-METAL
COUNTERFLASHING
SECTION
SEALANT OR
ELASTOMERIC
TAPE
APPROPRIATE SEALANT
TOLLED TO FACILITATE
WATER RUNOFF
APPROXIMATELY 2''-WIDE
BOND BREAKER MATERIAL
1/4'' GAP BETWEEN ADJACENT
PIECES OF MEMBRANE-
COATED METAL
MEMBRANE JOINT COVER
INSTALLED PER
MANUFACTURERS'
RECOMMENDATIONS
FLANGE APPROXIMATELY
4'' MIN. WIDE
4'' WIDE MEMBRANE FLASHING
WELDED TO
MEMBRANE-COATED METAL
EDGE
MEMBRANE-COATED METAL
4''
I- NRCA SM-15 A-TYPE EDGE METAL W OVERLAP
AutoCAD SHX Text A/A-501
A/A-501
HMP
DHJ, HMP
RR
24 MARCH 2022
ROOF REPLACEMENT/ REPAIR DESIGN
WRIGHTS-PATTERSON AFB
COMMISSARY BUILDING , OHIO
TETRA TECH
Louisville, Kentucky 40222
(502) 569-9007
Suite 245 2000 Warrington Way
IF DRAWING IS NOT 30" X 42", SCALE ACCORDINGLY.
PROJECT NUMBER:
DIRECTORATE OF FACILITIES
FT. LEE, VIRGINIA
DESIGN AND CONSTRUCTION DIVISION
LACKLAND AFB, TEXAS
DEFENSE COMMISSARY AGENCY
DESIGNED BY:
DRAWN BY:
SUBMITTED BY:
ENGINEER:
REVIEWED BY:
DRAWING NUMBER:
SOL NUMBER:
OF
DATE:
SHEET:
SEQUENCE
NUMBER:
SYMBOL DATE DESCRIPTION OF REVISIONSACTIOND O NO
100% SUBMISSION - FOR CONSTRUCTION
EA21MR05
This electronic drawing file is released under the authority of Bill Nieport, TX # 23653 and Tetra Tech, TX # BR 594 who maintains a hard copy of the original file. The user of this electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file. No person may make any modification to this electronic drawing file without the
Architect's express written permission.
PRELIMINARY:
FOR INTERIM REVIEW
NOT FOR
CONSTRUCTION,
BIDDING OR PERMIT
PURPOSES
DATE:
TX LICENSE:
ARCHITECT :
TT FIRM REG. NO.
DHJ
RR
TYPICAL ROOF DETAILS
A-5028
SCALE: N.T.S.2 SHEET-METAL STACK VENT
OPTIONAL: METAL LINER
AND INSULATION
COMPATIBLE ROOF
CEMENT OR
COMPATIBLE SEALANT
AT FLASHING-TO-
MEMBRANE JUNCTURE
4'' MIN. FLANGE
SET IN COMPATIBLE
ROOF CEMENT¾
PRIME FLANGE
BEFORE STRIPPING.
SHEET-METAL RAIN
COLLAR
SHEET-METAL FLASHING
POLYMER-MODIFIED
BITUMEN MEMBRANE
STRIPPING SHEET
APPROPRIATE SEALANT
(E.G., POLYURETHANE)
DRAWBAND
8' ' M
IN
IM
U M
FL
A
S H
IN
G
H E
IG
H
T
SEALANT
POLYMER-MODIFIED
BITUMEN PLY SHEET
POLYMER-MODIFIED
BITUMEN CAP SHEET
APPROX. 4"
SCALE: N.T.S.3 PLUMBING VENT
APPROX. 4''
TOP OF FLASHING CAPPED OR
ROLLED INTO PIPE
APPROXIMATELY 1''
SOFT METAL PIPE FLASHING¾
SEE NOTE 1
PLUMBING VENT STACK
POLYMER-MODIFIED BITUMEN
MEMBRANE STRIPPING SHEET
COMPATIBLE ROOF CEMENT OR
COMPATIBLE SEALANT AT
PENETRATION-
TO-MEMBRANE JUNCTURE
POLYMER-MODIFIED BITUMEN
CAP SHEET
SET FLANGE IN COMPATIBLE
ROOF CEMENT¾PRIME FLANGE
BEFORE STRIPPING.
8' ' M
IN
IM
U M
FL
A
S H
IN
G
H E
IG
H
T
POLYMER-MODIFIED BITUMEN
PLY SHEET
SCALE: N.T.S.4
BASE FLASHING AT EXISTING
PREFABRICATED METAL CURB
EXTENDED FIELD PLIES
ABOVE TOP OF CANT
FASTENERS APPROX.
8'' O.C.¾MIN. TWO
FASTENERS PER SIDE
REMOVABLE SHEET-METAL
COUNTERFLASHING¾
SEE NOTES 8 AND 9
GASKETED FASTENER¾MIN.
TWO FASTENERS PER SIDE
CURB
WOOD NAILER
ROOFTOP EQUIPMENT
FRAME
BACKER FOR TORCH-
APPLIED SYSTEMS,
SELF-ADHERING SHEET WITH
SEALED LAPS
MEMBRANE FLASHING
SHEET ADHERED TO
BACKER
APPROX. 4''
REMOVEABLE
WEATHERPROOF
SHEET-METAL PIPE
PENETRATION HOOD¾
REFER TO SPECIFICATION
& 13/A-502
FLANGE SET
IN COMPATIBLE
ROOF CEMENT¾
PRIME FLANGE BEFORE
STRIPPING
POLYMER-MODIFIED
BITUMEN PLY
SHEET
POLYMER-MODIFIED
BITUMEN MEMBRANE
STRIPPING SHEET
POLYMER-MODIFIED
BITUMEN CAP SHEET
APPROX. 4''
2 X 6 MIN. WOOD NAILER
ATTACHED TO SUBSTRATE¾
OVERALL THICKNESS TO MATCH
INSULATION
SLOPE PIPES DOWN
AND AWAY FROM
HOOD
INSULATE VOID (NOT
SHOWN FOR CLARITY)
MIN. TWO
FASTENERS PER SIDE
SCALE: N.T.S.5
BASE FLASHING AT SHEET-METAL HOOD FOR
PIPING/MULTIPLE CONDUITS THROUGH ROOF DECK
CANT
2 X 6 MIN.
WOOD NAILER
ATTACHED TO
SUBSTRATE¾OVERALL
THICKNESS TO MATCH
INSULATION
OPTIONAL: EXTENDED
FIELD PLIES ABOVE
TOP OF CANT
FASTENERS APPROX.
8'' O.C.
GASKETED
FASTENERS¾MIN. TWO
FASTENERS PER SIDE
SEALING MATERIAL
WOOD CURB
ROOFTOP EQUIPMENT
FRAME
SHEET-METAL RECEIVER
WITH REMOVABLE
COUNTERFLASHING¾
SEE NOTES 7 AND 8
EXTENDED BACKER
BACKER (SELF-ADHERING SHEET,
MOPPED POLYMER- MODIFIED BITUMEN
BASE SHEET OR TWO TYPE IV PLIES
MOPPED) WITH SEALED LAPS
TORCH-APPLIED
MEMBRANE FLASHING
SHEET ADHERED TO
BACKER¾SEE NOTE 4
APPROX. 4''
SCALE: N.T.S.6
BASE FLASHING AT EXISTING
WOOD CURB
SCALE: N.T.S.7
SHEET-METAL STACK VENT (LIQUID APPLIED)
SCALE: N.T.S.8
PLUMBING VENT (LIQUID APPLIED)
SCALE: N.T.S.9 PIPE PENETRATION
SCALE: N.T.S.1
METAL LINER AND INSULATION
LIQUID-APPLIED
REINFORCED
FLASHING
SHEET-METAL
FLASHING MIN. 8''
ABOVE ROOF
MEMBRANE
SHEET-METAL RAIN
COLLAR
APPROPRIATE
SEALANT (E.G.,
POLYURETHANE)
DRAWBAND
4' ' M
IN
IM
U
M SEALANT
APPROX. 4"
FL
AS
H
IN
G H
EI
G
H T
PLUMBING VENT STACK
LIQUID-APPLIED REINFORCED
FLASHING
4' ' M
IN
IM
U M
FL
A
S H
IN
G
H E
IG
H
T
APPROX. 6''
SEAL AROUND PLUMBING
VENT WITH COMPATIBLE
SEALANT
LIQUID-APPLIED
REINFORCED FLASHING
APPROX. 4"
4' ' M
IN
IM
U M
FL
AS
H
IN
G H
EI
G
H T
SEAL AROUND PENETRATION
WITH COMPATIBLE SEALANT
LIQUID-APPLIED REINFORCED FLASHING
FLANGED CABLE PENETRATION FLASHING
APPROX. 4''
APPROX. 4''
CABLE PENETRATION
NEW SHEET
METAL PLATE
EXISTING CONDITIONS
EXISTING DECKING
EXISTING CONDITIONS
NEW DECKING
EXISTING DECKING
LARGE OPENING DECKING REPAIR DETAIL
SMALL OPENING DECKING REPAIR DETAIL
1' 4"
4"
4"
4"
4"
4"
4" 4"1'
6" 6"
ZONE NO. 1
ZONE NO. 2
ZONE NO. 3
8-1/2"
3"
1/4"
4-1/2"
7"
24"
22 1/8"
Ø9/16"
27"
26"
6" 4'
TY
P.
AS
R
EQ
'D
1/8" MOLDED
POLYURETHANE
SAFETY CAPS
1 1/4" ALUMINUM
SQUARE TUBING
HANDRAILS
3" X 1" X 1/8"
ALUMINUM TUBULAR
SIDERAIL
F
T.
M
AX
.12
" T
YP
2 1/4" SERRATED
ALUMINUM TREAD
6"
SIDE VIEW FRONT VIEW
BRACKET DETAIL
TOP VIEW
NOTES:
1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
2. DO NOT SCALE DRAWING.
3. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES ONLY. THIS DRAWING MAY NOT BE USED
FOR CONSTRUCTION.
4. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE
REVIEWED AND APPROVED BY THE PRODUCT MANUFACTURER TO BE CONSIDERED ACCURATE.
WALK PAD WELDED TO
ROOF MEMBRANE
PIPE SUPPORT
SET IN SEALANT
NOTES
1. EXISTING WELDS ARE ASSUMED TO BE A MINIMUM 1/2" DIAMETER.
ENHANCE ATTACHMENT AS SHOWN. IF EXISTING WELDS ARE LESS
THAN 1/2" DIAMETER, INSTALL ALL NEW FASTENERS IN 36/4 PATTERN.
2. NEW FASTENERS ARE MINIMUM #10 TEK SCREWS WITH A NOMINAL
HEAD DIAMETER OF 0.415 INCHES.
3. EXISTING DECKING ATTACHMENT DOES NOT HAVE TO BE ENHANCED IF
THE EXISTING WELDS ARE A MINIMUM OF 1/2" DIAMETER, AND THE
PATTERN IS 36/4 OR GREATER. IF EXISTING WELDS ARE LESS THAN
1/2" DIAMETER, INSTALL ALL NEW FASTENERS IN 36/4 PATTERN.
C:\Users\marcella.staniek\Desktop\-deca-logo-outline-609359.png
HMP
DHJ, HMP
RR
24 MARCH 2022
ROOF REPLACEMENT/ REPAIR DESIGN
WRIGHTS-PATTERSON AFB
COMMISSARY BUILDING , OHIO
TETRA TECH
Louisville, Kentucky 40222
(502) 569-9007
Suite 245 2000 Warrington Way
IF DRAWING IS NOT 30" X 42", SCALE ACCORDINGLY.
PROJECT NUMBER:
DIRECTORATE OF FACILITIES
FT. LEE, VIRGINIA
DESIGN AND CONSTRUCTION DIVISION
LACKLAND AFB, TEXAS
DEFENSE COMMISSARY AGENCY
DESIGNED BY:
DRAWN BY:
SUBMITTED BY:
ENGINEER:
REVIEWED BY:
DRAWING NUMBER:
SOL NUMBER:
OF
DATE:
SHEET:
SEQUENCE
NUMBER:
SYMBOL DATE DESCRIPTION OF REVISIONSACTIOND O NO
100% SUBMISSION - FOR CONSTRUCTION
EA21MR05
This electronic drawing file is released under the authority of Bill Nieport, TX # 23653 and Tetra Tech, TX # BR 594 who maintains a hard copy of the original file. The user of this electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file. No person may make any modification to this electronic drawing file without the
Architect's express written permission.
PRELIMINARY:
FOR INTERIM REVIEW
NOT FOR
CONSTRUCTION,
BIDDING OR PERMIT
PURPOSES
DATE:
TX LICENSE:
ARCHITECT :
TT FIRM REG. NO.
DHJ
RR
TYPICAL ROOF DETAILS
A-5039
SCALE: 1 1/2" = 1'-0"1 TYP. DECK CLOSURE DETAIL
SCALE: 3" = 1'-0"2 DECK FASTENING DETAIL
SCALE: N.T.S.3 TYPICAL ADHESIVE PATTERN DETAIL
SCALE: N.T.S.4 FIXED ACCESS LADDER
SCALE: N.T.S.5 TYP. PIPE SUPPORT DETAIL
SCALE: N.T.S.6 WALKPADS OVER ADHERED MEMBRANE
WALK PAD WELDED TO
ROOF MEMBRANE
CONTINUOUS WELD AROUND EDGE
OF WALKPAD MEMBRANE
(MIN.2" GAP BETWEEN WALK PADS)
SBS MODIFIED MEMBRANE IN
BITUMEN TO MATCH THE
MEMBRANE
WALKWAY PAD ADHERED
TO ROOF MEMBRANE
NEW 2-PLY SBS MODIFIED BITUMEN
GRANULE SURFACED ROOF SYSTEM
| Sheets and Views |
| 1395.007 WP AFB_8-11-2021-G-001 |
| 1395.007 WP AFB_8-11-2021-G-002 |
| 1395.007 WP AFB_8-11-2021-A101 |
| 1395.007 WP AFB_8-11-2021-A102 |
| 1395.007 WP AFB_8-11-2021-A103 |
| 1395.007 WP AFB_8-11-2021-A104 |
| 1395.007 WP AFB_8-11-2021-A501 |
| 1395.007 WP AFB_8-11-2021-A502 |
| 1395.007 WP AFB_8-11-2021-A503 |
File details come from the government source that posted it. Updated .